Estap 2012-2013 catalogue all pages

228

description

rack cabinet, rack cabin, rack cabinets, rack enclosure, rack enclosures, rock cabin,data cabinet, server cabinet, network cabinet, network cabin, 19''rack cabinet, cabinet, server cabin , rack cabinet price, rack cabin price, 42U cabinet, 19'', 16U, 20U, 22U,26U, 32U,39U,44U,47U,estap elektrik, estap eskişehir,estap eskişehir factory, enclosure, rack enclosure

Transcript of Estap 2012-2013 catalogue all pages

  • 1.ESTAP HEAD OFFICE - SANCAKTEPE / STANBULESTAP FACTORY - ESKEHR40.000 m2 open area, 20.000 m2 closed area. Making production with 400 employess.

2. CONTENTS FREE STANDING CABINETS ServerMAX 600x1000 - 800x10003-22DCMax Datacenter solutions23-26Universal Line 600x600 - 600x800 - 600x1000 Universal Line JUMBO 800x600 - 800x800 - 800x1000 Universal Line PCcase 600x80027-66EUROline 8 00x800 - 800x1000600x600 - 600x800 - 600x100067-88ECOline 8 00x800 - 800x1000600x600 - 600x800 - 600x100089-108RELAYrack Single frame, D=600 Double frame, D= 800, D=1000109-116PROline 600x450 - 600x560 - 600x(160+450) 117-130PROline Residential600x150 - 600x300131-136EUROline wall mounting600x450 - 600x600137-146ECOline wall mounting 600x450 - 600x600147-156WALL MOUNTING CABINETSSOHOline wall mounting 520x300 - 520x400 292x300 (10) SOHO Slimline157-166 167-168OTHER PRODUCTS Fiber Optic Boxes169-171PDU173-174Accessories Free standing accessories Wall mounting accessories175-215OUTDOOR ENCLOSURES217-224QUALITY CERTIFICATIONS225IP PROTECTION CLASS226 NOTES227-228 3. ServerMAX free standing Compatible with all EIA-310 compliant 19 equipment.All type of servers, brands will physically fit in ServerMAX server cabinet. Bottom plate has an extra perforated plate to prevent insects or mice from reaching the cables. Efficient passive air circulation Numbered U positions facilitate easy installation of rack mounted equipment.3 4. ServerMAX free standing 600x1000 - 800x1000ServerMAX free standing enclosure26U 36U42U47U42U47U600 x 1000*800 x 1000*ServerMAX protects your technological investments 19 HIGH QUALITY PRODUCTS COMPLIMENTS YOUR DECOR AND ENVIRONMENT SECURE AND STURDY EASY TO MAINTAIN: LARGEINNER VOLUME HIGH SECURITY FOR UNAUTHORIZED ACCESS STRONG PROTECTION AGAINST PHYSICAL DAMAGE EXCELLENT PASSIVE AIR VENTILATION* Please check drawing pages for cabinet sizes. 4 5. SERVERMAX FREE STANDING ENCLOSURES FORSTANDARD DIMENSIONS: Heights: 26U, 36U, 42U, 47U Width: 600 mm Depth: 1000 mm Heights: 42U, 47U Width: 780 mm Depth: 1000 mm LOAD CARRYING CAPACITY: 1000 kg600x1000 -800x1000COLOUR: RAL 9005 black RAL 7035 light grey STANDARDS: ISO 9001 : 2008 Quality Management Systems ISO 14001: 2004 Environmental Management System 19 mounting to IEC 297-1 EN 61587-1 mechanical structures (cabinets for electronic equipment) Overall cabinet dimensions for IEC 297-2KEY FEATURES Adjustable mounting depth: 19 mounting angles are adjustable in depth for various mounts for adjustable depth distance, please look at drawing pages. Bottom plate: fitted with an additional plate to prevent insects/vermin. If necessary a filter may be integrated to prevent dust infiltration. Bottom plate is complete with pre-punched removable sections: when airflow comes from the floor, these sections can be removed to provide efficient airflow inside the cabinet. Reversible doors: Front and rear doors may be detached and reversed to allow the door to open from the rear of the cabinet. Side doors are split in two: Front section used to access the cabinet; additional smaller section secured inside the cabinet. If additional ventilation is necessary it can be demanded as vented. The main inner strip of this panel is designed for the housing of cables and power strips. Numbered U positions facilitate easy installation for rack mounted equipment. Vertical mounting rails with square holes; adjustable in depth.5 6. ServerMAX free standing 600x1000 - 800x1000Optional plexi front door: May be used instead of vented front door. All in one: ServerMAX includes; casters, doors, ground studs, levelling feet, roof, bottom, side panels, C-rails, tilt bars, unloaded fan tray. Optimized depth: 1000 mm.Today and next generation installation of servers, for power distribution and cable management. 1000 mm is the optimum depth for comfort cabling, housing server and gaining space in data centers. Fixing to floor: ServerMAX can be easily fixed to the floor when necessary.A floor fixing kit is used for this purpose. Please see accessories for floor fixing kit. Efficient passive ventilation: New generation servers and networking products need adequate ventilation to operate efficiently. ServerMAX server cabinets provide6efficient passive ventilation because of its vented structure of front and rear doors. Front and rear doors have maximum perforation (%63) patterns for high-density cooling that meets or exceeds server manufacturers ventilation requirements. There is a fan tray on roof: Removable easily from the top.When the maintanence of fans are required, it can be reached directly from the top without touching any mounted device or servers. It is possible to attach a filter on top of the server fan unit. Generous cable access holes are provided in the roof and base. One on top, one on bottom holes are special ESTAP style cable entries; sliding type with rubber edges. 7. FEATURESQuick release side doors: During installation and while conducting routine maintenance of installed equipment, it is often advantageous to remove the side panels. Quick release slam latches and locks on the side panels allow for quick and easy access.600x1000 - 800x1000Anti-tilt bars: As standard, ServerMAX is fitted with 2 sliding type tilt bars to make the cabinet stable in weight center.Whenever the servers are moved out, tilt bars are drawn out to counter-balance the cabinets weight center.Double opening rear doors improve access and serviceability to rear of rack mounted equipment.The split rear doors help to maximize floor space. Only 390 mm for W=780 mm cabinets of clearance is required behind the enclosure to allow for door swing. D= 200 mm extention unit: If deeper equipment is loaded into ServerMAX cabinets requiring additional depth for cable radius, cable bundles, PDU housing etc, a D=200mm extension unit may be installed to ServerMAX cabinets: the rear door is removed and reinstalled onto the extension unit. (Please see diagrams on pages 18-19) Expansion: ServerMAX enclosures can be easily expanded to create complete rows of enclosures without side panels.With a proper baying kit (please see accessories) all cabinets are bayed easily and quickly. Welded: Bottom and roof of the cabinet is completely welded and a closed structure. Sturdy and rugged, it protects against physical elements like dust, insects. Lockable doors and side panels: Front and rear doors are lockable using a 3 point locking mechanism. A handle-style locking system provides increased security to prevent unauthorized access.All doors and side panels are only accessible with a key provided by ServerMAX. Stability: Heavy duty frame design, 2 mm mounting rails, angles, heavy duty type castor group provide 1000 kg load rating.7 8. ServerMAX free standing FEATURES 600x1000 - 800x1000Grounding: All parts are fitted with grounding studs to provide electrical continuity.Surface treatment: Fosfat coating, oil remove and passivation.Heavy duty vertical frames: Instead of 4ea. vertical profiles, ServerMAX cabinetsare 6ea.(3ea.in left+3ea.in right) main vertical profiles that gives extra stability for heavy loads.Material thicknesses: Roof, bottom, vertical main frames, 1,5 mm C-rails, 19 mounting angles, profiles and all frames are 2 mmthickness. Sturdy steel construction.More C rails: Instead of 6ea. there are 8 horizontal C rails in depth for extra stability. (42U, 47U)Paint: Electrostatic powder coating.Reinforced bottom: Bottoms are reinforced with horizontal profiles in width and depth for extra stability. Rounded aesthetic monoblok front door: Front door is a heavy duty type monoblock perforated and welded structure. Its shape is rounded in front to enhance the aesthetics.Easy to dismantle and assembly: The rigidly welded frame construction can be dismantled and assembled easily without any special tools.Thus, narrow doors, staircases and lifts are no problem. Special cable entry on top and bottom case: Bottom plate and top case have a special cable entry, completely closed, sliding type with rubber edges. Cables are entered and fixed. Housing for cabling: The cabinet itself has enough housing for vertical cable management at back. For 600x1000 cabinet, cable rings are used for cable management. For 780x1000 cabinets there are special vertical cable management panels of Ieft & right with cover plate for hiding and protecting the cables.These allow customers to easily route, manage and access large numbers of data cables even while an enclosure is loaded with rack mount equipment and bayed in a row. Power/energy distribution: Rear power distribution housing at back of the cabinet provide easy access to multiple receptacles.Vertical power distribution strips can easily be mounted in that space.This housing never interfere with equipment or takes any valuable U space.Providing increased accessibility to receptacles allows customers to support more power cords within the enclosure. Power strips are the length of cabinets: 26U, 36U, 42U, 47U.8 9. ADDITIONAL FEATURES FOR More Volume Width=780 mm: Provides more efficient cooling and more professional cabling ServerMAX Width=780 mm cabinet has all features mentioned before. Plus these additional features.800x1000 mmVertical cable management panels can be used at rear of the cabinetfor professional cabling and to hide the power cables. Extra Housing space for cabling and power distribution: This extra space provides housing for the vertical cable management panels and the vertical power strips.Left and right front panel: Front panels can be used to hide unwanted views of cables. If server cabinet is additionally used for networking in the front, cable management is needed: Estap cable rings can be used to attach this panel and secure cables.Access holes allow the patch cord to reach the rear of cabinet.9 10. ServerMAX free standing SELECTION STEPS FOR600x1000STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section in the catalogue, has a Main part number structure and Options sections. The below example explains how to select the right options for your needs. The product part number has the below structure for ServerMAX W=600 mm: Product range name+U height (HHU)The product options have the below structure: Colour option (MX)+Front door option (FX)+ Rear door option (RX)HOW TO SELECT THE OPTIONS Step 1 Please choose product part number. For example : SRV42U (Width=600 mm) Step 2 Please choose the colour from the table and place it after the part number. For example : SRV42U - M01 (MX=Look at the MX colour options on the next page) Step 3 Please choose the front door from the table and place it after MX colour. For example : SRV42U - M01 - F15 (FX= look at the FX front door options on the next page) Step 4 Please choose the rear door from the table and place it after FX front door option. For example : SRV42U - M01 - F15 - R07 (RX= look at the RX rear door options on the next page)10 11. PART NUMBER DEFINITION FOR 600x1000FX***MAIN PART NUMBER STRUCTURE SRV Product range ServerMAXF14**U height+SRVFront door options- HHU600HHU 26U 36USRV42U 47UHSRV:ServerMAX product range(W=600 mm) HHU:U height WD:600x1000 mmFront viewF15 R07*600OPTIONSMX - FX MX- RXFront door optionsColour options+FXM01F14**M02600Rear door options+RX R07*F15HHR07*MX: Colour options M01= RAL 9005 black M02= RAL 7035 light greyFront viewFront viewRX*** Rear door optionFX: Front door options F14**= Single opening, monoblock,welded, curved %63 perforated door, 3 point handled locking F15= Single opening, monoblock,welded, curved plexi glass door, 3 point handled lockingR07* 600RX: Rear door option q R07*= Double opening %63 perforated door with complete metal frame, 3 point handled lockingHBack view H= Enclosure height * R07 is the standard rear door. ** F14 is the standard front door.