FAMILY 50 - cei-italy.com rev0 ENG.pdf · 50 50 mm 40 mm kg 4.3 27 a 14.5 a kg 1.170 40 40 mm 40 mm...

21
C.E.I. srl CON INTERRUTTORE INTERNO WITH INTERNAL SWITCH PER INTERRUTTORE ESTERNO FOR EXTERNAL SWITCH TRAZIONE PULL SPINTA PUSH TRAZIONE PULL SPINTA PUSH TRAZIONE PULL SPINTA PUSH MODELLI MODELS “SPECIAL” CON INTERRUTTORE INTERNO WITH INTERNAL SWITCH TRAZIONE PULL PER INTERRUTTORE ESTERNO FOR EXTERNAL SWITCH TRAZIONE PULL SPINTA PUSH 60 GRUPPO FAMILY 46 GRUPPO FAMILY 50 GRUPPO FAMILY 40 GRUPPO FAMILY COSTRUZIONI ELETTROMAGNETICHE INDUSTRIALI CORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAX. 0039 0119591357 e-mail: [email protected] www.cei-italy.it STAFFA BRACKET A STAFFA BRACKET B STAFFA BRACKET A STAFFA BRACKET B STAFFA BRACKET A STAFFA BRACKET B STAFFA BRACKET C INTERMITTENTE (D) INTERMITTENT (D) TRAZIONE PULL SPINTA PUSH STAFFA BRACKET A STAFFA BRACKET A STAFFA BRACKET C STAFFA BRACKET A

Transcript of FAMILY 50 - cei-italy.com rev0 ENG.pdf · 50 50 mm 40 mm kg 4.3 27 a 14.5 a kg 1.170 40 40 mm 40 mm...

Page 1: FAMILY 50 - cei-italy.com rev0 ENG.pdf · 50 50 mm 40 mm kg 4.3 27 a 14.5 a kg 1.170 40 40 mm 40 mm kg 1.7 25 a 11 a kg 0.740 modello d - con una sola bobina per servizio intermittente

C.E.I. srl

CON INTERRUTTORE INTERNO WITH INTERNAL SWITCHPER INTERRUTTORE ESTERNO FOR EXTERNAL SWITCH

TRAZIONE PULLSPINTA PUSH

TRAZIONE PULLSPINTA PUSH

TRAZIONE PULLSPINTA PUSH

MODELLI MODELS“SPECIAL”

CON INTERRUTTORE INTERNOWITH INTERNAL SWITCH

TRAZIONEPULL

PER INTERRUTTORE ESTERNOFOR EXTERNAL SWITCH

TRAZIONE PULLSPINTA PUSH

60GRUPPOFAMILY 46GRUPPO

FAMILY

50GRUPPOFAMILY

40GRUPPOFAMILY

C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

e-mail: [email protected] www.cei-italy.it

STAFFA BRACKET A

STAFFA BRACKET B

STAFFA BRACKET A

STAFFA BRACKET B

STAFFA BRACKET A

STAFFA BRACKET B

STAFFA BRACKET C

INTERMITTENTE (D)INTERMITTENT (D)

TRAZIONE PULLSPINTA PUSH

STAFFA BRACKET A

STAFFA BRACKET A

STAFFA BRACKET C

STAFFA BRACKET A

Page 2: FAMILY 50 - cei-italy.com rev0 ENG.pdf · 50 50 mm 40 mm kg 4.3 27 a 14.5 a kg 1.170 40 40 mm 40 mm kg 1.7 25 a 11 a kg 0.740 modello d - con una sola bobina per servizio intermittente

C.E.I. srlC.E.I. srl

SPECIFICHE ELETTROMAGNETICHE ELECTROMAGNETIC SPECIFICATIONS

CODICE DIAMETRO CORSA FORZA ALLA BOBINA DI POTENZA BOBINA DI TENUTA PESO GRUPPO DIAMETER STROKE PARTENZA PULL COIL HOLD COIL WEIGHT FAMILY FORCE CODE Ø MAX AT START 12 V.C.C. 24 V.C.C 12 V.C.C. 24 V.C.C

60 60 mm 50 mm kg 8.4 47 A 24.5 A 0.65 A 0.30 A kg 1.950 46 46 mm 26 mm kg 7 40 A 23.5 A 0.60 A 0.30 A kg 0.810

50 50 mm 40 mm kg 4.3 41 A 23 A 0.50 A 0.28 A kg 1.180

40 40 mm 40 mm kg 1.7 31 A 15.2 A 0.53 A 0.29 A kg 0.760

MODELLO E - CON DOPPIA BOBINA PER SERVIZIO CONTINUATIVOMODEL E - DUAL COIL SOLENOID FOR CONTINUOUS DUTY

CODICE DIAMETRO CORSA FORZA ALLA ASSORBIMENTO BOBINA PESO GRUPPO DIAMETER STROKE PARTENZA COIL INPUT WEIGHT FAMILY FORCE CODE Ø MAX AT START 12 V.C.C. 24 V.C.C

60 60 mm 50 mm kg 8.4 37 A 20 A kg 1.830 46 46 mm 26 mm kg 7 27 A 13 A kg 0.740

50 50 mm 40 mm kg 4.3 27 A 14.5 A kg 1.170

40 40 mm 40 mm kg 1.7 25 A 11 A kg 0.740

MODELLO D - CON UNA SOLA BOBINA PER SERVIZIO INTERMITTENTEMODEL D - SINGLE COIL SOLENOID FOR INTERMITTENT DUTY

DIAGRAMMA DELLE FORZE E CORSE DIAGRAM OF FORCES AND STROKES

010 20 30 40 50

5

10

15

20

CORSA (mm) STROKE (mm) 1 kg = 9.81 Newtons

FORZA (kg) FORCE (kg)GRUPPOFAMILY

CORSA MASSIMA 50mmMAXIMUM STROKE 50mm60 kg 8.4 (N82)

GRUPPOFAMILY

CORSA MASSIMA 26mmMAXIMUM STROKE 26mm46 kg 7.0 (N68)

GRUPPOFAMILY

CORSA MASSIMA 40mmMAXIMUM STROKE 40mm50 kg 4.3 (N42)

GRUPPOFAMILY

CORSA MASSIMA 40mmMAXIMUM STROKE 40mm40 kg 1.7 (N16)

C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

e-mail: [email protected] www.cei-italy.it

Page 3: FAMILY 50 - cei-italy.com rev0 ENG.pdf · 50 50 mm 40 mm kg 4.3 27 a 14.5 a kg 1.170 40 40 mm 40 mm kg 1.7 25 a 11 a kg 0.740 modello d - con una sola bobina per servizio intermittente

FAMILY E - ES 40

A C

B VERSIONES

C.E.I. srl

Rated voltage 12 V DC 24 V DC Pull current 31 A 15.2 A Hold current 0.53 A 0.29 A Duty service Continuous (100%) Stroke 40 mm Force at starting 1.7 Kg Windings insulation class H (180° C) Ambient temperature -40° C ÷ 120° C Weight 0.76 Kg

SPECIFICATIONS

OPERATIONThe solenoid has two windings:An intermittent-service pulling winding involved in the initial phase for approximately 150 ms, with the function of moving the plunger.A continuous-service holding winding, with the function of maintaining the plunger in position.For a proper operation of the solenoid, it is indispensable for the plunger to reach end of travel and to obtain the perfect adherence to the bottom.

