Enter XX or Calendar Date Quality/permits/2018_Public_Notice... · 10560R00 N/A XXXX, 2018 XXXX,...

12
Enter XX or Calendar Date James Harris CEO US Operations Malec Brothers Transport, LLC 3600 S College Rd, Suite E-200 Wilmington, NC 28412 SUBJECT: Air Quality Permit No. 10560R00 Facility ID: 2400165 Malec Brothers Transport, LLC Wilmington Columbus County Fee Class: Title V PSD Class: Minor Dear Mr. Harris: In accordance with your completed Air Quality Permit Application for a new permit received November 30, 2017, we are forwarding herewith Air Quality Permit No. 10560R00 to Malec Brothers Transport, LLC 1408 Cronly Drive, Delco, Columbus County, North Carolina authorizing the construction and operation, of the emission sources and associated air pollution control devices specified herein. Please note the records retention requirements are contained in General Condition 2 of the General Conditions and Limitations. If any parts, requirements, or limitations contained in this Air Quality Permit are unacceptable to you, you have the right to request a formal adjudicatory hearing within 30 days following receipt of this permit, identifying the specific issues to be contested. Such a request will stay the effectiveness of the entire permit. This hearing request must be in the form of a written petition, conforming to NCGS (North Carolina General Statutes) 150B-23, and filed with both the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, North Carolina 27699-6714. The form for requesting a formal adjudicatory hearing may be obtained upon request from the Office of Administrative Hearings. Please note that this permit will be stayed in its entirety upon receipt of the request for a hearing. Unless a request for a hearing is made pursuant to NCGS 150B-23, this Air Quality Permit shall be final and binding. You may request modification of your Air Quality Permit through informal means pursuant to NCGS 150B-22. This request must be submitted in writing to the Director and must identify the specific provisions or issues for which the modification is sought. Please note that this Air Quality Permit will become final and binding regardless of a request for informal modification unless a request for a hearing is also made under NCGS 150B-23. Unless exempted by a condition of this permit or the regulations, construction of new air pollution sources or air cleaning devices, or modifications to the sources or air cleaning devices described in this permit must be covered under a permit issued by the Division of Air Quality prior to construction. Failure to do so is a violation of G.S. 143-215.108 and may subject the Permittee to civil or criminal penalties as described in G.S. 143-215.114A and 143-215.114B.

Transcript of Enter XX or Calendar Date Quality/permits/2018_Public_Notice... · 10560R00 N/A XXXX, 2018 XXXX,...

Enter XX or Calendar Date

James Harris

CEO US Operations

Malec Brothers Transport, LLC

3600 S College Rd, Suite E-200

Wilmington, NC 28412

SUBJECT: Air Quality Permit No. 10560R00

Facility ID: 2400165

Malec Brothers Transport, LLC

Wilmington

Columbus County

Fee Class: Title V

PSD Class: Minor

Dear Mr. Harris:

In accordance with your completed Air Quality Permit Application for a new permit received

November 30, 2017, we are forwarding herewith Air Quality Permit No. 10560R00 to Malec Brothers

Transport, LLC 1408 Cronly Drive, Delco, Columbus County, North Carolina authorizing the construction

and operation, of the emission sources and associated air pollution control devices specified herein. Please

note the records retention requirements are contained in General Condition 2 of the General Conditions and

Limitations.

If any parts, requirements, or limitations contained in this Air Quality Permit are unacceptable to you,

you have the right to request a formal adjudicatory hearing within 30 days following receipt of this permit,

identifying the specific issues to be contested. Such a request will stay the effectiveness of the entire permit.

This hearing request must be in the form of a written petition, conforming to NCGS (North Carolina General

Statutes) 150B-23, and filed with both the Office of Administrative Hearings, 6714 Mail Service Center,

Raleigh, North Carolina 27699-6714. The form for requesting a formal adjudicatory hearing may be obtained

upon request from the Office of Administrative Hearings. Please note that this permit will be stayed in its

entirety upon receipt of the request for a hearing. Unless a request for a hearing is made pursuant to NCGS

150B-23, this Air Quality Permit shall be final and binding.

