Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June...

30
53-1004135-07 30 June 2017 ® Fabric OS Documentation Updates Supporting Fabric OS 7.4.0 Supporting Fabric OS 7.4.1 Supporting Fabric OS 7.4.2

Transcript of Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June...

Page 1: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

53-1004135-0730 June 2017

®

Fabric OSDocumentation Updates

Supporting Fabric OS 7.4.0Supporting Fabric OS 7.4.1 Supporting Fabric OS 7.4.2

Page 2: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

©2017, Brocade Communications Systems, Inc. All Rights Reserved.

Brocade, the B-wing symbol, and MyBrocade are registered trademarks of Brocade Communications Systems, Inc., in the United States and in other countries. Other brands, product names, or service names mentioned of Brocade Communications Systems, Inc. are listed at http://www.brocade.com/en/legal/brocade-Legal-intellectual-property/brocade-legal-trademarks.html. Other marks may belong to third parties.

Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to this document at any time, without notice, and assumes no responsibility for its use. This informational document describes features that may not be currently available. Contact a Brocade sales office for information on feature and product availability. Export of technical data contained in this document may require an export license from the United States government.

The authors and Brocade Communications Systems, Inc. assume no liability or responsibility to any person or entity with respect to the accuracy of this document or any loss, cost, liability, or damages arising from the information contained herein or the computer programs that accompany it.

The product described by this document may contain open source software covered by the GNU General Public License or other open source license agreements. To find out which open source software is included in Brocade products, view the licensing terms applicable to the open source software, and obtain a copy of the programming source code, please visit http://www.brocade.com/support/oscd.

Brocade Communications Systems, Incorporated

Document History

Corporate and Latin American HeadquartersBrocade Communications Systems, Inc.130 Holger WaySan Jose, CA 95134 Tel: 1-408-333-8000 Fax: 1-408-333-8101 E-mail: [email protected]

Asia-Pacific HeadquartersBrocade Communications Systems China HK, Ltd.No. 1 Guanghua RoadChao Yang DistrictUnits 2718 and 2818Beijing 100020, ChinaTel: +8610 6588 8888Fax: +8610 6588 9999E-mail: [email protected]

European HeadquartersBrocade Communications Switzerland SàrlCentre SwissairTour B - 4ème étage29, Route de l'AéroportCase Postale 105CH-1215 Genève 15Switzerland Tel: +41 22 799 5640Fax: +41 22 799 5641E-mail: [email protected]

Asia-Pacific HeadquartersBrocade Communications Systems Co., Ltd. (Shenzhen WFOE)Citic PlazaNo. 233 Tian He Road NorthUnit 1308 – 13th FloorGuangzhou, ChinaTel: +8620 3891 2000Fax: +8620 3891 2111E-mail: [email protected]

Title Publication number Summary of changes Date

Fabric OS Documentation Updates 53-1004135-01 Updates for the following documents:• Fabric OS Command Reference• Fabric OS Message Reference• Fabric OS MIB Reference

January 2016

Fabric OS Documentation Updates 53-1004135-02 Updates for the following document:• Fabric OS Command Reference

February 2016

Fabric OS Documentation Updates 53-1004135-03 Updates for the following document:• Fabric OS Command Reference

February 2016

Fabric OS Documentation Updates 53-1004135-04 Updates for the following document:• Fabric OS Command Reference• Fabric OS Message Reference

October 2016

Fabric OS Documentation Updates 53-1004135-05 Updates for the following document:• Fabric OS Encryption

Administrator’s Guide

February 2017

Page 3: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

Fabric OS Documentation Updates 53-1004135-06 Updates for the following document:• Fabric OS Command Reference• Fabric OS Message Reference• Fabric OS MIB Reference

April 2017

Fabric OS Documentation Updates 53-1004135-07 Updates for the following document:• Fabric OS Command Reference• Fabric OS Message Reference

June 2017

Title Publication number Summary of changes Date

Fabric OS Documentation Updates 353-1004135-07

Page 4: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

4 Fabric OS Documentation Updates53-1004135-07

Page 5: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

Contents

About This Document

How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

What’s new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Brocade Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Document feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Chapter 1 Fabric OS Command Reference

Documentation Updates for Fabric OS v7.4.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Updates to the "About This Document" chapter- - - - - - - - - - - - - - - - - - - - - - - 11

Updates to Chapter 2, Fabric OS Commands- - - - - - - - - - - - - - - - - - - - - - - - - 11

agShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11configure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13diagStatus. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14nsShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14openSource. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15sfpShow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Updates to Appendix A, Command Availability - - - - - - - - - - - - - - - - - - - - - - - - 17