00.4

0.6

0.8

1.0

1.2

25 50 75 100 125 °C

FORCE VARIATION COEFFICIENT ACCORDINGWITH AMBIENT TEMPERATURE

AMBIENT TEMPERATURE

DUAL COIL SOLENOID FOR PULL ACTION OR PULL-PUSH ACTION

BRACKET A BRACKET

B BRACKET C

Ø40

Ø40

104

104

3222.5

73÷33

73÷33

M6x20

M6x20

Ø7

Ø7

25

36

52

52

65

3

3

Ø40

104

51

73÷33M6x20

Ø7

2.5

Ø40M635

50188

M6x20

PUSH ACTION, AND-OF-STROKEBRACKETS A, B,C

0 10 20 30 40

5

10

15DIAGRAM OF FORCES AND STROKESForce (Kg)

Stroke (mm)

Kg 1.7 (N16)

1 Kg = 9.81 Newtons

Versions Voltages Circuits Brackets Optional Springs Electrical connections E4 pull action 1 = 12 V DC 1 = Series 1 A M1 Standard Faston ES4 pull-push action 2 = 24 V DC 2 = Series 2 B M2 F = Cables 3 = Series 3 C M3 V = Faston - screws

AVAILABLE OPTIONSThe desired model has to be defined choosing one option in every column, building in this way the solenoid code.

C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

e-mail: [email protected] www.cei-italy.it

Page 4: FAMILY 50 - cei-italy.com rev0 ENG.pdf · 50 50 mm 40 mm kg 4.3 27 a 14.5 a kg 1.170 40 40 mm 40 mm kg 1.7 25 a 11 a kg 0.740 modello d - con una sola bobina per servizio intermittente

FAMILY E - ES 40

C.E.I. srl

DUAL COIL SOLENOID FOR PULL ACTION OR PULL-PUSH ACTION

ELECTRIC CIRCUITS FOR DIESEL ENGINES

OPTIONAL SPRINGS

SERIES 1 WITH INTERNAL SWITCH

DIRECT ELECTRIC CIRCUITThe solenoid connection is not conditioned by the polarity (+ and -)In the version with cables these are blue.

ELECTRICALCONNECTIONS

BY FASTON FASTON

CONNECTIONS

BY CABLES F

BLUE

L = 200 mm

BY SCREWS V

SCREWS

PU

LL C

OIL

HO

LD C

OIL

BATTERY

OFF

ON

START

RELE’

SERIES 3 WITHOUT INTERNAL SWITCH

The connection of the solenoid is the same as for the Series 2. The pull coil Pand the hold coil T are respectively marked PULL and HOLD.The negative common in the version with faston is at ground.• Designed for coupling with starter motor.• Designed for external switch (Code CEI IE04 - timed static electronic switch ideal for dusty or saline environments and in applications with repeated accelerations).

ELECTRICALCONNECTIONS

BY FASTONSMALL ANDLARGE

FASTONCONNECTIONS

BY CABLES F

L = 200 mm

BY SCREWS V

SCREWS

PULL

CO

IL

HO

LD C

OIL

BATTERY

OFF

ON

START

HP

HP

SERIES 2 WITH INTERNAL SWITCH

ELECTRIC CIRCUIT COMBINED WITH STARTER MOTORThe solenoid connection feeding the pull coil P and the hold coil T is marked with the indication PULL (red cable) and HOLD (blue cable). The body is connected to ground. The pull coil P is fed in parallel with the starter motor: the red cable connected to the positive of the starter motor and the blue cable connected to the positive of the key switch. The auxiliary switch K ensures disconnection of the coil P and prevents the possible damaging return of parasitic currents.

ELECTRICALCONNECTIONS HOLD

BLUEL = 200 mm

PULLRED

HOLD

H = HOLDP = PULL

H = HOLDP = PULL

BLUEPULLRED

PULL

CO

IL

HO

LD C

OIL

BATTERY STARTER MOTOR

OFFON

START

STARTER RELE’

STARTER MOTOR

STARTER RELE’

K

T P

INTERNAL SPRING 4M1WIRE DIAMETER SPRING 1

Kg 0.4 at 25 mm Kg 1.5

INTERNAL SPRING 4M2WIRE DIAMETER SPRING 1.2

Kg 0.9 at 25 mm Kg 3.0

INTERNAL SPRING 4M3WIRE DIAMETER SPRING 1.3

Kg 1.1 at 25 mm Kg 4.0

BY CABLES F

ACCESSORIES WITH M6 THREAD

PW6THREADED DOWELM6 - 1/4 UNF L = 38 mm

P6 THREADED DOWELL = 45 mm

CLE6UNI CLEVIS

SM6AXIAL ARTICULATEDJOINT

IM690° ARTICULATEDJOINT

SBJSPRING SWIVEL

30°

AM6AXIAL ARTICULATED JOINT

Ø 6

Ø 6

30°

T P

C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

e-mail: [email protected] www.cei-italy.it

COMMONBLACK

Page 5: FAMILY 50 - cei-italy.com rev0 ENG.pdf · 50 50 mm 40 mm kg 4.3 27 a 14.5 a kg 1.170 40 40 mm 40 mm kg 1.7 25 a 11 a kg 0.740 modello d - con una sola bobina per servizio intermittente

FAMILY E - ES 50

C.E.I. srl

Rated voltage 12 V DC 24 V DC Pull current 41 A 23 A Hold current 0.50 A 0.28 A Duty service Continuous (100%) Stroke 40 mm Force at starting 4.3 Kg Windings insulation class H (180° C) Ambient temperature -40° C ÷ 120° C Weight 1.18 Kg

SPECIFICATIONS

OPERATIONThe solenoid has two windings:An intermittent-service pulling winding involved in the initial phase for approximately 150 ms, with the function of moving the plunger.A continuous-service holding winding, with the function of maintaining the plunger in position.For a proper operation of the solenoid, it is indispensable for the plunger to reach end of travel and to obtain the perfect adherence to the bottom.

00.4

0.6

0.8

1.0

1.2

25 50 75 100 125 °C

FORCE VARIATION COEFFICIENT ACCORDINGWITH AMBIENT TEMPERATURE

AMBIENT TEMPERATURE

DUAL COIL SOLENOID FOR PULL ACTION OR PULL-PUSH ACTION

0 10 20 30 40

5

10

15DIAGRAM OF FORCES AND STROKESForce (Kg)

Stroke (mm)

Kg 4.3 (N42)

1 Kg = 9.81 Newtons

0 10 20 30 40

5

10

15DIAGRAMMA FORZA-CORSAForza (Kg)

Corsa (mm)

Kg 4.3 (N42)

1 Kg = 9.81 Newtons

Versions Voltages Circuits Brackets Optional Springs Electrical connections E5 pull action 1 = 12 V DC 1 = Series 1 A M1 Standard Faston ES5 pull-push action 2 = 24 V DC 2 = Series 2 B M2 F = Cables 3 = Series 3 C (series 3) M3 V = Faston - screws M4 (external)

AVAILABLE OPTIONSThe desired model has to be defined choosing one option in every column, building in this way the solenoid code.

