CovereNodeB V100R003C00 Parameter ReferenceCopyright Huawei Technologies Co., Ltd. 2012. All rights reserved.No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.Trademarks and Permissionsand other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.All other trademarks and trade names mentioned in this document are the property of their respective holders.NoticeThe purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied.The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied.Huawei Technologies Co., Ltd.Address:Huawei Industrial BaseBantian, LonggangShenzhen 518129People's Republic of ChinaWebsite:http://www.huawei.comEmail:[email protected]

http://[email protected]

About This DocumentPurposeThis document describes eNodeB V100R003C00 parameters.Intended AudienceThis document is intended for: Network planners System engineers Field engineers Shift operators Site maintainers Network operatorsParameter Attribute DescriptionThe following table describes the attributes of each parameter.Parameter AttributeDescriptionMOManaged object of NEParameter IDSimple string for identifying a parameterParameter NameName of the parameterNENEs on which the parameter is setMML CommandMan Machine Language (MML) command related to the parameterMeaningDefinition, purpose, and protocols of the parameterIsKeyWhether the parameter is used to identify an MO instance.MandatoryWhether the parameter is mandatory for creating an MO instance.Dynamic AttributeWhether the parameter is dynamic for an MO. If the parameter is not dynamic, it can be added, modified, or removed; if the parameter is dynamic, it cannot.Feature IDID of the feature that uses the parameterFeature NameName of the feature that uses the parameterValue TypeParameter value typeGUI Value RangeParameter value range displayed on the GUIEnumeration Number/BitEnumeration number corresponding to the GUI value of a parameter of the enumeration type, or bit position corresponding to the GUI value of a parameter of the bit field type.UnitUnit for the GUI Value RangeActual Value RangeActual parameter value range corresponding to the GUI Value RangeDefault ValueInitial parameter value assigned by the system. There is no default value for a mandatory parameter. None indicates that there is no default value. For a bit field parameter, the value ON of a sub-parameter means that the bit representing the sub-parameter is set to 1, and the value OFF means that the bit is set to 0.Generally, it is displayed on the configuration window of an ADD command but not displayed on the configuration window of a MOD/RMV/DSP/LST command.Recommended ValueParameter values recommended for different scenariosImpactParameter impact scopeParameter RelationshipRelationship with other parameters. For example, to use this parameter, you need to set related switches and parameters.AccessWhether this parameter is Read & Write or Read Only. If a parameter is not dynamic and is read only, it can be set only when the MO is created and cannot be modified later. To modify the parameter, you must delete the MO first and then create it again.Service Interrupted After ModificationWhether modifying the parameter value interrupts the ongoing services.Interruption ScopePossible interruption scopeInterruption Duration (min)Possible interruption duration (unit: minute)CautionCautions to be taken during the modificationValidation of ModificationHow this parameter takes effect and whether the equipment needs to be restarted after the modification.Impact on Radio Network PerformanceImpact of the parameter on radio network performanceIntroduced in VersionProduct version in which the parameter is introducedAttributeWhether the parameter is a radio parameter, a transport parameter, or an equipment parameter.Initial Value SourceSource for the initial configuration of a parameter. The initial value source can be:Radio planning: The initial value of the parameter comes from radio network planning.Transport planning: The initial value of the parameter comes from transport network planning.Equipment planning: The initial value of the parameter comes from equipment planning.Engineering design: The initial value of the parameter comes from function design.Default/recommended value: The initial value uses the default or recommended value, where the recommended value is preferential. The default/recommended value can be used in most scenarios and adjusted for a specific scenario.Not involved: The initial value of the parameter is not required.

Parameter ListMOParameter IDParameter NameNEMML CommandMeaningIsKeyMandatoryDynamic AttributeFeature IDFeature NameValue TypeGUI Value RangeEnumeration Number/BitUnitActual Value RangeDefault ValueRecommended ValueImpactParameter RelationshipAccessService Interrupted After ModificationInterruption ScopeInterruption Duration (min)CautionValidation of ModificationImpact on Radio Network PerformanceIntroduced in Version...AttributeInitial Value Setting SourceALDDEVICENODevice No.eNodeBDLD ALDSWDSP ALDVERRST ALDIndicates the device number of the ALD.YESYESNoLOFD-001024Remote Electrical Tilt ControlInterval values0~29Not involvedNone0~29NoneNoneALDThe device number of the ALD must be unique. That is, DeviceNo of the RET and TMA MOs must be unique.Read OnlyNot involvedNot involvedNot involvedNot involvedNot involvedNoneV100R001C00EquipmentEquipment PlanningALDRtmVendorCodeActual vendor codeeNodeBNoneIndicates the vendor code of the device in the scanning result.NONOYesLOFD-001024Remote Electrical Tilt ControlCharacter string0~2 charactersNot involvedNone0~2 charactersNoneNoneALDNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedALDRtmDeviceSerialNoActual device serial No.eNodeBDSP ALDVERIndicates the serial number of the device in the scanning result.NONOYesLOFD-001024Remote Electrical Tilt ControlCharacter string0~17 charactersNot involvedNone0~17 charactersNoneNoneALDNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedALDDEVICENAMEDevice nameeNodeBDSP ALDVERIndicates the device name of the ALD, which is optional but must be unique. The device name identifies the ALD. The format of the name is site_sector_device type_network type.NONONoLOFD-001024Remote Electrical Tilt ControlCharacter string0~49 charactersNot involvedNone0~49 charactersNULLNoneALDThe device name of an ALD must differ from other ALDs. The device names of RET and TMA must also differ from other RETs and TMAs.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningALDCTRLPORTCNControl port cabinet No.eNodeBDLD ALDSWDLD RETCFGDATADSP ALDVERRST ALDSCN ALDIndicates the cabinet number of the RRU that controls the ALD.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~62Not involvedNone0~6200ALDNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningALDCTRLPORTSRNControl port subrack No.eNodeBDLD ALDSWDLD RETCFGDATADSP ALDVERRST ALDSCN ALDIndicates the subrack number of the RRU that controls the ALD.NOYESNoLOFD-001024Remote Electrical Tilt ControlInterval values4~5,60~254Not involvedNone4~5,60~254NoneNoneALDNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningALDCTRLPORTSNControl port slot No.eNodeBDLD ALDSWDLD RETCFGDATADSP ALDVERRST ALDSCN ALDIndicates the slot number of the RRU that controls the ALD.NOYESNoLOFD-001024Remote Electrical Tilt ControlInterval values0~5Not involvedNone0~5NoneNoneALDNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningALDProtocolVersionProtocol versioneNodeBDSP ALDVERIndicates the actual protocol version of the ALD. You can run the SCN ALD command to query the parameter.NONOYesLOFD-001024Remote Electrical Tilt ControlEnumeration valuesAISG1.1, AISG2.0, 3GPP, UNKNOWNAISG1.1~1, AISG2.0~2, 3GPP~3, UNKNOWN~255NoneAISG1.1, AISG2.0, 3GPP, UNKNOWNNoneNoneALDNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedALDRtmTotalSubunitNumActual subunit numbereNodeBNoneIndicates the total number of ALD subunits.NONOYesLOFD-001024Remote Electrical Tilt ControlInterval values0~8Not involvedNone0~8NoneNoneALDNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedALDHardwareVersionHardware versioneNodeBDSP ALDVERIndicates the version information about the ALD hardware.NONOYesLOFD-001024Remote Electrical Tilt ControlCharacter string0~19 charactersNot involvedNone0~19 charactersNoneNoneALDNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedALDSoftwareVersionSoftware versioneNodeBDSP ALDVERIndicates the version information about the ALD software.NONOYesLOFD-001024Remote Electrical Tilt ControlCharacter string0~127 charactersNot involvedNone0~127 charactersNoneNoneALDNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedALDDeviceModelDevice modeleNodeBDSP ALDVERIndicates the device model of the ALD.NONOYesLOFD-001024Remote Electrical Tilt ControlCharacter string0~19 charactersNot involvedNone0~19 charactersNoneNoneALDNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedALDDeviceTypeDevice typeeNodeBDSP ALDVERSCN ALDIndicates the device type of the ALD.NONOYesLOFD-001024Remote Electrical Tilt ControlEnumeration valuesSINGLE_RET, STMA, MULTI_RETSINGLE_RET~1, STMA~2, MULTI_RET~17NoneSINGLE_RET, STMA, MULTI_RETNoneNoneALDNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedRETVENDORCODEVendor codeeNodeBADD RETMOD RETLST RETSCN ALDIndicates the vendor code of the ALD.NOYESNoLOFD-001024Remote Electrical Tilt ControlCharacter string0~2 charactersNot involvedNone0~2 charactersNoneNoneRETVendorCode and SerialNo of an ALD must differ from other ALDs.