Torrino assiale ad anello - motore UNEL-MECRing axial roof fans - IEC motor
APPLICATIONSROOF-AM line is designed to extract large volumes of air in roofinstallations, without long ducts. For instance: ventilation ofindustrial buildings (factories, warehouses etc.), stock farms andelectrical equipments etc.
RANGEThis line consists of 7 sizes with impeller from 500 up to 1000 mm.
ADVANTAGESThis line is characterized by the wide round shaped nozzles in bothinlet and outlet, warranty of reduced noise level and high efficiency.Besides these fans allow the effective operation either in exhaustor supply duty. Electric motor is easily accessible for wiring and
maintenance operations, manufactured according to internationalstandards assuring reliability and the long-term economic recoveryof the unit simply repairing or replacing the motor itself.
CONSTRUCTIONRing casing with double wide round shaped nozzle, and baseresistant to the atmospheric agents.Upper cover in techno-polymer resistant to the atmosphericagents.Protection grid on outlet side in steel rod, manufactured accordingto UNI 9219.Inside protection grid (in lack of shutter or ducts).Impeller with high efficiency airfoil blades. Hub in die-castaluminum alloy. Balancing according to UNI ISO 1940. Variablepitch angle in still position.Asynchronous electric motor, protection IP 55, Class F insulated,service S1, construction according to IEC/EEC (UNEL-MEC)standard.Arrangement 4 (impeller directly coupled to motor shaft).
TECHNICAL SPECIFICATIONSROOF-AM standard
Conveyed air: clean, not abrasive.Temperature of conveyed air: -20C / +50C.Voltage: three phase version (T) 400V-3Ph.
Single phase version (M) 230V-1Ph.Frequency: 50Hz.Working as exhaust fan.
ACCESSORIESInlet gravity shutter, only for exhaust fans (GS-RO).Service switch.Outer terminal box (OTB).Support base for corrugate roof covering (SB).Silencer (SIL-RO).Counter base (CB).Inlet grid (PG) mandatory for use in free air.Service switch (SW).
ON REQUESTIntake versions.Versions with air flow 100% reversible (ROOF-REV).Versions with three phase double polarity electric motor.Versions with casing and base in stainless steel or aluminum.Explosion proof versions (Roof-AM Atex)Versions with metal sheet cover.
APPLICAZIONII torrini serie ROOF-AM sono destinati ad impieghi in cui necessitanograndi portate daria, in applicazioni a tetto, senza lunghecanalizzazioni. Ad esempio: ventilazione di edifici industriali(stabilimenti, magazzini), allevamenti, sala macchine, ecc.
GAMMALa serie costituita da 7 grandezze con diametro girante da 500a1000 mm.
PECULIARITLa serie ROOF-AM caratterizzata dalla presenza di imbocchi adampio raggio di curvatura, sia all'ingresso che all'uscita dell'aria, iquali garantiscono massima silenziosit ed elevati rendimenti aeraulici,
inoltre essi consentono l'efficace utilizzo del torrino come estrattoreo come immissore. Il motore facilmente raggiungibile sia pereffettuare il primo collegamento elettrico sia per esigenze dimanutenzione. Il motore costruito seguendo standard internazionaligarantendo cos affidabilit ed a lungo termine un economicorecupero del ventilatore semplicemente riparando o sostituendo ilmotore stesso.
COSTRUZIONEConvogliatore ad anello con doppio bordo ad ampio raggio dicurvatura e base dancoraggio in lamiera dacciaio, protetta controgli agenti atmosferici.Cappello in tecnopolimero resistente agli agenti atmosferici.Rete antivolatile ed antinfortunistica esterna, realizzata a normeUNI EN 294 in filo dacciaio e protetta contro gli agenti atmosferici.Rete di protezione interna (in assenza di serranda o canalizzazione)Girante ad alto rendimento con pale a profilo alare, ad angolodi calettamento variabile da fermo. Mozzo in fusione d'alluminio.Equilibratura secondo norme UNI ISO 1940.Motore elettrico asincrono a corrente alternata, protezione IP55, isolamento Cl F, servizio S1, costruzioneconforme alle specifiche norme IEC/EEC (UNEL-MEC).Esecuzione 4 (accoppiamento diretto con girante a sbalzo).
