F82C - Excelon Plus Modular System Oil removal...
Transcript of F82C - Excelon Plus Modular System Oil removal...
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2019 Norgren Ltd
6/19en us 8.105.155
Technical features
> Port size: 1/4” & 3/8” (ISO G/PTF)
> Excelon® Plus design allows in-line installation or modular installation with other Excelon® Plus products
> High efficiency oil and particle removal
> Double safety lock bowl
> Metal bowl with prismatic liquid level indicator lens
> Light weight Polycarbonate bowl
> Service indicator standard
> Air purity class in accordance with ISO 8573-1: Remaining oil
aerosol to class 1*
*Tested in accordance with the methods laid out in ISO 12500-1 using an inlet oil aerosol concentration of 4mg/m³
Medium:Compressed air only
Maximum operating pressure:Polycarbonate bowl: 145 psi (10 bar)Metal bowl: 246 psi (17 bar)
Remaining oil content:0.01 mg/m3 at +69°F (+21°C)
Particle removal:To 0.01 μm
Port size:G1/4, G3/8, 1/4 PTF, 3/8 PTF
Dry element flow:operating pressure 91 psi (6.3 bar) and a Δp: 7.25 psi (0.5 bar) dropfrom set. 1/4”= 32 scfm (15.1 dm3/s)
Automatic drain operatingconditions (float operated): Bowl pressure required to close drain: 5 psi (> 0,35 bar)Bowl pressure required to open drain: 2.9 psi (≤ 0,2 bar)Minimum air flow required to close drain: 2 scfm (1 dm3/s)
Drain:Manual or automatic
Ambient/Media temperature:Polycarbonate bowl:+14 ... +140ºF (-10 ... +60ºC)Metal bowl:-4 ... +149°F (-20 ... +65ºC)Air supply must be dry enoughto avoid ice formation attemperatures below +35°F (+2°C).
Note:Install an F82G filter with a 5 μmfilter element upstream of the F82C filter for maximum service life.
Materials:Body: Die cast aluminiumBody covers: ABSBowl: Transparent PC with PP guard or die cast zincLiquid level indicator lens(metal bowl): PAFilter element:Synthetic fiber & PE foamBowl ‘o’- ring: ChloropreneElastomers: NBR
F82C - Excelon® Plus Modular SystemOil removal filters
Technical data F82C
1/4 Auto Guarded polycarbonate 0.55 (0.25) F82C-2AD-AP0
3/8 Auto Guarded polycarbonate 0.55 (0.25) F82C-3AD-AP0
1/4 Auto Metal with level indicator 0.97 (0.44) F82C-2AD-AD0
3/8 Auto Metal with level indicator 0.97 (0.44) F82C-3AD-AD0
1/4 Manual Guarded polycarbonate 0.55 (0.25) F82C-2AD-QP0
3/8 Manual Guarded polycarbonate 0.55 (0.25) F82C-3AD-QP0
1/4 Manual Metal with level indicator 0.99 (0.45) F82C-2AD-QD0
3/8 Manual Metal with level indicator 0.97 (0.44) F82C-3AD-QD0
Symbol Port Size Drain Bowl Weight lb (kg) Model
F82C–H H D – H H 0Option selectorSubstitute
23
SubstituteAG
SubstitutePD
SubstituteQA
Port size1/4“3/8“
Thread formPTFISO G
BowlTransparent with guard Metal with liquid indicator
Drain Manual Auto drain
(PTF)
AIR FLOW
scfm
dm3/s0
10 20 4030 50 60
10 20
36 psi(2.5 bar)
58 psi(4.0 bar)
91 psi(6.3 bar)
116 psi(8.0 bar)
145 psi(10.0 bar)ba
r gps
ig
PR
ESSU
RE
DR
OP
10
8
6
4
2
00
0.2
0.4
0.6
Port size: 3/8”
Port size: 1/4”
AIR FLOW
scfm
dm3/s0
10 20 4030 50 60
10 20
36 psi(2.5 bar)
58 psi(4.0 bar)
91 psi(6.3 bar)
116 psi(8.0 bar)
145 psi(10.0 bar)ba
r gps
ig
PR
ESSU
RE
DR
OP
10
8
6
4
2
00
0.2
0.4
0.6
6/19en us 8.105.155
F82C - Excelon® Plus Modular SystemOil removal filters
Flow characteristics
Port size: 1/4”Oil Coalescing Filter
Dry Flow
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9217b) © 2019 Norgren Ltd
Warning: Cancer and reproductive harm — www.p65warnings.ca.gov.
