GAS LEAK DETECTOR
MODEL: EW-401
Expl anati ons
EWOO ENG NEERI NG CO. , LTD.
-
8/7/2019 EW-401_3
2/10
Tabl e of Contents
1. Speci fi cati ons1-1. Speci fi cati ons of the I ndi cator (EW401)
1-2. Speci fi cati ons of the Detector
2. Functi on of Each Devi ce and T tl e Expl anati ons2-1. I ndi cator
2-2. Detector
3. Wri ng D agram
4. Operati on System D agram
5. I nstal l ati on P ace and I nstal l ati on Drawng
6. Operati on Method and I nstructi ons
-
8/7/2019 EW-401_3
3/10
1. Product Speci fi cati ons1-1. Speci fi cati ons of the I ndi cator
Name Gas Leak Detector (MODEL:EW401)
Detector GasesLPG LNG Ci ty Gas (Methane, Butane, Propane)
Combusti bl e Gas
Power AC 220V. 60 (AC 230V 50 AC110V/ 50 opti on)
Power Consumpti on Normal : 2. 5W. Al arm: 3W
Operati ng Temperature Range
and Humi di ty-10~ 50, 0~95% RH
Readout Range 0 ~ 100% LEL
Al arm Poi nt Wi thi n 25% (user adj ustabl e*Vari abl e setti ng)
Response Ti me Wi thi n 20 seconds
Vi sual Al arm and Audi o Al arm Fl i ckeri ng of LED LAMP (yel l ow) and above 70Db of buzzer sound
Operati ng I ndi cator Li ghti ng of LED LAMP (green)
Troubl e I ndi cator Li ghti ng of LED LAMP (Red)
Warm up Ti me 60 seconds
Connecti on Cabl e VCT or CVVS above O. 75mm SQ Use over
Di mensi on 114*250*80
Outer OutputDC 12V(20~30mA Output). Contact poi nt of non-vol tage
contact poi nt NO. NC. COM(Rel ay contact poi nt)
Capaci ty of Contact Poi nt AC 110/1A. DC 12~24 2A
Wei ght Some 1,840g
1-2. Speci fi cati ons of the Detector
Type Expansi on Type
Detector Gases LPG LNG Ci ty Gas (Methane, Butane, Propane) Combusti bl e Gas
Sensor Type Catal yti c, Combusti on (Hot-wi re type) Di ffusi on Type
Operati ng Temperature Rang
and Humi di ty-20~ 50, 0~95% RH
Expl osi on-proof Type ExdBT
Cabl e Connector I nsi de Di a 16mm/ Outer Di a 23mm
Di mensi on 137*142*75
Wei ght 1,036g
Readout Range 0~100%(LEL)
Response Ti me Wi thi n 20 seconds
-
8/7/2019 EW-401_3
4/10
2. Functi on of Each Part and T tl e Expl anati ons2-1. I ndi cator (EW401)
Power Lamp Troubl e Si gnal
- Lamp to confi rm el ectri ci ty status - Li ghted i n case of abnormal detecti on devi ce or i ts l i ne
(Green LED) (Red LED)
Ci rcui t Test Swi tch Reset Swi tch
- To confi rm operati on status of recei ver - As al arm i s kept i n case of gas l eakage or l i ne test,
uni t i nternal ci rcui t i t wi l l be reversed when reversi on swi tch i s pushed after
(Al arm, l evel meter, buzzer, rel ay) i t drops on the densi tometer.
Buzzer stop Lamp Gas Densi ty I ndi cator
- I n case of pushi ng the swi tch agai nst - Expanded gas densi ty i s marked by l amp l evel meter.
Al arm, buzzer turns off, and l amp around LEL I ndi cati on
swi tch and etc. turn off. - Tabl e i ndi cati ng l amp l evel meter and LEL conversi on
Buzzer Stop Swi tch
-I n case of pushi ng the buzzer stop swi tch agai nst al arm, al arm
sound stops and i n case numeri cal val ue of re-pushi ng, al arm i s sounded.
