Et herNet/IP Error C ode Decoder - Omron Automation...

17
Et therN Net/IP P Err ror C Code Dec oder Version 12/19/ r n 2.20 /2014

Transcript of Et herNet/IP Error C ode Decoder - Omron Automation...

Page 1: Et herNet/IP Error C ode Decoder - Omron Automation Americasproducts.omron.us/Asset/EtherNetIP_Error_Code... · 2 3 4 5. Using the and modif read the d Get Attrib informatio. Respons

Et

therNNet/IP

P Errror C

Code Decoder

Version12/19/

 

 

r

n 2.20 /2014

Page 2: Et herNet/IP Error C ode Decoder - Omron Automation Americasproducts.omron.us/Asset/EtherNetIP_Error_Code... · 2 3 4 5. Using the and modif read the d Get Attrib informatio. Respons

 

This docconnectinand NJ p Section

1. G

2. U

mri

3. R

ument is inteng EtherNet

products. De

n 1: Readin

Go online wit

Upload the pamodule is diff

ght clicking

Right Click on

ended to hel/IP devices tetailed troub

ng the Erro

h the Omron

arameters frferent from ton the PLC

n the PLC / M

f

Pa

lp the user idto Omron PL

bleshooting p

or Code

n Network C

rom the PLCthe configura/ MAC, and

MAC and se

age 2 of 16 

dentify the cLC and MACprocedures f

Configurato

C / MAC if theation in the Nselecting Pa

elect Monito

causes of errC controllersfor common

or for EtherN

e configuratNetwork Conarameter / U

or.

ror codes ges such as CSerrors are a

Net/IP.

ion in the Etnfigurator foUpload.

enerated whS1, CJ2, CJ1also provided

therNet/IP r EtherNet/IP

  

en 1, d.

P by

Page 3: Et herNet/IP Error C ode Decoder - Omron Automation Americasproducts.omron.us/Asset/EtherNetIP_Error_Code... · 2 3 4 5. Using the and modif read the d Get Attrib informatio. Respons

 

4. GNRin

Go to the CoNodes with coRefer to the enformation.

nnection taommunicatioerror code lis

Pa

b. The detaons errors wst in Section

age 3 of 16 

ailed error cowill be shown

2 of this do

ode for eachn with a red cocument for t

h device is shcircle next tothe specific e

hown in Stato the node. error

  

tus.

Page 4: Et herNet/IP Error C ode Decoder - Omron Automation Americasproducts.omron.us/Asset/EtherNetIP_Error_Code... · 2 3 4 5. Using the and modif read the d Get Attrib informatio. Respons

 

Section

N

01:001:001:001:001:001:001:001:001:001:001:001:001:001:001:001:001:001:001:001:001:001:001:001:001:001:001:001:001:001:001:001:001:001:001:001:001:001:0

n 2: Error C

Note: error

0100 Conne0103 Transp0106 Owne0107 Target0108 Invalid0109 Invalid0110 Target0111 RPI no0113 Out of0114 Vendo0115 Produ0116 Revis0117 Invalid0118 Invalid0119 Non-L011A Target011B RPI is011C Transp011D Produ011E Direct011F Invalid0120 Invalid0121 Invalid0122 Invalid0123 Invalid0124 Invalid0125 Invalid0126 Invalid0127 Invalid0128 Invalid0129 Invalid012A Invalid012B Invalid012C Config012D Consu012E Produ012F Incons0130 Incons

Code List

codes show

ection in use oport class andrship Conflictt connection n

d network cond connectiont for connectiot supported f connections or ID or Product Type Mision Mismatcd Produced d or inconsisteListen only cont object out of smaller thanport Class Noction Trigger ion Not Supp

d Originator tod Target to Ord Originator tod Target to Ord Originator tod Target to Ord Originator tod Configuratiod Originator d Target to Od Configuratiod Consuming d Producing Aguration Symbuming Symbocing Symbol sistent Applicsistent Consu

Pa

wn in bold h

or duplicate fod trigger comt not found nnection paran size on not config

duct Code mimatch

ch or Consumeent configuratnnection not of connections the productio

ot SupportedNot Supporteorted

o Target Netwriginator Netwo Target Netwriginator Netwo Target Netwriginator Netwo Target Netwon Size to Target Siz

Originator Sizon ApplicationApplication P

Application Pabol Does Not

ol Does Not ExDoes Not Exiation Path Co

ume Data For

age 4 of 16 

have troubl

orward openbination not s

meter

ured

ismatch

ed applicationtion applicatioopened s on inhibit time

ed

work Connectwork Connectwork Connectwork Connectwork Connectwork Connectwork Connect

zeze

n Path Path ath Exist xist ist ombination mat

eshooting p

supported

n path on path

e

tion FIXVARtion FIXVARtion Priority tion Priority tion Type tion Type tion Redunda

procedures

nt_Owner

s in section

  

3.

