ENVIRONMENTAL MONITORING REPORT - indobaijin...Plot No. Z-7/1, SEZ Area, Dahej SEZ Ltd, Ta –...
Transcript of ENVIRONMENTAL MONITORING REPORT - indobaijin...Plot No. Z-7/1, SEZ Area, Dahej SEZ Ltd, Ta –...
ENVIRONMENTAL MONITORING
REPORT
FOR
M/s. Indobaijin Chemicals Pvt.Ltd.
Monitoring Organization
Period: – January - 2017
At Plot No.Z /7/1,SEZ Area
Dahej SEZ Ltd, Ta.: Vagra Dist.: Bharuch – 392130, Gujarat. India.
INDEX NO. CONTENTS
Page
no.
Environment Component 1
1.0 Ambient Air Quality Monitoring Report 2
Results of Location : AAQM-1 (Near Main Gate) 3
Results of Location : AAQM-2 (Near RRU Plant) 4
Results of Location : AAQM-3 (Near MSPU Plant) 5
2.0 Stack Monitoring Report 6
Result of Location : DG Set 7
Result of Location : DG Set 8
Result of Location : Process Stack 9
3.0 Water Quality Monitoring Report 10
Result of Location : Treated Sewage Water 11
4.0 Noise Level Monitoring Report 13
Result of Location : NM- 1 (Near Main Gate) 14
Result of Location : NM- 2 (Near CS2 Loading Point)
Result of Location : NM- 3 (Near Utility Compressor area)
Result of Location : NM- 4 (Near Utility DM Plant area)
Result of Location : NM- 5 (Near C.T fire Pump Room & Turbine)
Result of Location : NM- 6 (Near RRU H₂S Compressor)
Result of Location : NM- 7 (Near RRU Ground Floor)
Result of Location : NM- 8 (Near SRU Furnace)
Result of Location : NM- 9 (Near MSPU Ground Floor)
Result of Location : NM- 10 (Near Sulphar Conveyer Area)
5.0 Soil Monitoring Report 15
Result of Location : Near Tank Farm 16
6.0 Work Place Monitoring Report 17
Result of Location : Near SRU Unit –Incinerator 18
Environmental Monitoring Plan For M/s. Indobaijin Chemicals Pvt.Ltd.
By – UniStar Environment and Research Labs Pvt. Ltd.
1
Sr. No.
Environmental Component
Parameters Location Frequency
Total No. of
Samples in Dec-16
Monitoring carried out in Dce-16
1.
Ambient Air
Quality
Monitoring
PM10, PM2.5, Sox, H2S, CS2 03 Monthly 03 03
2. Stack Monitoring PM, SO2, NOx, NMC (Non-
Methyl Hydrocarbon contain), H2S, CS2
03 Monthly 03 03
3. Treated Sewage
Water Sampling BOD, Suspended Solids,
Residual Chlorine 01 Monthly 01 01
4. Soil Sampling
pH( 5% Solution),Acidity,
COD,BOD, Chloride,Oil &
Grease Sulphate ,Copper as
Cu, Iron as Fe Lead as Pb
,Zinc as Zn, Moisture
Content
01 Quarterly 01 01
5. Drinking Water
Quality Sampling As Per IS:10500 01
Half
yearly -- --
6. Noise Level
Monitoring dB(A) Day & Night 09 Monthly 09 09
1.0 AMBIENT AIR QUALITY MONITORING REPORT
FOR
M/s. Indobaijin Chemicals Pvt.Ltd.
Plot No. /7/1, SEZ Area Dahej SEZ Ltd, Ta.: Vagra
Dist.: Bharuch – 392130, Gujarat. India.
Monitoring Organization
Period: – January - 2017
TEST REPORT
(AMBIENT AIR MONITORING)
Test Report No.: UERL/17/01/A-001 Report Issue Date 01/02/2017
Service Request form No.: UERL/AIR/SRF/01/001 Service Request Date 16/01/2017
Sample ID No.: UERL/AIR/ID/A-17/01/001 Field Data Sheet No. UERL/AIR/FDS/A-17/01/001
Name & Add. of Customer M/s. Indo Baijin Chemicals Pvt Ltd.
