FACADES - BRICK · panel thickness 1 4" - 14 hex head fasteners with washer horizontal support (not...

20
INDEX SHEET FACADES - BRICK KPV-DS-01-BRH C & I DISCLAIMER KPV-PJ-01-BRH EXPANDED PANEL JOINT KPV-PJ-02-BRH ENGAGED PANEL JOINT KPV-PJ-03-BRH INTERMEDIATE SUPPORT KPV-BS-01-BRH BASE DETAIL FLUSH KPV-BS-02-BRH BASE AT NOTCHED CONCRETE KPV-BS-03-BRH BASE AT OVERHANG KPV-OC-01-BRH OUTSIDE CORNER KPV-IC-01-BRH INSIDE CORNER KPV-FO-01-BRH FRAMED OPENING HEAD KPV-FO-02-BRH FRAMED OPENING JAMB KPV-FO-03-BRH FRAMED OPENING SILL KPV-SJ-01-BRH STACK JOINT KPV-PR-01-BRH PARAPET DETAIL KPV-LE-01-BRH LOW EAVE DETAIL KPV-RD-01-BRH RAKE DETAIL KPV-TP-01-BRH PANEL TERMINATION KPV-TL-01-BRH TRIM END LAP KPV-TL-02-BRH TRIM END LAP WITH HEMS L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg

Transcript of FACADES - BRICK · panel thickness 1 4" - 14 hex head fasteners with washer horizontal support (not...

Page 1: FACADES - BRICK · panel thickness 1 4" - 14 hex head fasteners with washer horizontal support (not by kingspan) 1" 6(7 .$55,(5 5$,/ ,1 %87

INDEX SHEET

FACADES - BRICK

KPV-DS-01-BRH C & I DISCLAIMER

KPV-PJ-01-BRH EXPANDED PANEL JOINT

KPV-PJ-02-BRH ENGAGED PANEL JOINT

KPV-PJ-03-BRH INTERMEDIATE SUPPORT

KPV-BS-01-BRH BASE DETAIL FLUSH

KPV-BS-02-BRH BASE AT NOTCHED CONCRETE

KPV-BS-03-BRH BASE AT OVERHANG

KPV-OC-01-BRH OUTSIDE CORNER

KPV-IC-01-BRH INSIDE CORNER

KPV-FO-01-BRH FRAMED OPENING HEAD

KPV-FO-02-BRH FRAMED OPENING JAMB

KPV-FO-03-BRH FRAMED OPENING SILL

KPV-SJ-01-BRH STACK JOINT

KPV-PR-01-BRH PARAPET DETAIL

KPV-LE-01-BRH LOW EAVE DETAIL

KPV-RD-01-BRH RAKE DETAIL

KPV-TP-01-BRH PANEL TERMINATION

KPV-TL-01-BRH TRIM END LAP

KPV-TL-02-BRH TRIM END LAP WITH HEMS

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg

Page 2: FACADES - BRICK · panel thickness 1 4" - 14 hex head fasteners with washer horizontal support (not by kingspan) 1" 6(7 .$55,(5 5$,/ ,1 %87

DISCLAIMER

DISCLAIMERS:

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED

COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

LOCATION OF VAPOR BARRIERS AND ASSOCIATED SEALANTS IN THESE DETAILS ARE BASED

ON TYPICAL DESIGN PRACTICES FOR MOST U.S. AND CANADIAN CLIMACTIC ZONES. (THE PRIMARY

VAPOR BARRIER IS PLACED ON THE "WARM" SIDE IN WINTER).

PROJECTS LOCATED IN AREAS SUBJECT TO EXTREME COLD AND/OR HIGH SNOW LOADS MAY

REQUIRE MODIFICATIONS TO THESE DETAILS - CONTACT KINGSPAN TECHNICAL SERVICES

FOR SPECIFIC PROJECT RECOMMENDATIONS.

ALL STRUCTURAL SUPPORTS ARE NOT BY KINGSPAN AND ARE SHOWN FOR CLARIFICATION AND

ILLUSTRATION PURPOSES ONLY.