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRETSERIALNOSerial No.eNodeBADD RETMOD RETLST RETSCN ALDIndicates the serial number of the ALD.NOYESNoLOFD-001024Remote Electrical Tilt ControlCharacter string0~17 charactersNot involvedNone0~17 charactersNoneNoneRETVendorCode and SerialNo of an ALD must differ from other ALDs.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRETRETTYPERET typeeNodeBADD RETMOD RETLST RETIndicates the RET antenna type, which can be SINGLE_RET or MULTI_RET.NOYESNoLOFD-001024Remote Electrical Tilt ControlEnumeration valuesSINGLE_RET, MULTI_RETSINGLE_RET~1, MULTI_RET~17NoneSINGLE_RET, MULTI_RETNoneNoneRET1. When the RET antenna type is SINGLE_RET, the number of RET subunits is 1.2. When the RET antenna type is MULTI_RET, enter the number of the configured RET subunits.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRETPOLARTYPEPolar typeeNodeBADD RETMOD RETLST RETIndicates the polarization type of the RET antenna, which can be SINGLE or DUAL.NOYESNoLOFD-001024Remote Electrical Tilt ControlEnumeration valuesSINGLE, DUALSINGLE~1, DUAL~2NoneSINGLE, DUALNoneNoneRETOnly one physical port is required for a uni-polarization single antenna.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRETSCENARIOAntenna scenarioeNodeBADD RETMOD RETLST RETIndicates the connection scenario of the RET antenna. This parameter must be set in accordance with physical connections. In daisy chain scenarios, the correct vendor code and device serial number must be set. The value of this parameter must be consistent with the actual connection scenario. Otherwise, the eNodeB fails to communicate with the ALD. If the vendor code or the device serial number is not specified, the system returns a message indicating that the parameter is invalid. To query the vendor code and device serial number, run the SCN ALD command.NOYESNoLOFD-001024Remote Electrical Tilt ControlEnumeration valuesREGULAR, DAISY_CHAINREGULAR~1, DAISY_CHAIN~2NoneREGULAR, DAISY_CHAINNoneNoneRET1. In a daisy chain scenario, VENDORCODE and SERIALNO must be specified.2. The controlling RRU or RFU MO in a daisy chain scenario cannot control RET MOs in regular scenarios. The controlling RRU or RFU MO in a regular scenario cannot control RET MOs in other regular scenarios either.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRETSUBUNITNUMRET subunit numbereNodeBADD RETMOD RETLST RETIndicates the number of subunits configured for the RET antenna. If this parameter is changed, subunits are added or removed in ascending or descending order by subunit number. The number of RET subunits that can be configured for an RET antenna varies depending on the RET antenna type. A maximum of eight RET subunits can be configured for an RET antenna of the MULTI_RET type. The number of RET subunits for an RET antenna of the SINGLE_RET type is 1 by default.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values1~8Not involvedNone1~81NoneRETWhen the RET antenna type is SINGLE_RET, the number of RET subunits is 1. If the RET antenna type is MULTI_RET, enter the number of configured RET subunits.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRETDEVICENODevice No.eNodeBADD RETDSP RETLST RETMOD RETRMV RETIndicates the device number of the ALD.YESYESNoLOFD-001024Remote Electrical Tilt ControlInterval values0~29Not involvedNone0~29NoneNoneRETThe device number of the ALD must be unique. That is, DeviceNo of the RET and TMA MOs must be unique.Read OnlyNot involvedNot involvedNot involvedNot involvedNot involvedNoneV100R001C00EquipmentEquipment PlanningRETRtmVendorCodeActual vendor codeeNodeBDSP RETIndicates the vendor code of the device in the scanning result.NONOYesLOFD-001024Remote Electrical Tilt ControlCharacter string0~2 charactersNot involvedNone0~2 charactersNoneNoneRETNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedRETRtmDeviceSerialNoActual device serial No.eNodeBDSP RETIndicates the serial number of the device in the scanning result.NONOYesLOFD-001024Remote Electrical Tilt ControlCharacter string0~17 charactersNot involvedNone0~17 charactersNoneNoneRETNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedRETDEVICENAMEDevice nameeNodeBADD RETMOD RETLST RETIndicates the device name of the ALD, which is optional but must be unique. The device name identifies the ALD. The format of the name is site_sector_device type_network type.NONONoLOFD-001024Remote Electrical Tilt ControlCharacter string0~49 charactersNot involvedNone0~49 charactersNULLNoneRETThe device name of an ALD must differ from other ALDs. The device names of RET and TMA must also differ from other RETs and TMAs.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRETCTRLPORTCNControl port cabinet No.eNodeBADD RETMOD RETLST RETIndicates the cabinet number of the RRU that controls the ALD.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~62Not involvedNone0~6200RETNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRETCTRLPORTSRNControl port subrack No.eNodeBADD RETMOD RETLST RETIndicates the subrack number of the RRU that controls the ALD.NOYESNoLOFD-001024Remote Electrical Tilt ControlInterval values4~5,60~254Not involvedNone4~5,60~254NoneNoneRETNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRETCTRLPORTSNControl port slot No.eNodeBADD RETMOD RETLST RETIndicates the slot number of the RRU that controls the ALD.NOYESNoLOFD-001024Remote Electrical Tilt ControlInterval values0~5Not involvedNone0~5NoneNoneRETNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRETProtocolVersionProtocol versioneNodeBDSP RETIndicates the actual protocol version of the ALD. You can run the SCN ALD command to query the parameter.NONOYesLOFD-001024Remote Electrical Tilt ControlEnumeration valuesAISG1.1, AISG2.0, 3GPP, UNKNOWNAISG1.1~1, AISG2.0~2, 3GPP~3, UNKNOWN~255NoneAISG1.1, AISG2.0, 3GPP, UNKNOWNNoneNoneRETNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedRETRtmTotalSubunitNumActual subunit numbereNodeBDSP RETIndicates the total number of ALD subunits.NONOYesLOFD-001024Remote Electrical Tilt ControlInterval values0~8Not involvedNone0~8NoneNoneRETNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedRETHardwareVersionHardware versioneNodeBNoneIndicates the version information about the ALD hardware.NONOYesLOFD-001024Remote Electrical Tilt ControlCharacter string0~19 charactersNot involvedNone0~19 charactersNoneNoneRETNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedRETSoftwareVersionSoftware versioneNodeBNoneIndicates the version information about the ALD software.NONOYesLOFD-001024Remote Electrical Tilt ControlCharacter string0~127 charactersNot involvedNone0~127 charactersNoneNoneRETNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedRETDeviceModelDevice modeleNodeBNoneIndicates the device model of the ALD.NONOYesLOFD-001024Remote Electrical Tilt ControlCharacter string0~19 charactersNot involvedNone0~19 charactersNoneNoneRETNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedRETDeviceTypeDevice typeeNodeBNoneIndicates the device type of the ALD.NONOYesLOFD-001024Remote Electrical Tilt ControlEnumeration valuesSINGLE_RET, STMA, MULTI_RETSINGLE_RET~1, STMA~2, MULTI_RET~17NoneSINGLE_RET, STMA, MULTI_RETNoneNoneRETNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedRetDeviceDataDEVICENODevice No.eNodeBDSP RETDEVICEDATALST RETDEVICEDATAMOD RETDEVICEDATAIndicates the device number of the RET.YESYESNoLOFD-001024Remote Electrical Tilt ControlInterval values0~29Not involvedNone0~29NoneNoneRetDeviceDataNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentEquipment PlanningRetDeviceDataSUBUNITNOSubunit No.eNodeBDSP RETDEVICEDATALST RETDEVICEDATAMOD RETDEVICEDATAIndicates the number of the RET subunit.YESYESNoLOFD-001024Remote Electrical Tilt ControlInterval values1~8Not involvedNone1~8NoneNoneRetDeviceDataNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentEquipment PlanningRetDeviceDataBEARINGAntenna bearingeNodeBMOD RETDEVICEDATALST RETDEVICEDATAIndicates the antenna azimuth.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~359Not involveddegree0~3590NoneRetDeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentRadio PlanningRetDeviceDataMODELNOAntenna model numbereNodeBMOD RETDEVICEDATALST RETDEVICEDATAIndicates the model of the RET antenna module.NONONoLOFD-001024Remote Electrical Tilt ControlCharacter string0~31 charactersNot involvedNone0~31 charactersNULLNoneRetDeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRetDeviceDataBSIDBase station IdeNodeBMOD RETDEVICEDATALST RETDEVICEDATAIndicates the base station ID.NONONoLOFD-001024Remote Electrical Tilt ControlCharacter string0~31 charactersNot involvedNone0~31 charactersNULLNoneRetDeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRetDeviceDataBEAMWIDTH1Beamwidth1eNodeBMOD RETDEVICEDATALST RETDEVICEDATAIndicates the beamwidth of band 1. Beamwidth defines the capability of an antenna to transmit RF signals. It also defines the width of the antenna pattern.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~359Not involveddegree0~3590NoneRetDeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedRetDeviceDataBEAMWIDTH2Beamwidth2eNodeBMOD RETDEVICEDATALST RETDEVICEDATAIndicates the beamwidth of band 2. Beamwidth defines the capability of an antenna to transmit RF signals. It also defines the width of the antenna pattern.