Documentation Updates for Fabric OS v7.4.x . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17portcmd. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17portshow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17ficoncupset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18portcfgshow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18portCfgFillword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Documentation Updates for Fabric OS v7.4.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18ag. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19portCfgNonDfe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Chapter 2 Fabric OS Message Reference

Documentation updates for Fabric OS v7.4.0, v7.4.1, and v7.4.2 . . . . . . . . . . . . 21Updates to Chapter 1, Introduction to System Messages - - - - - - - - - - - - - - - 21

Updates to Chapter 5, Fabric OS System Messages - - - - - - - - - - - - - - - - - - - 21

FV-3014. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22MS-1021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22BL-1080. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22C2-1034 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23C2-1035 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23C3-1041 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Fabric OS Documentation Updates 553-1004135-07

Page 6: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

C3-1042 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24EM-1226 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24FCPH-1007 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24FCPH-1008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25FCPH-1009 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25FV-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26HIL-1109 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26RAS-2010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26RAS-2011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26SULB-1060 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27SWCH-1031 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27TS-1011. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Chapter 3 Fabric OS MIB Reference

Documentation updates for Fabric OS v7.4.0 and later . . . . . . . . . . . . . . . . . . . . 29Updates to Chapter 1, Understanding Brocade SNMP - - - - - - - - - - - - - - - - - 29

FA traps - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 29

MAPS traps - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 29

Updates to Chapter 4, MAPS-MIB Objects - - - - - - - - - - - - - - - - - - - - - - - - - - - 30

6 Fabric OS Documentation Updates53-1004135-07

Page 7: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

About This Document

In this chapter•How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

•What’s new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

•Brocade Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

•Document feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

How this document is organized

This document contains updates to the Fabric OS 7.4.x product manuals: These updates include document fixes and changes covering new features. The following table lists the most recently released Fabric OS 7.4.x product manuals as of the date of this document. Refer to mybrocade.com for the posted versions of these documents.

TABLE 1 Documentation Supporting Fabric OS 7.4.x

Publication Title Fabric OS Release Page Number/Version ID Publication Date

Fabric OS Command Reference v7.4.0 Update on page 11 May 2015

Fabric OS Message Reference v7.4.0 Update on page 21 May 2015

v7.4.1 September 2015

Fabric OS Command Reference v7.4.x Update on page 17 April 2017

Fabric OS Message Reference v7.4.x Update on page 21 April 2017

Fabric OS MIB Reference v7.4.x Update on page 29 April 2017

Fabric OS Command Reference v7.4.2 Update on page 17 June 2017

Fabric OS Message Reference v7.4.2 Update on page 21 June 2017

Fabric OS Documentation Updates 753-1004135-07

Page 8: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

What’s new in this document

NOTEFor Fabric OS 7.4.0 and later, most of the Fabric OS document updates are described only in the updated version of the document. These are available through and mybrocade.com.

The following documents are referenced in this publication; the listed document changes have been made since this document was last released. Refer to the individual chapters for descriptions of all changes made since the first version (-01) of a document was released. If a document has not been updated, it will not be listed in this publication. This section only provides an overview, refer to the specific book chapter for more details.

• For the Fabric OS Command Reference, the following changes are noted:

- Added entry for “ag” on page 19.

- Added entry for “portCfgNonDfe” on page 19.

• For the Fabric OS Message Reference, the following changes are noted:

- Five new messages have been added (BL-1080, C2-1034, C2-1035, C3-1041,C3-1042, FCPH-1009 ).

8 Fabric OS Documentation Updates53-1004135-07

Page 9: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

Brocade Resources

To get up-to-the-minute information, go to http://my.brocade.com and register at no cost for a user ID and password.

For practical discussions about SAN design, implementation, and maintenance, you can obtain Building SANs with Brocade Fabric Switches through:

http://www.amazon.com

For additional Brocade documentation, visit the Brocade SAN Info Center and click the Resource Library location:

http://www.brocade.com

Release notes are available on the MyBrocade web site and are also bundled with the Fabric OS firmware.

Document feedback

Quality is our first concern at Brocade and we have made every effort to ensure the accuracy and completeness of this document. However, if you find an error or an omission, or you think that a topic needs further development, we want to hear from you. Forward your feedback to:

[email protected]

Provide the title and version number of the document and as much detail as possible about your comment, including the topic heading and page number and your suggestions for improvement.

