Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June...
Transcript of Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June...
53-1004135-0730 June 2017
®
Fabric OSDocumentation Updates
Supporting Fabric OS 7.4.0Supporting Fabric OS 7.4.1 Supporting Fabric OS 7.4.2
©2017, Brocade Communications Systems, Inc. All Rights Reserved.
Brocade, the B-wing symbol, and MyBrocade are registered trademarks of Brocade Communications Systems, Inc., in the United States and in other countries. Other brands, product names, or service names mentioned of Brocade Communications Systems, Inc. are listed at http://www.brocade.com/en/legal/brocade-Legal-intellectual-property/brocade-legal-trademarks.html. Other marks may belong to third parties.
Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to this document at any time, without notice, and assumes no responsibility for its use. This informational document describes features that may not be currently available. Contact a Brocade sales office for information on feature and product availability. Export of technical data contained in this document may require an export license from the United States government.
The authors and Brocade Communications Systems, Inc. assume no liability or responsibility to any person or entity with respect to the accuracy of this document or any loss, cost, liability, or damages arising from the information contained herein or the computer programs that accompany it.
The product described by this document may contain open source software covered by the GNU General Public License or other open source license agreements. To find out which open source software is included in Brocade products, view the licensing terms applicable to the open source software, and obtain a copy of the programming source code, please visit http://www.brocade.com/support/oscd.
Brocade Communications Systems, Incorporated
Document History
Corporate and Latin American HeadquartersBrocade Communications Systems, Inc.130 Holger WaySan Jose, CA 95134 Tel: 1-408-333-8000 Fax: 1-408-333-8101 E-mail: [email protected]
Asia-Pacific HeadquartersBrocade Communications Systems China HK, Ltd.No. 1 Guanghua RoadChao Yang DistrictUnits 2718 and 2818Beijing 100020, ChinaTel: +8610 6588 8888Fax: +8610 6588 9999E-mail: [email protected]
European HeadquartersBrocade Communications Switzerland SàrlCentre SwissairTour B - 4ème étage29, Route de l'AéroportCase Postale 105CH-1215 Genève 15Switzerland Tel: +41 22 799 5640Fax: +41 22 799 5641E-mail: [email protected]
Asia-Pacific HeadquartersBrocade Communications Systems Co., Ltd. (Shenzhen WFOE)Citic PlazaNo. 233 Tian He Road NorthUnit 1308 – 13th FloorGuangzhou, ChinaTel: +8620 3891 2000Fax: +8620 3891 2111E-mail: [email protected]
Title Publication number Summary of changes Date
Fabric OS Documentation Updates 53-1004135-01 Updates for the following documents:• Fabric OS Command Reference• Fabric OS Message Reference• Fabric OS MIB Reference
January 2016
Fabric OS Documentation Updates 53-1004135-02 Updates for the following document:• Fabric OS Command Reference
February 2016
Fabric OS Documentation Updates 53-1004135-03 Updates for the following document:• Fabric OS Command Reference
February 2016
Fabric OS Documentation Updates 53-1004135-04 Updates for the following document:• Fabric OS Command Reference• Fabric OS Message Reference
October 2016
Fabric OS Documentation Updates 53-1004135-05 Updates for the following document:• Fabric OS Encryption
Administrator’s Guide
February 2017
Fabric OS Documentation Updates 53-1004135-06 Updates for the following document:• Fabric OS Command Reference• Fabric OS Message Reference• Fabric OS MIB Reference
April 2017
Fabric OS Documentation Updates 53-1004135-07 Updates for the following document:• Fabric OS Command Reference• Fabric OS Message Reference
June 2017
Title Publication number Summary of changes Date
Fabric OS Documentation Updates 353-1004135-07
4 Fabric OS Documentation Updates53-1004135-07
Contents
About This Document
How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
What’s new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Brocade Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Document feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Chapter 1 Fabric OS Command Reference
Documentation Updates for Fabric OS v7.4.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Updates to the "About This Document" chapter- - - - - - - - - - - - - - - - - - - - - - - 11
Updates to Chapter 2, Fabric OS Commands- - - - - - - - - - - - - - - - - - - - - - - - - 11
agShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11configure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13diagStatus. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14nsShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14openSource. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15sfpShow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Updates to Appendix A, Command Availability - - - - - - - - - - - - - - - - - - - - - - - - 17
Documentation Updates for Fabric OS v7.4.x . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17portcmd. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17portshow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17ficoncupset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18portcfgshow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18portCfgFillword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Documentation Updates for Fabric OS v7.4.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18ag. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19portCfgNonDfe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Chapter 2 Fabric OS Message Reference
