ERT Timing
description
Transcript of ERT Timing
Feb 20, 2004 K.Okada 1
ERT TimingIn the DMUX file
08 12 00 00 00 00 00 3003 03 01 02 00 00 00 01B4 8C28 50 00 40 0028 50 00 40 0028 50 00 40 0028 50 00 40 0028 50 00 00 0C28 58 00 00 0C
“cable delays”.
“Level-1 latency”
Feb 20, 2004 K.Okada 2
tEMCal,RICHsignals
ERT clockCable to cable
GL1Level-1 Latency (ROC by ROC)
cable delays
MiscWrite serial string ( ROC by ROC)GTM (Whole arm)
Global timing tune
RBIB input
Vince’s lecture
Feb 20, 2004 K.Okada 3
Timing AdjustmentThe procedure might be the following.
1. Confirm the EMCal, RICH signals are in the middle of ERT clock. Using RBIB input signals in scope, see the both edge by changing the timing. (You can use any of GTM, MiscWrite, cable delay) 2. Then the next step is Level-1 latency adjustment. Check the data taken with different setting.
Feb 20, 2004 K.Okada 4
Example in Run4The next slides show the result of time scan performed on January 19, 2004. I just changed “Level-1 delay”.
Run delay data-entry GL1-entry109704 +30 yes yes109702 +20 yes yes109701 +10 yes yes109714 -10 yes yes109715 -20 marginal yes109716 -30 no yes
Feb 20, 2004 K.Okada 5
So the current timing diagram must be like this
10ns~20ns
Level-1 Latency
RBIB input
Am I correct?
Feb 20, 2004 K.Okada 6
ERT Time Scan (Jan 19)In the DMUX file
08 12 00 00 00 00 00 3003 03 01 02 00 00 00 01B4 8C28 50 00 40 0028 50 00 40 0028 50 00 40 0028 50 00 40 0028 50 00 00 0C28 58 00 00 0C
Several runs with different “cable delays”.
“Level-1 latency” wasn’t changed.
See the ERT2x2 entries.
Feb 20, 2004 K.Okada 7
Runs east westDefault : 28 50 : 00 50+10ns : 50 50 : 28 50 : 109701+20ns : 78 50 : 50 50 : 109702, 109703+30ns : A0 50 : 78 50 : 109704-10ns(1) : C8 C0 : A0 C0 : 109705-20ns(1) : A0 C0 : 78 C0 : 109712-30ns(1) : 78 C0 : 50 C0 : 109713-10ns(2) : C8 D0 : A0 D0 : 109714-20ns(2) : A0 D0 : 78 D0 : 109715-30ns(2) : 78 D0 : 50 D0 : 109716
To set minus value, I used anti-polarity. Since I was not sure thatwhich way the polarity twitch moves, I tried two ways.(1) Subtract 1 clock ticks. –10=+53-106 + 40.(2) Without any clock tick movement. –10=-53+40. From the continuity, (2) seems to be the right answer.
Feb 20, 2004 K.Okada 8
Feb 20, 2004 K.Okada 9
Feb 20, 2004 K.Okada 10
Feb 20, 2004 K.Okada 11
Feb 20, 2004 K.Okada 12
Feb 20, 2004 K.Okada 13
Feb 20, 2004 K.Okada 14
Feb 20, 2004 K.Okada 15
Feb 20, 2004 K.Okada 16
Feb 20, 2004 K.Okada 17