EPC ENERGY AND POWER CONVERSION...

44
www.epcas.com.tr 1 EPC ENERGY AND POWER CONVERSION SYSTEMS EPC was established by executives who have long years of experience in the power electronics field and is growing rapidly while ranking among the top players of the industry. EPC Energy, with its customized solutions has become the first choice of many customers. EPC produces the fastest and best solutions, as well as the most appropriate products for the needs of its customers and business partners. Power-One in telecommunications power supplies and Solar On-Grid Inverters, Liebert in UPS’s, Rocket, Vision, Kokam, Enersys and Fiam in batteries. TDK-Lamda in SMPS’s are some of our business partners.

Transcript of EPC ENERGY AND POWER CONVERSION...

Page 1: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr1

EPC ENERGY AND POWER CONVERSION SYSTEMS

EPC was established by executives who have long years of experience in the power electronics field

and is growing rapidly while ranking among the top players of the industry.

EPC Energy, with its customized solutions has become the first choice of many customers. EPC produces

the fastest and best solutions, as well as the most appropriate products for the needs of its customers

and business partners.

Power-One in telecommunications power supplies and Solar On-Grid Inverters, Liebert in UPS’s, Rocket,

Vision, Kokam, Enersys and Fiam in batteries. TDK-Lamda in SMPS’s are some of our business partners.

Page 2: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr 2

Index345679

1011121314161819202223242526272829303132333435363738394041424344

Research and Development / High Quality

After Sale Support / Export

References

SD Series 1 Phase Rectifiers

SD Series 3 Phase Rectifiers

BR Series Rectifier / Uninterruptible, DC Energy

STS Series 1 Phase Static Transfer Switches

STS Series 3 Phase Static Transfer Switches

HI-RECT Series Rectifier / Battery Charger

FC Series Static Frequency Converters

GC Series Uninterruptible Power Suplies

INVERTA Series Static Power Inverters

INV Series Power Inverter

SVR Series Static Voltage Regulator

OVR Series Automatic Voltage Regulator

PL Series Uninterruptible Power Supplies

PLT Series Uninterruptible Power Supplies

PLRM300/30 Series Modüler Online UPS

PLRM600/30X Series Modüler Online UPS

PLRM200/20 Series Modüler Online UPS

PLRM060/20B Series Modüler Online UPS

PLMPT Series Uninterruptible Power Supplies

PLMST Series Uninterruptible Power Supplies

PLI33 Series Tower Online UPS

SLI22 Series Tower Online UPS

SLI11/31 Series Tower Online UPS

SLI11 Series Tower Online UPS

SLIR11 Series Tower Online UPS

HS Series Line Interactive UPS

SLT200 Series Uninterruptible Power Supplies

SLT300 Series Uninterruptible Power Supplies

Electronic DC Load Automatic Battery Discharger

VRLA Series Battery

Kokam Series Battery

Ni-Cd Alcad Series Battery

Integrated Solutions

Solar Systems

Dealer & Service

Page 3: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr3

High quality is our first principle therefore we choose providers delicately.

EPC Energy works with companies sales high quality products which has

Local and international certificates.

Our products are tested and controlled in many ways and all has the

quality certificates of ISO 9001-2000 and ISO 14001.

Because of the speed of technology in order to compete and make

difference, R&D is important for our company. EPC Energy spends 10%

of own sources for R&D. Our goal is to become a world wide power

electronic company.

Research and Development

High Quality

Page 4: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr 4

Technical support service...7 days 24 hours uninterrupted on our products.

After Sale Support

We manufature and sale to other countries as; Germany, Denmark, Holland, Jordan, Iraq, Nigeria and others...

Export

Page 5: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr5

ReferencesABB Turkey AGDAS TurkeyALARKO TurkeyALPHA TurkeyALPHA TECHNOLOGIES CanadaALSTOM TurkeyANEL Turkey ANDRİTZ HYDRO Turkey ARTRONIC TurkeyASELSAN Turkey BOTAŞ Turkey CENGIZ ENERJİ TurkeyÇALIK ENERJİ TurkeyDIGITURK Turkey ENEL Turkey ENERJI SA TurkeyENKA & INTERGEN TurkeyESA GRIMMA GermanyETI ALIMINYUM Turkey EXXON MOBIL Global FCG TurkeyGAMA TurkeyGENERAL ELECTRIC Turkey GES ELECTRIC Turkey INFORM AS Turkey IMTECH Netherland

ISDEMIR TurkeyISS GermanyJOULZ NetherlandKARADENİZ ENERJI TurkeyKARSAN (PEUGEOT) TurkeyKESİR MÜHENDİSLİK TurkeyKMD TurkeyLAFARGE Turkey MAKELSAN TurkeyMAXIMUM POWER JordanNECRON TurkeyOPERATIF Turkey OZDISAN TurkeyPOWER ELECTRIC TurkeyPOWIN UsaREJMAN CO. IraqSAVRONİK A.Ş. Turkey SIEMENS TurkeyTAQA Abu DhabiTEIAS TurkeyTENNET NetherlandTOFAS (FIAT) Turkey TURKISH NAVY TurkeyTURKCELL Turkey ULUSOY ELECTRIC TurkeyUNIMEX Denmark

Page 6: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr6

SD Series / 1 Phase

RectifiersGENERAL SPESIFICAITIONS

1 phase input (model dependent) Internal isolation transformer at input Full controlled conventional rectifier Smart control and high reliability with DSP (Digital Signal Processor) Float charge, equalizing charge and boost charge modes Automatic and manual charge modes Low output voltage ripple and high reliability 2x16 character LCD display, showing measurements, status and alarm messages Soft start Led displays for easy observation of Rectifier status. Audible alarm. Programmable current limitation Operation as voltage source or current source Calibration of measurements from front panel Language selection from front panel

(English / German / Turkish / Netherland / Portuguse) DC Low / High, Line Failure, Over Temperature, Short Circuit protections Ability to program all operation parameters (password protected) Programable alarm relay contact outputs (4 standart, up to 16 relays as option) Possibility of monitor and control over RS232-RS485.

Modbus communication. *Option Log records with date and time stamp up the 200 events. Earth leakage monitoring *Option Ability to monitor batteries and battery low alarm,

even when the AC input fails (option) Battery temperature compensation *Option 12 pulse option to limit input current distortion. *Option Active parallel (current sharing) operation up to 4 devices *Option Easy observation via analog gauges

(Input / Output / Battery Voltages / Currents) *Option Battery test with adjustable voltage and duration *Option Transducers for input / output voltage(s) / current(s) (4-20mA and 0-10V) *Option Internal cabinet light. *Option Internal cabinet anticondensation heater. *Option 24 V / 48 V / 110 V / 220 V output options

TECHNICAL SPECIFICATIONSMODEL 1 PHASE INPuTINPuTNominal Voltage 110V / 115V / 208V / 220V / 240VNominal frequency 50 or 60 HzTransformer Galvanically isolatedITHD <45-50% standardInput Protection Thermic Magnetic Overcurrent protection MCB, Overvoltage protectionOuTPuTFloating Output Voltage 12 VDC / 24 VDC / 48 VDC / 110 VDC / 220 VDC

Output Voltage Adjustment 12/24VDC output: 10VDC to 30VDC, 48VDC output: 40VDC to 60VDC, 110VDC output 80VDC to 150VDC, 220VDC output: 190VDC to 290VDC

Output Current Adjustment 0-100% of Nominal Output CurrentBattery Charger Current Adjustment 0-100% of Nominal Output Current

Bost Charger Voltage 100% to 120% of Floating Output CurrentBost Voltage(V/C) 2,4 lead acid battery 1,60 NiCd BatteryFloat Voltage(V/C) 2,24 lead acid battery 1,40 NiCd BatteryNominal Output Current 30A/60A/100AMax Output Current 100 % of nominal output currentFiltering L-C FilterGENERALBost Timer 0-600 hours adjustableCooling Forced fans with smart fan controlling systemIsolation Voltage 1500 or 3000VAC input/chassis and output/chassisEfficiency at full load >80%Protection level IP20 (Standard); IP54 (Optional)Cable Entry Front BottomAccess to Batteries Batteries and rectifier in the same cabinet with front access (optional)Circuit Breakers Thermic-magnetic circuit breakers for input, Battery and Load (up to 100A)Reset Button Used for re-operation in case of fallure of the system.DISPLAY PANELMeasurements LCD Display for Load Output Voltage/Current, Battery Output Voltage/Current and Line Voltage/Line Current/FrequencyButtons Timer Settings, Boost Voltage Setting, Float Voltage Setting, Output Current Setting, Battery Current Setting and Reset buttons.Time and Date AdjustableCharger Failure Open or closed free contactsLow Battery Open or closed free contactsRectifier over voltage Open or closed free contactsOver temperature Open or closed free contactsLine Failure Open or closed free contactsCOMMuNICATION & PARALLELING

Communication Standard RS232 communication on real time base for remote monitoring and control. Optional RS485 / Modbus

Paralleling Parallel Redundant (No need for extra kit for paralleling)NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications.All names used above are registered trademarks of their respective owners.

Page 7: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr 7

SD Series / 3 Phase

RectifiersGENERAL SPESIFICAITIONS

3 phase input (model dependent) Internal isolation transformer at input Full controlled conventional rectifier Smart control and high reliability with

DSP (Digital Signal Processor) Float charge, equalizing charge and boost charge modes Automatic and manual charge modes Low output voltage ripple and high reliability 2x16 character LCD display, showing measurements,

status and alarm messages Soft start Led displays for easy observation of Rectifier status.

Audible alarm. Programmable current limitation Operation as voltage source or current source Calibration of measurements from front panel Language selection from front panel

(English / German / Turkish / Netherland / Portuguse) DC Low / High, Line Failure, Over Temperature,

Short Circuit protections Ability to program all operation parameters

(password protected) Programable alarm relay contact outputs

(4 standart, up to 16 relays as option) Possibility of monitor and control over RS232-RS485.

Modbus communication. *Option Log records with date and time stamp up the 200 events. Earth leakage monitoring *Option Ability to monitor batteries and battery low alarm,

even when the AC input fails (option) Battery temperature compensation *Option 12 pulse option to limit input current distortion. *Option Active parallel (current sharing) operation up to

4 devices *Option Easy observation via analog gauges (Input / Output /

Battery Voltages / Currents) *Option Battery test with adjustable voltage and duration

*Option Transducers for input / output voltage(s) / current(s)

(4-20mA and 0-10V) *Option Internal cabinet light. *Option Internal cabinet anticondensation heater. *Option 24 V / 48 V / 110 V / 220 V output options

Page 8: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr8

SD Series / 3 Phase

Rectifiers

TECHNICAL SPECIFICATIONSMODEL 3 PHASE INPuT

INPuT

Nominal Voltage 110V / 115V / 208V / 220V / 240V

Nominal frequency 50 or 60 Hz

Transformer Galvanically isolated

ITHD <8*-30% standard (* 12 pulse)

Input Protection Thermic Magnetic Overcurrent protection MCB, Overvoltage protection

OuTPuT

Floating Output Voltage 12 VDC / 24 VDC / 48 VDC / 110 VDC / 220 VDC

Output Voltage Adjustment12/24VDC output: 10VDC to 30VDC, 48VDC output: 40VDC to 60VDC,

110VDC output 80VDC to 150VDC, 220VDC output: 190VDC to 290VDCOutput Current Adjustment 0-100% of Nominal Output CurrentBattery Charger Current Adjustment

0-100% of Nominal Output Current

Bost Charger Voltage 100% to 120% of Floating Output Current

Bost Voltage(V/C) 2,4 lead acid battery 1,60 NiCd Battery

Float Voltage(V/C) 2,24 lead acid battery 1,40 NiCd Battery

Nominal Output Current 30A/60A/100A

Max Output Current 100 % of nominal output current

Filtering LC Filter

GENERAL

Bost Timer 0-99.9 hours adjustable

Cooling Forced fans with smart fan controlling system

Isolation Voltage 1500 or 3000VAC input/chassis and output/chassis

Efficiency at full load >85%

Protection level IP20 (Standard); IP54 (Optional)

Cable Entry Front Bottom

Access to Batteries Batteries and rectifier in the same cabinet with front access (optional)

Circuit Breakers Thermic-magnetic circuit breakers for input, Battery and Load (up to 100A)

Reset Button Used for re-operation in case of fallure of the system.

DISPLAY PANEL

Measurements LCD Display for Load Output Voltage / Current, Battery Output Voltage /

Buttons Current and Line Voltage / Line Current / Frequency

Time and Date Timer Settings, Boost Voltage Setting, Float Voltage Setting, Output

Charger Failure Current Setting, Battery Current Setting and Reset buttons.

Low Battery Adjustable

Rectifier over voltage Open or closed free contacts

Over temperature Open or closed free contacts

Line Failure Open or closed free contacts

COMMuNICATION & PARALLELING

Communication Open or closed free contacts

Paralleling Open or closed free contacts

OPTIONS & ACCESSORIES

Communication Standard RS232 communication on real time base for remote monitoring and control. Optional RS485 / Modbus

Paralleling Parallel Redundant (No need for extra kit for paralleling)NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Page 9: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr 9

BR SeriesRectifier / Uninterruptible, DC Energy

GENERAL SPESIFICAITIONS

Ergonomic design for easy mounting

Dry-type maintenance-free battery

Constant voltage charging

and Working Principle

Microprocessor control with

controlled battery test button

Wide input voltage tolerance UPS, DC Power

TECHNICAL SPECIFICATIONS

MODELS BR 24 V BR 110 VINPuTNumber of Input Phase Single PhasePhase Input Voltage Range 90-265 VAC 176-265 VACInput Frequency 50 HzIngress Protection 2 amp fusePower factor >0.80OuTPuTOutput Voltage 24VDC 110VDCRated Output Current 7AMPMaximum Output Current 300% InominalOutput Protection Electronic short-circuit protection and 10 fusesCooling Natural or forced (with fan)GENERAL SPECIFICATIONSEfficiency >85% >87%Operating Temperature 0- 50ºCRelative humidity 5% - 90%Input / Output Connections KlemensCabinet Protection Class IP 20STANDARDSEMC EN61204-3Safety EN60335-1NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Page 10: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr10

STS Series / 1 Phase

Static Transfer SwitchesGENERAL SPESIFICAITIONS

1 phase models Smart control and high reliability with DSP (Digital Signal Processor) Thyristor controlled switching (fully static) Automatic and manual transfer modes 2x16 character LCD display, showing measurements,

status and alarm messages Graphic touchscreen user interface module (HMI) Option Led displays for easy observation of static transfer switch status. Audible alarm. Led test Internal maintenance bypass switch Internal, redundant and monitored power supplies Calibration of measurements from front panel Language selection from front panel

(English / German / Turkish / Netherland / Portuguse) Input Low / High, Output Low / High, Over Temperature,

Short Circuit protections Ability to program all operation parameters (password protected) Common alarm relay output Possibility of monitor and control over RS232-RS485.