*** F14, F15 R07 can be used as front or rear door. 11 12. ServerMAX free standing TECHNICAL DRAWINGS FOR 600x1000 - 26U/36U/42U/47UR07* / ***F14** / *** F15***Exploded viewPart numberProduct definition (mm)U SizeWidth: overall (mm)Depth: overall (mm)Depth: max mounting profile (mm)Height: vertical mounting profile (mm)Height: without levelling feet (mm)Height: with casters (mm)ServerMAX cabinets 19 600 x 1000 mmSRV26U26U 600x1000 mm266001000740117912911338SRV36U36U 600x1000 mm366001000740162317351782SRV42U42U 600x1000 mm426001000740189020022049SRV47U47U 600x1000 mm476001000740211222242271*R07 is the standard rear door. ** F14 is the standard front door. *** F14, F15, R07 can be used as front or rear door.12 13. TECHNICAL DRAWINGS FOR600x1000 - 26U/36U/42U/47U565 200180(Min 795) 740HFront viewBottom viewMounting profile 100012600F14**(Min 25) 56140140906200(Min 158) 184600600F15HFront view47HSide viewBack viewFront view600 200R07*100020060030HTop view H= Enclosure heightIso viewFront view *R07 is the standard rear door. ** F14 is the standard front door.13 14. ServerMAX free standing PART NUMBER DEFINITION FOR800x1000STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section in the catalogue, has a Main part number structure and Options sections. The below example explains how to select the right options for your needs. The product part number has the below structure for ServerMAX W=780 mm: Product range name+U height (HHU)+ Width (WW, D=1000 mm)The product options have the below structure: Colour option (MX)+Front door option (FX)+Rear door option (RX)HOW TO SELECT THE OPTIONS Step 1 Please choose product part number. For example : SRV42U8 (Width=780 mm) Step 2 Please choose the colour from the table and place it after the part number. For example: SRV42U8 - M01 (MX= Look at the MX colour options on the next page) Step 3 Please choose the front door from the table and place it after MX colour. For example: SRV42U8 - M01 - F16 (FX= Look at the FX front door options on the next page) Step 4 Please choose the rear door from the table and place it after FX front door option. For example: SRV42U8 - M01 - F16 - R08 (RX= Look at the RX rear door options on the next page)14 15. PART NUMBER DEFINITION FOR800x1000FX***MAIN PART NUMBER STRUCTUREFront door options SRV - HHU - WW Product range ServerMAXSRVWidth & depth= 1000 mmU height+HHU+780842U SRVF16**WW47UHSRV:ServerMAX product range HHU:U height WW:Width (W=780 mm)OPTIONS MX - FX- RXFront door optionsColour optionsMXFront view+FXM01F16**M02F17R08*780780Rear door options+RXF17R08*HHR08*MX:Colour options M01= RAL 9005 black M02= RAL 7035 light greyFront viewFront viewRX*** Rear door optionFX:Front door options F16**= Single opening, monoblock, welded, curved %63 perforated door, 3 point handled locking F17= Single opening, welded, curved plexi glass door, 3 point handled lockingR08* 780RX: Rear door option R08*=Double opening %63 perforated door with complete metal frame, 3 point handled locking HBack view H= Enclosure height * R08 is the standard rear door. ** F16 is the standard front door.*** F16, F17 R08 can be used as front or rear door. 15 16. ServerMAX free standing TECHNICAL DRAWINGS FOR800x1000 - 42U/47UR08*/***F16**/*** F17***Exploded viewPart numberProduct definition (mm)U SizeWidth: overall (mm)Depth: overall (mm)Depth: max mounting profile (mm)Height: vertical mounting profile (mm)Height: without levelling feet (mm)Height: with casters (mm)ServerMAX free standing cabinets 19 780 x 1000 mmSRV42U842U 780x1000 mm427801000740189020022049SRV47U847U 780x1000 mm477801000740211222242271*R08 is the standard rear door. ** F16 is the standard front door. *** F16, F17, R08 can be used as front or rear door.16 17. TECHNICAL DRAWINGS FOR800x1000 - 42U/47U780745F16**(Min 762) 740H(Min 27) 44140140906200(Min 190) 19530028019 Mounting profileBottom view 100078012780Front viewHHSide view47Front viewF17Back viewFront view780780R08*200300Top view H= Enclosure height291000HIso viewFront view * R08 is the standard rear door. ** F16 is the standard front door.17 18. ServerMAX free standing TECHNICAL DRAWINGS FOR600x1000Technical drawing of extention unit D=200 mm for 600x1000 mm ServerMAX Top view after extention unit 60070200145Note: Depth of existing cabinet + 200 mm Exploded viewIso viewPart numberWidth: overall (mm)Depth: overall (mm)Height: without levelling feet (mm)Height: with casters (mm)SRV26U EXT62026U Extention unit D=200 mm, suitable for ServerMAX W=600 mm2660020012811328SRV36U EXT62036U Extention unit D=200 mm, suitable for ServerMAX W=600 mm3660020017261773SRV42U EXT62042U Extention unit D=200 mm, suitable for ServerMAX W=600 mm4260020019932040SRV47U EXT62018Product definition (mm)U SizeServerMAX 19 600 x 1000 mm extention unit47U Extention unit D=200 mm, suitable for ServerMAX W=600 mm4760020022152262 19. TECHNICAL DRAWINGS FOR 800x1000Technical drawing of extention unit D=200 mm for 780x1000 mm ServerMAX Top view after extention unit 78070200145Note: Depth of existing cabinet + 200 mmExploded view Iso viewPart numberProduct definition (mm)U SizeWidth: overall (mm)Depth: overall (mm)Height: without levelling feet (mm)Height: with casters (mm)ServerMAX 19 780 x 1000 mm extention unitSRV42U EXT82042U Extention unit D=200 mm, suitable for ServerMAX W=780 mm4278020019932040SRV47U EXT82047U Extention unit D=200 mm, suitable for ServerMAX W=780 mm477802002215226219 20. ServerMAX free standing TECHNICAL SPECIFICATIONSTESTS AND CERTIFICATIONS Environment EN61587-1/4.2, IEC60068-2-1, IEC60068-2-2, IEC60068-2-30, IEC60917 and IEC60297 Industrial environment EN61587-1/4.3, IEC60068-2-42, IEC60068-2-43 and IEC60068-2-49,IEC60068-2-1, IEC60917 and IEC60297 Statical mechanical structure load test EN61587-1 / 5.2.1, IEC60917 and IEC60297 Statical mechanical structure stability EN61587-1 / 5.2.2, IEC60917 and IEC60297 Dynamic load, vibration and mechanical stroke EN61587-1 / 5.3.1, EN61587-1 / 5.3.3, IEC60917, IEC60297, IEC62208 Grounding continuity EN61587-1 / 6.2, IEC60917 and IEC60297 Fire and flame resistance EN61587-1 / 6.3, IEC60917 and IEC60297 Corrosion ISO9227 and ASTM B 117-85, IEC60917 and IEC60297 IP protection degree IP20 accordingly EN61587-1 / 6.4, IEC60529, IEC60917 and IEC60297 Transportation ETS300019-1-2 Class 2.3 Storage ETS300019-1-1 Class 1.2 Security EN60950_LVD PURCHASED PRODUCT CERTIFICATIONS Sheet steel DIN EN 10130 99 Ereli DC- 01 6112, 7122, RoHS Electrostatic powder coating ISO 9001, ISO 2178, ISO 2813, ISO 6272, ISO 8130-5, ISO 8130-3, RoHS Fan ISO 9001, CE (89/336/EEC EMC, 73/23/EEC LVD), RoHS Glass ISO 9001, EN 12150 1: 2000 tempered and secure Fixings DIN 7985, DIN 965, DIN 7981, DIN 934, DIN 985, DIN 933, RoHS Castors TS EN 12530,TS EN 12532, RoHS Lock DIN 1743, DIN 53571, RoHS 20KEY FEATURESMain profile (framework) has an aesthetic structure which increases mechanical resistance, folded at an angle of 90 degrees and consisting of 4 bends for each profile. In total; 16 folds provide framework stability.Additionally, 2 piece vertical side panel divider profile provides additional resistance each with a 4 fold design; total of 8 fold additional support. In total ServerMax main profile framework consists of a 24 fold engineering design. Manufactured and tested to provide axial (x, y, z) resistance that meets EN 61587-1 / 5.2.1 and 5.2.2, and external impact resistance that meets EN 61587-1 / 5.3.3. Bottom and upper cases have a structure to increase the resistance and strength of the cabinet by monoblock bended, welded and profile-interlocking design. Profiles are manufactured to interlock bottom and upper cases with screws.The bottom case providing cable access is fitted with a sliding blanking access plate to prevent dust. A rubber edge on the cable access plate and sliding structure, it is possible to fix the cables and allows cables to be placed into the cabinet without any damage. Additional there are pre-punched knock outs for air distribution delivered from raised floor. Rear door in standard configuration is a double opening door which is removable and lockable. Integral locking is a 3 point locking system. Rear doors can be opened up to 215 degrees, are removable and lockable with handle type locking unit. Side panels have a structure that can be opened and removed with slam latch and key.They are lockable and removable. Side panels consist of a divider profile which creates 2 pieces side panels on each side. Original functional side panel is lockable and removable as mentioned above; the smaller side panel is fixed from inner side with screws. If additional ventilation is needed this panel can be replaced with a slotted / perforated one. Within this engineering construction, the original functional side panel becomes easy to carry while the divider profile provides better resistancy. Front doors are single opening, monoblock, welded, curved, %63 perforated in standard. Integral locking as 3 point locking system. For options please see the related diagrams and technical charts in pages 11-15. Front door can be opened up to 215 degrees, removable and lockable with handle type locking unit. Vented top panel housing with a dedicated space for ventilation, the fan module system allows easy installation of max. 6 fans from top. 19(inch) mounting angles (2ea. in front and 2ea. in rear) are part of cabinet interior configuration and adjustable in depth. Baying is possible for side by side applications without side panels. Levelling feet and integrated castor group are standard in shipping configuration. The cabinet meets EN 61587-1, IEC 60917, IEC 60297 standards, RoHS compliancy, Gost and TSE certified. Cabinets are manufactured in our factory which has ISO 9001: 2008 Quality Assurance System and our responsibility for enviroment with ISO 14001:2004 Environmental Management System. 21. TECHNICAL SPECIFICATIONSCustom number 85380000 / 85381000 / 853710990019 Packs of (ea.) 1 Shipping structure Assembled Mounting surface Stand alone Load carrying capacity (kg) 1000 Certification on product TSE, Gost Surface finish Electrostatic powder coated c/with surface treatment , 80 +/ - 5 micron paint thickness and tested according to IEC60068-21,2-2, 2-30,2-42, 2-43, 2-49, 2-11 STANDARD PRODUCT Standart colour RAL 7035, RAL 9005 Baying Possible with baying kit for side by side applications without side panels IP protection standard IP20 FRONT DOOR Single opening, monoblock, welded,curved, %63 perforated Front door construction Monoblock curved, welded construction Front door lock Handle type, 3 point locking Hinge system Spring loaded Door opening angle and swapping 215 degreeDoor opening angle and swapping 215 degree FRAMEWORKTop and bottom base units Solid Metal 2 mm Top and bottom base units construction Completely welded corner socket system Uprights Solid metal, 2 mm Uprights construction Tightly fixed into top and bottom base units 3 times folded 3 x 2 = 6 folds SIDE PANEL DIVIDER PROFILE Solid metal 2 mm Side panel construction Tightly fixed into top and bottom base units 4 times folded x 2 = 8 folds INTERIOR PARTS 19 mounting angles Solid metal, 2 mm 1 times folded for an L profile system U marking available 2 ea. at rear, 2 ea. at front Pre-configured as 19 Zinc plated, passivated, 8-12 micron Adjustable in depth Omega type support rails in depth Solid metal, 1,5 mm 3 times folded for W=600 mm cabinets Omega type folded for W=780 mm cabinets 3 ea. at left, 3 ea. at right26U and 36U 4 ea. at left, 4 ea. at right42U and 47USIDE PANEL Solid metal, 1 mm. Left and right (2ea.) Construction Lockable, removable c/with slam latches and lock Lock Barrel type lock unit, single point + slam latch (2ea) REAR DOOR Solid metal, 1 mm Rear door construction Double door opening, %63 perforated, lockable, removable Rear door lock Handled type lock unit, 3 point Hinge system Spring loadedFor CUSTOMIZED PRODUCTS rather than above options, please contact sales department.21 22. ServerMAX free standing accessories FREQUENTLY USED ACCESSORIES SELECTION CHART FOR SERVERMAXEstap has a wide range of accessories: Heavy duty fixed shelves, sliding shelves, fans, cooling units, vertical cable managements, cable rings, organisers, trays, plinths and so on... * See the other and part number definition on pages 173-213.* Please state colour choice in your orders. M01=RAL 9005 black and M02= RAL 7035 light greyFrequently used accessories selection tableServerMAX / Vertical PDU part numbers M44 24 AL IEC AMP MCBServerMAX / Cable management unit (suitable for 780x1000 Server Cabinets)Enclosure sizes* 800x100042UM44ORG42SRV47UM44ORG47SRVServerMAX / Cable management ringsPart number44x30K44RING0144x60K44RING021U44x110K44RING0370x160K44RING04ServerMAX / Floor fixing kitEnclosure sizes* 600x1000 800x1000 M44DPR0322* Please check drawing pages for cabinet sizes.M44DPR04 23. Data Center solutionsData center solutions which is mission critical, require reliable, flexible and scalable infrastructures alongside guarantied high performance. ESTAP OFFERS energy efficient MANAGABLE, MEASURABLE AND SCALABLE SOLUTIONS TO DATA CENTER PROJECTS.23 24. Data CentersolutionsMAIN FEATURES DCMax data center server cabinets are designed to provide hot corridor, cold corridor and its containment structure, which has been widely used in enterprise datacenters. Design criteria serves to provide: Maximum performance for cooling of IP20 and IP55 solutions Wide range of cabinet sizes and accessories H=42/47U W=600/800 mm D=1000/1100/1200 mm Load capacity= 1500 kg. DCMax structure is suitable for carrying heavy loads and is seismic tested to 1000 kg (BELLCORE GR-63-CORE ZONE 4, NEBS) Maximum inner space for servers Minimum environmental space requirement Professional cable management Heavy duty structure Compability with all vendors servers High technical performance, grounding continuity Power / energy management Controllable and reliable security with monitoring Aesthetic and professional design19 OPEN FRAME CABLING CABINET, IP20 Estap System Rack cabinet series offers an ideal solution for the data center which include high density cabling and need effective cooling. Its heavy-duty structure is suitable to house the component of the network backbone.24HOT & COLD CORRIDOR APPLICATIONS Estap datacenter cooling solution offers real and energy efficient cooling with its wide product range such as water chilled sidecoolers, in-row coolers, heat removal units, cold corridor containment and so on. 25. Data Center solutionsLCD CONSOLES & KVM The high quality KVM switch is ideal for use in small to middle sized server rooms and provides direct connection to many servers. Estap consoles with/without integrated KVM are a space saving and functional solution for a comfortable connection to PCs, servers KVM installations in a 1U rack-mounting area.REMOTE MONITORING SYSTEM Supplies real time monitoring and management solution for data centers to secure flawless operation with high resilien.POWER DISTRIBUTION UNITS (PDU) Estap managed IP PDUs provide reliable power distribution and monitoring of individual outlets to data centers, for both Blade servers. Designed for high density, mission critical server applications, Estap IP PDU range offers an excellent solution to scale electrical power budgets and fight against the inevitable rise of electrical energy costs in the data center business.25 26. Data CentersolutionsData Center solutionsESTAP Data center COOLING SOLUTIONS Estap data center IT cooling solution ensures maximum IT availability at minimum running cost. The power usage effectiveness in the data centers indicates that approximately %30 of the total incoming power is utilised by cooling and cooling related equipment.FEATURES Cold corridor Liquid / gas cooling High cooling capacity Easy mounting and maintenanceESTAP DATA CENTER COOLING SOLUTIONS Hot corridor26In Row coolers are utilised. To serve for cooling and/or enhancing the cooling capacity of a cold corridor containment. Heat rejection can be handled by an existing chilled water system: The modular solution serve scalable cooling capacity growth. 27. Universal Line free standing Provides unique features for system designers, installers and network managers. Suitable for office, equipment room and cabling closet installations Exceptionally sturdy and strong Highly cost-effective and assembly-friendly solutions for numerous applications Multiple cable entry points provide maximum versatility Delivered as assembled and side by side mounting is possible27 28. Universal Line free standing enclosures 600x600 - 600x800 - 600x1000 - 800x600 - 800x800 - 800x1000Universal Line free standing enclosures16U 20U22U 26U 32U 26U 36U42U36U39U42U44U47U600 x 600*600 x 800*600 x 1000*47UUniversal Line JUMBO free standing enclosures32U42U36U39U42U44U47U800 x 1000*47UUniversal Line PCcase36U600 x 800*Highly cost-effective and assembly-friendly solutions for numerous applications* Please check drawing pages for cabinet sizes.28800 x 600*800 x 800* 29. UNIVERSAL LINE ENCLOSURES FORSTANDARD DIMENSIONS: Heights:16U, 20U, 22U, 26U 32U, 36U, 39U, 42U, 44U, 47U Width: 600 mm Depth: 600 mm - 780 mm Heights: 26U, 36U, 42U, 47U Width: 600 mm Depth: 1000 mm LOAD CARRYING CAPACITY:600 kg600x600 - 600x800- 600x1000COLOUR: RAL 9005 black RAL 7035 light grey STANDARDS: ISO 9001: 2008 Quality Management Sytem ISO 14001: 2004 Environmental Management System 19 mounting to IEC 297-1 EN 61587-1 mechanical structures (cabinets for electronic equipment) Overall cabinet dimensions for IEC 297-2KEY FEATURES The Universal Line free standing cabinets are suitable for office, equipment room, housing server and cabling closet installations. Attention to style with attractive colours black RAL 9005 and light grey RAL 7035 and smoked glass door reinforced with vertical left and right metal frames means that cabinets can be deployed in the most demanding of office environments where appea counts. However, Universal Line are an exceptionally sturdy and strong cabinet enabling usage for all applications. Front door frames are available with orange decorative stripe. The Universal Line offers a highly cost-effective and assembly-friendly solution for numerous applications in the field of network technology and electronics.The Universal Line is highly configurable to the end users requirements and provides unique features to benefit system designers, installers and network managers. Standard cabinet is completely assembled and delivered as a single enclosure. Side by side mounting is also possible when side panels are not used; baying kits to be added. The rigid welded frame construction can be disassembled and assembled easily without any special tools.Thus narrow doors, staircases and elevators are no problem.29 29 30. Universal Line free standing enclosuresUniversal Line free standing enclosures offer a wide range of options.30 31. UNIVERSAL LINE FREE STANDING ENCLOSURES FOR 600x600 - 600x800 - 600x1000EASY TO ACCESS Front door Features a full-length smoked and shatterproof glass door with decorative accent stripe reinforced with left/right metal frames and integral locking mechanism. Side doors Lockable, removable, complete with slam latches and barrel type locks.19 mounting angles (front/2ea and back/2ea) allow for flexible configuration and are adjustable in depth. C rails 3 fold 1,5 mm thickness to increase the stability of equipment . Levelling feet included as a standard feature.Rear door Lockable, removable lock. Secure, locking front and back doors with spring loaded hinges offer best accessibility even when connecting the cabinets. The door hinge is easily swapped from one side to the other to change the direction the door opens. Giving you 4-way access to equipment. Front and rear door can be replaced giving you flexibility for different installations. CABLE ACCESS Multiple cable entry points provide maximum versatility. There is a rubber edge sliding cover mechanism that protects and fix the cables.There is a brush on the rear panel that can be positioned on top or bottom (brush entry available on height of 26 U and above) CONSTRUCTION Rigid welded frame construction in steel sheet, rapidly disassembled with 4 screws per corner. Corners of base has welded sockets that tightly fixed into the columns give maximum stability. Frames are made with a 24-fold design for increased stability. Vented Pagoda style top cover with built-in space for available top mount ventilation fan system providing protection against dust flow from the top, additionally this causes a chimney effect to provide passive air flow via convection.31 32. Universal Line free standing SELECTION STEPS FOR600x600 - 600x800STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section in the catalogue, has a Main part number structure and Options