Page 5: Et herNet/IP Error C ode Decoder - Omron Automation Americasproducts.omron.us/Asset/EtherNetIP_Error_Code... · 2 3 4 5. Using the and modif read the d Get Attrib informatio. Respons

 

01:001:001:001:001:001:001:001:001:0

01:0

01:0

01:0

01:0

01:0

01:0

01:0

01:0

01:0

01:0

01:0

01:0

01:0

01:0

01:0

01:0

01:0

01:0

01:0

01:0

01:0

0131 Incons0132 Null F0133 Conne0203 Conne0204 Uncon0205 Param0206 Messa0207 Uncon0301 No bu

0302 Netwo

0303 No co

0304 Not co

0305 Sched

0306 Sched

0311 Port n

0312 Link a

0315 Invalid

0316 Error i

0317 Sched

0318 Link a

0319 Secon

031A Rack c

031B Modul

031C Misce

031D Redun

031E No mo

availa

031F No mo

availa

0800 Netwo

0810 No tar

0811 No ori

sistent Producorward Openection Timeouection timed onnected requemeter error in age too large nnected acknoffer memory a

ork bandwidth

nsumed conn

onfigured to s

dule signature

dule signature

ot available

address not va

d segment in

in Forward Cl

duling not spe

address to sel

ndary resourc

connection al

le connection

ellaneous

ndant connec

ore user confi

ble in the pro

ore user confi

ble in the pro

ork link in path

rget applicatio

ginator applic

Pa

ce Data Form Function No

ut Multiplier Nout est timed outunconnectedfor unconnecowledgementavailable

h not available

nection ID filte

send schedule

e mismatch

e validation no

alid

connection pa

lose service c

ecified

f invalid

ce unavailable

lready establi

already esta

ction mismatc

igurable link c

oducing modu

igurable link c

oducing modu

h to module is

on data availa

cation data av

age 5 of 16 

mat t Supported

Not Acceptable

request servcted send sert without reply

e for data

er available

ed priority dat

ot possible

ath

connection pa

e

shed

ablished

h

consumer res

le

consumer res

le

s offline

able

vailable

e

vice rvice y

ta

ath

sources

sources

  

Page 6: Et herNet/IP Error C ode Decoder - Omron Automation Americasproducts.omron.us/Asset/EtherNetIP_Error_Code... · 2 3 4 5. Using the and modif read the d Get Attrib informatio. Respons

 

Section

EdCreN 1

n 3: Troubl

EDS file diffeifferences in

Configurator ead the actu

Notepad) to m

. Using theThe Netw

leshooting

erences: En the Identityfor EtherNetal value of t

match the ha

e Network Cowork Configu

Pa

g common

Error codes y Object betwt/IP and the he parameteardware dev

onfigurator forator for Eth

age 6 of 16 

error code

01:0114, 01ween the .edactual hardw

ers from the vice.

or EtherNet/herNet/IP mu

es:

1:0115, and ds file installware devicedevice, and

/IP, select Tust be online

01:0116, ared in the Ne. To correct

d modify the

ools / Setupe to select th

re caused byetwork t these error.eds file (us

p Parametehis menu opt

  

y

rs, sing

ers. tion.

Page 7: Et herNet/IP Error C ode Decoder - Omron Automation Americasproducts.omron.us/Asset/EtherNetIP_Error_Code... · 2 3 4 5. Using the and modif read the d Get Attrib informatio. Respons

 

2

3

4

5

. Using theand modifread the dGet Attribinformatio

. Respons

number, w

. Responsnumber, w

. Responsnumber, w

e Setup Parafy the .eds fdata, send thbute Singleon.