Modbus (RTU) communication. Log records with date and time stamp up the 200 events. Thyristor failure detection Natural cooling up to a power level 4 programable alarm relay contact outputs Option Easy observation via analog gauges (input / output voltages / currents) Option Transducers for input / output voltage(s) / current(s) (4-20mA and 0-10V) Option Internal cabinet light. Option Internal cabinet anticondensation heater. Option

TECHNICAL SPECIFICATIONSMODELS STS 1016 STS 1032 STS 1050 STS 1063 STS 1100 STS 1150POWER (A) 16 32 50 63 100 160INPuTInput Voltage 110V / 120V / 220V / 230V / 240VNominal frequency 50 or 60 HzOuTPuTOutput VoltageINFO FOR INSTALLATONWeight (kg) 12 kg 16 kg 20 kgDimension (wdh) (mm)(3 pole)

19 inch rack cabinet,Height: 2U, Depth: 400mm

19 inch rack cabinet,Height: 4U, Depth: 400mm

Operation tempereture -5°C - 50°CStorage tempereture -20°C - 70°COverload Capability 150 % for 1 minutes, 250% 20 mili secondAcceptable Source Voltage Distortion 10 % MaximumMax altitude 2000mCommunication Modbus Communication over RS232 Serial PortDry Contact 1 Dry contact output dedicated for common alarm, 4Dry (optional)Colour RAL5004, other colours are optionalProtection level IP20Efficiency > 98%Transfer Time < 5ms @ 50 Hz, < 4,1ms @ 60 HzADDITIONAL FEATuRESCabinet On Cabinet Maintenance SwitchCommunication Modbus Communication over RS232 Line (RS485 Optional)Time- Date Log Records up to 200 logs with Real Time Clock Calender

Led Indicators (Source1 Good, Source2 Good, Source1 On, Source2 On, Output OK, Common Alarm, Source1 Maint, Sourc2 Maint, Syncronisation Bad)

Power Supplies Redundant Internal Power SuppliesAlarm Audible Alarm

Current Function Load High Current Inhibit Function, which inhibits emergency transfer in case of very high currents like short circuits

Relay Output Dry Contact Relay Output for Common AlarmNOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

IEC 13 Output Socket - Two Way

Size 1U Double Pole

Connector Input / Output

LCD PanelKeypad &

Communication DSPControl

ThyristorStaticSwitch

Output

Source 2

Source 1

Measurement &Freedback

Maintenance Bypass Circuit Breaker

Measurement &Freedback

Page 11: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr 11

STS Series / 3 Phase

Static Transfer SwitchesGENERAL SPESIFICAITIONS

3 phase models Smart control and high reliability with

DSP (Digital Signal Processor) Thyristor controlled switching (fully static) Automatic and manual transfer modes 2x16 character LCD display, showing measurements,

status and alarm messages Graphic touchscreen user interface module (HMI) Option Led displays for easy observation of static

transfer switch status. Audible alarm. Led test Internal maintenance bypass switch Internal, redundant and monitored power supplies Calibration of measurements from front panel Language selection from front panel

(English / German / Turkish / Netherland / Portuguse) Input Low / High, Output Low / High, Over Temperature,

Short Circuit protections Ability to program all operation parameters (password protected) Common alarm relay output Possibility of monitor and control over RS232-RS485.

Modbus (RTU) communication. Log records with date and time stamp up the 200 events. Thyristor failure detection Natural cooling up to a power level 4 programable alarm relay contact outputs Option Easy observation via analog gauges

(input / output voltages / currents) Option Transducers for input / output voltage(s) / current(s)

(4-20mA and 0-10V) Option Internal cabinet light. Option Internal cabinet anticondensation heater. Option

TECHNICAL SPECIFICATIONSMODELS STS 3050 STS 3100 STS 3150 STS 3200 STS 3300 STS 3400 STS 3500 STS 3600POWER (A) 50 100 150 200 300 400 500 600INPuTNominal Voltage-sources 380-400-415 Vac three-phase with neutralVoltage tolerance 180/264 Vac (adjustable)Switched input phases 3(3-pole) - 3+N(4-pole) (optional)Nominal frequency 50 or 60 HzInput frequency tolerance range (+ or -) 10 % ( adjustable)Distribution compatibility IT, TT, TNS, TNCOPERATING FEATuRESTransfer type “Break Before Make” (no overlapping sources)Avaliable transfer methods Automatic/Manual/Remote

Transfer time for source failure < 1/4 cycle (5.0ms @ 50Hz, 4.1ms @ 60Hz) (S1/S2 synchronised and adjustable) 10 msec (S1/S2 NON synchronised)

ENVIRONMENTALEfficiency at full load (%) > 99 %Noise level at 1 m from front (dba) (from 0 to full load)-(dba) 55 55 55 65 65 65 65 65

Storage tempereture 20°C up to 70°CAmbient tempereture (-5°C) - (50°C)Relative humidity 95% non-condensingMax installation height 1000m at rated power (-1% power for every 100m above 1000m)-Max 4000mReference Standards EN 62310-1 (safety) EN 62310-2 (electro-magnetic compatibility)Weight (kg) 100 110 120 140 250 290 350 400Dimension (wdh) (mm) (3 pole) 450x500x1000 600x600x1200 700x1000x1600Colour RAL7035, other colours are optionalProtection level IP20 up to IP54ADDITIONAL FEATuRESCabinet On Cabinet Maintenance SwitchCommunication Modbus Communication over RS232 Line (RS485 Optional)Time- Date Log Records up to 200 logs with Real Time Clock Calender

Led Indicators (Source1 Good, Source2 Good, Source1 On, Source2 On, Output OK, Common Alarm, Source1 Maint, Sourc2 Maint, Syncro-nisation Bad)

Power Supplies Redundant Internal Power SuppliesAlarm Audible Alarm

Current Function Load High Current Inhibit Function, which inhibits emergency transfer incase of very high currents like short circuits

5 Dry Contact Relay Outputs (1 for common alarm, 4 programmable)NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Page 12: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr12

HI-RECT SeriesRectifier / Battery Charger

TECHNICAL SPECIFICATIONSINPuTVoltage 1-Phase 220Vac, 3-Phase 220/380 VacVoltage Tolerance ± 15%Frequency 50/60 Hz.Frequency Tolerance ±10%Power Factor 1-Phase: 0.98 (THD 4%) / 3-Phae: 0.92 (THD 30%)OuTPuTVoltage 24,48,100,220Vdc, -10% ... +35% (front panel selectable)Current 15, 30, 60, 100A (4000* and 12000W**)

Current Limiting I nom x 102%front panel selectable between 0 and 102%

Ripple <0,5%Voltage Regulation ±0.5 % at float charge, ±1% at boost chargeEfficiency 3- Phase: >92% / 1- Phase: >85%

Protections Input, output (thermal/magnetic) fuses, Advanced short circuit protection,Overvoltage protection, Overcurrent protection, Automatic restart

BATTERYBattery Charge Modes(Adjustable Charging voltages) Automatic charge, boost charge: 2,4 V / Cell Float Charge: 2.25 V / Cell Incrementable by 1 hour up to 24 hours

Boost Charge Time Incrementable by 1 hour up to 24 hours

LCD Properties 2x16 character-wide display, showing:Output voltage & current, Output voltage high/low Load(%), Log Records up to 200 logs with Real Time Clock Calender AC (AC available), Fault, Current limiting,

Displays Automatic charge, Float charge, Boost charge, Common alarmAlarms Common relay contact output for AC input low, DC output low and overheatOperation and control Via menu selections from buttons on front panel

Endurable Dielectric Voltage2000 V Input-Output 2000 V Input-Chasis

500 V Output - Chasis (For PS with output voltage <50 V)1000 V Output - Chasis (For PS with output voltage >50 V)

GENERAL FETuRESCase Dimensions (WxDxH) 3-Phase: 19’’ rack cabinet 54 / 1-Phase: 19’’ 54 or wallmountProtection Class IP20Audible Noise 1m. 50dBACooling Mandatory cooling (Fan)

Weight 1- Phase PS < 20 kg3- Phase PS < 30 kg

Operation Temperature OºC.....40ºCStoring Temperature -20ºC... 70ºCRelative Humidity 98% (Non-condensing)STANDARDSStandards VDE,DIN 41773 (Battery charge characteristics) ANSI-NEMA PE 5 TS 2000 EN 62040-1, 2,NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

GENERAL SPESIFICAITIONS 1 phase or 3 phase input (model dependent) Internal isolation transformer at input Full controlled conventional rectifier Smart control and high reliability with DSP (Digital Signal Processor) Float charge, equalizing charge and boost charge modes Automatic and manual charge modes Low output voltage ripple and high reliability 2x16 character LCD display, showing measurements,

status and alarm messages Soft start Led displays for easy observation of Rectifier status. Audible alarm. Programmable current limitation Operation as voltage source or current source Calibration of measurements from front panel Language selection from front panel

(English / German / Turkish / Netherland / Portuguse) DC Low / High, Line Failure, Over Temperature, Short Circuit protections Ability to program all operation parameters (password protected) Programable alarm relay contact outputs

(4 standart, up to 16 relays as option) Possibility of monitor and control over RS232-RS485.

Modbus communication. *Option Log records with date and time stamp up the 200 events. Earth leakage monitoring *Option Ability to monitor batteries and battery low alarm,

even when the AC input fails (option) Battery temperature compensation *Option 12 pulse option to limit input current distortion. *Option Active parallel (current sharing) operation up to 4 devices *Option Easy observation via analog gauges

(input / output / battery voltages / currents) *Option Battery test with adjustable voltage and duration *Option Transducers for input / output voltage(s) / current(s)

(4-20mA and 0-10V) *Option Internal cabinet light. *Option Internal cabinet anticondensation heater. *Option 24 V / 48 V / 110 V / 220 V output options

Page 13: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr 13

FC SeriesStatic Frequency Converters

GENERAL SPESIFICAITIONS 3 Phase full sinus output waveform 50 Hz, 60Hz, 83 1/3 Hz, 400 Hz output frequency Internal isolation transformer at output Ability to drive nonlineer loads Reliable IPM (Intelligent Power Module) techology IGBT DSP (Digital Signal Processor) control Space Vector Control technology 2x16 / 4x20 Character LCD display for monitoring an

adjustments Audible alarm Programmable dry contact outputs and Modbus

communication Adjustable switching frequency Advanced pc program for PC connection Ability to set up / adjust all operational parameters

through front panel and PC commuication Input, Output over voltage, over current, short circuit,

over temperature protections Ability of control via external digital input or

communication Programmable automatic restart Ability of cold start and battery operation

TECHNICAL SPECIFICATIONSINPuT

Voltage 380 Vac / 400Vac / 420Vac / +10% -15% 3Ph+N 4W (3Ph - 3W Optional)

Frequency 50Hz / 60Hz Automatic Selectable ±10 %

Power Factor < 0.8

Technology 6 pulse or 12 pulse full bridge fectifier

OuTPuT

VoltageSingle phase out 115 - 120 - 200 - 220 - 230 Vac +N

Three phase out 115 / 200 Vac - 120 / 208 Vac - 220 / 380 Vac ±1%230 / 400 Vac - 240 / 400 Vac ± 1% with or without neutral

Power 10kVA to 400kVA

Frequency 50 Hz / 60Hz / 83 1/3 Hz / 400 Hz ± 1%

Power Factor 0.8

Crest Factor 3:1

Total Harmonic Distortion <3 % with linear load

Efficiency >88 - 93%

Technology Space Vector Control

MEASuREMANTS& ALARMS & INDICATORS

Measurements

Output Voltage (3 phase)Output Current (3 phase)

DC Bus VoltageDC Bus Current

Protections & Alarm -Warning Messages

Output Low / HighDC Bus Low / High Too low

Overload / OvercurrentOver Temperature

Short Circuit / IGBT OvercurrentMemory / DSP Error

Led IndicatorsInput OKOperation

Common AlarmGENERAL

Protection Class IP20 (Higher IP Class Optional)

Cooling Forced cooling with fan

Color RAL 7032 (other colors optional)

Cable Inlet Bottom (topinlet optional)

Mounting Floor

ENVIROMENTAL CHARACTERISTICS

Operation Temperature -5 ºC to + 50 ºC

Storage Temperature -20 ºC to +70 ºC

Relative Humidity 0-90% Non condensing

Operation Altitude 0 -1000 mNOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Page 14: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr14

GC SeriesUninterruptible Power Suplies

GENERAL SPESIFICAITIONS DC or AC, or DC and AC inputs 3phase sine wave output Input and output 50Hz, 60Hz, 831/3Hz, 400Hz frequency

optional. Output isolated transformer On Non-lineer loads (computer and switching power supplies)

excellent performance Galvanic insulation Intelligent Power Module or IGBT technology full reliability. DSP (Digital Signal Processor) control. Space-vector control technology Low output distortion factor. High efficiency. With an LCD display (2x16 / 4x20) all parameters

can be programmed and monitored tucscroeh panel (option) Audible alarm Programmable dry relay outputs and Modbus communication. Pulse with modulation technology (PWM) All parameters can be adjusted on Display Input and output low and high voltage protection,

over temperature protection abilities User freindly control panel Remote control interface, central control,

PC or modem connection International and local certificated 2 years warranty Automatically start and fault recovery Input/output power and power factor measurement

GC Series UPS single line diagram

Page 15: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr 15

GC SeriesUninterruptible Power Suplies

TECHNICAL SPECIFICATIONSINPuTNominal input voltage (V) 400 [380 / 415]Input phases 3 ph + NInput voltage tolerance (%) +15 / -10Maximum input voltage (transient state) (%) +/-20Nominal frequency (Hz) 50 / 60 (selectable)Tolerance on frequency (%) +10 / -10Rectifier type 6-pulse thyristorsInput current distortion at full load and in battery recharge mode (%) 30Soft start (s) 10(adj)Isolation transformer Standard (except 400Vdc rectifiers)Maximum recommended voltage distortion (THD) from Mains (or generator) on the input of the rectifier (%) 7OuTPuTDC voltage stability (%) < +/- 1DC voltage ripple in float (with battery connected) (% rms) 1Rectifier-charger current limitation (in floating, charge or boost) I nominalINVERTER OuTPuTNominal output voltage 110,120 or 220,230,240 Vac before chosing)Nominal output frequency (Hz) 50 / 60 [selectable]Overload at cos phi = 0.8 (%) 125 (10 min) / 150 (1 min)Short circuit capacity (%) 250 (100 ms) / 175 (5 s)Isolating transformer Standard on the complete rangeVoltage stability (for 100% load variation): Static (%) +/- 1Dynamic (%) +/- 5 (recovery time < 20ms)Frequency response (Hz/s) 0.1Frequency stability: with own oscillator (%) +/- 0.05with mains synchronisation (%) +/- 5 [adjustable from 0.2 to 5]Harmonic voltage distortion: with 100% linear loadwith 100% non linear load (%) According to IEC 62040-1-2Synchronisation voltage limits (%) +/- 5Output crest factor admissible 3/1Load power factor 06 lag to 0.9 leadSYSTEM DATAExternal protection degree IP 20Internal protection degree IP 20Cable entry BottomAccess FrontSystem design life (years) 20ENVIRONMENTAL DATAOperating temperature (°C) -5 to 45 (permanent operation)Storage temperature (°C) -20 to +70Maximum relative humidity (non condensing) (%) <95Operating altitude 1000 m (without system derating)NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Page 16: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr16