C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

e-mail: [email protected] www.cei-italy.it

BRACKET A BRACKET

B BRACKET C

A

VERSIONES

B

C

Ø50

Ø50 Ø50

Ø 7.3

Ø 7.5

63

30 80 2.5

52

36

75÷35

52 38 28

38

BRACKETS A, B, C

8035

50199

M6

2.5

M6x20

M6x20

102÷6220 75-358021

79,5

M6x20

Ø50 97

56

Ø 9

Page 6: FAMILY 50 - cei-italy.com rev0 ENG.pdf · 50 50 mm 40 mm kg 4.3 27 a 14.5 a kg 1.170 40 40 mm 40 mm kg 1.7 25 a 11 a kg 0.740 modello d - con una sola bobina per servizio intermittente

FAMILY E - ES 50

C.E.I. srl

DUAL COIL SOLENOID FOR PULL ACTION OR PULL-PUSH ACTIONELECTRIC CIRCUITS FOR DIESEL ENGINES

OPTIONAL SPRINGS

SERIES 1 WITH INTERNAL SWITCH

DIRECT ELECTRIC CIRCUITThe solenoid connection is not conditioned by the polarity (+ and -)In the version with cables these are blue.

ELECTRICALCONNECTIONS

BY FASTON FASTON

CONNECTIONS

BY CABLES F

BLUE

L = 200 mm

BY SCREWS V

SCREWS

PULL

CO

IL

HO

LD C

OIL

BATTERY

OFF

ON

START

RELE’

SERIES 3 WITHOUT INTERNAL SWITCH

The connection of the solenoid is the same as for the Series 2. The pull coil Pand the hold coil T are respectively marked PULL and HOLD.The negative common in the version with faston is at ground.• Designed for coupling with starter motor.• Designed for external switch (Code CEI IE04 - timed static electronic switch ideal for dusty or saline environments and in applications with repeated accelerations).

ELECTRICALCONNECTIONS

BY FASTONSMALL ANDLARGE

FASTONCONNECTIONS

BY CABLES F

L = 200 mm

BY SCREWS V

SCREWS

PULL

CO

IL

HO

LD C

OIL

BATTERY

OFF

ON

START

HP

HP

SERIES 2 WITH INTERNAL SWITCH

ELECTRIC CIRCUIT COMBINED WITH STARTER MOTORThe solenoid connection feeding the pull coil P and the hold coil T is marked with the indication PULL (red cable) and HOLD (blue cable). The body is connected to ground. The pull coil P is fed in parallel with the starter motor: the red cable connected to the positive of the starter motor and the blue cable connected to the positive of the key switch. The auxiliary switch K ensures disconnection of the coil P and prevents the possible damaging return of parasitic currents.

ELECTRICALCONNECTIONS HOLD

BLUEL = 200 mm

PULLRED

PULL

H = HOLDP = PULL

H = HOLDP = PULL

RED

HOLDBLUE

PULL

CO

IL

HO

LD C

OIL

BATTERY

OFFON

START

K

T P

INTERNAL SPRING 5M1WIRE DIAMETER SPRING 1

Kg 0.3 Kg 1.5

INTERNAL SPRING 5M2WIRE DIAMETER SPRING 1.25

Kg 0.4 Kg 2.5

INTERNAL SPRING 5M3WIRE DIAMETER SPRING 1.45

Kg 2.6 Kg 6.0

EXTERNAL SPRING 5M4

Kg 4.2 Kg 6.0

STARTER MOTOR

STARTER RELE’

STARTER MOTOR

STARTER RELE’

BY CABLES F

ACCESSORIES WITH M6 THREAD

PW6THREADED DOWELM6 - 1/4 UNF L = 38 mm

P6 THREADED DOWELL = 45 mm

CLE6UNI CLEVIS

SM6AXIAL ARTICULATEDJOINT

IM690° ARTICULATEDJOINT

SBJSPRING SWIVEL

30°

AM6AXIAL ARTICULATED JOINT

Ø 6

Ø 6

30°

T P

C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

e-mail: [email protected] www.cei-italy.it

COMMONBLACK

Page 7: FAMILY 50 - cei-italy.com rev0 ENG.pdf · 50 50 mm 40 mm kg 4.3 27 a 14.5 a kg 1.170 40 40 mm 40 mm kg 1.7 25 a 11 a kg 0.740 modello d - con una sola bobina per servizio intermittente

C.E.I. srl

OPERATIONThe solenoid has two windings:1) An intermittent-service pulling winding involved in the

initial phase for approximately 150 ms, with the function of moving the plunger.

2) A continuous-service holding winding, with the function of maintaining the plunger in position.

For a proper operation of the solenoid, it is indispensable for the plunger to reach end of travel and to obtain the perfect adherence to the bottom.

FAMILY E - ES 46DUAL COIL SOLENOID FOR PULL ACTION OR PULL-PUSH ACTION

Versions Voltages Circuits Brackets Optional Springs Electrical connections

E46 pull action 1 = 12 V DC 1 = Series 1 A M1 Standard Cables ES46 pull-push action 2 = 24 V DC 2 = Series 2 C M2 (only series 3) 3 = Series 3 C2 M3

SPECIFICATIONS

A

VERSIONES

A

C

C2

SERIES 1-2INTERNALSWITCHING

SERIES 3

BRACKET A

SERIES 1-2

Ø46

Ø46

63

97

26

26

2.5

2.5

577

7

26

M6x20

M6x20

SERIES 3

Ø46

26 mm26 mm

FOR PULLACTION

FOR PUSHACTION

153

M6x20

M6x10

51

63

28 97 26

57

51

BRACKET A

SERIES 3EXTERNALSWITCHING

BRACKET C

59 38-64 Ø 7

78 63,5

M6x203

Ø 46

59 38-64

M6x203

Ø 46 95 76

55

Ø 7

Rated voltage 12 V DC 24 V DC Pull current 40 A 23.5 A Hold current 0.60 A 0.30 A Duty service Continuous (100%) Stroke 26 mm Force at starting 7 Kg Windings insulation class H (180° C) Ambient temperature -40° C ÷ 120° C Weight 0.81 Kg

00.4

0.6

0.8

1.0

1.2

25 50 75 100 125 °C

FORCE VARIATION COEFFICIENT ACCORDINGWITH AMBIENT TEMPERATURE

AMBIENT TEMPERATURE

5

10

15DIAGRAM OF FORCES AND STROKESForce (Kg)

0 4 8 12 16 20 24 28Stroke (mm)

Kg 7 (N68)

1 Kg = 9.81 Newtons

AVAILABLE OPTIONSThe desired model has to be defined choosing one option in every column, building in this way the solenoid code.

