電力系統節能暨負載管理 - ftis.org.tw · 功率因數偏低,會使線路總電流增大,且造成線路及變 電設備的損失增加。依台電公司有關規定:
Ext. PSU SPECIFICATION FOR APPROVAL · A2 13.10.23...
Transcript of Ext. PSU SPECIFICATION FOR APPROVAL · A2 13.10.23...
-
Ideal Power LtdIdeal Power, Ideal House, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, EX32 7NZ, England, UK Tel: +44 (0) 845 260 3400 Email: [email protected] Web: www.idealpower.co.uk
Ideal Power Ltd Product Specification Document
I.T.E POWER SUPPLY
110370-0317 FEB.18th.2014
(A3)
HK-AJ-090A200-CP HKSC-110370
VENDOR APPROVED SIGNATURES
DATE:
CUSTOMER APPROVED SIGNATURES
PART NO:
SPECIFICATION FOR APPROVAL
DESIGNED NO:
MODEL NO:
DESCRIPTION:
CUSTOMER:
REV:
繪圖員2014.02.18
何寶玲
工程師2014.02.18歐陽建瓊
經 理2014.02.18田青松
Ideal Power, 14 Larks Way, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, England EX32 7NZ
Web: www.idealpower.co.uk email: [email protected] TEL +44 (0) 845 2603400 Fax +44 (0) 845 2603401
Description Ext. PSU
Model Number 25HK-AJ-090A200-CP
Revision A3
Notes -
-
Ideal Power LtdIdeal Power, Ideal House, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, EX32 7NZ, England, UK Tel: +44 (0) 845 260 3400 Email: [email protected] Web: www.idealpower.co.uk
SAFETY APPROVAL:ENGINEER APPROVAL:
ELECTRICAL STRUCTURAL
MODEL NO REV
PART NO
REMARKSDESCRIPTION
SPECIFICATION CHANGE HISTORY
QR-工-26A
REV DATE
CUSTOMER HKSC-110370
HK-AJ-090A200-CP (A3)
歐陽建瓊 胡 鵬張偉松
Ideal Power
馮 丹3.將 C-TICK 改為 RCM, (Label change C-Tick to RCM)2.更新FCC Logo (Update new FCC logo)1.更新新的IP logo(Update the new logo ).
13.10.21A1
13.10.23A2 2.銘板增加PSE安規,承認書第15項增加PSE安規信息
(Add Individual Cartons Label 1: 1.在白盒上蓋加印客戶P/N 和 RoHSP/N: 25HK-AJ-090A200-CP & also the RoHS label)
Add the PSE logo on the label and information under Point 15.0 SAFETY3.更新8 pin 連接器圖片 (Update the 8 way connector)
馮 丹
14.02.18A31.更新EMC標準和加法文警告標語.(update EMC standard and French warning words)2.更新銘板上的安規logo.(Update the safety logo on the label)3.更新8 pin 連接器圖片.(Update the 8 way connector)
何寶玲
Page 2 of 13
-
Ideal Power LtdIdeal Power, Ideal House, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, EX32 7NZ, England, UK Tel: +44 (0) 845 260 3400 Email: [email protected] Web: www.idealpower.co.uk
11. PROTECTION10. INSULATION RESISTANCE9. DIELECTRIC STRENGTH (Hi-Pot) TEST
14. RELIABILITY AND QUALITY CONTROL15. SAFETY16. OVERALL DRAWING
19. MARKING18. PACKING
12. ENVIRONMENTAL CONDITIONS13. EMI/ EMC
1. INTRODUCTION2. INPUT REQUIREMENTS
5. LINE REGULATION6.HOLD UP TIME7.TURN ON TIME8.TEMPERATURE COEFFICIENT
3. OUTPUT REQUIREMENTS4. EFFICIENCY
DESCRIPTION : I.T.E POWER SUPPLY
MODEL NO. :PART NO. :
CONTENTS
2014.02.18REV: (A3)
PAGE NO. : ISSUED DATE:
17. USE SPECIFICATION
1 OF 12HKSC-110370
HK-AJ-090A200-CP
20. TEST REPORT
Web: www.idealpower.co.uk email: [email protected] TEL +44 (0) 845 2603400 Fax +44 (0) 845 2603401 Ideal Power, 14 Larks Way, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, England EX32 7NZ
Page 3 of 13
-
Ideal Power LtdIdeal Power, Ideal House, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, EX32 7NZ, England, UK Tel: +44 (0) 845 260 3400 Email: [email protected] Web: www.idealpower.co.uk
2.2 Input Frequency Range: 47 Hz to 63 Hz 2.1 Input Voltage Range: 100(-10%)VAC to 240(+10%)VAC
This document specifies a switching power supply with a output of +9V, and electronic process. The switching power supply will provide power for technology equipments including electrical business equipment.The adaptor meets the requirement of lead free and RoHS.