INVERTA SeriesStatic Power Inverters

GENERAL SPESIFICAITIONS DSP controlled 1 or 3 phase output Input and output brakers 1kVA / 600kVA power options Output isolated transformer 50Hz / 60Hz / 83 1/3 Hz / 400 Hz output frequency 50 Hz / 60 Hz adjustable frequency on the same device Perfect dynamic answer By-Pass input connection and uninterruptable

by-pass option Compatible with inrush current devices

(motors and compressors and etc…) Short circuit protection Parallel working and scaling (options) 2 x 16 character LCD display, monitoring the output,

input voltage and current Line voltage low, high, output voltage high, low,

over temperature and IGBT/Mosfet fault and alarms Through RS232 or RS485 Modbus communication

(options). Through RS232 communication advanced

PC control and monitoring program Monitoring and controlling the all operational

parameters by means of the LCD display Automatic or manual start Language selection on LCD Log records up to 200 evants Controlling with an external input Soft start LED’s on the front panel Standing or rack-type cabinet Voltage & Current Transducers Minimum IP20 protection class Relay output

Page 17: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr 17

INVERTA SeriesStatic Power Inverters

TECHNICAL SPECIFICATIONS

24VDC INPuT ELECTRICAL

SPECIFICATIONS

Power 1500 VA 2500 VA

DC Input Voltage 20-40 VDC 20-40 VDC

DC Input Current 75 A 121 A

Output Voltage 230 Vac or 3*400 V+N

Output Frequency 6.5 Aac 10.8 Aac

Crest Factor 50/60Hz 50/60Hz

Surge Capacity for 5 seconds 2.5:1 2.5:1

Power Factor 0.75 (1125) 0.75 (1875)

Voltage THD <3 % <3 %

Efficiency > 84 % > 85 %

48VDC INPuT ELECTRICAL

SPECIFICATIONS

Power 2000 VA 3000 VA 5000 VA

DC Input Voltage 40-80 VDC 40-80 VDC 40-80 VDC

DC Input Current 48 A 71 A 121 A

Output Voltage 230 Vac or 3*230 Vac+N

Output Current 8.7 Aac / 5Av 13.0 Aac / 7.5A 21.7 Aac / 12A

Output Frequency 50/60Hz 50/60Hz 50/60Hz

Crest Factor 3:1 2:1 2:1

Surge Capacity for 5 seconds 16 A 24 A 25 A

Power Factor 0.75 (1500) 0.75 (2250) 0.75 (3750)

Voltage THD <3 % <3 % <3 %

Efficiency > 86 % > 86 % > 86 %

GENERAL & ENVIROMENTALSPECIFICATIONS

Operation Temperature 0°C - 60°C

Storage Temperature (-)20°C - 70°C

Relative Humidity 0-90 % non - condensing

Colling Method Fan fanced

Protection Degree IP 20

Display & Indicators 2*16 character LCD display Output OK & Input OK &Common Alarm Leds Output & Input Fuse

Alarms & Protections DC Undervoltage & Overvoltage Overload Short Circuit & IPM Fault Over Temperature

NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

110VDC INPuT ELECTRICAL

SPECIFICATIONS

Power 2000 VA 3000 VA 4000 VA 5000 VA

DC Input Voltage 90-140 VDC 90-140 VDC 90-140 VDC 90-140 VDC

DC Input Current 21 A 29 A 41 A 50 A

Output Voltage 230Vac or 3*230 Vac+N

Output Current 8.7 Aac/5A 13.0 Aac/7.5A 17.4 Aac/10A 21.7 Aac/12A

Output Frequency 50/60Hz 50/60Hz 50/60Hz 50/60Hz

Crest Factor 3:1 3:1 3:1 3:1

Surge Capacity for 5 seconds 39 A 50 A 80 A 100 A

Power Factor 0.75 (1500) 0.75 (2250) 0.75 (3000) 0.75 (3750)

Voltage THD <3 % <3 % <3 % <3 %

Efficiency > 86 % > 90 % > 90 % > 91 %

Page 18: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr18

INV SeriesPower Inverter

GENERAL SPESIFICAITIONS

CPU control technology

SPWM technology with pure sine wave

Powerful load capability and high compatibility

Advanced reverse noise technology

Settable to AC model and DC model

Fault protection

Interface: RJ45, dry contact

TECHNICAL SPECIFICATIONSMODEL HS 500Technical Specifications (VA) 0.5K 1K 2K 3K 4K 5K 6K 7K 8K 10KDC INPuTInput Voltage (Vdc) See chart3Input current (A) See chart3Input range of Voltage (Vdc) See chart3Reflected Noise Current ≤10%AC BYPASSBypass Volt (Vac) 260V-180V(±10V)Input Current A 2.3 4.5 9.1 13.6 18.2 22.7 27.3 31.8 36.4 45.4Transfer Time (ms) ≤5 ≤5MS MSAC OuTPuTRated Capacity (VA) 500 1K 2K 3K 4K 5K 6K 7K 8K 10KOutput Power (W) 400 800 1600 2400 3200 3500 4200 4900 5600 7000Voltage and Frequency 220Vac , 50HZOutput Current (A) 1.8 3.6 7.2 10.8 14.5 16 19.1 22.3 25.4 31.8Voltage Precision (V) 220±1.5%Frequency Precision (Hz) 50±0.1%Output wave Pure Sine WaveWave Distortion(THD) (Resistant Load) ≤3% (Linear Load)Dynamic Reaction Time(Load 0 <---> 100%) 5% (load 0 <---> 100%)

Power Factor (PF) 0.8/0.7Overload 120% , 30sInversion Efficiency(80% Resistant Load) ≥85%

Transfer Time (ms) ≤5msENVIRONMENTIsolation (IN/OUT) 1500Vac , 1minNoise (1m) ≤40dBTemperature -20 ~+50Humidity 0~90% , Non-condensingSea Level (m) ≤2000SHOwLCD Input and Output Voltage, Frequency, Output Current, TemperatureInverter Status Power Normal, Inverter Normal, Battery Voltage, Output OverloadMECHANICALStandard Rack DxWxH (mm) See IVS9000 Series Mechanical propertiesWeight (kg) See IVS9000 Series Mechanical propertiesProtection Function Input Low/High Voltage, Output Overload/Shortage, Reversed Input Connecting Protection

12 Series 24 Series 48 Series 110 Series 220 SeriesRated Input Voltage (Vdc) 12V 24V 48V 110V 220V

Dc Input Voltage Range (Vdc)

Turn-off Voltage10V - 15V

Turn-off Voltage20V - 30V

Turn-off Voltage40V - 60V

Turn-off Voltage90V - 139V

Turn-off Voltage208V - 260V

Turn-off Voltage11V - 14V

Turn-off Voltage22V - 28V

Turn-off Voltage45,5V - 57V

Turn-off Voltage104V - 131V

Turn-off Voltage208V - 260V

Rated Input Current (A)

500VA 42 500VA 21 500VA 10 500VA 5 500VA 21KVA 83 1KVA 42 1KVA 21 1KVA 9 1KVA 5

-- -- 2KVA 83 2KVA 42 2KVA 18 2KVA 9-- -- 2.5KVA 104 3KVA 63 3KVA 27 3KVA 14-- -- -- -- 4KVA 83 4KVA 36 4KVA 18-- -- -- -- 5KVA 104 5KVA 45 5KVA 23-- -- -- -- 6KVA 125 6KVA 55 6KVA 27-- -- -- -- 7KVA 146 7KVA 64 7KVA 32-- -- -- -- 8KVA 167 -- -- 8KVA 36-- -- -- -- 10KVA 210 -- -- 10KVA 45

NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Page 19: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr 19

SVR SeriesStatic Voltage Regulator

TECHNICAL SPECIFICATIONSINPuT 315 320 330 345 360 375 390 3120 3150 3200 3250 3300 3400 3500

Power 15 KVA 22.5 KVA 30 KVA 45 KVA 60 KVA 75 KVA 90 KVA 120 KVA 150 KVA 200 KVA 250 KVA 300 KVA 400 KVA 500 KVA2000 KVA

Power Factor 0.85INPuTInput Voltage 380 VAC 3 Phase + NeutralInput Voltage Tolerance 276 VAC - 430 VAC (155 - 480 VAC optional)Input Frequency 50 Hz. +/- %5Input Connection Suitable terminalOuTPuTOutput Voltage 380 VACOutput Voltage Tolerance +/-%2Output Current 19 A 29 A 38 A 58 A 78 A 96 A 116 A 155 A 195 A 257 A 320 A 385 A 510 A -Over Load %101 - %125 Load 3 Min. %126 - %150 Load 10 Sec %151 Load 1 Sec. Output OffOutput Frequency 50-60 Hz. ± % 5Regulation Speed Min. 500 V / secEffiency Min. - % 90Output Connection Suitable terminal With 4x16 Character LCD Display:

LCD DisplayInput Voltage, Output Voltage, % Output Load, Output Frequency Regulator Condilion and Failure

Infos, Overload, Over Temperature, Input Failure warning ext.Communication RS-232 Communication Port and SNMP Monitoring Port and Sorfware (optional)PROTECTIONOutput Voltage Protection When Output Voltage Out of 310 VAC - 395 VAC Tolerance Values, Output off with contactorCurrent Protection Input /output protection with MCBPhase Protection (Op.) If these is Input phase sequence tailure, cuts off out (optional)BY-PASS

Surge ArresterManuel by - pass for tailure and maintanence (15 kVA and up)

Suitable Surge Arrester Unit for lightining andHigh Voltage (optinal)

RFI Filter / RFI Filter HARMONIC FILTER can be used to eliminate input high frequency noises and harmonicHARMONIC Filter Current (optinal)Isolation Transformer Input and output Isolation Transformer for special usage (optional)GENERALMaximum Temperature 0º ± 40ºCAltutide 2000 mHummudity %95 non condensedAcoustic Noise <50 dBDimension (WxDxH) cm 36x80x73 55x80x120 95x75x162 105x80x200 -NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

GENERAL SPESIFICAITIONS 15 - 2000 kVA power interval as 3 phase Safe use for all the sensitive electrical devices Control and protection unit with microprocessor based boards Regulation between 160 V AC - 250 V AC (90 VAC-280 VAC optional) 500 V / sec voltage regulation rate Static and modular structure with Thyristor and SMPS technology High efficiency, silent operation LCD front panel Maintanence free design which can not be effected from dust, hummudity or vibration In case of defect, ON/OFF and by-pass switch to operate from network CONTACTOR unit for LOW - HIGH voltage at output and for the first opening delay Produced with high quality equipments to obtain minimum failure risk User freindley front panel Surge Arrester against to high current and lightining (optional) Isolation transformer (optional) Harmonic filter (optional) RFI filter (optional) Production with ISO-9001:2000, 14001 Quality Management System 2 years warranty 10 years spare part warranty Technical service support

Page 20: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr20

OVR SeriesAutomatic Voltage Regulator

GENERAL SPESIFICAITIONS 1% or better output voltage regulation High efficiency High reliability Modular construction for east customization Continuous voltage regulation-not crude

step regulation Regulation on each phase Load balancing for Applications with un-balanced

and fluctuating utility power Monitor and manage output voltage and set points External maintenance by-pass Short circuit and over load protection Ability to work with non-linear loads Easy, front panel Access for service / Installation Noise Attenuation 10 Years Spare parts availability guarantee Compatible with ISO9001 and CE standards Reliable technical service support

Options Offer more features and functionality Wide input voltage range Advanced LCD panel providing detailed

information Microprocessor controlled Optional RS232 Communication for remote

monitoring and control

TECHNICAL SPECIFICATIONSINPuT OuTPuT

MODELSPOwER (KVA)

VOLTAGEVOLTAGE

TOLERANSMAX

CuRRENTVOLTAGE

VOLTAGETOLERANS

MAX CuRRENT

RESPONSE V/SN

EFFICIENCY (%)

TEK FAZ

OVR-0201 2

220 Vac1 Phase

160-245 VacPhase - Notr

10 A

220 Vac1 Phase

±2 % (Ops.)±3 % (Ops.)±5 % (Ops.)

7 A ≥ 95OVR-3501 3.5 17.5 A 13 A

≥ 96

OVR-0501 5 25 A 18 AOVR-0751 7.5 37.5 A 27 AOVR-1001 10 50 A 36 AOVR-1501 15 75 A 55 AOVR-2001 20 100 A 73 A

40OVR-3001 30 150 A 109 A

ÜÇ FAZ

OVR-0603 6

380 Vac 3 Phase

160-245 VacPhase - Notr

277-424 VacPhase - Faz

10 A

380 / 220Vac 3 Phase

±2 % (Ops.)±3 % (Ops.)±5 % (Ops.)

7.3 A

80

≥ 95OVR-1053 10.5 17.5 A 12.7 A

≥ 96OVR-1503 15 25 A 18.3 AOVR-2253 22.5 37.5 A 27.3 AOVR-3003 30 50 A 36.4 AOVR-4503 45 75 A 54.5 A

≥ 97

OVR-6003 60 100 A 73 A

40

OVR-7503 75 125 A 91 AOVR-9003 90 150 A 110 A

OVR-11003 110 183 A 133 AOVR-12003 120 200 A 146 AOVR-15003 150 250 A 182 AOVR-22003 220 367 A 267 AOVR-27003 270 450 A 327 AOVR-33003 330 550 A 400 AOVR-36003 360 600 A 436 AOVR-40003 400 667 A 485 AOVR-50003 500 833 A 610 AOVR-60003 600 1000 A 727 AOVR-65003 650 1084 A 788 AOVR-90003 900 1500 A 1091 A

OVR-100003 1000 1667 A 1212 ANoise Level < 50 dB (1 meter away)

Front Panel Functions Output Voltage V (analog) “Regulator Working” warning (light) Maintenance By-Pass to select Network Controller with Switch

NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Page 21: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr 21

PL SeriesUninterruptible Power Supplies

GENERAL SPESIFICAITIONS True On-line Topology / Sinusoidal Output IGBT / IPM Technology (İnverter Side) Thyristor Control Rectifier 6 or 12 pulse application Galvanic Isolation at the Output of the Inverter Static and Maintenance By-Pass Advanced Automatic and Manual Battery Test System Non-Linear Load Driving Capability RS232 and Dry Contacts or RS485, Modbus

Communication and Remote Monitoring. High Efficiency up to 94%. Space Vector Application. High Performance Design. Overload and Short Circuit Protection. Utility&Generator Friendly Compatible with International Standards Flexi Power Walk-In Temperature Compensated Battery Charging Hot Standby Configuration Advanced 2x16 or 4x20 LCD Panel Providing Detailed)

Information (Input/Output Voltage, Battery Voltage, Charging Current, Interior Temperature and Setting User Selectable Parameters)

200 Recorded Event History. Alarm Logging. Compact and Quiet. ISO9001, ISO14001 Certified 10-Years Spare Parts Availability Guarantee Year-Round 24-Hour Emergency Technical Support