C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

e-mail: [email protected] www.cei-italy.it

Page 8: FAMILY 50 - cei-italy.com rev0 ENG.pdf · 50 50 mm 40 mm kg 4.3 27 a 14.5 a kg 1.170 40 40 mm 40 mm kg 1.7 25 a 11 a kg 0.740 modello d - con una sola bobina per servizio intermittente

FAMILY E - ES 46

C.E.I. srl

DUAL COIL SOLENOID FOR PULL ACTION OR PULL-PUSH ACTION

ELECTRIC CIRCUITS FOR DIESEL ENGINES

OPTIONAL SPRINGS

SERIES 1 WITH INTERNAL SWITCH

DIRECT ELECTRIC CIRCUITThe solenoid connection is not conditioned by the polarity (+ and --)In the version with cables these are blue.

ELECTRICALCONNECTIONS

BLUE

BLUE

L = 150 mm

PULL

CO

IL

HO

LD C

OIL

BATTERY

OFF

ON

START

RELE’

SERIES 3 WITHOUT INTERNAL SWITCH

The connection of the solenoid is the same as for the Series 2 circuit and is distinguished by PULL and HOLD.In the version with cables, these are respectively red and blue.• Designed for coupling with starter motor.• Designed for external switch (Code CEI IE04 - timed static electronic switch ideal for dusty or saline environments and in applications with repeated accelerations).

ELECTRICALCONNECTIONS

RED - PULL

BLACK - COMMON

BLUE - HOLD

PULL

CO

IL

HO

LD C

OIL

BATTERY

OFF

ON

START

SERIES 2 WITH INTERNAL SWITCH

ELECTRIC CIRCUIT COMBINED WITH STARTER MOTORThe solenoid connection feeding the pull coil P and the hold coil T is marked with the indication PULL (red cable) and HOLD (blue cable). The body is connected to ground. The pull coil P is fed in parallel with the starter motor: the red cable connected to the positive of the starter motor and the blue cable connected to the positive of the key switch. The auxiliary switch K ensures disconnection of the coil P and prevents the possible damaging return of parasitic currents.

ELECTRICALCONNECTIONS

PULL

CO

IL

HO

LD C

OIL

BATTERY

OFFON

START

K

T P

INTERNAL SPRING 5M1WIRE DIAMETER SPRING 1

Kg 0.700 Kg 1.5

INTERNAL SPRING 5M2WIRE DIAMETER SPRING 1.25

Kg 1.100 Kg 2.5

INTERNAL SPRING 5M3WIRE DIAMETER SPRING 1.45

Kg 3.800 Kg 6.0

HOLDBLUE

PULLRED

L = 150 mm

L = 150 mm

STARTER MOTOR

STARTER RELE’

STARTER MOTOR

STARTER RELE’

BY CABLES

BY CABLES

BY CABLES

C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

e-mail: [email protected] www.cei-italy.it

ACCESSORIES WITH M6 THREAD

PW6THREADED DOWELM6 - 1/4 UNF L = 38 mm

P6 THREADED DOWELL = 45 mm

CLE6UNI CLEVIS

SM6AXIAL ARTICULATEDJOINT

IM690° ARTICULATEDJOINT

SBJSPRING SWIVEL

30°

AM6AXIAL ARTICULATED JOINT

Ø 6

Ø 6

30°

Page 9: FAMILY 50 - cei-italy.com rev0 ENG.pdf · 50 50 mm 40 mm kg 4.3 27 a 14.5 a kg 1.170 40 40 mm 40 mm kg 1.7 25 a 11 a kg 0.740 modello d - con una sola bobina per servizio intermittente

FAMILY E - ES 60

A VERSIONES

B

C.E.I. srl

Rated voltage 12 V DC 24 V DC Pull current 47 A 24.5 A Hold current 0.65 A 0.30 A Duty service Continuous (100%) Stroke 50 mm Force at starting 8.4 Kg Windings insulation class H (180° C) Ambient temperature -40° C ÷ 120° C Weight 1.95 Kg

SPECIFICATIONS

OPERATIONThe solenoid has two windings:An intermittent-service pulling winding involved in the initial phase for approximately 150 ms, with the function of moving the plunger.A continuous-service holding winding, with the function of maintaining the plunger in position.For a proper operation of the solenoid, it is indispensable for the plunger to reach end of travel and to obtain the perfect adherence to the bottom.

00.4

0.6

0.8

1.0

1.2

25 50 75 100 125 °C

FORCE VARIATION COEFFICIENT ACCORDINGWITH AMBIENT TEMPERATURE

AMBIENT TEMPERATURE

BRACKETA BRACKET B

DUAL COIL SOLENOID FOR PULL ACTION OR PULL-PUSH ACTION

63

55 38 2.5

33

M8x20

M8x20

30 124 ÷ 74

Ø 7.3

Ø 60 Ø 60

Ø 60

93 5090 ÷ 404Ø 8.5

30

70

44PUSH ACTION, AND-OF-STROKEBRACKETS A, B

50

35

M6

93

219

DIAGRAM OF FORCES AND STROKES

252015105

Force (Kg)

0 10 20 30 40 50Stroke (mm)

Kg 8.4 (N82)

0 10 20 30 40

5

10

15DIAGRAMMA FORZA-CORSAForza (Kg)

Corsa (mm)

Kg 4.3 (N42)

1 Kg = 9.81 Newtons

Versions Voltages Circuits Brackets Optional Springs Electrical connections E6 pull action 1 = 12 V DC 1 = Series 1 A M1 Standard Faston ES6 pull-push action 2 = 24 V DC 2 = Series 2 B M3 (external) F = Cables 3 = Series 3 V = Faston - screws

AVAILABLE OPTIONSThe desired model has to be defined choosing one option in every column, building in this way the solenoid code.

C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

e-mail: [email protected] www.cei-italy.it

Page 10: FAMILY 50 - cei-italy.com rev0 ENG.pdf · 50 50 mm 40 mm kg 4.3 27 a 14.5 a kg 1.170 40 40 mm 40 mm kg 1.7 25 a 11 a kg 0.740 modello d - con una sola bobina per servizio intermittente

FAMILY E - ES 60

C.E.I. srl

DUAL COIL SOLENOID FOR PULL ACTION OR PULL-PUSH ACTIONELECTRIC CIRCUITS FOR DIESEL ENGINES

OPTIONAL SPRINGS

SERIES 1 WITH INTERNAL SWITCH

DIRECT ELECTRIC CIRCUITThe solenoid connection is not conditioned by the polarity (+ and -)In the version with cables these are blue.