sections. The below example explains how to select the right options for your needs. The product part number has the below structure: P roduct range name+U height (HHU)+Width&Depth (WD)+Rear door option (RX)The product options have the below structure: C olour option (MX)+Front door option (FX)HOW TO SELECT THE OPTIONS Step 1 Please choose product part number. For example: CKR42U66 Step 2 Please choose the colour from the table and place it after the part number. For example: CKR42U66 - M02 (MX=Look at the MX colour options on the next page) Step 3 Please choose the front door from the table and place it after MX colour. For example: CKR42U66 - M02 - F01 (FX= Look at the FX front door options on the next page) Step 4 Please choose the rear door from the table and place it after FX front door option. For example: CKR42U66 - M02 - F01 - R02 (RX= Look at the RX rear door options on the next page)32 33. PART NUMBER DEFINITION FOR600x600 - 600x800FXMAIN PART NUMBER STRUCTURE CKR Product range Universal LineF01*Width & DepthU height+CKRFront door options- HHU - WD+HHUF02600600WD16U 20U 22U 26U 32UH6636UCKRH6839U 42U 44UFront view47UFront viewF03CKR:Universal Line free standing product range HHU:U height WD:Width and depthF04600600 OPTIONS MX -- RX**Front door optionsColour optionsMXFX+FXRear door options+HHRXM01F01*R01M02F02R02F03* F01 is the standard front door. **RX - R01 is standard rear door for 22U and below, is optional door for 26U and above R02 is standard rear door for 26U and above with 2 brushed cable access partFront viewRX** Rear door options 300R02 55MX: Colour options M01= RAL 9005 black M02= RAL 7035 light grey FX: Front door options F01*= Single opening shatter proof glass door with left and right metal frame slotted, single point handled locking F02= Single opening shatter proof glass door with complete metal frame slotted, single point handled locking F03= Single opening solid metal door, single point handled locking F04= Single opening %63 perforated door with complete metal frame slotted, single point handled locking RX**: Rear door options R01= Single opening solid metal rear door with barrel type single point lock unit for 22U and below R02= Single opening solid metal rear door with barrel type single point lock unit with brushed cable entry, for 26U and aboveFront viewR01 60055F04H= Enclosure height300 Back viewBack view33 34. Universal Line free standing TECHNICAL DRAWINGS FOR600x600 - 16U/20U/22UR01**F01*F02F03F04Exploded viewPart numberProduct definition (mm)U SizeWidth: overall (mm)Depth: overall (mm)Depth: max mounting profile (mm)Height: vertical mounting profile (mm)Height: without levelling feet (mm)Height: with levelling feet (mm)Height: with casters (mm)Universal Line free standing cabinets 19 600 x 600 mmCKR16U6616U 600x60016600600390715865880945CKR20U6620U 600x60020600600390890104210571122CKR22U6622U 600x60022600600390980113111461211* F01 is the standard front door. ** R01 is the standard rear door for 22U and below.34 35. TECHNICAL DRAWINGS FOR 600x600 - 16U/20U/22U600395F01* (Min 30) 111300(Min 520) 390478200H(Min 45) 95Front viewBottom view60019F02Mounting profileH600600 Front view600F03HSide viewFront viewHBack viewFront view600600600F04HTop view H= Enclosure heightIso viewFront view * F01is the standard front door.35 36. Universal Line free standing TECHNICAL DRAWINGS FOR600x800 - 16U/20U/22UR01**F01*F02F03F04Exploded viewPart numberProduct definition (mm)U SizeWidth: overall (mm)Depth: overall (mm)Depth: max mounting profile (mm)Height: vertical mounting profile (mm)Height: without levelling feet (mm)Height: with levelling feet (mm)Height: with casters (mm)Universal Line free standing cabinets 19 600 x 780 mmCKR16U6816U 600x78016600780555715865880945CKR20U6820U 600x78020600780555890104210571122CKR22U6822U 600x78022600780555980113111461211* F01 is the standard front door. ** R01 is the standard rear door for 22U and below.36 37. TECHNICAL DRAWINGS FOR600x800 - 16U/20U/22U600F01*395200(Min 30) 130300658(Min 701) 555H(Min 45) 91Front view600F0219Bottom viewMounting profileH600780 Front view H600F03HHFront viewSide viewBack viewFront view600600780F04HTop view H= Enclosure heightIso viewFront view * F01is the standard front door.37 38. Universal Line free standing TECHNICAL DRAWINGS FOR 600x600 - 26U/32U/36U/39U/42U/44U/47UR02**F01*F02 F03 F04Exploded viewPart numberProduct definition (mm)U SizeWidth: overall (mm)Depth: overall (mm)Depth: max mounting profile (mm)Height: vertical mounting profile (mm)Height: without levelling feet (mm)Height: with levelling feet (mm)Height: with casters (mm)Universal Line free standing cabinets 19 600 x 600 mmCKR26U6626U 600x600266006003901160130913241389CKR32U6632U 600x600326006003901422157615911656CKR36U6636U 600x600366006003901603175417691834CKR39U6639U 600x600396006003901735188719021967CKR42U6642U 600x600426006003901868202120362101CKR44U6644U 600x600446006003901960211021252190CKR47U6647U 600x600476006003902093224422592324* F01 is the standard front door. ** R02 is the standard rear door for 26U and above.38 39. TECHNICAL DRAWINGS FOR 600x600 - 26U/32U/36U/39U/42U/44U/47U600F01*395H(Min 520) 390 (Min 45) 95478200(Min 30) 111300Bottom viewFront viewF0260019Mounting profile 600300 55600HFront view 600F0355HFront viewH300 Back viewSide view600 Front viewF04600600HTop view H= Enclosure heightIso view Front view * F01 is the standard front door.39 40. Universal Line free standing TECHNICAL DRAWINGS FOR600x800 - 26U/32U/36U/39U/42U/44U/47UR02**F01*F02 F03 F04Exploded viewPart numberProduct definition (mm)U SizeWidth: overall (mm)Depth: overall (mm)Depth: max mounting profile (mm)Height: vertical mounting profile (mm)Height: without levelling feet (mm)Height: with levelling feet (mm)Height: with casters (mm)Universal Line free standing cabinets 19 600 x 780 mmCKR26U6826U 600x780266007805551160130913241389CKR32U6832U 600x780326007805551422157615911656CKR36U6836U 600x780366007805551603175417691834CKR39U6839U 600x780396007805551735188719021967CKR42U6842U 600x780426007805551868202120362101CKR44U6844U 600x780446007805551960211021252190CKR47U6847U 600x780476007805552093224422592324* F01 is the standard front door. ** R02 is the standard rear door for 26U and above.40 41. TECHNICAL DRAWINGS FOR 600x800 - 26U/32U/36U/39U/42U/44U/47U395600F01*200(Min 30) 130300(Min 45) 91658(Min 701) 555HBottom viewFront viewF0260019Mounting profile 780300 55600HFront view 600F0355HH300 Front viewSide viewBack view600 Front viewF04780600HTop view H= Enclosure heightIso view Front view * F01is the standard front door.41 42. Universal Line free standing SELECTION STEPS FOR 600x1000STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section in the catalogue, has a Main part number structure and Options sections. The below example explains how to select the right options for your needs. The product part number has the below structure: P roduct range name+U height (HHU)+Width&Depth (WD)+Rear door option (RX)The product options have the below structure: C olour option (MX)+Front door option (FX)HOW TO SELECT THE OPTIONS Step 1 Please choose product part number. For example: CKR42U6100 Step 2 Please choose the colour from the table and place it after the part number. For example: CKR42U6100 - M02 (MX=Look at the MX colour options on the next page) Step 3 Please choose the front door from the table and place it after MX colour. For example: CKR42U6100 - M02 - F01 (FX= Look at the FX front door options on the next page) Step 4 Please choose the rear door from the table and place it after FX front door option. For example: CKR42U6100 - M02 - F01 - R02 (RX= Look at the RX rear door options on the next page)42 43. PART NUMBER DEFINITION FOR 600x1000FXMAIN PART NUMBER STRUCTURE CKR Product range Universal LineCKRFront door options- HHU - WD+HHUF05*Width & DepthU height+F06600600WD26U 610036UCKR42U 47UHCKR:Universal Line free standing product range HHU:U height WD:Width and depthHFront viewFront viewF07 OPTIONSF08600600MX - FX - RX Front door optionsColour optionsMX+FXRear door options+RXF05*R01M02F06R02*F07R03F08F04MX: Colour options M01= RAL 9005 black M02= RAL 7035 light grey FX: Front door options F05*= Single opening tempered proof glass door with left and right metal frame slotted, single point handled locking F06= Single opening tempered proof glass door with complete metal frame slotted, single point handled locking F07= Single openingsolid metal door, single point handled locking F08= Single opening %63 perforated door with complete metal frame slotted, single point handled locking RX: Rear door options R01= Single opening solid metal rear door with barrel type, single point lock unit R02*= Single opening solid metal rear door with barrel type, single point lock unit, brushed cable entry on top and bottom R03= Double opening % 63 perforated rear door with complete frame, 3 point handled locking F04= Single opening %63 perforated door with complete metal frame slotted, single point handled lockingHHFront viewFront viewRX Rear door optionsR02* 300R03R01F0455M01Back viewBack viewBack viewBack viewH= Enclosure height* F05 and R02 are the standard doors 43 44. Universal Line free standing TECHNICAL DRAWINGS FOR 600x1000 - 26U/36U/42U/47UR01 R03 F04 R02**F05*F06 F07 F08Exploded viewPart numberProduct definition (mm)U SizeWidth: overall (mm)Depth: overall (mm)Depth: max mounting profile (mm)Height: vertical mounting profile (mm)Height: without levelling feet (mm)Height: with levelling feet (mm)Height: with casters (mm)Universal Line free standing cabinets 19 600 x 1000 mmCKR26U610026U 600x10002660010007401175130913241389CKR36U610036U 600x10003660010007401620175417691834CKR42U610042U 600x10004260010007401889202120362101CKR47U610047U 600x10004760010007402110224422592324* F05 is the standard front door. ** R02 is the standard rear door for 26U and above.44 45. TECHNICAL DRAWINGS FOR 600x1000 - 26U/36U/42U/47U600395F05*200(Min 30) 150300878(Min 921) 740HFront view (Min 45) 106Bottom view 100019Mounting profile 300 55600F06600HFront view 600F0755HFront viewH300 Back viewSide view600Front viewF081000600HTop view H= Enclosure heightIso view Front view * F05 is the standard front door.45 46. Universal Line free standing TECHNICAL SPECIFICATIONSTESTS AND CERTIFICATIONS Environment EN61587-1 / 4.2, IEC60068-2, IEC60068-2-2, IEC60068-2-30, IEC60917 and IEC60297 Industrial environment EN61587-1 / 4.3, IEC60068-2-42, IEC60068-2-43 and IEC60068-2-49, IEC60068-2-I, IEC60917 and IEC60297 Statical mechanical structure load test EN61587-1 / 5.2.1, IEC60917 and IEC60297 Statical mechanical structure stability EN61587-1 / 5.2.2, IEC60917 and IEC60297 Dynamic load, vibration and mechanical stroke EN61587-1 / 5.3.1, EN61587- / 5.3.3, IEC60917, C60297, IEC62208 Grounding continuity EN61587-1 / 6.2, IEC60917 and IEC60297 Fire and flame resistance EN61587-1 / 6.3, IEC60917 and IEC60297 Corrosion ISO9227 and ASTM B 117-85, IEC60917 and IEC60297 IP protection degree IP20 accordingly EN61587-1 / 6.4, IEC60529, IEC60917 and IEC60297 Transportation ETS300019-1-2 Class2.3 Storage ETS300019-1-1 Class1.2 Security EN60950_LVD PURCHASED PRODUCT CERTIFICATIONS Sheet steel DIN EN 10130 99 Ereli DC-01 6112 , 7122, RoHS Electrostatic powder coating ISO 9001, ISO 2178, ISO 2813, ISO 6272, ISO 8130-5, ISO 8130-3, RoHS Fan ISO 9001, CE (89/336/EEC EMC, 73/23/EEC LVD), RoHS Glass ISO 9001, EN 12150 1: 2000 tempered and secure Fixings DIN 7985, DIN 965, DIN 7981, DIN 934, DIN 985, DIN 933, RoHS Castors TS EN 12530,TS EN 12532, RoHS Lock DIN 1743, DIN 53571, RoHS 46KEY FEATURESMain profile (framework) has an aesthetic structure which increases mechanical resistance, folded at an angle of 45 degrees and consisting of 6 bends for each profile. In total; 24 folds provide framework stability.Tested to provide (x, y, z) axis resistance that meets EN 61587-1/5.2.1 and 5.2.2 and external impact resistance that meets EN 615871/5.3.3. Bottom and upper case have a structure which increases resistance and strength of cabinet by mono-block bended, welded and profile-interlocking design. Profiles are manufactured to interlock bottom and upper case with screws. Cable access at bottom case has a sliding type blanking access plate that would block dust inlet. A rubber edge on the cable access plate with sliding structure, allows fixing of cables into the cabinet without any damage. Rear door is manufactured with 2 cable access parts 1 ea. with brush on top 1 ea. on bottom for 26 U and above sizes*. Rear door in standard configuration is a single opening door which is removable and lockable. For options please see the related diagrams and technical charts on pages 33-43. Side panels have a structure that can be opened and removed with slam latch and key and are lockable and removable. Front doors are a framed glass structure which is tempered, anti-static, secure and smoked glass (4 mm thickness) with a decorative stripe, according to EN 12150-1:2000 standard.Front door in standard configuration has left and right metal frame structure with high density polyurethane adhesive and screw. For front door options please see the related diagrams and technical charts on pages 33-43. Front door can be opened to 125 degrees, removable and lockablewith handle type locking unit. Pagoda style vented top panel with a dedicated space of ventilation fan module system allows easy installation of max. 4fans. 19(inch) mounting angles (2ea. in front and 2ea. in rear) are part of the cabinet interior configuration and adjustable in depth. Baying is possible for side by side applications without side panels. Levelling feet are standard in shipping configuration. The cabinet meets EN 61587-1, IEC 60917, IEC 60297 standards, RoHS compliancy, Gost and TSE certified. Cabinets are manufactured in our factory which has ISO 9001: 2008 Quality Assurance System and our responsibility for environment withISO 14001:2004 Environmental Management System. * Please see related diagrams to define the difference of rear door design between up to 26U and above 26U 47. TECHNICAL SPECIFICATIONSCustom number 85380000 / 85381000 / 853710990019 Shipping structure Assembled Mounting type Stand alone Load carrying capacity (kg) 600 Certification on product TSE, Gost Surface finish Electrostatic powder coated c/with surface treatment , 80 +/ - 5 micron paint thickness and tested according to IEC60068-21,2-2, 2-30,2-42, 2-43, 2-49, 2-11 STANDARD PRODUCT Standard colour RAL 7035, RAL 9005 Standard stripe colour Orange IP protection standard IP20 FRONT DOOR Shatterproof glass with left and right metal frame Glass 4 mm thickness full-length smoked, shatterproof, tempered, secure Front door construction Single door opening Front door lock Handle type, single point locking Adhesive material High density polyurethane DIN 53479, DIN 53505 Hinge system Spring loaded Door opening angle and swapping 125 degree, possible to swap one side to the other SIDE PANEL Solid metal, 1 mm left and right (2ea.) Side panel construction Lockable, removable c/with slam latches and lock Side panel lock Barrel type lock unit, single point + Slam latch (2ea)REAR DOOR Solid metal, 1 mm Rear door construction Single opening, solid metal with brushed cable entry on top and bottom. Rear door lock Barrel type lock unit, single point Hinge system Spring loaded Door opening angle and swapping 125 degree, possible to swap one side to the other TOP COVER Solid metal 1 mm Top cover construction Pagoda type structure provides efficient air removal FRAMEWORKTop and bottom base units Solid metal 1,5 mm Top and bottom base units construction Completely welded corner socket system Uprights Solid metal, 1,5 mm Uprights construction Tightly fixed into top and bottom base units 6 times foldedINTERIOR PARTS19 mounting angles Solid metal, 1,5 mm 3 times folded 600x600, 600x780 / 1 time folded for 600x1000 U marking available 2 ea. at rear, 2 ea. at front Pre-configured as 19 Zinc plated, passivated, 8-12 micron. Adjustable in depth C type support rails in depth Solid metal, 1,5 mm 3 times folded, 2 ea. at left , 2 ea. at right up to 26U 3 ea. at left , 3 ea. at right26U and higher OPTIONS For front and rear door options, please look at pages 33-43.For CUSTOMIZED PRODUCTS rather than above options, please contact sales department.47 48. Universal Line JUMBOfree standingSELECTION STEPS FOR 800x800STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section in the catalogue, has a Main part number structure and Options sections. The below example explains how to select the right options for your needs. The product part number has the below structure: P roduct range name+U height (HHU)+Width&Depth (WD)+Rear door option (RX)The product options have the below structure: C olour option (MX)+Front door option (FX)HOW TO SELECT THE OPTIONS Step 1 Please choose product part number. For example: CKR42U88 Step 2 Please choose the colour from the table and place it after the part number. For example: CKR42U88 - M02 (MX=Look at the MX colour options on the next page) Step 3 Please choose the front door from the table and place it after MX colour. For example: CKR42U88 - M02 - F09 (FX= Look at the FX front door options on the next page) Step 4 Please choose the rear door from the table and place it after FX front door option. For example: CKR42U88 - M02 - F09 - R06 (RX= Look at the RX rear door options on the next page)48 49. PART NUMBER DEFINITION FOR 800x600 - 800x800FXMAIN PART NUMBER STRUCTURE CKR - HHU - WD Product range Universal LineCKRWidth & DepthU height+HHU+F09*WD32UF107807808636UCKRFront door options8839UHH42U 44U 47UCKR:Universal Line free standing product range HHU:U height WD:Width and depthFront viewF11Front viewF12***780R04**780780 OPTIONSMX - FX - RX Front door optionsColour optionsMX+FXRear door options+HHHRXM01F09*R04**M02F10R05F11R06*F12***F12***Front view* F09 and R06 are the standard doors. ** R04 can be usable as front door also. *** F12 used as rear door as well.Front viewRXR04**Rear door optionsR04**R06* 55300H55MX:Colour options M01= RAL 9005 black M02= RAL 7035 light grey FX: Front door options F09*= Double opening tempered proof glass door with left and right metal frame slotted, two point barrel type locking F10= Single opening tempered proof glass door with complete metal frame slotted, single point handled locking F11= Single opening solid metal door, single point handled locking F12***= Single opening %63 perforated door with complete metal frame slotted, single point handled locking R04**= Double opening %63 perfore door with complete metal frame, 3 point handled locking RX:Rear door options R06*= Double opening complete metal door with brushed cable entry, barrel type single point lock unit. R04**= Double opening %63 perforated doorwith complete metal frame, 3 point handled locking R05= Single opening solid metal rear door with barrel type, single point lock unit F12***= Single opening %63 perforated door with complete metal frame slotted, single point handled lockingFront view300Back viewR05Back viewBack viewF12***Back viewH= Enclosure height49 50. Universal Line JUMBO TECHNICAL DRAWINGS FOR800x600 - 32U/36U/39U/42U/44U/47UF12*** R05 R04** R06*F09* F10 F11 R04** F12***Exploded viewPart numberProduct definition (mm)U SizeWidth: overall (mm)Depth: overall (mm)Depth: max mounting profile (mm)Height: vertical mounting profile (mm)Height: without levelling feet (mm)Height: with levelling feet (mm)Height: with casters (mm)Universal Line JUMBO cabinets 19 780 x 600 mmCKR32U8632U 780x600327806003651422157615911656CKR36U8636U 780x600367806003651603175417691834CKR39U8639U 780x600397806003651735188719021967CKR42U8642U 780x600427806003651868202120362101CKR44U8644U 780x600447806003651960211021252190CKR47U8647U 780x600477806003652093224422592324* F09 and R06 are the standard doors. ** R04 is usable as front door also. *** F12 is usable as rear door also.50 51. TECHNICAL DRAWINGS FOR 800x600 - 32U/36U/39U/42U/44U/47UF09*515F10780300 478(Min 408) 36555H(Min 138) 141200780(Min 50) 9030019Bottom viewFront viewMounting profile780Front viewF11 780300 55600HHHHFront viewF12 55780Front view300Side viewHBack viewFront view780R0455 300 600780HTop view H= Enclosure heightIso viewFront view * F09 is the standard door.51 52. Universal Line JUMBO TECHNICAL DRAWINGS800x800 - 32U/36U/39U/42U/44U/47UF12*** R05 R04** R06*F09* F10 F11 R04** F12***Exploded viewPart numberProduct definition (mm)U SizeWidth: overall (mm)Depth: overall (mm)Depth: max mounting profile (mm)Height: vertical mounting profile (mm)Height: without levelling feet (mm)Height: with levelling feet (mm)Height: with casters (mm)Universal Line JUMBO cabinets 19 780 x 780 mmCKR32U8832U 780x780327807805501422157615911656CKR36U8836U 780x780367807805501603175417691834CKR39U8839U 780x780397807805501735188719021967CKR42U8842U 780x780427807805501868202120362101CKR44U8844U 780x780447807805501960211021252190CKR47U8847U 780x780477807805502093224422592324* F09 and R06 are the standard doors. ** R04 is usable as front door also *** F12 is usable as rear door also.52 53. TECHNICAL DRAWINGS FOR 800x800 - 42U/47U515 300 (Min 40) 95F10 780(Min 720) 550780HH(Min 130) 13165830085300F09*Front view19Bottom viewMounting profileFront viewF11 780780300 55780HHHFront viewF12 55780Front view300Side viewBack view H780 Front viewR0455780300780HTop view H= Enclosure heightIso viewFront view * F09 is the standard front door.53 54. Universal Line JUMBO free standing SELECTION STEPS FOR 800x1000STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section in the catalogue, has a Main part number structure and Options sections. The below example explains how to select the right options for your needs. The product part number has the below structure: P roduct range name+U height (HHU)+Width&Depth (WD)+Rear door option (RX)The product options have the below structure: C olour option (MX)+Front door option (FX)HOW TO SELECT THE OPTIONS Step 1 Please choose product part number. For example: CKR42U8100 Step 2 Please choose the colour