Fan Optimization for Power Tools using HyperWorks
-
Upload
altair-engineering -
Category
Technology
-
view
894 -
download
2
Transcript of Fan Optimization for Power Tools using HyperWorks
![Page 1: Fan Optimization for Power Tools using HyperWorks](https://reader035.fdocuments.in/reader035/viewer/2022062300/559b38511a28abf73e8b4621/html5/thumbnails/1.jpg)
1
Fan Optimization for Power Tools using Hyper Works
(Combination of Acusolve, HyperMorph, HyperStudy & SimLab)
by
Raúl Cano
![Page 2: Fan Optimization for Power Tools using HyperWorks](https://reader035.fdocuments.in/reader035/viewer/2022062300/559b38511a28abf73e8b4621/html5/thumbnails/2.jpg)
Agenda
• Introduction (Company & Products)
• Hammer description
• Problem description
• Fan Optimization Process
• Results
![Page 3: Fan Optimization for Power Tools using HyperWorks](https://reader035.fdocuments.in/reader035/viewer/2022062300/559b38511a28abf73e8b4621/html5/thumbnails/3.jpg)
3
Introduction (Company & Products)
Stanley Black & Decker - DeWalt
DEWALT today is the leading brand of professional power tools in North America and
in the last 5 years the fastest growing power tool brand in the world.
Compact Hammers Mid Size Hammers Big Size Hammers
![Page 4: Fan Optimization for Power Tools using HyperWorks](https://reader035.fdocuments.in/reader035/viewer/2022062300/559b38511a28abf73e8b4621/html5/thumbnails/4.jpg)
Agenda
• Introduction (Company & Products)
• Hammer description
• Problem description
• Fan Optimization Process
• Results
![Page 5: Fan Optimization for Power Tools using HyperWorks](https://reader035.fdocuments.in/reader035/viewer/2022062300/559b38511a28abf73e8b4621/html5/thumbnails/5.jpg)
Hammer description
![Page 6: Fan Optimization for Power Tools using HyperWorks](https://reader035.fdocuments.in/reader035/viewer/2022062300/559b38511a28abf73e8b4621/html5/thumbnails/6.jpg)
Agenda
• Introduction (Company & Products)
• Hammer description
• Problem description
• Fan Optimization Process
• Results
![Page 7: Fan Optimization for Power Tools using HyperWorks](https://reader035.fdocuments.in/reader035/viewer/2022062300/559b38511a28abf73e8b4621/html5/thumbnails/7.jpg)
Problem description
Fan
Heat generating parts
Heat generating parts
All this heat generating parts must
be cool down by the air flow produced
by the fan inside the hammer
High resistance – small gaps
![Page 8: Fan Optimization for Power Tools using HyperWorks](https://reader035.fdocuments.in/reader035/viewer/2022062300/559b38511a28abf73e8b4621/html5/thumbnails/8.jpg)
8
Problem description
Volume Flow 4Kg. Hammer
Inlet
Outlet
Inlet FanOutlet Fan
InletOutlet
Inlet FanOutlet Fan
Inlet
Outlet
Inlet Fan
Outlet Fan
0
5
10
15
20
25
Fans
Vo
lum
e F
low
(l/
s)
Fan 1 Fan 2 Fan 3
Fan 1
Fan 2
![Page 9: Fan Optimization for Power Tools using HyperWorks](https://reader035.fdocuments.in/reader035/viewer/2022062300/559b38511a28abf73e8b4621/html5/thumbnails/9.jpg)
Problem description
9
0,00
100,00
200,00
300,00
400,00
500,00
600,00
0,00 0,05 0,10 0,15 0,20 0,25 0,30 0,35 0,40 0,45 0,50
Po
wer
in [
W]
Torque in [Nm]
If the Air Flow Is increased,
the Power out, produced by the motor
could be also increased
Motor power out
for the Motor G59x30
480 W Power out
with low air flow
500 W Power out
with high air flow
![Page 10: Fan Optimization for Power Tools using HyperWorks](https://reader035.fdocuments.in/reader035/viewer/2022062300/559b38511a28abf73e8b4621/html5/thumbnails/10.jpg)
Problem description
Motor power out
air flow power out influence
(Not a real case)
![Page 11: Fan Optimization for Power Tools using HyperWorks](https://reader035.fdocuments.in/reader035/viewer/2022062300/559b38511a28abf73e8b4621/html5/thumbnails/11.jpg)
Agenda
• Introduction (Company & Products)
• Hammer description
• Problem description
• Fan Optimization Process
• Results
![Page 12: Fan Optimization for Power Tools using HyperWorks](https://reader035.fdocuments.in/reader035/viewer/2022062300/559b38511a28abf73e8b4621/html5/thumbnails/12.jpg)
12
Fan Optimization Process
Workflow optimization Process (Altair GmbH)
![Page 13: Fan Optimization for Power Tools using HyperWorks](https://reader035.fdocuments.in/reader035/viewer/2022062300/559b38511a28abf73e8b4621/html5/thumbnails/13.jpg)
Fan Optimization Process
FEM Model for a
4 Kg Hammer
Inlet
Outlet
Baffle
Fan
![Page 14: Fan Optimization for Power Tools using HyperWorks](https://reader035.fdocuments.in/reader035/viewer/2022062300/559b38511a28abf73e8b4621/html5/thumbnails/14.jpg)
14
Fan Optimization Process
CAD Parts
CAE Parts
Baffle Fan
Fan
Simplified Baffle
Key Parts
![Page 15: Fan Optimization for Power Tools using HyperWorks](https://reader035.fdocuments.in/reader035/viewer/2022062300/559b38511a28abf73e8b4621/html5/thumbnails/15.jpg)
Fan Optimization Process
Morph Volume & Handles
Morph Elements
Simplified symmetric model for the 4 Kg. Hammer
one fin model from 17 fins in total
![Page 16: Fan Optimization for Power Tools using HyperWorks](https://reader035.fdocuments.in/reader035/viewer/2022062300/559b38511a28abf73e8b4621/html5/thumbnails/16.jpg)
16
Inlet Outlet
Fan Baffle
Angle Vertical
Fin Height
Curvature
Fin length
Fin Height 2
Curvature 2
Thickness
Fan Optimization Process
Simplified Model
Symmetric Model
for the 4 Kg Hammer.
Faster way
to evaluate the most
influence parameters.
![Page 17: Fan Optimization for Power Tools using HyperWorks](https://reader035.fdocuments.in/reader035/viewer/2022062300/559b38511a28abf73e8b4621/html5/thumbnails/17.jpg)
Agenda
• Introduction (Company & Products)
• Hammer description
• Problem description
• Fan Optimization Process
• Results
![Page 18: Fan Optimization for Power Tools using HyperWorks](https://reader035.fdocuments.in/reader035/viewer/2022062300/559b38511a28abf73e8b4621/html5/thumbnails/18.jpg)
Results
• Until now we got an increase of 10% in the
mass flow, it is possible to increase this
value.
• New process and understanding of
HyperMorph-Acusolve-HyperStudy
combination. New optimization parameters
are possible: Fan Torque optimization, fins
gearbox optimization, temperature
distribution.