ELECTRICALCONNECTIONS

BY FASTON FASTON

CONNECTIONS

BY CABLES F

BLUE

L = 200 mm

BY SCREWS V

SCREWS

PULL

CO

IL

HO

LD C

OIL

BATTERY

OFF

ON

START

RELE’

SERIES 3 WITHOUT INTERNAL SWITCH

The connection of the solenoid is the same as for the Series 2. The pull coil Pand the hold coil T are respectively marked PULL and HOLD.The negative common in the version with faston is at ground.• Designed for coupling with starter motor.• Designed for external switch (Code CEI IE04 - timed static electronic switch ideal for dusty or saline environments and in applications with repeated accelerations).

ELECTRICALCONNECTIONS

BY FASTONSMALL ANDLARGE

FASTONCONNECTIONS

BY CABLES F

L = 200 mm

BY SCREWS V

SCREWS

PULL

CO

IL

HO

LD C

OIL

BATTERY

OFF

ON

START

HP

HP

SERIES 2 WITH INTERNAL SWITCH

ELECTRIC CIRCUIT COMBINED WITH STARTER MOTORThe solenoid connection feeding the pull coil P and the hold coil T is marked with the indication PULL (red cable) and HOLD (blue cable). The body is connected to ground. The pull coil P is fed in parallel with the starter motor: the red cable connected to the positive of the starter motor and the blue cable connected to the positive of the key switch. The auxiliary switch K ensures disconnection of the coil P and prevents the possible damaging return of parasitic currents.

ELECTRICALCONNECTIONS HOLD

BLUEL = 200 mm

PULLRED

PULL

H = HOLDP = PULL

H = HOLDP = PULL

RED

HOLDBLUE

PULL

CO

IL

HO

LD C

OIL

BATTERY

OFFON

START

K

T P

INTERNAL SPRING 6M1

Kg 0.500 Kg 1.5

EXTERNAL SPRING 6M3

Kg 5.000 Kg 12.05

STARTER MOTOR

STARTER RELE’

STARTER MOTOR

STARTER RELE’

BY CABLES F

T P

ACCESSORIES WITH M8 THREAD

30°Ø 8

Ø 8

Ø 6 CLE8UNI CLEVIS

SM8AXIAL ARTICULATEDJOINT

P8THREADED DOWELL = 45 mm

SBJSPRING SWIVEL

IM890° ARTICULATEDJOINT

C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

e-mail: [email protected] www.cei-italy.it

COMMONBLACK

Page 11: FAMILY 50 - cei-italy.com rev0 ENG.pdf · 50 50 mm 40 mm kg 4.3 27 a 14.5 a kg 1.170 40 40 mm 40 mm kg 1.7 25 a 11 a kg 0.740 modello d - con una sola bobina per servizio intermittente

FAMILY D - DS 40

A C

B VERSIONDS

C.E.I. srl

Rated voltage 12 V DC 24 V DC Pull current 25 A 11 A Duty service Intermittent Stroke 40 mm Force at starting 1.7 Kg Windings insulation class H (180° C) Ambient temperature -40° C ÷ 120° C Weight 0.74 Kg

SPECIFICATIONS

BRACKETA BRACKETB BRACKETC

Ø40

95

3222.5

73÷33

M6x20Ø 7

25

5265

3Ø40

95

51

73÷33M6x20

Ø 7

2.5

Ø40

95 73÷33M6x20

Ø 7

36

52

3

Ø40M635

59188

M6x20

PUSH ACTION, AND-OF-STROKEBRACKETS A,B,C

Versions Voltages Circuits Brackets Optional Springs Electrical connections D4 pull action 1 = 12 V DC 1 = Series D A M1 Standard Faston DS4 pull-push action 2 = 24 V DC B M2 F = Cables C

00.4

0.6

0.8

1.0

1.2

25 50 75 100 125 °C

FORCE VARIATION COEFFICIENT ACCORDINGWITH AMBIENT TEMPERATURE

AMBIENT TEMPERATURE

0 10 20 30 40

5

10

15DIAGRAM OF FORCES AND STROKESForce (Kg)

Stroke (mm)

Kg 1.7 (N16)

1 Kg = 9.81 Newtons

SINGLE COIL SOLENOID FOR INTERMITTENT DUTY

OPERATIONThe single coil Elettrostart solenoids are for intermittent duty provinding high FORCE-STROKE pick-up. These solenoids are used to stop diesel engines when energized by actuating the fuel supply lever. The solenoid is de-energized when the engine is running, only in the stop phase it is energized cutting off the fuel flow.Due to its high operating power the energized time must not exceed one minute, while the de-energized time between two energizing phases must be long enough for the solenoid to cool down.

C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

e-mail: [email protected] www.cei-italy.it

AVAILABLE OPTIONSThe desired model has to be defined choosing one option in every column, building in this way the solenoid code.

Page 12: FAMILY 50 - cei-italy.com rev0 ENG.pdf · 50 50 mm 40 mm kg 4.3 27 a 14.5 a kg 1.170 40 40 mm 40 mm kg 1.7 25 a 11 a kg 0.740 modello d - con una sola bobina per servizio intermittente

FAMILY D - DS 40

C.E.I. srl

SINGLE COIL SOLENOID FOR INTERMITTENT DUTY

ELECTRIC CIRCUITS FOR DIESEL ENGINES

ENGINE WITH INJECTION PUMP NORMALLY OPENENGINE SHUTDOWN BY SOLENOID ENERGIZINGINTERMITTENT DUTY

SERIES D INTERMITTENT

ELECTRIC CIRCUIT FOR INTERMITTENT DUTYThe solenoid connection is not conditioned by the polarity(+ and -).

ELECTRICALCONNECTIONS

FOR STOP

BY FASTON FASTON

CONNECTIONS

BY CABLES FRED CABLES

OPTIONAL SPRINGS

INTERNAL SPRING 4M1 WIRE DIAMETER SPRING 1

Kg 0.4 at 25mm Kg 1.5

INTERNAL SPRING 4M2 WIRE DIAMETER SPRING 1.2

Kg 0.9 at 25mm Kg 3.0

EXAMPLE OF APPLICATION

STOP

SHUTDOWN LEVER TRAVEL

RUNNINGPOSITION

END-OF-STROKE

L = 200 mm

30°

Ø 6

Ø 6

30°

ACCESSORIES WITH M6 THREAD

PW6THREADED DOWELM6 - 1/4 UNF L = 38 mm

P6 THREADED DOWELL = 45 mm

CLE6UNI CLEVIS

SM6AXIAL ARTICULATEDJOINT

IM690° ARTICULATEDJOINT

AM6AXIAL ARTICULATED JOINT

C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

e-mail: [email protected] www.cei-italy.it

Page 13: FAMILY 50 - cei-italy.com rev0 ENG.pdf · 50 50 mm 40 mm kg 4.3 27 a 14.5 a kg 1.170 40 40 mm 40 mm kg 1.7 25 a 11 a kg 0.740 modello d - con una sola bobina per servizio intermittente

A

B

VERSIONDS

FAMILY D - DS 50

C.E.I. srl

Rated voltage 12 V DC 24 V DC Pull current 27 A 14.5 A Duty service Intermittent Stroke 40 mm Force at starting 4.3 Kg Windings insulation class H (180° C) Ambient temperature -40° C ÷ 120° C Weight 1.17 Kg

