ETSI EN 302-208

13
1 RFID and Telecommunication Services 25th May 2004 DATA BASE forum Sigurd Bolt Sørensen, Bolt Consult Vice - Chairman ETSI-ERM-TG34 [email protected] ETSI, Sophia Antipolis, 25 May 2004 RFID Standards & Regulations

Transcript of ETSI EN 302-208

Page 1: ETSI EN 302-208

1

 RFID and Telecommunication Services25th May 2004

DATA BASE forum

Sigurd Bolt Sørensen, Bolt ConsultVice - Chairman ETSI-ERM-TG34

[email protected]

ETSI, Sophia Antipolis, 25 May 2004

RFID Standards & Regulations

Page 2: ETSI EN 302-208

2

 RFID and Telecommunication Services25th May 2004

DATA BASE forum

Frequencies for RFID

- LF: 120 kHz to 135 kHz for inductive systems

- HF: 13.56 MHz for smart cards and labels- UHF: 433 MHz for low power, active tags- UHF: 863 to 870 MHz, 902 to 928 MHz and

950 to 956 MHz depending on country- µWave: 2.45 GHz for Industrial applications

Page 3: ETSI EN 302-208

3

 RFID and Telecommunication Services25th May 2004

DATA BASE forum

Regulatory Standards

Current three Generic ETSI Standards:

- EN 300 330: 9 kHz - 30 MHz

- EN 300 220: 25 MHz to 1 GHz

- EN 300 440: 1 GHz – 40 GHz

Page 4: ETSI EN 302-208

4

 RFID and Telecommunication Services25th May 2004

DATA BASE forum

Current Limitations at UHF in Europe

- RFID at UHF currently restricted to band 869.40 - 869.65 MHz

- Must comply with EN 300 220- Transmitted power < 500 mW e.r.p.- Duty cycle < 10%

Impossible restrictions for RFID at UHF

Page 5: ETSI EN 302-208

5

 RFID and Telecommunication Services25th May 2004

DATA BASE forum

ETSI RFID Standard at UHF

EN 300 220 does not meet needs of RFID at UHF

Formation of TG 34 within ETSI to address the specific requirements of RFID industry

Design of new ETSI standard EN 302 208 to satisfy market for RFID at UHF

Page 6: ETSI EN 302-208

6

 RFID and Telecommunication Services25th May 2004

DATA BASE forum

Principle requirements

Draft ETSI standard EN 302 208 proposes the following:

Shared operation in band 865.0 – 868.0 MHz at transmit powers up to 2 W e.r.p.

Mandatory “listen before talk” function Operation in sub-bands of 200 kHz Power levels of 100 mW, 500 mW and 2 W e.r.p.

Page 7: ETSI EN 302-208

7

 RFID and Telecommunication Services25th May 2004

DATA BASE forum

RF Power Limits at UHF

865.0MHz

868.0MHz

865.6MHz

867.6MHz

100 mW

2 W

500 mW

Page 8: ETSI EN 302-208

8

 RFID and Telecommunication Services25th May 2004

DATA BASE forum

RFID Transmission Times

Mandatory listen time of >5 msec before each transmission

Maximum period of continuous transmission of 4 sec

Pause of 100 msec between repeated transmissions on same sub-band, ormove immediately to another vacant sub-band

Page 9: ETSI EN 302-208

9

 RFID and Telecommunication Services25th May 2004

DATA BASE forum

Scope of EN 302 208

The technical requirements of ETSI Standard EN 302 208 are based on inputs provided by RFID manufacturers throughout the entire standardisation process.

The standard will permit operation in Europe of product built in compliance with ISO 18000-6

The standard may not permit operation of some new systems that are currently under development

Page 10: ETSI EN 302-208

10

 RFID and Telecommunication Services25th May 2004

DATA BASE forum

Regulatory Issues

RFID classified as SRD meaning: Type approval only Operate within a shared band No protection Regulated by new Annex 11 of

ECC/ CEPT ERC/Rec 70-03

Page 11: ETSI EN 302-208

11

 RFID and Telecommunication Services25th May 2004

DATA BASE forum

Status of ETSI Standard EN 302 208

Predicted Milestones:

Approval of Regulation by ECC in April 04 Public Enquiry (PE) period ended

PE Resolution meeting completed in May 04

Expect approval for National Vote by June 04

Expect publication in OJ in Autumn 2004

Page 12: ETSI EN 302-208

12

 RFID and Telecommunication Services25th May 2004

DATA BASE forum

Status of ECC/CEPT Regulation

Predicted Milestones:

Draft Regulation as Annex 11 to ERC/Rec 70-03, first March 2004

Approved for Consultation April 2004 Expect final approval and publication

September/October 2004

Page 13: ETSI EN 302-208

13

 RFID and Telecommunication Services25th May 2004

DATA BASE forum

Contact Details

Sigurd Bolt SørensenBolt Consult

Lindetoften 23

2630 Taastrup

Denmark

Tel: +45 52 68 08

Mob: +45 20 42 30 92

[email protected]