You may request modification of your Air Quality Permit through informal means pursuant to NCGS

150B-22. This request must be submitted in writing to the Director and must identify the specific provisions

or issues for which the modification is sought. Please note that this Air Quality Permit will become final and

binding regardless of a request for informal modification unless a request for a hearing is also made under

NCGS 150B-23.

Unless exempted by a condition of this permit or the regulations, construction of new air

pollution sources or air cleaning devices, or modifications to the sources or air cleaning devices

described in this permit must be covered under a permit issued by the Division of Air Quality prior

to construction. Failure to do so is a violation of G.S. 143-215.108 and may subject the Permittee to

civil or criminal penalties as described in G.S. 143-215.114A and 143-215.114B.

Mr. James Harris

TBD

Page 2

This Air Quality Permit shall be effective from (Enter Permit Issuance Date) until (Enter Permit

Expiration Date 8 years from issuance date), is nontransferable to future owners and operators, and shall

be subject to the conditions and limitations as specified therein.

This permit is the result of a request for a new Title V permit; an annual emissions inventory

requirement (for TV) is included. The Permittee is responsible for carefully reading the entire permit

and evaluating the requirements of each permit stipulation. The Permittee shall comply with all

terms, conditions, requirements, limitations and restrictions set forth in this permit. Noncompliance

with any permit condition is grounds for enforcement action, for permit termination, revocation and

reissuance, or modification, or for denial of a permit renewal application.

Should you have any questions concerning this matter, please contact Urva Patel at (919) 707-8405

and [email protected] .

Sincerely yours,

William D. Willets, P.E., Chief, Permitting Section

Division of Air Quality, NCDEQ

Enclosure

c: Wilmington Regional Office

Central Files

Connie Horne (cover letter only)

State of North Carolina

Department of Environmental Quality

Division of Air Quality

AIR QUALITY PERMIT

Permit No. Replaces Permit No.(s) Effective Date Expiration Date

10560R00 N/A XXXX, 2018 XXXX, 2026

Until such time as this permit expires or is modified or revoked, the below named Permittee is permitted to construct and operate

the emission source(s) and associated air pollution control device(s) specified herein, in accordance with the terms, conditions,

and limitations within this permit. This permit is issued under the provisions of Article 21B of Chapter 143, General Statutes of

North Carolina as amended, and Title 15A North Carolina Administrative Codes (15A NCAC), Subchapters 02D and 02Q, and

other applicable Laws.

Pursuant to Title 15A NCAC, Subchapter 02Q, the Permittee shall not construct, operate, or modify any emission source(s) or air

pollution control device(s) without having first submitted a complete Air Quality Permit Application to the permitting authority

and received an Air Quality Permit, except as provided in this permit.

Permittee: Malec Brothers Transport, LLC

Facility ID: 2400165

Facility Site Location: 1408 Cronly Drive

City, County, State, Zip: Delco, Columbus County, North Carolina, 28436

Mailing Address: 3600 S College Road, Suite E-200

City, State, Zip: Wilmington, North Carolina, 28412

Application Number: 2400165.17A

Complete Application Date: December 8, 2017

Primary SIC Code: 7342

Division of Air Quality, Wilmington Regional Office

Regional Office Address: 127 Cardinal Drive Extension

Wilmington, North Carolina, 28405

Table of Contents

SECTION 1: PERMITTED EMISSION SOURCE (S) AND ASSOCIATED

AIR POLLUTION CONTROL DEVICE (S) AND APPURTENANCES

SECTION 2: SPECIFIC LIMITATIONS AND CONDITIONS

2.1 Emission Source(s) Specific Limitations and Conditions (Including specific requirements, testing,

monitoring, recordkeeping, and reporting requirements)

SECTION 3: GENERAL PERMIT CONDITIONS

ATTACHMENT

List of Acronyms

Air Quality Permit No. 10560R00

Page 3

SECTION 1- PERMITTED EMISSION SOURCE (S) AND ASSOCIATED AIR

POLLUTION CONTROL DEVICE (S) AND APPURTENANCES The following table contains a summary of all permitted emission sources and associated air pollution control devices and appurtenances:

Page Nos.