Options: Parallel Aplication Touching Display IGBT Rectifier

TECHNICAL SPECIFICATIONSMODELS 310 315 320 330 340 360 380 3100 3120 3160 3200 3250 3300 3400 3500Power kVA 10 15 20 30 40 60 80 100 120 160 200 250 300 400 500INPuTInput Voltage 127/220 Vac or 230/400 Vac or 220V/380Vac 3 phase + NeutralInput Voltage Range 127/220 Vac or 230/400V +10%,-15% or 220/380Vac +10%,-15%Input Frequency 50 Hz±%5 or 60Hz±%5OuTPuTPower (kW) 8 12 16 24 32 48 64 80 96 128 160 200 240 320 400Power Factor 0.8Output Voltage 120/208 Vac or 230 / 400 Vac, 220 / 380 Vac 3 phase + NeutralVoltage Stability (Balanced load: ± %1) (Unbalanced load: ± %2.5) (Step load: ± %5)Correction Time After step load: Max 25 ms.Frequency 50 Hz or 60Hz Frequency Tolerance Adjustable + % 2 (synchronous) , +%0.2 (free operation)Efficiency of %100 Load 87-91% 90-92% 92-94%Total Harmonic <%3 (for linear loads)Distortion <%7 (for non-linear loads)Crest Factor 3:1Excessive Load Protection (100% 125% load: 10min.) (125% 150% load: 1min.) (>150% load: by-pass)Short Circuit Protection Short circuit protection electronicallyBATTERYType Maintenance free lead-acid Battery Number 10 or 20 or 30 or 32 30 or 32Charge Voltage (Vdc) 135 / 270 / 405 / 432 405 / 432 / 540 Discharge Voltage (Vdc) 102 / 204 / 300 / 320 300 / 320 /480Ambient Temperature 25°CBattery Test Automatic or manualGENERALSeries Communication Dry contact and RS232 or RS485, ModbusSoftware Management softwareOperating Temperature Interval 0°C-40°CCooling Forced coolingRelative Humidity >90% condensingOperating Height <1000m from sea levelAcoustic Noise <56dBA <60dBA <65dBA <70dBAWeight Without Battery 235 250 266 322 484 562 620 770 810 960 1300 1450 1650 2400* 2500*

Dimensions (mm) (HxWxD) 1145 x 485 x 675 1400 x 700 x 800 800 x 800 x 2000 1900 x 1260 x 830 1900 x 2520

x 830APPLICATION STANDARDSEMC, Safety IEC62040-1, IEC62040-2Protection Class IP20Quality Assurance ISO14001 - ISO9001 certifiedOPTIONSInput Transformer Isolated transformer at the input.Input Harmonic Distortion THD* %5 (12 pulse rectifier and filter)Input Power Factor** 0.90 (With additional filter or 12 pulse rectifier and filter)MBS Full isolation with maintenance by-passOperating In Parallel 1+3 system (Standby, Current sharing, Parallel Redundant)(*) 12 pulsed rectifier(**) There can be a change in standard dimensions or additional filter or 12 pulsed rectifier and filter applications.NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Page 22: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr22

PLT SeriesUninterruptible Power Supplies

GENERAL SPESIFICAITIONS Transformerless UPS topology Low input current

total harmonic distortion (THD) High input power factor High efficiency up to 94% Cold Start function Static and maintenance by-pass switch Output short circuit

and overload protection External REPO switch input 192 events memory

(192 events 4500 alarms) Clock and calendar (battery supported) Automatic battery test,

remaining battery time indicator Temperature compansated

charge system Regenerative backfeed function 2 RS232 serial ports and

12 dry contact outputs 3 DSP controlled modular structure Optional SNMP and MODBUS adaptors

Optional graphical and touch panel 2 years warranty 10 years spare parts support Manufactured according to

EC Drictive; EN62040 Full digital structure Small footprint Economode operation Fewer electronic components Output current limiting Advanced diagnostics for the input Selectable input/output coltage /

frequencyy / range Split by-pass input (second unput) Output DC leakage protection Seperate DSP for inverter control Seperate DSP for the PFC 3 level battery protection High charge current capacity Charge / discharge current indicator Advanced remote control features

TECHNICAL SPECIFICATIONSMODELS PLT 310 PLT 315 PLT 320 PLT 330 PLT 340 PLT 360 PLT 380 PLT 3100 PLT 3120Power kVA 10 15 20 30 40 60 80 100 120INPuTPower factor / THDI > 0,98 / < 5 %Voltage 380 - 400 VAC 3 Phase + Wiress + Earth ± 20% (240 / 415VAC + 15%, -25%)Frequency 50 Hz / 60Hz selectable ±%5By-pass Voltage 380 - 400 VAC 3 Phase , 4 Wiress ± 20%By-pass Protection Short circuit, Voltage tolerance, Frequency tolerance, VAT transferVoltage Distortion < 10%Protection Fuses, Voltage & Frequency tolerance, Input power limit, Input PFCOuTPuTPower (kW) 9 13,5 18 27 36 54 72 90 108Power Factor 0.9Voltage 380-400 Vac 3 phase + Wiress + Earth ±1%Frequency 50 Hz / 60Hz selectableFrequency tolerance Line synchronized: ± 2 % / Free running: ± 0,2% (adjustable)Efficiency up to 94%Crest Factor 3:1Overload protection 100% - 125 % load: 10 min., 125% - 150 % load: 1 min., - > 150% load: by pass (adjustable)Other protection Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limitingTHD (at 100% linear load) <3%BATTERYType Sealed Acid - Maintenance FreeNumber of Battery 2x30 (±30): 60 batteriesFloat Charging Voltage 2 x 405 VDCEnd of Discharge Voltage 2 x 300 VDCBattery Cabinet Internal ExternalBattery ambient temp. 25 °CProtections 3 level alarms, Battery fuses, Charging current limit, Temperature compensationAutomatic testing Stardard every 72 hours (adjustable)GENERALRegulations EN62040-2User Interface 4 lines LCD panel, Mimic leds, 5 vector buttons, buzzer, optional graphical touch-panelIndicators P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service TimeAdvanced Self diagnostics, 4 maintenance time indicators, Calibration over RS232Communication 2 x RS232 serial ports, 4 standard and 8 optional DRY contact alarm reaysInputs EPO input, Interactive battery panel input, Genset InputGensel kit Standard (programmable)Software Standard T-Mon UPS Management Software (3 clients + 1 server management)Alarm logging Standard: with time & date 192 events, (optional) 512 eventsProtections Power module over-temperature, Over current, Temperature high alarmTemperature range 0 °C - 40 °CProtection Degree IP20Humidity / Altitude 90% max (noncondensed) / <1000 m above sea levelAcoustic Noise <57 dBA <62 dBA <64 dBA <68 dBAWeight Without Battery 87 87 91 100 173 180 194 216 216Dimensions (mm) (HxWxD) 400x815x1035 515x850x1440 775x910x1900OPTIONSInput 110 / 208 VACOutput 110 / 208 VACTransformer Galvanic isolation transformer at the input & outputSoftware T-mon Admin Multi UPS monitoring, T-Mon Server 50-100-200 clients, DLOG log loaderAdaptors SNMP, MODBUS, RS485, Remote PanelParallel Operation available 1+1 / N +1 (up to 4) 2014 NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Page 23: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr 23

PLT SeriesUninterruptible Power Supplies

TECHNICAL SPECIFICATIONSMODELS PL T 3200 PL T 3250 PL T 3300 PL T 3400 PL T 3500

Power (kVA) 200 250 300 400 500

INPuT

Voltage 380/400 VAC 3 Phase + N + E ± 20% (415 VAC +15 %, +250 % optional)

Frequency 50 Hz. / 60 Hz. selectable, ±5%

Power Factor > 0.99

Harmonic Current Distortion (THDI) < 4 %

By pass Voltage 380 / 400 VAC 3 Phase + N , 4 Wires, ± 10%

Voltage Distortions < 10 %

Protection Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator

OuTPuT

Power (kW) 180 225 270 360 400

Power Factor 0,9 0,8

Voltage 380/400 VAC 3 Phase + N ± 1% (415 VAC optional)

Frequency 50 Hz. / 60 Hz. selectable

Frequency Tolerance Line synchronized: ± 2 % / Free running: ± 0,1 % (adjustable)

Efficiency up to 95%

Crest Factor 3:1

Overland Protection 100% - 125% load: 10 min., 125% - 150% load: 1 min, - >150% load: by pass

Other Protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting

THD (at 100% Linear Load) < 3 %

BATTERY

Type VRLA AGM / GEL / NICd

Nominal Voltage ± 360 VDC

Float / End of Discharge Voltage ± 405 VDC / ± 300 VDC

Battery Cabinet External

Battery Ambient Tempereture 25 ºC

Protections 3 Level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)

Automatic Testing Standard every 72 hours (adjustable)

GENERAL

Standards EN62040-1, EN62040-2

User Interface TFT PANEL, 5 vector buttons, Buzzer,

Indicators P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time

Advanced Self diagnostics, 3 maintenance time indicators, Calibration over RS 232, operating hour meter

Communication 2xRS232 serial ports 4 standard and 8 optional DRY contact alarm relays

Inputs EPO input, interactive battery panel input, Gensel input

Gensel Kit Standard T-mon UPS Management Software (3 clients + 1 server management)

Software Standard: with time & date 512 events

Alarm Logging Power module over-temperature, Over current, Temperature high alarm

Protections 0 ºC - 40 ºC

Temperature Range IP20

Protection Degree 90% max. (noncondensed)

Relative Humidity < 1000m. above sea level

Altitude

Acoustic Noise < 68 dBA < 72 dBA

Weight Without Batters (Kg) 482 550 638 737 780

Dimensions (Mm) Hxwxd 1900x880x775 1900x1250x775 2020x1250x775

OPTIONS

Different Input / Output Voltage Please ask

Transformer Galvanic isolation transformer at the input & output

Software T-mon Admin Multi UPS monitoring 10-50-100-200 clients, T-mon Server 50-100-200 clients

Adaptors SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP),USB Alarm Logger, TCP/IP, GSM/GPRS Modem. Comport multiplexer

Paralel Operations up to 8

NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Page 24: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr24

PLRM300/30 Series Modular Online UPS

GENERAL SPESIFICAITIONS Modular design with N+X redundancy ,online hot-swappable High power density with footprints of less than 2m up to 900KVA

in parallel, 30KVA power module with only 3U height Green and energy saving: AC/AC efficiency>95%,

input power factor>0.99 while input THDi<3% Full DSP control of high stability, reliability and safety Integrated IGBT module with improved performance and reduced size Excellent input performances for complete compatibility with input

PF of 99% and wide range of voltage Self-Aging mode for full load test with less than 10%

of the total power capacity needed Smart Sleeping mode for energy saving and prolong

the life time of the system Optimized battery management, intelligently control the whole process

of the charging and discharging Effectively improve the life time of the battery Battery cold start, UPS can be powered on from

the battery without utility Automatically record the critical wave information when fault happens,

easy for trouble shooting Monitor runtime of critical components, such as fans and capacitors,

settable alarm for service period Independent LCD display for each power module

with self-starting function Programmable dry contacts, the function of each port can be

defined by users Friendly human machine interface with colorful touch

screen of 10.4 inches

TECHNICAL SPECIFICATIONS

MODELS PLRM300/30X

PLRM250/25X

PLRM180/30X

PLRM150/25X

PLRML200/20X

PLRML150/15X

PLRML120/20X

PLRML90/15X

Power Rating 30~300kVAMAIN INPuTGrid System 3 Phases + Neutral + GroundRated Input Voltage 380/400/415VAC (Line-Line)Rated Frequency 50/60Hz

Input Voltage Range 304~478Vac (Line-Line), full load 228V~304Vac (Line-Line),load decrease linearly according to the min phase voltage

Input Frequency Range 40Hz~70HzInput Power Factor >0.99Input Current THDi <3% (full Linear Load)BYPASS INPuTRated Bypass Voltage 380/400/415VAC (Line-Line)Rated Frequency 50/60Hz

Bypass Voltage RangeSelectable, default -20%~+15%

Up limited: +10%, +15%, +20%, +25% Down limited: -10%, -15%, -20%, -30%, -40%

Bypass Frequency Range Selectable, ±1Hz, ±3Hz, ±5Hz

Bypass Overload 110% Long term operation / 110%~125% for 5min 125%~150% for 1min / 150%~400% for 1s / >400% ,less than 200ms

OuTPuTRated Inverter Voltage 380/400/415VAC (Line-Line)Rated Frequency 50/60HzOutput Power Factor 0,9Voltage Precision ±1.5%(0-100% linear load)Transient Response <5% for step load (20% - 80% -20%)Transient recovery < 30ms for step load (0% - 100% -0%)Output Voltage THDu <1% from 0% to 100% linear load<6% full non-linear load according to IEC/EN62040-3Inverter Overload 110%, 60min; / 125%,10min; / 150%,1min; / >150%,200msFrequency Regulation 50/60Hz±0.1%Synchronized Range Settable, ±0.5Hz ~±5Hz, default ±3HzSynchronized Slew Rate Settable, 0.5Hz/S ~ 3Hz/S, default 0.5Hz/SBATTERY AND CHARGERBattery Rate Voltage ±240VDCCharger Voltage Precision 1%Charger Power Max=20%EFFICIENCYNormal Operation >95%Battery Operation >95%ECO Opetation >99%SYSTEMDisplay LED + LCD + Touch screenInterface Standard:RS232, RS485, USB,Dry Contact Option: SNMP,AS/400ENVIRONMENTALOperation Temperature 0 ~ 40 ºCStorage Temperature -40 ~ 70 ºCRelative Humidity 0~95% Non condencingNoise (1 meter) 65dB @ 100% load, 62dB @ 45% loadAltitude <1000m, Load derated 1% per 100m From 1000~2000mPHISICAL DATAModule Dimension WxDxH,mm 460x790x134Module Weight kg 34Cabinet Dimension WxDxH,mm 600x1100x2000Cabinet Weigh kg 220NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Page 25: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr 25

PLRM600/30X Series Modular Online UPS

GENERAL SPESIFICAITIONS Modular design with N+X redundancy ,online hot-swappable High power density of 600KVA in one single cabinet,

30KVA power module with only 3U height Green and energy saving: AC/AC efficiency>95%,

input power factor>0.99 while input THDi<3% Full DSP control of high stability, reliability and safety Integrated IGBT module with improved performance

and reduced size Self-Aging mode for full load test with less than 10%

of the total power capacity needed Smart Sleeping mode for energy saving and prolong

the life time of the system Optimized battery management, intelligently control

the whole process of the charging and discharging, effectively improve the life time of the battery

Battery cold start, UPS can be powered on from the battery without utility

Automatically record the information when faults happen, easy for trouble shooting

Monitor runtime of critical components, such as fans and capacitors, settable alarm for service period

Independent LCD display for each power module with self-starting function

Programmable dry contacts, the function of each port can be defined by users

Friendly human machine interface with colorful touch screen of 10.4 inches

TECHNICAL SPECIFICATIONSMODELS PLRM 600/30X PLRM 500/25X PLRML 400/20X PLRML 300/15XCapacity 600kVAMAIN INPuTGrid System 3 Phases + Neutral + GroundRated Input Voltage 380/400/415VAC (Line-Line)Rated Frequency 50/60Hz

Input Voltage Range 304~478Vac (Line-Line), full load 228V~304Vac (Line-Line),load decrease linearly according to the min phase voltage