VendCode

ProdType

ProdCode

MajRev/Mi

se to VendCwhich is byte

se to ProdTywhich is byte

se to ProdCowhich is byte

Pa

ameter tool, ile for the dehe message. Refer to th

Cla

e

nRev

Code: The ree swapped.

ype: The ree swapped.

ode: The ree swapped.

age 7 of 16 

read the valevice to matces to the IP Ahe table belo

ass Inst

01

01

01

01

esponse to rExample: 2

esponse to reExample: 0

esponse to AExample: 5

ue of each och the valueAddress of thow for Class

tance Att

01

01

01

01

reading Attri2F00 = Vend

eading Attrib0700 = Prod

Attribute 3 w5104 = Vend

of the 4 paraes read from he device, us, Instance, a

tribute

01

02

03

04

ibute 1 will bdCode 47.

bute 2 will bedType 7.

will be a hexadCode 1105

ameters showthe device.sing a servicand Attribute

be a hexadec

e a hexadec

adecimal .

  

wn, To

ce of e

cimal

cimal

Page 8: Et herNet/IP Error C ode Decoder - Omron Automation Americasproducts.omron.us/Asset/EtherNetIP_Error_Code... · 2 3 4 5. Using the and modif read the d Get Attrib informatio. Respons

 

6

7

[D 8

. ResponsMajRev inMajRev 0

. The Devithe param

Device] VendCo VendNa ProdTyp ProdTyp ProdCod MajRev MinRev ProdNam

. After makNetwork Cnetwork d

se to MajRevn hexadecim02, MinRev 0

ce section ometers, as sh

ode = 47; ame = "OMRpe = 7; peStr = "Gende = 1105; = 2; = 1; me = "ERT1

king the chanConfiguratordiagram. Re

Pa

v/MinRev: Tmal and 2 dig01.

of the .eds filhown below.

RON Corpora

neral Purpos

-MD32SLH-

nges, save tr for EtherNeeload the .ed

age 8 of 16 

The responsgits of MinRe

e should be.

ation";

se Discrete I

-1";

he file, deletet/IP, and reds file and co

se to Attributev in hexade

e modified to

/O";

te the devicemove any inomplete the

te 4 will be 2ecimal. Exam

o match the v

e from the pnstances of tconnections

2 digits of mple: 0201

values read

roduct tree ithe device ins.

  

=

from

in the n the

Page 9: Et herNet/IP Error C ode Decoder - Omron Automation Americasproducts.omron.us/Asset/EtherNetIP_Error_Code... · 2 3 4 5. Using the and modif read the d Get Attrib informatio. Respons

 

IO0thcod 1

2

O Size Mism1:031C are

he connectioorrect theseevice, deter

. Using theconsumed101.

. Using theThe Netw

matches: Ecaused by d

on to a devicerrors, read

mine the siz

e Connectiond assembly

e Network Cowork Configu

Pa

Error codes differences ince, comparedd the actual pze from the r

n informationnumbers for

onfigurator forator for Eth

age 9 of 16 

01:0109, 01n the producd to the actuproduced anesponse dat

n for the devr the device.

or EtherNet/

herNet/IP mu

1:0127, 01:0ced or consuual assemblynd consumeta, and mod

vice, determi. Shown bel

/IP, select Tust be online

0128 and somumed data sy sizes of thed assembly

dify the conn

ne the produlow are asse

ools / Setupe to select th

metimes size specifiede device. Todata from thection size.

uced and emblies 104

p Parametehis menu opt

  

d in o he

and

ers. tion.

Page 10: Et herNet/IP Error C ode Decoder - Omron Automation Americasproducts.omron.us/Asset/EtherNetIP_Error_Code... · 2 3 4 5. Using the and modif read the d Get Attrib informatio. Respons

 

3

4

. Using thedata, senAttributeAttributein hexaderead.