Emission

Source

ID No. Emission Source Description

Control

Device

ID No. Control Device Description

3 ES-1 One Fumigation process utilizing

methyl bromide on export

commodities in shipping containers

N/A N/A

SECTION 2 - SPECIFIC LIMITATIONS AND CONDITIONS

2.1 Emission Source(s) and Control Devices(s) Specific Limitations and Conditions The emission source(s) and associated air pollution control device(s) and appurtenances listed below are subject to the following

specific terms, conditions, and limitations, including the testing, monitoring, recordkeeping, and reporting requirements as

specified herein:

A. One Fumigation process utilizing methyl bromide on export commodities in shipping containers

(ID No. ES-1) The following table provides a summary of limits and standards for the emission source(s) described above:

Regulated Pollutant Limits/Standards Applicable Regulation

Fugitive Dust State-enforceable only

15A NCAC 02D .0540

Volatile organic compounds Less than 250 tons per year 15A NCAC 02Q .0317

(PSD Avoidance)

Hazardous Air Pollutants 112(g): Case-By-Case MACT 15A NCAC 02D .1112

1. Any air emission sources or control devices authorized to construct and operate above must be operated and maintained in

accordance with the provisions contained herein. The Permittee shall comply with applicable Environmental Management

Commission Regulations, including Title 15A North Carolina Administrative Code (NCAC), Subchapter 02D .0202, 02D

.0535, 02D .0540, 02D .1112, 02Q .0317, and 02Q .0504.

2. PERMIT RENEWAL AND EMISSION INVENTORY REQUIREMENT

The Permittee, at least 90 days prior to the expiration date of this permit, shall request permit renewal by letter in

accordance with 15A NCAC 02Q .0304(d) and (f). Pursuant to 15A NCAC 02Q .0203(i), no permit application fee is

required for renewal of an existing air permit (without a modification request). The renewal request (with AA application

form) should be submitted to the Regional Supervisor, DAQ. Also, at least 90 days prior to the expiration date of this

permit, the Permittee shall submit the air pollution emission inventory report (with Certification Sheet) in accordance with

15A NCAC 02D .0202, pursuant to N.C. General Statute 143-215.65. The report shall be submitted to the Regional

Supervisor, DAQ and shall document air pollutants emitted for the 2024 calendar year.

3. NOTIFICATION REQUIREMENT

As required by 15A NCAC 02D .0535, the Permittee of a source of excess emissions that last for more than four hours and

that results from a malfunction, a breakdown of process or control equipment or any other abnormal conditions, shall:

a. Notify the Director or his designee of any such occurrence by 9:00 a.m. eastern time of the Division's next business

day of becoming aware of the occurrence and describe:

Air Quality Permit No. 10560R00

Page 4

i. the name and location of the facility,

ii. the nature and cause of the malfunction or breakdown,

iii. the time when the malfunction or breakdown is first observed,

iv. the expected duration, and

v. an estimated rate of emissions.

b. Notify the Director or his designee immediately when the corrective measures have been accomplished.

This reporting requirement does not allow the operation of the facility in excess of Environmental Management

Commission Regulations.

4. FUGITIVE DUST CONTROL REQUIREMENT

a. As required by 15A NCAC 02D .0540 "Particulates from Fugitive Dust Emission Sources," the Permittee shall not

cause or allow fugitive dust emissions to cause or contribute to substantive complaints or excess visible emissions

beyond the property boundary. If substantive complaints are received or excessive fugitive dust emissions from the

facility are observed beyond the property boundaries for six minutes in any one hour (using Reference Method 22 in

40 CFR, Appendix A), the owner or operator may be required to submit a fugitive dust plan as described in 15A

NCAC 02D .0540(f).

b. "Fugitive dust emissions" means particulate matter that does not pass through a process stack or vent and that is

generated within plant property boundaries from activities such as: unloading and loading areas, process areas

stockpiles, stock pile working, plant parking lots, and plant roads (including access roads and haul roads).

5. 15A NCAC 02Q .0317: AVOIDANCE CONDITION

for 15A NCAC 02D .0530: PREVENTION OF SIGNIFICANT DETERIORATION

a. In order to avoid applicability of this regulation, the volatile organic compound (VOC) emissions from this source (ID

No. ES-1) shall be less than 250 tons per consecutive 12-month period.