SPECIFICATIONS

00.4

0.6

0.8

1.0

1.2

25 50 75 100 125 °C

FORCE VARIATION COEFFICIENT ACCORDINGWITH AMBIENT TEMPERATURE

AMBIENT TEMPERATURE

0 10 20 30 40

5

10

15DIAGRAM OF FORCES AND STROKESForce (Kg)

Stroke (mm)

Kg 4.3 (N42)

1 Kg = 9.81 Newtons

Versions Voltages Circuits Brackets Optional Springs Electrical connections D5 pull action 1 = 12 V DC 1 = Series D A M1 Standard Faston DS5 pull-push action 2 = 24 V DC B M2 F = Cables

BRACKETA BRACKETB

SINGLE COIL SOLENOID FOR INTERMITTENT DUTY

Ø50

Ø50

Ø50

Ø 7.3

Ø 7.5

63

21 80

52

36

75÷35

43 38 28

38BRACKETS A, B

8035

59199

M6

2.5

2.5

M6x20

M6x20

102÷6220

OPERATIONThe single coil Elettrostart solenoids are for intermittent duty provinding high FORCE-STROKE pick-up. These solenoids are used to stop diesel engines when energized by actuating the fuel supply lever. The solenoid is de-energized when the engine is running, only in the stop phase it is energized cutting off the fuel flow.Due to its high operating power the energized time must not exceed one minute, while the de-energized time between two energizing phases must be long enough for the solenoid to cool down.

RUNNINGPOSITION

C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

e-mail: [email protected] www.cei-italy.it

AVAILABLE OPTIONSThe desired model has to be defined choosing one option in every column, building in this way the solenoid code.

Page 14: FAMILY 50 - cei-italy.com rev0 ENG.pdf · 50 50 mm 40 mm kg 4.3 27 a 14.5 a kg 1.170 40 40 mm 40 mm kg 1.7 25 a 11 a kg 0.740 modello d - con una sola bobina per servizio intermittente

FAMILY D - DS 50

C.E.I. srl

SINGLE COIL SOLENOID FOR INTERMITTENT DUTY

INTERNAL SPRING 5M1WIRE DIAMETER SPRING 1

Kg 0.3 Kg 1.5

INTERNAL SPRING 5M2WIRE DIAMETER SPRING1.25

Kg 0.4 Kg 2.5

ELECTRIC CIRCUITS FOR DIESEL ENGINES

SERIES D INTERMITTENT

ELECTRIC CIRCUIT FOR INTERMITTENT DUTYThe solenoid connection is not conditioned by the polarity(+ and -).

ELECTRICALCONNECTIONS

OPTIONAL SPRINGS

ENGINE WITH INJECTION PUMP NORMALLY OPENENGINE SHUTDOWN BY SOLENOID ENERGIZINGINTERMITTENT DUTY

FOR STOP

EXAMPLE OF APPLICATION

STOP

SHUTDOWN LEVER TRAVEL

RUNNINGPOSITION

END-OF-STROKE

BY FASTON FASTON

CONNECTIONS

BY CABLES FRED CABLES

L = 200 mm

30°

Ø 6

Ø 6

30°

ACCESSORIES WITH M6 THREAD

PW6THREADED DOWELM6 - 1/4 UNF L = 38 mm

P6 THREADED DOWELL = 45 mm

CLE6UNI CLEVIS

SM6AXIAL ARTICULATEDJOINT

IM690° ARTICULATEDJOINT

AM6AXIAL ARTICULATED JOINT

C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

e-mail: [email protected] www.cei-italy.it

Page 15: FAMILY 50 - cei-italy.com rev0 ENG.pdf · 50 50 mm 40 mm kg 4.3 27 a 14.5 a kg 1.170 40 40 mm 40 mm kg 1.7 25 a 11 a kg 0.740 modello d - con una sola bobina per servizio intermittente

FAMILY D - DS 46

C.E.I. srl

Rated voltage 12 V DC 24 V DC Pull current 27 A 13 A Duty service Intermittent Stroke 26 mm Force at starting 7 Kg Windings insulation class H (180° C) Ambient temperature -40° C ÷ 120° C Weight 0.74 Kg

SPECIFICATIONS

00.4

0.6

0.8

1.0

1.2

25 50 75 100 125 °C

FORCE VARIATION COEFFICIENT ACCORDINGWITH AMBIENT TEMPERATURE

AMBIENT TEMPERATURE

Versions Voltages Circuits Brackets Optional Springs Electrical connections

D46 pull action 1 = 12 V DC Series D A M1 Standard Cables DS46 pull-push action 2 = 24 V DC C M2

SINGLE COIL SOLENOID FOR INTERMITTENT DUTY

RUNNINGPOSITION

BRACKET A BRACKET

C

AVAILABLE OPTIONSThe desired model has to be defined choosing one option in every column, building in this way the solenoid code.

C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

e-mail: [email protected] www.cei-italy.it

OPERATIONThe single coil Elettrostart solenoids are for intermittent duty provinding high FORCE-STROKE pick-up. These solenoids are used to stop diesel engines when energized by actuating the fuel supply lever. The solenoid is de-energized when the engine is running, only in the stop phase it is energized cutting off the fuel flow.Due to its high operating power the energized time must not exceed one minute, while the de-energized time between two energizing phases must be long enough for the solenoid to cool down.

A

C

VERSIONDS

Ø46

26 mm26 mm

FOR PULLACTION

FOR PUSHACTION

153

M6x20

M6x10

Ø4663

97

26

2.5577

26

M6x20

51

59 38-64 Ø 7

78 63,5

M6x203

Ø 46

5

10

15DIAGRAM OF FORCES AND STROKESForce (Kg)

0 4 8 12 16 20 24 28Stroke (mm)

Kg 7 (N68)

1 Kg = 9.81 Newtons

0 10 20 30 40

5

10

15DIAGRAMMA FORZA-CORSAForza (Kg)

Corsa (mm)

Kg 4.3 (N42)

1 Kg = 9.81 Newtons

Page 16: FAMILY 50 - cei-italy.com rev0 ENG.pdf · 50 50 mm 40 mm kg 4.3 27 a 14.5 a kg 1.170 40 40 mm 40 mm kg 1.7 25 a 11 a kg 0.740 modello d - con una sola bobina per servizio intermittente

FAMILY D - DS 46

C.E.I. srl

SINGLE COIL SOLENOID FOR INTERMITTENT DUTY

INTERNAL SPRING 5M1 WIRE DIAMETER SPRING 1

Kg 0.700 Kg 1.5

INTERNAL SPRING 5M2 WIRE DIAMETER SPRING 1.25

Kg 1.100 Kg 2.5

ELECTRIC CIRCUITS FOR DIESEL ENGINES

ACCESSORIES WITH M6 THREAD

SERIES D INTERMITTENT

ELECTRIC CIRCUIT FOR INTERMITTENT DUTYThe solenoid connection is not conditioned by the polarity(+ and --).