Documentation updates for Fabric OS v7.4.0, v7.4.1, and v7.4.2 . . . . . . . . . . . . 21Updates to Chapter 1, Introduction to System Messages - - - - - - - - - - - - - - - 21
Updates to Chapter 5, Fabric OS System Messages - - - - - - - - - - - - - - - - - - - 21
FV-3014. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22MS-1021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22BL-1080. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22C2-1034 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23C2-1035 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23C3-1041 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Fabric OS Documentation Updates 553-1004135-07
C3-1042 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24EM-1226 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24FCPH-1007 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24FCPH-1008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25FCPH-1009 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25FV-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26HIL-1109 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26RAS-2010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26RAS-2011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26SULB-1060 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27SWCH-1031 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27TS-1011. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Chapter 3 Fabric OS MIB Reference
Documentation updates for Fabric OS v7.4.0 and later . . . . . . . . . . . . . . . . . . . . 29Updates to Chapter 1, Understanding Brocade SNMP - - - - - - - - - - - - - - - - - 29
FA traps - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 29
MAPS traps - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 29
Updates to Chapter 4, MAPS-MIB Objects - - - - - - - - - - - - - - - - - - - - - - - - - - - 30
6 Fabric OS Documentation Updates53-1004135-07
About This Document
In this chapter•How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
•What’s new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
•Brocade Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
•Document feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
How this document is organized
This document contains updates to the Fabric OS 7.4.x product manuals: These updates include document fixes and changes covering new features. The following table lists the most recently released Fabric OS 7.4.x product manuals as of the date of this document. Refer to mybrocade.com for the posted versions of these documents.
TABLE 1 Documentation Supporting Fabric OS 7.4.x
Publication Title Fabric OS Release Page Number/Version ID Publication Date
Fabric OS Command Reference v7.4.0 Update on page 11 May 2015
Fabric OS Message Reference v7.4.0 Update on page 21 May 2015
v7.4.1 September 2015
Fabric OS Command Reference v7.4.x Update on page 17 April 2017
Fabric OS Message Reference v7.4.x Update on page 21 April 2017
Fabric OS MIB Reference v7.4.x Update on page 29 April 2017
Fabric OS Command Reference v7.4.2 Update on page 17 June 2017
Fabric OS Message Reference v7.4.2 Update on page 21 June 2017
Fabric OS Documentation Updates 753-1004135-07
What’s new in this document
NOTEFor Fabric OS 7.4.0 and later, most of the Fabric OS document updates are described only in the updated version of the document. These are available through and mybrocade.com.
The following documents are referenced in this publication; the listed document changes have been made since this document was last released. Refer to the individual chapters for descriptions of all changes made since the first version (-01) of a document was released. If a document has not been updated, it will not be listed in this publication. This section only provides an overview, refer to the specific book chapter for more details.
• For the Fabric OS Command Reference, the following changes are noted:
- Added entry for “ag” on page 19.
- Added entry for “portCfgNonDfe” on page 19.
• For the Fabric OS Message Reference, the following changes are noted:
- Five new messages have been added (BL-1080, C2-1034, C2-1035, C3-1041,C3-1042, FCPH-1009 ).
8 Fabric OS Documentation Updates53-1004135-07
Brocade Resources
To get up-to-the-minute information, go to http://my.brocade.com and register at no cost for a user ID and password.
For practical discussions about SAN design, implementation, and maintenance, you can obtain Building SANs with Brocade Fabric Switches through:
http://www.amazon.com
For additional Brocade documentation, visit the Brocade SAN Info Center and click the Resource Library location:
http://www.brocade.com
Release notes are available on the MyBrocade web site and are also bundled with the Fabric OS firmware.
Document feedback
Quality is our first concern at Brocade and we have made every effort to ensure the accuracy and completeness of this document. However, if you find an error or an omission, or you think that a topic needs further development, we want to hear from you. Forward your feedback to:
Provide the title and version number of the document and as much detail as possible about your comment, including the topic heading and page number and your suggestions for improvement.
Fabric OS Documentation Updates 953-1004135-07
10 Fabric OS Documentation Updates53-1004135-07
Fabric OS Documentation Updates53-1004135-07
Chapter
1
Fabric OS Command ReferenceIn this chapter•Documentation Updates for Fabric OS v7.4.0 . . . . . . . . . . . . . . . . . . . . . . . . 11
•Documentation Updates for Fabric OS v7.4.x . . . . . . . . . . . . . . . . . . . . . . . . 17
•Documentation Updates for Fabric OS v7.4.2 . . . . . . . . . . . . . . . . . . . . . . . . 18
Documentation Updates for Fabric OS v7.4.0The updates in this section are for the Fabric OS Command Reference, publication number 53-1003510-02, published 29 May 2015.