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~359Not involveddegree0~3590NoneRetDeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedRetDeviceDataBEAMWIDTH3Beamwidth3eNodeBMOD RETDEVICEDATALST RETDEVICEDATAIndicates the beamwidth of band 3. Beamwidth defines the capability of an antenna to transmit RF signals. It also defines the width of the antenna pattern.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~359Not involveddegree0~3590NoneRetDeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedRetDeviceDataBEAMWIDTH4Beamwidth4eNodeBMOD RETDEVICEDATALST RETDEVICEDATAIndicates the beamwidth of band 4. Beamwidth defines the capability of an antenna to transmit RF signals. It also defines the width of the antenna pattern.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~359Not involveddegree0~3590NoneRetDeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedRetDeviceDataGAIN1Gain1eNodeBMOD RETDEVICEDATALST RETDEVICEDATAIndicates the antenna gain of band 1. Antenna gain is defined as the intensity of an antenna in a given direction to the intensity that would be produced by a hypothetical ideal antenna that radiates equally in all directions (isotropically) and has no losses.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~255Not involved0.1dBi0~25.5, step:0.10NoneRetDeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedRetDeviceDataGAIN2Gain2eNodeBMOD RETDEVICEDATALST RETDEVICEDATAIndicates the antenna gain of band 2. Antenna gain is defined as the intensity of an antenna in a given direction to the intensity that would be produced by a hypothetical ideal antenna that radiates equally in all directions (isotropically) and has no losses.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~255Not involved0.1dBi0~25.5, step:0.10NoneRetDeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedRetDeviceDataGAIN3Gain3eNodeBMOD RETDEVICEDATALST RETDEVICEDATAIndicates the antenna gain of band 3. Antenna gain is defined as the intensity of an antenna in a given direction to the intensity that would be produced by a hypothetical ideal antenna that radiates equally in all directions (isotropically) and has no losses.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~255Not involved0.1dBi0~25.5, step:0.10NoneRetDeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedRetDeviceDataGAIN4Gain4eNodeBMOD RETDEVICEDATALST RETDEVICEDATAIndicates the antenna gain of band 4. Antenna gain is defined as the intensity of an antenna in a given direction to the intensity that would be produced by a hypothetical ideal antenna that radiates equally in all directions (isotropically) and has no losses.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~255Not involved0.1dBi0~25.5, step:0.10NoneRetDeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedRetDeviceDataDATEInstalled dateeNodeBMOD RETDEVICEDATALST RETDEVICEDATAIndicates the installation date in the format of YYYYMM.NONONoLOFD-001024Remote Electrical Tilt ControlCharacter string0~6 charactersNot involvedNone0~6 charactersNULLNoneRetDeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRetDeviceDataTILTInstalled mechanical tilteNodeBMOD RETDEVICEDATALST RETDEVICEDATAIndicates the mechanical tilt of the installed RET.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values-100~300Not involved0.1degree-10~30, step:0.10NoneRetDeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentRadio PlanningRetDeviceDataINSTALLERIDInstaller IdeNodeBMOD RETDEVICEDATALST RETDEVICEDATAIndicates the ID of the installer.NONONoLOFD-001024Remote Electrical Tilt ControlCharacter string0~5 charactersNot involvedNone0~5 charactersNULLNoneRetDeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRetDeviceDataBAND1Band1eNodeBMOD RETDEVICEDATALST RETDEVICEDATAIndicates supported band 1.NONONoLOFD-001024Remote Electrical Tilt ControlEnumeration valuesUNUSED, Band800(800MHz), Band900(900MHz), Band1500(1500MHz), Band1800(1800MHz), Band1900(1900MHz), Band2100(2100MHz), Band2600(2600MHz)UNUSED~0, Band800~1, Band900~2, Band1500~3, Band1800~4, Band1900~5, Band2100~6, Band2600~7MHzUNUSED, Band800, Band900, Band1500, Band1800, Band1900, Band2100, Band2600UNUSEDNoneRetDeviceDataThe four frequency bands supported by the RET antenna cannot be repeated.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedRetDeviceDataBAND2Band2eNodeBMOD RETDEVICEDATALST RETDEVICEDATAIndicates supported band 2.NONONoLOFD-001024Remote Electrical Tilt ControlEnumeration valuesUNUSED, Band800(800MHz), Band900(900MHz), Band1500(1500MHz), Band1800(1800MHz), Band1900(1900MHz), Band2100(2100MHz), Band2600(2600MHz)UNUSED~0, Band800~1, Band900~2, Band1500~3, Band1800~4, Band1900~5, Band2100~6, Band2600~7MHzUNUSED, Band800, Band900, Band1500, Band1800, Band1900, Band2100, Band2600UNUSEDNoneRetDeviceDataThe four frequency bands supported by the RET antenna cannot be repeated.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedRetDeviceDataBAND3Band3eNodeBMOD RETDEVICEDATALST RETDEVICEDATAIndicates supported band 3.NONONoLOFD-001024Remote Electrical Tilt ControlEnumeration valuesUNUSED, Band800(800MHz), Band900(900MHz), Band1500(1500MHz), Band1800(1800MHz), Band1900(1900MHz), Band2100(2100MHz), Band2600(2600MHz)UNUSED~0, Band800~1, Band900~2, Band1500~3, Band1800~4, Band1900~5, Band2100~6, Band2600~7MHzUNUSED, Band800, Band900, Band1500, Band1800, Band1900, Band2100, Band2600UNUSEDNoneRetDeviceDataThe four frequency bands supported by the RET antenna cannot be repeated.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedRetDeviceDataBAND4Band4eNodeBMOD RETDEVICEDATALST RETDEVICEDATAIndicates supported band 4.NONONoLOFD-001024Remote Electrical Tilt ControlEnumeration valuesUNUSED, Band800(800MHz), Band900(900MHz), Band1500(1500MHz), Band1800(1800MHz), Band1900(1900MHz), Band2100(2100MHz), Band2600(2600MHz)UNUSED~0, Band800~1, Band900~2, Band1500~3, Band1800~4, Band1900~5, Band2100~6, Band2600~7MHzUNUSED, Band800, Band900, Band1500, Band1800, Band1900, Band2100, Band2600UNUSEDNoneRetDeviceDataThe four frequency bands supported by the RET antenna cannot be repeated.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedRetDeviceDataSECTORIDSector IdeNodeBMOD RETDEVICEDATALST RETDEVICEDATAIndicates the sector ID.NONONoLOFD-001024Remote Electrical Tilt ControlCharacter string0~31 charactersNot involvedNone0~31 charactersNULLNoneRetDeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRetDeviceDataSERIALNOSerial No.eNodeBMOD RETDEVICEDATALST RETDEVICEDATAIndicates the serial number of the ALD.NONONoLOFD-001024Remote Electrical Tilt ControlCharacter string0~17 charactersNot involvedNone0~17 charactersNULLNoneRetDeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRetDeviceDataMaxTiltMax tilteNodeBDSP RETDEVICEDATAIndicates the maximum tilt supported by the RET subunit.NONOYesLOFD-001024Remote Electrical Tilt ControlInterval values-1800~1800Not involved0.1degree-180~180, step:0.1NoneNoneRetDeviceDataNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedRetDeviceDataMinTiltMin tilteNodeBDSP RETDEVICEDATAIndicates the minimum tilt supported by the RET subunit.NONOYesLOFD-001024Remote Electrical Tilt ControlInterval values-1800~1800Not involved0.1degree-180~180, step:0.1NoneNoneRetDeviceDataNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedRetPortCNCabinet No.eNodeBDSP RETPORTLST RETPORTMOD RETPORTIndicates the cabinet number of the RRU where the RET port is located.YESYESNoLOFD-001024Remote Electrical Tilt ControlInterval values0Not involvedNone0NoneNoneRetPortNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedRetPortSRNSubrack No.eNodeBDSP RETPORTLST RETPORTMOD RETPORTIndicates the subrack number of the RRU where the RET port is located.YESYESNoLOFD-001024Remote Electrical Tilt ControlInterval values60~254Not involvedNone60~254NoneNoneRetPortNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedRetPortSNSlot No.eNodeBDSP RETPORTLST RETPORTMOD RETPORTIndicates the slot number of the RRU where the RET port is located.YESYESNoLOFD-001024Remote Electrical Tilt ControlInterval values0Not involvedNone0NoneNoneRetPortNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedRetPortPNPort No.eNodeBDSP RETPORTLST RETPORTMOD RETPORTIndicates the number of the RET port on the RRU.YESYESNoLOFD-001024Remote Electrical Tilt ControlEnumeration valuesRET_PORTRET_PORT~2NoneRET_PORTNoneNoneRetPortNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedRetPortTHRESHOLDTYPECurrent alarm thresholdeNodeBMOD RETPORTLST RETPORTIndicates the type of the ALD current alarm threshold. When ALDPwrSwitch is set to ON, the current alarm threshold of the port should be specified. Different ALD system types should be selected according to different ALD types and connection methods. They are described as follows:For RET (multi-wire cable mode) only: undercurrent alarm occur threshold: 10 mA; undercurrent alarm clear threshold: 15 mA; overcurrent alarm occur threshold: 150 mA; overcurrent alarm clear threshold: 120 mA.If the previously listed threshold cannot meet the requirements, you can choose to customize the threshold according to the actual device type. The customized threshold should meet the following requirements: Undercurrent alarm occur threshold < Undercurrent alarm clear threshold < Overcurrent alarm clear threshold < Overcurrent alarm occur thresholdNONONoLOFD-001024Remote Electrical Tilt ControlEnumeration valuesUER_SELF_DEFINE, RET_ONLY_MULTICOREUER_SELF_DEFINE~0, RET_ONLY_MULTICORE~4NoneUER_SELF_DEFINE, RET_ONLY_MULTICOREUER_SELF_DEFINEAccording to the ALD typeRetPortNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedRetPortPWRSWITCHALD power switcheNodeBMOD RETPORTLST RETPORTIndicates the state of the ALD power supply switch. When an ALD needs power supply, set the ALD power supply switch to ON.NONONoLOFD-001024Remote Electrical Tilt ControlEnumeration valuesON, OFFON~0, OFF~1NoneON, OFFOFFIf an ALD needs power supply, set the ALD power supply switch to ON. In other cases, set the ALD power supply switch to OFF.RetPortThe RetPort MO and R0A port of the AntennaPort MO of an RRU MO cannot be enabled at the same time.