Existing Data
-
Upload
nghiemta18 -
Category
Documents
-
view
217 -
download
0
description
Transcript of Existing Data
![Page 1: Existing Data](https://reader036.fdocuments.in/reader036/viewer/2022082714/5695d0d51a28ab9b02940fc7/html5/thumbnails/1.jpg)
H-31 Existing Design Data
Heater Type Cabin StylePermitted Firing Capacity 175 MMBTU/hrNumber of Burners 32Burner Manufacturer/Model/Type John Zink PSMR-15, Low NOx Burner (LNB)Forced Draft (FD) Fan N/AInduced Draft (ID) Fan N/AAir Preheater N/AFlue Gas Recirculation (FGR) N/ASelective Catalytic Removal (SCR) Unit N/AStack Waste Heat Economizer BFW Economizer
H-32 Existing Design Data
Heater Type Cabin StylePermitted Firing Capacity 175 MMBTU/hrNumber of Burners 32Burner Manufacturer/Model/Type John Zink PSMR-15, Low NOx Burner (LNB)Forced Draft (FD) Fan N/AInduced Draft (ID) Fan N/AAir Preheater N/AFlue Gas Recirculation (FGR) N/ASelective Catalytic Removal (SCR) Unit N/AStack Waste Heat Economizer BFW Economizer
H-33 Existing Design Data
Heater Type Cabin StylePermitted Firing Capacity 153.6 MMBTU/hrNumber of Burners 32Burner Manufacturer/Model/Type John Zink MA 16 WB, Low NOx Burner (LNB)Forced Draft (FD) Fan N/AInduced Draft (ID) Fan N/AAir Preheater N/AFlue Gas Recirculation (FGR) N/ASelective Catalytic Removal (SCR) Unit N/AStack Waste Heat Economizer BFW Economizer
H-34 Existing Design Data
Heater Type Cabin StylePermitted Firing Capacity 153.6 MMBTU/hrNumber of Burners 32Burner Manufacturer/Model/Type John Zink, Low NOx Burner (LNB)Forced Draft (FD) Fan N/AInduced Draft (ID) Fan N/AAir Preheater N/AFlue Gas Recirculation (FGR) N/ASelective Catalytic Removal (SCR) Unit N/AStack Waste Heat Economizer BFW Economizer
![Page 2: Existing Data](https://reader036.fdocuments.in/reader036/viewer/2022082714/5695d0d51a28ab9b02940fc7/html5/thumbnails/2.jpg)
DU-255 Existing Design Data
Heater Type Cabin Style with Air PreheaterPermitted Firing Capacity 350 MMBTU/hrNumber of Burners 36Burner Manufacturer/Model/Type Callidus LE-CSG-10W, Low NOx Burner (LNB)Forced Draft (FD) Fan One, 70,000 ACFM @ 5.5” H2O, 100 HPInduced Draft (ID) Fan One, 40,602 CFM, 125 HPAir Preheater YesFlue Gas Recirculation (FGR) N/ASelective Catalytic Removal (SCR) Unit N/AStack Waste Heat Economizer No
Boiler 6 Existing Design Data
Heater Type Cabin Style with FGRPermitted Firing Capacity 250 MMBTU/hrNumber of Burners 2Burner Manufacturer/Model/Type Coen CRF/FGR-30, Low NOx Burner (LNB)Forced Draft (FD) Fan One, 41,900 SCFM, 300 HPInduced Draft (ID) Fan One, 18,170 ACFM @ 30” H2O, 125 HPAir Preheater N/AFlue Gas Recirculation (FGR) YesSelective Catalytic Removal (SCR) Unit N/AStack Waste Heat Economizer BFW Economizer
Boiler 8 Existing Design Data
Heater Type Cabin Style with FGRPermitted Firing Capacity 179 MMBTU/hrNumber of Burners 1Burner Manufacturer/Model/Type Coen CPF/FGR-37.5, Low NOx Burner (LNB)Forced Draft (FD) Fan One, 36,446 CFM @ 20.92” H2O, 350 HPInduced Draft (ID) Fan One, 11,550 ACFM @ 18” H2O, 50 HPAir Preheater N/AFlue Gas Recirculation (FGR) YesSelective Catalytic Removal (SCR) Unit N/AStack Waste Heat Economizer BFW Economizer