Monitoring/Recordkeeping [15A NCAC 02D .0605(b)]

b. Calculations of VOC emissions per month shall be made at the end of each month. VOC emissions shall be determined

by multiplying the total amount of each type of VOC-containing material consumed during the month by the VOC

content of the material.

c. Calculations and the total amount of VOC emissions shall be recorded monthly in a logbook (written or electronic

format).

Reporting [15A NCAC 02D .0508(b)]

d. The Permittee shall submit a semi-annual summary report, acceptable to the Regional Air Quality Supervisor, of

monitoring and recordkeeping activities postmarked on or before January 30 of each calendar year for the preceding

six-month period between July and December, and July 30 of each calendar year for the preceding six-month period

between January and June. The report shall contain the monthly VOC emissions for the previous 17 months. The

emissions must be calculated for each of the 12-month periods over the previous 17 months.

6. 15A NCAC 02D .1112: CASE-BY-CASE MAXIMUM ACHIEVABLE CONTROL TECHNOLOGY

Applicability [40 CFR 63.1(b), 52, 53, 54]

a. For this source (stationary source located at a major source of HAP emissions) the Permittee shall comply with all

applicable provisions, including the general compliance requirements, operational restrictions, ambient monitoring,

monitoring, recordkeeping and reporting requirements contained in Environmental Management Commission

Standard 15A NCAC 02D .1112 “Case-by-Case Maximum Achievable Control Technology” as promulgated in 40

CFR Part 63, Subpart A “General Provisions” and Subpart B, “Requirements for Control Technology Determinations

for Major Sources in Accordance with Clean Air Act Sections, Sections 112(g) and 112(j)”.

General Compliance Requirements

b. At all times, the Permittee shall operate and maintain any affected source, including associated air pollution control

equipment and monitoring equipment, in a manner consistent with safety and good air pollution control practices for

minimizing emissions. Determination of whether such operation and maintenance procedures are being used will be

based on information available to the Administrator that may include, but is not limited to ambient monitoring results,

Air Quality Permit No. 10560R00

Page 5

review of operation and maintenance procedures, review of operation and maintenance records, and inspection of the

source.

I. The Permittee shall send an Initial Notification of commencement of operations to the Regional Office within 15-

days of start-up.

II. Prior to the initial fumigation activity, the Permittee shall notify the adjacent neighbors (residents and businesses)

of fumigation operations in writing providing the information found in the Emergency Preparedness measures of

the EPA registered and approved methyl bromide product label “Information for Neighbors”.

III. Signs shall be posted prior to initial and all subsequent fumigation operations. The signs must contain the same

information as that mandated by EPA registered and approved methyl bromide product label for placarding of

treatment areas. The signs must be visible and legible at the fence or property boundary closest to any public

right-of-way, adjacent residence(s), and business(es). The signs must remain in place until completion of each

aeration process.

IV. A wind sock shall be installed on site.

Operational Limitations

c. The Permittee shall comply with the following operational restrictions at all times during fumigation. [40 CFR 63.6]

I. The Permittee shall only use EPA registered and approved methyl bromide product as a fumigant at this location.

The use of any other fumigant will require a permit modification.

II. The Permittee shall conduct ambient monitoring for the initial fumigation activity in accordance with the ambient

monitoring requirements specified in Section 2.1 A.6.h. below. The Permittee shall be limited to a maximum

total charge of methyl bromide (pounds) per day established by the way of ambient monitoring results during the

initial fumigation activity.

III. Once a maximum daily charge limit is established which results in zero parts per million (ppm) methyl bromide

concentration at the downwind property boundary, the Permittee shall submit an Administrative Amendment to

the permit within 10 days of establishing the limit requesting a daily limit on the methyl bromide charge limit.

IV. The Permittee shall not initiate another fumigation activity if there is an existing fumigation activity still in

progress.