SPECIFICHE TECNICHEROOF-AM standard
Aria convogliata: pulita o leggermente polverosa, non abrasiva.Temperatura aria convogliata: -20C / +50CTensione dalimentazione: versione trifase (T) 400V-3Ph
versione monofase (M) 230V-1PhFrequenza: 50Hz.Funzionamento in estrazione.
ACCESSORISerranda a gravit, solo in estrazione (GS-RO).Interruttore di servizio.Morsettiera esterna (OTB).Basi d'appoggio su coperture ondulate (SB).Silenziatore (SIL-RO).Controbase a murare (CB).Rete lato girante (PG) obbligatoria nellutilizzo a bocca libera.Interruttore di servizio (SW).
A RICHIESTAVersioni per funzionamento in immissione.Versioni con flusso dellaria effettivamente reversibile (ROOF-REV) .Versioni con motore elettrico a doppia polarit.Versioni con convogliatore e base in acciaio inossidabile o alluminio.Versioni ATEX (Roof-AM Atex).Versioni con cappello in metallo.
66
ROOF-AMROOF-AM
-
7/29/2019 Fan details
2/5
ROOF-AM Prestazioni
Performances
Modello Portata - Flow rate Pm In max Mot. Lp
Model (m3/h) (kW) (A) (H) dB(A)
504 T 7.200 0,55 1,6 80 60564 T 10.500 0,75 2 80 61634 T 14.000 1,1 2,8 90S 66
4 poli/poles(1500 rpm) - trifase/three-phases(3Ph-400V 50Hz)
1 mm H2O= 9,8 Pa
Modello Portata - Flow rate Pm In max Mot. Lp
Model (m3/h) (kW) (A) (H) dB(A)
808B T 16.500 0,75 2,3 100 57908A T 18.800 0,75 2,3 100 571008A T 22.500 1,1 3,4 100L 60
8 poli/poles(750 rpm) - trifase/three-phases(3Ph-400V 50Hz)
Modello Portata - Flow rate Pm In max Mot. Lp
Model (m3/h) (kW) (A) (H) dB(A)
506 T 5.100 0,18 0,7 71 49566 T 6.900 0,25 1 71 52
636A T 9.500 0,37 1,3 80 57
636B T 10.500 0,55 1,8 80 59716A T 12.500 0,75 2,2 90S 59716B T 16.000 1,1 3 90 61806 T 20.000 1,5 4 100 62
906 T 25.000 1,5 4 100 631006 T 30.000 2,2 5 112 66
6 poli/poles(1000 rpm) - trifase/three-phases(3Ph-400V 50Hz)
8.000
16
7.0006.0005.000
2
0
6
4
12
8
10
14
636A
17.000 19.00012.00010.0009.000 15.000
716A
22.000 24.000 26.000
806
29.000 31.000
906 1006
Q(m3/h)
636B
716B
67
6
3
1
4
2
5
6.000 8.000 10.000 12.000
0
13.000 14.000 21.000 23.00016.000 19.000
8
9
908A1008A
Ps(mm
H2O)
808B
26.000
Q(m3/h)
504
0
10
4.0003.000 5.000 6.000 12.0007.000 8.000 9.000 14.000 16.000
2
4
6
8
12
14
16
564
634
Q(m3/h)
Ps(mm
H2O)
Ps(mm
H2O)
566
506
-
7/29/2019 Fan details
3/5
ROOF-AM Rumorosit
Noise level
Livello Pressione Sonora Lp dB(A) 6m
Sound Pressure Level Lp dB(A) 6m
80
70
60
50
40
30
20
10
063 125 250 500 1k 2k 4k 8k Total
Hz
dB(A)
36
5155
60 61 59 5651
66
ROOF-AM 1006
80
70
60
50
40
30
2010
0
dB(A)
23
4347 47
53 5549 47
59
ROOF-AM 716 A
63 125 250 500 1k 2k 4k 8k TotalHz
80
70
60
50
40
30
20
10
0
dB(A)
27
46
56 5454
5452 44
61
