Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

120
Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I

Transcript of Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Page 1: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Essentials of Fire Fighting, 5th Edition

Chapter 13 — Fire Hose

Firefighter I

Page 2: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–2

Chapter 13 Lesson Goal

• After completing this lesson, the student shall be able to use, care for, and perform maintenance on fire hose, couplings, hose appliances, and tools and perform various hose loads and finishes according to the authority having jurisdiction (AHJ).

Page 3: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–3

Specific Objectives

1.Discuss fire hose sizes. 2.Describe types of fire hose damage and practices to prevent such damage. 3.Discuss general care and maintenance of fire hose.

(Continued)

Page 4: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–4

Specific Objectives

4.Distinguish between characteristics of threaded couplings and nonthreaded couplings. 5.Discuss care of fire hose couplings. 6.Describe the characteristics of hose appliances and tools. (Continued)

Page 5: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–5

Specific Objectives

7.Describe common hose rolls. 8.List general hose loading guidelines. 9.Describe common hose loads. 10. Describe hose load finishes. 11. Discuss preconnected hose loads for attack lines.

(Continued)

Page 6: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–6

Specific Objectives

12. List guidelines when laying hose. 13. Describe the basic hose lays for supply hose. 14. Describe procedures for handling preconnected and other hose.

(Continued)

Page 7: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–7

Specific Objectives

15. List general safety guidelines that should be followed when advancing a hoseline into a burning structure. 16. Discuss procedures for advancing hose. 17. Describe techniques for operating hoselines. (Continued)

Page 8: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–8

Specific Objectives

18. Inspect and maintain hose. (Skill Sheet 13-I-1)19. Make a straight hose roll. (Skill Sheet 13-I-2)20. Make a donut hose roll. (Skill Sheet 13-I-3)

(Continued)

Page 9: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–9

Specific Objectives

21. Couple a hose. (Skill Sheet 13-I-4) 22. Uncouple a hose. (Skill Sheet 13-I-5)23. Make the accordion hose load. (Skill Sheet 13-I-6)24. Make the horseshoe hose load. (Skill Sheet 13-I-7) (Continued)

Page 10: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–10

Specific Objectives

25. Make the flat hose load. (Skill Sheet 13-I-8)26. Make the preconnected flat hose load. (Skill Sheet 13-I-9)27. Make the triple layer hose load. (Skill Sheet 13-I-10)

(Continued)

Page 11: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–11

Specific Objectives

28.Make the minuteman hose load. (Skill Sheet 13-I-11)

29.Connect to a hydrant using a forward lay. (Skill Sheet 13-I-12)

30.Make the reverse hose lay. (Skill Sheet 13-I-13)

(Continued)

Page 12: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–12

Specific Objectives

(Continued)

31. Advance the preconnected flat hose load. (Skill Sheet 13-I-14)32. Advance the minuteman hose load. (Skill Sheet 13-I-15)33. Advance the triple layer hose load. (Skill Sheet 13-I-16)

Page 13: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–13

Specific Objectives

(Continued)

34. Advance hose — Shoulder-load method. (Skill Sheet 13-I-17)35. Advance hose — Working line drag method. (Skill Sheet 13-I-18)36. Advance a line into a structure. (Skill Sheet 13-I-19)

Page 14: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–14

Specific Objectives

37. Advance a line up and down an interior stairway. (Skill Sheet 13-I-20)38. Advance an uncharged line up a ladder into a window. (Skill Sheet 13-I-21)

(Continued)

Page 15: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–15

Specific Objectives

(Continued)

39. Advance a charged line up a ladder into a window. (Skill Sheet 13-I-22)

40.Extend a hoseline. (Skill Sheet 13-I-23)41. Simulate the procedure for controlling a loose hoseline. (Skill Sheet 13-I-24)

Page 16: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–16

Specific Objectives

42. Replace a burst hoseline. (Skill Sheet 13-I-25)43. Operate a charged attack line from a ladder. (Skill Sheet 13-I-26)

Page 17: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–17

Fire Hose

• Produced in different diameters, each for specific purposes

• Size refers to outside diameter• Most commonly cut, coupled into

pieces of 50 or 100 feet (15 or 30 m)

(Continued)

Page 18: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–18

Fire Hose

Page 19: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–19

Intake Hose

• Used to connect fire department pumper or portable pump to water source

• Two groups– Soft intake hose– Hard intake hose

Page 20: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–20

NFPA® Standards

• NFPA® 1961, Standard on Fire Hose, lists specifications for fire hose

• NFPA® 1963, Standard for Fire Hose Connections, lists specifications for fire hose couplings and screw threads

(Continued)

Page 21: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–21

NFPA® Standards

• NFPA® 1901, Standard for Automotive Fire Apparatus, requires pumpers to carry varying sizes/amounts of hose

Page 22: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–22

Fire Hose Damage — Mechanical

• Slices, rips, abrasions on coverings

• Crushed/damaged couplings

• Cracked inner linings• Certain practices prevent damage

Page 23: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–23

Fire Hose Damage — Thermal

• Excessive heat/direct flame contact can char, melt, weaken outer jacket and dehydrate rubber lining

• Inner linings can be dehydrated when hose hangs to dry too long

• Certain practices prevent damage

Page 24: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–24

Fire Hose Damage — Organic

• Rubber-jacket hose not subject to damage caused by living organism, but this is a problem on hose with woven jacket of natural fiber if stored wet

• Mildew, mold rot fibers of hose jacket, causing hose to rupture under pressure (Continued)

Page 25: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–25

Fire Hose Damage — Organic

• If outer jacket made of synthetic fibers, will resist organic damage

• Outer jacket of some natural-fiber hose has been chemically treated to resist mildew, mold; not always 100 percent effective

• Certain practices prevent damage

Page 26: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–26

Fire Hose Damage — Chemical

• Chemicals, chemical vapors can damage outer jacket on hose or cause rubber lining to separate from inner jacket

• When hose exposed to petroleum products, paints, acids, alkalis, may be weakened

(Continued)

Page 27: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–27

Fire Hose Damage — Chemical

• Runoff water from fire may carry foreign materials that can damage hose

• Certain practices prevent damage

Page 28: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–28

Washing Hose

• Method depends on type of hose– Hard rubber booster hose, hard intake

hose, rubber-jacket collapsible hose– Woven-jacket fire hose

(Continued)

Page 29: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–29

Washing Hose

• When jacket exposed to oil– Wash with mild soap/detergent using

common scrub brush– Make sure oil completely removed– Thoroughly rinse with clear water

(Continued)

Page 30: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–30

Washing Hose

• Hose washing machines– Can make care, maintenance easier– Wash almost any size fire hose up to

3 inches (77 mm)– Flow of water into device can be

adjusted as desired

(Continued)

Page 31: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–31

Washing Hose

• Hose washing machines– Movement of water assists in

propelling hose through device– Hoseline that supplies washer with

water can be connected to pumper or used directly from hydrant

– Higher water pressure = Better results

– Cabinet-type machine

Page 32: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–32

Drying Hose

• Woven-jacket must be thoroughly dried before being reloaded on apparatus

• Methods depend on type of hose• Should be in accordance with SOP,

manufacturer’s recommendations• Some may be placed on apparatus

wet with no ill effects

Page 33: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–33

Storing Hose

• After hose has been brushed, washed, dried, should be rolled and stored in suitable racks unless it is to be placed back on apparatus

(Continued)

Page 34: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–34

Storing Hose

• Hose racks– Located in clean, well-ventilated room

or close to apparatus– Can be freestanding on floor or

mounted permanently on wall– If mobile, can be used to store and

move hose

Page 35: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–35

Threaded Fire Hose Couplings

• Consist of two major components– Male — External threads– Female — Internal threads (Continued)

Page 36: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–36

Threaded Fire Hose Couplings

• Disadvantage — One male, one female necessary to make connection unless double-male or double-female adapter used

(Continued)

Page 37: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–37

Threaded Fire Hose Couplings

• Intake hose– Sometimes equipped with two-piece

female hose couplings on each end– Threaded hose couplings on large

intake hose equipped with extended lugs providing handles for attaching to hydrant outlet/pump intake

(Continued)

