Familiarization with iXSforall Equipment

47
Familiarization with iXSforall Equipment o OPTICAL LINE TERMINAL (OLT) o EoC MASTER o EoC MASTER AMPLIFIER o EoC SLAVE (MODEM)

Transcript of Familiarization with iXSforall Equipment

Page 1: Familiarization with iXSforall Equipment

Familiarization with iXSforall Equipment

o OPTICAL LINE TERMINAL (OLT)

o EoC MASTER

o EoC MASTER AMPLIFIER

o EoC SLAVE (MODEM)

Page 2: Familiarization with iXSforall Equipment

OPTICAL LINE TERMINAL (OLT)

o OPTICAL LINE TERMINAL (OLT) - INDOOR

o OPTICAL LINE TERMINAL (OLT) - OUTDOOR

Page 3: Familiarization with iXSforall Equipment

OPTICAL LINE TERMINAL (OLT)

- INDOOR

Page 4: Familiarization with iXSforall Equipment

OPTICAL LINE TERMINAL (OLT) - INDOOR

Page 5: Familiarization with iXSforall Equipment

OPTICAL LINE TERMINAL (OLT) - INDOOR

Page 6: Familiarization with iXSforall Equipment

How to connect an Optical Line Terminal (OLT)-Indoor?

Page 7: Familiarization with iXSforall Equipment

EPON Plate (EP4) LED Indicators

Page 8: Familiarization with iXSforall Equipment

OPTICAL LINE TERMINAL (OLT)

- OUTDOOR

Page 9: Familiarization with iXSforall Equipment

OPTICAL LINE TERMINAL (OLT) - OUTDOOR

Page 10: Familiarization with iXSforall Equipment

How to connect an Optical Line Terminal (OLT)-Outdoor?

MEDIA CONVERTER

Page 11: Familiarization with iXSforall Equipment

How to connect an Optical Line Terminal (OLT)-Outdoor?

OPTICAL NETWORK UNIT (ONU)

Page 12: Familiarization with iXSforall Equipment

EoC MASTER

o ANM6004B-1U [1 Output]

o ANM6004B-2U [2 Output]

o ANM6004B-3U [3 Output]

o ANM6004B-4U [4 Output]

Page 13: Familiarization with iXSforall Equipment

EoC MASTER ANM6004B-XU

ANM6004B-1U ANM6004B-2U

ANM6004B-3U ANM6004B-4U

Page 14: Familiarization with iXSforall Equipment

EoC MASTER

o ANM6004B-1U [1 Output]

o ANM6004B-2U [2 Output]

o ANM6004B-3U [3 Output]

o ANM6004B-4U [4 Output]

oANM6004B-4U

Page 15: Familiarization with iXSforall Equipment

EoC MASTER ANM6004B-4U

Page 16: Familiarization with iXSforall Equipment

EoC MASTER ANM6004B-4U

Page 17: Familiarization with iXSforall Equipment

EoC MASTER ANM6004B-4U

Page 18: Familiarization with iXSforall Equipment

HOW TO CONNECT A MASTER?

Page 19: Familiarization with iXSforall Equipment

EoC MASTER AMPLIFIER

o ANM6004B-2 [1 Output]

Page 20: Familiarization with iXSforall Equipment

EoC MASTER AMPLIFIER ANM6004B-2

Page 21: Familiarization with iXSforall Equipment

EoC MASTER AMPLIFIER ANM6004B-2

Page 22: Familiarization with iXSforall Equipment

EoC MASTER AMPLIFIER ANM6004B-2

Page 23: Familiarization with iXSforall Equipment

HOW TO CONNECT A MASTER AMPLIFIER?

Page 24: Familiarization with iXSforall Equipment

WHAT DOES RFIN AND OUT MEANS?

Page 25: Familiarization with iXSforall Equipment

WHAT DOES RFIN AND OUT MEANS IF CONFIGURED AS MASTER / SLAVE?

MASTER SLAVE

Page 26: Familiarization with iXSforall Equipment

EoC MODULE LED INDICATOR Configuration: MASTER Configuration: SLAVE

Page 27: Familiarization with iXSforall Equipment

NETWORK SWITCH & ONU LED INDICATOR

NOTE: >> ONU is not connected to OLT If LOS LED indicator is blinking. >> ONU is connected to OLT if PON LED Indicator is steady.

Page 28: Familiarization with iXSforall Equipment

Difference between Master & Master Amplifier

Master

Master Amplifier

Has ONU and is directly connected to OLT Transmission medium (Input) is Fiber Optic Cable

Without ONU. It is cascaded to a Master

EoC modules are all configured as a Master

Transmission medium (Input) is Coaxial Cable One EoC module is configured as Slave and the rest are configured as Master. Minimum of 2 EoC Modules

Bandwidth is dependent on the capacity of the PON

Bandwidth is dependent on the capacity of the EoC Module of the Master on which it is cascaded

Page 29: Familiarization with iXSforall Equipment

How to Access a Master / Master Amplifier?

o IP Address [192.168.1.254] o Role [Administrator / Read Only] o Username [admin] o Password [admin]

Page 30: Familiarization with iXSforall Equipment

EoC Web Management [Home Page]

[System Manage] [Device Manage] [System Setup] [EoC Manage] [Advanced Settings]

o System Info o Ports o Save Config o CNU List o Relay Setting

Page 31: Familiarization with iXSforall Equipment

EoC Web Management [System Manage]

o System Info

Page 32: Familiarization with iXSforall Equipment

EoC Web Management [Device Manage]

o Ports

Page 33: Familiarization with iXSforall Equipment

EoC Web Management [EoC Manage]

o CNU List

Page 34: Familiarization with iXSforall Equipment

EoC Web Management [Advanced Settings]

o Relay Setting o Port: Cab 0/1 (Slave)

Page 35: Familiarization with iXSforall Equipment

o Relay Setting o Port: Cab 0/2 (Master)

EoC Web Management [Advanced Settings]

Page 36: Familiarization with iXSforall Equipment

o Relay Setting o Port: Cab 0/3 (No EoC Module detected)

EoC Web Management [Advanced Settings]

Page 37: Familiarization with iXSforall Equipment

o Relay Setting o Port: Cab 0/4 (No EoC Module detected)

EoC Web Management [Advanced Settings]

Page 38: Familiarization with iXSforall Equipment

o Save Config

EoC Web Management [Advanced Settings]

Page 39: Familiarization with iXSforall Equipment

EoC SLAVE (MODEM)

o ANS4003WV

Page 40: Familiarization with iXSforall Equipment

EoC SLAVE – MODEM ANS4003WV

Page 41: Familiarization with iXSforall Equipment

MODEM MOUNTING TYPES

Page 42: Familiarization with iXSforall Equipment

EoC SLAVE – MODEM ANS4003WV

Page 43: Familiarization with iXSforall Equipment

HOW MODEM WORKS?

Page 44: Familiarization with iXSforall Equipment

MODEM LED INDICATORS

Page 45: Familiarization with iXSforall Equipment

o IP Address: 192.168.1.1 o Username: useradmin o Password: wdrlec

How to Access a Modem?

Page 46: Familiarization with iXSforall Equipment

Web Management [Wireless Settings]

Page 47: Familiarization with iXSforall Equipment

PON + EoC

>> PON (Passive Optical Network) >> EoC (Ethernet over Coax)

Note: Optical Network Unit (ONU) requires a minimum received optical signal of -27dBm