Familiarization with iXSforall Equipment
Transcript of Familiarization with iXSforall Equipment
Familiarization with iXSforall Equipment
o OPTICAL LINE TERMINAL (OLT)
o EoC MASTER
o EoC MASTER AMPLIFIER
o EoC SLAVE (MODEM)
OPTICAL LINE TERMINAL (OLT)
o OPTICAL LINE TERMINAL (OLT) - INDOOR
o OPTICAL LINE TERMINAL (OLT) - OUTDOOR
OPTICAL LINE TERMINAL (OLT)
- INDOOR
OPTICAL LINE TERMINAL (OLT) - INDOOR
OPTICAL LINE TERMINAL (OLT) - INDOOR
How to connect an Optical Line Terminal (OLT)-Indoor?
EPON Plate (EP4) LED Indicators
OPTICAL LINE TERMINAL (OLT)
- OUTDOOR
OPTICAL LINE TERMINAL (OLT) - OUTDOOR
How to connect an Optical Line Terminal (OLT)-Outdoor?
MEDIA CONVERTER
How to connect an Optical Line Terminal (OLT)-Outdoor?
OPTICAL NETWORK UNIT (ONU)
EoC MASTER
o ANM6004B-1U [1 Output]
o ANM6004B-2U [2 Output]
o ANM6004B-3U [3 Output]
o ANM6004B-4U [4 Output]
EoC MASTER ANM6004B-XU
ANM6004B-1U ANM6004B-2U
ANM6004B-3U ANM6004B-4U
EoC MASTER
o ANM6004B-1U [1 Output]
o ANM6004B-2U [2 Output]
o ANM6004B-3U [3 Output]
o ANM6004B-4U [4 Output]
oANM6004B-4U
EoC MASTER ANM6004B-4U
EoC MASTER ANM6004B-4U
EoC MASTER ANM6004B-4U
HOW TO CONNECT A MASTER?
EoC MASTER AMPLIFIER
o ANM6004B-2 [1 Output]
EoC MASTER AMPLIFIER ANM6004B-2
EoC MASTER AMPLIFIER ANM6004B-2
EoC MASTER AMPLIFIER ANM6004B-2
HOW TO CONNECT A MASTER AMPLIFIER?
WHAT DOES RFIN AND OUT MEANS?
WHAT DOES RFIN AND OUT MEANS IF CONFIGURED AS MASTER / SLAVE?
MASTER SLAVE
EoC MODULE LED INDICATOR Configuration: MASTER Configuration: SLAVE
NETWORK SWITCH & ONU LED INDICATOR
NOTE: >> ONU is not connected to OLT If LOS LED indicator is blinking. >> ONU is connected to OLT if PON LED Indicator is steady.
Difference between Master & Master Amplifier
Master
Master Amplifier
Has ONU and is directly connected to OLT Transmission medium (Input) is Fiber Optic Cable
Without ONU. It is cascaded to a Master
EoC modules are all configured as a Master
Transmission medium (Input) is Coaxial Cable One EoC module is configured as Slave and the rest are configured as Master. Minimum of 2 EoC Modules
Bandwidth is dependent on the capacity of the PON
Bandwidth is dependent on the capacity of the EoC Module of the Master on which it is cascaded
How to Access a Master / Master Amplifier?
o IP Address [192.168.1.254] o Role [Administrator / Read Only] o Username [admin] o Password [admin]
EoC Web Management [Home Page]
[System Manage] [Device Manage] [System Setup] [EoC Manage] [Advanced Settings]
o System Info o Ports o Save Config o CNU List o Relay Setting
EoC Web Management [System Manage]
o System Info
EoC Web Management [Device Manage]
o Ports
EoC Web Management [EoC Manage]
o CNU List
EoC Web Management [Advanced Settings]
o Relay Setting o Port: Cab 0/1 (Slave)
o Relay Setting o Port: Cab 0/2 (Master)
EoC Web Management [Advanced Settings]
o Relay Setting o Port: Cab 0/3 (No EoC Module detected)
EoC Web Management [Advanced Settings]
o Relay Setting o Port: Cab 0/4 (No EoC Module detected)
EoC Web Management [Advanced Settings]
o Save Config
EoC Web Management [Advanced Settings]
EoC SLAVE (MODEM)
o ANS4003WV
EoC SLAVE – MODEM ANS4003WV
MODEM MOUNTING TYPES
EoC SLAVE – MODEM ANS4003WV
HOW MODEM WORKS?
MODEM LED INDICATORS
o IP Address: 192.168.1.1 o Username: useradmin o Password: wdrlec
How to Access a Modem?
Web Management [Wireless Settings]
PON + EoC
>> PON (Passive Optical Network) >> EoC (Ethernet over Coax)
Note: Optical Network Unit (ONU) requires a minimum received optical signal of -27dBm