Fabric OS Documentation Updates 953-1004135-07

Page 10: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

10 Fabric OS Documentation Updates53-1004135-07

Page 11: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

Fabric OS Documentation Updates53-1004135-07

Chapter

1

Fabric OS Command Reference

In this chapter•Documentation Updates for Fabric OS v7.4.0 . . . . . . . . . . . . . . . . . . . . . . . . 11

•Documentation Updates for Fabric OS v7.4.x . . . . . . . . . . . . . . . . . . . . . . . . 17

•Documentation Updates for Fabric OS v7.4.2 . . . . . . . . . . . . . . . . . . . . . . . . 18

Documentation Updates for Fabric OS v7.4.0The updates in this section are for the Fabric OS Command Reference, publication number 53-1003510-02, published 29 May 2015.

Updates to the "About This Document" chapterAdded the following note to “What is new in this document” section:

NOTEStandard operating system commands (for example, grep, more, or ping) are not documented, as they are fully documented elsewhere.

Updates to Chapter 2, Fabric OS Commands

agShow

Added the new operand "--all" and the new field "Type":

Synopsis agshow --all

Description TypeThe type of switch.

Operands --allDisplays detailed information regarding all Access Gateways that are registered with this fabric.

11

Page 12: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

agShow1

Examples To display the Access Gateway information registered with the fabric:

switch:admin> agshow --name core_agName : core_agType : 162NodeName : 10:00:00:27:f8:f1:14:a0N-Port ID(s) : 0x0a6e00,0x0a3f00,0x071000Number of Ports : 64IP Address(es) : 10.20.113.165Firmware Version : v8.1.0N-Ports : 3F-Ports : 29Attached F-Port information : PortID Port WWN Switch F-port -------------------------------------------------- 0x0a6e01 10:00:00:05:1e:56:5f:29 91 0x0a6e02 10:00:00:05:1e:56:5e:00 91 0x0a6e03 10:00:8c:7c:ff:42:12:01 91 0x0a6e04 10:00:00:05:1e:56:5f:84 91 0x0a6e05 10:00:00:05:1e:56:5f:83 91 0x0a6e06 10:00:00:05:1e:56:63:59 91 0x0a6e07 10:00:00:05:1e:56:63:58 91 0x0a6e08 10:00:8c:7c:ff:42:81:00 91 0x0a6e09 10:00:00:00:00:00:00:01 91 0x0a6e0a 10:00:00:00:00:00:00:02 91 0x0a6e0b 10:00:00:00:00:00:00:03 91[...]Access Gateway F-Port Information : F-Port Number F-Port ID F-Port WWN --------------------------------------------------- 22 0x071001 20:16:00:27:f8:f1:14:a0 23 0x071002 20:17:00:27:f8:f1:14:a0 22 0x071003 20:16:00:27:f8:f1:14:a0 22 0x071004 20:16:00:27:f8:f1:14:a0 22 0x071005 20:16:00:27:f8:f1:14:a0 22 0x071006 20:16:00:27:f8:f1:14:a0 22 0x071007 20:16:00:27:f8:f1:14:a0

[...]

To display the detailed information of Access Gateways registered with the fabric:

switch:admin> agshow --allAG #1:Name : AG_300_154Type : 71NodeName : 10:00:00:05:1e:0b:50:99N-Port ID(s) : 0x0a1700,0x0a1e00,0x076e00Number of Ports : 24IP Address(es) : 10.20.113.154Firmware Version : v7.4.0aN-Ports : 3F-Ports : 0Attached F-Port information : PortID Port WWN Switch F-port --------------------------------------------------

AG #2:Name : AG_155Type : 66NodeName : 10:00:00:05:1e:61:dd:62

12 Fabric OS Documentation Updates53-1004135-07

Page 13: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

configure 1

N-Port ID(s) : 0x0a0b00,0x0a5b00Number of Ports : 40IP Address(es) : 10.20.113.155Firmware Version : v7.4.0aN-Ports : 2F-Ports : 0Attached F-Port information : PortID Port WWN Switch F-port --------------------------------------------------

AG #3:Name : AG_Tom2_157Type : 118NodeName : 10:00:00:05:33:13:8a:baN-Port ID(s) : 0x0a0a00,0x0a0d00Number of Ports : 24IP Address(es) : 10.20.113.157Firmware Version : v8.0.1_bld49N-Ports : 2F-Ports : 8Attached F-Port information : PortID Port WWN Switch F-port -------------------------------------------- 0x0a0a01 10:00:8c:7c:ff:42:67:00 88 0x0a0a02 10:00:8c:7c:ff:42:67:01 88 0x0a0a03 10:00:8c:7c:ff:42:80:00 88 0x0a0a04 10:00:8c:7c:ff:42:70:01 88 0x0a0a05 10:00:8c:7c:ff:42:6d:00 88 0x0a0a06 10:00:8c:7c:ff:42:6d:01 88 0x0a0a07 10:00:8c:7c:ff:42:73:00 88 0x0a0a08 10:00:8c:7c:ff:42:73:01 88Access Gateway F-Port Information : F-Port Number F-Port ID F-Port WWN --------------------------------------------------- 12 0x0a0a01 20:0c:00:05:33:13:8a:ba 13 0x0a0a02 20:0d:00:05:33:13:8a:ba 14 0x0a0a03 20:0e:00:05:33:13:8a:ba 17 0x0a0a04 20:11:00:05:33:13:8a:ba 18 0x0a0a05 20:12:00:05:33:13:8a:ba 19 0x0a0a06 20:13:00:05:33:13:8a:ba 20 0x0a0a07 20:14:00:05:33:13:8a:ba