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedIf the ALD power supply switch is OFF, the running of the ALD may be affected.The parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRetPortOCTHDOvercurrent alarm clear thresholdeNodeBMOD RETPORTLST RETPORTIndicates the overcurrent alarm clear threshold. When the ALD current value is less than this threshold, the overcurrent alarm is cleared.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values10~3500Not involvedmA10~3500155For RET (multi-wire cable mode) only: 120 mARetPort1. OverCurrAlmClrThreshld must be greater than UnderCurrAlmClrThreshld.2. OverCurrAlmClrThreshld must be smaller than OverCurrAlmOccThreshld.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedRetPortOOTHDOvercurrent alarm occur thresholdeNodeBMOD RETPORTLST RETPORTIndicates the overcurrent alarm generating threshold. When the ALD current value is greater than this threshold, an overcurrent alarm is reported.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values10~3500Not involvedmA10~3500185For RET (multi-wire cable mode) only: 150 mARetPortOverCurrAlmOccThreshld must be greater than OverCurrAlmClrThreshld.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedRetPortUCTHDUndercurrent alarm clear thresholdeNodeBMOD RETPORTLST RETPORTIndicates the undercurrent alarm clear threshold. When the ALD current value is greater than this threshold, the undercurrent alarm is cleared.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values10~3500Not involvedmA10~350060For RET (multi-wire cable mode) only: 15 mARetPort1. UnderCurrAlmClrThreshld must be greater than UnderCurrAlmOccThreshld.2. UnderCurrAlmClrThreshld must be smaller than OverCurrAlmClrThreshld.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedRetPortUOTHDUndercurrent alarm occur thresholdeNodeBMOD RETPORTLST RETPORTIndicates the undercurrent alarm generating threshold. When the ALD current value is smaller than this threshold, an undercurrent alarm is reported.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values10~3500Not involvedmA10~350040For RET (multi-wire cable mode) only: 10 mARetPortUnderCurrAlmOccThreshld must be smaller than UnderCurrAlmClrThreshld.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedRetPortALDCurrValueALD current valueeNodeBDSP RETPORTIndicates the observed current of the ALD.NONOYesLOFD-001024Remote Electrical Tilt ControlInterval values0~3500Not involvedmA0~3500NoneNoneRetPortNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedRetPortALDRtmPwrSwitchALD actual power switcheNodeBDSP RETPORTIndicates the actual state of the ALD power supply switch. When an overcurrent or undercurrent alarm is reported, the actual state may differ from the configured state.NONOYesLOFD-001024Remote Electrical Tilt ControlEnumeration valuesON, OFFON~0, OFF~1NoneON, OFFNoneNoneRetPortValue range: ON~0, OFF~1When this parameter is 0, the power switch is turned on.When this parameter is 1, the power switch is turned off.Read OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedRETSubUnitDEVICENODevice No.eNodeBCLB RETDLD RETCFGDATADSP RETSUBUNITLST RETSUBUNITMOD RETSUBUNITMOD RETTILTIndicates the device number of the RET.YESYESNoLOFD-001024Remote Electrical Tilt ControlInterval values0~29Not involvedNone0~29NoneNoneRETSubUnitNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentEquipment PlanningRETSubUnitSUBUNITNOSubunit No.eNodeBCLB RETDLD RETCFGDATADSP RETSUBUNITLST RETSUBUNITMOD RETSUBUNITIndicates the number of the RET subunit.YESYESNoLOFD-001024Remote Electrical Tilt ControlInterval values1~8Not involvedNone1~8NoneNoneRETSubUnitNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentEquipment PlanningRETSubUnitStatusOnline statuseNodeBDSP RETSUBUNITIndicates the online status of the subunit.NONOYesLOFD-001024Remote Electrical Tilt ControlEnumeration valuesAVAILABLE, UNAVAILABLE, BREAKLINKAVAILABLE~0, UNAVAILABLE~1, BREAKLINK~2NoneAVAILABLE, UNAVAILABLE, BREAKLINKNoneNoneRETSubUnitNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedRETSubUnitRtmTiltActual tilteNodeBDSP RETSUBUNITIndicates the actual tilt of the RET subunit.NONOYesLOFD-001024Remote Electrical Tilt ControlInterval values-100~300Not involved0.1degree-10~30, step:0.1NoneNoneRETSubUnitNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedRETSubUnitSECTORNOSector IdeNodeBCLB RETDLD ALDSWDLD RETCFGDATADSP RETSUBUNITIndicates the sector ID of the RET subunit.NONOYesLOFD-001024Remote Electrical Tilt ControlInterval values0~11Not involvedNone0~11NoneNoneRETSubUnitNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedRETSubUnitCONNCN1Connect port 1 cabinet No.eNodeBMOD RETSUBUNITLST RETSUBUNITIndicates the cabinet number of the RRU to which the antenna is connected to through antenna port 1.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~62Not involvedNone0~6200RETSubUnitIn the non-MIMO-mutual-aid scenarios, the connecting ports 1 and 2 must be different antenna ports on the same RRU.In the MIMO-mutual-aid scenarios, the connecting ports 1 and 2 must be different antenna ports on different RRUs.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRETSubUnitCONNSRN1Connect port 1 subrack No.eNodeBMOD RETSUBUNITLST RETSUBUNITIndicates the subrack number of the RRU to which the antenna port 1 of the ALD is connected. When the subrack number of the port to which the RET subunit is connected is 255, the port is not connected.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values4~5,60~255Not involvedNone4~5,60~255255NoneRETSubUnit1.When the subrack number of the port is 255, the port is not connected.2. In the non-MIMO-mutual-aid scenarios, the connecting ports 1 and 2 must be different antenna ports on the same RRU. In the MIMO-mutual-aid scenarios, the connecting ports 1 and 2 can be different antenna ports on different RRUs.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRETSubUnitCONNSN1Connect port 1 slot No.eNodeBMOD RETSUBUNITLST RETSUBUNITIndicates the slot number of the RRU to which the antenna is connected to through antenna port 1.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~5Not involvedNone0~50NoneRETSubUnitIn the non-MIMO-mutual-aid scenarios, the connecting ports 1 and 2 must be different antenna ports on the same RRU.In the MIMO-mutual-aid scenarios, the connecting ports 1 and 2 can be different antenna ports on different RRUs.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRETSubUnitCONNPN1Connect port 1 port No.eNodeBMOD RETSUBUNITLST RETSUBUNITIndicates the port number of the RRU to which the antenna is connected to through antenna port 1.NONONoLOFD-001024Remote Electrical Tilt ControlEnumeration valuesR0A, R0B, R0C, R0D, R0E, R0F, R0G, R0HR0A~0, R0B~1, R0C~2, R0D~3, R0E~4, R0F~5, R0G~6, R0H~7NoneR0A, R0B, R0C, R0D, R0E, R0F, R0G, R0HR0ANoneRETSubUnitIn the non-MIMO-mutual-aid scenarios, the connecting ports 1 and 2 must be different antenna ports on the same RRU.In the MIMO-mutual-aid scenarios, the connecting ports 1 and 2 can be different antenna ports on different RRUs.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRETSubUnitCONNCN2Connect port 2 cabinet No.eNodeBMOD RETSUBUNITLST RETSUBUNITIndicates the cabinet number of the RRU to which the antenna is connected through the antenna port 2. This parameter is valid to the dual-polarized antenna.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~62Not involvedNone0~6200RETSubUnitIn the non-MIMO-mutual-aid scenarios, the connecting ports 1 and 2 must be different antenna ports on the same RRU.In the MIMO-mutual-aid scenarios, the connecting ports 1 and 2 can be different antenna ports on different RRUs.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRETSubUnitCONNSRN2Connect port 2 subrack No.eNodeBMOD RETSUBUNITLST RETSUBUNITIndicates the subrack number of the RRU to which the antenna port 2 of the ALD is connected. This parameter is valid for the dual-polarized antenna. When the subrack number of the port to which the RET subunit is connected is 255, the port is not connected.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values4~5,60~255Not involvedNone4~5,60~255255NoneRETSubUnit1.When the subrack number of the port is 255, the port is not connected.2.In the non-MIMO-mutual-aid scenarios, the connecting ports 1 and 2 must be different antenna ports on the same RRU.In the MIMO-mutual-aid scenarios, the connecting ports 1 and 2 can be different antenna ports on different RRUs.