Input Frequency Range 40Hz~70HzInput Power Factor >0.99Input Current THDi <3% (full Linear Load)BYPASS INPuTRated Bypass Voltage 380/400/415VAC (Line-Line)Rated Frequency 50/60Hz

Bypass Voltage RangeSelectable, default -20%~+15%

Up limited: +10%, +15%, +20%, +25%Down limited: -10%, -15%, -20%, -30%, -40%

Bypass Frequency Range Selectable, ±1Hz, ±3Hz, ±5Hz

Bypass Overload 110% Long term operation 110%~125% for 5min 125%~150% for 1min150%~400% for 1s >400% ,less than 200ms

OuTPuTRated Inverter Voltage 380/400/415VAC (Line-Line)Rated Frequency 50/60HzOutput Power Factor 0,9Voltage precision ±1.5%(0-100% linear load)Transient Response <5% for step load (20% - 80% -20%)Transient recovery < 30ms for step load (0% - 100% -0%)Output Voltage THDu <1% from 0% to 100% linear load <6% full non-linear load according to IEC/EN62040-3Inverter Overload 110%, 60min; 125%,10min; 150%,1min; >150%,200msFrequency Regulation 50/60Hz±0.1%Synchronized Range Settable, ±0.5Hz~ ±5Hz, default ±3HzSynchronized Slew Rate Settable, 0.5Hz/S ~ 3Hz/S, default 0.5Hz/SBATTERY AND CHARGERBattery Rate Voltage ±240VDCCharger Voltage precision 1%Charger Power max=20% EFFICIENCYNormal Operation >95%Battery Operation >95%ECO Opetation >99%SYSTEMDisplay LED + LCD + Touch screenInterface Standard:RS232, RS485, USB ,Dry Contact Option: SNMP, AS/400MODELOperation Temperature 0 ~40 ºCStorage Temperature -40 ~70 ºCRelative Humidity 0 ~ 95% Non condencingNoise (1 meter) 65dB @ 100% load, 62dB @ 45% loadAltitude <1000m, Load derated 1% per 100m From 1000 ~ 2000mPHISICAL DATAModule Dimension WxDxH, mm 460x790x134Module Weight kg 34Cabinet Dimension WxDxH, mm 600x1100x2000Cabinet Weigh kg 220NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Page 26: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr26

PLRM200/20 SeriesModular Online UPS

GENERAL SPESIFICAITIONS Modular design with N+X redundancy and online

hot swapping, easy to expand the capacity Full DSP control of high stability, reliability and safety Integrated IGBT module with improved performance

and reduced size Excellent input performances for complete compatibility

with input PF of 99% and wide range of voltage Self-Aging mode for full load test with less than 10%

of the total power capacity needed Smart charging management system, intelligently control

the whole process of the charging and discharging, effectively improve the life time of the battery

Independent charger for batteries, intelligent battery management system

Battery cold start, UPS can be powered on from the battery without utility.

Totally front access, top and bottom cable connection Friendly human machine interface with touch screen

TECHNICAL SPECIFICATIONSMODELS PLRM200/20 PLRML018/06Capacity 10-200kVAMAIN INPUTInput Voltage 380V/400V/415V(line to line) 220V/230V /240V(line to neutral)Input Frequency 50/60HzPower Factor > 0,99Input Voltage Window -40%~+25%Frequency Window 40-70HzBATTERY Battery Voltage ±240 VDCCharger Power 20% PowerCharger Voltage Precision 1%BYPASS Bypass Voltage 380V/400V/415V, three phase 220V/230V/240V, one phaseBypass Voltage Window -20%-+15%, full load, settable

Bypass Overload Capabiltiy 125%, long time operation 125%< load <130%, last for more than 1 hour130%<load<150%,last for more than 6 minutes >1000%, last for more than 100ms

OuTPuTOutput Voltage 380V/400V/415V, three phase 220V/230V/240V, one phaseVoltage Precision ±0.5% (balance load),±1% (unbalance load)Voltage THD (Total Harmonic Distortion) THD<1%(linear load),THD<5%(nonlinear load)Power Factor 0.8Phase Tolerance 120°±0.5° (balance and unalance load)Crest Factor 3:1

Overload Capabiltiy 105%,long time operation, 110%, transfer to bypass after 1hour, 125%, transfer to bypass after 10 minutes, 150%, transfer to bypass after 1 minute, >150%, transfer to bypass after 200ms

SYSTEM

System Efficiency Normal mode: 95%ECO mode: 99%

Battery Mode Efficiency 95%Display LCD+LED, Touch screen and keyboardIP Class IP20Interface (Communication Ports) RS232,RS485,Dry contacts,SNMP card,EPO,Generator interfaceInstallation/Connection Top or bottom cable connectionOperation Temperature 0 - 40 ºCStorage Temperature -25 - 40 ºCRelative Humidity 0-95% (non-comdensing)Noise( db) <55dB

Weight kg

6-module cabinet RM060/10, RM090/15, RM120/20 150 kg10-module cabinet RM100/10, RM150/15, RM200/20 180kg

PM10 10KVA: 20 kgPM15 15KVA: 21 kgPM20 20KVA: 22 kg

Dimension (WxDxH) (mm)6-module cabinet 600*900*160010-module cabinet 600*900*2000

Module 400*600*133 (10KVA/15KVA/20KVA)NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Page 27: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr 27

PLRM060/20B SeriesModular Online UPS

GENERAL SPESIFICAITIONS Modular design with swappable battery package Monitor system for battery Integrated IGBT module with improved

performance and reduced size Easy for installation and maintenance Easy for power expansion and backup time expansion Intelligent protection technology for safe and reliable

hot swappable battery package of the system Smart charging management system,

Intelligently control the whole process of the charging and discharging effectively improve the life time of the battery

Battery cold start, UPS can be powered on from the battery without utility

Friendly human machine interface with touch screen

TECHNICAL SPECIFICATIONS

MODELS

Capacity 10-60kvaMAIN INPuTInput voltage 380V/400V/415V(line to line) 220V/230V/240V(line to neutral)Input frequency 50/60HzPower fator 0.99Input current THD (Total Harmonic Distortion)Input voltage window -40% +25%Frequency window 40 - 70HzBATTERYBattery voltage ±24VDCCharger power 20%*PowerCharger voltage precision 1%BAYPASS

Bypass voltage 380V/400V/415V( line to line)220V/230V/240V (line to neutral)

Bypass voltage window -20% ±15% ~ full load

Pypass overload capability

125%,long time operation125% ~ load ~ 130%, last for more than 1 hour

130% ~ load ~ 150%, last for more than 6 minutes ~ 1000%,last for more than 100ms

OuTPuT

Output voltage 380V/400V/415V(line to line)220V/230V/240V(line to neutral)

Voltage precision 1%(balance load),1.5%(unbalance load)Voltage THDTotal Harmonic Distortion) THD ~1.5%(linear load),THD ~ 5%(nolinear load)

Power fator 0,8Phase tolerance 120°±0.5°(balance and unbalance load)Crest factor 03:01

Overload capability

105%,long time operation110%,transfer to bypass after 1 hour

125%,transfer to bypass after 10 minutes150%,transfer to bypass after 1 minute~150%,transfer to bypass after 200ms

SYSTEM

System efficiency Normal mode:95%ECO mode:98%

Battery mode efficiency 95%Display LED+LCD,Touch screen and keyboardIP class IP20Interface (Communication Ports) RS232, RS485, Dry contacts, SNMP card, EPO, Generator interfcaeInstallation/Connection Top or bottom cable connectionOperation temperature 0 - 40 ºCStorage temperature -25 - 70 ºCRelative humidity 0 - 95% ~ non-condensation)Noise(dB) ~ 55dB

Weight (kg)

RB60 cabinet 200 kgBattery cabinet 220 kg

BM9 9AH:30 kgPM10 10KVA:22 kgPM15 15KVA:22.5 kgPM20 20KVA:22.5 kg

Dimension (WxDxH) (mm) Battery unit 120x723x157Power Module 440x590x134 (10KVA/15KVA/20KVA)

NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

PLRM PLRM PLRM PLRML PLRML PLRML 060/20B 045/15B 030/10B 036/12B 030/10B 018/06B

Page 28: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr28

PLMPT SeriesUninterruptible Power Supplies

GENERAL SPESIFICAITIONS The PLMHT Series from 100 to 600 kVA is the EPC UPS solution for installations requiring high energy efficiency and maximum power availability.PLMHT Series provides maximum protection and power quality for data centres and industrial loads. The UPS has an IGBT-based rectifier, DSP (Digital Signal Processors) technology and provides true On-line, double conversion power protection, (VFI SS 11 - Voltage and Frequency Independent in accordance with IEC EN 62040-3).

Aximised Cost Savings The build specifications offered by the PLMHT range and the exceptional level of efficiency help to absorb the TCO, from the installation stage to daily operation, reducing power costs for the UPS and air conditioning system and installation area costs thanks to its reduced size and weight.Thanks to the ability to monitor the mains input quality and to select the best operating mode based on the interference present (Smart Active mode) or circular redundancy (Parallel Energy Saving mode, which allows the UPS to regulate available

TECHNICAL SPECIFICATIONSMODELS PLMPT 100 PLMPT 120 PLMPT 160 PLMPT 200 PLMPT 250 PLMPT 300 PLMPT 400 PLMPT 500 PLMPT 600INPuTNominal voltage 380 - 400 - 415 Vac three-phaseFrequency 45 - 65 HzPower factor > 0,99Harmonic current distortion <3% THDiSoft start 0 - 100% in 120’’ (selectable)Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)Standard equipment provided Back Feed protection; separable bypass lineBYPASSNominal voltage 360-400-420 Vac three-phase + NNominal frequency 50 or 60 Hz (selectable)OuTPuTNominal power (kVA) 100 120 160 200 250 300 400 500 600Active power (kW) 90 108 144 180 225 270 360 450 540Number of phases 3 + NNominal voltage 380 - 400 - 415 Vac three-phase + N (selectable)Static stability ± 1%Dynamic stability ± 5% in 10 msVoltage distortion < 1% with linear load / < 3% with non-linear loadCrest factor 3:1 lpeack/lrmsFrequency stability on battery 0.05%Frequency 50 or 60 Hz (selectable)Overload 110% for 60’; 125% for 10’; 150% for 1’BATTERIESType VRLA AGM / GEL; NiCd; Supercaps; Li-ion; FlywheelsRipple current ZeroRecharge voltage commpensation -0.5 Vx°CINFO FOR INSTALLATIONWeight (kg) 656 700 800 910 1000 1400 1700 2100 2400Dimensions (WxDxH) (mm) 800 x 850 x 1900 1000 x 850 x 1900 1500 x 1000 x 1900 2100 x 1000 x 1900Remote signals dry contacts (configurable)Remote controls ESD and bypass (configurable)Communications Double RS232 + dry contacts + 2 slots for communications interfaceOperating temperature 0 °C / +40 °CRelative humidity <95% non-condensingColour Dark grey RAL 7016Noise level at 1 m 63 - 68 dBA 70 - 72 dBAIP rating IP20 (others on request)Smart Active efficiency up to 98.5%Standards Safety: EN 62040-1-1 (Directive 2006/95/EC); EMC: EN 62040-2 (Directive 2004/108/EC)Classification in accordancewith IEC 62040-3 (Voltage Frequency Independent) VFI - SS - 111

Moving the UPS transpalletNOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Page 29: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr 29

PLMST SeriesUninterruptible Power Supplies

GENERAL SPESIFICAITIONS

The PLMST Series is ideal for protecting data centre and

telecommunications systems, IT networks and critical systems where

poor power quality can lead to a loss of operations and service.

The PLMST Series is available in 10/12 15/20 kVA models with

three-phase and single-phase input and single-phase output, and

10/12/15/20/30/40/60/80/100/120 kVA models with three-phase input

and output with On-line double conversion technology, according to the

VFI-SS-111 classification, as defined in IEC EN 62040-3.

PLMST Series: designed and built using state of the art technology and

components, and controlled by the DSP microprocessor, to provide

maximum protection to the powered loads with no impact on downsteam

systems and optimise energy savings. Its highly flexible design allows

full compatibility both with three-phase and single-phase power supplies.

TECHNICAL SPECIFICATIONSMODELS PLMST 10 PLMST 12 PLMST 15 PLMST 20INPuTNominal voltage 380-400-415 Vac three-phase with neutral / 220-230-240 single-phaseNominal frequency 50 or 60 HzFrequency tolerance 40 / 72 HzPower factor at full load 0.99Current distortion THDI ≤ 3%BYPASSNominal voltage 220-230-240 VacNumber of phases 1Voltage tolerance 180 / 264 V (selectable)Nominal frequency 50 or 60 Hz (selectable)Frequency tolerance ±5 (selectable)OuTPuTNominal power (kVA) 10 12 15 20Active power (kW) 8 9,6 12 16Power factor 0.8Number of phases 1Nominal voltage (V) 220-230-240 Vac (selectable)Static variation ± 1%Dynamic variation ± 3%Crest factor (Ipeak/Irms) 3 : 1Voltage distortion < 1% with linear load / < 3% with non-linear loadFrequency 50 or 60 HzFrequency stability during battery operation 0.01%

Overload at Pf 0.8 110% for 10 minutes, 133% for 1 minute, 150% for 5 secondsBATTERIESType VRLA AGM / GELCharging time 6 hoursINFO FOR INSTALLATIONWeight withoutinternal batteries (kg) 80/105 82/110 90/115 95/120

Dimensions (WxDxH) (mm) 1320 x 440 x 850Communications 3 slot for communications interface /RS232/USBAmbient temperature 0°C / +40°CRelative humidity 90% non-condensingColour Dark grey RAL 7016Noise level < 52 dBA a 1 mProtection level IP20Smart Active Output up to 98%

RegulationsDirective EMC 2004/108/CE Electromagnetic Compatibility Directive

Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2 C2Classification according to IEC 62040-3 (Voltage Frequency Independent) VFI - SS – 111

NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Page 30: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr30

PLI33 Series Tower Online UPS

GENERAL SPESIFICAITIONS Wide input voltage and frequency range,

compatible with different utility High input PF>0.99 Input Current THDi <3% Full DSP Control Online double conversion technology,

output excellent sinusoidal wave Intelligent battery management, greatly extend

the battery life Full protection, including back feed protection,

battery leakage protection and so on Parallel up to 6 power units Modular design of subsystem, convenient for

field maintenance Friendly Operation Interface, touch LCD Screen

TECHNICAL SPECIFICATIONS

MODELS PLI33010S / PLI33015S PLI33020S / PLI33030S

PLI33010 / PLI33015 / PLI33020 / PLI33030 PLI33040 / PLI33060 / PLI33080 /

PLI33100 PLI33120 / PLI33160 / PLI33200

Capacity 10KVA /15KVA / 20KVA / 30KVA 10KVA / 15KVA / 20KVA / 30KVA / 40KVA / 60KVA / 80KVA / 100KVA / 120KVA / 160KVA / 200KVA

MAIN INPuTInput voltage 380V/400V/415V(line to line), 50/60HzInput connection 3Ph+N+PEPower factor >0.99

Input voltage window +25%~-20%, full load-20%~-40%, power derating between 100% to 70%