WALL SYSTEM DEFLECTIONS ARE TO BE DETERMINED BY THE ENGINEER OF RECORD.

ALL STRUCTURAL SUPPORTS ARE NOT BY KINGSPAN AND ARE SHOWN FOR CLARIFICATION AND

ILLUSTRATION PURPOSES ONLY.

CONTACT KINGSPAN TECHNICAL SERVICES FOR MAXIMUM ALLOWABLE PANEL SPANS

AND FASTENING PATTERNS.

FACADES - BRICK

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg

Page 3: FACADES - BRICK · panel thickness 1 4" - 14 hex head fasteners with washer horizontal support (not by kingspan) 1" 6(7 .$55,(5 5$,/ ,1 %87

1

4

" - 14 HEX HEAD

FASTENERS WITH WASHER

CONTINUOUS

BUTYL SEALANT

2" - 6"

42" COVERAGE (36", 30", & 24" OPTIONAL)

KS42SL

EXTERIOR FACE

INTERIOR FACE

SHADOWLINE

SHADOWLINE

FEMALE JOINTMALE JOINT

HORIZONTAL SUPPORT

(NOT BY KINGSPAN)

SET KARRIER™ RAIL IN BUTYL

SEALANT AT FASTENER

LOCATIONS

EXPANDED PANEL

JOINT

FACADES - BRICK

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg

Page 4: FACADES - BRICK · panel thickness 1 4" - 14 hex head fasteners with washer horizontal support (not by kingspan) 1" 6(7 .$55,(5 5$,/ ,1 %87

1"

MALE JOINTFEMALE JOINT

WALL PANEL INSTALLATION DIRECTION

EXPANSION

FASTENER

AS REQUIRED

1

4

" - 14 HEX HEAD

FASTENERS WITH WASHER

CONTINUOUS

BUTYL SEALANT

CONTINUOUS

BUTYL SEALANT

(OPTIONAL)

HORIZONTAL SUPPORT

(NOT BY KINGSPAN)

BRICK SUPPORT TRAY

SET KARRIER™ RAIL IN BUTYL

SEALANT AT FASTENER

LOCATIONS

CONTINUOUS KARRIER™ RAIL

(KARRIER™ RAIL AVAILABLE

IN 1"- 3" FACES)

#10 TEK FASTENER

ENGAGED PANEL

JOINT

FACADES - BRICK

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg

Page 5: FACADES - BRICK · panel thickness 1 4" - 14 hex head fasteners with washer horizontal support (not by kingspan) 1" 6(7 .$55,(5 5$,/ ,1 %87

PANEL

THICKNESS

1

4

" - 14 HEX HEAD

FASTENERS WITH WASHER

HORIZONTAL SUPPORT

(NOT BY KINGSPAN)

1"

SET KARRIER™ RAIL IN BUTYL

SEALANT AT FASTENER

LOCATIONS

EXPANSION FASTENER

AS REQUIRED

INSULATED

METAL

PANEL (IMP)

BENCHMARK THIN

BRICK

BRICK SUPPORT TRAY

#10 TEK FASTENER

CONTINUOUS

SUPPORT RAIL

1

1

8

"

MORTAR JOINT

INTERMEDIATE

SUPPORT

FACADES - BRICK

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg

Page 6: FACADES - BRICK · panel thickness 1 4" - 14 hex head fasteners with washer horizontal support (not by kingspan) 1" 6(7 .$55,(5 5$,/ ,1 %87

CONTINUOUS BUTYL SEALANT

BELOW BASE FLASHING

BASE FLASHING

FASTENER TO CONCRETE

(NOT BY KINGSPAN)

BASE ANGLE W/ MINIMUM 3"

VERT. LEG FOR PANEL

ATTACHMENT SET IN SEALANT

(NOT BY KINGSPAN)

