STRING & MESHINSTALLATION GUIDE
Covers:StringMesh
06/12 v0.2
FLEXIBILITY, SIMPLICITY & INNOVATION IN LIGHTING SOLUTIONS & SERVICES
-
String and Mesh Installation Guide www.traxontechnologies.com 06/12 v0.2 2
C o n t e n t s
1. INTRODUCTION P.3
2. INSTALLATION P.6
2.1 POINTS TO CONSIDER P.6
2.2 PRE-INSTALLATION CHECKS P.7
2.3 ON-SITE INSTALLATION P.9
3. SAFETY AND OPERATION P.13
4. SYSTEM CONFIGURATION P.16
5. CARE AND MAINTENANCE P.21
6. TROUBLESHOOTING P.21
7. TECHNICAL SPECIFICATION P.22
8. WARRANTY STATEMENT P.22
FOR YOUR OWN SAFETY AND THAT OF THE PRODUCT, PLEASE READ THIS INSTALLATION
GUIDE CAREFULLY BEFORE BEGINNING SETUP AND INSTALLATION.
THIS IS A CLASS B PRODUCT. IN A DOMESTIC ENVIRONMENT THIS PRODUCT MAY
CAUSE RADIO INTERFERENCE IN WHICH CASE THE USER MAY BE REqUIRED TO TAkE
ADEqUATE COUNTER MEASURES.
-
String and Mesh Installation Guide www.traxontechnologies.com 06/12 v0.2 3
1. INTRODUCTION
1.1 General String
The Traxon String system accomplishes complex, unconventional media configurations with intelligence and style. Sophisticated, scalable, and semi-transparent, String systems alter and enhance architectural, retail, and hospitality environments adding unexpected character to classic scenarios. Available in full color (RGB), with or without a diffuser dome, String gracefully incorporates graphics, text, and video into various, irregular surfaces, resulting in unordinary media displays never before possible. String is controllable by DMX512 and e:pix/DVI input signals, and Smart Chip technology and intelligent software allow maximum control of even the most intricate media scenarios. Warm White and Cold White options are also available upon request.
Features:Flexible mounting capabilityLow-to-medium resolution media (graphics, text and video animations)Outdoor rating (IP67 - String, IP66 - Pixel Distributor)Smart Chip technologyAuto-addressing
Mesh
Mesh systems reinvent the large-scale media experience. The sophisticated, scalable, semi-transparent LED system elegantly transforms any surface into a brilliant palette for graphics, text, and video animations in full color (RGB). Meshs semi-transparent, durable yet flexible structure, allows it to adapt to many surfaces in various applications, in both indoor and outdoor environments. Its acrylic grid system can also be mounted back-to-back for dual displays, allowing bright graphics to shine, and natural light to pass through without obstructing a view or diminishing an open-area concept. Mesh is controllable by DMX512 and e:pix/DVI input signals, and Smart Chip technology and intelligent software allow maximum control of even the most intricate media scenarios. Warm White and Cold White options are also available upon request.
Features:Flexible mounting capabilityBack-to-back mounting for dual media displaysLow-to-medium resolution media (graphics, text and video animations)Outdoor rating (IP67 - Mesh unit, IP66 - Pixel Distributor)UV resistantSmart Chip technologyAuto-addressing
-
String and Mesh Installation Guide www.traxontechnologies.com 06/12 v0.2 4
1.2 String Dimensions
~310mm/12.20
DO.TA.7014000(with diffuser dome)
DO.SA.7014000
62.5mm/2.46 (pitch) x 31
18.8
0mm
/0.7
4 39mm/1.54
15.2
0mm
/0.6
0
10.5
0mm
/0.4
1
1.50
mm
/0.0
6
10.5
4mm
/0.4
2
20.7
0mm
/0.8
1
7.80
mm
/0.3
1
18.80mm/0.74
12mm/0.47
1.2.1 String Packing Contents
5 x 32-dot Strings
1 x Pixel Distributor 2 x Mounting Brackets and Screwsfor Pixel Distributor
-
String and Mesh Installation Guide www.traxontechnologies.com 06/12 v0.2 5
1.3 Mesh Dimensions
62.5
0mm
/2.4
6
62.5
0mm
/2.4
6
296mm/11.65
62.5
0mm
/2.4
6
31.25mm/1.23
62.5
0mm
/2.4
6 (t
yp.)
