Experion SCADA and the Long Reach of Control

25
and the Long Reach of Control EXPERION SCADA Paul Vellacott 20 June 2016

Transcript of Experion SCADA and the Long Reach of Control

Page 1: Experion SCADA and the Long Reach of Control

and the Long Reach of ControlEXPERION SCADAPaul Vellacott

20 June 2016

Page 2: Experion SCADA and the Long Reach of Control

© 2016 by Honeywell International Inc. All rights reserved.

2

Where do you think I

come from? Longreach?

Page 3: Experion SCADA and the Long Reach of Control

© 2016 by Honeywell International Inc. All rights reserved.

3

Page 4: Experion SCADA and the Long Reach of Control

© 2016 by Honeywell International Inc. All rights reserved.

4

Page 5: Experion SCADA and the Long Reach of Control

© 2016 by Honeywell International Inc. All rights reserved.

5

Page 6: Experion SCADA and the Long Reach of Control

© 2016 by Honeywell International Inc. All rights reserved.

Experion SCADA & the Long Reach of Control

6

Page 7: Experion SCADA and the Long Reach of Control

© 2016 by Honeywell International Inc. All rights reserved.

Experion SCADA & the Long Reach of Control

7

2013

2012

2014

2017

2015

2016

Experion R410300,000 SCADA Points

Improved ControlLogix

Interface

OPC Non-scanned

parameters

SCADA Point Processing

New Calculation Algos

Dynamic Alarm Suppression

Alarm Tracker

ACM Alarm Help

64-bit OS support

+++ much more

Experion R430Pan & Zoom Displays

Equipment Templating &

Displays

5,000 Controllers / RTUs

Scanning Sub-system

Enhancements

EFM Data Collection &

handoff

Gas Operations Suite

Experion R431New Protocols:

Flow-X EFM

Bristol Babcock EFM

IEC 61850 Configuration

Efficiencies

Experion R500 *Configuration Management of Change

New SCADA Protocols for EFMs

IEC 61850 SCADA Interface Update

SCADA Point Enhancement

RTU2020 Integration

Third Party Package Configuration Efficiency

Backup Control Center (native)

Operational Application Suite Enhancements

Page 8: Experion SCADA and the Long Reach of Control

© 2016 by Honeywell International Inc. All rights reserved.

Backup Control Center

Better Availability for Critical Infrastructure Protection

8

Page 9: Experion SCADA and the Long Reach of Control

© 2016 by Honeywell International Inc. All rights reserved.

Backup Control Center

Better Availability for Regulatory Compliance

9

Page 10: Experion SCADA and the Long Reach of Control

© 2016 by Honeywell International Inc. All rights reserved.

EFM Protocols with EFM Export Option

Reduce Costs with One System to Collect All Data

- Enron Modbus

- Flow-X EFM

- Bristol Babcock EFM

- Omni

- Emerson ROC

- ABB TotalFlow

- Honeywell RTU2020

• Export to:

- FlowCal (CFX files) or

- CSV file

• Support for Gas & Liquids EFMs

- Gas: API 21.1

- Liquids: API 21.2

10

R431

R500

R500

R430

SCADA

Interface

Experion

Server

Monitoring &

Control

Electronic Flow Meter

Experion

StationGas

Management

EFM Repository

•Transaction records

•Audit Events

•Configuration

CFX / CSV

export

Transaction record collection integratedinto polling engine

Page 11: Experion SCADA and the Long Reach of Control

© 2016 by Honeywell International Inc. All rights reserved.

Quick Builder Concurrent Users & MOC

Supports API 1168 Recommended Practice for Pipeline Control Room Management

Up to 12 concurrent Users

- A ‘LEAP’ enabler

Plus Management of Change

- Who changed what when

- Compare to runtime

11

Quick Builder

Experion’s configuration

tool for SCADA points &

Equipment templating

Page 12: Experion SCADA and the Long Reach of Control

© 2016 by Honeywell International Inc. All rights reserved.