ROOF-AM 564
63 125 250 500 1k 2k 4k 8k TotalHz
80
70
60
5040
30
20
10
0
dB(A)
31
46 5657 60
6357
49
66
ROOF-AM 634
63 125 250 500 1k 2k 4k 8k TotalHz
80
70
60
50
40
30
20
10
0
d
B(A)
22
37
47 4551 54 48
40
57
ROOF-AM 636 A
63 125 250 500 1k 2k 4k 8k TotalHz
80
70
60
50
40
30
20
10
0
dB(A)
31
4549
56 55 53 5045
60
ROOF-AM 1008 A
63 125 250 500 1k 2k 4k 8k Total
Hz
80
70
60
50
40
30
20
10
0
dB(A)
27
4246
51 52 50 4742
57
ROOF-AM 908 A
63 125 250 500 1k 2k 4k 8k Total
Hz
80
70
60
50
40
30
20
10
0
dB(A)
32
4751
56 57 5552
47
62
ROOF-AM 806
63 125 250 500 1k 2k 4k 8k TotalHz
80
70
60
50
40
30
20
10
0
dB(A)
33
4852
57 58 56 5348
63
ROOF-AM 906
63 125 250 500 1k 2k 4k 8k TotalHz
80
70
60
50
40
30
20
10
0
dB(A) 46 48 53 53 53 53 52 52
60
ROOF-AM 504
63 125 250 500 1k 2k 4k 8k TotalHz
Attenzione: il livello di pressione sonora riferito ad una misurazione onnidirezionale in campo libero a 6 m dal ventilatore con aspirazionecanalizzata e mandata libera.Attention: sound pressure level is measured in free field at 6 m from the fan, in any direction, with ducted inlet and free outlet.
80
70
60
50
40
30
2010
0
dB(A)
23
4347 47
53 5549 47
59
ROOF-AM 636 B
63 125 250 500 1k 2k 4k 8k TotalHz
80
70
60
50
40
30
20
10
0
dB(A)
3337
4751 52 50 47 42
57
ROOF-AM 808 B
63 125 250 500 1k 2k 4k 8k Total
Hz
80
70
60
50
40
30
2010
0
dB(A)
31
49 5156 57 55
5247
61
ROOF-AM 716 B
63 125 250 500 1k 2k 4k 8k TotalHz
68
80
70
60
50
40
30
20
10
0
d
B(A)
2630
39
44 45 43
40 35
49
ROOF-AM 506
63 125 250 500 1k 2k 4k 8k TotalHz
80
70
60
50
40
30
20
10
0
d
B(A)
2933 42
47 48 46 4338
52
ROOF-AM 566
63 125 250 500 1k 2k 4k 8k TotalHz
-
7/29/2019 Fan details
4/5
Model A B kg*
GS-R0 50-56 690 150 9GS-R0 63-71 805 150 10
GS-R0 80 990 150 13
GS-R0 90-100 1160 150 15Dimensioni in mm/Dimensions in mm(*) Indicativo/Indicative
1 - Cappello/Cover2 - Staffe/Brackets3 - Motore/Motor4 - Rete/Grid5 - Convogliatore/Ring casing6 - Base/Base frame7 - Girante/Impeller8 - Rete (accessorio) obbligatorio per lutilizzo
a bocca liberaGrid (accessory) mandatory for free air
1
2
3
4
5
6
7
8
ROOF-AM Dimensioni
Dimensions
Model A BxB CxC D E F kg*
50 510 760 710 1000 450 10 3856 570 760 710 1000 450 10 42
63 640 930 870 1200 500 10 5871 710 930 870 1200 500 10 6780 815 1150 1050 1600 650 12 8590 915 1300 1200 1600 650 12 110100 1015 1300 1200 1600 700 12 140
Dimensioni in mm/Dimensions in mm(*) Indicativo/Indicative
69
BxB
CxC
n4F
A
D
E
SERRANDE A GRAVIT (GS-RO)Le alette della serranda di gravit si aprono con il movimentodellaria a ventilatore acceso e si richiudono per gravit al suospegnimento evitando dispersioni di calore.