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRETSubUnitCONNSN2Connect port 2 slot No.eNodeBMOD RETSUBUNITLST RETSUBUNITIndicates the slot number of the RRU to which the antenna is connected through antenna port 2. This parameter is valid when a dual-polarized antenna is used.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~5Not involvedNone0~50NoneRETSubUnitIn the non-MIMO-mutual-aid scenarios, the connecting ports 1 and 2 must be different antenna ports on the same RRU.In the MIMO-mutual-aid scenarios, the connecting ports 1 and 2 can be different antenna ports on different RRUs.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRETSubUnitCONNPN2Connect port 2 port No.eNodeBMOD RETSUBUNITLST RETSUBUNITIndicates the port number of the RRU to which the antenna is connected through antenna port 2. This parameter is valid when a dual-polarized antenna is used.NONONoLOFD-001024Remote Electrical Tilt ControlEnumeration valuesR0A, R0B, R0C, R0D, R0E, R0F, R0G, R0HR0A~0, R0B~1, R0C~2, R0D~3, R0E~4, R0F~5, R0G~6, R0H~7NoneR0A, R0B, R0C, R0D, R0E, R0F, R0G, R0HR0BNoneRETSubUnitIn the non-MIMO-mutual-aid scenarios, the connecting ports 1 and 2 must be different antenna ports on the same RRU.In the MIMO-mutual-aid scenarios, the connecting ports 1 and 2 can be different antenna ports on different RRUs.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningRETSubUnitTILTTilteNodeBMOD RETSUBUNITMOD RETTILTLST RETSUBUNITIndicates the antenna tilt of the RET subunit.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values-100~300Not involved0.1degree-10~30, step:0.10NoneRETSubUnitNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentRadio PlanningRETSubUnitAERTilt alarm error rangeeNodeBMOD RETSUBUNITLST RETSUBUNITIndicates the alarm error range of the tilt of the RET subunit. When the tilt error reaches the threshold, the alarm is reported.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~10Not involved0.1degree0~1, step:0.155RETSubUnitNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedTMASUBUNITNUMTMA subunit numbereNodeBADD TMAMOD TMALST TMAIndicates the number of configured TMA subunits.NOYESNoLOFD-001024Remote Electrical Tilt ControlInterval values1~2Not involvedNone1~2NoneNoneTMANoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningTMADEVICENODevice No.eNodeBADD TMADSP TMALST TMAMOD TMARMV TMAIndicates the device number of the ALD.YESYESNoLOFD-001024Remote Electrical Tilt ControlInterval values0~29Not involvedNone0~29NoneNoneTMAThe device number of the ALD must be unique. That is, DeviceNo of the RET and TMA MOs must be unique.Read OnlyNot involvedNot involvedNot involvedNot involvedNot involvedNoneV100R001C00EquipmentEquipment PlanningTMARtmVendorCodeActual vendor codeeNodeBDSP TMAIndicates the vendor code of the device in the scanning result.NONOYesLOFD-001024Remote Electrical Tilt ControlCharacter string0~2 charactersNot involvedNone0~2 charactersNoneNoneTMANoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedTMARtmDeviceSerialNoActual device serial No.eNodeBDSP TMAIndicates the serial number of the device in the scanning result.NONOYesLOFD-001024Remote Electrical Tilt ControlCharacter string0~17 charactersNot involvedNone0~17 charactersNoneNoneTMANoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedTMADEVICENAMEDevice nameeNodeBADD TMAMOD TMALST TMAIndicates the device name of the ALD, which is optional but must be unique. The device name identifies the ALD. The format of the name is site_sector_device type_network type.NONONoLOFD-001024Remote Electrical Tilt ControlCharacter string0~49 charactersNot involvedNone0~49 charactersNULLNoneTMAThe device name of an ALD must differ from other ALDs. The device names of RET and TMA must also differ from other RETs and TMAs.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningTMACTRLPORTCNControl port cabinet No.eNodeBADD TMAMOD TMALST TMAIndicates the cabinet number of the RRU that controls the ALD.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~62Not involvedNone0~6200TMANoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningTMACTRLPORTSRNControl port subrack No.eNodeBADD TMAMOD TMALST TMAIndicates the subrack number of the RRU that controls the ALD.NOYESNoLOFD-001024Remote Electrical Tilt ControlInterval values4~5,60~254Not involvedNone4~5,60~254NoneNoneTMANoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningTMACTRLPORTSNControl port slot No.eNodeBADD TMAMOD TMALST TMAIndicates the slot number of the RRU that controls the ALD.NOYESNoLOFD-001024Remote Electrical Tilt ControlInterval values0~5Not involvedNone0~5NoneNoneTMANoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningTMAProtocolVersionProtocol versioneNodeBNoneIndicates the actual protocol version of the ALD. You can run the SCN ALD command to query the parameter.NONOYesLOFD-001024Remote Electrical Tilt ControlEnumeration valuesAISG1.1, AISG2.0, 3GPP, UNKNOWNAISG1.1~1, AISG2.0~2, 3GPP~3, UNKNOWN~255NoneAISG1.1, AISG2.0, 3GPP, UNKNOWNNoneNoneTMANoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedTMARtmTotalSubunitNumActual subunit numbereNodeBDSP TMAIndicates the total number of ALD subunits.NONOYesLOFD-001024Remote Electrical Tilt ControlInterval values0~8Not involvedNone0~8NoneNoneTMANoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedTMAHardwareVersionHardware versioneNodeBNoneIndicates the version information about the ALD hardware.NONOYesLOFD-001024Remote Electrical Tilt ControlCharacter string0~19 charactersNot involvedNone0~19 charactersNoneNoneTMANoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedTMASoftwareVersionSoftware versioneNodeBNoneIndicates the version information about the ALD software.NONOYesLOFD-001024Remote Electrical Tilt ControlCharacter string0~127 charactersNot involvedNone0~127 charactersNoneNoneTMANoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedTMADeviceModelDevice modeleNodeBNoneIndicates the device model of the ALD.NONOYesLOFD-001024Remote Electrical Tilt ControlCharacter string0~19 charactersNot involvedNone0~19 charactersNoneNoneTMANoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedTMADeviceTypeDevice typeeNodeBNoneIndicates the device type of the ALD.NONOYesLOFD-001024Remote Electrical Tilt ControlEnumeration valuesSINGLE_RET, STMA, MULTI_RETSINGLE_RET~1, STMA~2, MULTI_RET~17NoneSINGLE_RET, STMA, MULTI_RETNoneNoneTMANoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedTMADeviceDataDEVICENODevice No.eNodeBDSP TMADEVICEDATALST TMADEVICEDATAMOD TMADEVICEDATAIndicates the device number of the TMA.YESYESNoLOFD-001024Remote Electrical Tilt ControlInterval values0~29Not involvedNone0~29NoneNoneTMADeviceDataNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentEquipment PlanningTMADeviceDataSUBUNITNOSubunit No.eNodeBDSP TMADEVICEDATALST TMADEVICEDATAMOD TMADEVICEDATAIndicates the number of the TMA subunit.YESYESNoLOFD-001024Remote Electrical Tilt ControlInterval values1~2Not involvedNone1~2NoneNoneTMADeviceDataNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentEquipment PlanningTMADeviceDataBEARINGAntenna bearingeNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates the antenna azimuth.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~359Not involveddegree0~3590NoneTMADeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedTMADeviceDataBSIDBase station IdeNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates the base station ID.NONONoLOFD-001024Remote Electrical Tilt ControlCharacter string0~31 charactersNot involvedNone0~31 charactersNULLNoneTMADeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningTMADeviceDataBEAMWIDTH1Beamwidth1eNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates the beamwidth of band 1. Beamwidth defines the capability of an antenna to transmit RF signals. It also defines the width of the antenna pattern.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~359Not involveddegree0~3590NoneTMADeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedTMADeviceDataBEAMWIDTH2Beamwidth2eNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates the beamwidth of band 2. Beamwidth defines the capability of an antenna to transmit RF signals. It also defines the width of the antenna pattern.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~359Not involveddegree0~3590NoneTMADeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedTMADeviceDataBEAMWIDTH3Beamwidth3eNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates the beamwidth of band 3. Beamwidth defines the capability of an antenna to transmit RF signals. It also defines the width of the antenna pattern.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~359Not involveddegree0~3590NoneTMADeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedTMADeviceDataBEAMWIDTH4Beamwidth4eNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates the beamwidth of band 4. Beamwidth defines the capability of an antenna to transmit RF signals. It also defines the width of the antenna pattern.