PAGE NO. :
REV: (A3)ISSUED DATE:
3.3 Output Load Range: 2.0A
2.4 Input In-rush Current: 50A Max
2.5 Input Current: 0.8A Max
3.2 Output Regulation:
3.1 Output Voltage: 3.0 OUTPUT REQUIREMENTS
+9V
8.55-9.45V
2.0 INPUT REQUIREMENTS
PART NO. : MODEL NO. :
DESCRIPTION : I.T.E POWER SUPPLY
1.0 INTRODUCTION
2014.02.182 OF 12HK-AJ-090A200-CP
HKSC-110370
2.3 Input Power Consumption at no-load : 0.3W Max
≧80.40%
3.4 Output Ripple & Noise: 200mV Max @20MHz bandwidth with
7.0 TURN ON TIME: 2S Max at 110VAC full load.
10UF/50V capacitance and 104/50V ceramic capacitor.
4.0 EFFICIENCY: @ average of 25/50/75/100% loads &115/230VAC input
6.0 HOLD UP TIME: 10ms Min at 110VAC full load.
5.0 LINE REGULATION: ±2% maximum
Web: www.idealpower.co.uk email: [email protected] TEL +44 (0) 845 2603400 Fax +44 (0) 845 2603401 Ideal Power, 14 Larks Way, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, England EX32 7NZ
Page 4 of 13
-
Ideal Power LtdIdeal Power, Ideal House, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, EX32 7NZ, England, UK Tel: +44 (0) 845 260 3400 Email: [email protected] Web: www.idealpower.co.uk
overload shall provide automatic recovery for the output voltage.
11.2.2 Short Circuit Protection: Auto Recovery.
11.2 Output Protection
11.2.1 Output Current:
The switching power supply has a 2 Amps inner current fuse to protect itself.
9.2 Finished product withstands AC 3.0KV, for 2 second, 4mA Max primary to
9.1 Finished product withstands AC 3.0KV, for 2 second, 4mA Max primary to
PAGE NO. :
REV: (A3)ISSUED DATE:
secondary.
11.1 Input Protection
11.0 PROTECTION
10.0 INSULATION RESISTANCE
9.0 DIELECTRIC STRENGTH (Hi-Pot) TEST
Primary to secondary: 50M OHM to 500VDC.
8.0 TEMPERATURE COEFFICIENT: 0.05%/°C
MODEL NO. :PART NO. :DESCRIPTION : I.T.E POWER SUPPLY
2014.02.18
case.
3 OF 12HK-AJ-090A200-CP
HKSC-110370
Overload conditions shall decrease the output voltage Removal of an
output
Web: www.idealpower.co.uk email: [email protected] TEL +44 (0) 845 2603400 Fax +44 (0) 845 2603401 Ideal Power, 14 Larks Way, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, England EX32 7NZ
Page 5 of 13
-
Ideal Power LtdIdeal Power, Ideal House, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, EX32 7NZ, England, UK Tel: +44 (0) 845 260 3400 Email: [email protected] Web: www.idealpower.co.uk
The burn-in test will be performed at least 2 hours at 40 centigrade degrees
When the operation is compling with this specification, the switching power supply s MTBF will be 50,000 hours at 25 centigrade degrees.
The switching power supply can withstand the following environmental conditions:
ISSUED DATE:REV: (A3)
PAGE NO. :
14.1 Burn-in
under full load condition. 14.2 MTBF
15.0 SAFETY
13.0 EMI / EMC
Relative Humidity: 10% ~ 95%
Relative Humidity: 10%~95%
12.1 Storage Temperature:-20℃ ~ +70 ℃
12.2 Operation
14.0 RELIABILITY AND QUALITY CONTROL
Temperature:0°C~40°C
12.0 ENVIRONMENTAL CONDITIONS
DESCRIPTION : I.T.E POWER SUPPLYPART NO. : MODEL NO. :
2014.02.184 OF 12HK-AJ-090A200-CP
HKSC-110370
(1)EN55022(EN61000-3-2. EN61000-3-3) FCC PART 15B
IEC61000-4-6. IEC61000-4-8. IEC61000-4-11.) (2)EN55024(IEC61000-4-2. IEC61000-4-3. IEC61000-4-4. IEC61000-4-5.