Plot No. Z-7/1, SEZ Area,
Dahej SEZ Ltd,
Ta – Vagra, Dist.-Bharuch
Gujarat, Pin Code – 392130
Dates of Sampling : 16/01/2017 Date of Testing 17/01/2017
Location of Sampling / Monitoring: Near Main Gate
Details of Master Instrument Used for Monitoring
Instrument Id No. Instrument Name Serial Number Cali. Date Next Cali. Date
UERL/AIR/RDS/03 Respirable Dust Sampler RDS:SR.No.160203106 17/08/2016 16/08/2017
UERL/AIR/FPS/06 Fine Particulate Sampler FPS:SR.No.1608020270 17/08/2016 16/08/2017
General Sampling / Monitoring Observation as per CPCB Guideline
Sr. No.
Description Unit of measurement Observation
1. Monitoring Duration h 24
2. Flow Rate of PM10 m3/min 1.30
3. Volume of Air Sampled for PM10 m3 1872
4. Volume of Air Sampled for PM2.5 m3 24.32
5. Flow Rate for Gas L/min 1.5
6. Volume of Air Sample for Gas L 2160
Test Parameter Results
Sr. No.
Test Parameter Unit Result Specific Value (As per NAAQMS)
1. Particulate Matter PM2.5 µg/m3 22 60
2. Particulate Matter PM10 µg/m3 78 100
3. Sulphur Dioxide µg/m3 28 80
4. Nitrogen Dioxide µg/m3 38 80
5. Hydrogen Sulphide(H₂S) µg/m3 Not Detected 500
6. Carbon disulphide (CS₂) µg/m3 Not Detected 2000
Sampling Done by:
Tested by:
Authorized by:
(Chemist)
(Chemist) / (Sr. Chemist) (Sr. Chemist)
Page No.: 3 UERL/AIR/F-04/00
TEST REPORT
(AMBIENT AIR MONITORING)
Test Report No.: UERL/17/01/A-002 Report Issue Date 01/02/2017
Service Request form No.: UERL/AIR/SRF/01/002 Service Request Date 16/01/2017
Sample ID No.: UERL/AIR/ID/A-17/01/002 Field Data Sheet No. UERL/AIR/FDS/A-17/01/002
Name & Add. of Customer M/s. Indo Baijin Chemicals Pvt Ltd.
Plot No. Z-7/1, SEZ Area,
Dahej SEZ Ltd,
Ta – Vagra, Dist.-Bharuch
Gujarat, Pin Code – 392130
Dates of Sampling : 16/01/2017 Date of Testing 17/01/2017
Location of Sampling / Monitoring: Near RRU Plant
Details of Master Instrument Used for Monitoring
Instrument Id No. Instrument Name Serial Number Cali. Date Next Cali. Date
UERL/AIR/RDS/03 Respirable Dust Sampler RDS:SR.No.160203118 17/08/2016 16/08/2017
UERL/AIR/FPS/06 Fine Particulate Sampler FPS:SR.No.160802033 17/08/2016 16/08/2017
General Sampling / Monitoring Observation as per CPCB Guideline
Sr. No.
Description Unit of measurement Observation
1. Monitoring Duration h 24
2. Flow Rate of PM10 m3/min 1.32
3. Volume of Air Sampled for PM10 m3 1900.8
4. Volume of Air Sampled for PM2.5 m3 24.31
5. Flow Rate for Gas L/min 1.5
6. Volume of Air Sample for Gas L 2160
Test Parameter Results
Sr. No.
Test Parameter Unit Result Specific Value (As per NAAQMS)
1. Particulate Matter PM2.5 µg/m3 26 60
2. Particulate Matter PM10 µg/m3 72 100
3. Sulphur Dioxide µg/m3 32 80
4. Nitrogen Dioxide µg/m3 42 80
5. Hydrogen Sulphide(H₂S) µg/m3 Not Detected 500
6. Carbon disulphide (CS₂) µg/m3 Not Detected 2000
Sampling Done by:
Tested by:
Authorized by:
(Chemist)
(Chemist) / (Sr. Chemist) (Sr. Chemist)
Page No.: 4 UERL/AIR/F-04/00
TEST REPORT
(AMBIENT AIR MONITORING)
Test Report No.: UERL/17/01/A-003 Report Issue Date 01/02/2017
Service Request form No.: UERL/AIR/SRF/01/003 Service Request Date 17/01/2017
Sample ID No.: UERL/AIR/ID/A-17/01/003 Field Data Sheet No. UERL/AIR/FDS/A-17/01/003
Name & Add. of Customer M/s. Indo Baijin Chemicals Pvt Ltd.