1

4

" - 14 HEX HEAD FASTENERS

WITH WASHER

CONTINUOUS BUTYL

SEALANT BOTH SIDES OF

TRIM WITH MARRIAGE BEAD

TO VERTICAL PANEL JOINT

CONTINUOUS KARRIER™ RAIL

(KARRIER™ RAIL AVAILABLE

IN 1"- 3" FACES)

SET KARRIER™ RAIL IN BUTYL

SEALANT AT FASTENER

LOCATIONS

EXPANSION FASTENER

AS REQUIRED

BRICK SUPPORT

TRAY

BENCHMARK THIN

BRICK

MORTAR JOINT

BENCHMARK THIN

BRICK (BOTTOM COURSE

TRANSITION)

BASE DETAIL

FLUSH

FACADES - BRICK

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg

Page 7: FACADES - BRICK · panel thickness 1 4" - 14 hex head fasteners with washer horizontal support (not by kingspan) 1" 6(7 .$55,(5 5$,/ ,1 %87

CONTINUOUS BUTYL SEALANT

BELOW BASE FLASHING

FASTENER TO CONCRETE

(NOT BY KINGSPAN)

EXPANSION FASTENER

AS REQUIRED

1

4

" - 14 HEX HEAD FASTENERS

WITH WASHER

CONTINUOUS BUTYL

SEALANT BOTH SIDES OF

TRIM WITH MARRIAGE BEAD

TO VERTICAL PANEL JOINT

SET KARRIER™ RAIL IN BUTYL

SEALANT AT FASTENER

LOCATIONS

BASE ANGLE W/ MINIMUM 3"

VERT. LEG FOR PANEL

ATTACHMENT SET IN SEALANT

(NOT BY KINGSPAN)

CONTINUOUS BUTYL SEALANT

CONTINUOUS KARRIER™ RAIL

(KARRIER™ RAIL AVAILABLE

IN 1"- 3" FACES)

BASE FLASHING

BRICK SUPPORT

TRAY

BENCHMARK THIN

BRICK

MORTAR JOINT

BENCHMARK THIN

BRICK (BOTTOM COURSE

TRANSITION)

BASE AT NOTCHED

CONCRETE

FACADES - BRICK

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg

Page 8: FACADES - BRICK · panel thickness 1 4" - 14 hex head fasteners with washer horizontal support (not by kingspan) 1" 6(7 .$55,(5 5$,/ ,1 %87

FASTENER TO CONCRETE

(NOT BY KINGSPAN)

BASE FLASHING

1

4

" - 14 HEX HEAD FASTENERS

WITH WASHER

CONTINUOUS BUTYL

SEALANT BOTH SIDES OF

TRIM WITH MARRIAGE BEAD

TO VERTICAL PANEL JOINT

SET KARRIER™ RAIL IN BUTYL

SEALANT AT FASTENER

LOCATIONS

BASE ANGLE W/ MINIMUM 3"

VERT. LEG FOR PANEL

ATTACHMENT SET IN SEALANT

(NOT BY KINGSPAN)

CONTINUOUS BUTYL SEALANT

CONTINUOUS KARRIER™ RAIL

(KARRIER™ RAIL AVAILABLE

IN 1"- 3" FACES)

EXPANSION FASTENER

AS REQUIRED

BRICK SUPPORT

TRAY

BENCHMARK THIN

BRICK

MORTAR JOINT

BENCHMARK THIN

BRICK (BOTTOM COURSE

TRANSITION)

BASE AT OVERHANG

FACADES - BRICK

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg

Page 9: FACADES - BRICK · panel thickness 1 4" - 14 hex head fasteners with washer horizontal support (not by kingspan) 1" 6(7 .$55,(5 5$,/ ,1 %87

POP RIVETS

INSIDE CORNER TRIM

HORIZONTAL SUPPORT

(NOT BY KINGSPAN)

CONTINUOUS BUTYL

SEALANT

OUTSIDE CORNER TRIM

F.I.P. INSULATION

AS REQUIRED

(BY OTHERS)