Updates to the "About This Document" chapterAdded the following note to “What is new in this document” section:
NOTEStandard operating system commands (for example, grep, more, or ping) are not documented, as they are fully documented elsewhere.
Updates to Chapter 2, Fabric OS Commands
agShow
Added the new operand "--all" and the new field "Type":
Synopsis agshow --all
Description TypeThe type of switch.
Operands --allDisplays detailed information regarding all Access Gateways that are registered with this fabric.
11
agShow1
Examples To display the Access Gateway information registered with the fabric:
switch:admin> agshow --name core_agName : core_agType : 162NodeName : 10:00:00:27:f8:f1:14:a0N-Port ID(s) : 0x0a6e00,0x0a3f00,0x071000Number of Ports : 64IP Address(es) : 10.20.113.165Firmware Version : v8.1.0N-Ports : 3F-Ports : 29Attached F-Port information : PortID Port WWN Switch F-port -------------------------------------------------- 0x0a6e01 10:00:00:05:1e:56:5f:29 91 0x0a6e02 10:00:00:05:1e:56:5e:00 91 0x0a6e03 10:00:8c:7c:ff:42:12:01 91 0x0a6e04 10:00:00:05:1e:56:5f:84 91 0x0a6e05 10:00:00:05:1e:56:5f:83 91 0x0a6e06 10:00:00:05:1e:56:63:59 91 0x0a6e07 10:00:00:05:1e:56:63:58 91 0x0a6e08 10:00:8c:7c:ff:42:81:00 91 0x0a6e09 10:00:00:00:00:00:00:01 91 0x0a6e0a 10:00:00:00:00:00:00:02 91 0x0a6e0b 10:00:00:00:00:00:00:03 91[...]Access Gateway F-Port Information : F-Port Number F-Port ID F-Port WWN --------------------------------------------------- 22 0x071001 20:16:00:27:f8:f1:14:a0 23 0x071002 20:17:00:27:f8:f1:14:a0 22 0x071003 20:16:00:27:f8:f1:14:a0 22 0x071004 20:16:00:27:f8:f1:14:a0 22 0x071005 20:16:00:27:f8:f1:14:a0 22 0x071006 20:16:00:27:f8:f1:14:a0 22 0x071007 20:16:00:27:f8:f1:14:a0
[...]
To display the detailed information of Access Gateways registered with the fabric:
switch:admin> agshow --allAG #1:Name : AG_300_154Type : 71NodeName : 10:00:00:05:1e:0b:50:99N-Port ID(s) : 0x0a1700,0x0a1e00,0x076e00Number of Ports : 24IP Address(es) : 10.20.113.154Firmware Version : v7.4.0aN-Ports : 3F-Ports : 0Attached F-Port information : PortID Port WWN Switch F-port --------------------------------------------------
AG #2:Name : AG_155Type : 66NodeName : 10:00:00:05:1e:61:dd:62
12 Fabric OS Documentation Updates53-1004135-07
configure 1
N-Port ID(s) : 0x0a0b00,0x0a5b00Number of Ports : 40IP Address(es) : 10.20.113.155Firmware Version : v7.4.0aN-Ports : 2F-Ports : 0Attached F-Port information : PortID Port WWN Switch F-port --------------------------------------------------
AG #3:Name : AG_Tom2_157Type : 118NodeName : 10:00:00:05:33:13:8a:baN-Port ID(s) : 0x0a0a00,0x0a0d00Number of Ports : 24IP Address(es) : 10.20.113.157Firmware Version : v8.0.1_bld49N-Ports : 2F-Ports : 8Attached F-Port information : PortID Port WWN Switch F-port -------------------------------------------- 0x0a0a01 10:00:8c:7c:ff:42:67:00 88 0x0a0a02 10:00:8c:7c:ff:42:67:01 88 0x0a0a03 10:00:8c:7c:ff:42:80:00 88 0x0a0a04 10:00:8c:7c:ff:42:70:01 88 0x0a0a05 10:00:8c:7c:ff:42:6d:00 88 0x0a0a06 10:00:8c:7c:ff:42:6d:01 88 0x0a0a07 10:00:8c:7c:ff:42:73:00 88 0x0a0a08 10:00:8c:7c:ff:42:73:01 88Access Gateway F-Port Information : F-Port Number F-Port ID F-Port WWN --------------------------------------------------- 12 0x0a0a01 20:0c:00:05:33:13:8a:ba 13 0x0a0a02 20:0d:00:05:33:13:8a:ba 14 0x0a0a03 20:0e:00:05:33:13:8a:ba 17 0x0a0a04 20:11:00:05:33:13:8a:ba 18 0x0a0a05 20:12:00:05:33:13:8a:ba 19 0x0a0a06 20:13:00:05:33:13:8a:ba 20 0x0a0a07 20:14:00:05:33:13:8a:ba
21 0x0a0a08 20:15:00:05:33:13:8a:ba
configure
Added the "F-Port Device Update Mode" option under Fabric Parameters:
Field Type Default Range __________________________________________________F-Port Device Update Mode Boolean on on/off
Added the following description for the F-Port Device Update Mode option:
F-Port Device Update Mode
Fabric OS Documentation Updates 1353-1004135-07
diagStatus1
When enabled, this feature provides the ability to update NS entries when the base devices perform logout. This option can only be changed when a switch is disabled. In Fabric OS prior to v7.3.0, the details of devices logged in with FLOGI (base devices) with AL_PA 0x40 and 0xC0 are not propagated to NS or FCP unless the devices are registered with NS. Since they cannot be probed, devices with these AL_PAs must initiate NS registration. If they do register with NS and then later logout, there can be multiple LUNs losing access during login time because the logged out base device entry is not removed from NS. Furthermore, the logged out base device cannot login to the fabric again. Enabling this update mode ensures NS and login database consistency.
The following commands are supported in Fabric OS 7.4.0 release.
diagStatus
Displays currently running diagnostic tests.
Synopsis diagstatus [slotnumber]
Description Use this command to display currently running diagnostic test names.
Operands The follow is optional:
slotnumberSpecifies the slot to display. If omitted, all blades in the system are assumed.
Examples To display currently running diagnostic tests:
switch:admin> diagstatusDiagnostic status for slot: 1.Diag executing "NONE"Diagnostic status for slot: 2.Diag executing "NONE"Diagnostic status for slot: 3.Diag executing "NONE"Diagnostic status for slot: 4.Diag executing "NONE"(output truncated)
See Also None
nsShow
The "NodeSymb" field has been enhanced to display user-friendly information about switch:
Examples To display local NS information:
switch:user> nsshow{ Type Pid COS PortName NodeName TTL(sec)N 010600; 3;25:00:00:27:f8:fd:1f:80;10:00:00:27:f8:fd:1f:80; na NodeSymb: [78] "Brocade-AG | C3_CORE_AG | 118 | 10.17.31.174 | v8.1.0" Fabric Port Name: 2f:00:00:27:f8:fd:1c:cf Permanent Port Name: 25:00:00:27:f8:fd:1f:80
14 Fabric OS Documentation Updates53-1004135-07
openSource 1
Port Index: 8 Share Area: No Device Shared in Other AD: No Redirect: No Partial: No LSAN: No Device link speed: 64GThe Local Name Server has 1 entry }
To display local name server information with the -r option.
switch:user> nsshow -r{ Type Pid COS PortName NodeName SCRN 010600; 3;25:00:00:27:f8:fd:1f:80;10:00:00:27:f8:fd:1f:80; \ 0x00000000 NodeSymb: [78] "Brocade-AG | C3_CORE_AG | 118 | 10.17.31.174 | v8.1.0" Fabric Port Name: 2f:00:00:27:f8:fd:1c:cf Permanent Port Name: 25:00:00:27:f8:fd:1f:80 Port Index: 8 Share Area: No Device Shared in Other AD: No Redirect: No Partial: No LSAN: No Device link speed: 64GThe Local Name Server has 1 entry }
To display local name server information with -r and -t options.
switch:user> nsshow -r -t{ Type Pid COS PortName NodeName SCRN 010600; 3;25:00:00:27:f8:fd:1f:80;10:00:00:27:f8:fd:1f:80; \ 0x00000000 NodeSymb: [78] "Brocade-AG | C3_CORE_AG | 118 | 10.17.31.174 | v8.1.0" Fabric Port Name: 2f:00:00:27:f8:fd:1c:cf Permanent Port Name: 25:00:00:27:f8:fd:1f:80 Device type: Physical Unknown(initiator/target) Port Index: 8 Share Area: No Device Shared in Other AD: No Redirect: No Partial: No LSAN: No Device link speed: 64GThe Local Name Server has 1 entry }
openSource
Displays open-source licenses.