Plot No. Z-7/1, SEZ Area,
Dahej SEZ Ltd,
Ta – Vagra, Dist.-Bharuch
Gujarat, Pin Code – 392130
Dates of Sampling : 16/01/2017 Date of Testing 17/01/2017
Location of Sampling / Monitoring: Near MSPU Plant
Details of Master Instrument Used for Monitoring
Instrument Id No. Instrument Name Serial Number Cali. Date Next Cali. Date
UERL/AIR/RDS/03 Respirable Dust Sampler 1716-DTE-2010, 287-DTD-2010
25/10/2016 24/10/2017
UERL/AIR/FPS/06 Fine Particulate Sampler 195 – DTK – 2013 15/11/2016 14/11/2017
General Sampling / Monitoring Observation as per CPCB Guideline
Sr. No.
Description Unit of measurement Observation
7. Monitoring Duration h 24
8. Flow Rate of PM10 m3/min 1.31
9. Volume of Air Sampled for PM10 m3 1886.4
10. Volume of Air Sampled for PM2.5 m3 24.18
11. Flow Rate for Gas L/min 1.5
12. Volume of Air Sample for Gas L 2160
Test Parameter Results
Sr. No.
Test Parameter Unit Result Specific Value (As per NAAQMS)
7. Particulate Matter PM2.5 µg/m3 21 60
8. Particulate Matter PM10 µg/m3 82 100
9. Sulphur Dioxide µg/m3 28 80
10. Nitrogen Dioxide µg/m3 40 80
11. Hydrogen Sulphide(H₂S) µg/m3 Not Detected 500
12. Carbon disulphide (CS₂) µg/m3 Not Detected 2000
Sampling Done By:
Tested By:
Authorized By:
(Chemist)
(Chemist) / (Sr. Chemist) (Sr. Chemist)
Page No.: 5 UERL/AIR/F-04/00
2.0 STACK MONITORING REPORT
FOR
M/s. Indobaijin Chemicals Pvt.Ltd.
Plot No.Z /7/1,SEZ Area Dahej SEZ Ltd, Ta.: Vagra
Dist.: Bharuch – 392130, Gujarat. India.
Monitoring Organization
Period: –January- 2017
TEST REPORT
(STACK MONITORING)
Details of Instrument Used for Monitoring
Instrument Id No. UERL/AIR/SMK/52
Instrument Name Stack Monitoring Kit, VSS1 Serial Number 467 DTJ 15
Calibration Date 30/12/2016 Next Calibration Due On 29/12/2017
General Stack Monitoring Observation
Sr. No.
Description Unit of
measurement Observation
1. Stack Height m 11
2. Stack Dia mm 203
3. Stack Area m2 0.0323
4. Ambient Temperature oC 30
5. Flue Gas Temperature oC 264
6. Exit Gas Velocity m/s 21.55
7. Exit Gas Flow m3/h 2505.83
Test Parameter Results
Sr. No.
Test Parameter Unit of
measurement Result
Specific Value
Test Method
1. Particulate Matter mg/Nm3 82 150 IS 11255(Part 1)
2. Sulphur Dioxide ppm 36 100 IS 11255(Part 2)
3. Oxide of Nitrogen ppm 42 50 IS 11255(Part 7)
4. Hydro Carbon (as HC) gm/kw-hr 2.1 ≤4.0 By flue gas analyzer
Sampling Done by:
Tested by:
Authorized by:
(Chemist)
(Chemist) / (Sr. Chemist) (Sr. Chemist)
Page No.: 7
UERL/AIR/F-04/00
Test Report No. UERL/17/01/S-001 Report Issue Date 01/02/2017
Service Request form No. UERL/AIR/SRF/01/001 Service Request Date 17/01/2017
Sample ID No. UERL/AIR/ID/S-17/01/001 Field Data Sheet No. UERL/AIR/FDS/S-17/01/001
Name & Add. of Customer
M/s.Indo Baijin Chemicals Pvt Ltd. Plot No. Z-7/1, SEZ Area,Dahej SEZ Ltd,
Ta – Vagra, Dist.-Bharuch
Gujarat, Pin Code – 392130
Date of Sampling 17/01/2017 Date of Testing 18/01/2017
Stack Sampling Attached to D. G. Set 1000 KVA
Air Pollution Control Device --
Fuel Used Diesel
TEST REPORT
(STACK MONITORING)
Details of Instrument Used for Monitoring
Instrument Id No. UERL/AIR/SMK/52
Instrument Name Stack Monitoring Kit, VSS1 Serial Number 467 DTJ 15
Calibration Date 30/12/2016 Next Calibration Due On 29/12/2017
General Stack Monitoring Observation
Sr. No.
