Erik Lundén SINAMICS G120 Akquisitionsfoliensatz V3 ppt … · SINAMICS G120 addresses new markets...
Transcript of Erik Lundén SINAMICS G120 Akquisitionsfoliensatz V3 ppt … · SINAMICS G120 addresses new markets...
Automation and Drives
A&D Drive Technology
SINAMICSDriving to the futureG120
Automation and Drives
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
SINAMICS G120
System/ProduktA&D Drive technology
24.4.2006, Page 2© Siemens AG 2006 - Subject to change without notice
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
Service
SINAMICS –The right drive for every application
SIEMENSDrive Technology
Automation and Drives
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
SINAMICS G120
System/ProduktA&D Drive technology
24.4.2006, Page 3© Siemens AG 2006 - Subject to change without notice
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
Service
SINAMICS G120: The innovative and modular drive joins the SINAMICS family
… for small and medium power ranges with Safety Integrated, Communication & Regeneration feedback
G120
G120
G120
SIEMENSDrive Technology
Automation and Drives
System/ProduktA&D Drive technology
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
Service
The new, modular frequency inverter with innovative
functions for Safety Integrated, Communication and Energy
Regeneration. The basis for future application- or industry
oriented products.
SINAMICS G120 –Overview
SINAMICS G120
Automation and Drives
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
SINAMICS G120
System/ProduktA&D Drive technology
24.4.2006, Page 5© Siemens AG 2006 - Subject to change without notice
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
Service
SINAMICS G120 addresses new markets thanks to the innovative technology
2006 2007 2008
Turnover
MM4
G120First system components
available
Most of the system components
available
Additional G120 business volume with respect to MM4
MM4 is and remains our main vehicle to provide cost-optimized solutions
SINAMICS G120 –Overview
Automation and Drives
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
SINAMICS G120
System/ProduktA&D Drive technology
24.4.2006, Page 6© Siemens AG 2006 - Subject to change without notice
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
Service
SINAMICS G120 The high-performance single-motor drive
Blocksize
Power range: 0.37 kW – 75 kW (CT/HO)0.37 kW – 90 kW (VT/LO)
Voltage: 3ph 400VSoon: 3ph 690V
SINAMICS G120 –Overview
Automation and Drives
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
SINAMICS G120
System/ProduktA&D Drive technology
24.4.2006, Page 7© Siemens AG 2006 - Subject to change without notice
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
Service
SINAMICS G120 Power Modules PM240 / PM250 / PM260
A&D Antriebstechnik PM240 (3-ph. 400VAC 0.37 – 75kW CT(HO*) / 90kW VT(LO*))
Framesizes A-C: Dimensions similar to MICROMASTER 440 Framesizes D-F: More compact than MICROMASTER 440From 2.2kW integrated filter A ( only for TN line supplies )Integrated braking chopperIP20NEW: Safety Integrated support
PM250 (3-ph. 400VAC 5.5 – 75kW CT / 90kW VT)
* HO = High overloadLO = Light overload
FSF45-75kW
FSD15-22kW
FSE30-37kW
FSB2,2-4kW
FSC5,5-11kW
Multi-purpose Power Module concept(A-type filter integrated / no line reactor)NEW: Energy Regeneration into the line supply
LC Filter integratedSilicium Carbid IGBT‘s
PM260 (3AC 690V 7,5 – 37kW CT / 45kW VT) (Sales release 12/06)
Power Module
Automation and Drives
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
SINAMICS G120
System/ProduktA&D Drive technology
24.4.2006, Page 8© Siemens AG 2006 - Subject to change without notice
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
Service
SINAMICS G120 Control Units CU240S / CU240E
incl. Safety Integrated, Profisafe
PROFIBUS with DIP for SUB-D
6 DIN
2 DIN fail-safe (4 DI‘s, 2 DI‘s per function)
... otherwise the sameas CU240S
CU240S DP-F
PTC / KTY
TTL / HTL encoder
Slot for MMC
V/f, Vector control based on MM440 with various versions
PROFINETPROFIBUS with DIP for SUB-D
RS485 / USS (SUB-D)
Cost optimizedversion forapplications withfewer hardwarerequirements
9 DIN
3 DOUT (24V relay)
2 AIN (mA or V)
2 AOU (mA or V)
CU240ECU240S PNCU240S DPCU240S
Picture of CU240STyp
RS485 / USS (SUB-D)
Control Units
Automation and Drives
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
SINAMICS G120
System/ProduktA&D Drive technology
24.4.2006, Page 9© Siemens AG 2006 - Subject to change without notice
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
Service
Communication overview with the variousSINAMICS G120 control units
PROFINET
PROFIBUS DP
RS485/USS
RS232/USS*
*) with the option: PC Connection Kit
CU240E CU240SCU240S
DPand
240S DP-F
CU240S PN
Communication
Automation and Drives
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
SINAMICS G120
System/ProduktA&D Drive technology
24.4.2006, Page 10© Siemens AG 2006 - Subject to change without notice
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
Service
SINAMICS G120 accessories
Line reactorsOutput reactorsAdditional line filterBraking resistorsMMC memory cardBOP operator panel (compatible to the G110)PC connection kit (RS232)
including the STARTER engineering toolBrake relay for an electro-mechanical brakeSafe brake relay for electro-mechanical brakeMounting rail adapterShield connecting plates
At a later time:NEMA1 kitsLC output filter
Additional details are provided in the Manual or PRODIS or in the internet SINAMICS G120 Link
Options
Automation and Drives
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
SINAMICS G120
System/ProduktA&D Drive technology
24.4.2006, Page 11© Siemens AG 2006 - Subject to change without notice
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
Service
Safety
User protection
Machine protection
Autonomous monitoring
Continuous monitoring
Energy regenerat.
