Evacuation Slide Evacuation Slide Test Evacuation SlideThe slide material test result correlation...

12
1 Evacuation Slide Comparison Test Results Tim Marker (for Dung Do) Fire Safety Branch FAA Wm. J. Hughes Technical Center Atlantic City International Airport, NJ 08405 International Aircraft Materials Fire Test Working Group Meeting March 6, 2018 Evacuation Slide Evacuation Slide Test Results of RR6 and Updated AC Power Controller

Transcript of Evacuation Slide Evacuation Slide Test Evacuation SlideThe slide material test result correlation...

Page 1: Evacuation Slide Evacuation Slide Test Evacuation SlideThe slide material test result correlation determined that both of the heaters are acceptable for use in the Revised Test Method,

1

Evacuation Slide

Test Method: Comparison Test Results

Tim Marker (for Dung Do) Fire Safety Branch FAA Wm. J. Hughes Technical Center

Atlantic City International Airport, NJ 08405

International Aircraft Materials Fire Test Working Group

Meeting March 6, 2018

Evacuation Slide

Evacuation Slide Test

Results of RR6 and Updated

AC Power Controller

Page 2: Evacuation Slide Evacuation Slide Test Evacuation SlideThe slide material test result correlation determined that both of the heaters are acceptable for use in the Revised Test Method,

Activity

Evacuation Slide Round Robin 6:

Tests were conducted on typical slide materials to ensure the Revised Test Method is functioning properly

• 2 different heaters were used for the Tests

H1 = Part # 38000 and H2 = Part # 40400

• 3 materials were tested; 3 tests of each material

Page 3: Evacuation Slide Evacuation Slide Test Evacuation SlideThe slide material test result correlation determined that both of the heaters are acceptable for use in the Revised Test Method,

Heater part # 68086038000,

1.5-inch coil-to-face distance.

Heater part # 68086040400,

1.75-inch coil-to-face distance.

Heaters Used in Testing

Page 4: Evacuation Slide Evacuation Slide Test Evacuation SlideThe slide material test result correlation determined that both of the heaters are acceptable for use in the Revised Test Method,

The Heater coil depth is adjustable

Open the screw on the heater, and adjust the head cover until the distance of the coil from the face of the heater is 1.5” if using the heater with (Part # 68086038000) and 1.75” if using heater with (Part # 68086040400)

Head Cover

Heater

Solid Coil

Screw

Adjusting

Page 5: Evacuation Slide Evacuation Slide Test Evacuation SlideThe slide material test result correlation determined that both of the heaters are acceptable for use in the Revised Test Method,

0

10

20

30

40

50

60

FAA Heater 1 FAA Heater 1 FAA Heater 1 FAA Heater2 FAA Heater2 FAA Heater2

1 2 3 4 5 6

Heat Flux = 1.5 Btu/ ft2sec = 428 watts

Tim

e (

Seco

nd

s)

Test Results of the Mustard / Mustard slide material to compare two different heaters

Page 6: Evacuation Slide Evacuation Slide Test Evacuation SlideThe slide material test result correlation determined that both of the heaters are acceptable for use in the Revised Test Method,

Test Results of the Blue / Gray slide material to compare two different heaters

3.3

3.4

3.5

3.6

3.7

3.8

3.9

4

Heater 1 Heater 1 Heater 1 Heater 2 Heater 2 Heater 2

1 2 3 4 5 6

Pressure @ t = 0 t = 90 (S) t = 180 (S) t = 240 (S) t= 300 (S)

Pre

ssu

re (

Psi

)

Page 7: Evacuation Slide Evacuation Slide Test Evacuation SlideThe slide material test result correlation determined that both of the heaters are acceptable for use in the Revised Test Method,

2.5

2.6

2.7

2.8

2.9

3

3.1

3.2

3.3

3.4

3.5

Heater 1 Heater 1 Heater 1 Heater 2 Heater 2 Heater 2

1 2 3 4 5 6

Pressure @ t = 0 t = 90 (S) t = 180 (S) t = 240 (S) t= 300 (S)

Pre

ssu

re (

Psi

)

Test Results of the Ivory / Gray slide material to compare two different heaters

Page 8: Evacuation Slide Evacuation Slide Test Evacuation SlideThe slide material test result correlation determined that both of the heaters are acceptable for use in the Revised Test Method,

Conclusions

Blue / Gray Material and Ivory / Gray Material passed the tests with both heaters (Gray side faced the radiant heat).

Mustard / Mustard Material Failed the tests with both heaters.

The slide material test result correlation determined that both of the heaters are acceptable for use in the Revised Test Method, provided the coil distances are accurately adjusted.

Page 9: Evacuation Slide Evacuation Slide Test Evacuation SlideThe slide material test result correlation determined that both of the heaters are acceptable for use in the Revised Test Method,

Recent Activities

Preparation for additional testing using the new AC Power Controller (Keysight AC 6802A) to replace the Powerstat Voltage Regulator, which was used to control the input power of the heaters:

• The new AC Power Controller will provide feedback control of the power input to the heater. When the power input is set to the required wattage, it will be continuously controlled throughout the duration of the test.

• Time will be saved because the power input to the heater will be stabilized and won’t be need to be monitored or adjusted. Simply set it and conduct the test. (no need for Operator to check the power input during the test).

• Tests on additional slide materials will be conducted to evaluate the new AC Power Controller function.

Page 10: Evacuation Slide Evacuation Slide Test Evacuation SlideThe slide material test result correlation determined that both of the heaters are acceptable for use in the Revised Test Method,

AC Voltage Controllers for The Power Input of Heaters

Powerstat Voltage Regulator

NEW AC Power Controller (Keysight 6802A) $4871

Page 11: Evacuation Slide Evacuation Slide Test Evacuation SlideThe slide material test result correlation determined that both of the heaters are acceptable for use in the Revised Test Method,

New AC Power Controller was installed for additional Evacuation Slide Tests

AC 8602A Power Controller

Radiant Heater

Monitor

Page 12: Evacuation Slide Evacuation Slide Test Evacuation SlideThe slide material test result correlation determined that both of the heaters are acceptable for use in the Revised Test Method,

Future Work

Tests will be conducted on typical slide materials using the New AC Power Controller (Keysight AC 6802A):

• Calibration tests will be conducted to evaluate the stabilization of the power input to the heater

• 2 different materials will be tested

• 3 tests on each material

The slide material test results will be presented at the next meeting