ELECTRICALCONNECTIONS

OPTIONAL SPRINGS

ENGINE WITH INJECTION PUMP NORMALLY OPENENGINE SHUTDOWN BY SOLENOID ENERGIZINGINTERMITTENT DUTY

FOR STOP

EXAMPLE OF APPLICATION

STOP

SHUTDOWN LEVER TRAVEL

RUNNINGPOSITION

END-OF-STROKE

BY CABLES

RED CABLES

L = 150 mm

C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

e-mail: [email protected] www.cei-italy.it

30°

Ø 6

Ø 6

30°PW6THREADED DOWELM6 - 1/4 UNF L = 38 mm

P6 THREADED DOWELL = 45 mm

CLE6UNI CLEVIS

SM6AXIAL ARTICULATEDJOINT

IM690° ARTICULATEDJOINT

AM6AXIAL ARTICULATED JOINT

Page 17: FAMILY 50 - cei-italy.com rev0 ENG.pdf · 50 50 mm 40 mm kg 4.3 27 a 14.5 a kg 1.170 40 40 mm 40 mm kg 1.7 25 a 11 a kg 0.740 modello d - con una sola bobina per servizio intermittente

FAMILY D - DS 60

C.E.I. srl

A

B

VERSIONDS

Rated voltage 12 V DC 24 V DC Pull current 37 A 20 A Duty service Intermittent Stroke 50 mm Force at starting 8.4 Kg Windings insulation class H (180° C) Ambient temperature -40° C ÷ 120° C Weight 1.83 Kg

SPECIFICATIONS

00.4

0.6

0.8

1.0

1.2

25 50 75 100 125 °C

FORCE VARIATION COEFFICIENT ACCORDINGWITH AMBIENT TEMPERATURE

AMBIENT TEMPERATURE

Versions Voltages Circuits Brackets Optional Springs Electrical connections D6 pull action 1 = 12 V DC 1 = Series D A M1 Standard Faston DS6 pull-push action 2 = 24 V DC B F = Cables

BRACKET A BRACKETB

63

46 38 2.5

33

M8x20

M8x20

30 124 ÷ 74

Ø 7.3

Ø 60 Ø 60

Ø 60

93 5090 ÷ 404Ø 8.5

21

70

44PUSH ACTION, AND-OF-STROKEBRACKETS A, B

50

35

M6

93

219

DIAGRAM OF FORCES AND STROKES

252015105

Force (Kg)

0 10 20 30 40 50Stroke (mm)

Kg 8.4 (N82)

0 10 20 30 40

5

10

15DIAGRAMMA FORZA-CORSAForza (Kg)

Corsa (mm)

Kg 4.3 (N42)

1 Kg = 9.81 Newtons

OPERATIONThe single coil Elettrostart solenoids are for intermittent duty provinding high FORCE-STROKE pick-up. These solenoids are used to stop diesel engines when energized by actuating the fuel supply lever. The solenoid is de-energized when the engine is running, only in the stop phase it is energized cutting off the fuel flow.Due to its high operating power the energized time must not exceed one minute, while the de-energized time between two energizing phases must be long enough for the solenoid to cool down.

SINGLE COIL SOLENOID FOR INTERMITTENT DUTY

RUNNINGPOSITION

C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

e-mail: [email protected] www.cei-italy.it

AVAILABLE OPTIONSThe desired model has to be defined choosing one option in every column, building in this way the solenoid code.

Page 18: FAMILY 50 - cei-italy.com rev0 ENG.pdf · 50 50 mm 40 mm kg 4.3 27 a 14.5 a kg 1.170 40 40 mm 40 mm kg 1.7 25 a 11 a kg 0.740 modello d - con una sola bobina per servizio intermittente

FAMILY D - DS 60

C.E.I. srl

SINGLE COIL SOLENOID FOR INTERMITTENT DUTY

INTERNAL SPRING 6M1

Kg 0.500 Kg 1.5

ELECTRIC CIRCUITS FOR DIESEL ENGINES

SERIES D INTERMITTENT

ELECTRIC CIRCUIT FOR INTERMITTENT DUTYThe solenoid connection is not conditioned by the polarity(+ and -).

ELECTRICALCONNECTIONS

OPTIONAL SPRING

ENGINE WITH INJECTION PUMP NORMALLY OPENENGINE SHUTDOWN BY SOLENOID ENERGIZINGINTERMITTENT DUTY

FOR STOP

EXAMPLE OF APPLICATION

STOP

SHUTDOWN LEVER TRAVEL

RUNNINGPOSITION

END-OF-STROKE

BY FASTON FASTON

CONNECTIONS

BY CABLES FRED CABLES

L = 200 mm

30°Ø 8

Ø 8

ACCESSORIES WITH M8 THREAD

CLE8UNI CLEVIS

SM8AXIAL ARTICULATEDJOINT

P8THREADED DOWELL = 45 mm

IM890° ARTICULATEDJOINT

C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

e-mail: [email protected] www.cei-italy.it

Page 19: FAMILY 50 - cei-italy.com rev0 ENG.pdf · 50 50 mm 40 mm kg 4.3 27 a 14.5 a kg 1.170 40 40 mm 40 mm kg 1.7 25 a 11 a kg 0.740 modello d - con una sola bobina per servizio intermittente

MODELLO MODEL ES 50 “SPECIAL”

SERIE SERIES 1 ES511AM4TG 12 V C.C.SERIE SERIES 1 ES521AM4TG 24 V C.C.SERIE SERIES 2 ES512AM4TG 12 V C.C.SERIE SERIES 2 ES522AM4TG 24 V C.C.SERIE SERIES 3 ES513AM4TG 12 V C.C.SERIE SERIES 3 ES523AM4TG 24 V C.C.

Fili Cables L = 200 mm

01234

56789

10111213141516

32 24 16 8 0

kg

mm

FORZA FORCE

FORZA MAGNETICAMAGNETIC FORCEFORZA MAGNETICAMAGNETIC FORCE

FORZA DELLA MOLLA

FORCE OF SPRINGFORZA DELLA MOLLA

FORCE OF SPRING

02468

101214161820222426283032

32 24 16 8 0

kg

mm

FORZA FORCE

FORZA MAGNETICAMAGNETIC FORCE

FORZA DELLA MOLLA

FORCE OF SPRING

FORZA MAGNETICAMAGNETIC FORCE

FORZA DELLA MOLLA

FORCE OF SPRING

■ FORZA MAGNETICA A INIZIO CORSA (32 mm) Kg 7 BOBINA DI POTENZA MAGNETIC FORCE AT START OF STROKE (32 mm) Kg 7 PULL COIL

■ FORZA MAGNETICA DI MANTENIMENTO A CONTATTO (A FINE CORSA) Kg 18 HOLDING MAGNETIC FORCE ON DIRECT CONTACT (AT END OF STROKE) Kg 18 HOLD COIL