Page 38: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–38

Threaded Fire Hose Couplings

• Shank– Portion of coupling that serves as

point of attachment to hose

• Lugs– Aid in tightening, loosening couplings– Aid in grasping coupling when

making, breaking coupling connections

– Types(Continued)

Page 39: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–39

Threaded Fire Hose Couplings

• Higbee cut– Special type of thread design– Tends to eliminate cross-threading– One rocker lug on each half of

coupling has small indentation to mark where Higbee cut begins

Page 40: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–40

Storz Couplings

• Referred to as sexless couplings• No distinct male/female

components• Identical to, may be connected to

other Storz couplings of same size• Designed to be

connected/disconnected with quarter turn (Continued)

Page 41: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–41

Storz Couplings

• Have lugs, slots built into swivel rings of each coupling for locking

• Must have locking devices if attached to large-diameter hose

Page 42: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–42

Rules for Care of Fire Hose Couplings

• Avoid dropping/dragging• Do not permit vehicles to run over

hose• Inspect couplings when hose

washed/dried

• Remove gasket, twist swivel in warm, soapy water (Continued)

Page 43: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–43

Rules for Care of Fire Hose Couplings

• Clean threads to remove tar, dirt, gravel, oil

• Inspect gasket, replace if cracked/creased

Page 44: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–44

Cleaning Fire Hose Couplings

• Hose-washing machines will not clean sufficiently

• Swivel part should be submerged in warm, soapy water and worked forward and backward

(Continued)

Page 45: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–45

Cleaning Fire Hose Couplings

• Male threads should be cleaned with stiff brush

• Wire brush may be necessary• Swivel gasket• Expansion-ring gasket

Page 46: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–46

Hose Appliances

• Any piece of hardware used with fire hose to deliver water

(Continued)

Page 47: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–47

Hose Appliances

• Valves– Control flow of water in hoselines, at

hydrants, at pumpers– Ball valves– Gate valves– Butterfly valves– Clapper valves

(Continued)

Page 48: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–48

Hose Appliances

• Valve devices– Allow number of hoselines operating

on fire ground to be increased/decreased

– Wye appliances– Siamese appliances– Water thief appliances– Large-diameter hose appliances– Hydrant valves

(Continued)

Page 49: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–49

Hose Appliances

• Fittings– Connect hose of different diameters,

thread types– Adapter– Reducers– Elbows– Hose caps– Hose plugs (Continued)

Page 50: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–50

Hose Appliances

• Intake strainers– Devices attached

to drafting end of hard intake to keep debris from entering fire pump

– Guidelines for use

Page 51: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–51

Hose Tools

• Hose roller– Prevents damage to hose that can

occur when dragged over sharp corners

– Consists of metal frame with two or more rollers

– Can be used for protecting rope from similar edges

(Continued)

Page 52: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–52

Hose Tools

• Hose jacket– Can be installed on ruptured section of

hoseline to temporarily close rupture– Consists of hinged two-piece metal

cylinder– Made in two sizes– Encloses hose so can operate at full

power– Can be used to connect hose with

mismatched couplings(Continued)

Page 53: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–53

Hose Tools

• Hose clamp– Can be used to stop flow of water in

hoseline– Three types — Screw-down, press-

down, hydraulic press– Can injure firefighters/damage hose if

applied incorrectly – Several general rules for use

(Continued)

Page 54: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–54

Hose Tools

• Spanner– Used to tighten/loosen couplings– May have other built-in features

(Continued)

Page 55: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–55

Hose Tools

• Hydrant wrench– Used to remove caps from hydrant

outlets, open hydrant valves– Equipped with pentagonal opening

fitting most standard hydrant operating nuts

– May be equipped with spanner

(Continued)

Page 56: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–56

Hose Tools

• Rubber mallet — Strike lugs to tighten/loosen couplings

• Hose bridge/ramp– Helps prevent damage to hose– Should be used where hose laid

across street– Can be positioned over small spills– Can be used as chafing blocks (Continued)

Page 57: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–57

Hose Tools

• Chafing blocks– Used to protect fire hose where

subjected to rubbing from vibrations– Useful where intake hose comes in

contact with pavement– May be wood, leather, old truck tires(Continued)