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~359Not involveddegree0~3590NoneTMADeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedTMADeviceDataGAIN1Gain1eNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates the antenna gain of band 1. Antenna gain is defined as the intensity of an antenna in a given direction to the intensity that would be produced by a hypothetical ideal antenna that radiates equally in all directions (isotropically) and has no losses.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~255Not involved0.1dBi0~25.5, step:0.10NoneTMADeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedTMADeviceDataGAIN2Gain2eNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates the antenna gain of band 2. Antenna gain is defined as the intensity of an antenna in a given direction to the intensity that would be produced by a hypothetical ideal antenna that radiates equally in all directions (isotropically) and has no losses.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~255Not involved0.1dBi0~25.5, step:0.10NoneTMADeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedTMADeviceDataGAIN3Gain3eNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates the antenna gain of band 3. Antenna gain is defined as the intensity of an antenna in a given direction to the intensity that would be produced by a hypothetical ideal antenna that radiates equally in all directions (isotropically) and has no losses.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~255Not involved0.1dBi0~25.5, step:0.10NoneTMADeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedTMADeviceDataGAIN4Gain4eNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates the antenna gain of band 4. Antenna gain is defined as the intensity of an antenna in a given direction to the intensity that would be produced by a hypothetical ideal antenna that radiates equally in all directions (isotropically) and has no losses.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~255Not involved0.1dBi0~25.5, step:0.10NoneTMADeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedTMADeviceDataDATEInstalled dateeNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates the installation date.NONONoLOFD-001024Remote Electrical Tilt ControlCharacter string0~6 charactersNot involvedNone0~6 charactersNULLNoneTMADeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningTMADeviceDataTILTInstalled mechanical tilteNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates the mechanical tilt of the installation.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values-100~300Not involved0.1degree-10~30, step:0.10NoneTMADeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedTMADeviceDataINSTALLERIDInstaller IdeNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates the ID of the installer.NONONoLOFD-001024Remote Electrical Tilt ControlCharacter string0~5 charactersNot involvedNone0~5 charactersNULLNoneTMADeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningTMADeviceDataBAND1Band1eNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates supported band 1.NONONoLOFD-001024Remote Electrical Tilt ControlEnumeration valuesUNUSED, Band800(800MHz), Band900(900MHz), Band1500(1500MHz), Band1800(1800MHz), Band1900(1900MHz), Band2100(2100MHz), Band2600(2600MHz)UNUSED~0, Band800~1, Band900~2, Band1500~3, Band1800~4, Band1900~5, Band2100~6, Band2600~7MHzUNUSED, Band800, Band900, Band1500, Band1800, Band1900, Band2100, Band2600UNUSEDNoneTMADeviceDataThe four frequency bands supported by the TMA cannot be repeated.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedTMADeviceDataBAND2Band2eNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates supported band 2.NONONoLOFD-001024Remote Electrical Tilt ControlEnumeration valuesUNUSED, Band800(800MHz), Band900(900MHz), Band1500(1500MHz), Band1800(1800MHz), Band1900(1900MHz), Band2100(2100MHz), Band2600(2600MHz)UNUSED~0, Band800~1, Band900~2, Band1500~3, Band1800~4, Band1900~5, Band2100~6, Band2600~7MHzUNUSED, Band800, Band900, Band1500, Band1800, Band1900, Band2100, Band2600UNUSEDNoneTMADeviceDataThe four frequency bands supported by the TMA cannot be repeated.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedTMADeviceDataBAND3Band3eNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates supported band 3.NONONoLOFD-001024Remote Electrical Tilt ControlEnumeration valuesUNUSED, Band800(800MHz), Band900(900MHz), Band1500(1500MHz), Band1800(1800MHz), Band1900(1900MHz), Band2100(2100MHz), Band2600(2600MHz)UNUSED~0, Band800~1, Band900~2, Band1500~3, Band1800~4, Band1900~5, Band2100~6, Band2600~7MHzUNUSED, Band800, Band900, Band1500, Band1800, Band1900, Band2100, Band2600UNUSEDNoneTMADeviceDataThe four frequency bands supported by the TMA cannot be repeated.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedTMADeviceDataBAND4Band4eNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates supported band 4.NONONoLOFD-001024Remote Electrical Tilt ControlEnumeration valuesUNUSED, Band800(800MHz), Band900(900MHz), Band1500(1500MHz), Band1800(1800MHz), Band1900(1900MHz), Band2100(2100MHz), Band2600(2600MHz)UNUSED~0, Band800~1, Band900~2, Band1500~3, Band1800~4, Band1900~5, Band2100~6, Band2600~7MHzUNUSED, Band800, Band900, Band1500, Band1800, Band1900, Band2100, Band2600UNUSEDNoneTMADeviceDataThe four frequency bands supported by the TMA cannot be repeated.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedTMADeviceDataSECTORIDSector IdeNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates the sector ID.NONONoLOFD-001024Remote Electrical Tilt ControlCharacter string0~31 charactersNot involvedNone0~31 charactersNULLNoneTMADeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningTMADeviceDataSERIALNOSerial No.eNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates the serial number of the TMA.NONONoLOFD-001024Remote Electrical Tilt ControlCharacter string0~17 charactersNot involvedNone0~17 charactersNULLNoneTMADeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningTMADeviceDataMODELNOConnect antenna model numbereNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates the model of the RET antenna connected to the TMA.NONONoLOFD-001024Remote Electrical Tilt ControlCharacter string0~31 charactersNot involvedNone0~31 charactersNULLNoneTMADeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningTMADeviceDataGAINRESLUTIONGain resolutioneNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates the gain resolution.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~255Not involved0.25dB0~63.75, step:0.250NoneTMADeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedTMADeviceDataSUBUNITTYPESubunit typeeNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates the type of the TMA subunit. It indicates whether the VSWR measurement and the bypass mode are supported.NONONoLOFD-001024Remote Electrical Tilt ControlEnumeration valuesUNSUPPORT, SUPPORT_PASSBY, SUPPORT_VSWR, VSWR/PASSBYUNSUPPORT~0, SUPPORT_PASSBY~1, SUPPORT_VSWR~2, VSWR/PASSBY~3NoneUNSUPPORT, SUPPORT_PASSBY, SUPPORT_VSWR, VSWR/PASSBYUNSUPPORTNoneTMADeviceDataNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedTMADeviceDataRXMAXFBReceived max frequency bandeNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates the maximum RX frequency bandwidth of the subunit.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~65535Not involved100KHz0~6553500, step:1000NoneTMADeviceDataTmaRxMaxFreBand must not be less than TmaRxMinFreBand.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedTMADeviceDataTXMAXFBTransmit max frequency bandeNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates the maximum transmit frequency band of the subunit.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~65535Not involved100KHz0~6553500, step:1000NoneTMADeviceDataTmaTxMaxFreBand must not be less than TmaTxMinFreBand.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedTMADeviceDataRXMINFBReceived min frequency bandeNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates the minimum RX frequency bandwidth of the subunit.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~65535Not involved100KHz0~6553500, step:1000NoneTMADeviceDataTmaRxMinFreBand must not be more than TmaRxMaxFreBand.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedTMADeviceDataTXMINFBTransmit min frequency bandeNodeBMOD TMADEVICEDATALST TMADEVICEDATAIndicates the minimum TX frequency bandwidth of the subunit.