F-300 A & B User Guide

6
USER GUIDE F-300 Series Luxury Ozone Steamer With Herbs & Essential Oil Facility

description

F-300A/B Series steamer. User Guide.

Transcript of F-300 A & B User Guide

Page 1: F-300 A & B User Guide

USER GUIDE

F-300 Series

Luxury Ozone Steamer With Herbs & Essential Oil Facility

Page 2: F-300 A & B User Guide

F-300 SERIES FACIAL STEAMER . Function 1. To soften the skin & necrotic cells prior to cleansing in any subsequent treatments. 2. Opening up the skin pore’s for deep cleansing & drawing debris to the surface. 3. Steam vapour- penetrates deep into the pores and aids the breakdown of grease, black-heads,

make-up remnants as well as daily dirt and atmospheric pollution. 4. Steam vapour helps the skin to effectively release natural toxins. 5. Steam vapour helps to soften wrinkles prior to treatment. 6. Increase blood circulation, moisten the skin, improves metabolism and skin renewal. 7. Helps to treat acne, port wine stains, brighten and nourish the skin when used with herbs.

. Features This steamer has a metal casing; a double sheeted insulated base, stainless steel base, stainless steel water container and a copper vapour pipe. This makes for a compact and durable unit with a pleasant design. Its special stainless steel base provides enhanced stability and safety when the unit is hot. The unit’s components will not rust and therefore, no foreign matter can enter the water or steam unintentionally, which helps to avoid injury to the skin. The Steam nozzle is fully adjustable, and independently moveable of steamer arm. The steamer is equipped with a programmable timer for treatment duration. Has an automatic water level detector, which alarms if over filled or runs low of water, helping to prevent water spraying if the water level in over filled. The unit will automatically cut-out to prevent damage by ‘overheating’ should the unit be left unattended or misused by a user. Assembly Firstly remove the steamer from its transportation packaging, including the cellophane hygiene bags. Take the Glass water vessel from its packaging and ensure the rubber water seal is fitted to the rim of the jar. It is advisable to wash the new water vessel thoroughly before its first use, with clean water only. Next mount the water vessel into its housing point around the heater element ensuring a snug fit before tightening the retaining adjuster from below. Then mount the steamer to the trolley mounting point by aligning the bayonet fitting into the receiving hole of the trolley. Once this has been done, take the power supply lead and insert into the indicated socket on the rear of the steamer. Then plug the power cord into the mains and switch on.

Application . Using the microcomputer herbal facial steamer F-300A

1. Remove the herb pot & filler cap and pour the distilled water into the water container.

2. The water level should be between the max and min limit displayed side of the jar.

3. For using herbal treatments, remove the herb pot from the filler housing and place a small amount of herbs in the metal dish in the bottom of the herb pot. Then replace the herb pot and the filler cap. Special care should be taken to ensure nothing (any herbs) gets into the water supply as ‘any contaminate’ in the water will cause splitting and may result in injury.

4. Switch on the “POWER” button. --- Timer window shows a preset “15” min (you may adjust as required). --- The energy output shows “ZERO”.

--- The machine automatically detects the water level, and will not start if the water level is incorrect (it must be between the minimum and the maximum level marks). If the water level is within the safe limits, the machine will be able to be started. If it is wrong, an alarm sounds immediately and no functions will work until the correct water level is attained.

Page 3: F-300 A & B User Guide

5. Adjust steam power level by pressing “ + ” or “ - ” keys under the “ENERGY” setting will take the

steam output from “0 to 5”, of which “5” is the highest output. We suggest initially set the out to before the vapor sprays out of the pipe ,we suggest to choose “5” firstly, then adjust accordingly to the clients requirements

6. Time setting Pressing the “+”or “-” keys under “TIMER” to set time whose range is from “0-99”minutes. Default time is “15”minutes.

Switch on the “OZONE” button --- The green lamp turns on. --- Ozone light operates. --- There is an ozone smell in the vapor along with a distinct increase in atomization.

. Notes During operation, the water level will drop to the minimum limit, once reached, the machine will automatically turn off the heater element and lock (prevent use) all the keys except the ‘VAPOR’ button and is also accompanied by a constant buzzing alarm, which will continue until water is added to the normal level. Then repress the ‘VAPOR’ button to proceed with the re-starting of the steamer operation. After the preset working time is reached, the machine will switch off the “steam” automatically, and the steamer unit will buzz 5 times to indicate the chosen treatment time is finished. The preset time returns to default setting of 15 minutes. The machine then goes into stand-by mode and will not start until the cycle is repeated.

. Method 1. Remove the filler cap and herb pot; pour distilled water into the water container. The water level

should be filled between the “MAX”& “MIN” level displayed on the jar. To use herbs for treatment, remove the filler cap and take out the herb ‘cage & jar’, place a small amount of herbs into the metal tray in the cage, then replace the herb cage and filler cap. Special care should be taken to ensure nothing (any herbs) gets into the water supply as ‘any contaminate’ in the water will cause splitting and may result in injury.