3

4

" PHIL PAN HEAD

HAT CHANNEL SET IN

BUTYL SEALANT AT

FASTENER LOCATIONS

1

4

" - 14 HEX HEAD

FASTENERS

WITH WASHER

3

4

" PHIL PAN HEAD

1

4

" - 14 HEX HEAD

FASTENERS

WITH WASHER

HAT CHANNEL SET IN

BUTYL SEALANT AT

FASTENER LOCATIONS

POP RIVETS

1

4

" - 14 "LOW PROFILE

FASTENER W/ 1

1

8

"

BONDED WASHER

MORTAR JOINT

BRICK SUPPORT

TRAY

BENCHMARK THIN

BRICK

OUTSIDE CORNER

FACADES - BRICK

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg

Page 10: FACADES - BRICK · panel thickness 1 4" - 14 hex head fasteners with washer horizontal support (not by kingspan) 1" 6(7 .$55,(5 5$,/ ,1 %87

HORIZONTAL SUPPORT

(NOT BY KINGSPAN)

OUTSIDE CORNER TRIM

F.I.P. INSULATION

AS REQUIRED

(BY OTHERS)

1

4

" - 14 HEX HEAD

FASTENERS

WITH WASHER

1

4

" - 14 "LOW PROFILE

FASTENER W/ 1

1

8

"

BONDED WASHER

1

4

" - 14 "LOW PROFILE

FASTENER W/ 1

1

8

"

BONDED WASHER

POP RIVETS

3

4

" PHIL PAN HEAD

3

4

" PHIL PAN HEAD

POP RIVETS

INSIDE CORNER TRIM

1

4

" - 14 HEX HEAD

FASTENERS

WITH WASHER

CONTINUOUS BUTYL

SEALANT

CONTINUOUS BUTYL

SEALANT

HAT CHANNEL SET IN

BUTYL SEALANT AT

FASTENER LOCATIONS

HAT CHANNEL SET IN

BUTYL SEALANT AT

FASTENER LOCATIONS

BENCHMARK THIN BRICK

BRICK SUPPORT

TRAY

MORTAR JOINT

INSIDE CORNER

FACADES - BRICK

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg

Page 11: FACADES - BRICK · panel thickness 1 4" - 14 hex head fasteners with washer horizontal support (not by kingspan) 1" 6(7 .$55,(5 5$,/ ,1 %87

DOOR/WINDOW FRAME

(NOT BY KINGSPAN)

EXPOSED SEALANT

(NOT BY KINGSPAN)

1

4

" - 14 HEX HEAD FASTENERS

WITH WASHER

FRAMED OPENING

(NOT BY KINGSPAN)

CONTINUOUS KARRIER™ RAIL

(KARRIER™ RAIL AVAILABLE

IN 1"- 3" FACES)

EXPANSION

FASTENER

AS REQUIRED

CONTINUOUS BUTYL

SEALANT BOTH SIDES OF

TRIM WITH MARRIAGE BEAD

TO VERTICAL PANEL JOINT

DRIP FLASHING

BRICK SUPPORT

TRAY

BENCHMARK THIN

BRICK

MORTAR JOINT

FRAMED OPENING

HEAD

FACADES - BRICK

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg

Page 12: FACADES - BRICK · panel thickness 1 4" - 14 hex head fasteners with washer horizontal support (not by kingspan) 1" 6(7 .$55,(5 5$,/ ,1 %87

FRAMED OPENING

(NOT BY KINGSPAN)

DOOR/WINDOW FRAME

(NOT BY KINGSPAN)

EXPOSED SEALANT

(NOT BY KINGSPAN)

CONTINUOUS BUTYL SEALANT

1

4

" - 14 "LOW PROFILE"

THROUGH FASTENER

HAT CHANNEL SET IN

BUTYL SEALANT AT

FASTENER LOCATIONS

1

4

" - 14 HEX HEAD

FASTENERS

WITH WASHER

SEALANT

1

4

" - 14 THROUGH

FASTENER

BACKER ROD AND SEALANT

(NOT BY KINGSPAN)

