NEW TAPERED INSULATION SYSTEM NEW COVERBOARD NEW MODIFIED BITUMEN ROOF SYSTEM NEW BASE FLASHINGS NEW TERMINATION BAR NEW COUNTERFLASHING EXISTING BRICK EXISTING CONDITIONS EXISTING CONDITIONS NEW CLEAT NEW GRAVEL STOP EXISTING WOOD BLOCKING NEW INSULATION NEW COVERBOARD NEW MODIFIED BITUMEN ROOF SYSTEM EXISTING CONDITIONS EXISTING CONDITIONS EXISTING CONDITIONS EXISTING CONDITIONS EXISTING CONCRETE PANELS 2 6 NEW WOOD BLOCKING NEW INSULATION NEW DRAIN SUMP NEW LEAD FLASHING NEW MODIFIED BITUMEN ROOF SYSTEM NEW PRIMARY DRAIN ASSEMBLY NEW DECKING TO MATCH EXISTING. NEW FASTENERS NEW 4-BAND NO-HUB CLAMP NEW INSULATION NEW LEAD FLASHING NEW MODIFIED BITUMEN ROOF SYSTEM NEW OVERFLOW DRAIN ASSEMBLY NEW DECKING TO MATCH EXISTING. NEW FASTENERS NEW 4-BAND NO-HUB CLAMP NEW INSULATION NEW COVERBOARD NEW MODIFIED BITUMEN ROOF SYSTEM NEW BASE FLASHINGS NEW COUNTERFLASHING EXISTING CURB COVER EXISTING CONDITIONS EXISTING CONDITIONS EXISTING CONDITIONS 2 10 NEW INSULATION NEW COVERBOARD NEW MODIFIED BITUMEN ROOF SYSTEM NEW BASE FLASHINGS NEW COPING NEW PVC SHEATHING NEW WOOD BLOCKING NEW TAPERED WOOD FIBER NEW TERMINATION BAR NEW COUNTERFLASHING EXISTING CONDITIONS EXISTING CONDITIONS EXISTING BRICK NEW FLASHINGS NEW INSULATION NEW COVERBOARD NEW MODIFIED BITUMEN ROOF SYSTEM NEW BASE FLASHINGS NEW COPING NEW PVC SHEATHING NEW TAPERED WOOD FIBER EXISTING WOOD BLOCKING EXISTING CONDITIONS EXISTING CONDITIONS EXISTING CONDITIONS EXISTING CONCRETE PANELS EXISTING FASCIA EXTENSION EXISTING EXPANSION JOINT COVER AREA B (N.I.C.) NEW INSULATION NEW COVERBOARD NEW MODIFIED BITUMEN ROOF SYSTEM NEW BASE FLASHINGS 2 8 2 NEW COPING NEW PVC SHEATHING NEW CLEAT NEW FASCIA EXTENSION WITH BREAK NEW STUD WALL NEW PLYWOOD NEW PLYWOOD 8 EXISTING CONDITIONS EXISTING CONDITIONS EXISTING CONDITIONS EXISTING CONDITIONS NEW STUD WALL NEW TAPERED WOOD FIBER NEW CLEAT NEW FASCIA EXTENSION WITH BREAK NEW COUNTERFLASHING EXISTING EIFS EXISTING CONDITIONS EXISTING CONDITIONS EXISTING CONDITIONS EXISTING CONDITIONS NEW INSULATION NEW COVERBOARD NEW MODIFIED BITUMEN ROOF SYSTEM NEW BASE FLASHINGS 2 8 2 NEW COPING NEW PVC SHEATHING NEW CLEAT NEW FASCIA EXTENSION WITH BREAK NEW STUD WALL NEW PLYWOOD NEW PLYWOOD 8 NEW STUD WALL NEW TAPERED WOOD FIBER NEW HVAC UNIT SEE PLAN NEW INSULATION NEW COVERBOARD NEW MODIFIED BITUMEN ROOF SYSTEM NEW BASE FLASHINGS NEW VERTICAL INSULATION NEW COVERBOARD NEW WOOD BLOCKING NEW COUNTERFLASHING NEW HSS STUB COLUMN NEW MC STEEL NEW MC STEEL EXISTING CONDITIONS EXISTING CONDITIONS NEW ROOF DECK 5" OF ISOCYANURATE INSULATION HVAC & ROOF EXCHANGE UPGRADE 1 8 9 5 4 7 TYP. PARAPET DETAIL - AREA A TYP. PARAPET DETAIL - AREA A TYP. CURB DETAIL TYP. PRIMARY ROOF DRAIN - AREA A TYP. GRAVEL STOP DETAIL - AREA A TYP. OVERFLOW ROOF DRAIN - AREA A 2 6 3 TYP. STUD WALL WITH FASCIA EXTENSION - AREA C TYP. ROOF TO WALL TRANSITION DETAIL - AREA C TYP. AREA C AND AREA B JUNCTURE DETAIL 10 TYP. NEW UNIT CURB FLASHING DETAIL

Transcript of EXCHANGE HVAC & ROOF UPGRADE ARB Ex...20 MIL PVC SHEATHING SMACNA ARCHITECTURAL SHEET METAL DETAIL...

Page 1: EXCHANGE HVAC & ROOF UPGRADE ARB Ex...20 MIL PVC SHEATHING SMACNA ARCHITECTURAL SHEET METAL DETAIL DRIVE CLEAT DETAIL SMACNA ARCHITECTURAL SHEET METAL DETAIL FORMED METAL COPING DETAIL

NEW TAPERED INSULATION SYSTEM

NEW COVERBOARD

NEW MODIFIED BITUMEN ROOF SYSTEM

NEW BASE FLASHINGS

NEW TERMINATION BAR

NEW COUNTERFLASHING

EXISTING BRICK

EXISTING CONDITIONSEXISTING CONDITIONS

NEW CLEAT

NEW GRAVEL STOP

EXISTING WOOD BLOCKING

NEW INSULATION

NEW COVERBOARD

NEW MODIFIED BITUMEN ROOF SYSTEM

EXISTING CONDITIONSEXISTING CONDITIONSEXISTING CONDITIONSEXISTING CONDITIONS

EXISTING CONCRETE PANELS

2 6

NEW WOOD BLOCKING

NEW INSULATION

NEW DRAIN SUMP

NEW LEAD FLASHING

NEW MODIFIED BITUMEN ROOF SYSTEM

NEW PRIMARY DRAIN ASSEMBLY

NEW DECKING TO MATCH EXISTING.

NEW FASTENERS

NEW 4-BAND NO-HUB CLAMP

NEW INSULATION

NEW LEAD FLASHING

NEW MODIFIED BITUMEN ROOF SYSTEM

NEW OVERFLOW DRAIN ASSEMBLY

NEW DECKING TO MATCH EXISTING.

NEW FASTENERS

NEW 4-BAND NO-HUB CLAMP

NEW INSULATION

NEW COVERBOARD

NEW MODIFIED BITUMEN ROOF SYSTEM

NEW BASE FLASHINGS

NEW COUNTERFLASHING

EXISTING CURB COVER

EXISTING CONDITIONSEXISTING CONDITIONSEXISTING CONDITIONS

2 10

NEW INSULATION

NEW COVERBOARD

NEW MODIFIED BITUMEN ROOF SYSTEM

NEW BASE FLASHINGS

NEW COPING

NEW PVC SHEATHING

NEW WOOD BLOCKING

NEW TAPERED WOOD FIBER

NEW TERMINATION BAR

NEW COUNTERFLASHING

EXISTING CONDITIONSEXISTING CONDITIONS

EXISTING BRICK

NEW FLASHINGS

NEW INSULATION

NEW COVERBOARD

NEW MODIFIED BITUMEN ROOF SYSTEM

NEW BASE FLASHINGS

NEW COPING

NEW PVC SHEATHING

NEW TAPERED WOOD FIBER

EXISTING WOOD BLOCKING

EXISTING CONDITIONSEXISTING CONDITIONSEXISTING CONDITIONS

EXISTING CONCRETE PANELS

EXISTING FASCIA EXTENSION

EXISTING EXPANSION

JOINT COVER

AREA B (N.I.C.)

NEW INSULATION

NEW COVERBOARD

NEW MODIFIED BITUMEN ROOF SYSTEM

NEW BASE FLASHINGS

2 8

2

NEW COPING

NEW PVC SHEATHING

NEW CLEAT

NEW FASCIA EXTENSION

WITH BREAK

NEW STUD WALL

NEW PLYWOOD

NEW PLYWOOD

8

EXISTING CONDITIONSEXISTING CONDITIONSEXISTING CONDITIONSEXISTING CONDITIONS

NEW STUD WALL

NEW TAPERED WOOD FIBER

NEW CLEAT

NEW FASCIA EXTENSION

WITH BREAK

NEW COUNTERFLASHING

EXISTING EIFS

EXISTING CONDITIONSEXISTING CONDITIONSEXISTING CONDITIONSEXISTING CONDITIONS

NEW INSULATION

NEW COVERBOARD

NEW MODIFIED BITUMEN ROOF SYSTEM

NEW BASE FLASHINGS

2 8

2

NEW COPING

NEW PVC SHEATHING

NEW CLEAT

NEW FASCIA EXTENSION

WITH BREAK

NEW STUD WALL

NEW PLYWOOD

NEW PLYWOOD

8

NEW STUD WALL

NEW TAPERED WOOD FIBER

NEW HVAC UNIT

SEE PLAN

NEW INSULATION

NEW COVERBOARD

NEW MODIFIED BITUMEN ROOF SYSTEM

NEW BASE FLASHINGS

NEW VERTICAL INSULATION

NEW COVERBOARD

NEW WOOD BLOCKING

NEW COUNTERFLASHING

NEW HSS STUB COLUMN

NEW MC STEELNEW MC STEEL

EXISTING CONDITIONSEXISTING CONDITIONS

NEW ROOF DECK

5" OF ISOCYANURATE

INSULATION

HVAC & ROOF

EXCHANGE

UPGRADE

1

8 9

54

7

TYP. PARAPET DETAIL - AREA ATYP. PARAPET DETAIL - AREA A

TYP. CURB DETAIL TYP. PRIMARY ROOF DRAIN - AREA A

TYP. GRAVEL STOP DETAIL - AREA A

TYP. OVERFLOW ROOF DRAIN - AREA A

2

6

3

TYP. STUD WALL WITH FASCIA EXTENSION - AREA C

TYP. ROOF TO WALL TRANSITION DETAIL - AREA C

TYP. AREA C AND AREA B JUNCTURE DETAIL

10

TYP. NEW UNIT CURB FLASHING DETAIL

Page 2: EXCHANGE HVAC & ROOF UPGRADE ARB Ex...20 MIL PVC SHEATHING SMACNA ARCHITECTURAL SHEET METAL DETAIL DRIVE CLEAT DETAIL SMACNA ARCHITECTURAL SHEET METAL DETAIL FORMED METAL COPING DETAIL

2 8

2 8

NEW INSULATION

NEW COVERBOARD

NEW MODIFIED BITUMEN ROOF SYSTEM

NEW BASE FLASHINGS

NEW COPING

NEW PVC SHEATHING

NEW STUD WALL

NEW TAPERED WOOD FIBER

NEW CLEAT

NEW FASCIA EXTENSION

NEW STUD WALL

NEW PLYWOOD

EXISTING CONDITIONSEXISTING CONDITIONSEXISTING CONDITIONS

EXISTING CONCRETE PANEL

EXISTING DRAIN ASSEMBLY

WITH NEW STATIC EXTENTION

NEW ALUMINUM DOME STRAINER AND

CLAMPING RING

NEW INSULATION

NEW COVERBOARD

NEW LEAD FLASHING

NEW MODIFIED BITUMEN ROOF SYSTEM

NEW 1 INCH/FOOT DRAIN SUMP

EXISTING DRAIN

EXISTING FRAMING

NEW INSULATION

NEW COVERBOARD

NEW MODIFIED BITUMEN ROOF SYSTEM

NEW BASE FLASHINGS

NEW SEALANT

NEW COUNTERFLASHING

NEW TERMINATION BAR

EXISTING CONDITIONSEXISTING CONDITIONSEXISTING CONDITIONS

NEW INSULATION

NEW COVERBOARD

NEW MODIFIED BITUMEN ROOF SYSTEM

NEW SCUPPER LINER

NEW PLYWOOD, THICKNESS AS REQUIRED

NEW CONDUCTOR HEAD

NEW STUD WALL BEYOND

EXISTING CONDITIONSEXISTING CONDITIONSEXISTING CONDITIONS

NEW COVERBOARD

NEW BASE FLASHINGS

NEW COPING

NEW PVC SHEATHING

EXISTING WOOD BLOCKING

NEW TAPERED INSULATION SYSTEM

NEW MODIFIED BITUMEN ROOF SYSTEM

NEW TAPERED WOOD FIBER

EXISTING CONDITIONSEXISTING CONDITIONSEXISTING CONDITIONS

EXISTING CONCRETE PANEL

EXISTING DRAIN ASSEMBLY.

REFER TO SPECIFICATION.

NEW LEAD FLASHING.

REFER TO SPECIFICATION.

NEW MODIFIED BITUMEN

ROOFING SYSTEM.

REFER TO SPECIFICATION.

NEW DRAIN SUMP.

REFER TO SPECIFICATION.

EXISTING DECKING.