Page 58: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–58

Hose Tools

• Hose strap, hose rope, hose chain– Used to carry, pull fire

hose– Provide more secure

means to handle pressurized hose when applying water

Page 59: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–59

Straight Roll

• Simplest• Starts at one end,

usually male coupling; to complete roll hose toward other end

• When complete, female end exposed and male protected in center of roll (Continued)

Page 60: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–60

• Used in situations– When loaded back on apparatus at fire– When returned to quarters for washing– When placed in storage

• Easy loading of minuteman load• Methods to indicate need for

repair/test

Straight Roll

Page 61: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–61

Donut Roll

• Used in situations where hose is likely to be deployed for use directly from roll

(Continued)

Page 62: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–62

Donut Roll

• Advantages over straight roll– Better control– Hose rolls out easier– Facilitates connecting to other

couplings

• Can be performed by 1-2 firefighters

Page 63: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–63

Twin Donut Roll

• Works well on 1½-inch (38 mm) and 1¾-inch (45 mm) hose

• Creates compact roll that is easily transported, carried

• If couplings offset about 1 foot (0.3 m), can be coupled together after roll tied

Page 64: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–64

Self-Locking Twin Donut Roll

• Twin donut roll with built-in carrying loop formed from hose itself

• Loop locks over couplings to keep intact

• Length of carrying loop may be adjusted

Page 65: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–65

Hose Beds

• Hose compartments on fire apparatus

• Vary in size, shape• Sometimes built for specific needs• Front of hose bed• Rear of hose bed• Split beds

Page 66: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–66

Hose Loading Guidelines

• Check gaskets, swivel before connecting couplings

• Keep flat sides of hose in same plane when two sections connected

• Tighten couplings hand-tight• Remove kinks, twists when bent to

form loop in hose bed (Continued)

Page 67: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–67

Hose Loading Guidelines

• Make short fold/reverse bend in hose during loading so couplings not too close to front or rear of hose bed and will not flip over when pulled out of bed

• Load large-diameter hose with all couplings near front of bed

• Do not pack too tightly

Page 68: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–68

Accordion Load

• Derives name from manner in which it appears after loading

• Procedure• Advantages

Page 69: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–69

Horseshoe Load

• Named for way it appears after loading

• Procedure• Advantage• Disadvantages

(Continued)

Page 70: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–70

Horseshoe Load

• In single hose load, may be started on either side

• Steps for split hose bed

Page 71: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–71

Flat Load

• Easiest to load• Suitable for any size supply hose• Best way for large-diameter hose• Advantage• Disadvantage

(Continued)

Page 72: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–72

Flat Load

• May be started on either side of single hose bed

• In split hose bed, lay first length against partition with coupling hanging appropriate distance below hose bed

• Large-diameter hose

Page 73: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–73

Finishes for Forward Lays

• Designed to facilitate making hydrant connection

• Not as elaborate as finishes for reverse lays

(Continued)

Page 74: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–74

Finishes for Forward Lays

• Straight finish– Last length or two of hose flaked

loosely back and forth across top of hose load

– Associated with forward-lay operation– Hydrant wrench, gate valve, adapters

strapped to hose near female coupling

Page 75: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–75

Finishes for Reverse Lays

• Reverse horseshoe finish– Similar to horseshoe load– One or two 100-foot (30 m) lengths of

hose– Can be used with any size attack hose– Can be used for preconnected line– Can be loaded in two or three layers– Can be pulled from bed for arm carry(Continued)

Page 76: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–76

Finishes for Reverse Lays

• Skid load finish– Folding last three lengths of hose into

compact bundle on top of rest of load– Begins by forming 3+ pull loops

extending beyond end of hose load– Rest of hose accordion-folded across

hose used to form pull loops

Page 77: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–77

Preconnected Hose Loads for Attack Lines

• Primary lines used for fire attack by most departments

• Connected to discharge valve, placed in area other than main hose bed

• Range from 50-250 feet (15-75 m)• Can be carried in several places

Page 78: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–78

Preconnected Flat Load

• Adaptable for varying widths of hose beds

• Often used in transverse beds

• Similar to flat load for large supply hose except– Preconnected– Loops provided to aid in pulling from bed