FRAMED OPENING

JAMB

FACADES - BRICK

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg

Page 13: FACADES - BRICK · panel thickness 1 4" - 14 hex head fasteners with washer horizontal support (not by kingspan) 1" 6(7 .$55,(5 5$,/ ,1 %87

DOOR/WINDOW

FRAME

(NOT BY KINGSPAN)

EXPOSED SEALANT

(NOT BY KINGSPAN)

MITER CUT JOINTS

WHERE REQUIRED

SEALANT

1

4

" - 14 THROUGH

FASTENER

1

4

" - 14 HEX HEAD

FASTENERS

WITH WASHER

CONTINUOUS BUTYL

SEALANT BOTH SIDES OF

TRIM WITH MARRIAGE BEAD

TO VERTICAL PANEL JOINT

CONTINUOUS KARRIER™ RAIL

(KARRIER™ RAIL AVAILABLE

IN 1"- 3" FACES)

EXPANSION

FASTENER

AS REQUIRED

SILL TRIM

BRICK SUPPORT

TRAY

BENCHMARK THIN

BRICK

MORTAR JOINT

BENCHMARK THIN

BRICK SILL

FRAMED OPENING SILL

FACADES - BRICK

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg

Page 14: FACADES - BRICK · panel thickness 1 4" - 14 hex head fasteners with washer horizontal support (not by kingspan) 1" 6(7 .$55,(5 5$,/ ,1 %87

1

4

" - 14 HEX HEAD

FASTENERS

WITH WASHER

FASTENER AS REQUIRED

(NOT BY KINGSPAN)

CONTINUOUS BUTYL

SEALANT WITH MARRIAGE

BEAD TO VERTICAL PANEL

JOINT

1

4

" - 14 HEX HEAD

FASTENERS

WITH WASHER

HORIZONTAL SUPPORTS

(NOT BY KINGSPAN)

CONTINUOUS KARRIER™

RAIL (KARRIER™ RAIL

AVAILABLE IN 1"- 3" FACES)*

EXPANSION

FASTENER

AS REQUIRED

EXPANSION

FASTENER

AS REQUIRED

*NOTE: FIELD NOTCH KARRIER™ RAIL AS REQUIRED*

FIELD NOTCH KARRIER™ RAIL

AS REQUIRED AT STACK FLASHING/

STACK JOINT FOR OVERLAP

BRICK SUPPORT

TRAY

BENCHMARK THIN

BRICK

MORTAR JOINT

STACK JOINT

FACADES - BRICK

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg

Page 15: FACADES - BRICK · panel thickness 1 4" - 14 hex head fasteners with washer horizontal support (not by kingspan) 1" 6(7 .$55,(5 5$,/ ,1 %87

WRAP MEMBRANE

OVER BRICK FACE

(NOT BY KINGSPAN)

PARAPET BLOCKING

(NOT BY KINGSPAN)

FIP INSULATION

AS REQUIRED

MEMBRANE ROOF & PARAPET

BACKER (NOT BY KINGSPAN)

FASTENER TO

PARAPET

BACKER

(NOT BY KINGSPAN)

1

4

" - 14 HEX HEAD FASTENERS

WITH WASHER

EXPANSION

FASTENER

AS REQUIRED

CONTINUOUS BUTYL

SEALANT BOTH SIDES OF

TRIM WITH MARRIAGE BEAD

TO VERTICAL PANEL JOINT

CONTINUOUS KARRIER™

RAIL (KARRIER™ RAIL

AVAILABLE IN 1"- 3" FACES)

PARAPET ASSEMBLY

BRICK SUPPORT

TRAY

BENCHMARK THIN

BRICK

MORTAR JOINT

PARAPET DETAIL

FACADES - BRICK

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg

Page 16: FACADES - BRICK · panel thickness 1 4" - 14 hex head fasteners with washer horizontal support (not by kingspan) 1" 6(7 .$55,(5 5$,/ ,1 %87

EAVE STRUT

(NOT BY KINGSPAN)