HVAC & ROOF

EXCHANGE

UPGRADE

1

TYP. NEW STUD WALL DETAIL - CANOPY A

2

TYP. CHANNEL SCUPPER DETAIL - CANOPIES A & C

3

TYP. ROOF TO WALL TRANSITION DETAIL

4

TYP. DRAIN DETAIL - CANOPY

5

TYP. PARAPET DETAIL

6

TYP. DRAIN DETAIL - AREA C

Page 3: EXCHANGE HVAC & ROOF UPGRADE ARB Ex...20 MIL PVC SHEATHING SMACNA ARCHITECTURAL SHEET METAL DETAIL DRIVE CLEAT DETAIL SMACNA ARCHITECTURAL SHEET METAL DETAIL FORMED METAL COPING DETAIL

NEW COPING

NEW

GRAVEL-STOP

REFER TO

SPECIFICATION.

NEW METAL CANT

STRIP CLOSURE.

NEW MEMBRANE

FLASHING.

NEW STUD WALL

EXISTING CONCRETE

WALL PANELS

NEW CONTINUOUS UNDERLAYMENT

NEW SCUPPER LINER

NEW COPING AND CLOSURE

NEW FASCIA

EXTENSION

CONDUCTOR HEAD

NOT SHOWN FOR

CLARITY

FLASHING BENT INSIDE VENT

ALTERNATE TWO PIECE FLASHING

12"

SMACNA ARCHITECTURAL

SHEET METAL MANUAL

SOIL PIPE VENT DETAIL

TWO APPLICATIONS OF

LIQUID FLASHING.

REFER TO SPECIFICATION.

MESH FABRIC BETWEEN TWO

APPLICATIONS LIQUID FLASHING.

REFER TO SPECIFICATION.

NEW ROOFING.

REFER TO SPECIFICATION.

TWO APPLICATIONS OF

LIQUID FLASHING.

REFER TO SPECIFICATION.

NEW DECKING TO MATCH EXISTING

NEW FASTENERS

EXISTING DECKING

EXISTING BEAM OR SUPPORT

NEW DECKING TO MATCH EXISTING

NEW FASTENERS

EXISTING DECKING

EXISTING BEAM OR SUPPORT

NEW 24 GA. GALVANIZED

STEEL W/KYNAR FINISH

COUNTERFLASHING.

REFER TO SPECIFICATION

NEW 0.040" THICK ALUMINUM W/

KYNAR 500 FINISH OR EQUAL

COPING CLOSURE @ JUNCTURE

OF WALL ABOVE ROOF LEVEL.

REFER TO SPECIFICATION

EXISTING PARAPET

COUNTERFLASHING & COPING CLOSURE

INSTALLATION: JUNCTURE OF COPING

AND WALL ABOVE ROOF LEVEL

20 MIL PVC

SHEATHING

SMACNA ARCHITECTURAL

SHEET METAL DETAIL

DRIVE CLEAT DETAIL

SMACNA ARCHITECTURAL SHEET

METAL DETAIL

FORMED METAL COPING DETAIL

NEW STEEL PLATE

EXISTING SUPPORT

NEW FASTENER

EXISTING DECKING

HVAC & ROOF

EXCHANGE

UPGRADE

1

3

4

2

65

CANT STRIP CLOSURE DETAIL

TYP. PIPE FLASHING

TYP. COPING TERMINATION AT WALL DETAIL

TYP. SMALL METAL DECK OPENING CLOSURETYP. LARGE METAL DECK OPENING CLOSURE

CHANNEL SCUPPER FLASHING DETAIL

Page 4: EXCHANGE HVAC & ROOF UPGRADE ARB Ex...20 MIL PVC SHEATHING SMACNA ARCHITECTURAL SHEET METAL DETAIL DRIVE CLEAT DETAIL SMACNA ARCHITECTURAL SHEET METAL DETAIL FORMED METAL COPING DETAIL

ZONE NO. 1 ZONE NO. 2 ZONE NO. 3

6"

1' 2' 2'

6"

1'-6"

6" 6" 1'1'-6"

6"

6"

6"

1' 1' 1' 1' 1' 1' 1'6"

6"

1'

1'

1'

6"

ZONE NO. 1 ZONE NO. 2 ZONE NO. 3

1'-6"

1'

1'

2'

1' 2' 1'

6"

6"

6"

6"

6" 6"6"

6"

1' 1' 1' 6"

6"

1'

1'

1'

6"

1'2' 1'6"6"1'-6" 1'

1'

6"

6"

1'

1' 1'

6"

1'

1'

1' 4"

4"

4"

4"

4"

4"

4"

4"1' 6" 6"

4"

1'

4"

6" 4"

4"

4" 4"

1'

4"6"4"

HVAC & ROOF

EXCHANGE

UPGRADE

1

TYP. ADHERED INSULATION

TYP. MECHANICALLY ATTACHED INSULATION

2