Enter Report Title Here - Home - CIMugcimug.ucaiug.org/Focus_Comms/AssetHealth/Public...

11
Sample Transformer Details Detailed information on a representative subset of the transformers is presented here to illustrate the range of instance modeling requirements encountered in the project. Three utility transformers were chosen (names are for reference purposes only and do not reflect the actual location of any transformer): Chattanooga Xf3 – a 230/115 kV transmission transformer with one tank Sumpter Xf56 – a 161/13.2/13.2 kV 3-winding transmission to distribution transformer with one tank Nashville Xf3 - a 765/345/34.5 kV autotransformer with tertiary, comprised of three single-phase tanks in a transformer bank Pictures of the three sample transformers are shown in Figures 1- 1, 1-2 and 1-3 and one-line schematics of the three sample transformers are provided in Figures 1-4, 1-5 and 1-6.

Transcript of Enter Report Title Here - Home - CIMugcimug.ucaiug.org/Focus_Comms/AssetHealth/Public...

Sample Transformer DetailsDetailed information on a representative subset of the transformers is presented here to illustrate the range of instance modeling requirements encountered in the project. Three utility transformers were chosen (names are for reference purposes only and do not reflect the actual location of any transformer):

Chattanooga Xf3 – a 230/115 kV transmission transformer with one tank Sumpter Xf56 – a 161/13.2/13.2 kV 3-winding transmission to distribution transformer with

one tank Nashville Xf3 - a 765/345/34.5 kV autotransformer with tertiary, comprised of three single-

phase tanks in a transformer bank Pictures of the three sample transformers are shown in Figures 1-1, 1-2 and 1-3 and one-line schematics of the three sample transformers are provided in Figures 1-4, 1-5 and 1-6.

Figure 1-1Chattanooga Xf3

Chattanooga Xf3 is a 230/115 kV transmission transformer with one tank.

Figure 1-2Sumpter Xf56

Sumpter Xf56 is a 161/13.2/13.2 kV 3-winding transmission to distribution transformer with one tank.

Figure 1-3One Tank of Nashville Xf3

Nashville Xf3 is a 765/345/34.5 kV autotransformer with a tertiary winding. The transformer is comprised of three single-phase tanks (one of which is shown in Figure 4-3 in the factory before it was shipped) in a transformer bank.

Figure 1-4One-Line Schematic of Chattanooga Xf3

Figure 1-5One-line Schematic of Sumpter Xf56

Magn

etic

Core

Input VoltageNeutral

Neutral

Phase In

Shunt Winding

Output Voltage

Input Voltage

(Subtransmission)

Figure 1-6One-line Schematic of Nashville Xf3

Input Voltage

NeutralNeutral

Phase In

Shunt Winding

Output Voltage

Delta Tertiary

Magn

etic

Core

Sample Transformer Instance drawings

Transformer Instance Drawings for Sample Transformers

Chattanooga Xf3 Transformer Instance Drawing

M

Asset

PowerTransformer

TransformerTank

TransformerTankEndphases: A

PowerTransformerEnd

TransformerTankEndphases: A

TransformerTankTransformerTankEndphases: B

TransformerTankEndphases: B

TransformerTank

TransformerTankEndphases: C

TransformerTankEndphases: C

Terminalphases: ABC

BaseVoltagenominalVoltage: 230

BaseVoltagenominalVoltage: 115

M MM

M M M

M M MM M M

Terminalphases: ABC

Terminalphases: A

Terminalphases: B

Terminalphases: C

Terminalphases: A

Terminalphases: B

Terminalphases: C

PowerTransformerEnd

M

Sumpter Xf56 Transformer Instance Drawing

Asset

PowerTransformer

TransformerTank

TransformerTankEndphases: A

PowerTransformerEnd

Pow

erTr

ansf

orm

erE

nd Tra

nsf

orm

erT

ank

En

dp

has

es: A

TransformerTankEndphases: A

TransformerTank

TransformerTankEndphases: B

Tra

nsf

orm

erT

ank

En

dp

has

es: B

TransformerTankEndphases: B

TransformerTank

TransformerTankEndphases: C

Tra

nsf

orm

erT

ank

En

dp

has

es: C

TransformerTankEndphases: C

PowerTransformerEnd

M

BaseVoltagenominalVoltage: 161

BaseVoltagenominalVoltage: 13.2

BaseVoltagenominalVoltage: 13.2

MM

M MM

M

M

MM

MMM

Terminalphases: ABC

Terminalphases: A

Terminalphases: B

Terminalphases: C

Terminalphases: ABC

Terminalphases: A

Terminalphases: B

Terminalphases: C

Term

inal

phas

es:

ABC

Term

ina

lph

ase

s: A

Term

ina

lph

ase

s: B

Term

ina

lph

ase

s: C

Nashville Xf3 Transformer Instance Drawing

NOTEThe above content is background material used in EPRI reports on asset health from 2011 – 2014, contributed to the CIMug Asset Health Focus Community for the furtherance of the CIM standard by Pat Brown, EPRI

PowerTransformer

Asset

TransformerTankTransformerTankEndphases: A

PowerTransformerEnd

Pow

erTr

ansf

orm

erEn

d Tra

nsf

orm

erT

ank

En

dp

has

es: A

TransformerTankEndphases: A

Asset

TransformerTankTransformerTankEndphases: B

Tra

nsf

orm

erT

ank

En

dp

has

es: B

TransformerTankEndphases: B

Asset

TransformerTankTransformerTankEndphases: C

Tra

nsf

orm

erT

ank

En

dp

has

es: C

TransformerTankEndphases: C

PowerTransformerEnd

M M

BaseVoltagenominalVoltage: 765

BaseVoltagenominalVoltage: 34.5

BaseVoltagenominalVoltage: 345

MM MM MMM MMM

M MM

M M M M M M

M

Terminalphases: ABC

Terminalphases: A

Terminalphases: B

Terminalphases: C

Terminalphases: ABC

Terminalphases: A

Terminalphases: B

Terminalphases: C

Term

inal

phas

es:

ABC

Term

inal

phas

es: A

Term

inal

phas

es: B

Term

inal

phas

es: C