-
8/7/2019 EW-401_3
5/10
2-2. Detector
Sensor fi xi ng hol e Sti cker
- The hol e for fi xi ng the detector by bol ts or nai l s -4m*6m
Si ntered Fi l ter Ground earth
- Sensor protecti on fi l ter (bronze 300mesh) -M4*6mm
Cover Fi xi ng bol t Mol ded Cover
- The bol t for fi xi ng cover and body of Detector
Cabl e grand Mol ded Body
Cabl e I nsert Devi ce Wi re
-Cabl e pi pe or fi exi bl e screw(Femal e screw) -VCTF 0. 75x3C (Bl ue, Brown, Green)
-
8/7/2019 EW-401_3
6/10
3. Wri ng D agram
110/220 I nput: To fi x the power suppl y sel ecti on swi tch to AC110V or 220V
and then to connect the l i ne. (AC230V 50 AC110V/ 50 opti on)
Non-vol tage contact poi nt (NO. NC. COM): Contact (Swi tch) COM termi nal and
NC termi nal are connected at ordi nary ti mes. I n case of al armi ng, COM termi nal and
NO termi nal are connected.
Sensor Connecti on Termi nal (Bl ue, Brown, Green): I t i s connected to be
matched wi th wi re col ors arranged i n detecti on devi ce. Bl ue (El ectri c Li ne +),
Brown (El ectri c Li ne +), Green (Si gnal Li ne)
Si gnal Output (+. -): I n case of al armi ng, i t can be used for shut-off devi ce or
other vari ous devi ces wi th DC12V 30mA output.
-
8/7/2019 EW-401_3
7/10
4. Operati on System D agram
-
8/7/2019 EW-401_3
8/10
5. I nstal l ati on P ace and I nstal l ati on drawng5-1. I nstal l ati on Pl ace1. Detecti on devi ce shal l be i nstal l ed i n the pl ace where the l eaked
gas easi l y stays, as the pl ace where gas i s easi l y l eaked among
storage faci l i ti es and gas faci l i ti es.
2. The l ocati on where detecti on devi ce i s i nstal l ed, shal l be deci ded
as per the condi ti ons such as characteri sti cs of gas, i nstructi ons,
structure of each devi ce and etc.
3. As for i nstal l ati on hei ght of detecti on devi ce, i f the gas heavi er than
ai r, i t shal l be i nstal l ed wi thi n 30cm above the fl oor whi l e i f the one
l i ghter than ai r, i t shal l be i nstal l ed wi thi n 30cm bel ow the cei l i ng.
4. I nstal l ati on pl ace for recei ver devi ce of gas l eak al arm devi ce shal l
be i nstal l ed i n the proper pl ace to take every measure after al arm i s
sounded, as the pl ace where the rel evant person resi des or the al arm
can be i denti fi ed.
-
8/7/2019 EW-401_3
9/10
5-2. I nstal l ati on Drawi ng
I nstal l ati on Pl ace: Ki tchen of the restaurant, boi l er room, governor room
and gas storage room.
6. Operati on Method and I nstructi onsOperati on Method
1. To open the front case and to fi x the swi tch to the operati on vol tage
after fi ni shi ng the connecti on of recei ver devi ce and detecti on devi ce.
2. I n case power suppl y swi tch turns on, power suppl y l amp wi l l
be fl i ckered for some one mi nute, and i n case earl y stabi l i zati on
ti me i s passed, power suppl y l amp wi l l stops fl i ckeri ng and be l i ghted
and ci rcui t wi l l be operated i n normal way.
3. I n case detecti on devi ce i s di sconnected, buzzer i s sounded and
troubl e si gnal i s l i ghted.
-
8/7/2019 EW-401_3
10/10
4. As for test operati on of gas l eak al arm devi ce, i n case of pushi ng the
ci rcui t test button, densi ty si gnal l amp i s sl owl y up as gas i s
detected, and then when al arm setti ng devi ce i s abnormal , al arm si gnal
l amp i s l i ghted and al arm i s sounded.
5. I n case of pushi ng the buzzer button i n order to stop the al arm sound,
normal operati on wi l l be made as i t becomes i n normal .
6. I n case di sconnecti on si gnal and troubl e l amp are l i ghted, to confi rm
the detecti on devi ce and connecti on status.
I nstructi ons
1. Opti onal di sassembl y, repai r or al terati on i s not al l owed by an
person except the rel evant personnel of our company.
2. As for the product equi pped wi th earthi ng termi nal , earthi ng
l i ne shal l be surel y i nstal l ed
3. I n case of connecti ng recei ver devi ce and detecti on devi ce, the same
manufacturi ng number shal l be connected.
4. To confi rm the vol tage before i nstal l ati on, to match 110V/220V
conversi on swi tch to operati on vol tage.
5. Do not use any other gas except appl i cati on objecti ve gas.
6. Do not use i t i n the pl ace where there i s hi gh vapor or strong wi nd.
7. Pl ease check the detecti on el ement more than one ti me per year.