21 0x0a0a08 20:15:00:05:33:13:8a:ba

configure

Added the "F-Port Device Update Mode" option under Fabric Parameters:

Field Type Default Range __________________________________________________F-Port Device Update Mode Boolean on on/off

Added the following description for the F-Port Device Update Mode option:

F-Port Device Update Mode

Fabric OS Documentation Updates 1353-1004135-07

Page 14: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

diagStatus1

When enabled, this feature provides the ability to update NS entries when the base devices perform logout. This option can only be changed when a switch is disabled. In Fabric OS prior to v7.3.0, the details of devices logged in with FLOGI (base devices) with AL_PA 0x40 and 0xC0 are not propagated to NS or FCP unless the devices are registered with NS. Since they cannot be probed, devices with these AL_PAs must initiate NS registration. If they do register with NS and then later logout, there can be multiple LUNs losing access during login time because the logged out base device entry is not removed from NS. Furthermore, the logged out base device cannot login to the fabric again. Enabling this update mode ensures NS and login database consistency.

The following commands are supported in Fabric OS 7.4.0 release.

diagStatus

Displays currently running diagnostic tests.

Synopsis diagstatus [slotnumber]

Description Use this command to display currently running diagnostic test names.

Operands The follow is optional:

slotnumberSpecifies the slot to display. If omitted, all blades in the system are assumed.

Examples To display currently running diagnostic tests:

switch:admin> diagstatusDiagnostic status for slot: 1.Diag executing "NONE"Diagnostic status for slot: 2.Diag executing "NONE"Diagnostic status for slot: 3.Diag executing "NONE"Diagnostic status for slot: 4.Diag executing "NONE"(output truncated)

See Also None

nsShow

The "NodeSymb" field has been enhanced to display user-friendly information about switch:

Examples To display local NS information:

switch:user> nsshow{ Type Pid COS PortName NodeName TTL(sec)N 010600; 3;25:00:00:27:f8:fd:1f:80;10:00:00:27:f8:fd:1f:80; na NodeSymb: [78] "Brocade-AG | C3_CORE_AG | 118 | 10.17.31.174 | v8.1.0" Fabric Port Name: 2f:00:00:27:f8:fd:1c:cf Permanent Port Name: 25:00:00:27:f8:fd:1f:80

14 Fabric OS Documentation Updates53-1004135-07

Page 15: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

openSource 1

Port Index: 8 Share Area: No Device Shared in Other AD: No Redirect: No Partial: No LSAN: No Device link speed: 64GThe Local Name Server has 1 entry }

To display local name server information with the -r option.

switch:user> nsshow -r{ Type Pid COS PortName NodeName SCRN 010600; 3;25:00:00:27:f8:fd:1f:80;10:00:00:27:f8:fd:1f:80; \ 0x00000000 NodeSymb: [78] "Brocade-AG | C3_CORE_AG | 118 | 10.17.31.174 | v8.1.0" Fabric Port Name: 2f:00:00:27:f8:fd:1c:cf Permanent Port Name: 25:00:00:27:f8:fd:1f:80 Port Index: 8 Share Area: No Device Shared in Other AD: No Redirect: No Partial: No LSAN: No Device link speed: 64GThe Local Name Server has 1 entry }

To display local name server information with -r and -t options.

switch:user> nsshow -r -t{ Type Pid COS PortName NodeName SCRN 010600; 3;25:00:00:27:f8:fd:1f:80;10:00:00:27:f8:fd:1f:80; \ 0x00000000 NodeSymb: [78] "Brocade-AG | C3_CORE_AG | 118 | 10.17.31.174 | v8.1.0" Fabric Port Name: 2f:00:00:27:f8:fd:1c:cf Permanent Port Name: 25:00:00:27:f8:fd:1f:80 Device type: Physical Unknown(initiator/target) Port Index: 8 Share Area: No Device Shared in Other AD: No Redirect: No Partial: No LSAN: No Device link speed: 64GThe Local Name Server has 1 entry }

openSource

Displays open-source licenses.