Frequency window 40-70HZBYPASSBypass voltage 380V/400V/415VBypass voltage window +15%--20%, full loadFrequency window ±5HzBatteryBattery voltage ±240VDCCharger power 20%*PowerCharger voltage precision 1%OuTPuTVoltage precision 1% (balance load),1.5% (unbalance load)Output voltage transient 5%(0~100% load step)Voltage THD(Total Harmonic Distortion) THD<1%(linear load),THD<5%(nonlinear load)Power Factor 0.8Frequency Tracking Range 50/60Hz±3Hz, adjustableFrequency Precision (Free Running) ±0.02%Phase Tolerance 120°±0.5° (balance and unalance load)Voltage Unbalance Degree (100% Unbalance Load) ±1%Frequency Tracking Speed 0.5Hz/s to 5Hz/s, adjustableCrest Factor 3:1

Overload Capabiltiy102% long time operation 110%, transfer to bypass after 1hour

125%, transfer to bypass after 10 minutes 150%, transfer to bypass after 1 minute>150%, transfer to bypass after 200ms

Bypass Overload Capability 125%, long time operation 125%< load <130%, last for more than 1 hour130%<load<150%,last for more than 6 minutes >1000%, last for more than 100ms

SYSTEM

System Efficiency Normal mode: 95%ECO mode: 99%

Battery Mode Efficiency 95%Battery Configuration 12V, 40PCS (36~44pcs acceptable)Display LCD+LED, keyboardEMI IEC62040-2EMS IEC61000-4-2(ESD), IEC61000-4-3(RS) IEC61000-4-4 (EFT), IEC61000-4-5 (Surge)Insulation resistance >2M (500VDC)Dielectric strengh (input,output to PE)2820Vdc, leakage current lower than 3.5mA, no flashover in 1 minuteSurge protection Comply with IEC60664-1 class IV, endure surge of 1.2/50us + 8/20us higher than 6KV/3KAIP Class IP20Interface (Communication Ports) RS232,RS485,Dry contacts,SNMP card,EPO,Generator interfaceInstallation/Connection Top or bottom cable connectionOperation temperature 0-40º CRelative humidity 0-90% (non-comdensing)Noise(dB) <55dBNet Weight (kg) 97 97.5 97.5 99.5 44 46 46 58 / 186 208 256 278 358 380Pakage Weight (kg) 109 109.5 109.5 110.5 48 50.5 50.5 65 / 204 226 274 292 / /

Dimension(WxDxH) (mm) 540x690x1100(Internal battery)

280x730x668

320x781x788

540x 762x1100

600x855x1350

600x855x1600

600x855x2000

NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Page 31: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr 31

SLI22 SeriesTower Online UPS

GENERAL SPESIFICAITIONS

Wide range of input voltage and frequency

Output PF of 0.8

Full protection of overvoltage, circuit short

and over temperature

Network / fax / modem surge protection

LCD/LED display, monitoring all the operation status

Abundant interface: RS232, USB, SNMP, Intelligent Card

TECHNICAL SPECIFICATIONSMODELS SLI2206S SLI2206L SLI2210LINPuTCold Start YES, default frequency=50Hz or settableAcceptable Input Voltage(Line voltage) 50%~125%(220VAC/230VAC/240VAC) 100% load@80%~125% / 90% load@70%~80% / 80% load@60%~70% / 65% load@50%~60%

Phase Two phase in,two phase out Two phase in,two phase outLine low transfer 110VAC/115VAC/120VACLine low recovery 116VAC/122VAC/127VACLine high transfer 275VAC/288VAC/300VACLine high recovery 268VAC/279VAC/291VACInput Power Factor ≥0.99Input Frequency Range 40Hz - 70Hz Generator Support Any Generator. Support Any Generator.OuTPuTFrequency adaptable SettablePower(kVA) max 6 10Power(kW) max 4,8 8Waveform Pure sine wave Pure sine waveNominal voltage 110/115/120/127VAC 110/115/120/127VACVoltage regulation ± 2 % ± 2%Transient response ≤5% (50% - 100% -50%) ≤5% (50% - 100% -50%)Transient recovery ≤20ms (0% - 100% -0%) ≤20ms (0% - 100% -0%)Voltage distortion ≤2.5% THD, linear load ≤2.5% THD, linear load Output FrequencySynchronization range settable,±3Hz default settable,±3Hz defaultSlew rate 0.5~5Hz/s,2 Hz/s default 0.5~5Hz/s,2Hz/s defaultBattery mode (50±0.05) Hz (50±0.05) HzLine mode with battery full charged 88,0%ECO mode 93,0%Battery mode 87,0%Noise <48dB@<70%load,<58dB@>70%load;1m away <48dB@<70%load,<60dB@>70%load;1m away

Overload Capability (Line Mode) 110%: Transfer to bypass after 10 mins. 130%: Transfer to bypass after 1 min150%: Transfer to bypass after 30s, shutdown after 1 min.(Line mode)

Overload Capability (Battery Mode) 110%: Shutdown after 10mins (Battery mode) 125%:Shutdown after 10s(Battery mode) >125%: Shutdown after 1s (Battery mode)Crest Ratio 3:1BATTERYRating/Type 12VDC/7Ah Depend on the capacity of external batteries Depend on the capacity of external batteriesQuantity 16DC Voltage 192VDC 192/240VDCBack-up Time 4mins @80% load Depend on the capacity of external batteries Depend on the capacity of external batteriesBattery-Low Voltage (176±3)VDC (176±3)VDCCharging voltage (220±1%)VDC (220±1%)VDCCharging current (max) 1A 5A (8A optional) 5A (8A optional)Charging time 7h recharge to 90% Depend on the capacity of external batteries Depend on the capacity of external batteriesLeakage current <1mA <1mAINDICATOR & ALARMDisplay LED+LCD LED+LCDAlarm Sounding once per secondFault Continuous beeping Continuous beepingINTERFACESmart RS232 Standard Cable support EPC Power Monitor SoftwareB type USB(optional) Standard Cable support EPC Power Monitor SoftwareEPO Remoted EPO function for customer. Short to activate

Dry Contactor(optional) DB9 type and phoenix terminal type for selection. (6 output ports, 1 input port) UPS fault alarm, general alarm, bypass mode, UPS normal mode, battery low voltage alarm, utility failure alarm, remoted shutdown.

SNMP(optional) Power Managment from SNMP Manager and Web Browser

Option SNMP, USB, Dry Contactor(AS400),Parallel Kit, ECO Kit, External Battery Cable(standard model), Maintenance Bypass, Maintenance Bypass Detecting Kit

Reserved function Can be designed as deffirent function according to customer's applictionMECHANICALWxDxH (mm) 250*504*945 / 250*589*945Net Weight (kg) 104 65 78NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Page 32: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr32

SLI11/31 SeriesTower Online UPS

GENERAL SPESIFICAITIONS

Wide range of input voltage and high input power factor

Output PF of 0.9

Full protection of overvoltage, circuit short

and over temperature

Network / fax / modem surge protection

LCD display, monitoring all the operation status

Auto fan speed adjustment

Abundant interface: RS232, USB, SNMP, Intelligent Card

TECHNICAL SPECIFICATIONSMODELS SLI 1106S SLI 1106L SLI 1110S SLI 1110L SLI 1115L SLI 1120L SLI 3110L SLI 3115L SLI 3120L

INPuT

Cold Start YES, default frequency=50Hz or settable

Acceptable Input Voltage50%~125%(220VAC/230VAC/240VAC) 50%~125%(380VAC/400VAC/415VAC)

100% load@80%~125% 90% load@70%~80%80% load@60%~70% 65% LOAD@50%~60%

Phase Single phase in,single phase outThree phase

in,single phase out

Single phase in,single phase out Three phase in,single phase out

Transfer Voltage Range line-neutralLine low transferLine high transferLine high recovery

110VAC/115VAC/120VAC275VAC/288VAC/300VAC268VAC/279VAC/291VAC

Input Power Factor ≥0.99 ≥0.98 ≥0.98 ≥0.95 ≥0.95Input Frequency Range 40Hz - 70Hz Generator Support Any Generator

OuTPuT

VOLTAGE

Frequency adaptable SettablePower(kVA) max / (kW) max 6 / 5,4 10 / 9 15 / 13,5 20 / 18 10 / 9 15 / 13,5 20 / 18Waveform Pure sine waveNominal voltage 220/230/240VACVoltage regulation ± 1 %Transient response ≤5% (50% - 100% -50%)Transient recovery ≤15ms (0% - 100% -0%)Voltage distortion ≤1% THD, linear load ≤ 5% THD, non-linear load

OuTPuT

FREQuENCY

Synchronization range settable,±3Hz defaultBattery mode (50±0.05) HzLine mode to battery mode 0Inverter to bypass 4ms 0Line mode with battery full charged 93,0% 93,5% 92,0% 93,5%

ECO mode 98,0% 98,0% 98,0% 98,0%Battery mode 92,0% 92,0% 91,0% 92,0%

Noise <48dB@ <70%load, <58dB@>70%load; 1m away

<48dB@ <70%load, <60dB@>70%load; 1m away

53dB@ <70%load, <66dB@>70%load; 1m away

<48dB@ <70%load, <60dB@>70%load; 1m away

53dB@ <70%load, <66dB@>70%load; 1m away

Overload Capability (Line Mode)

110%: Transfer to bypass after 10 mins. 130%: Transfer to bypass after 1 min 150%: Transfer to bypass after 30s, shutdown after 1 min.(Line mode)

Overload Capability (Battery Mode) 110%: Shutdown after 10mins (Battery mode) 125%:Shutdown after 10s (Battery mode) >125%: Shutdown after 1s (Battery mode)

Crest Ratio 3:1

BATTERY

Rating/Type 12VDC/7AhDepend on the

capacity of external batteries

12VDC/9Ah Depend on the capacity of external batteries

Quantity 16DC Voltage 192VDC 192 / 240 VDC 192VDC 192 / 240 VDC

Back-up Time 4mins @80% loadDepend on the

capacity of external batteries

3.5mins @80% load Depend on the capacity of external batteries

Battery-Low Voltage (176±3)VDCCharging voltage (220±1%)VDCCharging current (max) 1A 5A 1A 5A

Charging time 7h recharge to 90%

Depend on the capacity of external

batteries8h recharge to

90% Depend on the capacity of external batteries

Leakage current <1mA

INDICATOR &

ALARM

Display LED+LCDAlarm Sounding once per secondFault Continuous beeping

INTERFACE

Smart RS232 Standard Cable support EPC Power Monitor SoftwareB type USB (optional) Standard Cable support EPC Power Monitor SoftwareEPO Remoted EPO function for customer. Short to activate

Dry Contactor(optional) DB9 type and phoenix terminal type for selection. (6 output ports, 1 input port) UPS fault alarm, general alarm, bypass mode,UPS normal mode, battery low voltage alarm, utility failure alarm, remoted shutdown.

SNMP(optional) Power Managment from SNMP Manager and Web Browser

Option SNMP, USB, Dry Contactor(AS400),Parallel Kit, ECO Kit, External Battery Cable (standard model), Maintenance Bypass, Maintenance Bypass Detecting Kit

Reserved function Can be designed as deffirent function according to customer's appliction

MECHANICAL WxDxH (cm) 25* 50,4* 64,5 25* 50,4* 48 25* 50,4* 64,5 25* 50,4* 48 25* 50,4* 70,5 25* 50,4* 70,5 25* 50,4* 64,5 25* 50,4* 70,5 25* 50,4* 70,5max 25* 58,8* 64,5 25* 58,8* 48 25* 58,8* 64,5 25* 58,8* 48 25* 56,2* 70,5 25* 56,2* 70,5 25* 58,8* 64,5 25* 56,2* 70,5 25* 56,2* 70,5

NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Page 33: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr 33

SLI11 SeriesTower Online UPS

GENERAL SPESIFICAITIONS

Wide range of input voltage while input PF>99%

Output PF of 0.9, more powerful load capability

Full protection of overvoltage, circuit short

and over temperature

Network / Fax / Modem surge protection

LCD / LED display, monitoring all the operation status

Auto fan speed adjust

Lighting and surge protection

Abundant interface: RS232, USB, SNMP, Intelligent Card

TECHNICAL SPECIFICATIONSMODEL SLI1101S SLI1101L SLI1102S SLI1102L SLI1103S SLI1103L SLIL110800S SLIL110800L SLIL111500S SLIL11500L SLIL112000S SLIL112000L

INPuT

Cold Start YES, default frequency=50Hz or settable

Acceptable Input Voltage 50%~125% (220 / 230 / 240VAC) 50%~125% (380 / 400 / 415VAC)100% load@80%~125% 90% load@70%~80% 80% load@60%~70% 65% load@50%~60%

Line low transferLine low recoveryLine high transferLine high recovery

110VAC/115VAC/120VAC116VAC/122VAC/127VAC275VAC/288VAC/300VAC268VAC/279VAC/291VAC

Input Power Factor ≥0.99 ≥0.99 ≥0.98 ≥0.98 ≥0.95 ≥0.95 ≥0.95Input Frequency Range 40Hz - 70Hz Generator Support Any Generator

OuTPuT VOLTAGE

Frequency adaptable SettablePower(kVA) max 6 10 15 20 10 15 20Power(kW) max 5,4 9 13,5 18 9 13,5 18Waveform Pure sine waveNominal Voltage 220/230/240VACVoltage regulation ± 1 %Transient response ≤5% (50% - 100% -50%)Transient recovery ≤15ms (0% - 100% -0%)

Voltage distortion ≤1% THD, linear load ≤ 5% THD, non-linear load

OuTPuT FREQuENCY

Synchronization Range settable,±3Hz defaultSlew Rate 0.5~5Hz/s,2 Hz/s defaultBattery Mode (50±0.05) HzTransfer TimeLine mode to battery mode 0 0Inverter to Bypass 4MSEfficiencyLine mode with battery full charged 93,0% 93,0% 93,5% 93,5% 92,0% 93,5% 93,5%

ECO mode 98,0% 98,0% 98,0% 98,0% 98,0% 98,0% 98,0%Battery mode 92,0% 92,0% 92,0% 92,0% 91,0% 92,0% 92,0%

Noise <48dB@ <70z%load, <58dB@ >70%load; 1m away

<48dB@ <70%load, <60dB@ >70%load; 1m away

53dB@ <70%load, <66dB@ >70%load; 1m away

<48dB@<70load, <60dB@

>70%load; 1m way53dB@ <70%load, <66dB@

>70%load; 1m away

Overload Capability(Line Mode)

110%: Transfer to bypass after 10 mins.130%: Transfer to bypass after 1 min

150%: Transfer to bypass after 30s, shutdown after 1 min.(Line mode)Overload Capability(Battery Mode) 110%: Shutdown after 10mins (Battery mode) 125%: Shutdown after 10s (Battery mode) >125%: Shutdown after 1s (Battery mode)

Crest Ratio 3:1

BATTERY

RATING/TYPE 12VDC/7AH Depend on the capacity of external batteries 12VDC/9AH Depend on the capacity of external batteries

Quantity 16DC Voltage 192VDC 192/240VDC

Back-up Time 4mins @80% load

Depend on the capacity of external batteries

3.5mins @80% load Depend on the capacity of external batteries

Battery-Low Voltage (176±3)VDC (176±3)VDC (176±3)VDCCharging voltage (220±1%)VDC (220±1%)VDC (220±1%)VDCCharging current (max) 1A 5A 1A 5A

-Charging time 7h recharge to 90%

Depend on the capacity of external batteries

8h recharge to 90% Depend on the capacity of external batteries

LEAKAGE CURRENT <1MA

INDICATOR & ALARM

Display LED+LCDAlarm Sounding once per secondFault Continuous beeping

INTERFACE

Smart RS232 Standard Cable support EPC Power Monitor SoftwareB type USB(optional) Standard Cable support EPC Power Monitor SoftwareEPO Remoted EPO function for customer. Short to activate

Dry Contactor(optional) DB9 type and phoenix terminal type for selection. (6 output ports, 1 input port) UPS fault alarm, general alarm, bypass mode, UPS normal mode, battery low voltage alarm, utility failure alarm, remoted shutdown.