2. Plug in and switch on mains supply 3. Turn the “vapour” timer dial clockwise to the desired treatment time

--- “vapour light” turns on. --- The heater starts to work. --- In about 6 minutes, steam vapor will come out from the arm nozzle.

4. Turn on the “ozone” switch (if desired) ---“ozone light” turns on. --- ozone light illuminates and starts working. --- You will notice an obvious ozone smell and an increase vapor atomization. During the working process, water in the cup will drop as the vapor sprays out constantly. When the water level reaches the low limit, please switch off the “VAPOR” button firstly, then switch off the power supply. Then, remove the filler cap & herb cage after the vapor stops. Refill with distilled water, switch on and return the timer to the desired time setting to resume operation. After the preset working time is reached, the machine will switch off the “steam” automatically and the unit will ‘ping’ from the timer bell to indicate the chosen treatment time has been reached. The preset time returns to default time of 0 minutes, and the machine then goes into stand-by mode and will not start until the cycle is repeated.

Page 4: F-300 A & B User Guide

.Treatment suggestions

CAUTION (during use)

1. Should height adjustment be required, you should tightly hold the stand pipe of the unit with one hand, then twist the tightening nut with another hand. Ensure the steamer is switched off during any adjustments, and is not pointing you or anyone else, so as to prevent injury.

2. The water vessel protector is used to prevent scalding by accidental touching the hot jar while

working. Always ensure the protector is fitted and in place before use. 3. When installing/fitting the water container, do not fasten the container securing support too tightly,

over tightening may damage the rubber jar ‘seal’ or shorten its lifespan. Over tightening may cause cracking of the glass water jar, and possible damage to the heater element.

4. The water level should be filled between the “MAX” & “MIN” level displayed on the side of the

water vessel during use. Incorrect levels may result in injury. 5. When adding water via the filler cap, always unplug the unit from the mains supply. Care should

be taken to avoid spillage and prevent leakage into the steamer housing and possible electrical shorting of the device.

6. If steam or water leakage is visible from the main housing during use. Switch off the “POWER”

button immediately, and disconnect from the mains power supply. Then remove the water container and check to ensure rubber seal is seated properly, then reinstall it Also check the main filler cap housing to ensure the seal is correctly fitted. If nothing is improved, please consult the sales agent.

7. When operating the steamer, the nozzle must not be aimed at client’s face until the vapor has

begun to spray out thinly and evenly, keeping a minimum distance of 40 cm from the face, the vapour should be sprayed between the client’s jaw and neck area, to the top of the face/hairline.

8. Since the ozone (when used) kills skin bacteria, it is not recommended for use over a prolonged

time, the usage times should be according to the client skin types (see below).

Skin types (recommendation) Distance Time

Greasy skin, poor blood circulation 35-40 cm Approx 15 min

Normal skin 35-40 cm “ 10 min

Sensitive skin, dry skin 40-45cm “ 5 min

Capillary vessel expansion, UV inflammation 40cm “ 5 min

Page 5: F-300 A & B User Guide

9. During continuous use, when water level falls below the low limit the following will occur:-

F-300A the machine will automatically turn off the heater element, at freeze the function of all the buttons keys, except the “VAPOR” button. This will be accompanied with a constant buzzing alarm, which will not stop until the water is added to the normal level. Then repress the ‘VAPOR’ key to proceed with operation. NEVER attempt to use the steamer with no water in the vessel, as damage may occur to the unit. F-300B the machine will automatically turn off the heater element by cutting off the power supply. Unless the timer unit has completed its cycle, add some water to continue operation. The machine will automatically resume steaming in approximately 1-3 minutes after adding water. NEVER attempt to use the steamer with no water in the vessel, as damage may occur to the unit.

10. The steamer/machine should only be used with an earth grounded mains supply.

WARNING Do not use any substance other than distilled water in your steamer unit water vessel, doing so will change the way the boiling process occurs and any ‘contamination’ will cause the steamer unit to spit or spray scalding water. Due care should be taken when using essential oils or herbs, so as not to contaminate the water used for steaming, as injury’s may occur due to accidental or negligent contamination during use. 1. NEVER point the vapour jet directly down onto the client’s face, as scalding may occur. 2. NEVER use the steamer unit in humid or unvented environments, such wet rooms or bathrooms etc. To

prevent damage to the electrical components of your unit. 3. NEVER use the steamer outside, exposure to the elements will cause damage. 4. NEVER bridge the safety cut-out probes beneath the steamer housing, as this will damage the heater

element and steamer circuitry (For F-300A). 5. NEVER attempt to open the steamer casing/housing yourself. As it contains no user serviceable

components. Always consult a qualified technician, or for further information contact your sales agent for advice on returns and repairs.