REFER TO 900/1000 SERIES

ROOF PANEL DETAILS FOR

ADDITIONAL INFORMATION

FIP INSULATION

AS REQUIRED

1

4

" - 14 HEX HEAD FASTENERS

WITH WASHER

EXPANSION

FASTENER

AS REQUIRED

CONTINUOUS BUTYL

SEALANT BOTH SIDES OF

TRIM WITH MARRIAGE BEAD

TO VERTICAL PANEL JOINT

CONTINUOUS KARRIER™

RAIL (KARRIER™ RAIL

AVAILABLE IN 1"- 3" FACES)

BRICK SUPPORT

TRAY

BENCHMARK THIN

BRICK

MORTAR JOINT

FASTENER SHOULD

PENETRATE THE MORTAR

JOINTS BETWEEN THE

BRICK ENDS, NOT ABOVE

OR BELOW THE BRICKS

LOW EAVE DETAIL

FACADES - BRICK

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg

Page 17: FACADES - BRICK · panel thickness 1 4" - 14 hex head fasteners with washer horizontal support (not by kingspan) 1" 6(7 .$55,(5 5$,/ ,1 %87

RAKE ANGLE

(NOT BY KINGSPAN)

REFER TO 900/1000 SERIES

ROOF PANEL DETAILS FOR

ADDITIONAL INFORMATION

FIP INSULATION

AS REQUIRED

RAKE ANGLE

(NOT BY KINGSPAN)

EXPANSION

FASTENER

AS REQUIRED

1

4

" - 14 HEX HEAD FASTENERS

WITH WASHER

CONTINUOUS BUTYL

SEALANT BOTH SIDES OF

TRIM WITH MARRIAGE BEAD

TO VERTICAL PANEL JOINT

CONTINUOUS KARRIER™

RAIL (KARRIER™ RAIL

AVAILABLE IN 1"- 3" FACES)

BRICK SUPPORT

TRAY

BENCHMARK THIN

BRICK

MORTAR JOINT

FASTENER SHOULD

PENETRATE THE MORTAR

JOINTS BETWEEN THE

BRICK ENDS, NOT ABOVE

OR BELOW THE BRICKS

RAKE DETAIL

FACADES - BRICK

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg

Page 18: FACADES - BRICK · panel thickness 1 4" - 14 hex head fasteners with washer horizontal support (not by kingspan) 1" 6(7 .$55,(5 5$,/ ,1 %87

STRUCTURAL SUPPORTS

(NOT BY KINGSPAN)

BACKER ROD & SEALANT

(NOT BY KINGSPAN)

CAP TRIM

1

4

" - 14 HEX HEAD

FASTENERS WITH WASHER

CONTINUOUS BUTYL

SEALANT

HAT CHANNEL SET IN

BUTYL SEALANT AT

FASTENER LOCATIONS

1

4

" - 14 "LOW PROFILE

FASTENER W/ 1

1

8

"

BONDED WASHER

BACKER ROD AND SEALANT

BENCHMARK THIN

BRICK

BRICK SUPPORT

TRAY

PANEL TERMINATION

FACADES - BRICK

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg

Page 19: FACADES - BRICK · panel thickness 1 4" - 14 hex head fasteners with washer horizontal support (not by kingspan) 1" 6(7 .$55,(5 5$,/ ,1 %87

M

I

N

.

3

"

T

R

I

M

L

A

P

M

I

N

.

3

"

T

R

I

M

L

A

P

(2) BEADS

BUTYL SEALANT

TRIM END LAP

FACADES - BRICK

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg

Page 20: FACADES - BRICK · panel thickness 1 4" - 14 hex head fasteners with washer horizontal support (not by kingspan) 1" 6(7 .$55,(5 5$,/ ,1 %87

M

I

N

.

3

"

T

R

I

M

L

A

P

M

I

N

.

3

"

T

R

I

M

L

A

P

(2) BEADS

BUTYL SEALANT

FIELD NOTCH HEM(S)

AS REQUIRED

(NOT BY KINGSPAN)

TRIM END LAP

WITH HEMS

FACADES - BRICK

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg