eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics...

30
eW Burst Powercore gen2 Architectural and landscape LED spotlight with solid white light

Transcript of eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics...

Page 1: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2Architectural and landscape LED spotlight with solid white light

Page 2: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide2

eW Burst Powercore gen2Architectural and landscape LED spotlight with solid white light

Two VersionseW Burst Powercore gen2 Architectural luminaires feature an integrated yoke with canopy base for mounting to standard US junction boxes or directly to flat surfaces. eW Burst Powercore gen2 Landscape luminaires feature a 1/2 in NPT threaded post for mounting to standard junction boxes and third-party mounting accessories.

• Expands customization with a wide range of new Philips accessory options. In addition to the native 6° lens, six different diffuser lenses can customize the luminaire to produce 10°, 20°, 40°, 60°, 80°, and 10° x 40° (asymmetric) beam angles. Four housing color choices (black, gray, white, and bronze)—plus the option to add a louver, full glare shield, half glare shield, and an architectural mounting arm designed for use on buildings—create new aesthetic possibilities for designers and architects.

• Meets ASTM G85 corrosion resistance and ANSI C136.31-2010 standard with a 3G vibration rating.

• Integrates patented Powercore technology that controls power output to luminaires directly from line voltage – rapidly, efficiently, and accurately. The Philips Color Kinetics Data Enabler Pro merges line voltage with control data and delivers them to luminaires over a single standard cable, dramatically simplifying installation and lowering total system cost.

• Improves durability with new flat lens that prevents water from pooling into the luminaire, keeping the LEDs protected and secure over the course of a luminaire’s lifetime.

• Universal power input range of 100 to 277 VAC.

• Precision Dimming—Smooth dimming down to 1% with optional Data Enabler Pro and digital control interface.

• Works seamlessly with the Philips Color Kinetics full range of controllers, including Light System Manager, Video System Manager, Video System Manager Pro, iPlayer 3, Antumbra Color Keypad, and ColorDial Pro—as well as third-party controllers.

eW Burst Powercore gen2 is a high-output, exterior-rated LED lighting luminaire designed for accent and site lighting. Architectural and Landscape versions deliver high-quality white light output in 2700 K, 3000 K, 3500 K, and 4000 K to support a range of uplighting, floodlighting, and decorative lighting applications.

Page 3: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide 3

PhotometricsPhotometric data is based on test results from an independent NIST traceable testing lab. IES data is available at www.colorkinetics.com/support/ies.

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

5,686 fc

1,422 fc

632 fc

355 fc

228 fc

158 fc

0.5 ft

0.9 ft

1.4 ft

1.9 ft

2.3 ft

2.7 ft

0.5 ft

0.9 ft

1.4 ft

1.9 ft

2.3 ft

2.7 ft

�� Horiz. Spread: 6.5º�� Vert. Spread: 6.5º91.8 m (301 ft)

1 fc maximum distance

Illuminance at DistanceeW Burst Powercore gen22700 K, 6° native lens 0 25 45 65 90

0 90974 90974 90974 90974 909745 22915 22915 22915 22915 2291515 567 567 567 567 56725 82 82 82 82 8235 0 0 0 0 045 0 0 0 0 055 0 0 0 0 065 0 0 0 0 075 0 0 0 0 085 0 0 0 0 090 0 0 0 0 0

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.001.16 1.15 1.13 1.12 1.14 1.13 1.12 1.00 1.09 1.08 1.07 1.05 1.05 1.04 1.02 1.01 1.01 0.991.14 1.12 1.09 1.08 1.12 1.10 1.08 0.99 1.07 1.06 1.04 1.04 1.03 1.02 1.02 1.01 1.00 0.991.12 1.09 1.07 1.05 1.11 1.08 1.06 0.99 1.05 1.04 1.02 1.03 1.02 1.01 1.01 1.00 0.99 0.981.10 1.07 1.04 1.02 1.09 1.06 1.04 0.98 1.04 1.02 1.01 1.03 1.01 1.00 1.01 1.00 0.99 0.981.09 1.05 1.03 1.01 1.08 1.05 1.02 0.98 1.03 1.01 1.00 1.02 1.00 0.99 1.01 0.99 0.98 0.971.08 1.04 1.01 1.00 1.07 1.03 1.01 0.97 1.02 1.00 0.99 1.01 0.99 0.98 1.00 0.99 0.98 0.971.07 1.03 1.00 0.98 1.06 1.02 1.00 0.97 1.01 0.99 0.98 1.00 0.99 0.97 1.00 0.98 0.97 0.961.06 1.02 0.99 0.98 1.05 1.01 0.99 0.96 1.01 0.99 0.97 1.00 0.98 0.97 0.99 0.98 0.97 0.961.05 1.01 0.99 0.97 1.04 1.01 0.98 0.96 1.00 0.98 0.97 0.99 0.98 0.96 0.99 0.97 0.96 0.961.04 1.00 0.98 0.96 1.03 1.00 0.98 0.96 0.99 0.97 0.96 0.99 0.97 0.96 0.98 0.97 0.96 0.95

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 1949.3 99.9%0-40 1950.4 100.0%0-60 1950.4 100.0%60-90 0.0 0.0%70-100 0.0 0.0%90-120 0.0 0.0%0-90 1950.4 100.0%90-180 0.0 0.0%0-180 1950.4 100.0%

Zonal Lumen

Cd: 0

15,167

30,333

45,500

60,667

75,833

91,000

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Lumens Efficacy CRI1,851 64.7 81

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

2,846 fc

711 fc

316 fc

178 fc

114 fc

79 fc

.6 ft

1.2 ft

1.8 ft

2.4 ft

3.0 ft

3.6 ft

.6 ft

1.2 ft

1.8 ft

2.4 ft

3.0 ft

3.6 ft

�� Horiz. Spread: 8.6º�� Vert. Spread: 8.6º64.9 m (213 ft)

1 fc maximum distance

Illuminance at DistanceeW Burst Powercore gen22700 K, 10° diffuser lens 0 25 45 70 90

0 45530 45530 45530 45530 455305 18101 18101 18101 18101 1810115 691 691 691 691 69125 152 152 152 152 15235 54 54 54 54 5445 30 30 30 30 3055 12 12 12 12 1265 0 0 0 0 075 0 0 0 0 085 0 0 0 0 090 0 0 0 0 0

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.001.16 1.14 1.13 1.11 1.14 1.12 1.11 0.99 1.08 1.07 1.06 1.05 1.04 1.03 1.01 1.01 1.00 0.991.13 1.10 1.08 1.06 1.11 1.09 1.07 0.97 1.06 1.04 1.03 1.03 1.02 1.00 1.00 0.99 0.98 0.971.11 1.07 1.04 1.02 1.09 1.06 1.03 0.96 1.04 1.02 1.00 1.01 1.00 0.98 0.99 0.98 0.97 0.961.09 1.05 1.02 0.99 1.07 1.04 1.01 0.95 1.02 0.99 0.98 1.00 0.98 0.97 0.98 0.97 0.96 0.951.07 1.02 0.99 0.97 1.05 1.02 0.99 0.94 1.00 0.98 0.96 0.99 0.97 0.95 0.97 0.96 0.94 0.931.05 1.00 0.97 0.95 1.04 1.00 0.97 0.93 0.99 0.96 0.94 0.97 0.95 0.94 0.96 0.95 0.93 0.921.03 0.99 0.96 0.94 1.02 0.98 0.95 0.92 0.97 0.95 0.93 0.96 0.94 0.93 0.96 0.94 0.92 0.911.02 0.97 0.94 0.92 1.01 0.97 0.94 0.91 0.96 0.94 0.92 0.95 0.93 0.92 0.95 0.93 0.91 0.911.01 0.96 0.93 0.91 1.00 0.96 0.93 0.90 0.95 0.93 0.91 0.94 0.92 0.91 0.94 0.92 0.91 0.900.99 0.95 0.92 0.90 0.99 0.95 0.92 0.90 0.94 0.92 0.90 0.94 0.91 0.90 0.93 0.91 0.90 0.89

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 1562.5 95.7%0-40 1597.1 97.8%0-60 1630.8 99.9%60-90 2.4 0.1%70-100 0.0 0.0%90-120 0.0 0.0%0-90 1633.3 100.0%90-180 0.0 0.0%0-180 1633.3 100.0%

Zonal Lumen

Cd: 0

7,667

15,333

23,000

30,667

38,333

46,000V

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Lumens Efficacy CRI1,605 55.8 82

Page 4: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide4

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

752 fc

188 fc

84 fc

47 fc

30 fc

21 fc

1.3 ft

2.6 ft

3.9 ft

5.2 ft

6.5 ft

7.8 ft

1.3 ft

2.7 ft

4.0 ft

5.4 ft

6.7 ft

8.1 ft

�� Horiz. Spread: 19.1º�� Vert. Spread: 18.5º33.4 m (109.5 ft)

1 fc maximum distance

eW Burst Powercore gen2 2700 K, 20° diffuser lens 0 25 45 65 90

0 12032 12032 12032 12032 120325 10613 10388 10164 9948 962215 2333 2118 2022 1933 180325 274 264 254 250 23335 67 64 63 63 5845 30 30 31 26 2855 18 21 17 13 1465 8 8 7 8 875 4 4 5 4 385 2 0 0 2 090 0 2 0 0 0

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.001.15 1.13 1.11 1.10 1.13 1.11 1.10 0.97 1.07 1.06 1.05 1.04 1.03 1.02 1.00 0.99 0.99 0.971.12 1.08 1.06 1.03 1.10 1.07 1.04 0.95 1.04 1.02 1.00 1.01 0.99 0.98 0.98 0.97 0.96 0.941.09 1.04 1.01 0.98 1.07 1.03 1.00 0.92 1.01 0.98 0.96 0.98 0.96 0.94 0.96 0.95 0.93 0.921.06 1.01 0.97 0.94 1.04 1.00 0.96 0.90 0.98 0.95 0.93 0.96 0.94 0.92 0.94 0.92 0.91 0.891.03 0.98 0.94 0.91 1.02 0.97 0.93 0.88 0.95 0.92 0.90 0.94 0.91 0.89 0.92 0.90 0.88 0.871.00 0.95 0.91 0.88 0.99 0.94 0.91 0.86 0.93 0.90 0.87 0.92 0.89 0.87 0.90 0.88 0.86 0.850.98 0.92 0.88 0.86 0.97 0.92 0.88 0.84 0.91 0.88 0.85 0.90 0.87 0.85 0.89 0.86 0.84 0.840.96 0.90 0.86 0.84 0.95 0.90 0.86 0.83 0.89 0.86 0.83 0.88 0.85 0.83 0.87 0.85 0.83 0.820.94 0.88 0.84 0.82 0.93 0.88 0.84 0.81 0.87 0.84 0.81 0.86 0.83 0.81 0.85 0.83 0.81 0.800.92 0.86 0.82 0.80 0.91 0.86 0.82 0.79 0.85 0.82 0.80 0.84 0.82 0.80 0.84 0.81 0.80 0.79

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 1551.5 94.4%0-40 1595.8 97.1%0-60 1632.3 99.4%60-90 10.3 0.6%70-100 4.0 0.2%90-120 0.1 0.0%0-90 1642.7 100.0%90-180 0.1 0.0%0-180 1642.7 100.0%

Zonal Lumen

Cd: 0

2,167

4,333

6,500

8,667

10,833

13,000

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Illuminance at Distance

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

193 fc

48 fc

22 fc

12 fc

8 fc

5 fc

2.9 ft

5.8 ft

8.6 ft

11.5 ft

14.4 ft

17.3 ft

2.7 ft

5.4 ft

8.1 ft

10.9 ft

13.6 ft

16.3 ft

�� Horiz. Spread: 37.5º�� Vert. Spread: 39.6º16.9 m (55.5 ft)

1 fc maximum distance

Illuminance at DistanceeW Burst Powercore gen22700 K, 40° diffuser lens 0 25 45 65 90

0 3092 3092 3092 3092 30925 2905 2880 2880 2883 290315 1984 1924 1898 1891 193825 986 941 910 901 92535 340 328 316 305 30745 92 91 88 84 8155 34 33 32 31 2965 17 17 16 14 1275 8 8 7 6 485 2 2 2 1 090 1 1 0 0 0

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.001.14 1.11 1.09 1.07 1.11 1.09 1.07 0.94 1.05 1.03 1.02 1.01 1.00 0.99 0.98 0.97 0.96 0.941.09 1.04 1.00 0.97 1.06 1.02 0.99 0.89 0.99 0.96 0.94 0.96 0.94 0.92 0.93 0.92 0.90 0.881.04 0.98 0.93 0.90 1.02 0.96 0.92 0.84 0.94 0.90 0.87 0.91 0.89 0.86 0.89 0.87 0.85 0.830.99 0.92 0.87 0.83 0.97 0.91 0.86 0.79 0.89 0.85 0.82 0.87 0.84 0.81 0.85 0.82 0.80 0.780.95 0.87 0.82 0.78 0.93 0.86 0.81 0.75 0.85 0.80 0.77 0.83 0.79 0.76 0.81 0.78 0.76 0.740.91 0.83 0.77 0.73 0.89 0.82 0.77 0.71 0.80 0.76 0.73 0.79 0.75 0.72 0.78 0.74 0.72 0.700.87 0.79 0.73 0.69 0.86 0.78 0.73 0.68 0.77 0.72 0.69 0.75 0.71 0.68 0.74 0.71 0.68 0.670.83 0.75 0.69 0.66 0.82 0.74 0.69 0.65 0.73 0.69 0.65 0.72 0.68 0.65 0.71 0.67 0.65 0.630.80 0.71 0.66 0.62 0.79 0.71 0.66 0.62 0.70 0.65 0.62 0.69 0.65 0.62 0.68 0.64 0.62 0.600.77 0.68 0.63 0.59 0.76 0.68 0.63 0.59 0.67 0.62 0.59 0.66 0.62 0.59 0.65 0.62 0.59 0.58

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 1266.5 80.4%0-40 1461.9 92.8%0-60 1552.5 98.5%60-90 18.6 1.2%70-100 6.0 0.4%90-120 0.7 0.0%0-90 1571.1 99.7%90-180 4.4 0.3%0-180 1575.5 100.0%

Zonal Lumen

Cd: 0

533

1,067

1,600

2,133

2,667

3,200

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Lumens Efficacy CRI1,601 55.6 82

Lumens Efficacy CRI1,583 55.2 82

Page 5: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide 5

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

101 fc

25 fc

11 fc

6 fc

4 fc

3 fc

4.6 ft

9.2 ft

13.7 ft

18.3 ft

22.9 ft

27.5 ft

4.6 ft

9.1 ft

13.7 ft

18.3 ft

22.8 ft

27.4

�� Horiz. Spread: 59.4º�� Vert. Spread: 59.6º12.3 m (40.2 ft)

1 fc maximum distance

Illuminance at DistanceeW Burst Powercore gen22700 K, 60° diffuser lens 0 25 45 65 90

0 1616 1616 1616 1616 16165 1578 1576 1577 1584 159315 1348 1335 1346 1364 140025 982 977 977 992 102635 558 537 529 535 55145 200 189 185 185 18755 59 57 54 52 4965 24 23 22 20 1875 12 11 10 8 685 3 2 2 1 090 1 1 1 1 0

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.001.13 1.10 1.07 1.05 1.11 1.08 1.06 0.93 1.04 1.02 1.00 1.00 0.99 0.97 0.97 0.95 0.94 0.931.07 1.02 0.97 0.94 1.05 1.00 0.96 0.86 0.97 0.93 0.91 0.94 0.91 0.89 0.91 0.89 0.87 0.851.01 0.94 0.89 0.85 0.99 0.93 0.88 0.79 0.90 0.86 0.82 0.88 0.84 0.81 0.85 0.82 0.80 0.780.95 0.87 0.81 0.77 0.94 0.86 0.81 0.73 0.84 0.79 0.76 0.82 0.78 0.75 0.80 0.77 0.74 0.720.90 0.81 0.75 0.70 0.89 0.80 0.74 0.68 0.78 0.73 0.69 0.77 0.72 0.69 0.75 0.71 0.68 0.670.85 0.76 0.69 0.65 0.84 0.75 0.69 0.63 0.73 0.68 0.64 0.72 0.67 0.64 0.71 0.67 0.63 0.620.81 0.71 0.65 0.60 0.79 0.70 0.64 0.59 0.69 0.63 0.60 0.68 0.63 0.59 0.67 0.62 0.59 0.570.77 0.67 0.60 0.56 0.75 0.66 0.60 0.55 0.65 0.59 0.55 0.64 0.59 0.55 0.63 0.58 0.55 0.530.73 0.63 0.56 0.52 0.72 0.62 0.56 0.51 0.61 0.56 0.52 0.60 0.55 0.52 0.59 0.55 0.51 0.500.69 0.59 0.53 0.49 0.68 0.58 0.53 0.48 0.58 0.52 0.49 0.57 0.52 0.48 0.56 0.52 0.48 0.47

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 1013.7 63.6%0-40 1365.2 85.6%0-60 1567.4 98.3%60-90 27.5 1.7%70-100 8.5 0.5%90-120 0.0 0.0%0-90 1594.8 100.0%90-180 0.0 0.0%0-180 1594.9 100.0%

Zonal Lumen

Cd: 0

283

587

850

1,133

1,417

1,700

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

67 fc

17 fc

7 fc

4 fc

3 fc

2 fc

5.9 ft

11.7 ft

17.6 ft

23.4 ft

29.3 ft

35.2 ft

6.0 ft

12.0 ft

18.0 ft

24.0 ft

30.0 ft

36.0 ft

�� Horiz. Spread: 73.8º�� Vert. Spread: 72.4º10 m (32.8 ft)

1 fc maximum distance

Illuminance at DistanceeW Burst Powercore gen22700 K, 80° diffuser lens 0 25 45 65 90

0 1071 1071 1071 1071 10715 1058 1065 1070 1078 108215 1010 1029 1046 1064 108525 904 924 947 966 98835 648 657 664 672 67645 312 310 307 301 28955 101 98 94 90 8065 34 32 31 28 2475 15 14 12 10 885 4 3 3 2 190 2 2 1 1 0

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.001.13 1.09 1.06 1.04 1.10 1.07 1.05 0.92 1.03 1.01 0.99 0.99 0.98 0.96 0.96 0.95 0.93 0.911.06 1.00 0.95 0.91 1.03 0.98 0.94 0.84 0.95 0.91 0.88 0.92 0.89 0.87 0.89 0.87 0.85 0.830.99 0.92 0.86 0.81 0.97 0.90 0.85 0.76 0.88 0.83 0.79 0.85 0.81 0.78 0.83 0.80 0.77 0.750.93 0.84 0.78 0.73 0.91 0.83 0.77 0.69 0.81 0.76 0.72 0.79 0.74 0.71 0.77 0.73 0.70 0.680.87 0.78 0.71 0.66 0.86 0.77 0.70 0.63 0.75 0.69 0.65 0.73 0.68 0.64 0.71 0.67 0.64 0.620.82 0.72 0.65 0.60 0.80 0.71 0.64 0.58 0.69 0.64 0.59 0.68 0.63 0.59 0.66 0.62 0.58 0.570.77 0.66 0.60 0.55 0.76 0.66 0.59 0.53 0.64 0.59 0.54 0.63 0.58 0.54 0.62 0.57 0.54 0.520.73 0.62 0.55 0.50 0.71 0.61 0.55 0.49 0.60 0.54 0.50 0.59 0.54 0.50 0.58 0.53 0.49 0.480.69 0.58 0.51 0.46 0.67 0.57 0.51 0.46 0.56 0.50 0.46 0.55 0.50 0.46 0.54 0.49 0.46 0.440.65 0.54 0.47 0.43 0.64 0.53 0.47 0.42 0.52 0.47 0.43 0.52 0.46 0.42 0.51 0.46 0.42 0.41

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 822.5 52.9%0-40 1219.4 78.5%0-60 1518.7 97.7%60-90 35.4 2.3%70-100 10.1 0.7%90-120 0.0 0.0%0-90 1554.1 100.0%90-180 0.0 0.0%0-180 1554.1 100.0%

Zonal Lumen

Cd: 0

200

400

600

800

1,000

1,200

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Lumens Efficacy CRI1,586 55.1 82

Lumens Efficacy CRI1,562 54.4 82

Page 6: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide6

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

779 fc

195 fc

87 fc

49 fc

31 fc

22 fc

.5 ft

1.1 ft

1.6 ft

2.1 ft

2.7 ft

3.2 ft

3.0 ft

6.0 ft

8.9 ft

11.9 ft

14.9 ft

17.9

�� Horiz. Spread: 40.9º�� Vert. Spread: 7.6º34 m (111.5 ft)

1 fc maximum distance

eW Burst Powercore gen2 2700 K, 10° x 40° asymmetric lens 0 25 45 70 90

0 12460 12460 12460 12460 124605 3968 4784 6419 10160 1220915 324 389 649 2975 888225 87 115 189 641 416335 40 46 66 174 112945 23 25 32 64 19055 9 13 18 28 5665 4 7 10 12 2575 2 3 4 4 1085 1 2 2 2 190 1 2 1 1 1

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 0.99 1.11 1.11 1.11 1.06 1.06 1.06 1.01 1.01 1.01 0.991.14 1.12 1.10 1.08 1.12 1.10 1.08 0.95 1.06 1.04 1.03 1.02 1.01 1.00 0.98 0.98 0.97 0.951.10 1.06 1.03 1.00 1.08 1.04 1.01 0.92 1.01 0.99 0.97 0.98 0.96 0.95 0.95 0.94 0.93 0.911.06 1.01 0.97 0.94 1.04 1.00 0.96 0.88 0.97 0.94 0.92 0.95 0.92 0.90 0.92 0.90 0.89 0.871.02 0.97 0.92 0.89 1.01 0.95 0.91 0.85 0.93 0.90 0.87 0.91 0.89 0.86 0.90 0.87 0.85 0.840.99 0.93 0.88 0.85 0.98 0.92 0.87 0.82 0.90 0.86 0.84 0.88 0.85 0.83 0.87 0.84 0.82 0.810.96 0.89 0.84 0.81 0.94 0.88 0.84 0.79 0.87 0.83 0.80 0.85 0.82 0.80 0.84 0.81 0.79 0.780.93 0.86 0.81 0.78 0.92 0.85 0.81 0.76 0.84 0.80 0.77 0.83 0.79 0.77 0.82 0.79 0.76 0.750.90 0.83 0.78 0.75 0.89 0.82 0.78 0.74 0.81 0.77 0.75 0.80 0.77 0.74 0.79 0.76 0.74 0.730.87 0.80 0.76 0.73 0.86 0.80 0.75 0.72 0.79 0.75 0.72 0.78 0.75 0.72 0.77 0.74 0.72 0.710.85 0.78 0.73 0.70 0.84 0.77 0.73 0.70 0.77 0.73 0.70 0.76 0.72 0.70 0.75 0.72 0.70 0.69

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 1423.5 87.5%0-40 1538.1 94.5%0-60 1598.3 98.2%60-90 16.5 1.0%70-100 8.4 0.5%90-120 4.7 0.3%0-90 1614.8 99.2%90-180 12.7 0.8%0-180 1627.5 100.0%

Zonal Lumen

Cd: 0

2,167

4,333

6,500

8,667

10,833

13,000

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Illuminance at Distance

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

5,686 fc

1,422 fc

632 fc

355 fc

227 fc

158 fc

0.5 ft

0.9 ft

1.4 ft

1.8 ft

2.3 ft

2.7 ft

0.5 ft

0.9 ft

1.4 ft

1.8 ft

2.3 ft

2.7 ft

�� Horiz. Spread: 6.5º�� Vert. Spread: 6.5º 91.8 m (301 ft)

1 fc maximum distance

Illuminance at DistanceeW Burst Powercore gen23000 K, 6° native lens 0 25 45 70 90

0 147505 147505 147505 147505 1475055 37784 39504 40048 41107 4179315 660 662 725 664 63025 0 0 0 0 035 0 0 0 0 045 0 0 0 0 055 0 0 0 0 065 0 0 0 0 075 0 0 0 0 085 0 0 0 0 090 0 0 0 0 0

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.001.16 1.15 1.13 1.12 1.14 1.13 1.12 1.00 1.09 1.08 1.07 1.05 1.05 1.04 1.02 1.01 1.01 0.991.14 1.12 1.09 1.08 1.12 1.10 1.08 0.99 1.07 1.06 1.04 1.04 1.03 1.02 1.02 1.01 1.00 0.991.12 1.09 1.07 1.05 1.11 1.08 1.06 0.99 1.05 1.04 1.02 1.03 1.02 1.01 1.01 1.00 0.99 0.981.10 1.07 1.04 1.02 1.09 1.06 1.04 0.98 1.04 1.02 1.01 1.03 1.01 1.00 1.01 1.00 0.99 0.981.09 1.05 1.03 1.01 1.08 1.05 1.02 0.98 1.03 1.01 1.00 1.02 1.00 0.99 1.01 0.99 0.98 0.971.08 1.04 1.01 1.00 1.07 1.03 1.01 0.97 1.02 1.00 0.99 1.01 0.99 0.98 1.00 0.99 0.98 0.971.07 1.03 1.00 0.98 1.06 1.02 1.00 0.97 1.01 0.99 0.98 1.00 0.99 0.97 1.00 0.98 0.97 0.961.06 1.02 0.99 0.98 1.05 1.01 0.99 0.96 1.01 0.99 0.97 1.00 0.98 0.97 0.99 0.98 0.97 0.961.05 1.01 0.99 0.97 1.04 1.01 0.98 0.96 1.00 0.98 0.97 0.99 0.98 0.96 0.99 0.97 0.96 0.961.04 1.00 0.98 0.96 1.03 1.00 0.98 0.96 0.99 0.97 0.96 0.99 0.97 0.96 0.98 0.97 0.96 0.95

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 1949.3 99.9%0-40 1950.4 100.0%0-60 1950.4 100.0%60-90 0.0 0.0%70-100 0.0 0.0%90-120 0.0 0.0%0-90 1950.4 100.0%90-180 0.0 0.0%0-180 1950.4 100.0%

Zonal Lumen

Cd: 0

15,176

30,333

45,500

60,667

758,833

91,000

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Lumens Efficacy CRI1,616 56.3 82

Lumens Efficacy CRI1,890 66 83

Page 7: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide 7

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

2,846 fc

711 fc

316 fc

178 fc

114 fc

79 fc

0.6 ft

1.2 ft

1.8 ft

2.4 ft

3.0 ft

3.6 ft

0.6 ft

1.2 ft

1.8 ft

2.4 ft

3.0 ft

3.6 ft

�� Horiz. Spread: 8.6º�� Vert. Spread: 8.6º 65 m (213 ft)

1 fc maximum distance

Illuminance at DistanceeW Burst Powercore gen23000 K, 10° diffuser lens 0 25 45 70 90

0 45530 45530 45530 45530 455305 18101 18101 18101 18101 1810115 691 691 691 691 69125 152 152 152 152 15235 54 54 54 54 5445 30 30 30 30 3055 12 12 12 12 1265 0 0 0 0 075 0 0 0 0 085 0 0 0 0 090 0 0 0 0 0

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.001.16 1.14 1.13 1.11 1.14 1.12 1.11 0.99 1.08 1.07 1.06 1.05 1.04 1.03 1.01 1.01 1.00 0.991.13 1.10 1.08 1.06 1.11 1.09 1.07 0.97 1.06 1.04 1.03 1.03 1.02 1.00 1.00 0.99 0.98 0.971.11 1.07 1.04 1.02 1.09 1.06 1.03 0.96 1.04 1.02 1.00 1.01 1.00 0.98 0.99 0.98 0.97 0.961.09 1.05 1.02 0.99 1.07 1.04 1.01 0.95 1.02 0.99 0.98 1.00 0.98 0.97 0.98 0.97 0.96 0.951.07 1.02 0.99 0.97 1.05 1.02 0.99 0.94 1.00 0.98 0.96 0.99 0.97 0.95 0.97 0.96 0.94 0.931.05 1.00 0.97 0.95 1.04 1.00 0.97 0.93 0.99 0.96 0.94 0.97 0.95 0.94 0.96 0.95 0.93 0.921.03 0.99 0.96 0.94 1.02 0.98 0.95 0.92 0.97 0.95 0.93 0.96 0.94 0.93 0.96 0.94 0.92 0.911.02 0.97 0.94 0.92 1.01 0.97 0.94 0.91 0.96 0.94 0.92 0.95 0.93 0.92 0.95 0.93 0.91 0.911.01 0.96 0.93 0.91 1.00 0.96 0.93 0.90 0.95 0.93 0.91 0.94 0.92 0.91 0.94 0.92 0.91 0.900.99 0.95 0.92 0.90 0.99 0.95 0.92 0.90 0.94 0.92 0.90 0.94 0.91 0.90 0.93 0.91 0.90 0.89

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 1562.5 95.7%0-40 1597.1 97.8%0-60 1630.8 99.9%60-90 2.4 0.1%70-100 0.0 0.0%90-120 0.0 0.0%0-90 1633.3 100.0%90-180 0.0 0.0%0-180 1633.3 100.0%

Zonal Lumen

Cd: 0

7,667

15,333

23,000

30,667

38,333

46,000

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

752 fc

188 fc

84 fc

47 fc

30 fc

21 fc

1.3 ft

2.6 ft

3.9 ft

5.2 ft

6.5 ft

7.8 ft

1.3 ft

2.7 ft

4.0 ft

5.4 ft

6.7 ft

8.1 ft

�� Horiz. Spread: 19.1º�� Vert. Spread: 18.5º 33.4 m (109.5 ft)

1 fc maximum distance

Illuminance at DistanceeW Burst Powercore gen23000 K, 20° diffuser lens 0 25 45 65 90

0 12032 12032 12032 12032 120325 10613 10388 10164 9948 962215 2333 2118 2022 1933 180325 274 264 254 250 23335 67 64 63 63 5845 30 30 31 26 2855 18 21 17 13 1465 8 8 7 8 875 4 4 5 4 385 2 0 0 2 090 0 2 0 0 0

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.001.15 1.13 1.11 1.10 1.13 1.11 1.10 0.97 1.07 1.06 1.05 1.04 1.03 1.02 1.00 0.99 0.99 0.971.12 1.08 1.06 1.03 1.10 1.07 1.04 0.95 1.04 1.02 1.00 1.01 0.99 0.98 0.98 0.97 0.96 0.941.09 1.04 1.01 0.98 1.07 1.03 1.00 0.92 1.01 0.98 0.96 0.98 0.96 0.94 0.96 0.95 0.93 0.921.06 1.01 0.97 0.94 1.04 1.00 0.96 0.90 0.98 0.95 0.93 0.96 0.94 0.92 0.94 0.92 0.91 0.891.03 0.98 0.94 0.91 1.02 0.97 0.93 0.88 0.95 0.92 0.90 0.94 0.91 0.89 0.92 0.90 0.88 0.871.00 0.95 0.91 0.88 0.99 0.94 0.91 0.86 0.93 0.90 0.87 0.92 0.89 0.87 0.90 0.88 0.86 0.850.98 0.92 0.88 0.86 0.97 0.92 0.88 0.84 0.91 0.88 0.85 0.90 0.87 0.85 0.89 0.86 0.84 0.840.96 0.90 0.86 0.84 0.95 0.90 0.86 0.83 0.89 0.86 0.83 0.88 0.85 0.83 0.87 0.85 0.83 0.820.94 0.88 0.84 0.82 0.93 0.88 0.84 0.81 0.87 0.84 0.81 0.86 0.83 0.81 0.85 0.83 0.81 0.800.92 0.86 0.82 0.80 0.91 0.86 0.82 0.79 0.85 0.82 0.80 0.84 0.82 0.80 0.84 0.81 0.80 0.79

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 1551.5 94.4%0-40 1595.8 97.1%0-60 1632.3 99.4%60-90 10.3 0.6%70-100 4.0 0.2%90-120 0.1 0.0%0-90 1642.7 100.0%90-180 0.1 0.0%0-180 1642.7 100.0%

Zonal Lumen

Cd: 0

2,167

4,333

6,500

8,667

10,833

13,000

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Lumens Efficacy CRI1,672 58.3 83

Lumens Efficacy CRI1,671 58.1 83

Page 8: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide8

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

193 fc

48 fc

22 fc

12 fc

8 fc

5 fc

2.9 ft

5.8 ft

8.6 ft

11.5 ft

14.4 ft

17.3 ft

2.7 ft

5.4 ft

8.1 ft

10.9 ft

13.6 ft

16.3 ft

�� Horiz. Spread: 37.5º�� Vert. Spread: 39.6º 16.9 m (55.5 ft)

1 fc maximum distance

eW Burst Powercore gen2 3000 K, 40° diffuser lens 0 25 45 65 90

0 3092 3092 3092 3092 30925 2905 2880 2880 2883 290315 1984 1924 1898 1891 193825 986 941 910 901 92535 340 328 316 305 30745 92 91 88 84 8155 34 33 32 31 2965 17 17 16 14 1275 8 8 7 6 485 2 2 2 1 090 1 1 0 0 0

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.001.14 1.11 1.09 1.07 1.11 1.09 1.07 0.94 1.05 1.03 1.02 1.01 1.00 0.99 0.98 0.97 0.96 0.941.09 1.04 1.00 0.97 1.06 1.02 0.99 0.89 0.99 0.96 0.94 0.96 0.94 0.92 0.93 0.92 0.90 0.881.04 0.98 0.93 0.90 1.02 0.96 0.92 0.84 0.94 0.90 0.87 0.91 0.89 0.86 0.89 0.87 0.85 0.830.99 0.92 0.87 0.83 0.97 0.91 0.86 0.79 0.89 0.85 0.82 0.87 0.84 0.81 0.85 0.82 0.80 0.780.95 0.87 0.82 0.78 0.93 0.86 0.81 0.75 0.85 0.80 0.77 0.83 0.79 0.76 0.81 0.78 0.76 0.740.91 0.83 0.77 0.73 0.89 0.82 0.77 0.71 0.80 0.76 0.73 0.79 0.75 0.72 0.78 0.74 0.72 0.700.87 0.79 0.73 0.69 0.86 0.78 0.73 0.68 0.77 0.72 0.69 0.75 0.71 0.68 0.74 0.71 0.68 0.670.83 0.75 0.69 0.66 0.82 0.74 0.69 0.65 0.73 0.69 0.65 0.72 0.68 0.65 0.71 0.67 0.65 0.630.80 0.71 0.66 0.62 0.79 0.71 0.66 0.62 0.70 0.65 0.62 0.69 0.65 0.62 0.68 0.64 0.62 0.600.77 0.68 0.63 0.59 0.76 0.68 0.63 0.59 0.67 0.62 0.59 0.66 0.62 0.59 0.65 0.62 0.59 0.58

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 1266.5 80.4%0-40 1461.9 92.8%0-60 1552.5 98.5%60-90 18.6 1.2%70-100 6.0 0.4%90-120 0.7 0.0%0-90 1571.1 99.7%90-180 4.4 0.3%0-180 1575.5 100.0%

Zonal Lumen

Cd: 0

533

1,067

1,600

2,133

2,667

3,200

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Illuminance at Distance

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

101 fc

25 fc

11 fc

6 fc

4 fc

3 fc

4.6 ft

9.2 ft

13.7 ft

18.3 ft

22.9 ft

27.5 ft

4.6 ft

9.1 ft

13.7 ft

18.3 ft

22.8 ft

27.4 ft

�� Horiz. Spread: 59.4º�� Vert. Spread: 59.6º 12.3 m (40.2 ft)

1 fc maximum distance

Illuminance at DistanceeW Burst Powercore gen23000 K, 60° diffuser lens 0 25 45 65 90

0 1616 1616 1616 1616 16165 1578 1576 1577 1584 159315 1348 1335 1346 1364 140025 982 977 977 992 102635 558 537 529 535 55145 200 189 185 185 18755 59 57 54 52 4965 24 23 22 20 1875 12 11 10 8 685 3 2 2 1 090 1 1 1 1 0

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.001.13 1.10 1.07 1.05 1.11 1.08 1.06 0.93 1.04 1.02 1.00 1.00 0.99 0.97 0.97 0.95 0.94 0.931.07 1.02 0.97 0.94 1.05 1.00 0.96 0.86 0.97 0.93 0.91 0.94 0.91 0.89 0.91 0.89 0.87 0.851.01 0.94 0.89 0.85 0.99 0.93 0.88 0.79 0.90 0.86 0.82 0.88 0.84 0.81 0.85 0.82 0.80 0.780.95 0.87 0.81 0.77 0.94 0.86 0.81 0.73 0.84 0.79 0.76 0.82 0.78 0.75 0.80 0.77 0.74 0.720.90 0.81 0.75 0.70 0.89 0.80 0.74 0.68 0.78 0.73 0.69 0.77 0.72 0.69 0.75 0.71 0.68 0.670.85 0.76 0.69 0.65 0.84 0.75 0.69 0.63 0.73 0.68 0.64 0.72 0.67 0.64 0.71 0.67 0.63 0.620.81 0.71 0.65 0.60 0.79 0.70 0.64 0.59 0.69 0.63 0.60 0.68 0.63 0.59 0.67 0.62 0.59 0.570.77 0.67 0.60 0.56 0.75 0.66 0.60 0.55 0.65 0.59 0.55 0.64 0.59 0.55 0.63 0.58 0.55 0.530.73 0.63 0.56 0.52 0.72 0.62 0.56 0.51 0.61 0.56 0.52 0.60 0.55 0.52 0.59 0.55 0.51 0.500.69 0.59 0.53 0.49 0.68 0.58 0.53 0.48 0.58 0.52 0.49 0.57 0.52 0.48 0.56 0.52 0.48 0.47

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 1013.7 63.6%0-40 1365.2 85.6%0-60 1567.4 98.3%60-90 27.5 1.7%70-100 8.5 0.5%90-120 0.0 0.0%0-90 1594.8 100.0%90-180 0.0 0.0%0-180 1594.9 100.0%

Zonal Lumen

Cd: 0

283

567

850

1,122

1,417

1,700

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Lumens Efficacy CRI1,653 57.5 84

Lumens Efficacy CRI1,655 57.6 83

Page 9: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide 9

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

67 fc

17 fc

7 fc

4 fc

3 fc

2 fc

5.9 ft

11.7 ft

17.6 ft

23.4 ft

29.3 ft

35.2 ft

6.0 ft

12.0 ft

18.0 ft

24.0 ft

30.0 ft

36.0 ft

�� Horiz. Spread: 73.8º�� Vert. Spread: 72.4º 10 m (32.7 ft)

1 fc maximum distance

Illuminance at DistanceeW Burst Powercore gen23000 K, 80° diffuser lens 0 25 45 65 90

0 90974 90974 90974 90974 909745 22915 22915 22915 22915 2291515 567 567 567 567 56725 82 82 82 82 8235 0 0 0 0 045 0 0 0 0 055 0 0 0 0 065 0 0 0 0 075 0 0 0 0 085 0 0 0 0 090 0 0 0 0 0

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.001.13 1.09 1.06 1.04 1.10 1.07 1.05 0.92 1.03 1.01 0.99 0.99 0.98 0.96 0.96 0.95 0.93 0.911.06 1.00 0.95 0.91 1.03 0.98 0.94 0.84 0.95 0.91 0.88 0.92 0.89 0.87 0.89 0.87 0.85 0.830.99 0.92 0.86 0.81 0.97 0.90 0.85 0.76 0.88 0.83 0.79 0.85 0.81 0.78 0.83 0.80 0.77 0.750.93 0.84 0.78 0.73 0.91 0.83 0.77 0.69 0.81 0.76 0.72 0.79 0.74 0.71 0.77 0.73 0.70 0.680.87 0.78 0.71 0.66 0.86 0.77 0.70 0.63 0.75 0.69 0.65 0.73 0.68 0.64 0.71 0.67 0.64 0.620.82 0.72 0.65 0.60 0.80 0.71 0.64 0.58 0.69 0.64 0.59 0.68 0.63 0.59 0.66 0.62 0.58 0.570.77 0.66 0.60 0.55 0.76 0.66 0.59 0.53 0.64 0.59 0.54 0.63 0.58 0.54 0.62 0.57 0.54 0.520.73 0.62 0.55 0.50 0.71 0.61 0.55 0.49 0.60 0.54 0.50 0.59 0.54 0.50 0.58 0.53 0.49 0.480.69 0.58 0.51 0.46 0.67 0.57 0.51 0.46 0.56 0.50 0.46 0.55 0.50 0.46 0.54 0.49 0.46 0.440.65 0.54 0.47 0.43 0.64 0.53 0.47 0.42 0.52 0.47 0.43 0.52 0.46 0.42 0.51 0.46 0.42 0.41

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 822.5 52.9%0-40 1219.4 78.5%0-60 1518.7 97.7%60-90 35.4 2.3%70-100 10.1 0.7%90-120 0.0 0.0%0-90 1554.1 100.0%90-180 0.0 0.0%0-180 1554.1 100.0%

Zonal Lumen

Cd: 0

200

400

600

800

1,000

1,200

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

779 fc

195 fc

87 fc

49 fc

31 fc

22 fc

0.5 ft

1.1 ft

1.6 ft

2.1 ft

2.7 ft

3.2 ft

3.0 ft

6.0 ft

8.9 ft

11.9 ft

14.9 ft

17.9 ft

�� Horiz. Spread: 40.9º�� Vert. Spread: 7.6º 34 m (111.5 ft)

1 fc maximum distance

Illuminance at DistanceeW Burst Powercore gen23000 K, 10° x 40° asymmetric lens 0 25 45 70 90

0 12460 12460 12460 12460 124605 3968 4784 6419 10160 1220915 324 389 649 2975 888225 87 115 189 641 416335 40 46 66 174 112945 23 25 32 64 19055 9 13 18 28 5665 4 7 10 12 2575 2 3 4 4 1085 1 2 2 2 190 1 2 1 1 1

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 0.99 1.11 1.11 1.11 1.06 1.06 1.06 1.01 1.01 1.01 0.991.14 1.12 1.10 1.08 1.12 1.10 1.08 0.95 1.06 1.04 1.03 1.02 1.01 1.00 0.98 0.98 0.97 0.951.10 1.06 1.03 1.00 1.08 1.04 1.01 0.92 1.01 0.99 0.97 0.98 0.96 0.95 0.95 0.94 0.93 0.911.06 1.01 0.97 0.94 1.04 1.00 0.96 0.88 0.97 0.94 0.92 0.95 0.92 0.90 0.92 0.90 0.89 0.871.02 0.97 0.92 0.89 1.01 0.95 0.91 0.85 0.93 0.90 0.87 0.91 0.89 0.86 0.90 0.87 0.85 0.840.99 0.93 0.88 0.85 0.98 0.92 0.87 0.82 0.90 0.86 0.84 0.88 0.85 0.83 0.87 0.84 0.82 0.810.96 0.89 0.84 0.81 0.94 0.88 0.84 0.79 0.87 0.83 0.80 0.85 0.82 0.80 0.84 0.81 0.79 0.780.93 0.86 0.81 0.78 0.92 0.85 0.81 0.76 0.84 0.80 0.77 0.83 0.79 0.77 0.82 0.79 0.76 0.750.90 0.83 0.78 0.75 0.89 0.82 0.78 0.74 0.81 0.77 0.75 0.80 0.77 0.74 0.79 0.76 0.74 0.730.87 0.80 0.76 0.73 0.86 0.80 0.75 0.72 0.79 0.75 0.72 0.78 0.75 0.72 0.77 0.74 0.72 0.710.85 0.78 0.73 0.70 0.84 0.77 0.73 0.70 0.77 0.73 0.70 0.76 0.72 0.70 0.75 0.72 0.70 0.69

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 1423.5 87.5%0-40 1538.1 94.5%0-60 1598.3 98.2%60-90 16.5 1.0%70-100 8.4 0.5%90-120 4.7 0.3%0-90 1614.8 99.2%90-180 12.7 0.8%0-180 1627.5 100.0%

Zonal Lumen

Cd: 0

2,167

4,333

6,500

8,667

10,833

13,000

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Lumens Efficacy CRI1,632 56.8 84

Lumens Efficacy CRI1,650 57.5 83

Page 10: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide10

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

6,651 fc

1,663 fc

739 fc

416 fc

266 fc

185 fc

0.4 ft

0.8 ft

1.2 ft

1.6 ft

2.0 ft

2.4 ft

0.4 ft

0.8 ft

1.2 ft

1.6 ft

2.0 ft

2.4 ft

�� Horiz. Spread: 5.8º�� Vert. Spread: 5.8º99.4 m(326 ft)

1 fc maximum distance

eW Burst Powercore gen2 3500 K, 6° native lens 0 25 45 65 90

0 106407 106407 106407 106407 1064075 22236 22236 22236 22236 2223615 553 553 553 553 55325 60 60 60 60 6035 0 0 0 0 045 0 0 0 0 055 0 0 0 0 065 0 0 0 0 075 0 0 0 0 085 0 0 0 0 090 0 0 0 0 0

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.001.16 1.15 1.13 1.12 1.14 1.13 1.12 1.00 1.09 1.08 1.07 1.05 1.05 1.04 1.02 1.01 1.01 0.991.14 1.12 1.10 1.08 1.12 1.10 1.08 0.99 1.07 1.06 1.04 1.04 1.03 1.02 1.02 1.01 1.00 0.991.12 1.09 1.07 1.05 1.11 1.08 1.06 0.99 1.06 1.04 1.02 1.03 1.02 1.01 1.01 1.00 0.99 0.981.11 1.07 1.05 1.03 1.09 1.06 1.04 0.98 1.04 1.02 1.01 1.03 1.01 1.00 1.01 1.00 0.99 0.981.09 1.05 1.03 1.01 1.08 1.05 1.02 0.98 1.03 1.01 1.00 1.02 1.00 0.99 1.01 0.99 0.98 0.971.08 1.04 1.02 1.00 1.07 1.04 1.01 0.97 1.02 1.00 0.99 1.01 1.00 0.98 1.00 0.99 0.98 0.971.07 1.03 1.01 0.99 1.06 1.03 1.00 0.97 1.02 1.00 0.98 1.01 0.99 0.98 1.00 0.98 0.97 0.971.06 1.02 1.00 0.98 1.05 1.02 0.99 0.97 1.01 0.99 0.97 1.00 0.98 0.97 0.99 0.98 0.97 0.961.05 1.01 0.99 0.97 1.04 1.01 0.99 0.96 1.00 0.98 0.97 1.00 0.98 0.97 0.99 0.98 0.96 0.961.04 1.00 0.98 0.97 1.04 1.00 0.98 0.96 1.00 0.98 0.96 0.99 0.97 0.96 0.99 0.97 0.96 0.96

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 1987.2 100.0%0-40 1987.2 100.0%0-60 1987.2 100.0%60-90 0.0 0.0%70-100 0.0 0.0%90-120 0.0 0.0%0-90 1987.2 100.0%90-180 0.0 0.0%0-180 1987.2 100.0%

Zonal Lumen

Cd: 0

17,833

35,667

53,500

71,333

89,167

107,000

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Illuminance at Distance

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

3,006 fc

752 fc

334 fc

188 fc

120 fc

84 fc

0.7 ft

1.3 ft

2.0 ft

2.6 ft

3.3 ft

3.9 ft

0.7 ft

1.3v

2.0 ft

2.6 ft

3.3 ft

3.9 ft

�� Horiz. Spread: 9.3º�� Vert. Spread: 9.3º66.8 m (219 ft)

1 fc maximum distance

Illuminance at DistanceeW Burst Powercore gen23500 K, 10° diffuser lens 0 25 45 70 90

0 48093 48093 48093 48093 480935 21345 21345 21345 21345 2134515 750 750 750 750 75025 149 149 149 149 14935 38 38 38 38 3845 23 23 23 23 2355 2 2 2 2 265 0 0 0 0 075 0 0 0 0 085 0 0 0 0 090 0 0 0 0 0

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.001.16 1.14 1.13 1.12 1.14 1.12 1.11 0.99 1.08 1.07 1.07 1.05 1.04 1.03 1.01 1.01 1.00 0.991.14 1.11 1.09 1.07 1.12 1.09 1.07 0.98 1.06 1.05 1.03 1.03 1.02 1.01 1.01 1.00 0.99 0.981.11 1.08 1.05 1.03 1.10 1.07 1.04 0.97 1.04 1.02 1.01 1.02 1.01 0.99 1.00 0.99 0.98 0.971.09 1.05 1.03 1.00 1.08 1.04 1.02 0.96 1.03 1.00 0.99 1.01 0.99 0.98 0.99 0.98 0.97 0.961.08 1.03 1.01 0.98 1.06 1.03 1.00 0.95 1.01 0.99 0.97 1.00 0.98 0.96 0.98 0.97 0.96 0.951.06 1.02 0.99 0.97 1.05 1.01 0.98 0.94 1.00 0.98 0.96 0.99 0.97 0.95 0.98 0.96 0.95 0.941.05 1.00 0.97 0.95 1.04 1.00 0.97 0.94 0.99 0.96 0.95 0.98 0.96 0.94 0.97 0.95 0.94 0.931.03 0.99 0.96 0.94 1.02 0.98 0.96 0.93 0.98 0.95 0.94 0.97 0.95 0.93 0.96 0.94 0.93 0.921.02 0.98 0.95 0.93 1.01 0.97 0.95 0.92 0.97 0.94 0.93 0.96 0.94 0.93 0.95 0.94 0.92 0.921.01 0.97 0.94 0.92 1.00 0.96 0.94 0.92 0.96 0.94 0.92 0.95 0.93 0.92 0.95 0.93 0.92 0.91

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 1789.7 97.5%0-40 1817.3 99.0%0-60 1834.7 100.0%60-90 0.3 0.0%70-100 0.0 0.0%90-120 0.0 0.0%0-90 1835.0 100.0%90-180 0.0 0.0%0-180 1835.0 100.0%

Zonal Lumen

Cd: 0

8,176

16,333

24,500

32,667

40,833

49,000

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Lumens Efficacy CRI1,919 67.3 82

Lumens Efficacy CRI1,700 59.5 83

Page 11: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide 11

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

793 fc

198 fc

88 fc

50 fc

32 fc

22 fc

1.3 ft

2.7 ft

4.0 ft

5.3 ft

6.7 ft

8.0 ft

1.4 ft

2.7 ft

4.1 ft

5.5 ft

6.9 ft

8.2 ft

�� Horiz. Spread: 19.4º�� Vert. Spread: 19.0º34.3 m (112.5 ft)

1 fc maximum distance

Illuminance at DistanceeW Burst Powercore gen23500 K, 20° diffuser lens 0 25 45 65 90

0 12694 12694 12694 12694 126945 11443 11138 10924 10673 1027815 2598 2408 2291 2159 197725 309 301 290 274 24935 74 73 67 67 6545 34 32 31 31 2955 18 17 16 17 1465 8 11 7 8 675 4 2 5 3 285 0 0 3 2 090 1 4 1 2 2

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 0.99 1.11 1.11 1.11 1.06 1.06 1.06 1.01 1.01 1.01 0.991.15 1.13 1.11 1.10 1.13 1.11 1.09 0.97 1.07 1.05 1.04 1.03 1.02 1.01 0.99 0.99 0.98 0.961.12 1.08 1.05 1.03 1.09 1.06 1.04 0.94 1.03 1.01 0.99 1.00 0.99 0.97 0.98 0.96 0.95 0.941.08 1.04 1.01 0.98 1.07 1.03 1.00 0.92 1.00 0.98 0.95 0.98 0.96 0.94 0.96 0.94 0.92 0.911.05 1.00 0.97 0.94 1.04 0.99 0.96 0.90 0.97 0.94 0.92 0.95 0.93 0.91 0.94 0.92 0.90 0.891.03 0.97 0.93 0.91 1.01 0.96 0.93 0.87 0.95 0.92 0.89 0.93 0.91 0.89 0.92 0.90 0.88 0.871.00 0.94 0.91 0.88 0.99 0.94 0.90 0.86 0.92 0.89 0.87 0.91 0.88 0.86 0.90 0.88 0.86 0.850.98 0.92 0.88 0.85 0.97 0.91 0.88 0.84 0.90 0.87 0.85 0.89 0.86 0.84 0.88 0.86 0.84 0.830.96 0.90 0.86 0.83 0.95 0.89 0.86 0.82 0.88 0.85 0.83 0.87 0.85 0.83 0.87 0.84 0.82 0.810.94 0.88 0.84 0.81 0.93 0.87 0.84 0.80 0.86 0.83 0.81 0.86 0.83 0.81 0.85 0.82 0.81 0.800.92 0.86 0.82 0.80 0.91 0.85 0.82 0.79 0.85 0.82 0.79 0.84 0.81 0.79 0.83 0.81 0.79 0.78

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 1666.0 93.9%0-40 1711.3 96.5%0-60 1749.1 98.6%60-90 12.0 0.7%70-100 6.7 0.4%90-120 4.3 0.2%0-90 1761.1 99.3%90-180 12.4 0.7%0-180 1773.4 100.0%

Zonal Lumen

Cd: 0

2,167

4,333

6,500

8,667

10,833

13,000

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

203 fc

51 fc

23 fc

13 fc

8 fc

6 fc

2.9 ft

5.8 ft

8.8 ft

11.7 ft

14.6 ft

17.5 ft

2.7 ft

5.5 ft

8.2 ft

11.0 ft

13.7 ft

16.5 ft

�� Horiz. Spread: 37.9º�� Vert. Spread: 40.1º17.4 m (57 ft)

1 fc maximum distance

Illuminance at DistanceeW Burst Powercore gen23500 K, 40° diffuser lens 0 25 45 65 90

0 3252 3252 3252 3252 32525 3148 3101 3069 3045 303515 2251 2108 2021 1958 193825 1172 1076 1001 944 91735 429 391 355 322 29845 116 109 99 89 7955 40 38 35 33 3065 19 19 18 15 1375 9 8 8 6 585 2 3 2 2 190 1 0 0 0 0

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.001.14 1.11 1.09 1.07 1.11 1.09 1.07 0.94 1.05 1.03 1.02 1.01 1.00 0.99 0.98 0.97 0.96 0.941.09 1.04 1.00 0.97 1.06 1.02 0.99 0.89 0.99 0.96 0.94 0.96 0.94 0.92 0.93 0.92 0.90 0.881.04 0.98 0.93 0.90 1.02 0.96 0.92 0.84 0.94 0.90 0.87 0.91 0.88 0.86 0.89 0.87 0.85 0.830.99 0.92 0.87 0.83 0.97 0.91 0.86 0.79 0.89 0.85 0.82 0.87 0.83 0.81 0.85 0.82 0.80 0.780.95 0.87 0.82 0.78 0.93 0.86 0.81 0.75 0.84 0.80 0.77 0.83 0.79 0.76 0.81 0.78 0.75 0.740.91 0.83 0.77 0.73 0.89 0.82 0.77 0.71 0.80 0.76 0.72 0.79 0.75 0.72 0.78 0.74 0.71 0.700.87 0.78 0.73 0.69 0.86 0.78 0.73 0.68 0.76 0.72 0.68 0.75 0.71 0.68 0.74 0.71 0.68 0.660.83 0.75 0.69 0.65 0.82 0.74 0.69 0.64 0.73 0.68 0.65 0.72 0.68 0.65 0.71 0.67 0.64 0.630.80 0.71 0.66 0.62 0.79 0.71 0.66 0.61 0.70 0.65 0.62 0.69 0.65 0.62 0.68 0.64 0.61 0.600.77 0.68 0.63 0.59 0.76 0.68 0.63 0.59 0.67 0.62 0.59 0.66 0.62 0.59 0.65 0.61 0.59 0.57

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 1355.9 80.1%0-40 1570.8 92.8%0-60 1668.4 98.6%60-90 20.0 1.2%70-100 6.7 0.4%90-120 0.6 0.0%0-90 1688.5 99.7%90-180 4.3 0.3%0-180 1692.7 100.0%

Zonal Lumen

Cd: 0

550

1,100

1,650

2,200

2,750

3,300

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Lumens Efficacy CRI1,696 59.3 83

Lumens Efficacy CRI1,685 58.9 83

Page 12: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide12

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

106 fc

27 fc

12 fc

7 fc

4 fc

3 fc

4.6 ft

9.2 ft

13.9 ft

18.5 ft

23.1 ft

27.7 ft

4.6 ft

9.2 ft

13.8 ft

18.4 ft

23.0 ft

27.6 ft

�� Horiz. Spread: 59.8º�� Vert. Spread: 60.0º12.6 m (41.2 ft)

1 fc maximum distance

eW Burst Powercore gen2 3500 K, 60° diffuser lens 0 25 45 65 90

0 1702 1702 1702 1702 17025 1664 1662 1666 1673 168215 1434 1428 1434 1454 148225 1063 1056 1062 1075 109835 611 592 587 592 60445 223 213 210 208 20955 65 63 60 58 5565 26 25 24 22 1975 12 12 10 9 785 3 3 2 2 190 2 2 1 0 0

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.001.13 1.10 1.07 1.05 1.10 1.08 1.05 0.93 1.04 1.02 1.00 1.00 0.98 0.97 0.96 0.95 0.94 0.921.07 1.02 0.97 0.94 1.05 1.00 0.96 0.86 0.97 0.93 0.91 0.94 0.91 0.89 0.91 0.89 0.87 0.851.01 0.94 0.89 0.84 0.99 0.93 0.88 0.79 0.90 0.86 0.82 0.87 0.84 0.81 0.85 0.82 0.80 0.780.95 0.87 0.81 0.77 0.94 0.86 0.81 0.73 0.84 0.79 0.75 0.82 0.78 0.75 0.80 0.76 0.74 0.720.90 0.81 0.75 0.70 0.88 0.80 0.74 0.68 0.78 0.73 0.69 0.77 0.72 0.69 0.75 0.71 0.68 0.670.85 0.76 0.69 0.65 0.84 0.75 0.69 0.63 0.73 0.68 0.64 0.72 0.67 0.64 0.71 0.66 0.63 0.620.81 0.71 0.64 0.60 0.79 0.70 0.64 0.59 0.69 0.63 0.59 0.68 0.63 0.59 0.66 0.62 0.59 0.570.77 0.66 0.60 0.56 0.75 0.66 0.60 0.55 0.65 0.59 0.55 0.64 0.59 0.55 0.63 0.58 0.55 0.530.73 0.62 0.56 0.52 0.72 0.62 0.56 0.51 0.61 0.56 0.52 0.60 0.55 0.52 0.59 0.55 0.51 0.500.69 0.59 0.53 0.49 0.68 0.58 0.53 0.48 0.58 0.52 0.48 0.57 0.52 0.48 0.56 0.51 0.48 0.47

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 1074.0 63.5%0-40 1446.9 85.5%0-60 1659.5 98.1%60-90 28.2 1.7%70-100 9.1 0.5%90-120 0.8 0.0%0-90 1687.7 99.8%90-180 4.2 0.2%0-180 1691.9 100.0%

Zonal Lumen

Cd: 0

300

600

900

1,200

1,500

1,800

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Illuminance at Distance

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

71 fc

18 fc

8 fc

4 fc

3 fc

2 fc

6.0 ft

12.0 ft

18.0 ft

23.9 ft

29.9 ft

35.9 ft

6.2 ft

12.3 ft

18.5 ft

24.6 ft

30.8 ft

36.9 ft

�� Horiz. Spread: 75.1º�� Vert. Spread: 73.6º10.2 m (33.6 ft)

1 fc maximum distance

Illuminance at DistanceeW Burst Powercore gen23500 K, 80° diffuser lens 0 25 45 65 90

0 1130 1130 1130 1130 11305 1122 1127 1131 1140 114315 1078 1092 1112 1129 114025 971 985 1001 1015 102435 703 702 700 693 68645 343 329 316 302 28255 111 102 95 87 7565 36 34 32 28 2375 15 14 11 10 785 4 3 2 2 190 1 2 1 1 0

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.001.12 1.09 1.06 1.04 1.10 1.07 1.04 0.92 1.03 1.01 0.99 0.99 0.97 0.96 0.96 0.94 0.93 0.911.06 1.00 0.95 0.91 1.03 0.98 0.94 0.84 0.95 0.91 0.88 0.92 0.89 0.86 0.89 0.87 0.84 0.830.99 0.92 0.86 0.81 0.97 0.90 0.85 0.76 0.87 0.83 0.79 0.85 0.81 0.78 0.83 0.79 0.77 0.750.93 0.84 0.78 0.73 0.91 0.83 0.77 0.69 0.81 0.76 0.71 0.79 0.74 0.71 0.77 0.73 0.70 0.680.87 0.78 0.71 0.66 0.85 0.77 0.70 0.63 0.75 0.69 0.65 0.73 0.68 0.64 0.71 0.67 0.64 0.620.82 0.72 0.65 0.60 0.80 0.71 0.64 0.58 0.69 0.63 0.59 0.68 0.62 0.59 0.66 0.62 0.58 0.560.77 0.66 0.59 0.55 0.76 0.66 0.59 0.53 0.64 0.58 0.54 0.63 0.58 0.54 0.62 0.57 0.53 0.520.73 0.62 0.55 0.50 0.71 0.61 0.54 0.49 0.60 0.54 0.50 0.59 0.53 0.49 0.58 0.53 0.49 0.480.68 0.57 0.51 0.46 0.67 0.57 0.50 0.45 0.56 0.50 0.46 0.55 0.50 0.46 0.54 0.49 0.45 0.440.65 0.54 0.47 0.43 0.64 0.53 0.47 0.42 0.52 0.46 0.42 0.51 0.46 0.42 0.51 0.46 0.42 0.41

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 868.3 52.6%0-40 1289.9 78.1%0-60 1609.3 97.5%60-90 37.7 2.3%70-100 11.2 0.7%90-120 0.9 0.1%0-90 1647.0 99.8%90-180 3.8 0.2%0-180 1650.8 100.0%

Zonal Lumen

Cd: 0

200

400

600

800

1,000

1,200

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Lumens Efficacy CRI1,679 58.9 83

Lumens Efficacy CRI1,654 57.9 83

Page 13: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide 13

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

859 fc

215 fc

96 fc

54 fc

34 fc

24 fc

1.5 ft

1.1 ft

1.6 ft

2.2 ft

2.7 ft

3.3 ft

3.0 ft

6.1 ft

9.1 ft

12.2 ft

15.2 ft

18.3 ft

�� Horiz. Spread: 41.7º�� Vert. Spread: 7.8°35.7 m (117 ft)

1 fc maximum distance

Illuminance at DistanceeW Burst Powercore gen23500 K, 10° x 40° asymmetric lens 0 25 45 65 90

0 13748 13748 13748 13748 137485 4670 5437 7205 10352 1335015 358 409 678 2079 973625 97 123 206 452 476535 42 46 69 145 131245 22 27 33 58 21655 8 12 18 26 5965 3 5 8 12 2975 4 2 3 4 1085 2 1 1 0 390 0 1 1 1 0

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.001.15 1.12 1.10 1.08 1.12 1.10 1.08 0.96 1.06 1.05 1.03 1.02 1.01 1.00 0.99 0.98 0.97 0.951.10 1.06 1.03 1.00 1.08 1.05 1.02 0.92 1.01 0.99 0.97 0.99 0.97 0.95 0.96 0.94 0.93 0.911.06 1.01 0.97 0.94 1.05 1.00 0.96 0.88 0.97 0.94 0.92 0.95 0.93 0.91 0.93 0.91 0.89 0.881.03 0.97 0.93 0.89 1.01 0.96 0.92 0.85 0.94 0.90 0.88 0.92 0.89 0.87 0.90 0.88 0.86 0.840.99 0.93 0.88 0.85 0.98 0.92 0.88 0.82 0.90 0.87 0.84 0.89 0.86 0.83 0.87 0.85 0.83 0.810.96 0.89 0.85 0.82 0.95 0.89 0.84 0.79 0.87 0.83 0.81 0.86 0.83 0.80 0.85 0.82 0.80 0.780.93 0.86 0.82 0.78 0.92 0.85 0.81 0.77 0.84 0.81 0.78 0.83 0.80 0.77 0.82 0.79 0.77 0.760.90 0.83 0.79 0.76 0.89 0.83 0.78 0.74 0.82 0.78 0.75 0.81 0.77 0.75 0.80 0.77 0.75 0.740.88 0.81 0.76 0.73 0.87 0.80 0.76 0.72 0.79 0.75 0.73 0.78 0.75 0.73 0.78 0.75 0.72 0.710.85 0.78 0.74 0.71 0.84 0.78 0.74 0.70 0.77 0.73 0.71 0.76 0.73 0.70 0.76 0.73 0.70 0.69

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 1538.8 88.0%0-40 1662.8 95.1%0-60 1725.7 98.7%60-90 14.9 0.9%70-100 6.3 0.4%90-120 2.6 0.2%0-90 1740.6 99.5%90-180 8.3 0.5%0-180 1748.9 100.0%

Zonal Lumen

Cd: 0

2,333

4,667

7,000

9,333

1,667

14,000

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

6,759 fc

1,690 fc

751 fc

422 fc

270 fc

188 fc

0.4 ft

0.8 ft

1.2 ft

1.6 ft

1.9 ft

2.3 ft

0.4 ft

0.8 ft

1.2 ft

1.6 ft

1.96 ft

2.3 ft

�� Horiz. Spread: 5.6º�� Vert. Spread: 5.6º100.3 m (329 ft)

1 fc maximum distance

Illuminance at DistanceeW Burst Powercore gen24000 K, 6° native lens 0 50 90 130 180

0 108142 108142 108142 108142 1081425 20907 20907 20907 20907 2090715 694 694 694 694 69425 153 153 153 153 15335 59 59 59 59 5945 0 0 0 0 055 0 0 0 0 065 0 0 0 0 075 0 0 0 0 085 0 0 0 0 090 0 0 0 0 0

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.001.16 1.15 1.13 1.12 1.14 1.12 1.11 0.99 1.09 1.08 1.07 1.05 1.04 1.04 1.02 1.01 1.01 0.991.14 1.11 1.09 1.07 1.12 1.09 1.07 0.98 1.06 1.05 1.03 1.04 1.02 1.01 1.01 1.00 0.99 0.981.11 1.08 1.05 1.03 1.10 1.07 1.04 0.97 1.04 1.03 1.01 1.02 1.01 1.00 1.00 0.99 0.98 0.971.10 1.06 1.03 1.01 1.08 1.05 1.02 0.97 1.03 1.01 0.99 1.01 0.99 0.98 1.00 0.98 0.97 0.961.08 1.04 1.01 0.99 1.07 1.03 1.00 0.96 1.02 0.99 0.98 1.00 0.98 0.97 0.99 0.97 0.96 0.951.06 1.02 0.99 0.97 1.05 1.01 0.99 0.95 1.00 0.98 0.96 0.99 0.97 0.96 0.98 0.97 0.95 0.941.05 1.01 0.98 0.96 1.04 1.00 0.98 0.94 0.99 0.97 0.95 0.98 0.96 0.95 0.97 0.96 0.94 0.941.04 0.99 0.97 0.95 1.03 0.99 0.96 0.94 0.98 0.96 0.94 0.97 0.96 0.94 0.97 0.95 0.94 0.931.03 0.98 0.96 0.94 1.02 0.98 0.96 0.93 0.97 0.95 0.94 0.97 0.95 0.93 0.96 0.94 0.93 0.921.01 0.97 0.95 0.93 1.01 0.97 0.95 0.92 0.96 0.94 0.93 0.96 0.94 0.93 0.95 0.94 0.92 0.92

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 1990.2 97.3%0-40 2028.4 99.2%0-60 2045.8 100.0%60-90 0.0 0.0%70-100 0.0 0.0%90-120 0.0 0.0%0-90 2045.8 100.0%90-180 0.0 0.0%0-180 2045.8 100.0%

Zonal Lumen

Cd: 0

18,167

36,333

54,500

72,667

90,833

109,000

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Lumens Efficacy CRI1,670 58.5 83

Lumens Efficacy CRI2,096 74.6 81

Page 14: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide14

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

3,036 fc

759 fc

337 fc

190 fc

121 fc

84 fc

0.6 ft

1.2 ft

1.8 ft

2.4 ft

3.0 ft

3.6 ft

0.6 ft

1.2 ft

1.8 ft

2.4 ft

3.0 ft

3.6 ft

�� Horiz. Spread: 8.7º�� Vert. Spread: 8.7º67 m (220 ft)

1 fc maximum distance

eW Burst Powercore gen2 4000 K, 10° diffuser lens 0 25 45 70 90

0 48577 48577 48577 48577 485775 19814 19814 19814 19814 1981415 813 813 813 813 81325 177 177 177 177 17735 62 62 62 62 6245 35 35 35 35 3555 16 16 16 16 1665 0 0 0 0 075 0 0 0 0 085 0 0 0 0 090 0 0 0 0 0

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.001.16 1.14 1.13 1.11 1.14 1.12 1.11 0.99 1.08 1.07 1.06 1.04 1.04 1.03 1.01 1.01 1.00 0.981.13 1.10 1.08 1.06 1.11 1.09 1.06 0.97 1.05 1.04 1.02 1.03 1.01 1.00 1.00 0.99 0.98 0.971.11 1.07 1.04 1.02 1.09 1.06 1.03 0.96 1.03 1.01 0.99 1.01 0.99 0.98 0.99 0.98 0.97 0.951.08 1.04 1.01 0.99 1.07 1.03 1.00 0.95 1.01 0.99 0.97 1.00 0.98 0.96 0.98 0.96 0.95 0.941.06 1.02 0.99 0.96 1.05 1.01 0.98 0.93 1.00 0.97 0.95 0.98 0.96 0.95 0.97 0.95 0.94 0.931.05 1.00 0.97 0.95 1.03 0.99 0.96 0.92 0.98 0.96 0.94 0.97 0.95 0.93 0.96 0.94 0.93 0.921.03 0.98 0.95 0.93 1.02 0.98 0.95 0.91 0.97 0.94 0.92 0.96 0.94 0.92 0.95 0.93 0.92 0.911.01 0.97 0.94 0.92 1.01 0.96 0.93 0.90 0.95 0.93 0.91 0.95 0.93 0.91 0.94 0.92 0.91 0.901.00 0.95 0.93 0.91 0.99 0.95 0.92 0.90 0.94 0.92 0.90 0.94 0.92 0.90 0.93 0.91 0.90 0.890.99 0.94 0.91 0.90 0.98 0.94 0.91 0.89 0.93 0.91 0.89 0.93 0.91 0.89 0.92 0.90 0.89 0.88

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 1990.2 97.3%0-40 2028.4 99.2%0-60 2045.8 100.0%60-90 0.0 0.0%70-100 0.0 0.0%90-120 0.0 0.0%0-90 2045.8 100.0%90-180 0.0 0.0%0-180 2045.8 100.0%

Zonal Lumen

Cd: 0

8,167

16,333

24,500

32,667

40,833

49,000

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Illuminance at Distance

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

834 fc

209 fc

93 fc

52 fc

33 fc

23 fc

1.3 ft

2.7 ft

4.0 ft

5.3 ft

6.6 ft

8.0 ft

1.4 ft

2.7 ft

4.1 ft

5.4 ft

6.8 ft

8.2 ft

�� Horiz. Spread: 19.3º�� Vert. Spread: 18.8º35.2 m (115.5 ft)

1 fc maximum distance

Illuminance at DistanceeW Burst Powercore gen24000 K, 20° diffuser lens 0 25 45 65 90

0 13342 13342 13342 13342 133425 11282 11415 11537 11583 1151115 2498 2421 2508 2562 257225 312 316 324 332 32735 82 82 79 82 7845 38 38 36 36 3355 22 19 21 18 1765 6 8 9 6 575 4 6 6 4 285 2 3 1 3 290 0 2 0 0 1

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 0.99 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 0.991.15 1.13 1.11 1.10 1.13 1.11 1.09 0.97 1.07 1.06 1.04 1.03 1.02 1.01 1.00 0.99 0.98 0.971.12 1.08 1.05 1.03 1.09 1.06 1.04 0.94 1.03 1.01 0.99 1.00 0.99 0.97 0.98 0.96 0.95 0.941.08 1.04 1.01 0.98 1.07 1.03 0.99 0.92 1.00 0.98 0.95 0.98 0.96 0.94 0.96 0.94 0.93 0.911.05 1.00 0.97 0.94 1.04 0.99 0.96 0.90 0.97 0.94 0.92 0.95 0.93 0.91 0.94 0.92 0.90 0.891.03 0.97 0.93 0.90 1.01 0.96 0.93 0.87 0.95 0.92 0.89 0.93 0.91 0.89 0.92 0.90 0.88 0.871.00 0.94 0.90 0.88 0.99 0.94 0.90 0.85 0.92 0.89 0.87 0.91 0.88 0.86 0.90 0.88 0.86 0.850.98 0.92 0.88 0.85 0.97 0.91 0.88 0.84 0.90 0.87 0.85 0.89 0.86 0.84 0.88 0.86 0.84 0.830.95 0.89 0.86 0.83 0.95 0.89 0.85 0.82 0.88 0.85 0.83 0.87 0.84 0.82 0.86 0.84 0.82 0.810.93 0.87 0.84 0.81 0.93 0.87 0.83 0.80 0.86 0.83 0.81 0.85 0.83 0.81 0.85 0.82 0.80 0.790.91 0.85 0.82 0.79 0.91 0.85 0.82 0.79 0.84 0.81 0.79 0.84 0.81 0.79 0.83 0.81 0.79 0.78

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 1753.9 93.8%0-40 1806.6 96.6%0-60 1848.9 98.9%60-90 11.8 0.6%70-100 5.4 0.3%90-120 2.9 0.2%0-90 1860.7 99.5%90-180 9.4 0.5%0-180 1870.1 100.0%

Zonal Lumen

Cd: 0

2,333

4,667

7,000

9,333

11,667

14,000

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Lumens Efficacy CRI1,847 65.4 82

Lumens Efficacy CRI1,812 64.4 82

Page 15: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide 15

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

217 fc

54 fc

24 fc

14 fc

9 fc

6 fc

2.9

5.8

8.7

11.6

14.5

17.4

2.8 ft

5.5 ft

8.3 ft

11.0 ft

13.8 ft

16.5 ft

�� Horiz. Spread: 38º�� Vert. Spread: 39.8º18 m (59 ft)

1 fc maximum distance

Illuminance at DistanceeW Burst Powercore gen24000 K, 40° diffuser lens 0 25 45 65 90

0 3464 3464 3464 3464 34645 3318 3297 3278 3273 327815 2323 2231 2173 2145 216825 1188 1130 1075 1039 104435 434 411 387 366 35345 124 120 110 104 9755 42 42 41 39 3665 22 21 18 19 1575 10 12 10 7 685 2 1 2 2 290 3 1 0 0 1

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 0.99 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 0.991.14 1.11 1.09 1.07 1.11 1.09 1.07 0.94 1.05 1.03 1.01 1.01 1.00 0.98 0.97 0.96 0.95 0.941.08 1.04 1.00 0.97 1.06 1.02 0.99 0.89 0.99 0.96 0.94 0.96 0.94 0.92 0.93 0.91 0.90 0.881.04 0.98 0.93 0.89 1.02 0.96 0.92 0.84 0.93 0.90 0.87 0.91 0.88 0.86 0.89 0.86 0.84 0.830.99 0.92 0.87 0.83 0.97 0.91 0.86 0.79 0.89 0.84 0.81 0.87 0.83 0.80 0.85 0.82 0.79 0.780.94 0.87 0.81 0.77 0.93 0.86 0.81 0.75 0.84 0.80 0.76 0.82 0.79 0.76 0.81 0.78 0.75 0.740.90 0.82 0.77 0.73 0.89 0.81 0.76 0.71 0.80 0.75 0.72 0.78 0.74 0.71 0.77 0.74 0.71 0.700.87 0.78 0.73 0.69 0.85 0.77 0.72 0.67 0.76 0.71 0.68 0.75 0.71 0.68 0.74 0.70 0.67 0.660.83 0.74 0.69 0.65 0.82 0.74 0.69 0.64 0.73 0.68 0.65 0.72 0.67 0.64 0.71 0.67 0.64 0.630.80 0.71 0.65 0.62 0.79 0.70 0.65 0.61 0.69 0.65 0.61 0.68 0.64 0.61 0.68 0.64 0.61 0.600.76 0.68 0.62 0.59 0.75 0.67 0.62 0.58 0.66 0.62 0.59 0.66 0.61 0.58 0.65 0.61 0.58 0.57

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 1428.4 79.4%0-40 1656.1 92.0%0-60 1765.0 98.1%60-90 24.7 1.4%70-100 9.9 0.6%90-120 3.4 0.2%0-90 1789.7 99.4%90-180 10.0 0.6%0-180 1799.7 100.0%

Zonal Lumen

Cd: 0

583

1,167

1,750

2,333

2,917

3,500

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

114 fc

28 fc

13 fc

7 fc

5 fc

3 fc

14.5 ft

9.1 ft

13.6 ft

18.1 ft

22.7 ft

27.2 ft

4.5 ft

9.1 ft

13.6 ft

18.2 ft

22.7 ft

27.3 ft

�� Horiz. Spread: 59.2º�� Vert. Spread: 59.1º13 m (42.6 ft)

1 fc maximum distance

Illuminance at DistanceeW Burst Powercore gen24000 K, 60° diffuser lens 0 25 45 65 90

0 1816 1816 1816 1816 18165 1767 1768 1777 1783 179715 1492 1490 1507 1534 157325 1079 1081 1097 1122 116435 604 594 599 615 64345 217 213 213 219 22755 67 65 64 64 6265 28 27 26 24 2275 12 13 11 9 785 3 3 2 2 190 2 1 1 1 0

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.001.13 1.10 1.07 1.05 1.10 1.08 1.05 0.93 1.04 1.02 1.00 1.00 0.98 0.97 0.96 0.95 0.94 0.921.07 1.02 0.97 0.94 1.05 1.00 0.96 0.86 0.97 0.93 0.90 0.93 0.91 0.88 0.91 0.88 0.87 0.851.01 0.94 0.89 0.84 0.99 0.93 0.88 0.79 0.90 0.86 0.82 0.87 0.84 0.81 0.85 0.82 0.80 0.780.95 0.87 0.81 0.77 0.93 0.86 0.81 0.73 0.84 0.79 0.75 0.82 0.78 0.74 0.80 0.76 0.74 0.720.90 0.81 0.75 0.70 0.88 0.80 0.74 0.68 0.78 0.73 0.69 0.77 0.72 0.69 0.75 0.71 0.68 0.660.85 0.76 0.69 0.65 0.84 0.75 0.69 0.63 0.73 0.68 0.64 0.72 0.67 0.64 0.70 0.66 0.63 0.620.81 0.71 0.64 0.60 0.79 0.70 0.64 0.59 0.69 0.63 0.59 0.68 0.63 0.59 0.66 0.62 0.59 0.570.76 0.66 0.60 0.56 0.75 0.66 0.60 0.55 0.65 0.59 0.55 0.64 0.59 0.55 0.63 0.58 0.55 0.530.73 0.62 0.56 0.52 0.71 0.62 0.56 0.51 0.61 0.55 0.52 0.60 0.55 0.51 0.59 0.55 0.51 0.500.69 0.59 0.53 0.49 0.68 0.58 0.52 0.48 0.57 0.52 0.48 0.57 0.52 0.48 0.56 0.51 0.48 0.47

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 1128.5 63.3%0-40 1519.0 85.2%0-60 1747.0 98.0%60-90 31.3 1.8%70-100 9.9 0.6%90-120 0.8 0.0%0-90 1778.3 99.7%90-180 4.6 0.3%0-180 1782.9 100.0%

Zonal Lumen

Cd: 0

317

633

950

1,267

1,583

1,900

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Lumens Efficacy CRI1,782 63.4 82

Lumens Efficacy CRI1,782 63.4 82

Page 16: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide16

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

77 fc

19 fc

9 fc

5 fc

3 fc

2 fc

5.9 ft

11.8 ft

17.7 ft

23.6 ft

29.5 ft

35.4 ft

6.1 ft

12.1 ft

18.2 ft

24.2 ft

30.3 ft

36.3 ft

�� Horiz. Spread: 74.2º�� Vert. Spread: 72.8º10.7 m (35 ft)

1 fc maximum distance

eW Burst Powercore gen2 4000 K, 80° diffuser lens 0 25 45 65 90

0 1228 1228 1228 1228 12285 1214 1221 1230 1239 124215 1142 1162 1183 1207 122725 995 1023 1050 1079 110635 681 696 713 731 75045 314 312 315 318 32155 101 98 97 94 8965 36 35 34 31 2875 16 14 13 11 985 3 3 3 2 190 2 3 2 1 0

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.001.12 1.09 1.06 1.04 1.10 1.07 1.04 0.92 1.03 1.01 0.99 0.99 0.97 0.96 0.96 0.94 0.93 0.911.06 1.00 0.95 0.91 1.03 0.98 0.94 0.84 0.95 0.91 0.88 0.92 0.89 0.86 0.89 0.87 0.84 0.830.99 0.92 0.86 0.81 0.97 0.90 0.85 0.76 0.87 0.83 0.79 0.85 0.81 0.78 0.83 0.79 0.77 0.750.93 0.84 0.78 0.73 0.91 0.83 0.77 0.69 0.81 0.76 0.71 0.79 0.74 0.71 0.77 0.73 0.70 0.680.87 0.78 0.71 0.66 0.86 0.77 0.70 0.63 0.75 0.69 0.65 0.73 0.68 0.64 0.71 0.67 0.64 0.620.82 0.72 0.65 0.60 0.80 0.71 0.64 0.58 0.69 0.63 0.59 0.68 0.63 0.59 0.66 0.62 0.58 0.570.77 0.66 0.59 0.55 0.76 0.66 0.59 0.53 0.64 0.58 0.54 0.63 0.58 0.54 0.62 0.57 0.53 0.520.73 0.62 0.55 0.50 0.71 0.61 0.55 0.49 0.60 0.54 0.50 0.59 0.53 0.50 0.58 0.53 0.49 0.480.69 0.58 0.51 0.46 0.67 0.57 0.51 0.45 0.56 0.50 0.46 0.55 0.50 0.46 0.54 0.49 0.46 0.440.65 0.54 0.47 0.43 0.64 0.53 0.47 0.42 0.52 0.47 0.43 0.52 0.46 0.42 0.51 0.46 0.42 0.41

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 921.9 52.8%0-40 1364.0 78.1%0-60 1701.6 97.4%60-90 40.9 2.3%70-100 12.0 0.7%90-120 1.0 0.1%0-90 1742.4 99.7%90-180 4.4 0.3%0-180 1746.9 100.0%

Zonal Lumen

Cd: 0

217

433

650

867

1,083

1,300

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Illuminance at Distance

Center Beam fc Beam Width

4 ft

8 ft

12 ft

16 ft

20 ft

24 ft

883 fc

221 fc

98 fc

55 fc

35 fc

25 fc

0.5 ft

1.0 ft

1.6 ft

2.1 ft

2.6 ft

3.1 ft

3.0 ft

6.0 ft

9.0 ft

12.0 ft

15.1 ft

18.1 ft

�� Horiz. Spread: 41.2º�� Vert. Spread: 7.4º 36.3 m (119 ft)

1 fc maximum distance

Illuminance at DistanceeW Burst Powercore gen24000 K, 10° x 40° asymmetric lens 0 25 45 70 90

0 14123 14123 14123 14123 141235 4565 5144 6964 11336 1377115 395 462 760 3230 1005925 102 131 219 732 477835 43 50 75 204 131045 22 29 35 72 21955 9 11 20 29 6165 5 6 10 13 2875 4 3 3 4 785 2 1 1 2 190 3 0 1 1 2

Polar Candela Distribution

RCC %: 80 70 50 30 10 0RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0

E�ective Floor Cavity Re�ectance: 20%

RCR: 0 1 2 3 4 5 6 7 8 910

1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.001.15 1.12 1.10 1.08 1.12 1.10 1.08 0.96 1.06 1.05 1.03 1.02 1.01 1.00 0.99 0.98 0.97 0.951.10 1.06 1.03 1.00 1.08 1.05 1.02 0.92 1.01 0.99 0.97 0.98 0.97 0.95 0.96 0.94 0.93 0.911.06 1.01 0.97 0.94 1.04 1.00 0.96 0.88 0.97 0.94 0.92 0.95 0.92 0.90 0.93 0.91 0.89 0.881.03 0.97 0.92 0.89 1.01 0.96 0.92 0.85 0.94 0.90 0.88 0.92 0.89 0.87 0.90 0.87 0.86 0.840.99 0.93 0.88 0.85 0.98 0.92 0.88 0.82 0.90 0.87 0.84 0.89 0.85 0.83 0.87 0.84 0.82 0.810.96 0.89 0.85 0.81 0.95 0.88 0.84 0.79 0.87 0.83 0.80 0.86 0.82 0.80 0.84 0.82 0.79 0.780.93 0.86 0.81 0.78 0.92 0.85 0.81 0.77 0.84 0.80 0.78 0.83 0.80 0.77 0.82 0.79 0.77 0.760.90 0.83 0.78 0.75 0.89 0.82 0.78 0.74 0.81 0.78 0.75 0.81 0.77 0.75 0.80 0.77 0.74 0.730.87 0.80 0.76 0.73 0.87 0.80 0.76 0.72 0.79 0.75 0.73 0.78 0.75 0.72 0.77 0.74 0.72 0.710.85 0.78 0.73 0.71 0.84 0.77 0.73 0.70 0.77 0.73 0.70 0.76 0.73 0.70 0.75 0.72 0.70 0.69

Coefficients Of Utilization - Zonal Cavity MethodZone Lumens % Luminaire0-30 1590.1 87.8%0-40 1719.7 95.0%0-60 1786.1 98.7%60-90 15.3 0.8%70-100 6.4 0.4%90-120 2.8 0.2%0-90 1801.4 99.5%90-180 8.7 0.5%0-180 1810.1 100.0%

Zonal Lumen

Cd: 0

2,500

5,000

7,500

10,000

12,500

15,000

VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Lumens Efficacy CRI1,752 62.3 82

Lumens Efficacy CRI1,798 64 82

Page 17: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide 17

eW Burst Powercore gen2 SpecificationsDue to continuous improvements and innovations, specifications may change without notice.

