![Page 1: Exterior Scene 1 / Luminaire parts list - LUXSUN - Home ... · PDF fileExterior Scene 1 / Luminaire parts list 8 Pieces Flood light FL-300S-30D ... Exterior Scene 1 / Tennis 1 Calculation](https://reader035.fdocuments.in/reader035/viewer/2022062908/5aba8c2f7f8b9a321b8bc8ab/html5/thumbnails/1.jpg)
Project 1
13.01.2017
OperatorTelephone
Faxe-Mail
Exterior Scene 1 / Luminaire parts list
8 Pieces Flood light FL-300S-30DArticle No.: Luminous flux (Luminaire): 38742 lmLuminous flux (Lamps): 38763 lmLuminaire Wattage: 306.1 WLuminaire classification according to CIE: 100CIE flux code: 89 95 99 100 100Fitting: 1 x FL-300S-30D (Correction Factor 1.000).
See our luminaire catalog for an image of
the luminaire.
Page 1
![Page 2: Exterior Scene 1 / Luminaire parts list - LUXSUN - Home ... · PDF fileExterior Scene 1 / Luminaire parts list 8 Pieces Flood light FL-300S-30D ... Exterior Scene 1 / Tennis 1 Calculation](https://reader035.fdocuments.in/reader035/viewer/2022062908/5aba8c2f7f8b9a321b8bc8ab/html5/thumbnails/2.jpg)
Project 1
13.01.2017
OperatorTelephone
Faxe-Mail
Exterior Scene 1 / Sport Luminaires (Coordinates List)
Scale 1 : 322
List of the Sport Luminaires
Luminaire Index Position [m] Aiming Point [m] Angle [°] Alignment PoleX Y Z X Y Z
Flood light FL-300S-30D 1 -8.826 -7.750 10.000 -9.748 -2.217 0.000 60.7 (C 90, G IMax) /
Flood light FL-300S-30D 2 8.826 -7.750 10.000 9.748 -2.217 0.000 60.7 (C 90, G IMax) /
Flood light FL-300S-30D 3 -8.826 7.750 10.000 -9.748 2.217 0.000 60.7 (C 90, G IMax) /
Flood light FL-300S-30D 4 8.826 7.750 10.000 9.748 2.217 0.000 60.7 (C 90, G IMax) /
Page 1
![Page 3: Exterior Scene 1 / Luminaire parts list - LUXSUN - Home ... · PDF fileExterior Scene 1 / Luminaire parts list 8 Pieces Flood light FL-300S-30D ... Exterior Scene 1 / Tennis 1 Calculation](https://reader035.fdocuments.in/reader035/viewer/2022062908/5aba8c2f7f8b9a321b8bc8ab/html5/thumbnails/3.jpg)
Project 1
13.01.2017
OperatorTelephone
Faxe-Mail
Exterior Scene 1 / 3D Rendering
Page 1
![Page 4: Exterior Scene 1 / Luminaire parts list - LUXSUN - Home ... · PDF fileExterior Scene 1 / Luminaire parts list 8 Pieces Flood light FL-300S-30D ... Exterior Scene 1 / Tennis 1 Calculation](https://reader035.fdocuments.in/reader035/viewer/2022062908/5aba8c2f7f8b9a321b8bc8ab/html5/thumbnails/4.jpg)
Project 1
13.01.2017
OperatorTelephone
Faxe-Mail
Exterior Scene 1 / False Color Rendering
Page 1
![Page 5: Exterior Scene 1 / Luminaire parts list - LUXSUN - Home ... · PDF fileExterior Scene 1 / Luminaire parts list 8 Pieces Flood light FL-300S-30D ... Exterior Scene 1 / Tennis 1 Calculation](https://reader035.fdocuments.in/reader035/viewer/2022062908/5aba8c2f7f8b9a321b8bc8ab/html5/thumbnails/5.jpg)
Project 1
13.01.2017
OperatorTelephone
Faxe-Mail
Exterior Scene 1 / Tennis 1 Calculation Grid (PA) / Isolines (E, Perpendicular)
Values in Lux, Scale 1 : 258Position of surface in external scene:Marked point: (-18.000 m, -9.000 m, 0.100 m)
Grid: 15 x 7 Points
Eav
[lx] Emin
[lx] Emax
[lx] u0 Emin
/ Emax
335 20 770 0.06 0.03
Page 1
![Page 6: Exterior Scene 1 / Luminaire parts list - LUXSUN - Home ... · PDF fileExterior Scene 1 / Luminaire parts list 8 Pieces Flood light FL-300S-30D ... Exterior Scene 1 / Tennis 1 Calculation](https://reader035.fdocuments.in/reader035/viewer/2022062908/5aba8c2f7f8b9a321b8bc8ab/html5/thumbnails/6.jpg)
Project 1
13.01.2017
OperatorTelephone
Faxe-Mail
Exterior Scene 1 / Tennis 1 Calculation Grid (PA) / Greyscale (E, Perpendicular)
Scale 1 : 258Position of surface in external scene:Marked point: (-18.000 m, -9.000 m, 0.100 m)
Grid: 15 x 7 Points
Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax
335 20 770 0.06 0.03
Page 1
![Page 7: Exterior Scene 1 / Luminaire parts list - LUXSUN - Home ... · PDF fileExterior Scene 1 / Luminaire parts list 8 Pieces Flood light FL-300S-30D ... Exterior Scene 1 / Tennis 1 Calculation](https://reader035.fdocuments.in/reader035/viewer/2022062908/5aba8c2f7f8b9a321b8bc8ab/html5/thumbnails/7.jpg)
Project 1
13.01.2017
OperatorTelephone
Faxe-Mail
Exterior Scene 1 / Tennis 1 Calculation Grid (PA) / Value Chart (E, Perpendicular)
Values in Lux, Scale 1 : 258
Position of surface in external scene:Marked point: (-18.000 m, -9.000 m, 0.100 m)
Grid: 15 x 7 Points
Eav
[lx] Emin
[lx] Emax
[lx] u0 Emin
/ Emax
335 20 770 0.06 0.03
Page 1