Excellent AM-PC Model Instructions

download Excellent AM-PC Model Instructions

of 4

Transcript of Excellent AM-PC Model Instructions

  • 8/14/2019 Excellent AM-PC Model Instructions

    1/4

    EXCELLENTAM-PCCREDIT CARD SECURITY SAFEInstal la tio n

    Instr uct ions IMPORTANT

    Remove serial number tag from back of

    cabinet and record serial number.

    Keep keys in a secure place away from children.

    For electronic safes- DO NOT STORE KEYS INSIDE SAFE

    SELECTING A LOCATIONYour security safe should be installed in an isolated, dry and secure area.

    For greater security the safe must be fastened to solid surfaces. Ideally the safe would be installed

    to both a wall and permanent shelf.

    SECURING THE SAFESecure the safe to the wall and permanent shelf using the holes and hardware provided.

    Mark the holes to be used. Drill the appropriate diameter and depth of pilot holes depending on

    the type of hardware being used and the type of mounting surface. Source the safe with the

    fasteners.

    NOTE: The safe needs to be upright and right side up or the locking mechanism wont work.

    POWER SUPPLY

    I. BatteryThe working voltage for the product is equal to 4 1.5v 5# alkaline batteries.

    Warning: Batteries of any other specification or rechargeable batteries are prohibited for

    use, or the electronic system will fail or even the mechanism inside will be burned.

    II. Test battery energyPress the locking key #, and the battery energy test procedure will start. If the display reads

    BA-HI, it means the batteries are normal; if the display reads BA-LO, it means the batteries

    are low and must be replaced as soon as possible.

    III. Replace batteries1. Pull the door open the make sure the power switch is in the O (off) state.2. Use a hex screwdriver and ring screwdriver to remove the two screws from the back

    cover. Pull out the back cover and you will see the battery compartment.

    3. Take out the old batteries and replace them with 4 fresh batteries by lining them up in amanner as indicated by the + and -signs.

    4. Apply the back cover and secure it with screws.

    5. Turn on the power and press until it is in the I (on) state, and now it is ready to work.

    IV. Cautions on battery use1. When replacing batteries, remember to replace all the batteries at once and never use old

    and fresh batteries together.

    2. Never break up the batteries, or it may cause short circuit.

    3. Never dispose off the batteries to fire or similar high-temperature mediums.

    4. Never mix the specified batteries with over types of batteries in use.

    CODE SYSTEMThe product uses three code systemsOne system is the personal code system;

    Another is the personal credit card system;Still another is the emergency code system;

    Notes: the back-up personal code for the product on delivery from manufacturer is 1234,

    and the back-up emergency code 011223.

    WarningFor the purpose of security, the user should change the back-up personal code and emergency

    code prior to use and as soon as he or she purchases the product. Or the company shall not be

    responsible for any theft caused by such negligence.

    Key #:________________________

    Serial #:______________________

    Electronic Safe

    Combination __________________

  • 8/14/2019 Excellent AM-PC Model Instructions

    2/4

    Tips1. The personal code is a code system that may be set at 3 to 6 digits. The product on

    delivery comes with a present 4-digits code system. If you wish to use 3-digit, 5-digit or

    6-digit code system, you may contact the service center or local distributor who shallprovide related assistance.

    2. The emergency code system is a code system that may be set at 6 to 12 digits.

    NoteIn this manual, the illustration for personal code system is based on the 4-digit code systemand the illustration for emergency code system is based on the 6-digit code system.

    PERSONAL CODE SYSTEM

    I. Set the personal code1. Open the door with the back-up personal code 1234 or the emergency code 011223.

    Caution: Ensure the door is at open position (that is, the locking bolts retract),

    otherwise you will not be able to set a new code.

    2. Key in a 4-digits combination that you desire, and the display shall flash the

    corresponding digits; then press the LOCK (#) key to actuate automatic extension of

    the locking bolts, and the display shall read CLOSE and subsequently flash the four

    digits you entered just now for 0.5 seconds. At this point, you have completed the setting

    of 4-digits personal code.

    (Note: We have used 2345 as example for 4-digit personal code. You may choose your

    own 4-digit combination for security.)

    II. Open with the personal codeKey in the previously set 4-digit combination while the display flashes the digits entered. The

    display shall then read OPENED as the bolts retract automatically. Now pull the door knob

    lightly, and the door opens. (Note: We used 2345as example for 4-digits personal code in code

    setting, therefore the code for opening should be 2345 here.)

    III. Close with the personal code1. Close the door and key in the 4-digit combination that you have set, the display will read

    the digits you entered.

    2. Press the LOCK (#) key, and the display will read CLOSE as the locking bolts

    extend.

    3. When the door is safely locked, the display will again read the 4 digits you have just

    entered, which will disappear after a few seconds. Notes: Each time you lock the door,

    you will need enter the user code and then press the LOCK (#) key. Such design is forsecurity purpose.

    PERSONAL CREDIT CARD SYSTEM

    I. Close with personal credit cardClose the door and make sure the door is unlocked. Place the card flat against the slot (magnetic

    strip down) and pass the card from right to left through the slot quickly and in even speed. The

    display will subsequently read CLOSE as the locking bolts extend. Now the door is safely

    locked.