Synopsis opensource

Description Displays listing of open source elements, licenses, and code samples used in Fabric OS. Refer to the Linux documentation for more information on how to use this command.

Fabric OS Documentation Updates 1553-1004135-07

Page 16: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

sfpShow1

Operands None

Examples To display currently running diagnostic tests:

switch:admin> opensource In compliance with open source licensing requirements Brocade publishes open source information in the following location: http://www.brocade.com/support/oscd Also included in this file is a list of all open source licences associated with this release of the Fabric Operating System.

=======================================================License Text for apache 1.3.31Relative path to license text file: LICENSE=======================================================/* ==================================================================== * The Apache Software License, Version 1.1 * * Copyright (c) 2000-2002 The Apache Software Foundation. All rights * reserved. * * Redistribution and use in source and binary forms, with or without * modification, are permitted provided that the following conditions * are met: * * 1. Redistributions of source code must retain the above copyright * notice, this list of conditions and the following disclaimer. * * 2. Redistributions in binary form must reproduce the above copyright * notice, this list of conditions and the following disclaimer in * the documentation and/or other materials provided with the * distribution. * * 3. The end-user documentation included with the redistribution, * if any, must include the following acknowledgment: * "This product includes software developed by the * Apache Software Foundation (http://www.apache.org/)." * Alternately, this acknowledgment may appear in the software itself, * if and wherever such third-party acknowledgments normally appear. *Type <CR> or <SPACE BAR> to continue, <q> to stop(output truncated)

See Also None

sfpShow

Replaced "sfpshow 8/26" output with the following:

switch:admin> sfpshow 3/44QSFP No: 11 Channel No:0 Identifier: 13 QSFP+ Connector: 12 MPO Parallel Optic Transceiver: 0000000000000000 16_Gbps sw Short_dist Encoding: 5 64B66B Baud Rate: 140 (units 100 megabaud) Length 9u: 0 (units km)

16 Fabric OS Documentation Updates53-1004135-07

Page 17: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

Documentation Updates for Fabric OS v7.4.x 1

Length 50u (OM4): 100 (units m) Length 62.5u: 0 (units m) Vendor Name: BROCADE Vendor OUI: 00:05:1e Vendor PN: 57-1000294-01 Vendor Rev: A Wavelength: 850 (units nm) Options: 00000fde Max Case Temp: 70 (C) Device Tech: 0x00 Serial No: HUA1140700000A1 Date Code: 140215 DD Type: 0x8 Enh Options: 0x0 Status/Ctrl: 0x0 Alarm flags[0,1]= 0x0, 0x0 Warn Flags[0,1] = 0x0, 0x0 Temperature: 32 Centigrade Current: 7.502 mAmps Voltage: 3272.6 mVolts RX Power: -1.8 dBm (659.9uW) State transitions: 1 Last poll time: 02-16-2016 PST Tue 22:18:49

Updates to Appendix A, Command AvailabilityAdded the following commands to TABLE 1:

Documentation Updates for Fabric OS v7.4.xThe updates in this section apply to all versions of the Fabric OS Command Reference, for Fabric OS 7.4.x.

portcmd

Corrected the time unit for the --wtool test time.

The correct time unit for the --wtool test time is minutes, not seconds.

portshow

Corrected the spelling of the man page example of the optional argument to show object hierarchy.

The correct spelling is:

switch:admin> portshow fciptunnel --hierarchy

TABLE 2 Admin Domain and Virtual Fabric restrictions for Fabric OS commands

Command name Admin Domain Context Switch type Remote Domain Execution

diagStatus SwitchMember CH N/A Disallowed

openSource Allowed CH N/A Allowed

Fabric OS Documentation Updates 1753-1004135-07

Page 18: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

ficoncupset1

ficoncupset

Updated the Notes section to include the following:

High Integrity Fabric (HIF) mode must be enabled before FMSMODE is enabled.

portcfgshow

Updated the following operands description:

Fill Word (OnActive)

Displays the fill word setting that will take effect after the next time the port goes offline and comes back Possible values are 0(Idle-Idle), 1(arbff-arbff), 2(Idle-arbff), or 3(A-A then SW I-A).This parameter is set by the portcfgFillword command and is supported only on the Brocade Gen 4 platform switches.

Fill Word(Current)

Displays the currently effective fill word setting. Possible values are 0(Idle-Idle), 1(arbff-arbff), 2(Idle-arbff), or 3(A-A then SW I-A). This parameter is set by the portcfgFillword command and is supported only on the Brocade Gen 4 platform switches.