* Correlated color temperature (CCT) complies with ANSI C78.377-2008 for the chromaticity of solid state lighting products.

† Lumen output measurements comply with IES LM-79-08 testing procedures.‡ Refer to www.philipscolorkinetics.com/support/appnotes/ for more information.§ Lxx = xx% lumen maintenance (when light output drops below xx% of initial output). All values are given at

B10, or the median value where 90% of the LED population is better than the reported or calculated lumen maintenance measurement.

¶ Lumen maintenance figures are based on lifetime prediction graphs supplied by LED source manufacturers. Whenever possible, figures use measurements that comply with IES LM-80-08 testing procedures. In accordance with TM-21-11, Reported values represent the interpolated value based on six times the LM-80-08 total test duration (in hours). Calculated values represent time durations that exceed six times the total test duration.

Item Specification Details

Output

Beam Angle 6° primary optic Optional diffusers: 10°/20°/40°/60°/80°/10° x 40° (asymmetric)

Color Temperature* 2700 K 3000 K 3500 K 4000 K

Lumens † 1,851 1,890 1,919 2,096

Efficacy 64.7 66 67.3 74.6

CRI 81 83 82 81

Effective Projected Area (EPA) 0.026053 m2 (Luminaire plus Full Glare Shield)

Electrical

Input Voltage 100 to 277 VAC, auto-switching, 50/60 Hz via Data Enabler Pro

Power Consumption 30 W maximum at full output, steady state

Power Factor > 0.9 @ 100 to 240 VAC, > 0.85 @ 277 VAC

Control ‡ Control System ON/OFF; precision dimming by 4 conductor cable & Data Enabler Pro

Physical

Dimensions (Height x Width x Depth)

287 x 210 x 186 mm (11.3 x 8.3 x 7.3 in) Architectural

272 x 163 x 185 mm (10.7 x 6.42 x 7.28 in) Landscape

Weight 5.5 kg (12.1 lb) Architectural 3.5 kg (7.7 lb) Landscape

Housing Die-cast aluminium, powder-coated finish

Lens Clear tempered glass

Luminaire Connections 1.8 m (6 ft) combined power data whip Architectural 152 mm (6 in) flying leads Landscape

Temperature Ranges-40 to 50 °C (-40 to 122 °F) Operating -20 to 50 °C (-4 to 122 °F) Startup -40 to 80 °C (-40 to 176 °F) Storage

Humidity 0 to 95%, non-condensing

Luminaire Run Lengths

To calculate luminaire run lengths and total power consumption for your specific installation, download the Configuration Calculator from www.philipscolorkinetics.com/support/install_tool/

Certification and Safety

Certification UL/cUL, FCC Class A, CE, PSE, CQC, RCM

Environment Dry/Damp/Wet Location, IP66

Corrosion Resistance Complies with ASTM B117 standard for > 1,500 hours

Vibration Resistance Complies with ANSI C136.31, 3G Architectural

Mechanical Impact IK08

6 º

20 º 40 º

60 º 80 º

10 º40 º

10 º

Lumen MaintenanceThreshold§ Ambient Temperature Reported¶ Calculated

L90@ 25°C 28,000 hrs 28,000 hrs

@ 50°C 27,000 hrs 27,000 hrs

L70@ 25°C 51,000 hrs 84,000 hrs

@ 50°C 51,000 hrs 83,000 hrs

L50@ 25°C 51,000 hrs >100,000 hrs

@ 50°C 51,000 hrs >100,000 hrs

45 mm(1.8 in) 15

mm

(0.6

in)

186 mm (7.3 in)210 mm (8.3 in)

Ø163 mm(6.4 in)

287

mm

(11.

3 in

)

Ø5.4 mm(0.21 in)

120.5 mm(4.74 in)

62.9

mm

(2.4

7 in

)

62.9 mm(2.47 in)

eW Burst Powercore gen2 Architectural

eW Burst Powercore gen2 Landscape

90 mm(3.56 in)

20 m

m(0

.77

in)

185 mm (7.28 in)

12.7 mm (0.5 in) NPS Thread

272

mm

(10.

7 in

)

Ø163 mm(6.42 in)

Page 18: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide18

Item Type CCT Housing Color Item Number* Philips 12NC

eW Burst Powercore gen2 Landscape

2700 K

Gray 523-000098-00 912400133357

Black 523-000098-03 912400133360

White 523-000098-06 912400133363

Bronze 523-000098-09 912400133366

3000 K

Gray 523-000098-24 912400135372

Black 523-000098-27 912400135375

White 523-000098-30 912400135378

Bronze 523-000098-33 912400135381

3500 K

Gray 523-000098-36 912400135384

Black 523-000098-39 912400135387

White 523-000098-42 912400135390

Bronze 523-000098-45 912400135393

4000 K

Gray 523-000098-12 912400133369

Black 523-000098-15 912400133372

White 523-000098-18 912400133375

Bronze 523-000098-21 912400133378

eW Burst Powercore gen2 Architectural

2700 K

Gray 523-000098-01 912400133358

Black 523-000098-04 912400133361

White 523-000098-07 912400133364

Bronze 523-000098-10 912400133367

3000 K

Gray 523-000098-25 912400135373

Black 523-000098-28 912400135376

White 523-000098-31 912400135379

Bronze 523-000098-34 912400135382

3500 K

Gray 523-000098-37 912400135385

Black 523-000098-40 912400135388

White 523-000098-43 912400135391

Bronze 523-000098-46 912400135394

4000 K

Gray 523-000098-13 912400133370

Black 523-000098-16 912400133373

White 523-000098-19 912400133376

Bronze 523-000098-22 912400133379

Luminaires and Data Enabler Pro

*Use Item Number when ordering in North America.

Item Style Item Number* Philips 12NC

Data Enabler Pro3/4 in / 1/2 in NPT (U.S. trade size conduit) 106-000004-00 910503701210

PG21/PG13 (metric size conduit) 106-000004-01 910503701211

Page 19: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide 19

Item Housing Color Item Number* Philips 12NC

Trim Ring

Gray 120-000189-20 912400135449

Black 120-000189-21 912400135450

White 120-000189-22 912400135451

Bronze 120-000189-23 912400135452

Half Glare Shield

Gray 120-000189-24 912400135453

Black 120-000189-25 912400135454

White 120-000189-26 912400135455

Bronze 120-000189-27 912400135456

Full Glare Shield

Gray 120-000189-28 912400135457

Black 120-000189-29 912400135458

White 120-000189-30 912400135459

Bronze 120-000189-31 912400135460

Louver Black 120-000189-17 912400133447

10° Diffuser Lens 120-000189-18 912400135371

20° Diffuser Lens 120-000189-12 912400133442

40° Diffuser Lens 120-000189-13 912400133443

60° Diffuser Lens 120-000189-14 912400133444

80° Diffuser Lens 120-000189-15 912400133445

10º x 40° Asymmetric Lens 120-000189-16 912400133446

Mounting Arm, Short* Black 120-000201-00 912400135840

Mounting Arm, Medium* Black 120-000201-01 912400135841

Mounting Arm, Long* Black 120-000201-02 912400135842

Mounting Arm, Short* Gray 120-000201-03 912400135843

Mounting Arm, Medium* Gray 120-000201-04 912400135844

Mounting Arm, Long* Gray 120-000201-05 912400135845

Mounting Arm, Short* White 120-000201-06 912400135846

Mounting Arm, Medium* White 120-000201-07 912400135847

Mounting Arm, Long* White 120-000201-08 912400135848

Accessories

Use Item Number when ordering in North America.

E You can attach either one Louver or one Diffuser Lens at a time.

E Diffuser and Louver must be ordered with a trim ring or a glare shield.

*Mounting Arm does not meet ANSI C136.31-2010 standard with a 3G vibration rating.

Page 20: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide20

InstallationeW Burst Powercore gen2 offers solid white light LED spotlighting, site, and accent lighting with Powercore technology. Powercore, which integrates LED power and data management within the luminaire, eases installation by eliminating the need for external power supplies.

Owner/User Responsibilities It is the responsibility of the contractor, installer, purchaser, owner, and user to install, maintain, and operate eW Burst Powercore gen2 luminaires in such a manner as to comply with all applicable codes, state and local laws, ordinances, and regulations. Consult with the appropriate electrical inspector to ensure compliance.

Installing in Damp or Wet LocationsWhen installing in damp or wet locations, it is good practice to seal all luminaires and junction boxes with electronics-grade RTV silicone sealant to ensure that moisture cannot enter or accumulate in any wiring compartments, cables, or other electrical parts. You must use suitable outdoor-rated junction boxes when installing in wet or damp locations. Additionally, you must use gaskets, clamps, and other parts required for installation to comply with all applicable local and national codes

Planning a Precision Dimming InstallationeW Burst Powercore gen2 can be dimmed using a Data Enabler Pro setup. If you plan on precision dimming eW Burst Powercore gen2, you will need to plan out your installation.

1. Determine the appropriate location of each Data Enabler Pro in relation to the light luminaires, and of the light luminaires in relation to each other.

eW Burst Powercore gen2 luminaires can be installed in series or in parallel (wired to a common junction box). The maximum number of luminaires each Data Enabler Pro can support depends on specific configuration details such as luminaire spacing, circuit size, line voltage, and method of connection (in series or in parallel). For more information, and for help calculating the number of luminaires your specific installation can support, download the Configuration Calculator from www.colorkinetics.com/support/install_tool/, or consult Application Engineering Services at [email protected].

In addition to maximum luminaire run lengths determined by the electrical configuration, each Data Enabler Pro imposes maximum run lengths based on data integrity. To ensure data integrity, maximum individual run length should not exceed 53.3 m (175 ft), and the total cable length per Data Enabler Pro should not exceed 122 m (400 ft).

2. On an architectural diagram or other diagram that shows the physical layout of the installation, identify the locations of all switches, controllers, Data Enabler Pro devices, luminaires, and cables.

eW Burst Powercore gen21 channel31 @ 100 VAC 38 @ 120 VAC57 @ 220 VAC58 @ 230 VAC62 @ 227 VAC

Maximum luminaire run lengths

Assuming a 20 A circuit, 6.1 m (20 ft) leader cable from Data Enabler Pro to the first junction box, and 610 mm (2 ft) jumper cables between luminaires

E For more information, and for help calculating the number of luminaires your specific installation can support, download the Configuration Calculator from www.colorkinetics.com/support/install_tool/, or consult Application Engineering Services at [email protected].

E Refer to the eW Burst Powercore gen2 Installation Instructions for specific warning and caution statements.

E To streamline the configuration of complex installations, record the serial number (DMX) or IP address (Ethernet) and location of each Data Enabler Pro.

Data Enabler Pro

Luminaires

Data integrity — 53.3 m (175 ft) maximum individual length

Luminaires

Data integrity — 122 m (400 ft) maximum total length

Data Enabler Pro

Page 21: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide 21

3. Each eW Burst Powercore gen2 luminaire comes pre-programmed with a unique serial number. As you unpack the luminaires, record the serial numbers in a layout grid (typically a spreadsheet or list) for easy reference and light addressing.

4. Assign each luminaire to a position in the lighting design plan.

5. To streamline installation and aid in light show programming, you can affix a weatherproof label identifying the order or placement in the installation to an inconspicuous location on each light luminaire’s housing.

Start the Installation 1. Install all Data Enabler Pro devices, including any interfaces with controllers.

Data Enabler Pro devices and external controllers send power and control signals to the luminaires over a single luminaire cable. Additional cabling is required to connect luminaires together in parallel or in series.

2. Verify that all additional supporting equipment (switches, controllers) is in place.

3. Ensure that all additional parts and tools are available, including:

eW Burst Powercore gen2 Architectural Installations

• The provided stainless steel screws for outdoor installations

• The provided junction box gasket for outdoor installations

• Unless surface-mounting, one 102 mm (4 in) round US electrical junction box per luminaire, rated for your application, with 89 mm (3.5 in) center-to-center screw holes for attaching the luminaire’s base. (Refer to the manufacturer’s literature for additional items required for mounting or sealing.)

• A 6 mm hex wrench for luminaire tilting and locking

• A 1/8 in hex wrench for luminaire swiveling and locking

eW Burst Powercore gen2 Landscape Installations

• The provided locking nut

• One electrical junction box or mounting accessory per luminaire, rated for your application. (Refer to the junction box or accessory manufacturer’s literature for specific information on mounting or sealing.)

