Failure Analysis Study of a Cracked Superheater Outlet … A detailed failure analysis study has...
21
© Riley Power Inc., 2012 www.babcockpower.com Failure Analysis Study of a Cracked Superheater Outlet Header by Robert L. Roland CAJUN ELECTRIC POWER COOPERATIVE, INC. Baton Rouge, Louisiana James P. King a Babcock Power Inc. company (formerly Riley Stoker Corporation) David P. Kalmanovitch a Babcock Power Inc. company (formerly Riley Stoker Corporation) Presented at City Public Service San Antonio January 18-20, 1994 San Antonio, Texas Technical Publication RST-124 RILEY POWER INC. RILEY POWER INC.
Transcript of Failure Analysis Study of a Cracked Superheater Outlet … A detailed failure analysis study has...
© Riley Power Inc., 2012 www.babcockpower.com
Failure Analysis Studyof a Cracked Superheater Outlet Header
by
Robert L. RolandCAJUN ELECTRIC POWER COOPERATIVE, INC.
Baton Rouge, Louisiana
James P. King
a Babcock Power Inc. company(formerly Riley Stoker Corporation)
David P. Kalmanovitch
a Babcock Power Inc. company(formerly Riley Stoker Corporation)
Presented at City Public Service San Antonio
January 18-20, 1994San Antonio, Texas
Technical Publ icat ion
RST-124
RILEY POWER INC.
RILEY POWER INC.