QOS Port Displays ON when Quality of Service (QoS) is enabled on the E_Port or EX_Port or F_Port when QoS is enabled in an FCR deployment scenario. Displays (..) or OFF when QoS is disabled. By default, QoS is enabled if sufficient buffers are available. Displays AE when QoS is configured as Auto Enabled. In the AE state, QoS is enabled based on the availability of buffers.

Removed the following:

FC Fastwrite Displays ON when FC FastWrite is enabled on the port or (..) or OFF when disabled. FastWrite is disabled by default. This value is set by the portCfg fastwrite FC Fastwrite is no longer supported as of Fabric OS v7.0.0.

Added the new operand "8GNon-DFE" and the description:

8G Non-DFE Displays ON (Static) if non-DFE is enabled on the port.

Displays OFF (Auto) if the feature is disabled (default).

portCfgFillword

Updated the Notes section:

Notes This command is only applicable to Brocade 8Gbps FC platforms and the FC8-64, FS8-18, and FX8-24 blades in DCX8510 directors.

Documentation Updates for Fabric OS v7.4.2The updates in this section are for the Fabric OS Command Reference, publication number 53-1003510-02, published 29 May 2015.

18 Fabric OS Documentation Updates53-1004135-07

Page 19: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

ag 1

ag

Added the new operands "--failbackforce" and "--reliabilityshow".

Synopsis ag --failbackforce [N_Port | -pg pgid | -all]

ag --reliabilityshow N_Port

Added the following operands description:

--failbackforce[N_Port | -pg

pgid | -all]

Forces ports to login through the configured N_Port for the specified N_Port or for all N_Ports in the given port group if the ports are not already logged in. When used with the -all option, all F_Ports configured to all N_Ports, regardless of port group, are failed back to their respective N_Ports. Failback will not occur in a case where a failback is disabled on the N_Port or if the F_Ports are manually disabled by the user to avoid any override of other manual actions. The forced failback will not occur when the N_Port is in a port group that has Login Balancing enabled as it will automatically map F_Ports to the least utilized N_Ports.

--reliabilityshowN_Port

Displays the current reliable state of the N_Ports. Reliability is displayed as reliable (1) or unreliable (0). The N_Port parameter displays the reliability of the individual N_Port. If no parameter is specified the reliability of all N_Ports regardless of the port group is displayed.

portCfgNonDfe

Added the new operand "--force_disable".

Synopsis portcfgnondfe --force_disable [slot/] port [-port]

Description The --force_disable option is used to force disable non-DFE for the specified port (or range of ports) irrespective of the content of the Rx fillword.

Operands

--force_disable Force disables the non-DFE regardless of RX fillword.

Examples To force disable the non-DFE feature on a port range:

switch:admin> portcfgnondfe --force_disable 0-8

Fabric OS Documentation Updates 1953-1004135-07

Page 20: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

portCfgNonDfe1

20 Fabric OS Documentation Updates53-1004135-07

Page 21: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

Fabric OS Documentation Updates53-1004135-07

Chapter

2

Fabric OS Message Reference

In this chapter•Documentation updates for Fabric OS v7.4.0, v7.4.1, and v7.4.2 . . . . . . . . 21

Documentation updates for Fabric OS v7.4.0, v7.4.1, and v7.4.2 The updates in this section are for the following published documents:

• Fabric OS Message Reference supporting Fabric OS v7.4.0 (53-1003512-01), originally published in May 2015.

• Fabric OS Message Reference supporting Fabric OS v7.4.1 (53-1003943-01), originally published in September 2015.

Refer to mybrocade.com for the latest version of this document.

NOTEThe updates are arranged by the chapter names as they appear in the original document.

Updates to Chapter 1, Introduction to System MessagesTable 6 in the section “System Modules Description” has been updated to include the following Raslog modules along with description.

Table 6 System module descriptions.

Updates to Chapter 5, Fabric OS System Messages

Modified messages

• The command name "fosConfig" is not supported.

System module

Description

BCM BCM kernel module is a Linux driver which manages and indicates any problems associated with the Broadcom Ethernet switch for 10G/40G ports.

BLZ BLZ module messages indicate any problems associated with Fibre Channel over IP (FCIP) data path processing and configurations.

ESM Extension Services Module (ESM) provides management control and reporting for extension features such as FCIP and IPEX as well as their associated configurations.

L3SS L3SYS error messages indicate problems with the Layer 3 system manager that controls the IP routing table in hardware as well as Linux IP stack.

21

Page 22: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

FV-30142

Use the command name "fosconfig" instead in the probable cause description of the following messages: FABR-1045, FCR-1068, FCR-1069, ISNS-1011. This error is resolved in Fabric OS 8.1.0 documents.

• The probable cause description of the FV-3014 Raslog message has been modified as follows.

