Pre PAT / PAT rocedure
-
8/19/2019 External Alarm New
2/28
2. Pre PAT
During pre PAT ensure the below points
• BTS layout
• Qua ty c ec o BTS RF umper VSWR E1 ca es EMU nsta at on etc.
• External Alarms verification with Emanco confirmation.
-
8/19/2019 External Alarm New
3/28
• Check if the Layout is matched with the Actual
Installation
• If found any mismatch escalate immediately
-
8/19/2019 External Alarm New
4/28
Quality check
• Check all the jumpers quality, should be as per
huawei standard
• Check E1 cable, alarm cable, power cables. All
standard, there should not be loop of any
cables. If loop is necessary put it inside the
BTS cabinet.
• EMU installation must be standardized.
-
8/19/2019 External Alarm New
5/28
• How to
check
Polarit
• How to check Normally Open and Normally
• How to connect Alarms on EMU
• How to connect Alarms on BATB
• How to
test
alarms
from
civil
end
• Siemens Rectifier Alarms connectivity
-
8/19/2019 External Alarm New
6/28
• 100% accurate test – Mark the cables of one alarm pair as Front Side BATB and Back side BATB as per the existing connections
– Then Remove this alarm pair from BATB Telecom Side (Siemens)
–
Tune
multimeter to
DC
Voltage – Connect Red pole from multimeter to the cable marked as Front side BATB
– Connect Black pole from multimeter to the cable marked as Back side BATB
– If the value is Positive then cable marked as Front side BATB is Positive and the cable marked as Back side BATB is negative
– If the value is negative then cable marked as Front side BATB is negative and the Back side BATB is positive
–
• 99 % sites which is having BATA civil end Black is Negative (Common) and White is Positive, check figure‐1
• In some cases the Ne ative common is loo with each other exam le check fi ure‐2
• In sites not having BATB do same testing on the Siemens Krone, Disconnect one alarm, mark the cables and test by above procedure.
-
8/19/2019 External Alarm New
7/28
Figure‐1 Polarization from BATB civil End
White is
positive
-
8/19/2019 External Alarm New
8/28
Figure‐2 Polarity should be checked before swap, make sure common
(loop) is negative
-
8/19/2019 External Alarm New
9/28
-
8/19/2019 External Alarm New
10/28
How to check Normally Open and Normally Closed
• 100% Accurate Testing:
–
– Disconnect alarms from Telecom side (Siemens)
– Tune multimeter on
Buzzer
– Check i there is buzzer on the civil side
– If there is buzzer means normally closed
– If there is no buzzer means normally open
–
The
Alarms
currently
coming
(Active)
will
have
opposite
status,
• For example if AC‐1 alarm is coming
• Check if buzzer is received on all other alarms and no buzzer on AC‐1 alarm
• s means a a a arms are norma y c ose
• And if there is buzzer on AC‐1 alarm and other alarms no buzzer.
• This means that all alarms normally open.
-
8/19/2019 External Alarm New
11/28
s n o sensor w e norma y open, a erent n o oor
sensor it will normally closed
-
8/19/2019 External Alarm New
12/28
How to connect A arms on EMU an
Alarm ID Cable Label Color Code New Alarm Name Sever ity
65101 Blue (+) / White Blue (‐) Telecom shelter air condition #1 fault Minor
Alarm‐1 (1‐4)65102 Orange (+) / White Orange (‐) Telecom shelter air condition #2 fault Minor
65103 Green (+) / White Green (‐) Telecom/General shelter fire alarm Critical
65104 Brown (+) / White Brown (‐) Telecom/General shelter door alarm Critical
65105 Blue (+)
/ White
Blue
(‐) Telecom shelter h igh temperature alarm Critical
Alarm‐2 (5‐8) ‐
65107 Green (+) / White Green (‐) Telecom shelter tower light alarm Warning
65108 Brown (+) / White Brown (‐) Telecom shelter battery discharge/ commercial power Critical
65109 Blue (+) / White Blue (‐) Generator #1 fault Major
65110 Orange (+) / White Orange (‐) Telecom shelter power fail major Criticalarm‐ ‐
65111 Green (+) / White Green (‐) Generator #1 running(indication) Warning
65112 Brown (+) / White Brown (‐) Generator low fuel – day tank Warning
65113
Alarm‐4 13‐16
Blue (+) / White Blue (‐) Generator low fuel – storage tank Warning
65114 Orange (+) / White Orange (‐) Telecom shelter commercial power fail Critical
65115 Green (+) / White Green (‐) Generator #2 fault Major
65116 Brown (+) / White Brown (‐) Generator #2 running(indication) Warning
65117
Alarm‐5
(17
‐20)
Blue (+) / White Blue (‐) Telecom/ Generator shelter FM200 released/ FA fault Warning
65118 Orange
(+)
/
White
Orange
(‐
) Telecom shelter high humidi ty alarm Warning ‐ -
65120 Brown (+) / White Brown (‐) Telecom shelter OPP alarm Warning
65121
Alarm‐6 (21‐24)
Blue (+) / White Blue (‐) DSX Fuse Warning
65122 Orange (+) / White Orange (‐) Micro Wave Major Warning
65123 Green (+) / White Green (‐) Micro Wave Minor Warning
65124 Brown (+) / White Brown (‐) Micro Wave Remote Warning
65125 Alarm‐7 (25‐26) Blue (+) / White Blue (‐)Generator low fuel #2– day tank Warning
65126 Orange (+) / White Orange (‐) TTA ALARM Warning
-
8/19/2019 External Alarm New
13/28
Civil Side with BATB Alarm ID New Alarm Name Color Code
Krone Block &
pos
Alarm Name
Siemens
Sensor cables
Signal Ground
65101 Telecom shelter air cond ition #1 fault
Alarm‐1 (1‐4)
Blue (+) / White Blue (‐) A.1 AC‐1 BE/WH WH/BE
65102 Telecom shelter air cond ition #2 fault Orange (+) / White Orange (‐) A.2 AC‐2 WH/OR
65103 Telecom/General shelter fi re alarm Green + White Green ‐ A.3 Fire Alarm WH BE BE WH
65104 Telecom/General shelter door alarm Brown (+) / White Brown (‐) A.5 Shelter Door WH/BE BE/WH
65105 Telecom shelter high temperature alarm
Alarm‐2 (5‐8)
Blue (+) / White Blue (‐) A.6 High Temp OR/WH
65106 Telecom shelter minor power fail(minor) Orange (+)
/ White
Orange
(‐) A.8 Minor
Power
fail GN WH/BE
65107 Telecom shelter tower l i ht alarm Green (+) / White Green (‐) A.10 Tower Light WH/BE BE/WH
65108 Telecom shelter battery discharge/ commercial
power Brown (+) / White Brown (‐) B.1 Batt Discharge BE/WH WH/BE
65109 Generator #1 fault
Alarm‐3 (9‐12)
Blue (+) / White Blue (‐) B.2 General Diesel
65110 Telecom shelter power fail major Orange (+) / White Orange (‐) B.3 Major Power fail BK WH
65111 Green + / White Green ‐ B.4 Diesel Runnin 1
65112 Generator low fuel – day tank Brown (+) / White Brown (‐) B.5 Low Diesel fuel 1
65113 Generator low fuel – storage tank
Alarm‐4 (13‐16)
Blue (+) / White Blue (‐) B.7 Storage Tank
65114 Telecom shelter commercial power fail Orange (+) / White Orange (‐) B.8 Mains Fail