Display Builder Display Repository & MOC

API 1168 - Inbuilt Management of Change of the HMI

Version control

Check in, check out

Supports API 1168

Recommended Practice for

Pipeline Control Room

Management

12

HMIWeb Display

Builder

Experion’s configuration

tool for HMI Displays

Page 13: Experion SCADA and the Long Reach of Control

© 2016 by Honeywell International Inc. All rights reserved.

New types:“Scanned – Analog”“Scanned – Status”

Config for this parameter

Use case: Motor Status

Use case: Flag arrays

Use case: PLC PID Loop

User Defined Parameters: Scanned

Do more with less: Keep related data together

13

Page 14: Experion SCADA and the Long Reach of Control

© 2016 by Honeywell International Inc. All rights reserved.

Example Use Case: PLC PID Loops

PLC Configuration Options such as PID Tuning

14

User defined

scanned

parameters on an

Analog point

Page 15: Experion SCADA and the Long Reach of Control

© 2016 by Honeywell International Inc. All rights reserved.

RTU2020 Integration - System Status

Same diagnostics as accessed in RTU Builder

15

RTU2020

specific tabs

Data direct from

RTU2020

Page 16: Experion SCADA and the Long Reach of Control

© 2016 by Honeywell International Inc. All rights reserved.

RTU2020 Integration - Config Efficiency

16

Experion Quick Builder

DNP3 Controller

RTU Builder

Project

Page 17: Experion SCADA and the Long Reach of Control

© 2016 by Honeywell International Inc. All rights reserved.

RTU2020 Integration - Config Efficiency

Converts RTU2020 Project into Experion Points & maintains it

17

Page 18: Experion SCADA and the Long Reach of Control

© 2016 by Honeywell International Inc. All rights reserved.

RTU2020 Integration – Meter Runs

Preconfigured RTU2020 EFM Templates in Experion

18

Page 19: Experion SCADA and the Long Reach of Control

© 2016 by Honeywell International Inc. All rights reserved.

3rd Party Package Integration

Reduce time and effort for PLC point configuration

19

PLC ProgramCreate

SpreadsheetCreate points Test points

Create

pointsTest points

Create

TemplatesPLC Program

As-Is Workflow

To-Be Workflow

Project

Vendor

Software

For Allen-Bradley

ControlLogix on

Ethernet/IP

Page 20: Experion SCADA and the Long Reach of Control

© 2016 by Honeywell International Inc. All rights reserved.

3rd Party Package “Updates” Workflow

Reduce time and effort for point update and validation

20

Update PLC ProgramUpdate

SpreadsheetUpdate points Validate points

Update

pointsTest pointsUpdate PLC Program

Validate

points

Test points

Project

Vendor

Software

As-Is Workflow

To-Be Workflow

Page 21: Experion SCADA and the Long Reach of Control

© 2016 by Honeywell International Inc. All rights reserved.

3rd Party Package - Config Efficiency

21

Experion Quick Builder

Controller

ControlLogix

Project

Page 22: Experion SCADA and the Long Reach of Control

© 2016 by Honeywell International Inc. All rights reserved.

Operational Application Suite Enhancements

Integrated, low up keep solution

Addition of Liquid Pipeline Apps

- Leak Detection

- Batch Tracking

- Linepack

Comply to standards:- API 21.2

liquids measurement

- API 1130 & API 1149

leak detection

22

Pipeline Route Segment Node Flow Calc

Page 23: Experion SCADA and the Long Reach of Control

© 2016 by Honeywell International Inc. All rights reserved.

What’s New for SCADA in R500

• Backup Control Center

• Management of Change: Points &

Displays

• New SCADA Protocols for EFMs

• SCADA Point User Defined Scanned

Parameters

• RTU2020 Integration

• Third Party Package Configuration

Efficiency

• Liquid Pipeline Applications

23

R500

Page 24: Experion SCADA and the Long Reach of Control

© 2016 by Honeywell International Inc. All rights reserved.

Experion SCADA

24

HMI Design Alarm Management Distributed System Architecture

Virtualization Solutions Radically Simplified Configuration Superior Operator Experience

Page 25: Experion SCADA and the Long Reach of Control

© 2016 by Honeywell International Inc. All rights reserved.

25

www.honeywellprocess.com