FV-3014

Message All flows are reset for the feature(s) <feature_list>.

Message Type AUDIT

Class CFG

Severity INFO

Probable Cause Indicates all flows are reset for the specified features.

RecommendedAction

No action is required.

• The text of MS-1021 Raslog message has been modified as follows.

MS-1021

Message MS WARMBOOT failure(<failure reason><failure reason code>).

Message Type LOG

Severity ERROR

Probable Cause IIndicates that the Fabric OS state synchronization (FSS) warm recovery failed during the WARM INIT

phase of a reboot.

RecommendedAction

If the message persists, execute the supportFtp command (as needed) to set up automatic FTPtransfers; then execute the supportSave command and contact your switch service provider.

Deleted messages

The following message is not supported and therefore deleted from the “Fabric OS System Messages” chapter:

• SRM-1001

New messages

BL-1080

Message User port (<Port Number>) in slot:<Slot Number of blade that has the non qualified optic>(blade ID <Blade ID of blade that has the invalid SFP/QSFP module>) faulted due to

22 Fabric OS Documentation Updates53-1004135-07

Page 23: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

C2-1034 2

detection of non qualified optic.

Message Type LOG

Severity ERROR

Probable Cause Indicates that a non qualified optic was detected and shut off to prevent unexpected behavior.

RecommendedAction

Replace with officially supported optic.

C2-1034

Message S<Slot>,P<User Port>(<Blade Port>): Both primary and secondary shared area ports have noIFID associated with shared IFID 0x<Shared IFID>.

Message Type LOG | FFDC

Severity WARNING

Probable Cause Indicates that routes to shared area ports may not be present.

RecommendedAction

Collect a supportsave immediately and deliver to the switch vendor.

C2-1035

Message Both primary and secondary shared area ports have no IFID associated with shared IFID0x<Shared IFID>.

Message Type LOG | FFDC

Severity WARNING

Probable Cause Indicates that routes to shared area ports may not be present.

RecommendedAction

Collect a supportsave immediately and deliver to the switch vendor.

C3-1041

Message S<Slot>,P<User Port>(<Blade Port>): Both primary and secondary shared area ports have no

Fabric OS Documentation Updates 2353-1004135-07

Page 24: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

C3-10422

IFID associated with shared IFID 0x<Shared IFID>.

Message Type LOG | FFDC

Severity WARNING

Probable Cause Indicates that routes to shared area ports may not be present.

RecommendedAction

Collect a supportsave immediately and deliver to the switch vendor.

C3-1042

Message Both primary and secondary shared area ports have no IFID associated with shared IFID0x<Shared IFID>.

Message Type LOG | FFDC

Severity WARNING

Probable Cause Indicates that routes to shared area ports may not be present.

RecommendedAction

Collect a supportsave immediately and deliver to the switch vendor.

EM-1226

Message Slot <FRU slot number> is being powered off as it was detected as faulty during previous INIT.

Message Type LOG

Severity ERROR

Probable Cause Indicates that the blade was detected as faulty in previous reboot and it is being intentionally powered-off.

RecommendedAction

Contact Switch Vendor or please remove the faulty blade and run slotpoweron with new blade

FCPH-1007

Message IU is freed. fc(<fc instance>), pt:<port>, frm:<frames_left>, s_id:0x<seq_id>,s_xid:0x<seq_xid>, s_state:0x<seq_state>, s_flags:0x<seq_flags>,s_lst_cnt:0x<seq_last_count>, s_cls:0x<seq_class>, x_pid:<x_x_xid>,

24 Fabric OS Documentation Updates53-1004135-07

Page 25: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

FCPH-1008 2

x_seq_xid:<x_seq_xid>, x_seq_state:0x<x_seq_state>.

Message Type FFDC | LOG

Severity WARNING

Probable Cause Indicates that the sequence memory is already freed.

RecommendedAction

If message persists, please execute the supportSave command.

FCPH-1008

Message EXCH is NULL. fc(<fc instance>), pt:<port>, iu_refcnt:<iu_refcnt> sid:0x<sid> did:0x<did> two_abts:<two abts>.

Message Type FFDC | LOG

Severity WARNING

Probable Cause Indicates exchange is NULL.

RecommendedAction

If this message persists, please execute the supportSave command.

FCPH-1009

Message Sequence incomplete and dropped - fc=<fc>, seqid=<Sequence_ID>seq_frames=<Num_Frames_in_Sequence> seq_iu=0x<First_IU_In_Sequence>iu_seq_id=<IU_Sequence_ID> xid=0x<Exchange_ID> sid=0x<Source_ID> did=0x<Destination_ID>

Message Type LOG

Severity WARNING

Probable Cause A new sequence is received before a previous sequence is complete. This is likely caused by dropped frames.

RecommendedAction

Monitor links for dropped frames due to congestion (class 3 timeouts) and work with device vendor to alleviate the congestion.

Fabric OS Documentation Updates 2553-1004135-07

Page 26: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

FV-10032

FV-1003

Message The sys_analytics_vtap flow is not enforced from <port_s> to <port_e> user ports as Encryption/Compression is enabled on one/many of them.

Message Type LOG

Severity WARNING

Probable Cause Indicates that RFM filters are not installed on ECB enabled asics.

RecommendedAction

No action is required.

HIL-1109

Message PS <Power Supply Number 1..4> SEEPROM corruption (fruhdr checksum mismatch) detected.

Message Type LOG

Severity ERROR

Probable Cause Indicates detection of PS fruhdr checksum mismatch.

RecommendedAction

No immediate action is required. The checksum mismatch is benign.

RAS-2010

Message Syslog daemon is started.

Message Type AUDIT

Class RAS

Severity INFO

Probable Cause Indicates that a syslog daemon is started.

RecommendedAction

No action is required.

RAS-2011

Message Syslog daemon is stopped.

Message Type AUDIT

26 Fabric OS Documentation Updates53-1004135-07

Page 27: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

SULB-1060 2

Class RAS

Severity INFO

Probable Cause Indicates that a syslog daemon is stopped.

RecommendedAction

No action is required.

SULB-1060

Message Standby CP FOS version (v<major version>.<minor version>.<patch version><patch

id>) is below v6.4.0. CP FOS autosync is not permitted

Message Type AUDIT | LOG

Class FIRMWARE

Severity WARNING

Probable Cause Indicates that CP firmware auto synchronization is not permitted.

RecommendedAction

Manually run firmwaredownload on standby CP to bring it in sync with the same FOS version as on the Active CP.

SWCH-1031

Message Port <port number> recovery failed.

Message Type LOG

Severity WARNING

Probable Cause Indicates that warm recovery for specified port is failed upon HA.

RecommendedAction

No action is required.

TS-1011

Message <message>.

Message Type LOG | AUDIT | FFDC

Severity INFO

Probable Cause Hardware clock update fails

RecommendedAction

Please collect supportsave and report to vendor.

Fabric OS Documentation Updates 2753-1004135-07

Page 28: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

TS-10112

28 Fabric OS Documentation Updates53-1004135-07

Page 29: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

Fabric OS Documentation Updates53-1004135-07

Chapter

3

Fabric OS MIB Reference

In this chapter•Documentation updates for Fabric OS v7.4.0 and later . . . . . . . . . . . . . . . . 29

Documentation updates for Fabric OS v7.4.0 and laterThe updates in this chapter are for the Fabric OS MIB Reference supporting Fabric OS v7.4.0 (53-1003682-01), originally published in March 2015.

Refer to mybrocade.com for the latest version of this document.

NOTEThe updates are arranged by the chapter names as they appear in the original document.

Updates to Chapter 1, Understanding Brocade SNMPUnder the heading “Support for Virtual Fabric”, add the following note.

NOTEAn SNMPv3 must be used when a user wishes to manage a Virtual Fabric.

Under the heading “FA Traps”, remove the following unsupported trap.

FA traps• connUnitSensorStatusChange - This trap is generated by any sensor event.

Under the heading “Traps”, add the full form of “AM” abbreviation for mapsTrapAM mib as follows.

MAPS trapsConsider enabling the MAPS traps if you want to use SNMP to monitor Brocade switches.

• mapsTrapAM - Alerting and Monitoring traps to be sent for Monitoring and Alerting Policy Suite (MAPS) threshold events.

29

Page 30: Fabric OS Documentation Updates, 7.4 · Fabric OS Message Reference v7.4.2 Update on page 21 June 2017. 8 Fabric OS Documentation Updates 53-1004135-07 What’s new in this document

Documentation updates for Fabric OS v7.4.0 and later3

Updates to Chapter 4, MAPS-MIB ObjectsUnder the heading “MAPS Traps”, update the description of mapsTrapAM in table 29, as follows.

The OID represents the MAPS Alerting and Monitoring traps.

Object and OID Access Description

mapsTrapAM1.3.6.1.4.1.1588.3.1.4.0.1

mapsConfigRuleNamemapsConfigObjectGroupTypemapsConfigObjectKeyTypemapsConfigObjectKeyValuemapsConfigNumOfMSmapsConfigMsListmapsConfigSeverityLevelmapsConfigConditionmapsConfigActionswVfId

This Alerting and Monitoring trap is sent for MAPS threshold events.

30 Fabric OS Documentation Updates53-1004135-07