Synopsis opensource
Description Displays listing of open source elements, licenses, and code samples used in Fabric OS. Refer to the Linux documentation for more information on how to use this command.
Fabric OS Documentation Updates 1553-1004135-07
sfpShow1
Operands None
Examples To display currently running diagnostic tests:
switch:admin> opensource In compliance with open source licensing requirements Brocade publishes open source information in the following location: http://www.brocade.com/support/oscd Also included in this file is a list of all open source licences associated with this release of the Fabric Operating System.
=======================================================License Text for apache 1.3.31Relative path to license text file: LICENSE=======================================================/* ==================================================================== * The Apache Software License, Version 1.1 * * Copyright (c) 2000-2002 The Apache Software Foundation. All rights * reserved. * * Redistribution and use in source and binary forms, with or without * modification, are permitted provided that the following conditions * are met: * * 1. Redistributions of source code must retain the above copyright * notice, this list of conditions and the following disclaimer. * * 2. Redistributions in binary form must reproduce the above copyright * notice, this list of conditions and the following disclaimer in * the documentation and/or other materials provided with the * distribution. * * 3. The end-user documentation included with the redistribution, * if any, must include the following acknowledgment: * "This product includes software developed by the * Apache Software Foundation (http://www.apache.org/)." * Alternately, this acknowledgment may appear in the software itself, * if and wherever such third-party acknowledgments normally appear. *Type <CR> or <SPACE BAR> to continue, <q> to stop(output truncated)
See Also None
sfpShow
Replaced "sfpshow 8/26" output with the following:
switch:admin> sfpshow 3/44QSFP No: 11 Channel No:0 Identifier: 13 QSFP+ Connector: 12 MPO Parallel Optic Transceiver: 0000000000000000 16_Gbps sw Short_dist Encoding: 5 64B66B Baud Rate: 140 (units 100 megabaud) Length 9u: 0 (units km)
16 Fabric OS Documentation Updates53-1004135-07
Documentation Updates for Fabric OS v7.4.x 1
Length 50u (OM4): 100 (units m) Length 62.5u: 0 (units m) Vendor Name: BROCADE Vendor OUI: 00:05:1e Vendor PN: 57-1000294-01 Vendor Rev: A Wavelength: 850 (units nm) Options: 00000fde Max Case Temp: 70 (C) Device Tech: 0x00 Serial No: HUA1140700000A1 Date Code: 140215 DD Type: 0x8 Enh Options: 0x0 Status/Ctrl: 0x0 Alarm flags[0,1]= 0x0, 0x0 Warn Flags[0,1] = 0x0, 0x0 Temperature: 32 Centigrade Current: 7.502 mAmps Voltage: 3272.6 mVolts RX Power: -1.8 dBm (659.9uW) State transitions: 1 Last poll time: 02-16-2016 PST Tue 22:18:49
Updates to Appendix A, Command AvailabilityAdded the following commands to TABLE 1:
Documentation Updates for Fabric OS v7.4.xThe updates in this section apply to all versions of the Fabric OS Command Reference, for Fabric OS 7.4.x.
portcmd
Corrected the time unit for the --wtool test time.
The correct time unit for the --wtool test time is minutes, not seconds.
portshow
Corrected the spelling of the man page example of the optional argument to show object hierarchy.
The correct spelling is:
switch:admin> portshow fciptunnel --hierarchy
TABLE 2 Admin Domain and Virtual Fabric restrictions for Fabric OS commands
Command name Admin Domain Context Switch type Remote Domain Execution
diagStatus SwitchMember CH N/A Disallowed
openSource Allowed CH N/A Allowed
Fabric OS Documentation Updates 1753-1004135-07
ficoncupset1
ficoncupset
Updated the Notes section to include the following:
High Integrity Fabric (HIF) mode must be enabled before FMSMODE is enabled.
portcfgshow
Updated the following operands description:
Fill Word (OnActive)
Displays the fill word setting that will take effect after the next time the port goes offline and comes back Possible values are 0(Idle-Idle), 1(arbff-arbff), 2(Idle-arbff), or 3(A-A then SW I-A).This parameter is set by the portcfgFillword command and is supported only on the Brocade Gen 4 platform switches.
Fill Word(Current)
Displays the currently effective fill word setting. Possible values are 0(Idle-Idle), 1(arbff-arbff), 2(Idle-arbff), or 3(A-A then SW I-A). This parameter is set by the portcfgFillword command and is supported only on the Brocade Gen 4 platform switches.