■ FORZA MECCANICA DELLA MOLLA A INIZIO CORSA Kg 4.2 MECHANICAL FORCE OF THE SPRING AT START OF STROKE Kg 4.2

■ FORZA MECCANICA DELLA MOLLA IN COMPRESSIONE Kg 6 MECHANICAL FORCE OF THE SPRING IN COMPRESSION Kg 6

BOBINA DI MANTENIMENTO

ESEMPIO DI CORSA DI 32 mm IN TRAZIONE O SPINTA EXAMPLE OF STROKE OF 32 mm FOR PULL OR PUSH

82 mm

Ø 50 mm

PER AZIONE DI SPINTAFOR PUSH ACTION

PER AZIONE DI TRAZIONEFOR PULL ACTION

C.E.I. srl

C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

e-mail: [email protected] www.cei-italy.it

Page 20: FAMILY 50 - cei-italy.com rev0 ENG.pdf · 50 50 mm 40 mm kg 4.3 27 a 14.5 a kg 1.170 40 40 mm 40 mm kg 1.7 25 a 11 a kg 0.740 modello d - con una sola bobina per servizio intermittente

MODELLO MODEL ES 60 “SPECIAL”

SERIE SERIES 1 ES611AM3TG 12 V C.C.SERIE SERIES 1 ES621AM3TG 24 V C.C.SERIE SERIES 2 ES612AM3TG 12 V C.C.SERIE SERIES 2 ES622AM3TG 24 V C.C.SERIE SERIES 3 ES613AM3TG 12 V C.C.SERIE SERIES 3 ES623AM3TG 24 V C.C.

Fili Cables L = 200 mm

01234

56789

10111213141516

32 24 16 8 0

kg

mm

FORZA FORCE

FORZA MAGNETICAMAGNETIC FORCEFORZA MAGNETICAMAGNETIC FORCE

FORZA DELLA MOLLA

FORCE OF SPRINGFORZA DELLA MOLLA

FORCE OF SPRING

02468

101214161820222426283032

32 24 16 8 0

kg

mm

FORZA FORCE

FORZA MAGNETICAMAGNETIC FORCE

FORZA DELLA MOLLA

FORCE OF SPRING

FORZA MAGNETICAMAGNETIC FORCE

FORZA DELLA MOLLA

FORCE OF SPRING

■ FORZA MAGNETICA A INIZIO CORSA (32 mm) Kg 10 BOBINA DI POTENZA MAGNETIC FORCE AT START OF STROKE (32 mm) Kg 10 PULL COIL

■ FORZA MAGNETICA DI MANTENIMENTO A CONTATTO (A FINE CORSA) Kg 25 HOLDING MAGNETIC FORCE ON DIRECT CONTACT (AT END OF STROKE) Kg 25 HOLD COIL

■ FORZA MECCANICA DELLA MOLLA A INIZIO CORSA Kg 5 MECHANICAL FORCE OF THE SPRING AT START OF STROKE Kg 5

■ FORZA MECCANICA DELLA MOLLA IN COMPRESSIONE Kg 12 MECHANICAL FORCE OF THE SPRING IN COMPRESSION Kg 12

BOBINA DI MANTENIMENTO

ESEMPIO DI CORSA DI 32 mm IN TRAZIONE O SPINTA EXAMPLE OF STROKE OF 32 mm FOR PULL OR PUSH

90 mm

Ø 60mm

PER AZIONE DI SPINTAFOR PUSH ACTION

PER AZIONE DI TRAZIONEFOR PULL ACTION

C.E.I. srl

C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

e-mail: [email protected] www.cei-italy.it

Page 21: FAMILY 50 - cei-italy.com rev0 ENG.pdf · 50 50 mm 40 mm kg 4.3 27 a 14.5 a kg 1.170 40 40 mm 40 mm kg 1.7 25 a 11 a kg 0.740 modello d - con una sola bobina per servizio intermittente

MAX FREQUENZE DI UTILIZZOUso continuo: 3 cicli/minutoUso intermittente: 10 cicli/minuto (max 5 min.)

MAX ON-OFF DUTY CYCLESContinuous: 3 cycles/minuteIntermittent: 10 cycles/minute (max 5 min.)

DESCRIZIONEL’IE04 è un interruttore elettronico statico temporizzato con un circuito unico adeguato per 12 e 24 Volts. E’ adatto per il comando di ELETTROSTART doppia bobina con circuito elet-trico SERIE 3 senza interruttore impiegati per lo stop e per le accelerazioni dei motori diesel.Esso alimenta contemporaneamente le due bobine (PULL e HOLD) e dopo 500 millisecondi disinserisce la bobina PULL evitando il suo surriscaldamento.La sua applicazione presenta vantaggi meccanici ed elettrici:•Incasodierrataregistrazioneobloccodeileveraggirimane

inserita la sola bobina di mantenimento evitando il danneg-giamento del solenoide.

•Sostituiscel’interruttoreinternodelsolenoidepocoadattoinambienti polverosi o salini (grazie alla sua costruzione sta-gna) e nelle applicazioni con accelerazioni ripetute, garan-tendo una maggiore affidabilità e durata del solenoide.

•Di dimensioni e peso contenuti, può essere agevolmenteposizionato in qualsiasi punto del motore.

SPECIFICATIONThe IE04 is a timed static electronic switch with a single circuit suitable for 12 and 24 V. It is designed for control of dual coil ELETTROSTART with SERIES 3 electrical circuit without switch, used for the shutdown and acceleration of diesel engines. It supplies simultaneously the two coils (PULL and HOLD), and after 500 milliseconds it de-energizes the PULL coil, thus preventing it from overheating. Its application presents both mechanical and electrical advantages:•In theeventof incorrectadjustmentorblockingof thecom-

pound levers, only the HOLD coil remains energized, so preventing damage to the solenoid;

• It replaces the internal switchof the solenoidwhich is notvery suitable industyor salineenvironments (thanks to itsperfectly tight construction) and in applications with involving repeated acceleration, and thus guarantees a greater reli-ability and longer service of the solenoid;

•Sincethedimensionsandweightarereduced,itcanbeeasilypositioned in any point of the engine.

interruttore elettronico statico temporizzatoTIMED sTaTIc ElEcTronIc swITch

scHema - esempioarranGEMEnT - EXaMPlE

SPECIFICHEVoltaggio: 12-24 V ±10%Max voltaggio non ripetitivo: 100 VMax corrente: 95 ACavi: 2,5 mm2 L = 300 mmPeso: 130 g

SPECIFICATIONSVoltage: 12-24 V ±10%Max voltage not repetitive: 100 VMax current: 95 ACables: 2,5 mm2 L = 300 mmWeight: 130 g

Possibilità di saldare i cavi sull’Elettrostart senza montare il connettore.The cables can be welded to the Elettrostart avoiding the connector.

Interruttore IE04

c.e.i. srl

c o s t r u z i o n i e l e t t r o m a G n e t i c H e i n D u s t r i a l iCORSO PRIMO LEVI, 7 - 10098 RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

e-mail: [email protected] www.cei-italy.it