Description Unit of
measurement Observation
1. Stack Height m 11
2. Stack Dia mm 203
3. Stack Area m2 0.0323
4. Ambient Temperature oC 30
5. Flue Gas Temperature oC 275
6. Exit Gas Velocity m/s 22.24
7. Exit Gas Flow m3/h 2586.07
Test Parameter Results
Sr. No.
Test Parameter Unit of
measurement Result
Specific Value
Test Method
1. Particulate Matter mg/Nm3 76 150 IS 11255(Part 1)
2. Sulphur Dioxide ppm 30 100 IS 11255(Part 2)
3. Oxide of Nitrogen ppm 46 50 IS 11255(Part 7)
4. Hydro Carbon (as HC) gm/kw-hr 1.9 ≤4.0 By flue gas analyzer
Test Report No. UERL/17/01/S-002 Report Issue Date 01/02/2017
Service Request form No. UERL/AIR/SRF/01/002 Service Request Date 17/01/2017
Sample ID No. UERL/AIR/ID/S-17/01/002 Field Data Sheet No. UERL/AIR/FDS/S-17/01/002
Name & Add. of Customer
M/s.Indo Baijin Chemicals Pvt Ltd. Plot No. Z-7/1, SEZ Area, Dahej SEZ Ltd,
Ta – Vagra, Dist.-Bharuch
Gujarat, Pin Code – 392130
Date of Sampling 17/01/2017 Date of Testing 18/01/2017
Stack Sampling Attached to D. G. Set 1000 KVA
Air Pollution Control Device --
Fuel Used Diesel
Sampling Done by:
Tested by:
Authorized by:
(Chemist)
(Chemist) / (Sr. Chemist) (Sr. Chemist)
Page No.: 8 UERL/AIR/F-04/00
TEST REPORT
(STACK MONITORING)
Details of Instrument Used for Monitoring
Instrument Id No. UERL/AIR/SMK/52
Instrument Name Stack Monitoring Kit, VSS1 Serial Number 467 DTJ 15
Calibration Date 30/12/2016 Next Calibration Due On 29/12/2017
General Stack Monitoring Observation
Sr. No.
Description Unit of
measurement Observation
1. Stack Height m 80
2. Stack Dia mm 1600
3. Stack Area m2 2.0096
4. Ambient Temperature oC 30
5. Flue Gas Temperature oC 92
6. Exit Gas Velocity m/s 4.82
7. Exit Gas Flow m3/h 34870.57
Test Parameter Results
Sr. No.
Test Parameter Unit of
measurement Result
Specific Value
Test Method
1. Particulate Matter mg/Nm3 N.D 150 IS 11255(Part 1)
2. Sulphur Dioxide ppm 36 100 IS 11255(Part 2)
3. Oxide of Nitrogen ppm 24 50 IS 11255(Part 7)
4. Hydro Carbon (as HC) gm/kw-hr N.D ≤4.0 By flue gas analyzer
Test Report No. UERL/17/01/S-003 Report Issue Date 01/02/2017
Service Request form No. UERL/AIR/SRF/01/003 Service Request Date 17/01/2017
Sample ID No. UERL/AIR/ID/S-17/01/003 Field Data Sheet No. UERL/AIR/FDS/S-17/01/003
Name & Add. of Customer
M/s.Indo Baijin Chemicals Pvt Ltd. Plot No. Z-7/1, SEZ Area, Dahej SEZ Ltd,
Ta – Vagra, Dist.-Bharuch
Gujarat, Pin Code – 392130
Date of Sampling 17/01/2017 Date of Testing 18/01/2017
Stack Sampling Attached to Process Gas Emission
Air Pollution Control Device --
Fuel Used --
Sampling Done by:
Tested by:
Authorized by:
(Chemist)
Page No.:9
(Chemist) / (Sr. Chemist) (Sr. Chemist)
3.0 WATER QUALITY MONITORING REPORT
FOR
M/s. Indobaijin Chemicals Pvt.Ltd.
Plot No.Z /7/1,SEZ Area Dahej SEZ Ltd, Ta.: Vagra
Dist.: Bharuch – 392130, Gujarat. India.
Monitoring Organization
Period: – January - 2017
TEST REPORT
Report No. UERL /17/01/L-0371 Date Of Report 25/01/2017
Name & Address of Customer M/s. Indo Baijin Chemicals Pvt. Ltd.
Plot No. Z/7/1, SEZ Area, Dahej SEZ Ltd.
Tal - Vagra, Dist - Bharuch - 392130, Gujarat
Sample Details STP Treated Water Sample Qty. 2 Lit.