    II. Open with personal credit cardUse the same credit card as above (accessible only to the same card for opening) and pass the card

    from right to left through the slot in the same way as above. The display will subsequently read

    OPENED as the locking bolts retract. Now the door can be easily opened.

    Note: The card reader system is designed to have high safety features and be accessible to the one

    and same card only. This means you must use the same card for locking and unlocking of the safe.

    TipsOnce you select to use the personal credit card system, you will not be able to use the 4-digit code

    system, and the vice versa. This means you will have to choose one of these two systems. If you

  • 8/14/2019 Excellent AM-PC Model Instructions

    3/4

    wish to use the two systems together, you may contact the service center or local distributor who

    shall provide assistance in the respect.

    EMERGENCY CODE SYSTEM

    I. Change emergency code1. Reset the system power (push the power switch from I (on) position to O (off)

    position back to I (on) position), and the display will subsequently read SECURE and

    GOOD.2. When GOOD disappears from the display, push the *key twice, and the display, will

    read PROG. Then key in the original emergency code 011223, and the display will

    read NEW.

    3. Key in the any combination of 6 to 12 digits that your desire, the display will read

    AGAIN.

    4. Again key in the emergency code you have just entered (in case of combination of less

    than 12 digits, you will need push the key # for combination), the display will read

    DONE, indicating that you have successfully changed the emergency code.

    Caution: Before changing the emergency code, you have to enter the back-up emergencycode.

    (Note: In the diagram we use 456789 as example for the new emergency code. You may choose

    your own emergency code for security.)

    WarningAlways remember the new emergency code, or you will not be able to change it again.

    II. Emergency useThe emergency code is to be used in time of emergency only. This means you may use this system

    only when you forget your personal code or have lost your personal credit card.

    III. Open with emergency codeKey in the 6-digit emergency code (confirmed to have been changed), and the locking bolts will

    retract. The display will subsequently read OPENED and the door may be easily opened. (Note:

    We have used 456789 as example for the new emergency code, therefore the emergency code

    for opening is also 456789.)

    MOUNTING

    I. Preparations and check before mounting

    1. Determine the location and size for mountinga. Fix the case in a place where it is not easy to remove the ensure security of product.

    b. The product may be either mounted inside a cabinet sitting against a wall or mounted on thefloor with a special-purpose bracket.

    c. Please pay attention to shape and size of the product corresponding to its model.

    2. Compressive strength and surface evenness of the place for mountinga. Fix must check and confirm the bearing load of the location for mounting to avoid any incident.

    b. You must check and surface evenness of wall, cabinet or floor. Any uneven surface may cause

    difficulties in mounting or tripping hazard.

    II. Mounting methodThe product may be mounted by securing either the back or the bottom of the safe. You may

    select the appropriate mounting method considering the varying situation.

    1. Mounting by securing the back of safea. After determining the place for mounting, drill holes for expansion bolts (or clamping screws)

    in the right place.

    b. Use the expansion bolts (or clamping screws) to secure the case to wall.

    c. Make sure the case is mounted in place as required and then tighten all screws.

    Note: Use the expansion bolts when it is a concrete wall surface.

    Use the clamping screw when it is a wooden wall surface.

    2. Mounting by security the bottom safea. After determining the place for mounting. Drill holes for expansion bolts (or clamping screws)

    in the right place.b. Use the clamping screws (or expansion bolts) to secure the case to the floor.

  • 8/14/2019 Excellent AM-PC Model Instructions

    4/4

    c. Make sure the case is mounted in place as required and then tighten all screws.

    Note: Use the clamping screw when it is wooden floor.

    Use the expansion bolt when it is concrete floor.

    TipsIf you need the product to be mounted right on the floor, you may choose to the special- purpose

    bracket supplied as an optionally supplied item. Two types of special-purpose bracket are

    available: triangular bracket. Please contact the service center or local distributor.

    DATA DISPLAYI. Normal data displayAGAIN: (AGAIN) indicates that you need to key in the previously entered digits a second time.

    BA-HI: (BA-HI) indicates that the batteries are normal.

    BA-lo: (BA-LO) indicates that the batteries are low.

    CLOSE: (CLOSE) indicates that the locking bolts are extending automatically.

    CLOSED: (CLOSED) indicates that the locking bolts have extended.

    Done: (DONE) indicates that you have successfully completed the operation.

    New: (NEW) indicates that you have need to key in new digits right now.

    OPEN: (OPEN) indicates the locking bolts are retracing.Opened: (OPENED) indicates that the locking bolts have retracted (you may open the door).

    II. Error data displayWhen the following data appear on the display, it means an operation error has occurred and you

    will need to operate per the following instruction:

    HOLD15: This data appear on the display after you have entered the incorrect code for four times

    in a succession. It means the electronic code system is now locked out and that you will not be

    able to operate the keys until the system unlocks itself in 15 minutes.

    ERROR: This data means you have swipe the credit card or entered the code incorrectly andthat you need to swipe the card or enter the code correctly.

    ERROR1: This data indicates the door fails to open as the bolts get stuck. In this case, give apush to the door to set free the bolts before you perform the opening operation.

    ERROR2: This data indicates the bolt stud is being held (the door may be left unlatched) andlocking bolts fail to extend. In this case, give a push to the door until it firmly fit into place before

    you proceed with closing operation.