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~65535Not involved100KHz0~6553500, step:1000NoneTMADeviceDataTmaTxMinFreBand must not be more than TmaTxMaxFreBand.Read & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedTMADeviceDataMaxSupportedGainMax supported gaineNodeBDSP TMADEVICEDATAIndicates the maximum supported gain.NONOYesLOFD-001024Remote Electrical Tilt ControlInterval values0~255Not involved0.25dB0~63.75, step:0.25NoneNoneTMADeviceDataNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedTMADeviceDataMinSupportedGainMin supported gaineNodeBDSP TMADEVICEDATAIndicates the minimum supported gain.NONOYesLOFD-001024Remote Electrical Tilt ControlInterval values0~255Not involved0.25dB0~63.75, step:0.25NoneNoneTMADeviceDataNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedTMASubUnitDEVICENODevice No.eNodeBDSP TMASUBUNITLST TMASUBUNITMOD TMASUBUNITIndicates the device number of the TMA.YESYESNoLOFD-001024Remote Electrical Tilt ControlInterval values0~29Not involvedNone0~29NoneNoneTMASubUnitNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentEquipment PlanningTMASubUnitSUBUNITNOSubunit No.eNodeBDSP TMASUBUNITLST TMASUBUNITMOD TMASUBUNITIndicates the number of the TMA subunit.YESYESNoLOFD-001024Remote Electrical Tilt ControlInterval values1~2Not involvedNone1~2NoneNoneTMASubUnitNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentEquipment PlanningTMASubUnitRtmSectorIdActual sector IdeNodeBDSP TMASUBUNITIndicates the sector ID of the TMA subunit.NONOYesLOFD-001024Remote Electrical Tilt ControlInterval values0~11Not involvedNone0~11NoneNoneTMASubUnitNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedTMASubUnitRtmGainActual gaineNodeBDSP TMASUBUNITIndicates the actual gain of the TMA subunit.NONOYesLOFD-001024Remote Electrical Tilt ControlInterval values0~255Not involved0.25dB0~63.75, step:0.25NoneNoneTMASubUnitNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedTMASubUnitRtmModeActual modeeNodeBDSP TMASUBUNITIndicates the actual working mode of the TMA subunit.NONOYesLOFD-001024Remote Electrical Tilt ControlEnumeration valuesNORMAL, BYPASSNORMAL~0, BYPASS~1NoneNORMAL, BYPASSNoneNoneTMASubUnitNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedTMASubUnitStatusOnline statuseNodeBDSP TMASUBUNITIndicates the online status of the TMA subunit.NONOYesLOFD-001024Remote Electrical Tilt ControlEnumeration valuesAVAILABLE, UNAVAILABLE, BREAKLINKAVAILABLE~0, UNAVAILABLE~1, BREAKLINK~2NoneAVAILABLE, UNAVAILABLE, BREAKLINKNoneNoneTMASubUnitNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedTMASubUnitCONNPNConnect port No.eNodeBMOD TMASUBUNITLST TMASUBUNITIndicates the number of the antenna port to which the TMA subunit is connected.NOYESNoLOFD-001024Remote Electrical Tilt ControlEnumeration valuesR0A, R0B, R0C, R0D, R0E, R0F, R0G, R0HR0A~0, R0B~1, R0C~2, R0D~3, R0E~4, R0F~5, R0G~6, R0H~7NoneR0A, R0B, R0C, R0D, R0E, R0F, R0G, R0HNoneNoneTMASubUnitNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningTMASubUnitCONNCNConnect port cabinet No.eNodeBMOD TMASUBUNITLST TMASUBUNITIndicates the cabinet number of the RRU or RFU of the antenna port to which the subunit is connected.NOYESNoLOFD-001024Remote Electrical Tilt ControlInterval values0~62Not involvedNone0~62None0TMASubUnitNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningTMASubUnitCONNSNConnect port slot No.eNodeBMOD TMASUBUNITLST TMASUBUNITIndicates the slot number of the RRU or RFU that provides the port to which the subunit is connected.NOYESNoLOFD-001024Remote Electrical Tilt ControlInterval values0~5Not involvedNone0~5NoneNoneTMASubUnitNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningTMASubUnitCONNSRNConnect port subrack No.eNodeBMOD TMASUBUNITLST TMASUBUNITIndicates the subrack number of the RRU or RFU of the antenna port to which the subunit is connected.NOYESNoLOFD-001024Remote Electrical Tilt ControlInterval values4~5,60~254Not involvedNone4~5,60~254NoneNoneTMASubUnitNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentEquipment PlanningTMASubUnitGAINGaineNodeBMOD TMASUBUNITLST TMASUBUNITIndicates the gain of the TMA subunit.NONONoLOFD-001024Remote Electrical Tilt ControlInterval values0~255Not involved0.25dB0~63.75, step:0.25048TMASubUnitNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentRadio PlanningTMASubUnitMODEModeeNodeBMOD TMASUBUNITLST TMASUBUNITIndicates the working mode of the TMA subunit.NONONoLOFD-001024Remote Electrical Tilt ControlEnumeration valuesNORMAL, BYPASSNORMAL~0, BYPASS~1NoneNORMAL, BYPASSNORMALNORMALTMASubUnitNoneRead & WriteNo (And no impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.When this parameter is set to NORMAL, the TMA can work properly to improve the signal-to-noise ratio and sensitivity of the eNodeB. When this parameter is set to BYPASS, the TMA does not amplify any uplink signal.V100R001C00EquipmentDefault/RecommendedBBPCNCabinet No.eNodeBDSP BBPLST BBPMOD BBPIndicates the cabinet number of the baseband processing board.YESNONoNoneNoneInterval values0~7Not involvedNone0~700BBPNoneRead OnlyNot involvedNot involvedNot involvedNot involvedNot involvedNoneV100R001C00EquipmentEquipment PlanningBBPSRNSubrack No.eNodeBDSP BBPLST BBPMOD BBPIndicates the subrack number of the baseband processing board.YESNONoNoneNoneInterval values0~1Not involvedNone0~100BBPNoneRead OnlyNot involvedNot involvedNot involvedNot involvedNot involvedNoneV100R001C00EquipmentEquipment PlanningBBPSNSlot No.eNodeBDSP BBPLST BBPMOD BBPIndicates the slot number of the LBBP.YESYESNoNoneNoneInterval values0~5Not involvedNone0~5None1,2,3BBPNoneRead OnlyNot involvedNot involvedNot involvedNot involvedNot involvedNoneV100R001C00EquipmentEquipment PlanningBBPADMSTATEAdministrative StateeNodeBMOD BBPDSP BRDLST BBPIndicates the administrative state of the board. The administrative state of the board can be blocked, unblocked, or shutting down. For details, see ITU-T X.731.NONONoNoneNoneEnumeration valuesLocked, Unlocked, ShutingdownLocked~0, Unlocked~1, Shutingdown~2NoneLocked, Unlocked, ShutingdownUnlockedUnlockedBBPNoneRead & WriteYesThe cells carried on the BBP are unavailable.Till unblocking is performedNoneThe parameter modification has no impact on the equipment.NoneV100R001C00EquipmentDefault/RecommendedBBPWMModeeNodeBADD BRDMOD BBPLST BBPIndicates the duplex mode in which the LBBP operates. The value TDD_ENHANCE indicates the time division duplex (TDD) mode integrated with the beamforming (BF) function. The BF function provides the data transmission service in transmission mode 7 or 8 defined in the protocol. For details, see 3GPP TS 36.213.NOYESNoNoneNoneEnumeration valuesRAT_FDD, RAT_TDD, TDD_ENHANCERAT_FDD~0, RAT_TDD~1, TDD_ENHANCE~2NoneRAT_FDD, RAT_TDD, TDD_ENHANCENoneNoneBBP1. When Mode in the BBP MO is set to TDD_ENHANCE, the RRUCHAIN MO does not support the ring topology, namely that TopoType cannot be RING in this case.When Mode in the BBP MO is set to TDD, the RRUCHAIN MO does not support the hot backup ring topology. That is, when TopoType is set to RING, BackupMode cannot be HOT.2. When Mode in the BBP MO is set to TDD or TDD_ENHANCE, the RRU MO does not support a multi-level chain, namely that InsertPos in the RRU MO cannot be greater than 0 in this case.Read & WriteYesThe cells carried on the boards.< 2NoneThe parameter modification takes effect after the board is automatically reset.NoneV100R001C00EquipmentEquipment PlanningBBPPhyBrdTypePhysical board typeeNodeBDSP BBPIndicates the physical type of the LBBP.NONOYesNoneNoneEnumeration valuesLBBPb(LBBPb), LBBPc(LBBPc)LBBPb~0, LBBPc~1NoneLBBPb, LBBPcNoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R002C00EquipmentNot involvedBBPAlarmStateAlarm StatuseNodeBNoneIndicates the alarm status. For details about the definition of Alarm Status, see ITU-T X.731.NONOYesLBFD-004006Fault ManagementEnumeration valuesAlarm_0(Normal), Alarm_1(Warning), Alarm_2(Minor), Alarm_3(Minor), Alarm_4(Major), Alarm_5(Major), Alarm_6(Major), Alarm_7(Major), Alarm_8(Critical), Alarm_9(Critical), Alarm_10(Critical), Alarm_11(Critical), Alarm_12(Critical), Alarm_13(Critical), Alarm_14(Critical), Alarm_15(Critical)Alarm_0~0, Alarm_1~1, Alarm_2~2, Alarm_3~3, Alarm_4~4, Alarm_5~5, Alarm_6~6, Alarm_7~7, Alarm_8~8, Alarm_9~9, Alarm_10~10, Alarm_11~11, Alarm_12~12, Alarm_13~13, Alarm_14~14, Alarm_15~15NoneAlarm_0, Alarm_1, Alarm_2, Alarm_3, Alarm_4, Alarm_5, Alarm_6, Alarm_7, Alarm_8, Alarm_9, Alarm_10, Alarm_11, Alarm_12, Alarm_13, Alarm_14, Alarm_15NoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R003C00EquipmentNot involvedBBPOpStateOperational StateeNodeBNoneIndicates the operational state of the board, which can be set to Enabled or Disabled. Enabled indicates that services can be carried on the board. Disabled indicates that no service can be carried on the board.NONOYesNoneNoneEnumeration valuesEnabled(Enabled), Disabled(Disabled)Enabled~0, Disabled~1NoneEnabled, DisabledNoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R003C00EquipmentNot involvedBBPAvailabilityStatusAvailability StatuseNodeBNoneIndicates the physical operation status of the board, which can be Uninstalled, Starting up, Normal, Inconsistent, Unconfigured, Power off, Fault, Communication lost, In test, or the combination of various states. For example, if a board is not configured and fails to communicate with the main control and transmission board, the physical operation status of the board is Unconfigured, Communication lost.NONOYesLBFD-004012Environment MonitorEnumeration valuesAvail_0(Normal), Avail_1(Fault), Avail_20(In test), Avail_21(Fault, In test), Avail_500(Starting up), Avail_501(Starting up, Fault), Avail_504(Unconfigured), Avail_508(Inconsistent), Avail_509(Inconsistent, Fault), Avail_520(Starting up,In test), Avail_521(Starting up, Fault, In test), Avail_524(Unconfigured,In test), Avail_528(Inconsistent,In test), Avail_529(Inconsistent, Fault, In test), Avail_800(Communication lost), Avail_801(Fault, Communication lost), Avail_820(Communication lost, In test), Avail_821(Fault, Communication lost, In test), Avail_c10(Power off), Avail_c11(Power off, Fault), Avail_c12(Uninstalled), Avail_c13(Uninstalled, Fault), Avail_c14(Unconfigured, Power off), Avail_c30(Power off,In test), Avail_c31(Power off, Fault, In test), Avail_c32(Uninstalled,In test), Avail_c33(Uninstalled, Fault, In test), Avail_c34(Unconfigured, Power off, In test), Avail_d00(Communication