The switching power supply has approved by the following standards:
The switching power supply has approved by the following safety standards: UL60950-1 2nd Edition ,2007-03-27 CSA C22.2 NO.60950-1-07,2nd Edition.2007-03 EN60950-1: 2006+A11+A1+A12AS/NZS 60950-1:2003 inc amendment1,2&3. BS EN60950-1: 2006+A1+A12
AS/NZS 55022/55024
Web: www.idealpower.co.uk email: [email protected] TEL +44 (0) 845 2603400 Fax +44 (0) 845 2603401 Ideal Power, 14 Larks Way, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, England EX32 7NZ
J55022(H22)
Page 6 of 13
-
Ideal Power LtdIdeal Power, Ideal House, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, EX32 7NZ, England, UK Tel: +44 (0) 845 260 3400 Email: [email protected] Web: www.idealpower.co.uk
UNIT: mm
DESCRIPTION : I.T.E POWER SUPPLY
16. OVERALL DRAWING
MODEL NO. :PART NO. :
REV: (A3)2014.02.18
PAGE NO. :ISSUED DATE:
5 OF 12HK-AJ-090A200-CP
HKSC-110370
Small ODSafety Marking
88.5±1
46.0±136.0±1
35-J不加強筋
4.9±0.3
10.5±0.5
8.1±0.3
1.5*31.6
TIP 27
.3±0
.2
10±0.5
16.8
±0.5 2.1±
0.2
1.2*3
未注標尺寸公差:±0.2
可換頭
1830±30
(印安規字) (白條邊)
TIP
TIP
AWG#20
Web: www.idealpower.co.uk email: [email protected] TEL +44 (0) 845 2603400 Fax +44 (0) 845 2603401 Ideal Power, 14 Larks Way, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, England EX32 7NZ
Page 7 of 13
-
Ideal Power LtdIdeal Power, Ideal House, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, EX32 7NZ, England, UK Tel: +44 (0) 845 260 3400 Email: [email protected] Web: www.idealpower.co.uk
REV: (A3)
PAGE NO. : ISSUED DATE:
DESCRIPTION : I.T.E POWER SUPPLYPART NO. : MODEL NO. :
2014.02.186 OF 12HK-AJ-090A200-CP
HKSC-110370
HK-04N20286
2.5A 250V~
HK-03
2.5A 250V~EN 60320-1
HON-KWANG
2.5A250V~HK-02
HON-KWANG
A 46
B2.5A125V~E246753HK-01
ESP
46.0±1
88.5±1
88.5±1
46.0±1
36.0±1
36.0±1
36.0±1
36.0±1
UNIT: mmUNIT: mm
UL TUV
UK SAA
Web: www.idealpower.co.uk email: [email protected] TEL +44 (0) 845 2603400 Fax +44 (0) 845 2603401 Ideal Power, 14 Larks Way, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, England EX32 7NZ
Page 8 of 13
-
Ideal Power LtdIdeal Power, Ideal House, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, EX32 7NZ, England, UK Tel: +44 (0) 845 260 3400 Email: [email protected] Web: www.idealpower.co.uk
HKSC-110370
HK-AJ-090A200-CP 7 OF 122014.02.18
DESCRIPTION : I.T.E POWER SUPPLYPART NO. : MODEL NO. :
ISSUED DATE:REV: (A3)
PAGE NO. :
Web: www.idealpower.co.uk email: [email protected] TEL +44 (0) 845 2603400 Fax +44 (0) 845 2603401 Ideal Power, 14 Larks Way, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, England EX32 7NZ
8.1±0.3
TIP
TIP
TIP
TIP 27
.3±0
.2
27.3
±0.2
TIP
TIP 27
.3±0
.2
TIP 27
.3±0
.2
TIP
8.1±0.38.1±0.38.1±0.3
10±0.5
8.1±0.3
27.3
±0.2
TIP
UNIT: mmUNIT: mm
Page 9 of 13
-
Ideal Power LtdIdeal Power, Ideal House, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, EX32 7NZ, England, UK Tel: +44 (0) 845 260 3400 Email: [email protected] Web: www.idealpower.co.uk
DESCRIPTION : I.T.E POWER SUPPLY
MODEL NO. :PART NO. :
REV: (A3)2014.02.18
PAGE NO. :ISSUED DATE:
17. USE SPECIFICATION
8 OF 12HK-AJ-090A200-CP
HKSC-110370
Please don't insert article alone at the wall.
