Ex-inox-foil - external integral insulation for euro4 and tier 4 atex

3
SALES : Blażej PIKOR ([email protected]) +48 (0) 71 313 59 68 int 233 TECHNICAL: Adam WALCZAK ([email protected]) +48 (0) 71 313 59 68 int 243 INSULATION EXHAUST PIPE FOR SCR AND DPF SYSTEMS FOR EURO 4+ and TIER IV EX-INOX-FOIL ® External integral insulation made from stainless steel foil is an application to EURO 4+ and TIER IV from ATEX Company Integral insulation is required adaptation for DPF and SCR exhaust systems. Following application provide correct burning of exhaust gasses in the filter (about 600°C) This feature allow to increase borderline temperature of exhaust gasses, what is a reason of required level of working and full functionality. Integral insulation is keeping heat inside, or outside (800°C inside and 250°C outside)

description

EX-INOX-FOIL® External integral insulation made from stainless steel foil is an application to EURO 4+ and TIER IV from ATEX Company

Transcript of Ex-inox-foil - external integral insulation for euro4 and tier 4 atex

SALES : Błażej PIKOR ([email protected]) +48 (0) 71 313 59 68 int 233 TECHNICAL: Adam WALCZAK ([email protected]) +48 (0) 71 313 59 68 int 243

INSULATION EXHAUST PIPE FOR SCR AND DPF SYSTEMS FOR EURO 4+ and TIER IV

EX-INOX-FOIL®

External integral insulation made from stainless steel foil is an application to EURO 4+ and TIER

IV from ATEX Company

� Integral insulation is required adaptation for DPF and SCR exhaust systems.

� Following application provide correct burning of exhaust gasses in the filter

(about 600°C)

� This feature allow to increase borderline temperature of exhaust gasses, what

is a reason of required level of working and full functionality.

� Integral insulation is keeping heat inside, or outside (800°C inside and 250°C

outside)

SALES : Błażej PIKOR ([email protected]) +48 (0) 71 313 59 68 int 233 TECHNICAL: Adam WALCZAK ([email protected]) +48 (0) 71 313 59 68 int 243

Example application for off-road machinery:

• Adaptation: SCR or DPF exhaust systems for TIER IV

• Material: Stainless steel pipe: 1.4301 (AISI 304)

• Diameter: 76,1 mm x 2 mm

• CLR: 99,1

• Insulation: glassneedlemat 10mm (up to 550 °C), silicatneedlemats 10mm (up to 1000 °C),

covered with stainless steel foil 1.4828 (AISI 309)

• Application: 550 °C or 1000 °C

• Test: Assuming that ambient temperature is 20°C and medium is about 550°C considering air

flow 1 m/s temperature of the outer surface is 130°C

• Additionally: insulated compensator HUTCHINSON ESPA – LINKEO or WESTFALIA GHT

• Collar end: type DEUTZ

SALES : Błażej PIKOR ([email protected]) +48 (0) 71 313 59 68 int 233 TECHNICAL: Adam WALCZAK ([email protected]) +48 (0) 71 313 59 68 int 243

PHOTO: