Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

66
Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I

Transcript of Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Page 1: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Essentials of Fire Fighting, 5th Edition

Chapter 14 — Fire Streams

Firefighter I

Page 2: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–2

Chapter 14 Lesson Goal

• After completing this lesson, the student shall be able to effectively operate a solid stream nozzle, fog stream nozzle, and broken stream nozzle following the policies and procedures set forth by the authority having jurisdiction (AHJ).

Page 3: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–3

Specific Objectives

1.List methods that are used with fire streams to reduce the heat from a fire and provide protection to firefighters and exposures. 2.Discuss the extinguishing properties of water.

(Continued)

Page 4: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–4

Specific Objectives

3.Describe friction loss. 4.Define water hammer. 5.Distinguish among characteristics of fire stream sizes.

(Continued)

Page 5: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–5

Specific Objectives

6.Discuss types of streams and nozzles.7.Discuss handling handline nozzles. 8.Describe types of nozzle control valves. 9.List checks that should be included in nozzle inspections. (Continued)

Page 6: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–6

Specific Objectives

10. Operate a solid-stream nozzle. (Skill Sheet 14-I-1)11. Operate a fog-stream nozzle. (Skill Sheet 14-I-2)12. Operate a broken-stream nozzle. (Skill Sheet 14-I-3)

Page 7: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–7

Methods to Reduce Heat and Provide Protection

• Applying water or foam directly onto burning material to reduce its temperature

• Applying water or foam over an open fire to reduce the temperature so firefighters can advance handlines

• Reducing high atmospheric temperature

(Continued)

Page 8: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–8

Methods to Reduce Heat and Provide Protection

• Dispersing hot smoke and fire gases from a heated area

• Creating a water curtain to protect firefighters and property from heat

• Creating a barrier between a fuel and a fire by covering the fuel with a foam blanket

Page 9: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–9

How Water Extinguishes Fire

• Primary way is cooling• Smothering by diluting or

excluding oxygen

Page 10: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–10

Heat Absorption

• When heated to boiling point, water absorbs heat

• Visible form of steam is called condensed steam

• Components of heat absorption• Specific heat

(Continued)

Page 11: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–11

Heat Absorption

• Latent heat of vaporization

• Expansion capability• Effective

extinguishment with water generally requires steam production (Continued)

Page 12: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–12

Heat Absorption

• Water absorbs more heat when converted to steam than when heated to boiling point

Page 13: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–13

Characteristics of Water Valuable for Fire Extinguishment

• Readily available, relatively inexpensive

• Has greater heat-absorbing capacity than most other common agents

• Water changing to steam requires large amount of heat

• Can be applied in variety of ways

Page 14: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–14

Friction Loss

• That part of total pressure lost while forcing water through pipes, fittings, fire hose, and adapters

(Continued)

Page 15: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–15

Friction Loss

• When water flows through hose, couplings, appliances, its molecules rub against insides, producing friction

• Slows water flow, reduces its pressure

(Continued)

Page 16: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–16

Friction Loss

• Loss of pressure in hoseline between pumper and nozzle is most common example

• Measuring friction loss• Affected by velocity of water and

characteristics of hose layouts

(Continued)

Page 17: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–17

Friction Loss

• Generally, the smaller the hose diameter and longer the hose lay, the higher the friction loss at a given pressure, flow volume

Page 18: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–18

Factors Increasing Friction Loss

• Rough linings in fire hose• Damaged hose couplings• Kinks/sharp bends in hose• More adapters than necessary• Hoselines longer than necessary• Hose diameter too small for

volume needed

Page 19: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–19

Elevation Loss/Gain

• Elevation — Position of nozzle above or below pumping apparatus

• Elevation pressure — Gain/loss in hoseline pressure caused by gravity when there is difference in elevation

(Continued)

Page 20: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–20

Elevation Loss/Gain

• Pressure loss — When nozzle is above fire pump

• Pressure gain — When nozzle is below pump

Page 21: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–21

Water Hammer

(Continued)

Page 22: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–22

Water Hammer

• When flow of water through fire hose or pipe is suddenly stopped, shock wave produced when moving water reaches end of hose and bounces back

• Pressure surge referred to as water hammer

(Continued)

Page 23: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–23

Water Hammer

• Sudden change in direction creates excessive pressures that can cause damage to water mains, plumbing, fire hose, hydrants, fire pumps

• Can often be heard as distinct clank

• To prevent when water flowing, close components slowly

Page 24: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–24

Identifying Fire Streams

• By size and type• Size = Volume of flowing per

minute• Type = specific pattern/shape of

water• Rate of discharge measured in

gallons per minute (gpm) or liters per minute (L/min)

Page 25: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–25

Fire Stream Classifications

• Low-volume stream• Handline stream• Master stream

Page 26: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–26

Fire Stream Considerations

• Volume discharged determined by design of nozzle, pressure at nozzle

• To be effective, stream must deliver volume of water sufficient to absorb heat faster than it is being generated

(Continued)

Page 27: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–27

Fire Stream Considerations

• Type of fire stream indicates specific pattern/shape of water stream

• Requirements of effective streams

• Requirements of all streams

Page 28: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–28

Solid Stream

• Produced from fixed orifice, solid-bore nozzle

• Has ability to reach areas others might not; reach affected by several factors

• Design capabilities(Continued)

Page 29: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–29

Solid Stream

• Velocity of stream a result of nozzle pressure

• Nozzle pressure, size of discharge opening determine flow

• Characteristics of effective fire streams

• Flow rate

Page 30: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–30

Advantages of Solid Streams

• May maintain better interior visibility than others

• May have greater reach than others

• Operate at reduced nozzle pressures per gallon (liter) than others

• May be easier to maneuver (Continued)

Page 31: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–31

Advantages of Solid Streams

• Have greater penetration power• Less likely to disturb normal

thermal layering of heat, gases during interior structural attacks

• Less prone to clogging with debris

(Continued)

Page 32: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–32

Advantages of Solid Streams

• Produce less steam conversion than fog nozzles

• Can be used to apply compressed-air foam

Page 33: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–33

Disadvantages of Solid Streams

• Do not allow for different stream pattern selections

• Provide less heat absorption per gallon (liter) delivered than others

• Hoselines more easily kinked at corners, obstructions

Page 34: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–34

Fog Stream

• Fine spray composed of tiny water droplets

• Design of most fog nozzles permits adjustment of tip to produce different stream patterns

(Continued)

Page 35: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–35

Fog Stream

• Water droplets formed to expose maximum water surface for heat absorption

• Desired performance of fog stream nozzles judged by amount of heat that fog stream absorbs and rate by which the water is converted into steam/vapor (Continued)

Page 36: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–36

Fog Stream

• Nozzles permit settings of straight stream, narrow-angle fog, and wide-angle fog

• Nozzles should be operated at designed nozzle pressure

(Continued)

Page 37: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–37

Fog Stream

• Several factors affect reach of fog stream

• Interaction of these factors on fog stream results in fire stream with less reach than that of straight or solid stream

(Continued)

Page 38: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–38

Fog Stream

• Shorter reach makes fog streams less useful for outside, defensive fire fighting operations

• Well suited for fighting interior fires

Page 39: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–39

Fog Stream: Waterflow Adjustment

• Two types of nozzles control rate of water flow through fog nozzle

• Manually adjustable nozzles• Automatic nozzles

Page 40: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–40

Fog Stream: Nozzle Pressure

• Combination nozzles designed to operate at different pressures

• Designated operating pressure for most combination nozzles is 100 psi (700 kPa)

(Continued)

Page 41: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–41

Fog Stream: Nozzle Pressure

• Nozzles with other designated operating pressures available

• Setbacks of nozzles with lower operating pressures

Page 42: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–42

Advantages of Fog Streams

• Discharge pattern can be adjusted for situation

• Can aid ventilation• Reduce heat by exposing

maximum water surface for heat absorption

• Wide fog pattern provides protection to firefighters

Page 43: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–43

Disadvantages of Fog Streams

• Do not have as much reach/penetrating power as solid streams

• More affected by wind than solid streams

• May disturb thermal layering • May push air into fire area,

intensifying the fire

Page 44: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–44

Broken Stream

• One that has been broken into coarsely divided drops

• While solid stream may become broken stream past point of breakover, true broken stream takes on that form as it leaves nozzle