lost), Avail_d01(Starting up, Fault, Communication lost), Avail_d04(Unconfigured, Communication lost), Avail_d08(Inconsistent, Communication lost), Avail_d09(Inconsistent, Fault, Communication lost), Avail_d20(Starting up, Communication lost,In test), Avail_d21(Starting up, Fault, Communication lost, In test), Avail_d24(Unconfigured, Communication lost, In test), Avail_d28(Inconsistent, Communication lost, In test), Avail_d29(Inconsistent, Fault, Communication lost, In test)Avail_0~0, Avail_1~1, Avail_20~32, Avail_21~33, Avail_500~1280, Avail_501~1281, Avail_504~1284, Avail_508~1288, Avail_509~1289, Avail_520~1312, Avail_521~1313, Avail_524~1316, Avail_528~1320, Avail_529~1321, Avail_800~2048, Avail_801~2049, Avail_820~2080, Avail_821~2081, Avail_c10~3088, Avail_c11~3089, Avail_c12~3090, Avail_c13~3091, Avail_c14~3092, Avail_c30~3120, Avail_c31~3121, Avail_c32~3122, Avail_c33~3123, Avail_c34~3124, Avail_d00~3328, Avail_d01~3329, Avail_d04~3332, Avail_d08~3336, Avail_d09~3337, Avail_d20~3360, Avail_d21~3361, Avail_d24~3364, Avail_d28~3368, Avail_d29~3369NoneAvail_0, Avail_1, Avail_20, Avail_21, Avail_500, Avail_501, Avail_504, Avail_508, Avail_509, Avail_520, Avail_521, Avail_524, Avail_528, Avail_529, Avail_800, Avail_801, Avail_820, Avail_821, Avail_c10, Avail_c11, Avail_c12, Avail_c13, Avail_c14, Avail_c30, Avail_c31, Avail_c32, Avail_c33, Avail_c34, Avail_d00, Avail_d01, Avail_d04, Avail_d08, Avail_d09, Avail_d20, Avail_d21, Avail_d24, Avail_d28, Avail_d29NoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R003C00EquipmentNot involvedBBPElabelElectronic LabeleNodeBNoneIndicates the E-label, a text file with a maximum of 2 KB. It is used to record the manufacturing information about equipment such as the board, sub-board, or optical module.NONOYesNoneNoneCharacter string0~2047 charactersNot involvedNone0~2047 charactersNoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R001C00EquipmentNot involvedBBPBoardTypeTypeeNodeBNoneIndicates the type of the board.NONOYesNoneNoneCharacter string0~31 charactersNot involvedNone0~31 charactersNoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R003C00EquipmentNot involvedBBPBoardSerialSerial NumbereNodeBNoneIndicates the bar code of the board or the cabinet.NONOYesNoneNoneCharacter string0~31 charactersNot involvedNone0~31 charactersNoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R003C00EquipmentNot involvedBBPBoardDescDescriptioneNodeBNoneIndicates the description about the services and functions provided by the board or the cabinet.NONOYesNoneNoneCharacter string0~259 charactersNot involvedNone0~259 charactersNoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R003C00EquipmentNot involvedBBPBoardManuDate of ManufactureeNodeBNoneIndicates the manufacturing date of the board or the cabinet.NONOYesNoneNoneCharacter string0~11 charactersNot involvedNone0~11 charactersNoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R003C00EquipmentNot involvedBBPBoardVendorVendoreNodeBNoneIndicates the manufacturer of the board or the cabinet.NONOYesNoneNoneCharacter string0~23 charactersNot involvedNone0~23 charactersNoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R003C00EquipmentNot involvedBBPBoardIssueIssue NumbereNodeBNoneIndicates the issue number of the board.NONOYesNoneNoneCharacter string0~19 charactersNot involvedNone0~19 charactersNoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R003C00EquipmentNot involvedBBPRuTypeConfig TypeeNodeBNoneIndicates the type of a board.NONOYesNoneNoneEnumeration valuesLMPT(LMPT), LBBP(LBBP), FAN(FAN), UPEU(UPEU), UTRP(UTRP), USCU(USCU), UEIU(UEIU)LMPT~1, LBBP~2, FAN~3, UPEU~4, UTRP~11, USCU~12, UEIU~13NoneLMPT, LBBP, FAN, UPEU, UTRP, USCU, UEIUNoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R003C00EquipmentNot involvedBBPObjectNumberObject NumbereNodeBNoneIndicates the object number of a board.NONOYesNoneNoneInterval values0~4294967295Not involvedNone0~4294967295NoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R003C00EquipmentNot involvedBBPObjectTypeObject TypeeNodeBNoneIndicates the object type of a board, which is CPU or DSP.NONOYesNoneNoneEnumeration valuesCPU(CPU), DSP(DSP)CPU~0, DSP~1NoneCPU, DSPNoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R003C00EquipmentNot involvedBBPBoardTemperatureBoard TemperatureeNodeBNoneIndicates the temperature of a board.NONOYesNoneNoneInterval values-2147483648~2147483647Not involveddegree Celsius-2147483648~2147483647NoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R003C00EquipmentNot involvedBBPHPATemperatureHPA TemperatureeNodeBNoneIndicates the temperature of the power amplifier.NONOYesNoneNoneInterval values-2147483648~2147483647Not involveddegree Celsius-2147483648~2147483647NoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R003C00EquipmentNot involvedBBPOperateResultOperate ResulteNodeBNoneIndicates the result of the operation.NONOYesNoneNoneCharacter string0~255 charactersNot involvedNone0~255 charactersNoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R003C00EquipmentNot involvedBBPServiceTypeService TypeeNodeBNoneIndicates the service type of the CPU or DSP of the board. The service types of the DSP consist of uplink and downlink services. The service types of the CPU consist of Master and Slave.NONOYesNoneNoneEnumeration valuesMaster(Master), NDD(NDD), NCD(NCD), NDC(NDC), NEC(NEC), EUL(EUL), EDL(EDL)Master~0, NDD~1, NCD~2, NDC~3, NEC~4, EUL~5, EDL~6NoneMaster, NDD, NCD, NDC, NEC, EUL, EDLNoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R003C00EquipmentNot involvedBBPDEVTYPEDEVTYPEeNodeBNoneIndicates the type of the device.NONOYesNoneNoneEnumeration valuesCABINET(CABINET), SUBRACK(SUBRACK), BOARD(BOARD), SUBBOARD(SUBBOARD), SFP(SFP)CABINET~0, SUBRACK~1, BOARD~2, SUBBOARD~3, SFP~4NoneCABINET, SUBRACK, BOARD, SUBBOARD, SFPNoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R003C00EquipmentNot involvedBBPNeNameOffice NameeNodeBNoneIndicates the Office name of the BS.NONOYesNoneNoneCharacter string0~63 charactersNot involvedNone0~63 charactersNoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R002C00EquipmentNot involvedBBPSoftVerSoftware VersioneNodeBNoneIndicates the software version of the board.NONOYesNoneNoneCharacter string0~63 charactersNot involvedNone0~63 charactersNoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R002C00EquipmentNot involvedBBPHardVerHardware VersioneNodeBNoneIndicates the hardware version of the board.NONOYesNoneNoneCharacter string0~63 charactersNot involvedNone0~63 charactersNoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R002C00EquipmentNot involvedBBPBtrmVerBootRom VersioneNodeBNoneIndicates the BootROM version of the board.NONOYesNoneNoneCharacter string0~63 charactersNot involvedNone0~63 charactersNoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R002C00EquipmentNot involvedBBPHwTestTimeTest TimeeNodeBNoneIndicates the test time.NONOYesNoneNoneCharacter string1~39 charactersNot involvedNone1~39 charactersNoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R002C00EquipmentNot involvedBBPTestResultTest ResulteNodeBNoneIndicates the test result.NONOYesNoneNoneEnumeration valuesNormal(Normal), Fault(Fault), Timeout(Timeout), NULL(NULL)Normal~0, Fault~1, Timeout~2, NULL~4294967295NoneNormal, Fault, Timeout, NULLNoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R002C00EquipmentNot involvedBBPDLFREQDownlink FrequencyeNodeBNoneThe downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [10562-10838] Offset: 0 Special Frequencies Channel Number: none Offset: 0 Band2: Common Frequencies Channel Number: [9662-9938] Offset: 0 Special Frequencies Channel Number: (412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687) Offset: 1850.1 Band3: Common Frequencies Channel Number: [1162-1513] Offset: 1575 Special Frequencies Channel Number: none Offset: 0 Band4: Common Frequencies Channel Number: [1537-1738] Offset: 1805 Special Frequencies Channel Number: (1887, 1912, 1937, 1962, 1987, 2012, 2037, 2062, 2087) Offset: 1735.1 Band5: Common Frequencies Channel Number: [4357-4458] Offset: 0 Special Frequencies Channel Number: (1007, 1012, 1032, 1037, 1062, 1087) Offset: 670.1 Band6: Common Frequencies Channel Number: [4387-4413] Offset: 0 Special Frequencies Channel Number: (1037, 1062) Offset: 670.1 Band7: Common Frequencies Channel Number: [2237-2563] Offset: 2175 Special Frequencies Channel Number: (2587, 2612, 2637, 2662, 2687, 2712, 2737, 2762, 2787, 2812, 2837, 2862, 2887, 2912) Offset: 2105.1 Band8: Common Frequencies Channel Number: [2937-3088] Offset: 340 Special Frequencies Channel Number: none Offset: 0 Band9: Common Frequencies Channel Number: [9237-9387] Offset: 0 Special Frequencies Channel Number: none Offset: 0. The frequency of the local cell must be the same as that of the bearing logical cell.NONOYesNoneNoneInterval values0~65535Not involvedNone0~65535NoneNoneBBPNoneRead OnlyNot involvedNot involvedNot involvedNoneNot involvedNoneV100R002C00EquipmentNot involvedBBPULFREQUplink FrequencyeNodeBNoneThe downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [9612-9888] Offset: 0 Special Frequencies Channel Number: none Offset: 0 Band2: Common Frequencies Channel Number: [9262-9538] Offset: 0 Special Frequencies Channel Number: (12, 37, 62, 87, 112, 137, 162, 187, 212, 23