Energy saving
Add. Cooling not required
Continuous braking
Line-friendly
PROFINET
Simple handling
High performance
Unified
Integrated into IT
Cooling concept
High ruggedness
Consequential separation
Reliable
High lifetime
Modularity
Asset management
Higher degree of innovation
Flexibly expandable
SINAMICS G120 – innovative functions
Customer benefits
Automation and Drives
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
SINAMICS G120
System/ProduktA&D Drive technology
24.4.2006, Page 12© Siemens AG 2006 - Subject to change without notice
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
Service
Safety Integrated
• The drive speed is reduced and simultaneously monitored
• Independ., continuous monitoring
• An encoder is not required
• Safely Limited Speed
• According to EN 60204
• By using failsafe DI or PROFISAVE Profil
• Drive is quickly stopped and moni-tored in a safety-relevant fashion
• Independent and continuous monitoring guarantees the shortest response times when a fault condition develops
• An encoder is not required
• Safe Stop 1
• According to EN 60204
• By using failsafe DI or PROFISAVE Profil
• Prevents the drive from undesirably starting
• Drive is safely switched into a Safe Torque Off condition
• No circuit breaker required between motor and drive
• Safe Torque Off
• According to EN 60204
• By using failsafe DI or PROFISAVE Profil
• No electrical isolation needed to ensure stop functionality
Customer benefitsFunctionFeature
Category 3 of EN954-1 and SIL 2 of IEC 61508
Competition: The Safe Stop and Safe Limited Speed functions integrated in G120 are unique – and that worldwide!
Customer benefits
Additionally included: Safe Brake Control (the secure control of an external braking module).
Automation and Drives
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
SINAMICS G120
System/ProduktA&D Drive technology
24.4.2006, Page 13© Siemens AG 2006 - Subject to change without notice
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
Service
Modularity
• All combinations are possible• Optimized asset management• Only the required functions are
actually paid for
• Minimum learning required
• Drive unit does not have to re-commissioned - just plug-on CU
• Permanent high degree of innovation of the drive inverter
• Just the PM and CU are replaced – a new complete installation is not required
• Power Unit and Control Unit can be freely combined
• System to help select the optimum units
• Modules can be replaced under voltage (hot swapping)
• Fast innovation cycles as a result of optimized development
• Service friendly
Customer benefitsFunctionFeature
Drive units from our competitors require separate drive inverter series or components. This new type of scalability of our drive units is absolutely unique in this price class!
Applications: a simple scalability for a drive system e.g. by an OEM-application
Customer benefits
Automation and Drives
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
SINAMICS G120
System/ProduktA&D Drive technology
24.4.2006, Page 14© Siemens AG 2006 - Subject to change without notice
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
Service
Tools
Unified engineering with SIZER andSTARTER over the complete SINAMICS family
SINAMICS drives are engineered with SIZER
SINAMICS drives are commissioned with STARTER.
SIZER and STARTER offer a unified and standard look&feel and data integration
STARTER can be fully integrated into Siemens engineering systems
Drive ESSTEP7
SIMOTION SCOUT
SINAMICS distinguishes itself as a result of the standard and unified engineering
Automation and Drives
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
SINAMICS G120
System/ProduktA&D Drive technology
24.4.2006, Page 15© Siemens AG 2006 - Subject to change without notice
SIEMENS Drive Technology
SINAMICS G120 -Overview
Power Modules
Control Units
Communication
Techn. Data
Options
Customer benefits
Tools
Service
SINAMICS G120
The new, modular frequency inverter with innovative functions for Safety Integrated, Communication and
Energy Regeneration. The basis for future application- orindustry oriented products.