from the table and place it after the part number. For example: CKR42U8100 - M02 (MX=Look at the MX colour options on the next page) Step 3 Please choose the front door from the table and place it after MX colour. For example: CKR42U8100 - M02 - F09 (FX= Look at the FX front door options on the next page) Step 4 Please choose the rear door from the table and place it after FX front door option. For example: CKR42U8100 - M02 - F09 - R06 (RX= Look at the RX rear door options on the next page)54 55. PART NUMBER DEFINITION FOR 800x1000FXMAIN PART NUMBER STRUCTURE CKR - HHU - WDProduct range Universal LineCKRFront door optionsWidth & DepthU height+HHU+WDHHFront view 78047UCKR:Universal Line product range HHU:U height WD:Width and depth OPTIONSF10780810042UCKRF09*F11Front viewF12***780R04**780780MX - FX - RX Front door optionsColour optionsMX+FXRear door options+HRXM01F09*R04**M02F10R05F11R06*F12HF12***Front viewFront viewFront viewR04**RXMX:Colour options M01= RAL 9005 black M02= RAL 7035 light grey FX: Front door options F09*= Double opening tempered proof glass door with left and right metal frame slotted, two point barrel type locking F10= Single opening tempered proof glass door with complete metal frame slotted, single point handled locking F11= Single opening solid metal door, single point handled locking F12***= Single opening %63 perforated door with complete metal frame slotted, single point handled locking R04**= Double opening %63 perforated door with complete metal frame, 3 point handled locking RX:Rear door options R05= Single opening solid metal rear door with barrel type, single point lock unit R04**= Double opening %63 perforated doorwith complete metal frame, 3 point handled locking R06*= Double opening complete metal door with brushed cable entry, barrel type single point lock unit. F12***= Single opening %63 perforated door with complete metal frame slotted, single point handled lockingRear door options* F09 and R06 are the standard doors ** R04 is usable as front door also. *** F12 is usable as rear door also.R04**R06* 5530055H300Back viewR05Back viewBack viewF12***Back viewH= Enclosure height55 56. Universal Line JUMBO TECHNICAL DRAWINGS FOR800x1000 - 42U/47UF12*** R05 R04** R06*F09* F10 F11 R04** F12***Exploded viewPart numberProduct definition (mm)U SizeWidth: overall (mm)Depth: overall (mm)Depth: max mounting profile (mm)Height: vertical mounting profile (mm)Height: without levelling feet (mm)Height: with levelling feet (mm)Height: with casters (mm)Universal Line JUMBO cabinets 19 780 x 1000 mmCKR42U810042U 780X10004278010007401889202120362101CKR47U810047U 780X10004778010007402110224422592324* F09 and R06 are the standard doors. ** R04 is usable as front door also. *** F12 is usable as rear door also.56 57. TECHNICAL DRAWINGS FOR 800x1000 - 42U/47U515 300 (Min 26) 120F10780780(Min 852) 740 (Min 118) 13687830085300F09*Bottom viewHHFront view19Mounting profileFront viewF11 780780100055300HHHFront view55F12 780300Front viewSide viewBack viewH780 Front viewR04 780100030055HTop view H= Enclosure heightIso viewFront view * F09 is the standard front door.57 58. Universal Line JUMBO TECHNICAL SPECIFICATIONSTESTS AND CERTIFICATIONS Environment EN61587-1 / 4.2, IEC60068-2, IEC60068-2-2, IEC60068-2-30, IEC60917 and IEC60297 Industrial environment EN61587-1 / 4.3, IEC60068-2-42, IEC60068-2-43 and IEC60068-2-49, IEC60068-2-I, IEC60917 and IEC60297 Statical mechanical structure load test EN61587-1 / 5.2.1, IEC60917 and IEC60297 Statical mechanical structure stability EN61587-1 / 5.2.2, IEC60917 and IEC60297 Dynamic load, vibration and mechanical stroke EN61587-1 / 5.3.1, EN61587- / 5.3.3, IEC60917, C60297, IEC62208 Grounding continuity EN61587-1 / 6.2, IEC60917 and IEC60297 Fire and flame resistance EN61587-1 / 6.3, IEC60917 and IEC60297 Corrosion ISO9227 and ASTM B 117-85, IEC60917 and IEC60297 IP protection degree IP20 accordingly EN61587-1 / 6.4, IEC60529, IEC60917 and IEC60297 Transportation ETS300019-1-2 Class2.3 Storage ETS300019-1-1 Class1.2 Security EN60950_LVD PURCHASED PRODUCT CERTIFICATIONS Sheet steel DIN EN 10130 99 Ereli DC-01 6112 , 7122, RoHS Electrostatic powder coating ISO 9001, ISO 2178, ISO 2813, ISO 6272, ISO 8130-5, ISO 8130-3, RoHS Fan ISO 9001, CE (89/336/EEC EMC, 73/23/EEC LVD), RoHS Glass ISO 9001, EN 12150 1: 2000 tempered and secure Fixings DIN 7985, DIN 965, DIN 7981, DIN 934, DIN 985, DIN 933, RoHS Castors TS EN 12530,TS EN 12532, RoHS Lock DIN 1743, DIN 53571, RoHS 58KEY FEATURESMain profile (framework) has an aesthetic structure which increases mechanical resistance, folded at an angle of 45 degrees and consisting of 6 bends for each profile. In total; 24 folds provide framework stability.Tested to provide (x, y, z) axis resistance that meets EN 61587-1 /5.2.1 and 5.2.2, and external impact resistance that meets EN 61587-1 / 5.3.3. Bottom and upper case have a structure to increase resistance and strength of cabinet by mono block bended, welded and profile-interlocking design.Profilesare manufactured to interlock bottom and upper case with screws.The bottom case providing cable access is fitted with a sliding blanking access plate to prevent dust. A rubber edge on the cable access plate and sliding structure, allows cables to be placed into the cabinet and fixed inside with no damage.Additionally both on top and bottom, there are brushed cable entry plates for mass cabling needs. Rear door is manufactured with 2 cable access part top/ bottom with brush. Rear door in standard configuration is a double opening door which is removable and lockable. For options please see the related diagrams and technical charts in pages 4955. Side panels have a structure that can be opened and removed with slam latch and key and are lockable and removable. Front doors are a framed glass structure which is tempered, anti-static, secure and smoked glass (4 mm thickness) with a decorative stripe, according to EN 12150-1:2000 standard. Front door in standard configuration has left and right metal frame structure with high density polyurethane adhesive and screw and double opening. For options please see the related diagrams and technical charts in pages 49-55. Front door is a double openning door which can be opened to 125 degrees, removable and lockable with handle type locking unit. Pagoda style vented top panel with a dedicated space of ventilation fan module system allows easy installation of max. 4 fans. 19(inch) mounting angles (2 ea. in front and 2 ea. in rear) are part of the cabinet interior configuration and adjustable in depth. Baying is possible for side by side applications without side panels.. Levelling feet are standard in shipping configuration. The cabinet meets EN 61587-1, IEC 60917, IEC 60297 standards, RoHS compliancy, Gost andTSE certified. Cabinets are manufactured in our factory which has ISO 9001: 2008 Quality Assurance System and our responsibility for enviroment with ISO 14001: 2004 Environmental Management System. 59. TECHNICAL SPECIFICATIONSCustom number 85380000 / 85381000 / 853710990019 Shipping structure Assembled Mounting type Stand alone Load carrying capacity (kg) 600 Certification on product TSE, Gost Surface finish Electrostatic powder coated c/with surface treatment , 80 +/ - 5 micron paint thickness and tested according to IEC60068-21,2-2, 2-30,2-42, 2-43, 2-49, 2-11 STANDARD PRODUCT Standard colour RAL 7035, RAL 9005 Standard stripe colour Orange Baying Possible with baying kit for side by side applications without side panels IP protection standard IP20 FRONT DOOR Shatterproof glass with left and right metal frame Glass 4 mm thickness full-length smoked, shatterproof, tempered, secure Front door construction Double opening door Front door lock 2 point locking barrel type Adhesive material High density polyurethane DIN 53479, DIN 53505 Hinge system Spring loaded Door opening angle and swapping 125 degree SIDE PANEL Solid metal, 1 mm left and right (2 ea.) Side panel construction Lockable, removable c/with slam latches and lock Side panel lock Barrel type lock unit, single point + Slam latch (2 ea)REAR DOOR Solid metal, 1 mm Rear door construction Double door opening,lockable, removableRear door lock Barrel type lock unit, single point Hinge system Spring loaded Door opening angle and swapping 125 degree TOP COVER Solid metal 1,2 mm Top cover construction Pagoda type, allows efficient air removal FRAMEWORKTop and bottom base units Solid metal 1,5 mm Top and bottom base units construction Completely welded corner socket system Uprights Solid metal, 1,5 mm Uprights construction Tightly fixed into top and bottom base units 6 times foldedINTERIOR PARTS19 mounting angles Solid metal, 1,5 mm 3 times folded 800x600, 800x800 / 1 time folded for 800x1000 U marking available 2 ea. at rear, 2 ea. at front Pre-configured as 19 Zinc plated, passivated, 8-12 micron. Adjustable in depth Omega type support rails in depth Solid metal, 1,5 mm 3 times folded 2 ea. at left , 2 ea. at right up to 26U 3 ea. at left , 3 ea. at right26U and higher OPTIONS For the front and rear door options, please look at pages 49-55.For CUSTOMIZED PRODUCTS rather than above options, please contact sales department.59 60. Universal Line JUMBOAccessoriesSPECIAL ACCESSORIES* FOR JUMBOTeleskopic cable trunking Designed to protect and hide cable bundles coming from the ceiling. Since the height between ceiling and cabinet is variable, it is manufactured as telescopic to fit all dimensions. Coming complete with cover which when closed gives a professional look. Vertical cable management channels (left and right) Designed to manage large patch cable bundles in front of the cabinet. It is installed through the height of the cabinet, and each U dimension, there is a hole to pass horizontal patch cables on vertical axis.A spring hinged cover in front of the vertical cable management panel integral with slam latch.The cover protect and hide all cable bundles.When it is closed, it gives a professional look. Labour costs are reduced by %20 and is a time saving system. Vertical cable management trunking Designed to carry large cable bundles through the vertical axis of the cabinet. From top to bottom, it is continuous with the height of cabinet. Bottom edge of the trunking fits into the cabinet bottom cable entry, top edge of the trunking fits into the cabinet top cable entry. It has holes for cable access for horizantal axis. It is punched in a shape to tie the cables. Since it has a sliding cover on the trunking, cable bundles are hidden and protected.When closed, it offers a chic looking finish. *See accessories for product part numbers, definitions and please contact sales department.Professional cabling solutions with JUMBO Left and right cable management panels hide and protect all networking cables as well as providing a professional looking finish.Double opening rear doors provide space saving between cabinet and wall.60 61. UNIVERSAL LINE JUMBO FEATURESPerforated, vented Pagoda-style top providing maximum protection against dustFront door with integrated locking mechanism for added security.Side panel comes with snap closures and locks providing security, whilst allowing four-way access to the equipment.Sliding access panel on the bottom for cable entry and a brush entry on the rear panel that can be positioned on the top or bottom61 62. Universal Line PCcase free standing 600x800 - 36USTANDARD DIMENSIONS: Height: 36U Width: 600 mm Depth:780 mmSTANDARDS: ISO 9001: 2008 Quality Management Systems ISO 14001: 2004 Environmental Management System 19 mounting to IEC 297-1 EN 61587-1 mechanical structures (cabinets for electronic equipments) Overall cabinet dimensions to IEC 297-2COLOUR: RAL 9005 black RAL 7035 light grey 19 FITS YOUR DECOR AND ENVIRONMENT SECURE AND STURDY EASY TO MAINTAIN AND LARGE INNER VOLUME DUST PROOF AIR CIRCULATION WITH VENTED FILTERS62PCcase is ideal for office, factory, workshop, storage, store, gas stations and laboratories etc. as server housing. It protects your servers and devices against dust, humidity, hot/cold air but most important that against unauthorized peoples. Servers, all kind of PCs, monitors, keyboards, UPSs, switches and networking products can easily be placed in it. Its agronomy provides the keyboards at hands level and monitor is at eye level. 