Eurosens fuel flow meters installation

56
Installation of the Fuel flow meters eurosens Direct & eurosens Delta

Transcript of Eurosens fuel flow meters installation

Page 1: Eurosens fuel flow meters installation

Installation of the Fuel flow meters

eurosens Direct & eurosens Delta

Page 2: Eurosens fuel flow meters installation

• current fuel consumption records• registration of machinery operation time• normalizing of fuel consumption limits• fuel theft detection and prevention• real-time monitoring and fuel consumption

optimization;• fuel consumption tests for engines

Application

Page 3: Eurosens fuel flow meters installation

• 3 Hall-effect detectors• No need in check valves• Built-in temperature sensors in each chamber• Wear-resistant coating of measuring chamber• No hidden defects in material structure• 3 Year warranty

Unique features

Page 4: Eurosens fuel flow meters installation

Some more Advantages

• Modifications with built-in display• Electric disturbance protection• Smart calibration possibilities• Automotive-type built-in connector• Built-in temperature compensation• LED and LCD status indication• Reversing and adding of flow

Page 5: Eurosens fuel flow meters installation

The flow sensor measures the amount of fuel flowing through the measuring chamber. Pressurized fluid coming through the inlet nozzle flow sensor in the inlet of the measuring chamber, the piston slides along the inner surface of the chamber and simultaneously slides along the jumper. The piston displaces fluid enclosed in it inside and outside of the piston chamber through its outlet to the outlet port

Operation principle

Page 6: Eurosens fuel flow meters installation

SpecificationConnecting thread M14x1, 5

Max pressure 2.5 MPaPower voltage, V 10 – 50Reverse polarity protection Yes

Measuring accuracy* ±1%

Temperature range,°C -40 – +85Maximum flow rate in l/h * 500

Output interface pulses, RS232, RS485, K-Line, CAN

Seal rating IP 66

Page 7: Eurosens fuel flow meters installation

EUROSENS flow meters can measure:

• Diesel fuel• Heating oil• Motor fuel• Biofuels

Other liquids :

fuels and mineral oil with a kinematic viscosity of 1.5 to 6 mm2 / s.

Page 8: Eurosens fuel flow meters installation

Product lines

Single chamber - Direct Differential- Delta

Page 9: Eurosens fuel flow meters installation

ModificationsDirect P - Not normalized pulse outputРH - Not normalized pulse output, external magnetic field protectionPN - Normalized pulse outputI – bult-in LCD 05 – enhanced precisionА – autonomous counter (built-in battery) RS – interfaces RS232 and RS485

Page 10: Eurosens fuel flow meters installation

ModificationsDelta РH - Not normalized pulse output, external magnetic field protectionPN - Normalized pulse outputI – bult-in LCD 05 – enhanced precisionА – autonomous counter (built-in battery) RS – interfaces RS232 and RS485CAN – J1939 or NMEA2000 interface

Page 11: Eurosens fuel flow meters installation

Порядок установки

1. Assessment of the engine condition2. Flowmeter mounting3. Connection of hoses4. Electric connection5. Testing operation6. Precision test

Page 12: Eurosens fuel flow meters installation

Connection of the hoses

Use fuel connectors from Eurosens mounting kit or compatible.

Fuel hoses must be resistant to oils and fuels

Use only high-quality mounting kits!

Page 13: Eurosens fuel flow meters installation

Flow meter installation

• Flanges and threaded connections must be clean during connection.

• When installing, use only new copper sealing from the mounting kit.

• Fuel lines must be protected from external destructive effects. • It is not allowed to reduce the internal cross section of the fuel

lines on the bends. • Fuel hoses on the vehicle must be fixed every 0.5 m.

Page 14: Eurosens fuel flow meters installation

Flow meter installation

• Fuel hoses in length should have a small length margin to compensate temperature changes.

• Do not install a flow sensor on the elements of the vehicle, subject to strong vibrations and heat.

• After flow sensor is installed it is necessary to remove air from the fuel system.

• It is recommended to install extra fine fuel (or filters) filter before the flowmeter chambers and let engine run for 30 minutes to collect all possible dirt after installation. Then filters can be removed.