Sampling Date 18/01/2017 Sample Received Date 18/01/2017
Sampled By Us. Appearance Of Sample Light yellow
Test Started Date 19/01/2017 Test Completion Date 24/01/2017
UERL Lab Sample ID.No. 17/01/L-0371
TEST RESULTS Sr. No.
Parameters Test Method GPCB Limit Results
CHEMICAL QUALITY (In mg/L)
1. Total Suspended Solids IS 3025(Part 17)1984,Amd.1
(APHA 22ndEd.,2012,2540 –D), <30 22
2. Biochemical Oxygen Demand (BOD)
( 5 days at 20 0C) IS 3025(Part44)1993, Amd. 1 <20 17
3. Residual Free Chlorine IS 3025(Part 26)1986,
APHA 22ndEd.,2012,4500-Cl-B 0.5 Min. 1.76
******* End of Report *******
Tested By Checked By Authorized By
(Chemist) (Sr. Chemist) (Technical Manager)
Page No.11 UERL/CHM/F–2/02
4.0 NOISE LEVEL MONITORING REPORT
FOR
M/s. Indobaijin Chemicals Pvt.Ltd.
Plot No.Z /7/1,SEZ Area Dahej SEZ Ltd, Ta.: Vagra
Dist.: Bharuch – 392130, Gujarat. India.
Monitoring Organization
Period: –January- 2017
NOISE LEVEL MONITORING REPORT
Test Report No.: 17/01/N-IB001 Date Of Report: 01/02/2017
Name & Add. Of Industries
M/s. Indo Baijin Chemicals Pvt Ltd. Plot No. Z-7/1, SEZ Area, Dahej SEZ Ltd,
Ta – Vagra, Dist.-Bharuch
Gujarat, Pin Code – 392130
Details of Instrument Used for Monitoring.
Instrument Id No. Instrument Name Model Number Cali. Date Next Cali. Date
UERL/AIR/SLM/09A Sound Level Meter 309-DTK-2015 01/11/2016 31/10/2017
Date of Monitoring : 17-01-2017
Results:
Note:
Checked By:
Authorized By:
Page No.:14
Sr. No.
Location
Noise Level dB(A)
Day Time Night Time
Permissible Limit CPCB
Day Time Night Time
1. Near Main Gate 58.2 44.1 75 dB (A) 70 dB (A)
2. Near CS2 Loading Point 73.1 56.1 75 dB (A) 70 dB (A)
3. Near Utility Compressor area 74.6 52.1 75 dB (A) 70 dB (A)
4. Near Utility DM Plant area 62.7 53.1 75 dB (A) 70 dB (A)
5. Near C.T fire Pump Room & Turbine 62.1 52.1 75 dB (A) 70 dB (A)
6. Near RRU H₂S Compressor 62.1 51.2 75 dB (A) 70 dB (A)
7. Near RRU Ground Floor 62.8 52.1 75 dB (A) 70 dB (A)
8. Near SRU Furnace 66.2 52.3 75 dB (A) 70 dB (A)
9. Near MSPU Ground Floor 68.2 52.1 75 dB (A) 70 dB (A)
10. Near Sulphar Conveyer Area 62.8 48.2 75 dB (A) 70 dB (A)
5.0 SOIL QUALITY MONITORING REPORT
FOR
M/s. Indobaijin Chemicals Pvt.Ltd.
Plot No.Z /7/1,SEZ Area Dahej SEZ Ltd, Ta.: Vagra
Dist.: Bharuch – 392130, Gujarat. India.
Monitoring Organization
Period: –January- 2017
TEST REPORT
Report No. UERL /17/01/L-0372 Date Of Report 25/01/2017
Name & Address of Customer M/s. Indo Baijin Chemicals Pvt. Ltd.
Plot No. Z/7/1, SEZ Area, Dahej SEZ Ltd.
Tal - Vagra, Dist - Bharuch - 392130, Gujarat
Sample Details Soil Sample (Near Tank Farm ) Sample Qty. 1 kg.
Sampling Date 18/01/2017 Sample Received Date 18/01/2017
Sampled By Us. Appearance Of Sample Brown Colour
Test Started Date 19/01/2017 Test Completion Date 23/01/2017
UERL Lab Sample ID.No. 16/11/L-0212
TEST RESULTS
Sr.