. Count the

2 to deterhighlight tnumber oAssemblyAssembly

e Setup Parad the messa Single. Us 3. From the

ecimal) and A

e number of rmine the nuthe entire Re

of digits. In ty 104 is 2 byy 101 is 4 by

Pa

ameter tool, ages to the Ise Class 4, Ie example inAssembly 10

digits receivumber of byteesult, and cohe example

ytes long (4 ytes long (8

ge 10 of 16 

read the rawP Address oInstance <An step 1, Ass01 (Instance

ved in the Rees. If the reopy / paste above, the digits) and tdigits).

w data for eaof the deviceAssembly Nsembly 104e 65, which

esult, and divsponse in thinto Notepadresponse tothe response

ach assemble, using a seNumber in h

(Instance 6is 101 in hex

vide the numhe Result wind to facilitate

o reading thee to reading

ly. To read tervice of Getexadecima

68, which is xadecimal) a

mber of digitndow is large counting the data from

the data fro

  

the t l>, 104 are

ts by ge, he

om

Page 11: Et herNet/IP Error C ode Decoder - Omron Automation Americasproducts.omron.us/Asset/EtherNetIP_Error_Code... · 2 3 4 5. Using the and modif read the d Get Attrib informatio. Respons

 

5 . Modify the

a. RiEd

b. Mosizdo

e Assembly

ght click on dit.

odify the asszes for the Pownload to th

Pa

Size for the

the device i

sembly sizesPLC / MAC, he PLC / MA

ge 11 of 16 

device by:

n the netwo

s as shown. modify the CAC.

rk diagram,

After modifConnection t

and selectin

fying the sizto reflect the

ng Paramete

zes, edit the e new sizes,

  

er /

Tag and

Page 12: Et herNet/IP Error C ode Decoder - Omron Automation Americasproducts.omron.us/Asset/EtherNetIP_Error_Code... · 2 3 4 5. Using the and modif read the d Get Attrib informatio. Respons

 

6

. If the abosometimefile for theIdle HeadHeader mboth connfollowing

a. AdOm

b. AdOm

c. Adfo

If this will beThe fithe PL

ve steps do es 01:031C, e EtherNet/IPder, but the hmismatch counections, so page for an

dd 4 extra bymron PLC / dd 4 extra bymron PLC / dd 4 extra byr the device

does resolve offset by 4 rst 4 bytes wLC / MAC pr

Pa

not resolve try the follow

P device indhardware dould be in thethere are 3 example of

ytes to the PMAC Tag). ytes to the CMAC Tag).ytes to both and the Om

ve the commbytes from t

will be the 32rogram.

ge 12 of 16 

error code wing to addricates that t

oes use a 32e produced cdifferent comeach of the

Produced Da

Consumed D

the Producemron PLC / M

munication erthe beginnin2 Bit Run / Id

01:0109, 0ress a specifthe product d2 Bit Run / Idconnection, tmbinations t3 combinati

ata (both the

Data (both th

ed and ConsMAC tags).

rror, the datang of the PLCdle header, a

1:0127, 01:0fic situation does not use

dle Header. the consumeto try. See thions.

e size for the

he size for th

sumed Data

a in the OmrC tag or meand should n

0128 and in which thee a 32 Bit RuThis Run / I

ed connectiohe image on

e device and

he device an

(both the si

ron PLC / MAmory addresnot be used

  

e .eds un / dle

on, or n the

the

d the

ze

AC ss. in

Page 13: Et herNet/IP Error C ode Decoder - Omron Automation Americasproducts.omron.us/Asset/EtherNetIP_Error_Code... · 2 3 4 5. Using the and modif read the d Get Attrib informatio. Respons

 Page 13 of 16 

  

Page 14: Et herNet/IP Error C ode Decoder - Omron Automation Americasproducts.omron.us/Asset/EtherNetIP_Error_Code... · 2 3 4 5. Using the and modif read the d Get Attrib informatio. Respons

 

Invalid PTag NamMAC, doare not m

1

Produced ormes used in t

not have thmarked as ne

. Verify thaa. Exb. Arc. Ar

fo

r Consumedthe Networke same sizeetwork varia

at any Tag Nxist in the PLre marked asre the correcr EtherNet/IP

Pa

d Applicatiok Configuratoe in the PLC bles in the P

ames used LC / MAC, as network vact size in theP (in Bytes).

Examp

Example fro

ge 14 of 16 

on Path: Eor for EtherNas in the Ne

PLC / MAC.

in the Netwond are spellariables or Pe PLC to mat.

ple from CX

om Sysmac

Error code 0Net/IP that doetwork Conf

ork Configured correctly

Publish Onlytch the size

X Programm

c Studio

01:0117 mayo not exist infigurator for E

rator for Ethe. . in the Netwo

mer

y be caused n the PLC / EtherNet/IP,

erNet/IP

ork Configur

  

by

, or

rator

Page 15: Et herNet/IP Error C ode Decoder - Omron Automation Americasproducts.omron.us/Asset/EtherNetIP_Error_Code... · 2 3 4 5. Using the and modif read the d Get Attrib informatio. Respons

 

Other erindicate tdoes not

Please c

rror codes: that additioncomply with

ontact Omro

Error codenal modificath the EtherN

on and / or th

Pa

es other thanions to the .e

Net/IP specifi

he EtherNet/

ge 15 of 16 

n those desceds file are nication.