Page 15: Eurosens fuel flow meters installation

Flow meter installation

Installation schemes:

1. “at pressure side”(after fuel supply pump)

2. “at suction side”(before fuel supply pump)

3. Differential scheme

Page 16: Eurosens fuel flow meters installation

Installation of the Direct flow meter(fuel system before installation)

Page 17: Eurosens fuel flow meters installation

Installation of the Direct flow meter(at pressure side)

Check valve is required only for “P” modifications

Page 18: Eurosens fuel flow meters installation

At pressure sideAdvantages1. Flow meter is installed after fine fuel filter .2. Fuel is under pressure that make system more tolerable for dirt

particles. 3. Return line still back in tank.

Disadvantages4. High-pressure pump has less cooling.5. Temperature of fuel in the return line is lower – less heating of fuel in

the tank6. Engine warranty will be ended.

Page 19: Eurosens fuel flow meters installation

Installation of the Direct flow meter(fuel system before installation)

Page 20: Eurosens fuel flow meters installation

Installation of the Direct flow meter(at pressure side)

Check valve is required only for “P” modifications

Page 21: Eurosens fuel flow meters installation

Check if the air bubbles in the return line are present

Check air bubbles at hot engine, at idle, middle and max RPMs

Page 22: Eurosens fuel flow meters installation

Check the fuel temperature at high-pressure pump entrance

Page 23: Eurosens fuel flow meters installation

Installation at suction side

Install if needed:• Radiator• Deaerator

If it is difficult – just try Eurosens Delta!

Check:• ∆t C of fuel• Air in return line

Page 24: Eurosens fuel flow meters installation

Installation at Suction side

Advantages1. Minimal changes of the fuel system

 Недостатки 2. You may need extra fuel filter to be installed.3. Increased load at fuel supply pump.4. Fuel in the tank is not heated anymore by fuel from return line.5. Troublesome diagnostics of fuel system operation.6. Air in the return line problem requires deaerator installation

Page 25: Eurosens fuel flow meters installation

Installation of the differential flow meter(supply chamber at pressure side)

Page 26: Eurosens fuel flow meters installation

Installation of the differential flow meter(supply chamber at pressure side)

Page 27: Eurosens fuel flow meters installation

Differential scheme Differential method of measurement does high demands to flow meter precision. It is because flow rates in supply and return line usually are much bigger than engine fuel consumption.

For example, for John Deere tractor , at idling in fuel supply line – 200 liters/hour, in return line – 197 liters/hour. Engine consumption – 3 liters/hour. That means, that for adequate result at idling we need to measure both fuel flows with precision no more than 0.3%. Moreover, temperature expansion of fuel (0.7% per every 10 Celsius degrees) add extra error to differential measurement, because temperature of fuel coming to engine and returning to tank is differ.

That means, you can’t use idea of 2 separate flow meters without good precision and temperature correction.

Fuel flow meters Delta are made from hard aluminium alloy, measuring chambers have antifriction coating, in both measuring chambers fuel temperature sensor is installed. Each manufactured flow meter is pre-calibrated for differential application. Thereby Delta flow meters can provide accurate results in any mode of engine operation.

Page 28: Eurosens fuel flow meters installation

Differential schemeAdvantages1. No changes in the fuel system. 2. Can be installed at engines during warranty.

Disadvantages3. More costly flow meter model. 4. Precision is a bit lower. 5. Air in the return line will require deaerator

installation

Page 29: Eurosens fuel flow meters installation

Inline plunger high-pressure pump

Page 30: Eurosens fuel flow meters installation

For such old-schooled engines you can use Direct installation at pressure side

Page 31: Eurosens fuel flow meters installation

Mercedes, MAN,…

Common Rail fuel system

Page 32: Eurosens fuel flow meters installation

Common Rail

Page 33: Eurosens fuel flow meters installation

VOLVO

Fuel injectors

Page 34: Eurosens fuel flow meters installation

DAF

PLD fuel system

Page 35: Eurosens fuel flow meters installation

Differential scheme is suggested (Unipump UP DAF)

Page 36: Eurosens fuel flow meters installation

Electric connection of P и PN modifications

Green

Black

Blue

Page 37: Eurosens fuel flow meters installation

Electric connection of RS modifications

Red

Brown

Blue

Black

Wight

Yellow

Green

Page 38: Eurosens fuel flow meters installation

Connection of «Ground»Ground wire must be connected to the same point with Ground wire of GPS tracker

Page 39: Eurosens fuel flow meters installation

Power wire must be connected to the same point with Power wire of GPS tracker. Use 1.5A fuse for flow meter circuit protection.