V. If methyl bromide concentrations are measured greater than zero at the property boundary downwind of the

treatment zone, the Permittee shall:

1. Take immediate measures to minimize the emissions.

2. Notify the DAQ Regional Supervisor immediately (no later than the next day).

3. Reduce the volume of the next fumigation by a volume equal to and/or no less than a standard shipping

container (meaning 2700 cubic feet). Repeat the property boundary ambient monitoring requirements

specified in Section 2.1 A.6.h below. This reduction in volume and the associated ambient monitoring shall

be repeated until a fumigation cycle occurs that results in no methyl bromide concentrations greater than zero

ppm at the property boundary.

4. Conduct an internal audit of the excursion, initiated no later than three days after the end of the excursion.

The audit conclusions shall be provided to the DAQ Regional Supervisor in a written report within 10

business days of the end of the event. The report shall include the details of the actions taken to minimize

emissions of methyl bromide. The report shall include an application for an Administrative Amendment to

the permit restricting the daily methyl bromide charge limit to the amount identified in Section 2.1 A.6.c.V.3

above which results in zero ppm of methyl bromide at the property boundary during aeration.

Should the methyl bromide concentrations be measured at greater than zero at the property boundary downwind

of the treatment zone and the Administrative Amendment in Section 2.1 A.6.c.V.4 above not be submitted, the

Regional Office Supervisor may initiate a reopening of the Air Permit for cause as provided by 15A NCAC

02Q .0309 requiring a modification of the permit to further restrict the daily and yearly methyl bromide usage in

the Operating Limitation(s) in Section 2.1 A.6.c.II above.

Definitions and Nomenclature

d. For the purposes of this permit condition, the definitions and nomenclature contained in 40 CFR 63.2 shall apply.

General Provisions [40 CFR 63.7565]

e. The Permittee shall comply with the General Provisions as applicable pursuant to 40 CFR Part 63, Subpart A.

Air Quality Permit No. 10560R00

Page 6

Compliance Dates [40 CFR 63.6(b)]

f. The Permittee shall achieve compliance upon initial start-up of operation.

Notification of Compliance Status

g. The Permittee shall submit a Notification of Compliance Status within 60 days of initial start-up. The Notification

shall contain the following:

I. Certification of compliance with the following:

1. General compliance requirements in Section 2.1 A.6.b.

2. Operational Limitations in Section 2.1 A.6.c.

3. Ambient monitoring requirements in Section 2.1 A.6.h.

4. Monitoring requirements in Section 2.1 A.6.i.

5. Recordkeeping requirement in Section 2.1 A.6.j.

6. Reporting requirements in Section 2.1 A.6.l.

II. A signed certification that the Permittee has met the compliance requirements in Section 2.1 A.6.g.I above.

The notification must be signed by a responsible official and postmarked before the close of business on the 60 th day

following the completion of the initial start-up.

Ambient Monitoring

h. To establish an acceptable operational limitation for the total daily maximum charge of methyl bromide, resulting in

zero concentrations at the property boundary, the Permittee shall conduct ambient monitoring in accordance with the

following:

I. The initial fumigation performed under this permit requires monitoring downwind of the emission source and at

a distance no greater than the distance between the emission source and the closest property boundary (see III

below). The total amount of methyl bromide used during initial fumigation shall establish the maximum daily

methyl bromide charge rate. The daily charge rate can be increased at any time using the procedures in this

Section (h).

II. Monitoring shall begin at the beginning of the aeration period (active and/or passive aeration). Observed methyl

bromide concentrations shall be recorded every 3 minutes at the start of aeration (i.e., when first container is

opened) and continuing until 15 minutes after the last container is opened. In the case of active aeration, the rate

of aeration cannot be increased after the end of the monitoring schedule.

III. Subsequent to initial monitoring in 2.1 A.6.h.I above, all monitoring shall be conducted downwind of the emission

source and at a distance no greater than the distance between the emission source and the closest property

boundary.

IV. If at any time during ambient monitoring, a reading of other than zero is obtained at the downwind property

boundary, aeration shall be halted until five three-minute (15 minutes) consecutive intervals of readings

demonstrate zero ppm of methyl bromide at the downwind property boundary. The ambient monitoring in Section

2.1 A.6.h.II above shall resume, when aeration resumes.

V. When the maximum daily charge (pounds) of methyl bromide is established, normal production shall begin and

one quarterly monitoring event per quarter shall be conducted for four quarters after the quarter in which the

maximum daily methyl bromide charge limit was established.