63. 600x800 - 36UFEATURES PCccase cabinets match all features defined for Universal Line as main construction. It has 3 sections; 1st compartment: Screen section 11U space covered, (not 19, equipped with a fixed shelf which should be base for the screen unit). 2nd Compartment: Keyboard section 3U space covered (not 19, equipped with a specific sliding shelf integrated with mouse housing and platform). 3rd Compartment: Device section 19 22U usable (19, 22U rail allowing use of all standard accessories to mount all kind of devices printers, UPS, server or any LAN/WAN devices...)All compartments are lockable. Both side doors are lockable, removable, and openable. Side doors have filtered and vented air circulation trays that allow air circulation or air entry. It is possible to use together with cooling fans which also has filtered and vented tray on top that allow air circulation. Bottom section has two door options: Glass door or solid metal door.63 64. Universal Line PCcase TECHNICAL DRAWINGS600x800 - 36UExploded viewHeight: without levelling feet (mm)Height: with levelling feet (mm)Height: with casters (mm)36U 600x780 mm PCcase, metal door section at bottomHeight: vertical mounting profile (mm)PCCASE36MDepth: max mounting profile (mm)36U 600x780 mm PCcase, glass door section at bottomDepth: overall (mm)PCCASE3664Product definition (mm)Width: overall (mm)Part numberU SizeUniversal Line PCcase cabinets 19 600 x 780 mm366007805551603176617811846 65. TECHNICAL DRAWINGS FOR 600x800 - 36U395600(Min 30) 911746(Min 701) 555658200(Min 30) 13030019Bottom viewMounting profile6007801746Front view with glass door 600Front viewSide viewBack view1746600780302350Front view with metal door Top viewIso view65 66. Universal Linefree standing accessoriesFREQUENTLY USED ACCESSORIES SELECTION TABLE FOR Universal LineEstap has a wide range of accessories: Fixed shelves, heavy duty fixed shelves, sliding shelves, fans, cooling units, vertical cable managements, cable rings, organisers, trays, plinth and so on... * See the other accessories and part number definitions on pages 173-213.* Please state colour choice in your orders. M01=RAL 9005 black and M02= RAL 7035 light greyFrequently used accessories selection table Universal Line / Shelves part numbers Fixed shelvesEnclosure Sizes* PCcase600x800600x1000800x600800x800800x1000M44SBR80 M44SBR60 M44SBR80 M44SBR100 M44SBR60 M44SBR80 M44SBR100Heavy duty fixed shelves Sliding shelves600x600---M55SR720M44HRK80 M44HRK60 M44HRK80Heavy duty sliding shelves------M44HRK60 M44HRK80M55HR720M55SR720 ---M55HR720Universal Line / Fan units part numbersPCcase600x600600x800600x1000800x600800x800800x10002 Fan unit with on/off switchM44HV2FM44HV2FM44HV2FM44HV2FM44HV2FM44HV2FM44HV2F4 Fan unit with on/off switchM44HV4FM44HV4FM44HV4FM44HV4FM44HV4FM44HV4FM44HV4F2 Fan unit with thermostat unitM44HV2FT M44HV2FT M44HV2FT M44HV2FT M44HV2FT M44HV2FTM44HV2FT4 Fan unit with thermostat unitM44HV4FT M44HV4FT M44HV4FT M44HV4FT M44HV4FT M44HV4FTM44HV4FTUniversal Line / Cable management part numbers 1U cable management panel (5 rings) Vertical cable managementUniversal Line / PDU part numbersEnclosure Sizes*Enclosure Sizes* PCcase600x600600x800600x1000800x600E44ORG1U E44ORG1U E44ORG1U E44ORG1U E44ORG1U ----800x800800x1000E44ORG1UE44ORG1UM44ORGxxU M44ORGxxU M44ORGxxUEnclosure Sizes* PCcase600x600600x800600x1000800x600800x800800x10006 way PDU with 1x16A CCT breaker,1UM446ALM446ALM446ALM446ALM446ALM446ALM446AL9 way PDU with 1x16A CCTbreaker, 2UM449ALCM449ALCM449ALCM449ALCM449ALCM449ALCM449ALC800x600800x800800x1000Universal Line / Castor part numbers Castor group Fixings/ cagenut, screw, washer (1set=20 pcs.)66Enclosure Sizes* PCcase600x600600x800600x1000M22TKGR1 M22TKGR1 M22TKGR1 M22TKGR1 M22TKGR1 M22TKGR1 KFS6X15* Please check drawing pages for cabinet sizes.KFS6X15KFS6X15KFS6X15KFS6X15KFS6X15M22TKGR1 KFS6X15 67. EUROline free standingReduce%ip5e0t sh m n*cost Real flatpack design Max. 10 min** for assembly Easy to carry and transport Easy to maintenance High volume capacity for large cable bundles * Mixed quantity and mixed size ** Measured values by Estap. It can change according to size of the enclosure67 68. EUROline free standing 600x600 - 600x800 - 600x1000 - 800x600 - 800x800 - 800x1000EUROline free standing enclosures22U 26U 32U 36U42U600 x 600*42U600 x 1000*32U 36U42U800 x 800*42U800 x 1000*600 x 800*Openable, lockable, removable side panels, front and rear doors 19 MODULAR STRUCTURE READY FOR ASSEMBLY STURDY, RUGGED STEEL CONSTRUCTION REDUCETHE SHIPMENT COST FLATPACK* Please check drawing pages for cabinet sizes.68 69. 600x600 - 600x800 - 600x1000 - 800x800 - 800x1000STANDARD DIMENSIONS: Heights: 22U, 26U, 32U, 36U, 42U Width: 600 mm Depth: 645 mm and 825 mmLOAD CARRYING CAPACITY: 400 kgHeights: 42U Width: 600 mm Depth: 1005 mmRAL 7035 light greyHeights: 32U, 36U, 42U Width: 780 mm Depth: 825 mm Height: 42U Width: 780 mm Depth: 1005 mmCOLOUR: RAL 9005 blackSTANDARDS: ISO 9001: 2008 Quality Management Systems ISO 14001: 2004 Environmental Management System 19 mounting to IEC 297-1 EN 61587-1 mechanical structures (cabinets for electronic equipment) Overall cabinet dimensions for IEC 297-2KEY FEATURES High quality production Aesthetic look Sturdy, rugged steel construction Openable, lockable, removable side panels, front and rear doors. Secure, tempered front door,with left&right metal frames, and handle type lock. Easy to maintain, high volume capacity for large cable bundles. Upper case is suitable for fan units and brushed cable entry. Welded corners and sturdy construction. Bottom case is completely open for large cable entries. Bottom plate with sliding type Estap standard cable entry, can be used to close case. Rugged steel for 19 mounting angles Reduce shipment costs %50* Easy to transport Strong protection against transport damages Easy to assemble After mounting, cardboard packaging and wooden pallets may be retained and reused for future shipments. * Mixed quantity and mixed size69 70. EUROline free standing SELECTION STEPS FOR 600x600 - 600x800STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section in the catalogue, has a Main part numbers and Options sections. The below example explains how to select the right options. The product part number has the below structure: P roduct range name+U height (HHU)+Width&Depth (WD)+Rear door option (RX)The product options have the below structure: C olour option (MX)+Front door option (FX)HOW TO SELECT THE OPTIONS Step 1 Please choose product part number. For example: EU42U68 Step 2 Please choose the colour from the table and place it after the part number. For example: EU42U68 - M02 (MX=Look at the MX colour options on the next page) Step 3 Please choose the front door from the table and place it after MX colour. For example: EU42U68 - M02 - F18 (FX= Look at the FX front door options on the next page) Step 4 Please choose the rear door from the table and place it after FX front door option. For example: EU42U68 - M02 - F18 - R10 (RX= Look at the RX rear door options on the next page)70 71. PART NUMBER DEFINITION 600x600 - 600x800FXMAIN PART NUMBER STRUCTURE EU Front door option- HU - WD HProduct range EUROlineEUWidth & depthU height+HHU 22U+F18WD 66 6826UEU60032U 36U 42UEU:EUROline free standing product range HHU:U height WD:Width and depthHOPTIONS MX - FX - RX Front door optionColourMX M01+FX F18Rear door option+RXFront viewR10RXM02Rear door option 600R10MX: Colour options RAL 9005 black M01= RAL 7035 light grey M02= FX:Front door option Single opening shatter proof glass door with left F18= and right metal frame slotted, single point handled locking HRX: Rear door option Single opening solid metal rear door with R10= barrel type lock unit, single pointH= Enclosure heightBack view71 72. EUROline free standing TECHNICAL DRAWINGS FOR 600x600 - 22U/26U/32U/36U/42UR10F18*Exploded viewPart numberProduct definition (mm)U SizeWidth: overall (mm)Depth: overall (mm)Depth: max mounting profile (mm)Height: vertical mounting profile (mm)Height: without levelling feet (mm)Height: with levelling feet (mm)Height: with casters (mm)EUROline free standing cabinets 19 600 x 645 mmEU22U6622U 600x64522600645331,51070113511501215EU26U6626U 600x64526600645331,51245131013251370EU32U6632U 600x64532600645331,51515157515901655EU36U6636U 600x64536600645331,51700175517701825EU42U6642U 600x64542600645331,51960202520402105* Bottom cover plate is an optional accessory.72 73. TECHNICAL DRAWINGS FOR 600x600 - 22U/26U/32U/36U/42UF18600H(Min 93,5) 155566(Min 455) 331,5(Min 91,5) 15352119Bottom view*Note: *Bottom is empty, the top of theFront viewMounting profileenclosure appears600645566521300200HBottom view* Note: * Bottom cover plate is an optionalaccessorySide view645600 300Back view72Front viewTop view H= Enclosure heightIso view73 74. EUROline free standing TECHNICAL DRAWINGS FOR 600x800 - 22U/26U/32U/36U/42UR10F18* Exploded viewPart numberProduct definition (mm)U SizeWidth: overall (mm)Depth: overall (mm)Depth: max mounting profile (mm)Height: vertical mounting profile (mm)Height: without levelling feet (mm)Height: with levelling feet (mm)Height: with casters (mm)EUROline free standing cabinets 19 600 x 825 mmEU22U6822U 600x82522600825511,51070113511501215EU26U6826U 600x82526600825511,51245131013251395EU32U6832U 600x82532600825511,51515157515901655EU36U6836U 600x82536600825511,51700175517701840EU42U6842U 600x82542600825511,51960202520402110* The bottom cover plate is an optional accessory.74 75. TECHNICAL DRAWINGS FOR 600x800 - 22U/26U/32U/36U/42U521F18(Min 635) 511,5746(Min 91,5) 153600(Min 91,5) 153H19Bottom view*Mounting profileNote: * Bottom is empty, the top of the enclosure appears521825746200600Front