SNMP(optional) Power Managment from SNMP Manager and Web Browser

Option SNMP, USB, Dry Contactor(AS400),Parallel Kit, ECO Kit, External Battery Cable(standard model), Maintenance Bypass, Maintenance Bypass Detecting Kit

Reserved function Can be designed as deffirent function according to customer's appliction

MECHANICAL WxDxH (cm) 25x 50,4x 64,5 25x 50,4x 48 25x 50,4x 64,5 25x 50,4x 48 25x50,4x70,5 25x50,4x70,5 25x50,4x64,5 25x50,4x70,5 25x50,4x70,5max 25x 58,8x 64,5 25x 58,8x 48 25x 58,8x 64,5 25x 58,8x 48 25x56,2x70,5 25x56,2x70,5 25x58,8x64,5 25x56,2x70,5 25x56,2x70,5

NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Page 34: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr34

SLIR11 SeriesRack Online UPS

GENERAL SPESIFICAITIONS

Wide range of input voltage while Input PF>99%

Output PF of 0.9

Full protection of overvoltage, circuit short

and over temperature

Network / Fax / modem surge protection

LCD/LED display, monitoring all the operation status

19 inch standard cabinet and battery cabinet

Automatic fan speed adjustment

Abundant interface: RS232, USB, SNMP, Intelligent Card

TECHNICAL SPECIFICATIONSMODEL SLIR1106L SLIR1106L SLIR1106S SLIR1106S

INPuT

Cold Start YES, default frequency=50Hz or settableAcceptable Input Voltage 50%~125%(220VAC/230VAC/240VAC) 100% load@80%~125%

90% load@70%~80% 80% load@60%~70% 65% load@50%~60%Phase Single phase in,single phase out-Line low transfer 110VAC/115VAC/120VAC

116VAC/122VAC/127VAC275VAC/288VAC/300VAC268VAC/279VAC/291VAC

-Line low recovery-Line high transfer-Line high recoveryInput Power Factor ≥0.99Input Frequency Range 40Hz - 70Hz Generator Support Any Generator

OuTPuT

Frequency adaptable Settable-Power(kVA) max 6 10 6 10-Power(kW) max 5,4 9 5,4 9-Power factor 0,9-Waveform Pure sine wave-Nominal voltage 220/230/240VAC-Voltage regulation ± 1 %-Transient response ≤5% (50% - 100% -50%)-Transient recovery ≤15ms (0% - 100% -0%)-Voltage distortion ≤1% THD, linear load ≤ 5% THD, non-linear load-Synchronization range settable,±3Hz default-Slew rate 0.5~5Hz/s,2Hz/s default-Battery mode (50±0.05) Hz-Line mode to battery mode 0

4ms 0 0.1ms 0

SYSTEM

Maintenance Bypass Yes, maintenance without interruptionEMI/EMC IEC/EN 62040-2:2006 C3

EMSIEC/EN 61000-4-2:2009 B (ESD) / IEC/EN 61000-4-3:2006 +A1:2008 +A2:2010 A (RS) IEC/EN 61000-4-4:2004+A1:2010 B(EFT) /

IEC/EN 61000-4-5:2006 B(Surge) IEC/EN 61000-4-6:2009 A(RF) / IEC/EN 61000-4-8:2010 A(Magnetic Field) IEC/EN 61000-4-11:2004 A(VD) / IEC/EN 61000-2-2:2002 A(LF)

-Line mode with batteryfull charged 92,0%-ECO mode 97,0%-Battery mode 91,0%Noise <48dB@<60%load,

<58dB@>60%load; 1m away<48dB@<60%load,

<60dB@>60%load;1m away <48dB@<60%load,<60dB@>60%load;1m awayOverload Capability (Line Mode)

110%: Transfer to bypass after 10 mins. 130%: Transfer to bypass after 1 min.150%: Transfer to bypass after 30s, shutdown after 1 min.(Line mode)

Overload Capability (Battery Mode)

<110%: Shutdown after 10mins>115%:Shutdown after 10s

Crest Ratio 3:1

BATTERY

Rating/Type Depend on the capacity of external batteries/Valve-regulated, non-spillable, lead acid

7AH Valve-regulated, non-spillable, lead acid

9AH Valve-regulated, non-spillable, lead acid

Quantity X V 1x16 x 12VBack-up Time Depend on the capacity of external batteries 4mins @80% load 3.5mins @80% loadBattery-Low Voltage (176±3)VDC-Charging voltage (220±1%)VDC-Charging current (max) 5A 1A-Charging time Depend on the capacity of external batteries 8 hours to 90% capacity after discharged into full load at nominal input

voltageLeakage current <2mA

INDICATOR &ALARM

Display LED+LCDAlarm Sounding once per secondFault Continuous beeping

INTERFACE

EPOSmart RS232 Standard Cable support EPC Power Monitor SoftwareUSB (option) Standard Cable support EPC Power Monitor SoftwareDry Contactor (option) DB9 type and phoenix terminal type for selectionSNMP(option) Power Managment from SNMP Manager and Web Browser

OPTION USB SNMP ECO Kit Dry Contactor Parallel Kit Battery Cabinet

MECHANICALWxHxD (mm) 438*130*680/438*130*706 max 438*218*680/438*130*754 maxNet Weight (kg) 18,5 21,5 62 70,5Color Black

ENVIRON-MENTAL

Operating Temperature 0-40º C ,no deratingStorage Temperature 0-70º CRelative Humidity 0-95% non-condensingOperating Elevation Up to 1000m (3281 ft) without derating

Notes1: Package Weight(KG) 20 23 76 84,5Notes2: *Products specifications are subject to change without further notice.NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Page 35: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr 35

HS SeriesLine Interactive UPS

GENERAL SPESIFICAITIONS

Automatic booting when the utility recovers

Wide range of input voltage

Alarm and mute

Auto recharging

Overvoltage and circuit short protection

Interface of RJ45/11 and USB

TECHNICAL SPECIFICATIONSMODEL HS 500Specifications 500VA/300W (no AVR)Display LED indicator (Black panel)

Input Voltage Range 110V: 92~135Vac, or220V:170~265Vac

Output Voltage Range 110V: 92~135Vac, or220V:170~265Vac

Output Frequency 110V: 60±0.5Hz (DC Mode), or220V: 50±0.5Hz (DC Mode)

Wave Form PWM DC Mode)Transfer Time ≤10msQTY & Capacity of Battery 1 pc*12V4.5Ah Charging Period 10~16 HOURSBackup Time 3~20 minutes 1PC+15 inch RCT)RJ45/11 & USB NoAuto Re-Starts When AC Recovers YesSilence Setup YesAutomatic Charging (Offline Charging) YesBattery Low Voltage Protection YesOverload & Short Circuit Protection YesUnit Dimension (mm) 250*95*140Color Box Dimension (mm) 290*140*205Master Box Dimension (mm) 305*298*430Pcs In One Master Carton 4Gross Weight (1pc, kg) 4,2Net Weight (1pc, kg) 4Loading Capacity (20' ctrn) 2520 pcsLoading Capacity (40' Gp) 5320 pcsWarranty Spare Parts 1% finished units or other spares equal to this valueMODEL HS 600 HS 1000 HS 1200 HS 1500Display LED or LCD, depends on user's choice.

Input Voltage Range 110V: 85~150Vac, or220V:145~290Vac

Output Voltage Range 110V: 102~132Vac, or220V:200~255Vac

Output Frequency (DC Mode) 110V: 60±0.5Hz / 220V:50±0.5HzWave Form PWM (DC Mode)Transfer Time ≤10msQty & Capacity Of Battery 1 pc*12V7Ah 2 pcs*12V7Ah 2 pcs*12V5Ah 2 pcs*12V9AhCharging Period 10~16 hours

Backup time 3~20 minutes 1PC+15 inch CRT 30~60 minutes 1PC+15 inch CRT 40~80 minutes 1PC+

15 inch CRTRJ45/11 & USB OptionalAuto Re-Starts When AC Recovers YesSilence Setup 9Automatic Charging (Offline Charging) YesBattery Low Voltage Protection YesOverload & Short Circuit Protection YesUnit Dimension (mm) 306 x 97 x 141 350 x 120 x 188Color Box Dimension (mm) 335 x 140 x 210 405 x 195 x 280Master Box Dimension (mm) 350 x 298 x 440 415 x 410 x 298Pcs In One Master Carton 4 2Gross Weight (1pc, kg) 4,60 10 10,8 12,6Net Weight (1pc, kg) 9,6 10,2 12Loading Capacity (20' ctrn) 2360 pcsLoading Capacity (40' Gp) 4920 pcsWarranty Spare Parts 1% finished units or other spares equal to this valueNOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Page 36: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr36

SLT200 Series Uninterruptible Power Supplies

GENERAL SPESIFICAITIONS True On-Line IGBT/IPM technology with sinusoidal output High reliability with microprocessor and intelligent

driver technology Advanced 2x16 LCD panel providing detailed information

(input/output voltage, battery voltage, charging current, interior temperature and setting user selectable parameters)

Led displays for easy status monitoring Advanced automatic and manual battery test system Increased power factor Overland, overheat & short circuit protections Remote Status monitoring and control via SNMP / HTTP / SMTP 200 Recorded event history RS232 and Dry contacts for communication and

remote monitoring Galvanic isolation transformer and special voltage

application options Language selection from LCD front panel (Turkish / English) Low total harmonic distortion (THD) level Manuel By-pass Cold Start Compact and quiet 2 years full warranty

OPTIONS Compatibility with major network management systems (NMS) Parallel redundant operation

TECHNICAL SPECIFICATIONSMODEL SLT 206 SLT 210 SLT 215 SLT 220Power 6 kVA / 4.2 kW 15 kVA / 10 kW 10.5 kVA / 15 kW 14 kVA / 20 kWINPuTVoltage 220 Vac 1 phase, NeutalVoltage Range ± 15%Frequency 50HzFrequency Range ± 5 %BATTERYNominal Voltage 243 Vdc 270 VdcFeed Time Dependent to requestType Maintenance free, dry typeCharge Time With nearly 10 hours, it reached to 90% capacity. (If the batteries are in a full discharga)OuTPuTVoltage 220 Vac 1 phase, NeutralVoltage Range ± 1%Frequency 50HzFrequency Range ± 0.1% (synchronous)Harmonic Distortion < 3% (for linear loads)Crest Factor 3:1

Over Laod Capacity 10 seconds for 125 % loadLinear according to over load quantity for 100% - 125% By-pass for loads over 125%

EFFICIENCYGeneral > 85 - 88 %Inverter > 90-92 %Transfer 0 msnAcoustic Noise < 55 dBA, 60 dBADISPLAYSDigital Displays “Input Voltage’ , “Battery Voltage” , “Output Voltage”

Led Displays “Output Frequency”, % Battery Fullnes Rate”, “% Yük”, “Alarms”, “Load isin by-pass”, Laod is in UPS”, “Alarm”, “Operating over batteris”

Alarms Laod is in UPS”, “Over load”, Mains Supply Fault”, Output Voltage is high/low”, “Over Temperature”, “Battery Voltage is high/low”, “Battery Fault”, “Short Circuit”

ALARMSOperating over batteries Audible arnings Periodically in Every 5 secondsUPS is broken down Continuous Audible warningCOMMuNICATIONRS232 Port Management and monitoringRelay Contact Mains Supply Fault, Battery low, System is in By-passSystems UNIX, LINUX, OS/2 NOWELL, WINDOWS NT, WINDOWS XPPERIPHERAL CONDITIONSTemperature 0 0C - 40 0CHumidity 0% - 95%DIMENSIONSDimensions (WxVxH) mm 275 x 810 x 825 325x810x825Weight (kg) 85 95 120 140STANDARDSSafety Standard EN50091-1, EMC, EN50091-2Quality Assurance ISO9001 CertifiedNOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Page 37: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr 37

GENERAL SPESIFICAITIONS True On-Line IGBT/IPM technology with sinusoidal output High reliability with microprocessor and intelligent

driver technology Advanced 2x16 LCD panel providing detailed information

(input/output voltage, battery voltage, charging current, interior temperature and setting user selectable parameters)

Led displays for easy status monitoring Advanced automatic and manual battery test system Increased power factor Overland, overheat & short circuit protections Remote Status monitoring and control via SNMP / HTTP / SMTP 200 Recorded event history RS232 and Dry contacts for communication and

remote monitoring Galvanic isolation transformer and special voltage

application options Language selection from LCD front panel (Turkish / English) Low total harmonic distortion (THD) level Manuel By-pass Cold Start Compact and quiet 2 years full warranty

OPTIONS Compatibility with major network management systems (NMS) Parallel redundant operation

SLT300 Series Uninterruptible Power Supplies

TECHNICAL SPECIFICATIONSMODEL SLT 310 SLT 315 SLT 320 SLT 330Power 10 kVA / 7 kW 15 kVA / 10,5 kW 20 kVA / 14 kW 30kVA / 21 kWINPuTVoltage 220 Vac 3 phase, NeutalVoltage Range ± 15%Frequency 50HzFrequency Range ± 5 %BATTERYNominal Voltage 354 VdcFeed Time Dependent to requestType Maintenance free, dry typeCharge Time With nearly 10 hours, it reached to 90% capacity. (If the batteries are in a full discharga)OuTPuTVoltage 220 Vac 1 phase, NeutralVoltage Range ± 1%Frequency 50HzFrequency Range ± 0.1% (synchronous)Harmonic Distortion < 3% (for linear loads)Crest Factor 3:1

Over Laod Capacity 10 seconds for 125 % loadLinear according to over load quantity for 100% - 125% By-pass for loads over 125%

EFFICIENCYGeneral > 85 - 88 %Inverter > 90-92 %Transfer 0 msnAcoustic Noise < 55 dBA, 60 dBADISPLAYSDigital Displays “Input Voltage’ , “Battery Voltage” , “Output Voltage”

Led Displays “Output Frequency”, % Battery Fullnes Rate”, “% Yük”, “Alarms”, “Load isin by-pass”, Laod is in UPS”, “Alarm”, “Operating over batteris”

Alarms Laod is in UPS”, “Over load”, Mains Supply Fault”, Output Voltage is high/low”, “Over Temperature”, “Battery Voltage is high/low”, “Battery Fault”, “Short Circuit”

ALARMSOperating over batteries Audible arnings Periodically in Every 5 secondsUPS is broken down Continuous Audible warningCOMMuNICATIONRS232 Port Management and monitoringRelay Contact Mains Supply Fault, Battery low, System is in By-passSystems UNIX, LINUX, OS/2 NOWELL, WINDOWS NT, WINDOWS XPPERIPHERAL CONDITIONSTemperature 0 0C - 40 0CHumidity 0% - 95%DIMENSIONSDimensions (WxVxH) mm 325x810x825Weight (kg) 110 130 140 160STANDARDSSafety Standard EN50091-1, EMC, EN50091-2Quality Assurance ISO9001 CertifiedNOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Page 38: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr38

Electronic DC LoadAutomatic Battery Discharger

GENERAL SPESIFICAITIONS This device is developed for charging with a stable current

the lead-acid, dry type and nickel cadmium batteries. Setted values are automatically calculated by a microcontroller

and displayed on an LCD screen. The calculated values are saved in memory unless they are deleted. The system does not effected by the electrical failures so the charging

process will automatically proceed. The voltage hysteresis are setted in production process and it chooses automatically the desired loads by means of the automatic voltage sense ability.