Page 79: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–79

Triple Layer Load

• Begins with hose folded in three layers

• Designed to be pulled by one person

• Disadvantage• Can be used for all sizes attack

lines• Often preferred for larger lines

Page 80: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–80

Minuteman Load

• Designed to be pulled, advanced by one

• Advantage• Pays off shoulder as

firefighter advances toward fire• Well suited for narrow hose bed• Disadvantages

Page 81: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–81

Booster Hose Reels

• Used for booster lines• May be mounted in any of several

places on apparatus• May be hand- or power-operated• Should be loaded one layer at a

time in an even manner

Page 82: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–82

Guidelines When Laying Hose

• Do not ride in standing position to lay hose when apparatus moving

• Drive apparatus at speed no greater than one that allows couplings to clear tailboard as hose leaves bed

• Lay hose to one side of roadway

Page 83: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–83

Forward Lay

• Hose laid from water source to fire• Used when source is a hydrant and

pumper must be positioned near fire

• Hose beds should be loaded so first coupling off is female

• Operation(Continued)

Page 84: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–84

Forward Lay

• Advantages• Disadvantages• Information for firefighter at

hydrant• Making hydrant connection• Using four-way hydrant valves

Page 85: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–85

Reverse Lay

• Hose laid from fire to water source• Used when pumper must first go to

fire location so size-up can be made before laying supply line

• Most expedient way to lay hose if apparatus must stay close to water

(Continued)

Page 86: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–86

Reverse Lay

• Hose beds should be loaded so first coupling off hose bed is male

• Has become standard method for setting up relay pumping operation when using 2½-inch or 3-inch (65 or 77 mm) hose as supply line

(Continued)

Page 87: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–87

Reverse Lay

• Long lays of large hose may require pumper at hydrant to increase pressure in supply hose

• Most direct way to supplement pressure, set up drafting operations

• Disadvantages(Continued)

Page 88: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–88

Reverse Lay

• Procedures if operation involves two pumpers

• Does not require four-way hydrant valve

• Also used when pumper arrives at fire and must work alone for extended time

(Continued)

Page 89: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–89

Reverse Lay

• Making hydrant connections with soft intake hose

• Making hydrant connections with hard intake hose

Page 90: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–90

Split Lay

• Any of a number of ways to lay multiple supply hoses with a single engine

• Various types• If equipped with sexless couplings,

direction of lay is unimportant• May other options when hose bed

is divided

Page 91: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–91

Pulling Preconnected Hoselines

• Preconnected flat load • Minuteman load• Triple layer load

Page 92: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–92

Other (Not Preconnected) Hoselines

• Usually 2½-inches (65 mm) or larger

• Wyed lines• Shoulder loads from flat/horseshoe

loads• Shoulder loads from accordion or

flat loads

Page 93: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–93

Working Line Drag

• One of quickest, easiest ways to move fire hose at ground level

• Use limited by available personnel

Page 94: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–94

Advancing Hoselines

• Difficult when deploying up or down stairways, from standpipes, up ladders, deep into buildings

• Easier when uncharged

Page 95: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–95

Guidelines When Advancing Hoseline into Burning Structure

• Bleed air from charged hoselines before entering

• Position nozzle operator, all members of hose team on same side of hoseline

• Check doors for heat before opening

(Continued)

Page 96: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–96

Guidelines When Advancing Hoseline into Burning Structure

• Stay low, avoid blocking ventilation openings

• Chock self-closing doors open• Check for, remove kinks from line

Page 97: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–97

Advancing Hose Up Stairway

• Should be advanced up stairways uncharged when conditions allow

• Lay uncharged hose against outside wall to keep stairs clear as possible, avoid sharp bends and kinks in hose

• If possible, position firefighter at every turn/point of resistance

Page 98: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–98

Advancing Hose Down Stairway

• Advancing uncharged hoseline easier than charged

• Advancing uncharged line recommended only when no fire, very minor fire

(Continued)

Page 99: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–99

Advancing Hose Down Stairway

• Excess hose should be flaked outside stairwall

• Firefighters must be positioned at corners, pinch points

Page 100: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–100

Advancing Hose From Standpipe

• Getting hose to upper floors of high-rise buildings can be challenging

• One solution is to have hose rolls or packs on apparatus ready to carry aloft and then connect to standpipe system