Connection of power«+»

Page 40: Eurosens fuel flow meters installation

You may use electric clamps

Page 41: Eurosens fuel flow meters installation

Sometimes incorrect results from flow meter may be caused by electric disturbances in the wiring

Page 42: Eurosens fuel flow meters installation

Very good if your software can show instant fuel consumption based at flow meter data. You may easy check if flow meter works correctly

Page 43: Eurosens fuel flow meters installation

How to check precision of flow meter

"Refueling" method

1. Refill fuel tank for max, till visible level of fuel.2. Leave vehicle to perform its usual operations to consume at least 1/2 of tank.3. After it make refueling till max and visible level of fuel in tank again and measure volume of refueling.4. Compare volume of refueling with consumed fuel volume by flow meter.

Page 44: Eurosens fuel flow meters installation

"Measuring tank" method

What do you need for this method:

1. Calibrated standard measuring tank of the 2nd precision class, 10 liters 2. Clean capacities, >10 liters3. 500-1000 ml capacity measuring flask of the 2nd class with a continuous

scale4. Transparent fuel hoses  - 2 pieces.

Page 45: Eurosens fuel flow meters installation

"Measuring tank" method

1. Connect fuel system like shown at this picture

Page 46: Eurosens fuel flow meters installation

"Measuring tank" method

1. Supply and return lines will come from tank capacity with some fuel volume inside.

2. Start engine and let it run until both fuel hoses will be fulfilled by fuel. No air bubbles is allowed.

3. Prepare second tank with exactly 10 liters. Attach it to the vehicle tightly.4. Connect second tank instead of first one. Fuel inside fuel hoses must be

saved.

Page 47: Eurosens fuel flow meters installation

"Measuring tank" method

Page 48: Eurosens fuel flow meters installation

"Measuring tank" method

5. Let vehicle perform its usual duties. No pure idling is allowed. Vehicle must spend some fuel in idle, normal and hard load more (preferably). So you can test flow meter in all operation conditions.  Be sure that supply hose fully immersed in fuel and air can't get into fuel system.

6. Stop engine. Remove fuel hoses from measuring tank. Fuel from the hoses must not drop in measuring tank.

7. Measure rest of fuel from measuring tank and calculate fuel consumption. Compare it with fuel meter data.

Page 49: Eurosens fuel flow meters installation

Measuring tank with simulated fuel comsumption method

Same with previous method. •

But you must have much bigger tank capacities - at least 50 liters.

• Make extra fuel hose connection between relief valve and connect it with extra fuel capacity with 50 liters.

• Install an usual crane in this hose.

• Connect PC with configuration software or Eurosens Display to see instant fuel rates during experiment.

• See picture

Page 50: Eurosens fuel flow meters installation

Measuring tank with simulated fuel comsumption method

Page 51: Eurosens fuel flow meters installation

Measuring tank with simulated fuel comsumption method

You can now simulate engine consumption by opening crane. Fuel will pass fuel secondary tank before return chamber of flow meter.

As flow rates in supply/return line is much bigger than fuel consumption - 10 liters is not enough.

Thats why we need least 50 liters for an experiment. Fuel in supply tank will finish fast.

Measure rest of fuel in supply tank and compare with fuel flow meter data.

Page 52: Eurosens fuel flow meters installation

Intervention to the sensor operationFuel theft after sensorWhat you can see:

Fuel consumption is always higher than normal

Page 53: Eurosens fuel flow meters installation

Fuel theft after Direct flow meter

What you can see:Sometimes fuel consumption is

abnormal

Intervention to the sensor operation

Page 54: Eurosens fuel flow meters installation

Fuel theft example

Page 55: Eurosens fuel flow meters installation

For fuel flow meter installation you will need USB Destination 01 adapter

Configuration

Page 56: Eurosens fuel flow meters installation

Спасибо за внимание

Спасибо за внимание

Приглашаемк партнерству

Спасибо за внимание

Спасибо за внимание

Приглашаемк партнерству

Thank you for attention

JSC «Mechatronics»

222417 Vilejka, 1St May, 80BelarusPhone: +375 (1771) 71300Fax: +375 (1771) 24190E-mail: [email protected] www.mechatronics.by