Fan details

download Fan details

of 5

Transcript of Fan details

  • 7/29/2019 Fan details

    1/5

    Torrino assiale ad anello - motore UNEL-MECRing axial roof fans - IEC motor

    APPLICATIONSROOF-AM line is designed to extract large volumes of air in roofinstallations, without long ducts. For instance: ventilation ofindustrial buildings (factories, warehouses etc.), stock farms andelectrical equipments etc.

    RANGEThis line consists of 7 sizes with impeller from 500 up to 1000 mm.

    ADVANTAGESThis line is characterized by the wide round shaped nozzles in bothinlet and outlet, warranty of reduced noise level and high efficiency.Besides these fans allow the effective operation either in exhaustor supply duty. Electric motor is easily accessible for wiring and

    maintenance operations, manufactured according to internationalstandards assuring reliability and the long-term economic recoveryof the unit simply repairing or replacing the motor itself.

    CONSTRUCTIONRing casing with double wide round shaped nozzle, and baseresistant to the atmospheric agents.Upper cover in techno-polymer resistant to the atmosphericagents.Protection grid on outlet side in steel rod, manufactured accordingto UNI 9219.Inside protection grid (in lack of shutter or ducts).Impeller with high efficiency airfoil blades. Hub in die-castaluminum alloy. Balancing according to UNI ISO 1940. Variablepitch angle in still position.Asynchronous electric motor, protection IP 55, Class F insulated,service S1, construction according to IEC/EEC (UNEL-MEC)standard.Arrangement 4 (impeller directly coupled to motor shaft).

    TECHNICAL SPECIFICATIONSROOF-AM standard

    Conveyed air: clean, not abrasive.Temperature of conveyed air: -20C / +50C.Voltage: three phase version (T) 400V-3Ph.

    Single phase version (M) 230V-1Ph.Frequency: 50Hz.Working as exhaust fan.

    ACCESSORIESInlet gravity shutter, only for exhaust fans (GS-RO).Service switch.Outer terminal box (OTB).Support base for corrugate roof covering (SB).Silencer (SIL-RO).Counter base (CB).Inlet grid (PG) mandatory for use in free air.Service switch (SW).

    ON REQUESTIntake versions.Versions with air flow 100% reversible (ROOF-REV).Versions with three phase double polarity electric motor.Versions with casing and base in stainless steel or aluminum.Explosion proof versions (Roof-AM Atex)Versions with metal sheet cover.

    APPLICAZIONII torrini serie ROOF-AM sono destinati ad impieghi in cui necessitanograndi portate daria, in applicazioni a tetto, senza lunghecanalizzazioni. Ad esempio: ventilazione di edifici industriali(stabilimenti, magazzini), allevamenti, sala macchine, ecc.

    GAMMALa serie costituita da 7 grandezze con diametro girante da 500a1000 mm.

    PECULIARITLa serie ROOF-AM caratterizzata dalla presenza di imbocchi adampio raggio di curvatura, sia all'ingresso che all'uscita dell'aria, iquali garantiscono massima silenziosit ed elevati rendimenti aeraulici,

    inoltre essi consentono l'efficace utilizzo del torrino come estrattoreo come immissore. Il motore facilmente raggiungibile sia pereffettuare il primo collegamento elettrico sia per esigenze dimanutenzione. Il motore costruito seguendo standard internazionaligarantendo cos affidabilit ed a lungo termine un economicorecupero del ventilatore semplicemente riparando o sostituendo ilmotore stesso.

    COSTRUZIONEConvogliatore ad anello con doppio bordo ad ampio raggio dicurvatura e base dancoraggio in lamiera dacciaio, protetta controgli agenti atmosferici.Cappello in tecnopolimero resistente agli agenti atmosferici.Rete antivolatile ed antinfortunistica esterna, realizzata a normeUNI EN 294 in filo dacciaio e protetta contro gli agenti atmosferici.Rete di protezione interna (in assenza di serranda o canalizzazione)Girante ad alto rendimento con pale a profilo alare, ad angolodi calettamento variabile da fermo. Mozzo in fusione d'alluminio.Equilibratura secondo norme UNI ISO 1940.Motore elettrico asincrono a corrente alternata, protezione IP55, isolamento Cl F, servizio S1, costruzioneconforme alle specifiche norme IEC/EEC (UNEL-MEC).Esecuzione 4 (accoppiamento diretto con girante a sbalzo).