QOS Port Displays ON when Quality of Service (QoS) is enabled on the E_Port or EX_Port or F_Port when QoS is enabled in an FCR deployment scenario. Displays (..) or OFF when QoS is disabled. By default, QoS is enabled if sufficient buffers are available. Displays AE when QoS is configured as Auto Enabled. In the AE state, QoS is enabled based on the availability of buffers.
Removed the following:
FC Fastwrite Displays ON when FC FastWrite is enabled on the port or (..) or OFF when disabled. FastWrite is disabled by default. This value is set by the portCfg fastwrite FC Fastwrite is no longer supported as of Fabric OS v7.0.0.
Added the new operand "8GNon-DFE" and the description:
8G Non-DFE Displays ON (Static) if non-DFE is enabled on the port.
Displays OFF (Auto) if the feature is disabled (default).
portCfgFillword
Updated the Notes section:
Notes This command is only applicable to Brocade 8Gbps FC platforms and the FC8-64, FS8-18, and FX8-24 blades in DCX8510 directors.
Documentation Updates for Fabric OS v7.4.2The updates in this section are for the Fabric OS Command Reference, publication number 53-1003510-02, published 29 May 2015.
18 Fabric OS Documentation Updates53-1004135-07
ag 1
ag
Added the new operands "--failbackforce" and "--reliabilityshow".
Synopsis ag --failbackforce [N_Port | -pg pgid | -all]
ag --reliabilityshow N_Port
Added the following operands description:
--failbackforce[N_Port | -pg
pgid | -all]
Forces ports to login through the configured N_Port for the specified N_Port or for all N_Ports in the given port group if the ports are not already logged in. When used with the -all option, all F_Ports configured to all N_Ports, regardless of port group, are failed back to their respective N_Ports. Failback will not occur in a case where a failback is disabled on the N_Port or if the F_Ports are manually disabled by the user to avoid any override of other manual actions. The forced failback will not occur when the N_Port is in a port group that has Login Balancing enabled as it will automatically map F_Ports to the least utilized N_Ports.
--reliabilityshowN_Port
Displays the current reliable state of the N_Ports. Reliability is displayed as reliable (1) or unreliable (0). The N_Port parameter displays the reliability of the individual N_Port. If no parameter is specified the reliability of all N_Ports regardless of the port group is displayed.
portCfgNonDfe
Added the new operand "--force_disable".
Synopsis portcfgnondfe --force_disable [slot/] port [-port]
Description The --force_disable option is used to force disable non-DFE for the specified port (or range of ports) irrespective of the content of the Rx fillword.
Operands
--force_disable Force disables the non-DFE regardless of RX fillword.
Examples To force disable the non-DFE feature on a port range:
switch:admin> portcfgnondfe --force_disable 0-8
Fabric OS Documentation Updates 1953-1004135-07
portCfgNonDfe1
20 Fabric OS Documentation Updates53-1004135-07
Fabric OS Documentation Updates53-1004135-07
Chapter
2
Fabric OS Message ReferenceIn this chapter•Documentation updates for Fabric OS v7.4.0, v7.4.1, and v7.4.2 . . . . . . . . 21
Documentation updates for Fabric OS v7.4.0, v7.4.1, and v7.4.2 The updates in this section are for the following published documents:
• Fabric OS Message Reference supporting Fabric OS v7.4.0 (53-1003512-01), originally published in May 2015.
• Fabric OS Message Reference supporting Fabric OS v7.4.1 (53-1003943-01), originally published in September 2015.
Refer to mybrocade.com for the latest version of this document.
NOTEThe updates are arranged by the chapter names as they appear in the original document.
Updates to Chapter 1, Introduction to System MessagesTable 6 in the section “System Modules Description” has been updated to include the following Raslog modules along with description.
Table 6 System module descriptions.
Updates to Chapter 5, Fabric OS System Messages
Modified messages
• The command name "fosConfig" is not supported.
System module
Description
BCM BCM kernel module is a Linux driver which manages and indicates any problems associated with the Broadcom Ethernet switch for 10G/40G ports.
BLZ BLZ module messages indicate any problems associated with Fibre Channel over IP (FCIP) data path processing and configurations.
ESM Extension Services Module (ESM) provides management control and reporting for extension features such as FCIP and IPEX as well as their associated configurations.
L3SS L3SYS error messages indicate problems with the Layer 3 system manager that controls the IP routing table in hardware as well as Linux IP stack.
21
FV-30142
Use the command name "fosconfig" instead in the probable cause description of the following messages: FABR-1045, FCR-1068, FCR-1069, ISNS-1011. This error is resolved in Fabric OS 8.1.0 documents.