• A 6 mm hex wrench for luminaire tilting and locking

• A 33 mm wrench for locking luminaires in place

All Installations

• A sufficient length 4-conductor wire. We recommend 12 AWG 4 mm² (0.1 in) stranded copper wire.

• Conduit as required

• Electronics-grade room temperature vulcanizing (RTV) silicone sealant as required

• A 5/32 in hex wrench for installing accessories.

E For complete instructions on how to wire the Data Enabler Pro, refer to the Data Enabler Pro Product Guide.

Page 22: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide22

Unpack and Position Luminaires 1. Carefully inspect the box containing eW Burst Powercore gen2 and the contents

for any damage that may have occurred in transit.

2. Each eW Burst Powercore gen2 luminaire comes pre-programmed with a unique serial number. As you unpack the luminaires, record the serial numbers in a layout grid (typically a spreadsheet or list) for easy reference and light addressing.

3. Assign each luminaire to a position in the lighting design plan.

4. To streamline installation and aid in light show programming, you can affix a weatherproof label identifying the order or placement in the installation to an inconspicuous location on each light luminaire’s housing.

Connecting and Mounting eW Burst Powercore gen2 Architectural Luminaires eW Burst Powercore gen2 Architectural luminaires can be mounted to standard US junction boxes, or they can be mounted to a flat surface or substrate.

Make sure the power is OFF before mounting and connecting eW Burst Powercore gen2 luminaires.

Connecting eW Burst Powercore gen2 Architectural Luminaires to Junction Boxes1. Mount junction boxes in accordance with the lighting design plan. Each luminaire

is designed for mounting in a 102 mm (4 in) round US electrical junction box, rated for your application, with 89 mm (3.5 in) center-to-center screw holes for attaching the luminaire’s base.

Architectural luminaires are supplied with a grounding wire attached to the luminaire’s base (canopy). The canopy ground wire can be attached to a grounding point in the junction box, or connected with the ground in the luminaire cable.

Wiring between junction boxes must comply with local codes.

2. If installing luminaires in a series, pull copper wire between the junction boxes.

If installing luminaires in parallel, pull copper wire from a Data Enabler Pro to a common junction box, and from the common junction box to each luminaire’s junction box.

We recommend the use of 12 AWG 4 mm² (0.1 in), stranded 4-conductor copper wire. With the recommended wiring, the maximum cable run from a Data Enabler Pro device to any individual eW Burst Powercore gen2 luminaire is 53 m (174 ft). When installing in parallel, the total cable length cannot exceed 122 m (400 ft).

Architectural Landscape

Included in the boxeW Burst Powercore gen2 ArchitecturaleW Burst Powercore gen2 Architectural luminaire(4) 10-24 stainless steel screws for outdoor installationJunction box gasketInstallation Instructions

eW Burst Powercore gen2 LandscapeeW Burst Powercore gen2 Landscape luminaireLocking nutInstallation Instructions

Page 23: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide 23

3. Trim the cable from the luminaire to fit in the junction box, leaving enough cable to make wiring connections.

4. Use wire nuts to connect line, neutral, ground, and data. If installing in a damp or wet location, use the included junction box gasket.

Attach the canopy ground wire to a grounding point in the junction box, or combine it with the luminaire cable ground with a wire nut.

5. Tuck wire connections into the junction box.

6. Screw the luminaire’s canopy base into the junction box using the four included 10-24 stainless steel screws. If installing in a damp or wet location, seal all junction boxes with electronics-grade RTV silicone sealant. Use gaskets, clamps, and other parts and fittings required to comply with local outdoor wiring codes.

RTV Silicone

RTV Silicone

RTV Silicone

RTV Silicone

9.5 mm(0.375 in)

18 AWG1 mm (0.04 in)

Leader Cable connector dimensions

E When there is a solo green or yellow wire attached to the canopy, it is a canopy ground wire that must not be removed. Connect this wire to a suitable grounding point in the junction box or elsewhere nearby.

L N

Precision Dimming

Standard ON/OFF Control

Page 24: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide24

Surface-Mounting eW Burst Powercore gen2 Architectural Luminaires 1. Prepare eW Burst Powercore gen2 Architectural luminaires for surface-mounting:

• Loosen the cable compression ring on the luminaire yoke.

• Remove the nylon cable clamp from the luminaire’s leader cable where it exits the underside of the canopy base.

• Disengage the leader cable from the luminaire’s canopy base.

2. Mount junction boxes in accordance with the lighting design plan.

3. Position each eW Burst Powercore gen2 Architectural luminaire in its designated mounting location. Make sure the mounting surface is flat, suitable for the mounting hardware, and clear of debris and other obstructions.

4. Use four suitable mounting screws to secure each eW Burst Powercore gen2 Architectural luminaire to the mounting location.

Page 25: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide 25

Install luminaires in series or in parallel

5. If installing luminaires in a series, pull copper wire between the junction boxes.

If installing luminaires in parallel, pull copper wire from a Data Enabler Pro to a common junction box.

We recommend the use of 12 AWG 4 mm² (0.1 in), stranded 4-conductor copper wire. With the recommended wiring, the maximum cable run from a Data Enabler Pro device to any individual eW Burst Powercore gen2 luminaire is 53 m (175 ft). When installing in parallel, the total cable length cannot exceed 122 m (400 ft).

6. Use wire nuts to connect line, neutral, ground, and data. If installing in a damp or wet location, use the included junction box gasket.

7. Tuck wire connections into the junction box.

8. Secure all junction box covers. If installing in a damp or wet location, seal all junction boxes with electronics-grade RTV silicone sealant. Use gaskets, clamps, and other parts and fittings required to comply with local outdoor wiring codes.

Connecting and Mounting eW Burst Powercore Landscape Luminaires eW Burst Powercore gen2 Landscape luminaires feature a 1/2 in NPT threaded post for installing to standard junction boxes, stanchion mounts, posts, stakes, and other landscape mounting accessories.

Make sure the power is OFF before mounting and connecting eW Burst Powercore gen2 luminaires.

1. Mount junction boxes and any landscape mounting accessories in accordance with the lighting design plan.

2. If installing luminaires in a series, pull copper wire between the junction boxes, and from the junction boxes to the luminaires as needed.

If installing luminaires in parallel, pull copper wire from a Data Enabler Pro to a common junction box, and from the common junction box to the luminaires.

We recommend the use of 12 AWG 4 mm² (0.1 in), stranded 4-conductor copper wire. With the recommended wiring, the maximum cable run from a Data Enabler Pro device to any individual eW Burst Powercore gen2 luminaire is 53 m (175 ft). When installing in parallel, the total cable length cannot exceed 122 m (400 ft).

3. Thread the locking nut onto the eW Burst Powercore gen2 Landscape threaded post.

4. Use wire nuts to connect line, neutral, ground, and data.

RTV Silicone

RTV Silicone

9.5 mm(0.375 in)

18 AWG1 mm (0.04 in)

Leader Cable connector dimensions

L N

Page 26: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide26

5. Tuck wire connections into the junction box or mounting accessory.

6. Using a 33 mm wrench, torque the locking nut to 33.9 Nm (25 ft-lb). Do not overtighten.

7. If installing in a damp or wet location, seal all junction boxes and mounting accessories with electronics-grade RTV silicone sealant. Use gaskets, clamps, and other parts and fittings required to comply with local outdoor wiring codes.

Connect Luminaire Cable to PowerOnce you’ve made all luminaire and junction box connections, connect the lead cable to the 4-wire PC terminal connector block inside the Data Enabler Pro Housing.

33.9 Nm (max)25 ft-lb (max)

33 mm(1.19 in)

RTV Silicone

RTV Silicone

RTV Silicone

RTV Silicone

L N

L N

DMX

DMX

Mains voltage input

Power/data output to luminaires

E Refer to the Data Enabler Pro Product Guide for comprehensive installation and configuration instructions. You can view or download the guide from www.colorkinetics.com/ls/pds/dataenablerpro

L N

Precision DimmingStandard ON/OFF Control

Page 27: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide 27

Attach Safety Cable (Optional)When installing eW Burst Powercore gen2 luminaires to a wall or overhead, use a safety cable to tether it to a secure anchor point. When dictated by local or state code or advised by a structural engineer, attach a safety cable to the eW Burst Powercore gen2 luminaire housing and tether it to a secure anchor point.

1. Thread a safety cable through the luminaire housing as shown.

2. Attach the safety cable to the mounting surface using a method that follows the code or engineer’s requirements.

Attach Accessories (Optional)Accessories can be installed to change the beam angle or add extra protection to the luminaire in outdoor environments.

Architectural Landscape

Safety cable minimum requirements

Material 304 or 316 Stainless Steel

Size4 mm (5/32 in) nominal diameter Minimum break load must be greater than 1,089 kg (2,400 lb)

Trim Ring 45° Glare Shield Full Glare Shield

Louver Diffuser Lenses

E For complete instructions on how to install the accessories, refer to the Accessory Installation Instructions.

10° 20° 40° 60° 80° 10° x 40°

Mounting Arm

Page 28: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide28

Address and Configure the Luminaires Make sure the power is ON before addressing and configuring luminaires.

eW Burst Powercore gen2 luminaires operate in 8-bit mode by default. You can configure eW Burst Powercore gen2 to operate in 16-bit mode, which increases luminaire resolution for smoother dimming.

eW Burst Powercore gen2 luminaires come factory-addressed with a starting DMX address of 1. For lighting designs where luminaires work in unison, all luminaires can be assigned the same starting DMX address. Changes to the default starting DMX address are not necessary, but if lights were previously readdressed for use in other installations, you must reset them. For light show designs that show different colors on different luminaires, you must assign unique DMX addresses to your luminaires and sort them in a useful order.

• In Ethernet installations, you can address and configure your luminaires using QuickPlay Pro with a computer connected to your lighting installation’s network. QuickPlay Pro can automatically discover all of your luminaires, controllers, and Data Enabler Pro devices for quick configuration.

• In DMX installations, you can address and configure your luminaires using QuickPlay Pro with iPlayer 3 or SmartJack Pro. You can manually enter luminaire serial numbers, or you can import a spreadsheet listing each luminaire’s serial number and starting DMX address.

For complete details on addressing and configuring eW Burst Powercore gen2 luminaires with QuickPlay Pro, refer to the Addressing and Configuration Guide, which you can view or download at www.colorkinetics.com/support/addressing.

Setting Luminaire Dimming CurvesDimming curves describe how slowly or quickly a luminaire dims at different levels of input. For finer control, eW Burst Powercore gen2 offers three different dimming curves for use in different situations and applications:

• Normal The non-linear (gamma) dimming curve used in most Philips Color Kinetics LED lighting luminaires. eW Burst Powercore gen2 luminaires use the normal dimming curve by default.

• Linear A dimming curve with a linear relationship between power input and DMX output.

• Tungsten A non-linear dimming curve that emulates the dimming curve of incandescent lamps on a DMX dimmer. This curve offers the most control at low intensities.

Setting LED Transition SpeedNormally, LEDs react to DMX or other control data instantaneously. In some cases, you may want to slow down the reaction speed to achieve smoother transitions when the intensity of different LED channels changes. eW Burst Powercore gen2 offers five levels of decreasing LED transition speed, from Fast (instant snap changes) to Delay-4 (slowest transition speed).

E You will need the layout grid that you created when you recorded the serial numbers of the light luminaires in your installation.

E You can address luminaires and switch between 8-bit mode and 16-bit mode using QuickPlay Pro. You can download QuickPlay Pro from www.colorkinetics.com/support/addressing/

Page 29: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

eW Burst Powercore gen2 Product Guide 29

Aim and Lock Luminaires Make sure power is ON before aiming luminaires. eW Burst Powercore gen2 luminaires can tilt through a full 180°. eW Burst Powercore gen2 Architectural luminaires can also rotate through a full 360° for precise aiming. Locking nuts use standard hex wrenches to secure luminaires firmly in position.

Aiming and Locking eW Burst Powercore gen2 Landscape Luminaires1. Using a 6 mm hex wrench, loosen the locking nut on the side of the luminaire base.

2. Aim the luminaire by tilting the beam as desired.

3. When the luminaire is aimed as desired, re-tighten the locking nut to secure the luminaire in place. Torque to 33.9 Nm (25 ft-lbs). Do not over-tighten.

6 mm

33.9 Nm (max)25 ft-lb (max)

180º

E Do not look directly into the luminaire when aiming and locking.

360°

180°

Page 30: eW Burst Powercore gen2 - Color Kinetics · eW Burst Powercore gen2 Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing

Aiming and Locking eW Burst Powercore gen2 Architectural Luminaires1. To tilt the beam:

• Loosen the locking nuts on either side of the luminaire yoke using a 6 mm hex wrench.

• Tilt the beam as desired.

• Re-tighten the locking nuts to secure the luminaire in place. Torque to 28 Nm (21 ft-lbs). Do not over-tighten.

2. To rotate the luminaire:

• Loosen the locking nuts on either side of the luminaire yoke’s base using a 3 mm hex wrench.

• Rotate the luminaire as desired. Note that the luminaire can be rotated in 10˚ increments.

• Re-tighten the locking nuts to secure the luminaire in place.

10º

360º

10º

360º

10º

360º

10º

360º

6 mm hex

28 Nm (max)21 ft-lb (max)

6 mm hex

28 Nm (max)21 ft-lb (max)

DAS-000176-00 R01 29 Dec 2017

Copyright © 2017 Philips Lighting Holding B.V. All rights reserved. Chromacore, Chromasic, CK, the CK logo, Color Kinetics, the Color Kinetics logo, ColorBlast, ColorBlaze, ColorBurst, eW Fuse, ColorGraze, ColorPlay, ColorReach, iW Reach, eW Reach, DIMand, EssentialWhite, eW, EvenBalance, iColor, iColor Cove, IntelliWhite, iW, iPlayer, Optibin, Powercore and PureGlow are either registered trademarks or trademarks of Philips Lighting Holding B.V. in the United States and/or other countries. All other brand or product names are trademarks or registered trademarks of their respective owners. Due to continuous improvements and innovations, specifications may change without notice.

Philips Color Kinetics3 Burlington Woods DriveBurlington, Massachusetts 01803 USATel 888.385.5742Tel 617.423.9999Fax 617.423.9998www.colorkinetics.com