    SPECIFICHE TECNICHEROOF-AM standard

    Aria convogliata: pulita o leggermente polverosa, non abrasiva.Temperatura aria convogliata: -20C / +50CTensione dalimentazione: versione trifase (T) 400V-3Ph

    versione monofase (M) 230V-1PhFrequenza: 50Hz.Funzionamento in estrazione.

    ACCESSORISerranda a gravit, solo in estrazione (GS-RO).Interruttore di servizio.Morsettiera esterna (OTB).Basi d'appoggio su coperture ondulate (SB).Silenziatore (SIL-RO).Controbase a murare (CB).Rete lato girante (PG) obbligatoria nellutilizzo a bocca libera.Interruttore di servizio (SW).

    A RICHIESTAVersioni per funzionamento in immissione.Versioni con flusso dellaria effettivamente reversibile (ROOF-REV) .Versioni con motore elettrico a doppia polarit.Versioni con convogliatore e base in acciaio inossidabile o alluminio.Versioni ATEX (Roof-AM Atex).Versioni con cappello in metallo.

    66

    ROOF-AMROOF-AM

  • 7/29/2019 Fan details

    2/5

    ROOF-AM Prestazioni

    Performances

    Modello Portata - Flow rate Pm In max Mot. Lp

    Model (m3/h) (kW) (A) (H) dB(A)

    504 T 7.200 0,55 1,6 80 60564 T 10.500 0,75 2 80 61634 T 14.000 1,1 2,8 90S 66

    4 poli/poles(1500 rpm) - trifase/three-phases(3Ph-400V 50Hz)

    1 mm H2O= 9,8 Pa

    Modello Portata - Flow rate Pm In max Mot. Lp

    Model (m3/h) (kW) (A) (H) dB(A)

    808B T 16.500 0,75 2,3 100 57908A T 18.800 0,75 2,3 100 571008A T 22.500 1,1 3,4 100L 60

    8 poli/poles(750 rpm) - trifase/three-phases(3Ph-400V 50Hz)

    Modello Portata - Flow rate Pm In max Mot. Lp

    Model (m3/h) (kW) (A) (H) dB(A)

    506 T 5.100 0,18 0,7 71 49566 T 6.900 0,25 1 71 52

    636A T 9.500 0,37 1,3 80 57

    636B T 10.500 0,55 1,8 80 59716A T 12.500 0,75 2,2 90S 59716B T 16.000 1,1 3 90 61806 T 20.000 1,5 4 100 62

    906 T 25.000 1,5 4 100 631006 T 30.000 2,2 5 112 66

    6 poli/poles(1000 rpm) - trifase/three-phases(3Ph-400V 50Hz)

    8.000

    16

    7.0006.0005.000

    2

    0

    6

    4

    12

    8

    10

    14

    636A

    17.000 19.00012.00010.0009.000 15.000

    716A

    22.000 24.000 26.000

    806

    29.000 31.000

    906 1006

    Q(m3/h)

    636B

    716B

    67

    6

    3

    1

    4

    2

    5

    6.000 8.000 10.000 12.000

    0

    13.000 14.000 21.000 23.00016.000 19.000

    8

    9

    908A1008A

    Ps(mm

    H2O)

    808B

    26.000

    Q(m3/h)

    504

    0

    10

    4.0003.000 5.000 6.000 12.0007.000 8.000 9.000 14.000 16.000

    2

    4

    6

    8

    12

    14

    16

    564

    634

    Q(m3/h)

    Ps(mm

    H2O)

    Ps(mm

    H2O)

    566

    506

  • 7/29/2019 Fan details

    3/5

    ROOF-AM Rumorosit

    Noise level

    Livello Pressione Sonora Lp dB(A) 6m

    Sound Pressure Level Lp dB(A) 6m

    80

    70

    60

    50

    40

    30

    20

    10

    063 125 250 500 1k 2k 4k 8k Total

    Hz

    dB(A)

    36

    5155

    60 61 59 5651

    66

    ROOF-AM 1006

    80

    70

    60

    50

    40

    30

    2010

    0

    dB(A)

    23

    4347 47

    53 5549 47

    59

    ROOF-AM 716 A

    63 125 250 500 1k 2k 4k 8k TotalHz

    80

    70

    60

    50

    40

    30

    20

    10

    0

    dB(A)

    27

    46

    56 5454

    5452 44

    61

    ROOF-AM 564

    63 125 250 500 1k 2k 4k 8k TotalHz

    80

    70

    60

    5040

    30

    20

    10

    0

    dB(A)

    31

    46 5657 60

    6357

    49

    66

    ROOF-AM 634

    63 125 250 500 1k 2k 4k 8k TotalHz

    80

    70

    60

    50

    40

    30

    20

    10

    0

    d

    B(A)

    22

    37

    47 4551 54 48

    40

    57

    ROOF-AM 636 A

    63 125 250 500 1k 2k 4k 8k TotalHz

    80

    70

    60

    50

    40

    30

    20

    10

    0

    dB(A)

    31

    4549

    56 55 53 5045

    60

    ROOF-AM 1008 A

    63 125 250 500 1k 2k 4k 8k Total

    Hz

    80

    70

    60

    50

    40

    30

    20

    10

    0

    dB(A)

    27

    4246

    51 52 50 4742

    57

    ROOF-AM 908 A

    63 125 250 500 1k 2k 4k 8k Total

    Hz

    80

    70

    60

    50

    40

    30

    20

    10

    0

    dB(A)

    32

    4751

    56 57 5552

    47

    62

    ROOF-AM 806

    63 125 250 500 1k 2k 4k 8k TotalHz

    80

    70

    60

    50

    40

    30

    20

    10

    0

    dB(A)

    33

    4852

    57 58 56 5348

    63

    ROOF-AM 906

    63 125 250 500 1k 2k 4k 8k TotalHz

    80

    70

    60

    50

    40

    30

    20

    10

    0

    dB(A) 46 48 53 53 53 53 52 52

    60

    ROOF-AM 504

    63 125 250 500 1k 2k 4k 8k TotalHz

    Attenzione: il livello di pressione sonora riferito ad una misurazione onnidirezionale in campo libero a 6 m dal ventilatore con aspirazionecanalizzata e mandata libera.Attention: sound pressure level is measured in free field at 6 m from the fan, in any direction, with ducted inlet and free outlet.

    80

    70

    60

    50

    40

    30

    2010

    0

    dB(A)

    23

    4347 47

    53 5549 47

    59

    ROOF-AM 636 B

    63 125 250 500 1k 2k 4k 8k TotalHz

    80

    70

    60

    50

    40

    30

    20

    10

    0

    dB(A)

    3337

    4751 52 50 47 42

    57

    ROOF-AM 808 B

    63 125 250 500 1k 2k 4k 8k Total

    Hz

    80

    70

    60

    50

    40

    30

    2010

    0

    dB(A)

    31

    49 5156 57 55

    5247

    61

    ROOF-AM 716 B

    63 125 250 500 1k 2k 4k 8k TotalHz

    68

    80

    70

    60

    50

    40

    30

    20

    10

    0

    d

    B(A)

    2630

    39

    44 45 43

    40 35

    49

    ROOF-AM 506

    63 125 250 500 1k 2k 4k 8k TotalHz

    80

    70

    60

    50

    40

    30

    20

    10

    0

    d

    B(A)

    2933 42

    47 48 46 4338

    52

    ROOF-AM 566

    63 125 250 500 1k 2k 4k 8k TotalHz

  • 7/29/2019 Fan details

    4/5

    Model A B kg*

    GS-R0 50-56 690 150 9GS-R0 63-71 805 150 10

    GS-R0 80 990 150 13

    GS-R0 90-100 1160 150 15Dimensioni in mm/Dimensions in mm(*) Indicativo/Indicative

