Fan Drives in Mobile Hydraulic...

34
This is Peak Performance! TM Fan Drives in Mobile Hydraulic Applications Matt Kronlage Fan Drive Applications Engineer [email protected]

Transcript of Fan Drives in Mobile Hydraulic...

Page 1: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

© Power Point Template 1 – turolla OCG © Power Point Template 1 – turolla OCG

This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications

Matt Kronlage Fan Drive Applications Engineer

[email protected]

Page 2: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

2 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications

• Introduction • Cooling System Overview • Power Sources • Heat Sources • Cooling Sources • Fan Operation • Fan Drive Systems Overview • Hydraulic Fan Drive Systems and Capabilities • Advanced Hydraulic Systems

Page 3: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

3 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Introduction

Why would I want to use a fan in my mobile machine?

• Operator Climate Control – Heating, cooling, filtering, positive pressure cabs

• Useful machine work – Venting, Drying, Cleaning

•Removing Waste Heat

Page 4: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

4 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Why do we need fan drives for cooling?

100% fuel energy

mechanical power for useful, productive, work

10%-25%

35% heat

exhaust pipe

35% heat

engine cooling

and accessory

30% mechanical power at engine

flywheel

Page 5: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

5 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Introduction

Turbo Charge Air

Hydraulic Fluid

Engine Water Jacket

AC Refrigerant

Transmission Fluid

Power Electronics

EGR Gases

Ambient Air

Page 6: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

6 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Fan Operation

𝑃2 = 𝑃1 ∗ 𝑘 ∗ 𝑛2𝑛1

3

𝑇2 = 𝑇1 ∗ 𝑘 ∗ 𝑛2𝑛1

2

Page 7: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

8 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Fan Operation

𝑃2 = 𝑃1 ∗ 𝑘 ∗ 𝑛2𝑛1

3

2700 3300

Page 8: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

9 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Fixed Ratio Mechanical Fan Drive Operation

Page 9: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

10 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Fan Power vs. Fan Speed

0.0

5.0

10.0

15.0

20.0

25.0

30.0

1000 1200 1400 1600 1800 2000 2200 2400

Engine Speed (rpm)

Pow

er, H

p

Mechanical Fan Power

Mechanical Input Power

Belts are efficient, why change? Fan Power Law = K x (engine speed)³

Overcooling =Power Wasted

Page 10: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

11 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Fixed Ratio Mechanical Fan Drive Operation

Page 11: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

12 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Break free from the fixed ratio!

Fan speed control independent of

engine speed and proportional to

cooling requirement!!!

Page 12: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

13 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Fan Operation vs. Engine Speed

Fan

Spee

d [r

pm]

Pres

sure

[bar

]; Po

wer

[kW

]

Engine Speed [rpm]

Page 13: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

14 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Power and Energy Savings

So what if I save power on this fan drive system?

• Fan system is not producing useful work (parasitic loss) • Saving power on cooling leaves more power for useful work • Saving power on cooling saves fuel and reduces operating

cost

Page 14: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

15 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Power and Energy Savings

• 200 hp machine • 30 hp fan (15% of Engine Power) • Fuel Cost: $3.50/gal • Specific fuel consumption .3518 lb./hp-hr • 7.3 lb/gal of diesel fuel • Operating days/year: 180 days/year • Operating hours/day: 8 hours/day • 10% decrease in average fan speed (33.1% power savings) • 9.93 hp saved on average

yr

gallbgal

yearday

dayhrhp

hrhplb /2412$50.3$*

3.7*180*8*

193.9*3518.

=⋅

⋅⋅⋅⋅⋅

Page 15: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

16 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Fan Power as a Function of Temperature

essEffectivenCoolingTTTT

MaxAmbientCoolant

ActualAmbCoolant _=−−

@ Vehicle Maximum Heat

Rejection

105°F (42°C) takes 60% of Full Power

( )3max_

_ essEffectivenCoolingP

P FanFan =

Fan

Pow

er R

equi

rem

ent (

% o

f ra

ted

)

Page 16: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

17 This is Peak Performance! TM

+=

b

cbc N

NLwLw 10log)50(

15% Increase in Fan Speed

dBLwLw

LwLw

bc

bc

3115.1log)50( 10

+=

+=

3dB Increase in Fan Noise

doubles the noise level to the

human ear European Noise Legislation:

Fan Drives in Mobile Hydraulic Applications Fan Noise vs. Fan Speed

Page 17: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

18 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Noise Legislation

Page 18: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

19 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Noise Legislation

OSHA Noise Exposure Limits: Sound Level

(dBA) Exposure

Limit (hours/day)

90 8 92 6 95 4 97 3 100 2

* Employee notifications are required for environments with sound levels greater than 85 dBA

Page 19: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

20 This is Peak Performance! TM

-12

-10

-8

-6

-4

-2

0

2

4

6

8

-40% -30% -20% -10% 0% 10% 20% 30%

Sound Power Level Change as a Function of Fan Speed Change

Change in Fan Speed, (%)

Chan

gein

Sou

nd P

ower

Leve

l, (%

)

Fan Drives in Mobile Hydraulic Applications Noise Legislation

Page 20: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

21 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Proportional Fan Drive Types

• Mechanical Continuously Variable Transmissions • Viscous Clutch Drives • Electric Generator/Motor Drives • Variable Pitch Fan Blades

•Hydraulic Fan Drive Systems

Page 21: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

22 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Hydraulic System Advantages

• Compliments other hydraulic machine functions – Propel – Work function

• Flexible connections allow for optimal cooler location • Reversing is an option • Fan off function

Page 22: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

23 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Basic Hydraulic Fan Drive System

Page 23: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

24 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Speed to Pressure Relationship

• Follows the fan torque curve – Motor pressure differential increases with the square of fan speed

(ideal) – By controlling pressure difference across the motor, fan speed can be

controlled

2700 3300

Page 24: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

25 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Fail-safe systems

What happens when the control system fails?

The system must default to a full fan speed state

Page 25: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

26 This is Peak Performance! TM

Motor schematic

Fan Drives in Mobile Hydraulic Applications Fixed Pump Fixed Motor System

Up to 35 hp

Page 26: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

27 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Variable Pump Fixed Motor System

10 to 50 hp

Page 27: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

28 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Over Center Pump Fixed Motor System

30 hp and up

Page 28: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

29 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Reversing Function

•Why would I use a reversing fan?

– Agricultural, Construction, Forestry – Removes contamination to operate cooler at highest

efficiency – Reduce manual blowout frequency – Remove washout water from radiator without getting

into machine

Page 29: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

30 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Fixed Pump Fixed Motor Reversing System

Page 30: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

31 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Variable Pump Fixed Motor Reversing System

Page 31: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

32 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications Distributed Cooling

Divide and Conquer!!

Hydraulics

Transmission

A/C

CAC

Power Electronics

Engine Coolant

EGR

Page 32: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

33 This is Peak Performance! TM

• Benefits: – Locate coolers closer to their heat sources – Smaller coolers can fit in tighter places – Each cooler can be cooled according to its need

•Prevents overcooling of individual cooling systems •Better thermal control of individual systems

Fan Drives in Mobile Hydraulic Applications Distributed Cooling

Page 33: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

34 This is Peak Performance! TM

Hydraulic Distributed Cooling Systems Tier 3 Tier 4 I {Tier 4 I Tier 4 I}

43” 50”

Distributed Fan Drive System

20 HP delta 22 HP

30”

16”

Fan Power

Power

From

engine

14 cc 21 cc 11 cc 8 cc

12.5 HP Max 23 HP Max 9.6 HP Max 1.3 HP Max

3.4 HP Avg 6.3 HP Avg 2.6 HP Avg 0.3 HP Avg

22 HP Max 42 HP Max 17.5 HP Max 2.5 HP Max

8.1 HP Avg. 15.9 HP Avg 6.8 HP Avg 1.0 HP Avg 7.8 HP

delta 8.1 HP

Page 34: Fan Drives in Mobile Hydraulic Applicationsfluidpowerjournal.com/wp-content/uploads/2012/12/11_fan... · 2012. 12. 11. · Fan Drives in Mobile Hydraulic Applications Why do we need

35 This is Peak Performance! TM

Fan Drives in Mobile Hydraulic Applications

Thank You

Matt Kronlage

Fan Drive Product Applicatons Engineer

TurollaOCG [Member of the Sauer-Danfoss Group]

[email protected]

www.TurollaOCG.com