62.50mm/2.46
251m
m/9
.88
2007
.95m
m/7
9.05
296mm/11.65
56.50mm/2.22
19.27mm/0.76
62.5
0mm
/2.4
6
62.5
0mm
/2.4
6
296mm/11.65
62.5
0mm
/2.4
6
31.25mm/1.23
62.5
0mm
/2.4
6 (t
yp.)
62.50mm/2.46
251m
m/9
.88
2007
.95m
m/7
9.05
296mm/11.65
56.50mm/2.22
19.27mm/0.76
1.3.1 Mesh Packing Contents
1 x Mesh Unit
1 x Pixel Distributor2 x Mounting Brackets and Screws
for Pixel Distributor
16 x Screws for Back-to-Back Mounting2 x Mounting Wire + Stoppers
-
String and Mesh Installation Guide www.traxontechnologies.com 06/12 v0.2 6
1.4 Pixel Distributor Dimensions
290mm/11.42
321.60mm/12.66
89.80m
m/3.54
99.30m
m/3.91
56.50mm/2.22
77.80mm/3.06
312.50mm/12.30
NOTE: keep a proper connection with cables or end caps with Pixel Distributor to ensure complete sealing from water. Store in an indoor dry environment before installation.
2. INSTALLATION
2.1 Points To ConsiderPlan your installation before mounting the String or Mesh. The following should be considered for a successful installation.
Installation distances and appropriate cable lengths. Please consult your local Traxon office or authorized agent for necessary aid.
The number of Strings or Mesh, Pixel Distributors and appropriate LED Engines.
Any DMX512 controllers to be used with the products.
2.1.1 Installation ChecklistPrepare cables and all necessary accessories.1. Perform functional check of Strings/Mesh.2. Ensure all pre-installation checks laid out below have been followed.3. Mount the Strings or Mesh on-site. If the installation is to be left uncompleted overnight, place all non-4. connected LED Engines and String or Mesh in an indoor environment.
Ensure all the Interconnection Cables, String or Mesh and LED Engines are initially stored in a dry area to guarantee the complete sealing of the system from water before installation.
-
String and Mesh Installation Guide www.traxontechnologies.com 06/12 v0.2 7
2.2 Pre-Installation Checks
2.2.1 Requirements Of Cable BendingTo reduce stress induced on String/Mesh lead cables, please adhere to the Minimum Bending Radius and Non-Bendable Length of 20mm (0.79). The Non-Bendable Length applies to the cable by the connector and the dot (see FIG 1).
FIG 1: Minimum Cable Bending and Non-Bendable Length requirement
(Minimum Bending Radius)20mm/0.79
(Non-Bendable Length)20mm/0.79
(Non-Bendable Length)20mm/0.79
Only bend cable on flat side
NOTE:
NOTE: Water ingress incurred due to cable twisting or excess cable bending will not be under warranty by Traxon Technologies.
2.2.2 Installation SequencePlan for any possible bending of cables (see above). 1. Measure the correct distances to mount the Strings/Mesh units to keep a consistent pitch.2. Secure Pixel Distributors in the desired position and connect Strings. 3. CAUTION: Do not lift Strings by the lead cables as this may damage the cables.For Mesh, secure Pixel Distributors and Mounting Wires in the desired location and connect Mesh units. 4. CAUTION: Do not lift Mesh units by the lead cables as this may damage the cables.Connect Strings/Mesh units as described in the Wiring Diagram (P.17-20).5. Perform functional check on all Strings/Mesh and inspect cables and Mounting Wires for any damage. Check 6. for any abnormalities with the control signal.Report any functional defect found to your nearest Traxon Technologies office. DO NOT attempt to install 7. Strings/Mesh with functional defects on-site.
2.2.3 String Dot Clip (Optional)The String Dot Clip (DO.AC.0001200/DO.AC.0002300) is an optional accessory that can be used to mount the String on an installation surface.
Clips can be mounted on 15mm wide DIN rail (EN 50045, BS 6273).
Ears on clip can be snipped off.
Clip onto DIN rail.
Clips can be dovetailed together.