Discharge current and other functionels can be displayed and adjusted easily by the LCD display on the device.

Big advantages are supported to user with the neccecity safety precautions.

Battery discharge device works checking the battery voltage value. In case of the batteries are empty, disconnected to the system or connected to the system wrongly the device will alarm automatically visually and loudly.

This device is produced for lead-acid, dry-type and nickel-cadmium battery types.

The proper battery groups can be connected according to the desired discharge voltage.

Discharge current is setted according to the battery values. Discharge current can be calculated according to the battery capacity;

(C5 %20) (C10 %10) (C20 %5). For special applications various discharge values can be selected unless the safty conditions arent exceed.

To reduce the risk of electric shock, do not remove cover. Refer servicing to qualified service personnel. Disconnect the mains supply before connecting or disconnecting

the links to the battery.

TECHNICAL SPECIFICATIONSMODEL DC LoadInput Voltage 200 - 240V ACInput Current 2 A (5AFuse)Frequency 50 Hz / 60HzPower 300 VADischarge Rechargeable Battery Voltage 12V-24V-36V-48V-72V-80V-96V-110V-150 V DCDischarge Current 1A - 70A DC (1A)Over-Current Protection 100A DCThermal Heat Protection (Mosfet) 60 0CThermal Heat Protection (Rezistans) 80 0CCooling Continuous Cooling FanOperation Temperature -10 0C - 50 0CDegree of Protection IP 21Weight 30,3 kg ±300 grCable Weight 36 kg ±300 grThe battery capacity can be discharged 6 cell to 72 cell 10 Ah - 400 Ah(C5) -800 Ah(C10) -1600Ah (C20)NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Tech

nica

l fea

ture

of

Cabi

n;

Page 39: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr 39

VRLA SeriesBattery

The EnerSys® range of PowerSafe™ OPzS single cells has been designed for use in all standby power applications that demand the highest levels of reliability and security. PowerSafe OPzS cells benefit from an optimised plate design that results in increased capacity compared to the requirements of the internationally recognised DIN standard. In addition, the tubular plate technology offers excellent cycling performance together with a proven long life under float voltage conditions, for a truly flexible solution. The specification of the PowerSafe OPzS cells make it ideal for a wide range of applications such as telecommunications, telephony, power generation and distribution, railway, airport and seaport signalling, computing, emergency lighting, automation and measuring systems.

Features & Benefits Capacity range: 216Ah -

3360Ah (C10/1.80Vpc/20°C) C10 capacities exceed the

DIN standard values Excellent cyclability Long design life High operational reliability Low maintenance 3 year topping-up interval DIN 40736-1 compliant

TECHNICAL SPECIFICATIONS

Internal Type

Nom

inal

Vo

ltage

(V)

Num

ber

of

Term

inal

s

10hr

rat

e to

1.

80V

pc @

20

°C8h

r ra

te to

1.

75V

pc @

77

°F

Length width Height Over Vent Plug Dry Acid Filled Electrolyte

VolumeShort Circuit Current

(A)

Resis tance(mΩ)

mm in mm in mm in kg Ibs kg Ibs Litres us gal

4 OPzS 200 2 2 216 217 103 4.1 206 8.1 394 15.5 12.4 27.3 17.2 37.9 3.9 1.0 2400 0.855 OPzS 250 2 2 270 266 124 4.9 206 8.1 394 15.5 14.8 32.6 20.8 45.9 4.9 1.3 3000 0.686 OPzS 300 2 2 324 319 145 5.7 206 8.1 394 15.5 17.1 37.7 24.3 53.6 5.8 1.5 3600 0.575 OPzS 350 2 2 390 388 124 4.9 206 8.1 510 20.1 19.0 41.9 26.9 59.3 6.7 1.8 3400 0.606 OPzS 420 2 2 468 466 145 5.7 206 8.1 510 20.1 22.1 48.7 31.5 69.4 8.0 2.1 4075 0.507 OPzS 490 2 2 546 543 166 6.5 206 8.1 510 20.1 25.2 55.6 36.1 79.6 9.3 2.5 4750 0.436 OPzS 600 2 2 660 648 145 5.7 206 8.1 685 27.0 31.9 70.3 44.8 98.8 11.1 2.9 5000 0.407 OPzS 700 2 4 817 798 210 8.3 191 7.5 685 27.0 40.4 89.1 57.6 127.0 14.8 3.9 5800 0.348 OPzS 800 2 4 880 856 210 8.3 191 7.5 685 27.0 44.4 97.9 61.3 135.1 14.5 3.8 6650 0.309 OPzS 900 2 4 1040 1013 210 8.3 233 9.2 685 27.0 49.6 109.3 70.9 156.3 18.4 4.9 7475 0.2710 OPzS 1000 2 4 1100 1071 210 8.3 233 9.2 685 27.0 53.5 118.0 74.6 164.5 18.1 4.8 8300 0.2411 OPzS 1100 2 4 1260 1227 210 8.3 275 10.8 685 27.0 58.9 129.9 84.4 186.0 20.8 5.5 9150 0.2212 OPzS 1200 2 4 1320 1293 210 8.3 275 10.8 685 27.0 62.8 138.4 88.0 194.0 20.6 5.4 9950 0.2011 OPzS 1375 2 4 1590 1631 210 8.3 275 10.8 835 32.9 74.5 164.2 109 240.3 27.6 7.3 8800 0.2212 OPzS 1500 2 4 1680 1730 210 8.3 275 10.8 835 32.9 80.2 176.8 114.3 252.0 27.3 7.2 9600 0.2113 OPzS 1625 2 6 1910 1969 214 8.4 399 15.7 811 32.0 91.2 201.1 140 308.7 39.6 10.5 10400 0.1914 OPzS 1750 2 6 2040 2092 214 8.4 399 15.7 811 32.0 95.8 211.2 144 317.5 39.6 10.5 11200 0.1815 OPzS 1875 2 6 2150 2208 214 8.4 399 15.7 811 32.0 101 222.7 149 328.5 38.9 10.3 12000 0.1616 OPzS 2000 2 6 2240 2307 214 8.4 399 15.7 811 32.0 105 231.5 151.5 334.0 39.0 10.3 12800 0.1517 OPzS 2125 2 8 2470 2546 212 8.3 487 19.2 811 32.0 119 262.3 180 396.9 48.5 12.8 13600 0.1418 OPzS 2250 2 8 2600 2669 212 8.3 487 19.2 811 32.0 125 275.6 184 405.7 47.8 12.6 14400 0.1419 OPzS 2375 2 8 2710 2785 212 8.3 487 19.2 811 32.0 130 286.6 189 416.7 47.5 12.5 15200 0.1320 OPzS 2500 2 8 2800 2884 212 8.3 487 19.2 811 32.0 134 295.4 193 425.5 47.6 12.6 16000 0.1222 OPzS 2750 2 8 3150 3238 212 8.3 576 22.7 811 32.0 153 337.3 225 496.0 57.8 15.3 17600 0.1124 OPzS 3000 2 8 3360 3543 212 8.3 576 22.7 811 32.0 163 359.4 234.5 517.0 56.4 14.9 19200 0.10NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Page 40: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr40

Kokam SeriesBattery

Lithium poliymer and lithium ion batteries

Insured Safety of Kokam’s SLPB

Kokam’s Superior Lithium Polymer

Batteries have an excellent safety

performance which originates in our

unique technology.

Kokam Battery Pack Solution

Throughout the years, Kokam has

developed and refined its own line of

technology that has made way for the

successful production of the most effective

battery product for battery packs.

No ModelCapacity

(Ah)1 SLPB110255255H 602 SLPB96255255 603 SLPB60460330H 704 SLPB53460330 705 SLPB110255255 706 SLPB120255255 757 SLPB125255255H 758 SLPB70460330H 809 SLPB125255255 8710 SLPB80460330H 10011 SLPB70460330 10012 SLPB120460330 15013 SLPB160460330H 20014 SLPB140460330 20015 SLPB160460330 240

Cell SpecificationSLP-

B100255255HR2Value Remarks

Capacity (Ah) 55 @ 0.5CIR (mOhm) 0.5 @ 1kHz

Voltage 3.0 V ~ 4.2 VWeight (kg) 1.36

Cycle Life @ 100% DOD Over 4,500 cycles

Max Continouns Charge Current 147 A

Max Continouns Discharge Current 284 A

UL Certification Certified

Dimen-sion (mm)

Thickness 9.4Width 255

Length 255

Page 41: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr 41

Ni-Cd Alcad SeriesBattery

Page 42: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr42

Integrated Solutions

GENERAL SPESIFICAITIONS

These systems are produced in variety options. For example; parallelly

working rectifiers, inverters, STS and battery group mounted in same cabin.

SMPS, Hi-rect and rectifier systems which includes the battery group.

Parallelly working rectifiers with battery group.

Parallelly working inverters, rectifiers and static by-pass systems with battery working.

Systems which has Battery group, rectifiers, inverters and distribution fuses.

Useable Areas

Airports

Energy distribution systems

Telecommunication systems

Oil production platforms

Gas distribution stati ons

Production Range

According to the customer reguirement

Page 43: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr 43

Solar Systems

GENERAL SPESIFICAITIONS FieldSurveys Powerproductionpotentialsimulations Fieldlayoutdrawings Equipmentselectionandsupply SingleLineDiagram Mechanicalprojects Fieldsupervision Consultance Commissioning, start up and maintenance Fast delivery from stock, ‘Solar panel, On grid/ Off grid inverter,

Battery, Solar charger, power kits, led lighting, Wind Generator, Construction material etc.’

Solar panel, On grid/ Off grid inverter, Battery, Solar charger, power kits, led lighting, Wind Generator, Construction material etc.

No need to replace your existing AC motor. Converts solar power into mechanical power with very high efficieny Fastandeasyinstallation Almost no maintenance, quiet and clean Grid power or costly combustion motors are not needed Low carbon foot print PV Panel, inverter, battery Off grid battery back up The batteries can be charged via grid & generator The batteries can be charged via built in solar charger Enhanced LCD display shows all essential data Puresinusoutput Residential, Telecommunication and Military applications.

Page 44: EPC ENERGY AND POWER CONVERSION SYSTEMSdonar.messe.de/exhibitor/hannovermesse/2017/E352117/epc-english... · 1 EPC ENERGY AND POWER CONVERSION SYSTEMS ... 2 ... COMMuNICATION & PARALLELING

www.epcas.com.tr44

İSTANBUL ANATOLIANAdres: Esensehir Mah. Kıraçlar Sok. No:11/ 2-3 Madenler, Yukarı Dudullu Ümraniye / İstanbulTel: +90 216 499 54 84

Metin TEK Tel: +90 532 307 33 48Tuncay OKUR Tel: +90 549 851 07 81Email: [email protected] Web: www.epcas.com.tr

ADANA REGIONDEMİRALP ELEKTRİK ELEKTRONİK SAN. TİC. LTD. ŞTİ.ÜNAL DEMİRALPAHMET ZENGİNTel: +90 322 248 71 22Adres: Toros Mah. 78195 Sk. Yeter Bey Apartmanı Zemin Kat 4/A Seyhan / Adana ANKARA REGION-1TT GÜÇ SİSTEMLERİ ELEKTRİK VE ELEKTRONİK SAN. TİC. LTD. ŞTİ.TURGUT YILMAZTUNCAY YILMAZGsm: +90 532 354 45 98Adres: İlkadım Mah. Sinan Cad. Etkin Sok. No:8/14 Dikmen / Ankara ANKARA REGION-2EKATEKNİK GÜÇ ELEKTRONİK SİS. SAN. TİC. LTD. ŞTİCEM SAYANTel: +90 312 342 00 99 Gsm: +90 505 339 10 70Adres: Büyük Sanayi 1.Cad. Elif Sk. No: 7/79 İskitler / Ankara ANTALYA REGIONEKC ENERJİ VE KONTROL CİHAZLARIALİ DEMİRTel: +90 242 247 93 91Adres: Kızılsaray Mah. Yener Ulusoy Bulvarı 73. Sk. No:4/A Muratpaşa / Antalya BURSA REGION-1ENERSER ENERJİ ELEKTRİK ELEKTRONİK LTD. ŞTİ.NURDOĞAN BEYTel: +90 224 441 24 41Adres: Nilüfer Tic. Merkezi 637.Sk. No:27 Aksa Jeneratör Arkası Nilüfer / Bursa ERZURUM REGION-1ELECTROFFICE BİL. VE ELEKTRONİK TEKNİK SERVİS HİZ.MURAT ADIGÜZELTel: +90 442 235 14 70Adres: Aşağı Mumcu Cad. Erzurum İş Merkezi Kat:3 No:81 Erzurum

GAZİANTEP REGION-1SÖZMEN ELEKTRİK ELEK. MAL. TAAHHUT SAN. TİC. LTD. ŞTİ.NEJAT DENİZTel: +90 342 323 68 09Adres: İncilipınar Mah. Kibris Cad. No:18/CŞehitkamil / Gaziantep İSTANBUL EUROPEANERK ENERJİ MÜHENDİSLİK VE SERVİS HİZ. LTD. ŞTİ.ERDOĞAN KARAAHMETOĞLUTel: +90 212 269 36 89Gsm: +90 539 553 81 30Adres: Sanayi̇ Mah. Sultan Selim Cad. Gökyüzü Sok. No:3 4.Levent / İstanbul İZMİR REGION-14A ELEKTRONİKAYHAN ŞENADATel: +90 236 231 94 11Adres: Şehitler Mah. Şehitler Cad. 17/A-6 Şehzadeler / Manisa İZMİR REGION-2EKS GÜÇ ELEKTRONİK KONTROL ALETLERİ SAN. TİC. LTD. ŞTİ.BÜLENT ARTel: +90 232 446 25 56Adres: 1412 Sok. No:68 A Kahramanlar / İzmir SAMSUN REGION-1KARAT ELEKTRONİKBÜLENT MAVİTel: +90 362 231 10 57Adres: İstasyon Mah. Yunus Emre Sk. No: 3/C Samsun

Dealer & Service