(Continued)

Page 101: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–101

Advancing Hose From Standpipe

• Hose must be brought to fire floor over aerial ladder or by interior stairway

• Crews normally stop one floor below fire floor and connect to standpipe

• If standpipe in enclosed stairwell, it is acceptable to hook up on fire floor

(Continued)

Page 102: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–102

Advancing Hose From Standpipe

• Steps once at standpipe connection

• Be alert for pressure-relief devices and follow SOPs for removal/connection

• If using certain sizes of hose, place gated wye on standpipe outlet

(Continued)

Page 103: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–103

Advancing Hose From Standpipe

• 2½-inch (65 mm) attack line may be used depending on size, nature of fire

• Extra hose should be flaked up stairs toward floor above fire

• During pickup operations, carefully drain water to prevent unnecessary damage

Page 104: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–104

Advancing Hose Up Ladder

• Easier and safer with uncharged line

• Advancing charged line• Operating hoseline from ladder

Page 105: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–105

Controlling Loose Hoseline

• Very dangerous because it may flail about or whip back and forth

• Firefighters, bystanders may be seriously injured or killed

• Methods for controlling

Page 106: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–106

Replacing Burst Sections

• Hose clamp or kink can be used to stop flow of water when replacing burst section of hose

• Two additional sections of hose should be used to replace any one bad section

Page 107: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–107

Operating Small Handlines — One Firefighter Method

• Only used during overhaul after fire or for very small outdoor nuisance fires

• Requires hoseline to be straight at least 10 feet (3 m) behind nozzle

• Firefighter should hold nozzle with one hand and hose with the other

Page 108: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–108

Operating Small Handlines — Two Firefighter Method

• Usually needed when nozzle must be advanced

• Nozzle operator duties• Backup firefighter duties

Page 109: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–109

Operating Large Handlines — One Firefighter Method

• NOT recommended when nozzle is connected to large handline

• May be used during exposure protection/overhaul operations if master stream device unavailable

(Continued)

Page 110: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–110

Operating Large Handlines — One Firefighter Method

• Large loop formed that crosses over line behind nozzle

• Firefighter sits on intersection where hose crosses and directs stream

(Continued)

Page 111: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–111

Operating Large Handlines — One Firefighter Method

• To reduce fatigue, nozzle operator can use hose strap or utility strap looped over shoulder or reduce nozzle flow if conditions allow

• Does not permit much maneuvering

Page 112: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–112

Operating Large Handlines — Two Firefighter Method #1

• Uses means of anchoring hose because of nozzle reaction

• Nozzle operator duties• Backup firefighter duties

Page 113: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–113

Operating Large Handlines — Two Firefighter Method #2

• Uses hose rope tools or utility straps to assist in anchoring hose

• Nozzle operator duties• Backup firefighter duties

Page 114: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–114

Operating Large Handlines — Three Firefighter Method

• In all cases, positioning of nozzle operator same as for two-firefighter method

(Continued)

Page 115: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–115

Operating Large Handlines — Three Firefighter Method

• Some departments prefer first backup firefighter to stand behind nozzle operator with third firefighter kneeling on hose behind second firefighter

• Another method is for all firefighters to use hose straps and remain standing

Page 116: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–116

Summary

• To fight fires safely and effectively, firefighters must know the capabilities and limitations of the various types of fire hose used in their departments.

(Continued)

Page 117: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–117

Summary

• Firefighters must know the differences between supply hose and attack hose and how to use each one.

• Firefighters must know how to load hose onto apparatus and how to make the various hose load finishes used in their department.

Page 118: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–118

Review Questions

1.List three methods to prevent each of the following types of fire hose damage: mechanical damage, thermal damage, organic damage, and chemical damage.

(Continued)

Page 119: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–119

Review Questions

2. What is the difference between threaded couplings and nonthreaded couplings? 3.List common hose rolls.

(Continued)

Page 120: Essentials of Fire Fighting, 5 th Edition Chapter 13 — Fire Hose Firefighter I.

Firefighter I13–120

Review Questions

4.List four general loading guidelines. 5. What are general safety guidelines when advancing hose into a burning structure?