External fixator

65
1

description

external fixator

Transcript of External fixator

Page 1: External fixator

1

Page 2: External fixator

2

“External Fixator is a device uses for stabilization and immobilization of long bone open fractures.”

Page 3: External fixator

3

History

Earliest recognizable External fixations by Malgaigne 1840 pin for tibial fractures, griffe for patella

Page 4: External fixator

4

Keetley 1893, Ollier,

Roux

History

Page 5: External fixator

5

Parkhill 1894 Threaded pins and clamp

History

Page 6: External fixator

6

Lambotte 1902, self tapping threaded pins, rod, adjustable clamps

History

Page 7: External fixator

7

In 1917. Humphry is the 1st man who uses threaded pins, but he uses only one pin above fracture and one below the fracture site.

In 1948, Charnley popularized his compression device to facilitate arthrodesis of joints.

History

Page 8: External fixator

8

In 1966 and 1974,Anderson et al. uses transfixing pins incorporated into a plaster cast for management of large series of tibial shaft fractures .

From 1968 to 1970 Vidal and Vidal et al. modified original Hoffmann device from a single half –pin unit to a quadrilateral bicortical frame , greatly increasing rigidity.

History

Page 9: External fixator

9

Page 10: External fixator

10

Type -1 Unilateral Uniplanar Type -2 Uniplanar Bilateral. Type -3

◦ Classical Bilateral Biplanar.◦ Delta Unilateral Biplanar

According to Planes:◦ Planner: Hoffman’s, orthofix etc.◦ Circular: Ilizarov

Types

Page 11: External fixator

11

Page 12: External fixator

12

Page 13: External fixator

For periarticuler fracture Thin wire and ring near joint Schanz pin in shaft

13

Page 14: External fixator

14

Intrinsic stability of frame (S)

EX I

S = ----------- L

E=modulus of elasticity =constantI= moment of intertia= constantL= distance of frame from axis.

Page 15: External fixator

15

Thus Stability is inversely proportional to the distance of the assembly from the bone

(closer the frame to bone -more stable assembly)

Biomechanics

Page 16: External fixator

16

To increase stability of bone –pin interface

1. Adequate no. of pins in each fragments ( 2 for most bone & 3 for femur)

2. Increase pin pitch (3.5mm)

3. Increase size of pin

Page 17: External fixator

17

A. Schanz Pin 4. 5mm short threaded for diaphysis 5/6 mm long threaded for metaphysisB. Clamps 1) Universal Clamps 11) Open ended clamps 111) Transverse pin adjusting clamps 1v) Tube to tube clamps.

C. Tubes 11mm

Basic Components

Page 18: External fixator

18

Basic Components

Page 19: External fixator

19

Drill : Hand Drill

Drill bits – Long drill bits( 200mm) 3.5 and 4.5 mm diameter.

Triple guide assembly , consist of trocar(3.5mm), inner Sleeve and outer sleeve

T Handle for insertion of the Schanz pin.

Required instruments

Page 20: External fixator

20

Required instruments

Page 21: External fixator

21

Page 22: External fixator

22

Page 23: External fixator

23

severe open fractures (Gustilo 3b,3c)closed fractures with severe soft-tissue injury or severely comminuted fractures or floating knee #open fractures involving bone losscompartment syndrome after fasciotomyadjunct to internal fixationlimb lengthening or bone transportfracture associated with severe burnArthrodesisInfected fractures or nonunionsCorrection of malunionsFixation after radical tumor excision with autograft or allograft

Indications

Page 24: External fixator

24

Soft tissue healed If the soft-tissue injuries

have healed satisfactorily within 2 weeks without pin track infection, the external fixation can be removed.

It is then replaced by internal fixation with either a plate or a nail.

External fixator as temporary device

Page 25: External fixator

25

Soft-tissue problems persist Remove the external fixator Temporarily stabilize in cast Let pin track infection heal

If there is pin track infection, using a nail (especially with reaming technique) can lead to intramedullary infection.

In this case plate osteosynthesis is clearly preferable.

External fixator as temporary device

Page 26: External fixator

26

In the event that soft-tissue healing is not satisfactory after 4-6 weeks, and there is no pin track infection, the external fixator can be left on until the fracture has healed.

In children fracture healing is often completed within a period of approximately 6-8 weeks.

External fixation as final fixation

Page 27: External fixator

27

External fixation as final fixation

Page 28: External fixator

28

Less damage to blood supply of bone

Minimal interference with soft-tissue cover

Useful for stabilizing open fractures

Rigidity of fixation adjustable without surgery

Good option in situations with risk of infection Requires less experience and surgical skill than

standard ORIF Quite safe to use in cases of bone infection

Advantages

Page 29: External fixator

29

Pin Track Infection. Neurovascular Impalement. Muscle or Tendon Impalement Delayed Union. Compartment Syndrome Re-fracture Limitation of further Alternatives. Cosmetic Problem

Complications

Page 30: External fixator

30

IM nails vs External fixatorHenley (Clin. Orth., 1989) randomised study of

104 case II-IIIB tibial fractures by unreamed IM nail;

70 treated by external fixation.

Infection rates 7% IM nail, 11% external fixation.

There was no difference in time to union.