    1 - Cappello/Cover2 - Staffe/Brackets3 - Motore/Motor4 - Rete/Grid5 - Convogliatore/Ring casing6 - Base/Base frame7 - Girante/Impeller8 - Rete (accessorio) obbligatorio per lutilizzo

    a bocca liberaGrid (accessory) mandatory for free air

    1

    2

    3

    4

    5

    6

    7

    8

    ROOF-AM Dimensioni

    Dimensions

    Model A BxB CxC D E F kg*

    50 510 760 710 1000 450 10 3856 570 760 710 1000 450 10 42

    63 640 930 870 1200 500 10 5871 710 930 870 1200 500 10 6780 815 1150 1050 1600 650 12 8590 915 1300 1200 1600 650 12 110100 1015 1300 1200 1600 700 12 140

    Dimensioni in mm/Dimensions in mm(*) Indicativo/Indicative

    69

    BxB

    CxC

    n4F

    A

    D

    E

    SERRANDE A GRAVIT (GS-RO)Le alette della serranda di gravit si aprono con il movimentodellaria a ventilatore acceso e si richiudono per gravit al suospegnimento evitando dispersioni di calore.

    B

    A

    GRAVITY SHUTTERS (GS-RO)Blades of the shutter are opened by the airflow when the fan isoperating and they shut by gravity when the fan stops, thus avoidingheat waste.

  • 7/29/2019 Fan details

    5/5

    acce

    ssori

    acce

    ssori

    es

    ROOF-AM Accessori

    Accessories

    APPLICAZIONILe basi d'appoggio ondulate SB (converse) realizzate in robustavetroresina, sono adatte per l'installazione dei nostri torrinisu coperture costruite in lastre ondulate, evitando dannosiristagni d'acqua attorno al ventilatore e costose opere murarieo di carpenteria.

    V E R S I O N ISBl e SBc: utilizzabile con torrini aventi basamento 930x930 mm(Modelli 63 e 71).

    SBr: riduzione da accoppiare con basi SBI e SBc per installazionitorrini aventi basamento 760x760 mm (Modelli 50 e 56).

    Le versioni SB possono essere accoppiate a lastre ondulate conpendenza falda tipo:- SBl/1 10x146 : internazionale ( passo 146 mm altezza 48 mm.)- SBl/2 10x177 : Euro ( passo 177 mm altezza 51 mm mod.)- SBc : Euro ( passo 177 mm altezza 51 mm e raggio di curvaturalastra pari a 3 metri

    INSTALLAZIONESovrapporre la conversa alla lastra a valle e sottoposizionarla amonte. Sovrapporsi di almeno un'onda e un quarto con le lastrelaterali attigue.

    Verificare di non avere sovraccaricato eccessivamente la conversa.

    70

    60

    60

    1250

    60

    60

    1300

    177

    51

    146

    48

    SBI/1 10x146 SBI/2 10x177177

    51

    SBc

    Basi dappoggio ondulate per torrini/Support bases for roof fans

    SBl920x920

    Mod. 63/71

    1

    70

    R3000

    2400

    SBc

    APPLICATIONSThe support basesSB (valleys), manufactured in sturdy glass-resin,are suitable for the installation of our roof fans on overlays builtin corrugated slabs, avoiding detrimental stagnations of waternearby the fan and costly masonry or carpentry works .

    VERSIONSSBl eSBc :to be used with roof fans having bases 930x930 mm(Models 63 and 71)

    SBr : Adaptor to be coupled with soaker bases SBl and SBc forinstallation of roof fans having base 760x760 ( Models 50 , 56 ).

    Both versions SBl and SBc are suitable to be coupled to corrugatedslabs with pitch slope type :- SBl/1 10x146 : International type (pitch 146 mm height 48 mm)- SBl/2 10x177: Euro type (pitch 177 mm height 51mm)- SBc : Euro type (pitch 177 mm height 51 mm) and radius ofcurvature of the sheet

    of 3 meters.

    INSTALLATIONOverlap the valley to the slab downstream and under-place itupstream. Overlap not less than one and fourth wave with thelateral adjacent slabs.Verify not to have excessively overloaded the valley

    SBI - SBcper/for mod. 63-71 SBI - SBccon/with SBr per/for mod. 50-56

    SBcSBI

    920x920Mod. 63/71

    250

    1820

    10%

    SBr740

    ESTERNO/EXTERNAL

    635ESTERNO/EXTERNAL

    480

    945

    ESTERNO/EXTERNAL

    INTERNO/INTERNAL

    46180

    425

    SBr

    SB