WARNING!TI
PT
IP
TIP
TIP
Web: www.idealpower.co.uk email: [email protected] TEL +44 (0) 845 2603400 Fax +44 (0) 845 2603401 Ideal Power, 14 Larks Way, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, England EX32 7NZ
∅1.7
∅4.0∅4.75
∅1.7 ∅1.3
∅3.4
∅2.5
∅5.5 ∅5.5
∅2.1
∅5.5
∅2.1
∅6.3
∅3.0 ∅0.7
∅2.35
TIP
TIP
TIP
TIP
Instruction manual card
Page 10 of 13
-
Ideal Power LtdIdeal Power, Ideal House, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, EX32 7NZ, England, UK Tel: +44 (0) 845 260 3400 Email: [email protected] Web: www.idealpower.co.uk
2014.02.18REV: (A3)
18.1 Inner BoxUNIT: mm
DESCRIPTION : I.T.E POWER SUPPLY
MODEL NO. :
18. PACKING
PART NO. :PAGE NO. :ISSUED DATE:
9 OF 12HK-AJ-090A200-CP
HKSC-110370
注意:樣品使用的小白盒尺寸可能與此圖面尺寸不同,此圖面尺寸是用于生產 時的包裝.
NOTICE:Its probably different from the white box of the sample and the figure dimension. The white box is used to pack during product.
Length: 143
Height: 60
Width: 70
Web: www.idealpower.co.uk email: [email protected] TEL +44 (0) 845 2603400 Fax +44 (0) 845 2603401 Ideal Power, 14 Larks Way, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, England EX32 7NZ
6
24
P/N:25HK-AJ-090A200-CP
Label: 1Label: 2
Width
Length
Height
Open Side
印刷于此
Material:A卡400磅(0.53t)White
6
24
RoHS
Label: 2
Label: 1
Page 11 of 13
-
Ideal Power LtdIdeal Power, Ideal House, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, EX32 7NZ, England, UK Tel: +44 (0) 845 260 3400 Email: [email protected] Web: www.idealpower.co.uk
18.2 Carton
UNIT: mm
100V~240V
200V~240V
100V~120V
MODEL:
N.W.:
G.W.:
Q'TY: 60PCS
100V~120V
100V~240V
200V~240V
DESCRIPTION : I.T.E POWER SUPPLY
MODEL NO. :
18. PACKING
PART NO. :PAGE NO. :ISSUED DATE:REV: (A3)
2014.02.1810 OF 12HK-AJ-090A200-CP
HKSC-110370
(Transverse Plane)
440
250
360
Web: www.idealpower.co.uk email: [email protected] TEL +44 (0) 845 2603400 Fax +44 (0) 845 2603401 Ideal Power, 14 Larks Way, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, England EX32 7NZ
Page 12 of 13
-
Ideal Power LtdIdeal Power, Ideal House, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, EX32 7NZ, England, UK Tel: +44 (0) 845 260 3400 Email: [email protected] Web: www.idealpower.co.uk
19. MARKING
UNIT: mm
DESCRIPTION : I.T.E POWER SUPPLY
MODEL NO. :PART NO. :
PAGE NO. :
REV: (A3)ISSUED DATE: 2014.02.18
11 OF 12HK-AJ-090A200-CP
HKSC-110370
year
M M Y Y C
month
made in China by Hon-kwang
Web: www.idealpower.co.uk email: [email protected] TEL +44 (0) 845 2603400 Fax +44 (0) 845 2603401 Ideal Power, 14 Larks Way, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, England EX32 7NZ
200# CPC 合成紙+上光 NAME-PLATE:WHITE CHARACTERS BLACK BACKGROUND.
ĽINTÉRIEUR SEULEMENTPOUR UTILISATION À ATTENTION
ID 0000019930
Sicherheitgeprufte
TUVRheinlandR
www.tuv.com
I.T.E POWER SUPPLY
LPS
R2.0
INPUTOUTPUT
MODEL
60YM E202402
: 100-240V 50/60Hz 0.8A: 9V 2.0A
: HK-AJ-090A200-CP
31.8+0.0-0.2
BS EN 60950-1TUVRheinland Group
19.8+0.0-0.2
2.5
2.5 MADE IN CHINA MMYYC
P SE
入力:
JET9V 2.0A出力:100V 50/60Hz 0.8A 41VA
輸入事業者