• The probable cause description of the FV-3014 Raslog message has been modified as follows.
FV-3014
Message All flows are reset for the feature(s) <feature_list>.
Message Type AUDIT
Class CFG
Severity INFO
Probable Cause Indicates all flows are reset for the specified features.
RecommendedAction
No action is required.
• The text of MS-1021 Raslog message has been modified as follows.
MS-1021
Message MS WARMBOOT failure(<failure reason><failure reason code>).
Message Type LOG
Severity ERROR
Probable Cause IIndicates that the Fabric OS state synchronization (FSS) warm recovery failed during the WARM INIT
phase of a reboot.
RecommendedAction
If the message persists, execute the supportFtp command (as needed) to set up automatic FTPtransfers; then execute the supportSave command and contact your switch service provider.
Deleted messages
The following message is not supported and therefore deleted from the “Fabric OS System Messages” chapter:
• SRM-1001
New messages
BL-1080
Message User port (<Port Number>) in slot:<Slot Number of blade that has the non qualified optic>(blade ID <Blade ID of blade that has the invalid SFP/QSFP module>) faulted due to
22 Fabric OS Documentation Updates53-1004135-07
C2-1034 2
detection of non qualified optic.
Message Type LOG
Severity ERROR
Probable Cause Indicates that a non qualified optic was detected and shut off to prevent unexpected behavior.
RecommendedAction
Replace with officially supported optic.
C2-1034
Message S<Slot>,P<User Port>(<Blade Port>): Both primary and secondary shared area ports have noIFID associated with shared IFID 0x<Shared IFID>.
Message Type LOG | FFDC
Severity WARNING
Probable Cause Indicates that routes to shared area ports may not be present.
RecommendedAction
Collect a supportsave immediately and deliver to the switch vendor.
C2-1035
Message Both primary and secondary shared area ports have no IFID associated with shared IFID0x<Shared IFID>.
Message Type LOG | FFDC
Severity WARNING
Probable Cause Indicates that routes to shared area ports may not be present.
RecommendedAction
Collect a supportsave immediately and deliver to the switch vendor.
C3-1041
Message S<Slot>,P<User Port>(<Blade Port>): Both primary and secondary shared area ports have no
Fabric OS Documentation Updates 2353-1004135-07
C3-10422
IFID associated with shared IFID 0x<Shared IFID>.
Message Type LOG | FFDC
Severity WARNING
Probable Cause Indicates that routes to shared area ports may not be present.
RecommendedAction
Collect a supportsave immediately and deliver to the switch vendor.
C3-1042
Message Both primary and secondary shared area ports have no IFID associated with shared IFID0x<Shared IFID>.
Message Type LOG | FFDC
Severity WARNING
Probable Cause Indicates that routes to shared area ports may not be present.
RecommendedAction
Collect a supportsave immediately and deliver to the switch vendor.
EM-1226
Message Slot <FRU slot number> is being powered off as it was detected as faulty during previous INIT.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the blade was detected as faulty in previous reboot and it is being intentionally powered-off.
RecommendedAction
Contact Switch Vendor or please remove the faulty blade and run slotpoweron with new blade
FCPH-1007
Message IU is freed. fc(<fc instance>), pt:<port>, frm:<frames_left>, s_id:0x<seq_id>,s_xid:0x<seq_xid>, s_state:0x<seq_state>, s_flags:0x<seq_flags>,s_lst_cnt:0x<seq_last_count>, s_cls:0x<seq_class>, x_pid:<x_x_xid>,
24 Fabric OS Documentation Updates53-1004135-07
FCPH-1008 2
x_seq_xid:<x_seq_xid>, x_seq_state:0x<x_seq_state>.
Message Type FFDC | LOG
Severity WARNING
Probable Cause Indicates that the sequence memory is already freed.
RecommendedAction
If message persists, please execute the supportSave command.
FCPH-1008
Message EXCH is NULL. fc(<fc instance>), pt:<port>, iu_refcnt:<iu_refcnt> sid:0x<sid> did:0x<did> two_abts:<two abts>.
Message Type FFDC | LOG
Severity WARNING
Probable Cause Indicates exchange is NULL.
RecommendedAction
If this message persists, please execute the supportSave command.
FCPH-1009
Message Sequence incomplete and dropped - fc=<fc>, seqid=<Sequence_ID>seq_frames=<Num_Frames_in_Sequence> seq_iu=0x<First_IU_In_Sequence>iu_seq_id=<IU_Sequence_ID> xid=0x<Exchange_ID> sid=0x<Source_ID> did=0x<Destination_ID>
Message Type LOG
Severity WARNING
Probable Cause A new sequence is received before a previous sequence is complete. This is likely caused by dropped frames.
RecommendedAction
Monitor links for dropped frames due to congestion (class 3 timeouts) and work with device vendor to alleviate the congestion.
Fabric OS Documentation Updates 2553-1004135-07
FV-10032
FV-1003
Message The sys_analytics_vtap flow is not enforced from <port_s> to <port_e> user ports as Encryption/Compression is enabled on one/many of them.
Message Type LOG
Severity WARNING
Probable Cause Indicates that RFM filters are not installed on ECB enabled asics.
RecommendedAction
No action is required.
HIL-1109
Message PS <Power Supply Number 1..4> SEEPROM corruption (fruhdr checksum mismatch) detected.
Message Type LOG
Severity ERROR
Probable Cause Indicates detection of PS fruhdr checksum mismatch.
RecommendedAction
No immediate action is required. The checksum mismatch is benign.
RAS-2010
Message Syslog daemon is started.
Message Type AUDIT
Class RAS
Severity INFO
Probable Cause Indicates that a syslog daemon is started.
RecommendedAction
No action is required.
RAS-2011
Message Syslog daemon is stopped.
Message Type AUDIT
26 Fabric OS Documentation Updates53-1004135-07
SULB-1060 2
Class RAS
Severity INFO
Probable Cause Indicates that a syslog daemon is stopped.
RecommendedAction
No action is required.
SULB-1060
Message Standby CP FOS version (v<major version>.<minor version>.<patch version><patch
id>) is below v6.4.0. CP FOS autosync is not permitted
Message Type AUDIT | LOG
Class FIRMWARE
Severity WARNING
Probable Cause Indicates that CP firmware auto synchronization is not permitted.
RecommendedAction
Manually run firmwaredownload on standby CP to bring it in sync with the same FOS version as on the Active CP.
SWCH-1031
Message Port <port number> recovery failed.
Message Type LOG
Severity WARNING
Probable Cause Indicates that warm recovery for specified port is failed upon HA.
RecommendedAction
No action is required.
TS-1011
Message <message>.
Message Type LOG | AUDIT | FFDC
Severity INFO
Probable Cause Hardware clock update fails
RecommendedAction
Please collect supportsave and report to vendor.
Fabric OS Documentation Updates 2753-1004135-07
TS-10112
28 Fabric OS Documentation Updates53-1004135-07
Fabric OS Documentation Updates53-1004135-07
Chapter
3
Fabric OS MIB ReferenceIn this chapter•Documentation updates for Fabric OS v7.4.0 and later . . . . . . . . . . . . . . . . 29
Documentation updates for Fabric OS v7.4.0 and laterThe updates in this chapter are for the Fabric OS MIB Reference supporting Fabric OS v7.4.0 (53-1003682-01), originally published in March 2015.
Refer to mybrocade.com for the latest version of this document.
NOTEThe updates are arranged by the chapter names as they appear in the original document.
Updates to Chapter 1, Understanding Brocade SNMPUnder the heading “Support for Virtual Fabric”, add the following note.
NOTEAn SNMPv3 must be used when a user wishes to manage a Virtual Fabric.
Under the heading “FA Traps”, remove the following unsupported trap.
FA traps• connUnitSensorStatusChange - This trap is generated by any sensor event.
Under the heading “Traps”, add the full form of “AM” abbreviation for mapsTrapAM mib as follows.
MAPS trapsConsider enabling the MAPS traps if you want to use SNMP to monitor Brocade switches.
• mapsTrapAM - Alerting and Monitoring traps to be sent for Monitoring and Alerting Policy Suite (MAPS) threshold events.
29
Documentation updates for Fabric OS v7.4.0 and later3
Updates to Chapter 4, MAPS-MIB ObjectsUnder the heading “MAPS Traps”, update the description of mapsTrapAM in table 29, as follows.
The OID represents the MAPS Alerting and Monitoring traps.
Object and OID Access Description
mapsTrapAM1.3.6.1.4.1.1588.3.1.4.0.1
mapsConfigRuleNamemapsConfigObjectGroupTypemapsConfigObjectKeyTypemapsConfigObjectKeyValuemapsConfigNumOfMSmapsConfigMsListmapsConfigSeverityLevelmapsConfigConditionmapsConfigActionswVfId
This Alerting and Monitoring trap is sent for MAPS threshold events.
30 Fabric OS Documentation Updates53-1004135-07