/IP device m

cribed in secnecessary, o

manufacturer

ction 3 of thisor that the p

r for addition

s document roduct itself

nal support.

  

may

Page 16: Et herNet/IP Error C ode Decoder - Omron Automation Americasproducts.omron.us/Asset/EtherNetIP_Error_Code... · 2 3 4 5. Using the and modif read the d Get Attrib informatio. Respons

 

Section

1

2

3

4

n 4: Other

. Use Poinnot suppodevices b

. Remove Ebetween t

. Try differe(laptop bacausing in

. If the Statfrom the Eimproper Contact Ofrom the .document

general Et

nt to Point cort Multicast block Multica

Ethernet swthe PLC / MA

ent Ethernetags, etc.). Antermittent c

tus of the coEtherNet/IP implementa

Omron Techeds file, andt.

Pa

therNet/IP t

onnections, connections

ast packets.

itches from tAC and the

t cables. EthAlso, sometimconnections.

onnection asdevice is alwtion of the 3nical Suppod add extra b

ge 16 of 16 

troublesho

instead of Ms, or do not i

the network,EtherNet/IP

hernet cablemes cables a

read in secways 0 for a

32 Bit Run / Irt for assistabytes as des

ooting reco

Multicast conimplement th

, and use a cP device.

es degrade ware over crim

ction 1 is 00:0ll bytes receIdle Header ance removinscribed in ste

ommendat

nnections. Shem properl

crossover E

with rough usmped during

0000, but theived, this min the Etherng the Run /ep 6 of secti

tions:

Some devicey, and some

thernet cabl

se in the fielg manufactur

e data receiay indicate

rNet/IP devic/ Idle Headeion 3 of this

  

es do e IT

e

ld ring,

ived

ce. er

Page 17: Et herNet/IP Error C ode Decoder - Omron Automation Americasproducts.omron.us/Asset/EtherNetIP_Error_Code... · 2 3 4 5. Using the and modif read the d Get Attrib informatio. Respons

OMRON CANADA, INC. • HEAD OFFICEToronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com

OMRON ELECTRONICS DE MEXICO • HEAD OFFICEMéxico DF • 52.55.59.01.43.00 • 01-800-226-6766 • [email protected]

OMRON ELECTRONICS DE MEXICO • SALES OFFICEApodaca, N.L. • 52.81.11.56.99.20 • 01-800-226-6766 • [email protected]

OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICESão Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br

OMRON ARGENTINA • SALES OFFICECono Sur • 54.11.4783.5300

OMRON CHILE • SALES OFFICESantiago • 56.9.9917.3920

OTHER OMRON LATIN AMERICA SALES54.11.4783.5300

Authorized Distributor:

QSG EIP Error 12/14 Note: Specifications are subject to change. © 2014 Omron Electronics LLC Printed in U.S.A.

Printed on recycled paper.

Automation Control Systems• Machine Automation Controllers (MAC) • Programmable Controllers (PLC) • Operator interfaces (HMI) • Distributed I/O • Software

Drives & Motion Controls • Servo & AC Drives • Motion Controllers & Encoders

Temperature & Process Controllers • Single and Multi-loop Controllers

Sensors & Vision• Proximity Sensors • Photoelectric Sensors • Fiber-Optic Sensors• Amplified Photomicrosensors • Measurement Sensors• Ultrasonic Sensors • Vision Sensors

Industrial Components • RFID/Code Readers • Relays • Pushbuttons & Indicators• Limit and Basic Switches • Timers • Counters • Metering Devices • Power Supplies

Safety • Laser Scanners • Safety Mats • Edges and Bumpers • Programmable Safety Controllers • Light Curtains • Safety Relays • Safety Interlock Switches

OMRON AUTOMATION AND SAFETY • THE AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com

OMRON EUROPE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • +31 (0) 23 568 13 00 • www.industrial.omron.eu