Experimental Plan
Click here to load reader
description
Transcript of Experimental Plan
CHF in Cation Exchange for Water Softening: Performance and Equipment Design
General Statement of the Problem: If coconut husk fiber (CHF) in ion exchange is to have its industrial applications, a thorough research should be done to improve the performance and reduce the cost of the CHF ion exchange set-up.
Plant Design Objective(s)
Experimental Objective(s)
Parametersto be Measured
Facilities Requirements Schedule
1.To determine the characteristics of the
CHF cation exchanger
I. To determine the CHF’s percent solids through the determination of the loss of mass at 104.62’C for 18 hours
Mass, g
Equipment or Apparatuses:Balance, weighing vessels, oven, dessicator, thong, asbestos mat
Materials and Supplies:Coconut husk fiber(CHF)
June 25-30, 2007
II. To determine the CHF’s adsorption isotherm by exposing CHF to increasingly higher concentrations of Ca2+ allowing contact to reach equilibrium
Mass, gConcentration,
(mg/L)
Equipment or Apparatuses:Erlenmeyer flask, balance, volumetric flasks, beaker, weighing vessel, stopper, stirring rod, buret, funnel, filter paper, dessicator
MaterialsCHF,CaCO3,Na2H2EDTA.2H2O,distilled and deioinized water,NH3,NH4Cl,Eriochrome Black T indicator triethanolamine
July 2-21, 2007
III. To determine the rate constant for the rate of CHF’s cation exchange using a constantly-stirred
Concentration, (mg/L)
Contact time, min
Equipment or Apparatuses: CSTR, buret ,pipet, beakers, Erlenmeyer flasks, volumetric flasks, timer/stopwatch, dropper
July 16-August 18,2007
reactor (CSTR)
Materials: CHF,CaCO3,MgCO3,NA2H2EDTA.2H2Odistilled and deionized water, NH3, NH4Cl, Eriochrome black T indicator, triethanolamine, NaOH, hydroxylnaphthol blue indicator
2.To determine the values for the CHF cation exchanger’s design parameters
I. To determine the service time and minimum bed depth of the CHF cation exchanger systems through the breakthrough experiment
Concentration (mg/L)
Contact time, (min)
Column area,m2
Height, mFlow rate, (m3/min)
Equipment or Apparatuses:Glass column(or 1L/500-mL buret),50-mL burets, pipet, beakers, volumetric flasks, timer/stopwatch, flowmeter
Materials:CHF, CaCO3 ,Na2H2EDTA.2H2O, distilled and deionized water, NH3, NH4Cl, Eriochrome black T indicator, triethanolamine, hose, ruler and gravel
August 20-September 8,2007
3.To describe the comparability of the CHF cation exchanger with the commercial ion exchanger
I. To compare the performance of CHF and commercial ion exchanger in terms of effluent pH, turbidity, color and amount of hardness removed
pHconcentration,
(mg/L)color
Turbidity
Equipment or Apparatuses: pH meter, buret, beakers, Erlenmeyer flasks, volumetric flasks, pipet, timer/stopwatch, flow meter
Materials:CHF, CaCO3, Na2H2EDTA.2H2O, distilled and deionized water, NH3, NH4Cl, Eriochrome black T indicator, triethanolamine
November 26-December 13, 2007