view300 HBottom view* Note: * Bottom cover plate is an optionalaccessorySide viewFront viewBack view82572600 300Top view H= Enclosure heightIso view75 76. EUROline free standing SELECTION STEPS FOR 600x1000STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section in the catalogue, has a Main part numbers and Options sections. The below example explains how to select the right options. The product part number has the below structure: P roduct range name+U height (HHU)+Width&Depth (WD)+Rear door option (RX)The product options have the below structure: C olour option (MX)+Front door option (FX)HOW TO SELECT THE OPTIONS Step 1 - Please choose product part number. For example: EU42U61 Step 2 - Please choose the colour from the table and place it after the part number. For example: EU42U61 - M02 (MX=Look at the MX colour options on the next page) Step 3 - Please choose the front door from the table and place it after MX colour. For example: EU42U61 - M02 - F18 (FX= Look at the FX front door options on the next page) Step 4 - Please choose the rear door from the table and place it after FX front door option. For example: EU42U61 - M02 - F18 - R10 (RX= Look at the RX rear door options on the next page)76 77. PART NUMBER DEFINITION FOR 600x1000FXMAIN PART NUMBER STRUCTURE Front door optionsEU - HHU - WD Product range EUROlineEUWidth & depthU height+EUHHU+WD6006142UEU:EUROline free standing product range HHU:U height WD:Width and depthF21600F18*HHOPTIONS MX - FX - RX Front door optionsColour optionsMX+FXFront viewFront viewRear door options+RXM01F18*R10**M02F21R07RX RX Rear door options Rear door optionsMX:Colour options RAL 9005 black M01= RAL 7035 light grey M02= FX:Front door options Single opening shatter proof glass door with F18*= left and right metal frame slotted, single point handled locking Single opening %63 perforated front door, F21= full slotted frame, single point handled locking RX: Rear door options Single opening solid metal rear doorwith R10**= barreltype lock unit, single point locking Double opening complete framed % 63 R07= perforated front door, 3 point handled locking600R10**600HBack viewR07HBack viewH= Enclosure height H= Enclosure height * F18 is the standard front door. ** R10 is the standard rear door.77 78. EUROline free standing TECHNICAL DRAWINGS FOR 600x1000 - 42UR07R10**F21 F18*Exploded viewPart numberProduct definition (mm)U SizeWidth: overall (mm)Depth: overall (mm)Depth: max mounting profile (mm)Height: vertical mounting profile (mm)Height: without levelling feet (mm)Height: with levelling feet (mm)Height: with casters (mm)EUROline free standing cabinets 19 600 x 1005 mmEU42U6142U 600x1005426001005702,51960202520402110* F18 is the standard front door. ** R10 is the standard rear door.78 79. TECHNICAL DRAWINGS FOR 600x1000 - 42U600522(Min 85,5) 147522(Min 825,5) 702,50926463(Min 86,5) 148F18*Bottom view* Note: *Bottom is empty, the top of the enclosure appearsH19 Mounting profile600Front view1005600HF21HSide viewFront viewBack viewFront view600100572300Top viewIso viewH= Enclosure height * F18 is the standard front door.79 80. EUROline free standing SELECTION STEPS FOR 800x800 - 800x1000STEPS TO SELECT RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section on the catalogue, has a Main part numbers and Options sections. The below example explains how to select the right options. The product part number has the below structure: P roduct range name+U height (HHU)+Width&Depth (WD)+Rear door option (RX)The product options have the below structure: C olour option (MX)+Front door option (FX)HOW TO SELECT THE OPTIONS Step 1 Please choose product part number. For example: EU42U88 or EU42U81 Step 2 Please choose the colour from the table and place it after the part number. For example: EU42U88 - M02 (MX=Look at the MX colour options on the next page) or EU42U81 - M02 (MX=Look at the MX colour options on the next page) Step 3 Please choose the front door from the table and place it after MX colour. For example: EU42U88 - M02 - F20 (FX= Look at the FX front door options on the next page) or EU42U81 - M02 - F20 (FX= Look at the FX front door options on the next page) Step 4 Please choose the rear door from the table and place it after FX front door option. For example: EU42U88 - M02 - F20 - R12 (RX= Look at the RX rear door options on the next page) or EU42U81 - M02 - F20 - R12 (RX= Look at the RX rear door options on the next page)80 81. PART NUMBER DEFINITION 800x800 - 800x1000FXMAIN PART NUMBER STRUCTURE EU - HHU - WD Product range EUROlineEUWidth & depthU height+HHU 32UFront door options+780HH81EU:EUROline free standing product range HHU:U height WD:Width and depthFront viewFront viewRX OPTIONSMX - FX - Rear door optionsRX780Front door optionsColour optionsMX+FXF19*8842U 42U780WD36UEUF20**R12***Rear door options+RXM01F20**R12***M02F19*R11R08*R08*HF19*MX:Colour options RAL 9005 black M01= RAL 7035 light grey M02=Back view 780FX:Front door options Double opening shatter proof glass door with F20**= left and right metal frame slotted, 3 point handled locking Single opening %63 perforated front door, F19= full slotted frame, single point handled locking Double opening complete framed %63 R08*= perforated front door, 3 point handled lockingRX: Rear door options Double opening metal rear door with R12***= 3 point handled locking Single opening solid metal rear door with R11= barrel type lock unit, single point lock unit Double opening complete framed %63 R08*= perforated front door,3 point handled locking F19*= Single opening %63 perforated front door, full slotted frame, single point handled lockingHBack viewR08*780 HH= Enclosure height * R08 and F19 can be used as both front and rear door. ** F20 is the standard front door. *** R12 is the standard rear door.R11Back view81 82. EUROline free standing TECHNICAL DRAWINGS FOR 800x800 - 32U/36U/42UF19** R08** R11 R12****F19** F20*** R08***Exploded viewPart numberProduct definition (mm)U SizeWidth: overall (mm)Depth: overall (mm)Depth: max mounting profile (mm)Height: vertical mounting profile (mm)Height: without levelling feet (mm)Height: with levelling feet (mm)Height: with casters (mm)EUROline free standing cabinets 19 780 x 825 mmEU32U8832U 780x82532780825511,51515152515401655EU36U8836U 780x82536780825511,51630175517701840EU42U8842U 780x82542780825511,51960202520402110* The bottom cover plate is optional. ** R08 and F19 can be used as both front and door rear door. *** F20 is the standard front door. **** R12 is the standard rear door.82 83. TECHNICAL DRAWINGS FOR 800x800 - 32U/36U/42U780F20*701(Min 725) 511,5H(Min 47,5) 154776746(Min 44,5) 15151319Bottom view*Mounting profileNote: *Bottom is empty, the top of theFront viewenclosure appears780701825780F19200300746HHBottom viewNote: Bottom cover plate is an optionalaccessoryFront viewSide viewBack viewFront view780Top view H= Enclosure height747300300R0872702HIso viewFront view * F20 is the standard front door.83 84. EUROline free standing TECHNICAL DRAWINGS FOR 800x1000 - 42UF19** R08** R12**** R11F19**F20*** R08***Exploded viewPart numberProduct definition (mm)U SizeWidth: overall (mm)Depth: overall (mm)Depth: max mounting profile (mm)Height: vertical mounting profile (mm)Height: without levelling feet (mm)Height: with levelling feet (mm)Height: with casters (mm)EUROline free standing cabinets 19 780 x 1005 mmEU42U8142U 780x1005427801005704,51960202520402110* The bottom cover plate is optional. ** R08 and F19 can be used as both front and door rear door. *** F20 is the standard front door. **** R12 is the standard rear door.84 85. TECHNICAL DRAWINGS FOR 800x1000 - 42U701 513780H(Min 40) 146,5926(Min 784,5) 704,50(Min 40) 146,5F20*Bottom view* Note: *Bottom is empty, the top of the enclosure appears19Mounting profileFront view1005780780F19H HFront viewSide viewBack view780 702Front view780R0872300H300927100555H= Enclosure heightTop viewIso viewFront view * F20 is the standard front door.85 86. EUROline free standing TECHNICAL SPECIFICATIONSTESTS AND CERTIFICATIONS Environment EN61587-1/4.2, IEC60068-2-1, IEC60068-2-2, IEC60068-2-30, IEC60917 and IEC60297 Industrial environment EN61587-1/4.3, IEC60068-2-42, IEC60068-2-43 and IEC60068-2-49,IEC60068-2-1, IEC60917 and IEC60297 Statical mechanical structure load test EN61587-1 / 5.2.1, IEC60917 and IEC60297 Statical mechanical structure stability EN61587-1 / 5.2.2, IEC60917 and IEC60297 Dynamic load, vibration and mechanical stroke EN61587-1 / 5.3.1, EN61587-1 / 5.3.3, IEC60917, IEC60297, IEC62208 Grounding continuity EN61587-1 / 6.2, IEC60917 and IEC60297 Fire and Flame Resistance EN61587-1 / 6.3, IEC60917 and IEC60297 Corrosion ISO9227 and ASTM B 117-85, IEC60917 and IEC60297 IP protection degree IP00.When bottom cover plate is used, it becomes IP20 IP20 accordingly EN61587-1 / 6.4, IEC60529, IEC60917 and IEC60297 Transportation ETS300019-1-2 Class2.3 Storage ETS300019-1-1 Class1.2 Security EN60950_LVD PURCHASED PRODUCT CERTIFICATIONS Sheet steel DIN EN 10130 99 Ereli DC- 01 6112, 7122, RoHS Electrostatic powder coating ISO 9001, ISO 2178, ISO 2813, ISO 6272, ISO 8130-5, ISO 8130-3, RoHS Fan ISO 9001, CE (89/336/EEC EMC, 73/23/EEC LVD), RoHS Glass ISO 9001, EN 12150 1: 2000 tempered and secure Fixings DIN 7985, DIN 965, DIN 7981, DIN 934, DIN 985, DIN 933, RoHS Castors TS EN 12530,TS EN 12532, RoHS Lock DIN 1743, DIN 53571, RoHS86KEY FEATURES Main profile vertical (framework) has a structure which increases mechanical resistance with aesthetic appearance and a specially closed profile system of 30x30 mm from automation industry. Folded with an angle of 90 degree:The corner joints are welded with 4 fold connection brackets.The main profile vertical (framework) connects to top and bottom case with heavy duty 5 fold bended profile system.A total of 20 folds provide stability for the top and bottom case.Additionally, at 600x1000 and 800x1000 mm sizes a 5 fold (bend surface) bracket system provides additional stability, providing a 25 fold (bent surface) design criteria for the frame. Manufactured and tested to provide axial (x, y, z) resistance that meets EN 61587-1 /5.2.1 and 5.2.2, and external impact resistance that meets EN 61587-1 / 5.3.3. Using a folded profile system for structure, the bottom and upper case are connected to the vertical profile system using heavy duty screws which provide modularity. Bottom case if fully open for large cable bundles to be placed; if required to close the bottom, a cover plate can be purchased as an optional accessory with sliding type edged cable entry panel. The rubber edge on the cable access plate and sliding structure, allows cables to be placed into the cabinet and fixed inside with no damage. For W=600 mm enclosure rear door is single solid metal, removable and lockable. Integral locking is single point barrel type locking system. For W=800 mm enclosure rear door in double opening, complete metal and 3 point handled locking. For options please see the related diagrams and technical charts On pages 71-77-81.