VI. If no methyl bromide readings above zero ppm are documented at the property boundary for four quarterly events,

the Permittee may reduce monitoring to two ambient monitoring events, to be conducted semi-annually as

specified in h.II., III. And IV above.

VII. All quarterly and semi-annual ambient monitoring (see subsection h.VIII, below regarding semi-annual ambient

monitoring) shall be conducted during fumigation cycles (loads) using at least 90% of the maximum daily methyl

bromide charge rate. If during any quarter or subsequent semi-annual period, less than 90% of the maximum

daily methyl bromide charge established in 2.1 A.6.h.IV is used, ambient monitoring is not required for that

quarter or semi-annual period. Monitoring shall resume when 90% of the maximum daily methyl bromide charge

is used in a quarter or semi-annual period until the ambient monitoring in h.V and VI are satisfied.

VIII. Once two semi-annual ambient monitoring reports result in zero ppm methyl bromide readings at the property

boundary, the Permittee may discontinue monitoring.

IX. If during any of the quarterly or semi-annual ambient monitoring, a concentration of methyl bromide is measured

greater than zero at the property boundary, the Permittee shall follow the procedures in c.V (above).

Air Quality Permit No. 10560R00

Page 7

X. The methyl bromide ambient monitoring device shall be capable of reading to zero ppm with no less than a +/-

0.5 ppm accuracy. Proper monitoring equipment shall be used and calibrated such that the detection level is no

less than 0.5 ppm accuracy to a range of zero

Monitoring

i. The Permittee shall monitor the following information during each fumigation cycle and enter the readings in a

logbook (written or electronic format):

I. Total daily methyl bromide charge in pounds per day.

II. Wind direction and wind speed during the first ten minutes of aeration for all fumigation events.

j. Recordkeeping

The Permittee shall maintain the following records which shall be made available upon request:

I. A copy of each notification and report submitted to comply with this Subpart, including all documentation

supporting any Initial Notification, Notification of Compliance Status, and quarterly compliance reports that have

been submitted.

II. The amount of methyl bromide used daily, monthly and calculated 12-month rolling totals assuming all fumigant

used is emitted to the atmosphere.

III. The ambient monitoring data collected pursuant to Section 2.1 A.6.h above shall be recorded with the date, time,

location of commodity being fumigated and the ambient monitoring locations indicated on a site map with the

wind direction and wind speed indicated.

IV. Any records of methyl bromide concentrations greater than zero ppm at the property boundary shall be retained

for the life of the permit.

k. The Permittee shall:

I. Maintain records in a form suitable and readily available for expeditious review.

II. Unless otherwise noted in this condition, keep each record on site for at least 2 years after the date of each

occurrence, measurement, maintenance, corrective action, report, or record.

III. Unless otherwise noted in this condition, keep each record for 5 years following the date of each occurrence,

measurement, maintenance, corrective action, report, or record; the Permittee can keep the records offsite for the

remaining 3 years.

Reporting [15A NCAC 02D .0605(b)]

l. The Permittee shall submit a summary report, acceptable to the Regional Air Quality Supervisor, of monitoring and

recordkeeping activities postmarked on or before January 30 of each calendar year for the preceding three-month

period between October and December, April 30 of each calendar year for the preceding three-month period between

January and March, July 30 of each calendar year for the preceding three-month period between April and June, and

October 30 for the calendar year for the preceding three-month period between July and September. The report shall

contain the following:

I. Company name, address and facility ID number;

II. Monthly and calculated 12-month rolling total methyl bromide usage for each quarter;

III. Date of the report and the beginning and ending dates of each quarterly reporting period;

IV. Quarterly reports consisting of a summary of monitoring data recorded in Sections 2.1 A.6.h and i above.

V. If there are no deviations from the requirements of Section 2.1 A.6.c above (Operational Limitations), a statement

that there were no deviations from the Operational Limitations during the reporting period.

m. If there is a deviation from an Operational Limitation during the reporting period, the report must contain the following

information:

I. A description of the deviation and the Operational Limitation which the Permittee deviated; and

II. Information on the number, duration, and cause of deviations (including unknown cause) as applicable, and the

corrective action(s) taken.

