ENVIRONMENTAL MANAGEMENT SYSTEM AT ZAGREB INTERNATIONAL ... · Installation of air monitoring...
Transcript of ENVIRONMENTAL MANAGEMENT SYSTEM AT ZAGREB INTERNATIONAL ... · Installation of air monitoring...
ENVIRONMENTAL MANAGEMENT SYSTEM
AT ZAGREB INTERNATIONAL AIRPORT
Sub Header
Small Sub Header
Text
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
Content:
New Passenger Terminal ProjectEnvironmental Management System
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
Shareholders of the Zagreb International Airport:
The financial lenders : European Investment Bank (EIB) IFC Unicredit Bank Austria Deutsche Bank
MZLZ
ADP
20.77 %
BBI
20.77 %
TAV Airports
15.0 %
Viadukt
5.11 %
MargueriteFund
20.77 %
IFC
17.58 %
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
65 000 m2 Floor area
35 000 m3 Concrete (NPT)
5 000 tons Rebar
2.000 tons Steel structure
3D Frame Roof
35.000 m2 Roofing
500.000 m3 Excavation
40.000 m3 Concrete
35.000 m Drainage
250.000 m2 Asphalt
8 Contact stands (PBBs)
Project in numbers:
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
Integrated Management System at Zagreb International Airport
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
Environmental Management System
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
Noise Management - inputsAir Traffic Act
(Official Gazette, No. 69/09, 84/11, 54/13, 127/13, 92/14
Ordinance on the establishment of rules andprocedures regarding implementation of operatingrestrictions for aircraft noise at the airports in theterritory of the Republic of Croatia (Official Gazette, No. 39/13)
ICAO Annex 16, Volume 1, Aircraft Noise
2016 Noise Reduction Action Plan
Study of Environmental Impact
Environmental Impact Decission
2016 Environmental Action Plan
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
Noise Monitoring Terminal – Facility map
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
The Results of noise level Monitoring from January up to July 2016
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
Noise – operating procedures with ATC and airlines
Operating procedure “Precise approach supported by satellite technology”
Operating procedure “Continuous Descent Approach - CDA”
Operating procedure “Low Power – Low Drag“
Less using of reverse thrust during evening and night when safety conditionsalow
Operating procedure for “Continuous Climb Operations“
Testing of aircraft engines on the airport surfaces
Using GPU instead of APU
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
Yearly cost (in Eur) of Noise Management
Implementation of Noisemonitoring stations
61 188
ATC Radar parameters 9 876
Renting space for NMT 2 688
Total: 73 752
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
Waste Management - inputsLaw on Sustainable Waste Management
(Official gazette No. 94/13)
Ordinance on Waste Management (Official gazette No. 23/14, 51/14)
Ordinance on Waste Catalogue(Official gazette No. 90/15)
Other regulations for special waste categories
2016 Environmental Action Plan
Study of Environmental Impact
Environmental Impact Decission
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
Waste – Location of Containers for Municipal Waste
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
Waste – Location of Containers for Paper
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
Waste – Location of Containers for Glass
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
Waste – Location of Containers for Wood
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
Waste – Location of Containers for Plastic
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
Produced Waste in 2015
Total Waste Kg
Hazardous Waste 454
Non-hazardous Waste 110.408
Total 110.862
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
Produced Waste Type in 2015
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
Produced Hazardous Waste in 2015
MZLZ Environmental Committee Meeting15.03.2016
Gabrijela ŠPOLJAR,Quality Manager
22
Key numberWASTE kg
15 01 10*packaging containing residues of or contaminatedby dangerous substances
256
13 07 03* other fuels (including mixtures)
88
20 01 21*fluorescent tubes and other mercury-containing waste
110
Total 454
Air Management - inputs
Ordinance on Monitoring Air Quality(Official gazette No. 3/13)
Law on Air Protection (Official gazette No. 130/11, 47/14)
Law on Environment Protection (Official gazette No. 80/13, 78/15)
Ordinance on Monitoring Emissions of Pollutants into the Air from Stationary Sources
(Official gazette No. 129/12, 97/13)
Ordinance on Monitoring Emissions of Greenhouse Gasesin the Republic of Croatia
(Official gazette No. 134/12)
Study of Environmental Impact
Environmental Impact Decission2016 Environmental Action Plan
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
Stationary and Diffuse Sources of Air Pollution at Zagreb International Airport
Parts of the operation The main roads in the affected project zone
Approach / Takeoff – PR/UZ Eastern bypass of VelikaGorica – D31
The Apron at the Terminal –Aircraft idling- ST
D408 - Western approach ZLZ
Landing - SL D30 - Northern bypass of Velika Gorica
Takeoff / Climbing of Aircraft -UZ
A 11 – Motorway
Parking lots – P1, P2 A3 - Motorway
Energy plant - EPlaned road – N (year: 2040)
The main roads in the area- MZLZ
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
Stationary Sources of Air pollution
Measuring and analysing emission of:
• NO2 • CO
Two sources:
Medium combustion plants: boiler TPK, No: 18450, and Small combustion plants: boiler Orometal no: 408, Orometal no:409, Toplota no:
305-106
Measuring points
Boiler
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
Diffuse Sources of Air pollution
Measuring and analysing air quality parameters:
• carbon monoxide (CO), • surface ozone, nitrogen oxides (NOx) expressed as nitrogen dioxide (NO2),• suspended particulates PM10 • benzo(a)pyrene (BaP) in suspended particulates PM10.
Parallel monitoring of weather parameters:
• temperature, • pressure, • relative moisture, • wind direction• speed
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
Implementation of Air Monitoring Station
Yearly cost (in Eur) of air monitoring
Installation of air monitoring station 75 040
Maintenance and continuous air quality monitoring - parameters: CO, NOX, NO2
33 784
Continuous air quality monitoring -parameters: PM10, BAP
12 773
Monitoring of weather parameters 2 855
Total: 124 452
MZLZ Environmental Management System 21.09.2016
Gabrijela ŠPOLJAR,Quality Manager
THANK YOU!
Questions…
MZLZ Environmental Management System 21.09.2016