No. Parameters Unit Of Measurement Results
1. pH( 5% Solution) -- 8.85
2. Acidity mg/kg N.D.
3. COD mg/kg 14016.1
4. BOD mg/kg 4770
5. Chloride mg/kg 122.8
6. Oil & Grease mg/kg 14.0
7. Sulphate mg/kg 384
8. Copper as Cu mg/kg 0.415
9. Iron as Fe mg/kg 220.1
10. Lead as Pb mg/kg 0.145
11. Zinc as Zn mg/kg 0.492
12. Moisture Content %% 2.96
Note: N.D. = Not Detected, Reference: R.K. Chaturvedi & M.L. Jackson
Checked By Tested By Approved By
(Chemist) (Sr. Chemist) (Technical Manager)
Page No.16 UERL/CHM/F–2/02
UNISTAR ENVIRONMENT & RESEARCH LABS PVT. LTD.
Prepared By: Approved By
Manager - Operations Technical Manager
Page 1 of 1 UERL/AIR/F-73/00
Calibration Certificate
Instrument Name : Respirable Dust Sampler
Instrument ID No. : UERL/AIR/RDS/13
Instrument Sr. No. Supplier : 1716-DTE-2010, 287-DTD-2010
Calibration Certificate No. : UERL/CC/RDS-07/1101/15-16
Date of Calibration : 25/10/2016
Next Calibration due Date : 24/10/2017
Sr.
No.
Name of Unit Calibrated and
Certificate No.
Calibrator Traceable to Calibration Certificate
No. Date of Calibration
1. Flow Meter
ID. No.
(UERL/AIR/RDS/FM/13)
Top Loading Orifice
Ecotech Instruments (Greater Noida)
Id No.:
(UERL/MASTER/AIR/AA/MM/01)
Pressure Indicator
Ecotech Instruments (Greater Noida)
EI – CCS/FF/TLC/67
Date of Cali.: 18.08.2015
EI – CCS/MECH/PI/539
Date of Cali.: 22.09.2016
2. Time Totalizer
ID. No.
(UERL/AIR/RDS/TT/13)
Ecotech Instruments (Greater Noida)
ID. No.
(UERL/MASTER/AIR/TT/aa/01)
EI – CCS/ET/TT/2446
Date of Cali.: 22.09.2016
3. Rotameter
ID. No.
(UERL/AIR/RDS/RM/13)
Rotameter
Ecotech Instruments (Greater Noida)
IDNo.
(UERL/MASTER/AIR/RM/02)
EI – CCS/FF/RF/2905
Date of Cali.: 22.09.2016
UNCERTAINTY MEASUREMENT: Flow Meter : ± 0.061 m3/min.
UNCERTAINTY MEASUREMENT: Time Totalizer : ± 0.031 hour
UNCERTAINTY MEASUREMENT: Rotameter : ± 0.160 LPM
The reported uncertainty is the expanded uncertainty in measurement at 95 % Confidence level with coverage fact
or k = 2 which corresponds to coverage probability of approximately 95 % of normal distribution.
UNISTAR ENVIRONMENT & RESEARCH LABS PVT. LTD.
Prepared By: Approved By
Manager-Operations Technical Manager
Page 1 of 1 UERL/AIR/F-73/00
Calibration Certificate
Instrument Name : Fine Particulate Sampler
Instrument ID No. : UERL/AIR/FPS/49
Instrument Sr. No. Supplier : 195 – DTK – 2013
Calibration Certificate No. : UERL/CC/FPS-18/1115/15-16
Date of Calibration : 15/11/2016
Next Calibration due Date : 14/11/2017
Sr.
No.
Name of Unit Calibrated and
Certificate No.
Calibrator Traceable to Calibration Certificate
No. Date of Calibration
1. Rotameter
ID. No.
(UERL/AIR/FPS/RM/18)
Rotameter
Ecotech Instruments (Greater Noida)
ID No.
(UERL/MASTER/AIR/RM/01)
EI – CCS/FF/RF/1956
Date of Cali.: 18.08.2015
2. Time Totalizer
ID. No.
(UERL/AIR/FPS/TT/18)
Ecotech Instruments (Greater Noida)
ID. No.
(UERL/MASTER/AIR/TT/aa/01)
EI – CCS/ET/TT/2446
Date of Cali.: 22.09.2016
UNCERTAINTY MEASUREMENT: Rotameter : ± 0.475 LPM
UNCERTAINTY MEASUREMENT: Time Totalizer : ± 0.031 hour
The reported uncertainty is the expanded uncertainty in measurement at 95 % Confidence level with coverage fact
or k = 2 which corresponds to coverage probability of approximately 95 % of normal distribution.