7. TITLE V PERMIT APPLICATION SUBMITTAL REQUIREMENT

The Permittee shall file a Title V Air Quality Permit Application pursuant to 15A NCAC 02Q .0504 within 12 months of

start-up of this source.

Air Quality Permit No. 10560R00

Page 8

SECTION 3 - GENERAL CONDITIONS AND LIMITATIONS

1. In accordance with G.S. 143-215.108(c)(1), TWO COPIES OF ALL DOCUMENTS, REPORTS, TEST DATA,

MONITORING DATA, NOTIFICATIONS, REQUESTS FOR RENEWAL, AND ANY OTHER INFORMATION

REQUIRED BY THIS PERMIT shall be submitted to the:

Regional Supervisor

North Carolina Division of Air Quality

Wilmington Regional Office

127 Cardinal Drive Extension

Wilmington, NC 28405

910-796-7215

For identification purposes, each submittal should include the facility name as listed on the permit, the facility

identification number, and the permit number.

2. RECORDS RETENTION REQUIREMENT - In accordance with 15A NCAC 02D .0605, any records required by the

conditions of this permit shall be kept on site and made available to DAQ personnel for inspection upon request. These

records shall be maintained in a form suitable and readily available for expeditious inspection and review. These

records must be kept on site for a minimum of 2 years, unless another time period is otherwise specified.

3. ANNUAL FEE PAYMENT - Pursuant to 15A NCAC 02Q .0203(a), the Permittee shall pay the annual permit fee

within 30 days of being billed by the DAQ. Failure to pay the fee in a timely manner will cause the DAQ to initiate

action to revoke the permit.

4. EQUIPMENT RELOCATION - In accordance with 15A NCAC 02Q .0301, a new air permit shall be obtained by the

Permittee prior to establishing, building, erecting, using, or operating the emission sources or air cleaning equipment

at a site or location not specified in this permit.

5. REPORTING REQUIREMENT - In accordance with 15A NCAC 02Q .0309, any of the following that would result

in previously unpermitted, new, or increased emissions must be reported to the Regional Supervisor, DAQ:

a. changes in the information submitted in the application regarding facility emissions;

b. changes that modify equipment or processes of existing permitted facilities; or

c. changes in the quantity or quality of materials processed.

If appropriate, modifications to the permit may then be made by the DAQ to reflect any necessary changes in the

permit conditions. In no case are any new or increased emissions allowed that will cause a violation of the emission

limitations specified herein.

6. In accordance with 15A NCAC 02Q .0309, this permit is subject to revocation or modification by the DAQ upon a

determination that information contained in the application or presented in the support thereof is incorrect, conditions

under which this permit was granted have changed, or violations of conditions contained in this permit have occurred.

In accordance with G.S. 143-215.108(c)(1), the facility shall be properly operated and maintained at all times in a

manner that will effect an overall reduction in air pollution. Unless otherwise specified by this permit, no emission

source may be operated without the concurrent operation of its associated air cleaning device(s) and appurtenances.

7. In accordance with G.S. 143-215.108(c)(1), this permit is nontransferable by the Permittee. Future owners and

operators must obtain a new air permit from the DAQ.

8. In accordance with G.S. 143-215.108(c)(1), this issuance of this permit in no way absolves the Permittee of liability

for any potential civil penalties which may be assessed for violations of State law which have occurred prior to the

effective date of this permit.

Air Quality Permit No. 10560R00

Page 9

9. In accordance with G.S. 143-215.108(c)(1), this permit does not relieve the Permittee of the responsibility of

complying with all applicable requirements of any Federal, State, or Local water quality or land quality control

authority.

10. In accordance with 15A NCAC 02D .0605, reports on the operation and maintenance of the facility shall be submitted

by the Permittee to the Regional Supervisor, DAQ at such intervals and in such form and detail as may be required by

the DAQ. Information required in such reports may include, but is not limited to, process weight rates, firing rates,

hours of operation, and preventive maintenance schedules.

