![Page 1: F All Experimenters' Mtg - 27 Jan 03 Week in Review: 01/20/03 -01/26/03 Ron Moore – FNAL Found obstacle in AP-1 line Replacing corroded Tevatron dipole.](https://reader034.fdocuments.in/reader034/viewer/2022051418/5697bffb1a28abf838cc13c4/html5/thumbnails/1.jpg)
All Experimenters' Mtg - 27 Jan 03
f Week in Review: 01/20/03 -01/26/03
Ron Moore – FNAL
• Found obstacle in AP-1 line• Replacing corroded Tevatron dipole stands
![Page 2: F All Experimenters' Mtg - 27 Jan 03 Week in Review: 01/20/03 -01/26/03 Ron Moore – FNAL Found obstacle in AP-1 line Replacing corroded Tevatron dipole.](https://reader034.fdocuments.in/reader034/viewer/2022051418/5697bffb1a28abf838cc13c4/html5/thumbnails/2.jpg)
All Experimenters' Mtg - 27 Jan 03
R. Moore - FNAL 2
f AP-1 Line Obstruction
• After 11/17 beam accident that caused vacuum leak at TOR105, saw higher than usual losses nearby and higher emittance growth of pbars in region during shots– Pbar emittances increased 7-8 (up from 3 ) between Acc and MI
• Opened AP-1 at SEM grid 103 on 12/3 – nothing seen, but SEM wire dangling at edge of aperture– Wire removed, but problem was unresolved
![Page 3: F All Experimenters' Mtg - 27 Jan 03 Week in Review: 01/20/03 -01/26/03 Ron Moore – FNAL Found obstacle in AP-1 line Replacing corroded Tevatron dipole.](https://reader034.fdocuments.in/reader034/viewer/2022051418/5697bffb1a28abf838cc13c4/html5/thumbnails/3.jpg)
0
2
4
6
8
10
12
14
0 50 100 150 200
Store number since April 2002
AP-1 vacuum problems11/16/02
Pbar emittance growth between the Accumulator and M.I.
Courtesy Jim Morgan
![Page 4: F All Experimenters' Mtg - 27 Jan 03 Week in Review: 01/20/03 -01/26/03 Ron Moore – FNAL Found obstacle in AP-1 line Replacing corroded Tevatron dipole.](https://reader034.fdocuments.in/reader034/viewer/2022051418/5697bffb1a28abf838cc13c4/html5/thumbnails/4.jpg)
![Page 5: F All Experimenters' Mtg - 27 Jan 03 Week in Review: 01/20/03 -01/26/03 Ron Moore – FNAL Found obstacle in AP-1 line Replacing corroded Tevatron dipole.](https://reader034.fdocuments.in/reader034/viewer/2022051418/5697bffb1a28abf838cc13c4/html5/thumbnails/5.jpg)
All Experimenters' Mtg - 27 Jan 03
R. Moore - FNAL 5
f AP-1 line schematic
obstacle here
protons for stacking
pbars from Acc to MI
![Page 6: F All Experimenters' Mtg - 27 Jan 03 Week in Review: 01/20/03 -01/26/03 Ron Moore – FNAL Found obstacle in AP-1 line Replacing corroded Tevatron dipole.](https://reader034.fdocuments.in/reader034/viewer/2022051418/5697bffb1a28abf838cc13c4/html5/thumbnails/6.jpg)
![Page 7: F All Experimenters' Mtg - 27 Jan 03 Week in Review: 01/20/03 -01/26/03 Ron Moore – FNAL Found obstacle in AP-1 line Replacing corroded Tevatron dipole.](https://reader034.fdocuments.in/reader034/viewer/2022051418/5697bffb1a28abf838cc13c4/html5/thumbnails/7.jpg)
Plastic beampipe cap removed from AP-1 line on 1/21
Protons came out of page; pbars went into page
![Page 8: F All Experimenters' Mtg - 27 Jan 03 Week in Review: 01/20/03 -01/26/03 Ron Moore – FNAL Found obstacle in AP-1 line Replacing corroded Tevatron dipole.](https://reader034.fdocuments.in/reader034/viewer/2022051418/5697bffb1a28abf838cc13c4/html5/thumbnails/8.jpg)
All Experimenters' Mtg - 27 Jan 03
R. Moore - FNAL 8
f Plastic Cap in AP-1
• Thought to have been there many years…– Hard to notice once hole was formed
• Red cap moved during vacuum incident in Nov.– Beam no longer through hole problem appears
• After removal, expect reduced pbar emittance growth between Accumulator and Main Injector
– Perhaps slightly smaller pbar emittances in Tev, too
– No earth-shattering improvements expected
![Page 9: F All Experimenters' Mtg - 27 Jan 03 Week in Review: 01/20/03 -01/26/03 Ron Moore – FNAL Found obstacle in AP-1 line Replacing corroded Tevatron dipole.](https://reader034.fdocuments.in/reader034/viewer/2022051418/5697bffb1a28abf838cc13c4/html5/thumbnails/9.jpg)
All Experimenters' Mtg - 27 Jan 03
R. Moore - FNAL 9
f Tevatron Magnet Stand Replacements
• Replacing stands for dipoles A16-3, A21-2, A21-3, A21-4– Stands appear very corroded – safety issue
• “Quick and dirty” mechanical measurements indicate significant dipole rolls; to be confirmed with optical survey– These rolls make the dipole correctors run harder, but not a big
problem currently
– At least one quad (not low-) rolled significantly?
• Will just replace stands now; fix alignment later
• Catalog all magnet stands, roll measurements now– address stand replacement, alignment later
![Page 10: F All Experimenters' Mtg - 27 Jan 03 Week in Review: 01/20/03 -01/26/03 Ron Moore – FNAL Found obstacle in AP-1 line Replacing corroded Tevatron dipole.](https://reader034.fdocuments.in/reader034/viewer/2022051418/5697bffb1a28abf838cc13c4/html5/thumbnails/10.jpg)
Tev A16-3 Dipole Photos
courtesy Ray Stefanski
![Page 11: F All Experimenters' Mtg - 27 Jan 03 Week in Review: 01/20/03 -01/26/03 Ron Moore – FNAL Found obstacle in AP-1 line Replacing corroded Tevatron dipole.](https://reader034.fdocuments.in/reader034/viewer/2022051418/5697bffb1a28abf838cc13c4/html5/thumbnails/11.jpg)
courtesy Todd Johnson
Tev A16-3 Upstream Stand
![Page 12: F All Experimenters' Mtg - 27 Jan 03 Week in Review: 01/20/03 -01/26/03 Ron Moore – FNAL Found obstacle in AP-1 line Replacing corroded Tevatron dipole.](https://reader034.fdocuments.in/reader034/viewer/2022051418/5697bffb1a28abf838cc13c4/html5/thumbnails/12.jpg)
All Experimenters' Mtg - 27 Jan 03
R. Moore - FNAL 12
f Summary
• Found and removed red plastic pipe cap in AP-1– Been there for a long time
– Source of proton losses during stacking, pbar emittance growth during shots
• Replacing stands of 4 Tevatron dipoles– Stands very corroded, posed a safety hazard
– Catalog all other magnet stands for future work