B
A
GRAVITY SHUTTERS (GS-RO)Blades of the shutter are opened by the airflow when the fan isoperating and they shut by gravity when the fan stops, thus avoidingheat waste.
-
7/29/2019 Fan details
5/5
acce
ssori
acce
ssori
es
ROOF-AM Accessori
Accessories
APPLICAZIONILe basi d'appoggio ondulate SB (converse) realizzate in robustavetroresina, sono adatte per l'installazione dei nostri torrinisu coperture costruite in lastre ondulate, evitando dannosiristagni d'acqua attorno al ventilatore e costose opere murarieo di carpenteria.
V E R S I O N ISBl e SBc: utilizzabile con torrini aventi basamento 930x930 mm(Modelli 63 e 71).
SBr: riduzione da accoppiare con basi SBI e SBc per installazionitorrini aventi basamento 760x760 mm (Modelli 50 e 56).
Le versioni SB possono essere accoppiate a lastre ondulate conpendenza falda tipo:- SBl/1 10x146 : internazionale ( passo 146 mm altezza 48 mm.)- SBl/2 10x177 : Euro ( passo 177 mm altezza 51 mm mod.)- SBc : Euro ( passo 177 mm altezza 51 mm e raggio di curvaturalastra pari a 3 metri
INSTALLAZIONESovrapporre la conversa alla lastra a valle e sottoposizionarla amonte. Sovrapporsi di almeno un'onda e un quarto con le lastrelaterali attigue.
Verificare di non avere sovraccaricato eccessivamente la conversa.
70
60
60
1250
60
60
1300
177
51
146
48
SBI/1 10x146 SBI/2 10x177177
51
SBc
Basi dappoggio ondulate per torrini/Support bases for roof fans
SBl920x920
Mod. 63/71
1
70
R3000
2400
SBc
APPLICATIONSThe support basesSB (valleys), manufactured in sturdy glass-resin,are suitable for the installation of our roof fans on overlays builtin corrugated slabs, avoiding detrimental stagnations of waternearby the fan and costly masonry or carpentry works .
VERSIONSSBl eSBc :to be used with roof fans having bases 930x930 mm(Models 63 and 71)
SBr : Adaptor to be coupled with soaker bases SBl and SBc forinstallation of roof fans having base 760x760 ( Models 50 , 56 ).
Both versions SBl and SBc are suitable to be coupled to corrugatedslabs with pitch slope type :- SBl/1 10x146 : International type (pitch 146 mm height 48 mm)- SBl/2 10x177: Euro type (pitch 177 mm height 51mm)- SBc : Euro type (pitch 177 mm height 51 mm) and radius ofcurvature of the sheet
of 3 meters.
INSTALLATIONOverlap the valley to the slab downstream and under-place itupstream. Overlap not less than one and fourth wave with thelateral adjacent slabs.Verify not to have excessively overloaded the valley
SBI - SBcper/for mod. 63-71 SBI - SBccon/with SBr per/for mod. 50-56
SBcSBI
920x920Mod. 63/71
250
1820
10%
SBr740
ESTERNO/EXTERNAL
635ESTERNO/EXTERNAL
480
945
ESTERNO/EXTERNAL
INTERNO/INTERNAL
46180
425
SBr
SB