• Cellar nozzle is an example

Page 45: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–45

Advantages of Broken Streams

• Absorb more heat per gallon (liter) than solid stream

• Have greater reach, penetration than fog stream

• Can be effective on fires in confined spaces

Page 46: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–46

Disadvantages of Broken Streams

• May have sufficient continuity to conduct electricity

• Stream may not reach some fires

Page 47: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–47

Handline Nozzles

• Differing designs cause each one to handle somewhat differently when operated at recommended pressure

• Those with variable patterns may handle differently in different settings

(Continued)

Page 48: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–48

Handline Nozzles

• The water pattern produced by nozzle may affect ease of operation

• Nozzles not always easy to control at/above standard operating pressures

Page 49: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–49

Solid-Stream Nozzles

• When water flows from nozzle, reaction equally strong in opposite direction, thus a force pushes back on person handling hoseline

(Continued)

Page 50: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–50

Solid-Stream Nozzles

• Reaction caused by velocity, flow rate, discharge pattern of stream

• Reaction can make nozzle difficult to handle

• Increasing nozzle discharge pressure, flow rate increases nozzle reaction

Page 51: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–51

Fog Stream Nozzles

• When water is discharged at angles from center line of nozzle, reaction forces may counterbalance each other, reduce nozzle reaction

• Balancing of forces is why a nozzle set on wide-angle fog handles more easily than straight-stream pattern

Page 52: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–52

• Enable operator to start, stop, or reduce flow of water while maintaining effective control of nozzle

• Allow nozzles to open slowly so operator can adjust as nozzle reaction increases

Nozzle Control Valves

(Continued)

Page 53: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–53

Nozzle Control Valves

• Also allow nozzles to be closed slowly to prevent water hammer

• Three main types

Page 54: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–54

Ball Valve

• Most common• Provides effective

control during nozzle operation with minimum effort

(Continued)

Page 55: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–55

Ball Valve

• Ball, perforated by smooth waterway, is suspended from both sides of nozzle body and seals against seat

• Ball can be rotated up to 90 degrees by moving valve handle backward to open and forward to close (Continued)

Page 56: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–56

Ball Valve

• Nozzle will operate in any position between fully closed, fully open

• Operating nozzle with valve in fully open position gives maximum flow, performance

Page 57: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–57

Slide Valve

• Cylindrical slide valve control seats movable cylinder against shaped cone to turn off flow of water

(Continued)

Page 58: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–58

Slide Valve

• Flow increases/decreases as shutoff handle is moved to change position of sliding cylinder relative to cone

• Stainless steel slide valve controls flow of water through nozzle without creating turbulence

(Continued)

Page 59: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–59

Slide Valve

• Pressure control compensates for increase/decrease in flow by moving baffle to develop proper tip size, pressure

Page 60: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–60

Rotary Control Valve

• Found only on rotary fog nozzles• Consists of exterior barrel guided by

screw that moves it forward/backward, rotating around interior barrel

• Major difference between rotary control and other valves is they also control discharge pattern of stream

Page 61: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–61

Nozzle Inspections

• Swivel gasket for damage or wear; replace worn or missing gaskets

• External damage to the nozzle• Internal damage and debris • Ease of operation of the nozzle

parts • Pistol grip (if applicable) is secured

to the nozzle

Page 62: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–62

Summary

• To fight fires safely and effectively, firefighters must know the capabilities and limitations of all the various nozzles and extinguishing agents available in their departments.

(Continued)

Page 63: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–63

Summary

• They must understand the effects that wind, gravity, velocity, and friction have on a fire stream once it leaves the nozzle.

(Continued)

Page 64: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–64

Summary

• Firefighters must know what operating pressure their nozzles require and how the nozzles can be adjusted during operation.

Page 65: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–65

Review Questions

1.What are the ways that water can extinguish fire?2.Define friction loss, elevation loss/gain, and water hammer.3.What factors can increase friction loss in fire hose?

(Continued)

Page 66: Essentials of Fire Fighting, 5 th Edition Chapter 14 — Fire Streams Firefighter I.

Firefighter I14–66

Review Questions

4. What are the three size classifications of fire streams? 5.What is the difference between a solid stream and a fog stream?