Inlet Pressure psi (bar)
36 (2.5)
58 (4)
91 (6.3)
116 (8)
145 (10)
2.6
3.7
5.5
6.8
8.3
Flow-rate to maintain media velocity of
ISO12500-1 test on oil coalescing filter (L/sec)
6/19en us 8.105.155
F82C - Excelon® Plus Modular SystemOil removal filters
Maintenance/Service
6000-61KIT
Auto drain kit withmetal Nut - Imperial
820044-50KIT
Coalescing filter element
6000-60KIT
Auto drain kit withmetal Nut - Metric
820028-50KIT
*1) Flanged version. For other pressure ranges, please see data sheet 5.11.001*2) For other pressure ranges, please see data sheet 5.11.385
820028-53KIT 0523109000000000 0881300000000000
Accessories
820024-50KIT 820014-51KIT 820014-52KIT 820016-50KIT 820016-51KIT
0860810000000000
Wall mounting bracket Quikclamp® Quikclamp®
with bracket assembledPressure sensing block1/4 PTF
Pressure sensing blockG1/4
page 4 page 4 page 4 page 4 page 4
Full flow porting block Full flow porting block Pressure switch interface Pneumatic pressure switch Digital pressure switch3/8 PTF G3/8 block (18D pressure switch) 18D (0,5 ... 8 bar) *1) 51D(-1 ... 10 bar) *2)
page 4 page 4 page 5 page 5 page 6
820015-02KIT
Port Adaptors1/4 PTF
page 5
820015-03KIT
Port Adaptors3/8 PTF
page 5
820015-08KIT
Port AdaptorsG1/4
page 5
820015-09KIT
Port AdaptorsG3/8
page 5
Spare parts
820025-51KIT
820025-53KIT
820025-50KIT
820003-56KIT
820003-51KIT
Filter Bowl(Guarded Poly bowl with auto drain 6 mm PIF)
Filter Bowl(Guarded Poly bowl with auto drain, 1/4 PIF)
Filter Bowl(Guarded Poly bowl with manual drain)
Filter Bowl(Metal with S/Glass & auto drain, 1/4 PIF)
Filter Bowl(Metal with S/Glass & auto drain, 6 mm PIF)
820003-50KIT
Filter Bowl(Metal with S/Glass & manual drain)
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9217b) © 2019 Norgren Ltd
Warning: Cancer and reproductive harm — www.p65warnings.ca.gov.
F82C - Excelon® Plus Modular SystemOil removal filters
3
4
1
2
2.14
(54.
3)2.
04 (5
1.7)
0.98
(25.
0)
#0.9
8 (2
5.0)
6.19
(157
.2)
1/4
drai
n
6.27
(159
.4)
auto
drai
n
1.83 (46.5)
Dimensions
# Minimum clearance for bowl removal
Main ports 1/4”, 3/8” (ISO G/PTF)
Transparent bowl with guard
Metal bowl with liquid level indicator lens
Service indicator
n2
n3
n4
n1
6/19en us 8.105.155
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9217b) © 2019 Norgren Ltd
Warning: Cancer and reproductive harm — www.p65warnings.ca.gov.
Dimensions in inches (mm) Projection/Third angle
AccessoriesQuikclamp® with wall bracket Quikclamp®
2.3 (58.5)
1.7
(43.
0)
2.14
(54.
5)
4.07
(103
.3)
1.65
(42.
0)1.
53 (3
9.0)
1.5 (38.1)
.47 (12.1)
F82C - Excelon® Plus Modular SystemOil removal filters
6/19en us 8.105.155
1.85 (46.9) .47 (12.1)
1.7
(43.
1)
Full flow porting block
2X 1.44 (36.6)
.88 (22.3)
1.76 (44.6)
1.97 (50.125).98 (25.12)
1.66 (42.25)
.72 (18.3)
Pressure sensing block
1.5
(38.
0)
.75 (19.0)
1.12 (28.6)
1.42 (36.0)
Mounting bracket
2.1 (52.7)
.05 (1.52)
2.15
(54.
6)
1.1
(27.
1)
1.1
(27.
2)
1.46
(37.
0)
1.52
(38.
7)
2x .1 (2.68)
2x .24 (6.0)
2x .15 (3.7)
.21 (5.5)
.17 (4.3) 2x .83 (21.1)
.31 (8.0)
4x .39 (10.0)
4x .20(5.1)
2x .86 (22.0)
2x 1.0(26.2)
2x .12 (3.0)
1.94 (49.3)
.94 (23.8)
2x M4x0.7
8x FULL R
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9217b) © 2019 Norgren Ltd
Warning: Cancer and reproductive harm — www.p65warnings.ca.gov.
Dimensions in inches (mm) Projection/Third angle
F82C - Excelon® Plus Modular SystemOil removal filters
.19
(5)
1.18 (30)1.
18 (3
0)
1.77
(45)18
AC/
1.08 (27.5)
2.83 (72)
1.38 (35)
1.73 (44)
1.25 (32)
1.57
(40)
1.57 (40)
G1/4
Porting block for 18D pressure switch 18D Pressure switch
18D Porting block and 18D assembled Pipe adaptor
.90 (23.00)
.46 (11.90)
.54 (13.85)
.51 (13.10)
.33 (8.40)
1.03 (26.20)
.45 (11.50)
1.73 (44)
1.26 (32)
1.57 (40)
2.24 (57)
G1/4
1.57
(40)
6/19en us 8.105.155
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9217b) © 2019 Norgren Ltd
Warning: Cancer and reproductive harm — www.p65warnings.ca.gov.
Dimensions in inches (mm) Projection/Third angle
51D Pressure switch - digital
F82C - Excelon® Plus Modular SystemOil removal filters
6/19en us 8.105.155
WarningThese products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features/data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI Precision Engineering, Norgren Ltd.
Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure.System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products.
11.8
(300
.0)
1.22
(31.
0)
1
3
56
4
7
1.22 (31.0)
G1/
8
1.43 (36.50)
1.18
(30.
0)
2
Switch OUT 1, green LED Switch OUT 2, red LED Dustproof protector Connector M12 x 1 Inlet port Alternative inlet port G1/8 plugged Thread for mounting screw
1
2
3
4
5
6
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9217b) © 2019 Norgren Ltd
Warning: Cancer and reproductive harm — www.p65warnings.ca.gov.
Dimensions in inches (mm) Projection/Third angle