11. A violation of any term or condition of this permit shall subject the Permittee to enforcement pursuant to G.S. 143-

215.114A, 143-215.114B, and 143-215.114C, including assessment of civil and/or criminal penalties.

12. Pursuant to North Carolina General Statute 143-215.3(a)(2), no person shall refuse entry or access to any authorized

representative of the DAQ who requests entry or access for purposes of inspection, and who presents appropriate

credentials, nor shall any person obstruct, hamper, or interfere with any such representative while in the process of

carrying out his official duties. Refusal of entry or access may constitute grounds for permit revocation and assessment

of civil penalties.

13. In accordance with G.S. 143-215.108(c)(1), this permit does not relieve the Permittee of the responsibility of

complying with any applicable Federal, State, or Local requirements governing the handling, disposal, or incineration

of hazardous, solid, or medical wastes, including the Resource Conservation and Recovery Act (RCRA) administered

by the Division of Waste Management.

14. PERMIT RETENTION REQUIREMENT - In accordance with 15A NCAC 02Q .0110, the Permittee shall retain a

current copy of the air permit at the site. The Permittee must make available to personnel of the DAQ, upon request,

the current copy of the air permit for the site.

15. CLEAN AIR ACT SECTION 112(r) REQUIREMENTS - Pursuant to 15A NCAC 02D .2100 "Risk Management

Program," if the Permittee is required to develop and register a risk management plan pursuant to Section 112(r) of

the Federal Clean Air Act, then the Permittee is required to register this plan with the USEPA in accordance with 40

CFR Part 68.

16. PREVENTION OF ACCIDENTAL RELEASES - GENERAL DUTY - Pursuant to Title I Part A Section 112(r)(1)

of the Clean Air Act "Hazardous Air Pollutants - Prevention of Accidental Releases - Purpose and General Duty,"

although a risk management plan may not be required, if the Permittee produces, processes, handles, or stores any

amount of a listed hazardous substance, the Permittee has a general duty to take such steps as are necessary to prevent

the accidental release of such substance and to minimize the consequences of any release. This condition is federally-

enforceable only.

17. GENERAL EMISSIONS TESTING AND REPORTING REQUIREMENTS - If emissions testing is required by this

permit, or the DAQ, or if the Permittee submits emissions testing to the DAQ in support of a permit application or to

demonstrate compliance, the Permittee shall perform such testing in accordance with 15A NCAC 02D .2600 and

follow all DAQ procedures including protocol approval, regional notification, report submittal, and test results

approval.

Permit issued this the xx day of Month, 2018.

NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION

_______________________________________

William D. Willets, P.E., Chief, Permitting Section

Division of Air Quality, NCDEQ

By Authority of the Environmental Management Commission

Air Permit No. 10560R00

Air Quality Permit No. 10560R00

Page 10

ATTACHMENT

List of Acronyms

AOS Alternate Operating Scenario

BACT Best Available Control Technology

Btu British thermal unit

CAA Clean Air Act

CAIR Clean Air Interstate Rule

CEM Continuous Emission Monitor

CFR Code of Federal Regulations

DAQ Division of Air Quality

DEQ Department of Environmental Quality

EMC Environmental Management Commission

EPA Environmental Protection Agency

FR Federal Register

GACT Generally Available Control Technology

HAP Hazardous Air Pollutant

MACT Maximum Achievable Control Technology

NAA Non-Attainment Area

NCAC North Carolina Administrative Code

NCGS North Carolina General Statutes

NESHAP National Emission Standards for Hazardous Air Pollutants

NOX Nitrogen Oxides

NSPS New Source Performance Standard

OAH Office of Administrative Hearings

PM Particulate Matter

PM10 Particulate Matter with Nominal Aerodynamic Diameter of 10 Micrometers or Less

POS Primary Operating Scenario

PSD Prevention of Significant Deterioration

RACT Reasonably Available Control Technology

SIC Standard Industrial Classification

SIP State Implementation Plan

SO2 Sulfur Dioxide

tpy Tons Per Year

VOC Volatile Organic Compound