Follow up in 1998 (Journal Orth. Trauma.): “The severity

of soft tissue injury rather than the choice of implant

appears to be the predominant factor influencing

rapidity of bone healing and rate of infection”.

Page 31: External fixator

31

Open fracture Tibia and Fibula Open fracture Femur Floating Knee Open Fracture Humerus Communited fracture distal Radius Pelvic fracture.

Site of insertion

Page 32: External fixator

32

Tibial Safe Zone

Proximal part of the proximal tibia

Page 33: External fixator

33

Tibial Safe Zone

Proximal 3rd distal to tibial tuberosity

Page 34: External fixator

34

Tibial Safe Zone

Mid Shaft

Page 35: External fixator

35

Tibial Safe Zone

Distal 3rd distal of tibial Shaft

Page 36: External fixator

36

Schanz pin insertion

Page 37: External fixator

37

Schanz Pin insertion for Metaphysis

Page 38: External fixator

38

After adequate skin incision Insert assembled triple sleeve and push onto bone.

Hold the sleeve steady and lightly tap the trocer on to the bone surface in order to create the initial impression. This prevents slipping of the drill bit during drilling.

Page 39: External fixator

39

Remove the trocar, insert the long 3.5 drill bit through inner sleeve and drill through both cortices.

Withdraw the drill bit along with inner sleeve. Insert 4.5 mm drill bit through the outer sleeve and over drill the near cortex.

Technique of Applications

Page 40: External fixator

40

Place a 4.5 mm Schanz Pin onto the T-handle. Introduce through the outer sleeve and insert into the bone till the thread are securely engaged into the far cortex.

Technique of Applications

Page 41: External fixator

41

Insert the triple sleeve through an adequate skin incision and push onto bone.

Drill the both cortex bone with 3.5 mm drill bit.

Insert 5mm long threaded Schanz Pin with T-handle.

Technique of Applications for metaphysis

Page 42: External fixator

Place the most distal Schanz Pin using the standard technique.

Place a universal clamp onto the schanz pin

Fix a 11mm tube in this clamp, so that it is posterior to the schanz pin.

42

Application of external fixatorApplication of external fixator

Page 43: External fixator

43

Slide 3 Universal clamps onto this tube.

Insert most proximal schanz pin.

Reduction of bone.

Fix the proximal schanz pin.

Application of external fixator…Application of external fixator…

Page 44: External fixator

44

Insert the 3rd 4th schanz pin accordingly.

Connect frame with another Tube.

Second tube is clamped in “mirror image” fashion after prestressing.

Application of external fixator…Application of external fixator…

Page 45: External fixator

45

In the OT

Page 46: External fixator

46

In the OT

Open fracture Gustilo IIIB with Fixator

Page 47: External fixator

47

In the OT

Flap Coverage

Page 48: External fixator

Built as uni- and multi- plane constructs Areas prone to soft tissue problems

◦ Knee◦ Ankle◦ Open Fractures

When multiple injuries prevent definitive fixation

48

Page 49: External fixator

Spanning ex- fix if axially unstable

49

Page 50: External fixator

External fixation can be combined

with internal fixation

50

Page 51: External fixator

Temporary stabilization of long bone injuries in Temporary stabilization of long bone injuries in unstable patientunstable patient◦ Minimally invasiveMinimally invasive◦ Decreases bleedingDecreases bleeding◦ Pain controlPain control◦ Nursing careNursing care◦ ““Damage control”Damage control”

51

Page 52: External fixator

Certain intraarticular fracture can be treated by ex-fix using traction by fixator on the capsule and ligamentous structure around the joint.

This work well for comminuted intraarticular fracture of the distal radius.

52

Page 53: External fixator

Temporary stabilization for closed fracturesTemporary stabilization for closed fractures Controls hemorrhageControls hemorrhage Decreases clot shearDecreases clot shear Open pelvic fracturesOpen pelvic fractures

53

Page 54: External fixator

54

Ilizarov External Fixator.

Universal Mini external Fixator.

Modular external Fixator

Other External Fixators

Page 55: External fixator

55

Ilizarov External Fixator.

Page 56: External fixator

56

Ilizarov External Fixator.

Page 57: External fixator

57

Ilizarov External Fixator.

Page 58: External fixator

58

Micro-motion at fracture Site. It is bi-lateral More lighter than traditional External Fixator. More ligamentotasis Less chance of pin tract infections.

Page 59: External fixator

59

Page 60: External fixator

60

The modular external fixator allows the surgeon to reduce the fracture by manipulation and to hold the reduction.

Free pin placement allows the surgeon:

◦ to spread both pins, thereby increasing frame stiffness,

◦ to position pins according to the fracture pattern or soft-tissue injury,

◦ to avoid injury to nerves or vessels.

Page 61: External fixator

61

Page 62: External fixator

62

Synthes Tibial exfix Adjustable

Hoffman II external fixation system

Page 63: External fixator

63

External Fixator is a good device for the management of open and complicated fractures.

Surgeon must have knowledge about neurovascular plane of the involved Organ.

Skill for applying the fixator.

Page 64: External fixator

64

Campbell’s operative orthopedics

Wheeless' Textbook of Orthopaedics http://www.wheelessonline.com/ortho

Synthes: leading global medical device company. http://us.synthes.com/AO Foundation. <www.aofoundation.com>

Page 65: External fixator

65

Thank YouThank You