65115 Generator #2 fault Green (+) / White Green (‐) B.9 General Diesel
65116 Generator #2 running(indication) Brown + W ite Brown ‐ B.10 Diese Running 2
65117Telecom/ Generator shelter FM200 released/ FA
fault
Alarm‐5 (17‐20)
Blue (+) / White Blue (‐) C.2 White Released WH/BE BE/WH
65118 Telecom shelter high humidity alarm Orange (+) / White Orange (‐) C.3 High Humidity
65119 Telecom shelter battery/ AC fail-access control Green (+)
/ White
Green
(‐)
Telecom shelter OPP alarm rown + e rown ‐
65121 DSX Fuse
Alarm‐6 (21‐24)
Blue (+) / White Blue (‐) A.9 DSX Fuse WH/BN BN/WH
65122 Micro Wave Major Orange (+) / White Orange (‐)
65123 Micro Wave Minor Green (+) / White Green (‐) A.4 Microwave Minor WH/GN GN/WH
65124 Micro Wave Remote Brown (+) / White Brown (‐) A.7 Microwave Remote WH/OR OR/WH
65125 Generator low fuel #2– day tankAlarm‐7 (25‐26)
Blue (+) / White Blue (‐) C.1 Low Diesel fuel 2
65126 TTA ALARM Orange (+)
/ White
Orange
(‐)
-
8/19/2019 External Alarm New
14/28
-
8/19/2019 External Alarm New
15/28
1) EMU side should be standard as in attached
-
8/19/2019 External Alarm New
16/28
How to connect Alarms on BATB
-
8/19/2019 External Alarm New
17/28
How to test Alarms from Civil End
‐ , ‐ , , ,
there is
one
orange
color
strip
on
top
of
the
relay
just
turn
it
to
the
top
direction
and
alarm
will
be trigger.
‐
Relay R4: AC‐2
Relay
R5:
High
Temp
-
8/19/2019 External Alarm New
18/28
Relay R4: AC‐2
-
8/19/2019 External Alarm New
19/28
Relay R5: High Temp
-
8/19/2019 External Alarm New
20/28
Relay R6: High Humidity
-
8/19/2019 External Alarm New
21/28
How to connect Siemens Rectifier Alarms
Only if there are cables connected on the below mention ports
-
8/19/2019 External Alarm New
22/28
• Disconnect the cables from the port and connect one jumper from
here to BATB (civil side) and from BATB connect these alarms as per
•
In
Siemens
Rectifier
Black
is
+ive,
Blue
is
–ive(Common)
-
8/19/2019 External Alarm New
23/28
– 149: Battery Discharge
– : ower a or
–
+
ser es connec on:
– connected to BATB as usual.
-
8/19/2019 External Alarm New
24/28
Series Connection for Minor Alarm for cables
+
-
8/19/2019 External Alarm New
25/28
• Polarization from BATB civil End – Black is negative
• From Telecom End the solid color is +ive, Dashed (white with color) is –ive.
• In Siemens Rectifier Black is +ive, Blue is –ive(for alarms directly connected)
• Connectivity for
Siemens
Rectifier:
– 149: Battery Discharge
– 147: Power Major
– 146+148 series connection: Power Minor
– Commercial Power will be connected to BATB as usual.
• How to generate AC‐1, AC‐2, High Temp, High Humidity Alarm Having Cylon Controller only,
there is
one
orange
color
strip
on
top
of
the
relay
just
turn
it
to
the
top
direction
and
alarm
will be trigger. – Relay R3: AC‐1
– Relay R4: AC‐2
– Rleay R5: High Temp
– Relay R6: High Humidity
• In
new
MDB
of
big
size
we
can
generate
Commercial
Power
Alarm,
once
we
switch
off
commerc a power we w rece ve e ow a arms: – Commercial power alarm
– FM 200 Released
– AC ControlMicrosoft Office
Excel Worksheet
– Battery Discharge
•
Sites having
Controller
different
than
Cylon and
having
BATB,
check
the
alarms
one
by
one
by
disconnecting cables from civil end one by one.
-
8/19/2019 External Alarm New
26/28
1) Labeling(example in attach sheet)
2) Heat Shrink for the connectivity of Siemens Rectifier Alarms
-
8/19/2019 External Alarm New
27/28
-
8/19/2019 External Alarm New
28/28
From Telecom End the solid color is +ive,
Dashed (white with color) is –ive.