MAINTENANCE It is advisable to clean your steamer at least once a week, preferably to also include descaling of the water heater element. Once the steamer unit is cold the water vessel should be removed and filled with the appropriate descaling /water solution and left to stand overnight. Then remove the water vessel and rinse with clean water to expel any descaling agent residue. Then refill with water and run the steamer through a minimum of one run cycle, to remove any remaining residue from the steamer unit. Then remove the water vessel and rinse as before. Refill with water and you are then ready for use. Failure to remove all descaling residue may result in ‘spitting’ of the steamer. If this occurs, simply repeat the rinse and refill proceedure until the issue is resolved. Although the steamer unit has an automatic low level cut out system. It is advisable to regularly check the water level during operation. By pre-empting the activation of the safety cut out, you will extend both the time between cleaning, and also the longevity of the steamers heater element. Failure of the heater element due to incorrect operation or by lack of cleaning will invalidate your product warranty.

Page 6: F-300 A & B User Guide

Warranty Procedure

1 - The warranty on all Cosmetronic equipment is 12 months from the date of invoice and covers the products against defects in materials and workmanship or component defect (Unless superseded by an extended warranty agreement). This warranty is non transferable and applies to the original purchaser only. 2 - No product repairs or component replacement will take place unless all/any amounts owed to Cosmetronic for the said goods have been paid for in full, prior to any repairs. 3 - All extended warranty policies must be paid in full prior to dispatch of goods and will extend the above cover (No 1) by a further 2 or 4 years, to a maximum of 5 years including the first free year. 4 - Before returning any product to Cosmetronic UK Ltd for repair or replacement you must first: - - Endeavour to establish cause of product fault (e.g.. check fuses etc.). - Notify Cosmetronic of any fault development within 24 hrs of its occurrence. - Contact a member of our technical service dept (95% of faults can be rectified over the telephone). - Obtain an RMA (return material authorisation) from a member of Cosmetronic. - Package the goods to include all parts or accessories received with that item. - Any item received incomplete for repair will be made complete and all relevant parts charges added to repair. - Pack the goods to be returned in sufficient packaging as to prevent any damage occurring in transit, as Cosmetronic will not be held liable for damage to products due to insufficient packaging. - Clearly address the returned goods with our full postal address and RMA code. 5 - All goods returned to Cosmetronic without the correct RMA authorisation will be refused. 6 - No goods will automatically be replaced, when the faulty item can be repaired within a reasonable time span (except items deemed unserviceable on arrival). Goods will be replaced at the discretion of Cosmetronic when it is deemed that all/any goods are beyond economic repair. Items of loan equipment may be given at the discretion of the management and subject to delivery/collection charges, together with a refundable deposit. 7 - Cosmetronic will not be held liable for any momentary lack of stock, or technical resource, or any other circumstance beyond its control that may delay any component replacement or repair. Cosmetronic will not be held liable for any special, incidental, consequential damages resulting from a breach of warranty, or under any other legal theory, including but not limited to loss of profit or good will, downtime, damage to or any products, treatments used in conjunction with its products. Purchase implies your acceptance of Cosmetronic terms & conditions. 8 - When our service department cannot determine any fault or malfunction with the goods returned, you may

be liable for any administration and testing costs. 8a- When goods returned are not in a merchantable (dirty or unhygienic) condition, they will be made to

merchantable quality again, and cleaning costs will be charged where necessary. 9 - All goods returned will be at the owner’s risk. Cosmetronic will not be held liable for any damage or loss to

goods whilst in transit. 10 - Carriage costs are at the owners expense for both collection & return freight costs. All goods will be

carried via Cosmetronic nominated couriers unless specified. Any goods in transit insurance required must be requested prior to collection/dispatch.

11 - No repaired goods will be released until any costs relevant to that repair (unless under warranty) have been

settled in full, this will include all carriage/freight costs. 12 - Call out/on-site repairs will be carried out as soon as is physically possible and charged at a cost of £ POA.

The charge is based on the original delivery address of the product when purchased. This charge is payable in full, prior to any on site attendance. This charge will not include travel expenses (fuel, parking, toll charges etc.) but, will include labour and the parts replacement of electrical or motorised mechanical components, to include electrical motors, foot control boxes, system control boxes but does not include optional extras such as Vibro or Thermo heat functions. The call out repair charge will not cover items deemed as natural “wear & tear” such as upholstery etc. The call out charge will not cover damage by accident, misuse, or misapplication, or if the product has been modified without permission. Any serial numbers removed or displaced will also result in warranty invalidation. Proof of purchase will be required before any repairs carried out.

13 - Warranty call out, or on-site repairs, will be charged as per the prevailing rate (POA), terms and conditions,

but will be refunded once established that any fault is covered under and within the warranty period and criteria.