String 1
String 2
NOTE:Strings need to keep the same orientation
OPTION 1:
Top clip
Screws
Bottom clip
OPTION 2:Using top Clip onlyfor horizontalcable run.
Using top and bottomClips togetherfor horizontalcable run.
OPTION 3: OPTION 4:Using top Clip onlyfor verticalcable run.
Using top and bottomClips togetherfor verticalcable run.
18.3mm/0.7
12.8mm/0.5
22.5mm/0.9
4.3.mm/0.2
32.5mm/1.3
15.1
mm
/0.6
38.0
mm
/1.5
28.0
mm
/1.1
21mm/0.83
15.4mm/0.61
DO.AC.0002300(for dot with diffuser dome)
DO.AC.0001200
DO.AC.0002300 clipon dot with diffuser dome
Clips can be mounted on 15mm wide DIN rail (EN 50045, BS 6273).
Ears on clip can be snipped off.
Clip onto DIN rail.
Clips can be dovetailed together.
String 1
String 2
NOTE:Strings need to keep the same orientation
OPTION 1:
Top clip
Screws
Bottom clip
OPTION 2:Using top Clip onlyfor horizontalcable run.
Using top and bottomClips togetherfor horizontalcable run.
OPTION 3: OPTION 4:Using top Clip onlyfor verticalcable run.
Using top and bottomClips togetherfor verticalcable run.
18.3mm/0.7
12.8mm/0.5
22.5mm/0.9
4.3.mm/0.2
32.5mm/1.3
15.1
mm
/0.6
38.0
mm
/1.5
28.0
mm
/1.1
21mm/0.83
15.4mm/0.61
DO.AC.0002300(for dot with diffuser dome)
DO.AC.0001200
DO.AC.0002300 clipon dot with diffuser dome
-
String and Mesh Installation Guide www.traxontechnologies.com 06/12 v0.2 8
The String Dot Clip can be used in various ways. It can be used to mount horizontally or vertically on an installation surface. Using a combination of Top and Bottom clips, the String can be mounted on a 15mm DIN rail. With a combination of Top and Bottom clips, the dots of the Strings can be dovetailed together for a tighter pixel pitch. The Top clip can also be used independently. See FIG 2 for the different options.
FIG 2: Optional String Clip
Clips can be mounted on 15mm wide DIN rail (EN 50045, BS 6273).
Ears on clip can be snipped off.
Clip onto DIN rail.
Clips can be dovetailed together.
String 1
String 2
NOTE:Strings need to keep the same orientation
OPTION 1:
Top clip
Screws
Bottom clip
OPTION 2:Using top Clip onlyfor horizontalcable run.
Using top and bottomClips togetherfor horizontalcable run.
OPTION 3: OPTION 4:Using top Clip onlyfor verticalcable run.
Using top and bottomClips togetherfor verticalcable run.
18.3mm/0.7
12.8mm/0.5
22.5mm/0.9
4.3.mm/0.2
32.5mm/1.3
15.1
mm
/0.6
38.0
mm
/1.5
28.0
mm
/1.1
21mm/0.83
15.4mm/0.61
DO.AC.0002300(for dot with diffuser dome)
DO.AC.0001200
DO.AC.0002300 clipon dot with diffuser dome
-
String and Mesh Installation Guide www.traxontechnologies.com 06/12 v0.2 9
2.3 On-Site Installation
DO NOT attempt installation in wet or severe weather conditions.
DO NOT leave and expose any Strings/Mesh, Pixel Distributors or LED Engines unconnected under wet/raining or snowing environment.
IP failure induced by stressed/damaged cables during or after installation will not be under warranty by Traxon Technologies.
ALWAYS keep the cables protected from sharp objects and ensure no damage is generated on the cables.
Failure to keep the product within the operating temperature range of 20C to 50C (4F to 122F) and storage temperature range of 40C to 70C (40F to 158F) will void the products warranty.
2.3.1 String InstallationMount Pixel Distributor to installation surface via included mounting brackets. It is recommended to have the 1. connectors facing down. Remove wire clips from Pixel Distributor before attaching to mounting bracket (see FIG 3).
FIG 3: Mounting Pixel Distributor via mounting bracket
Remove wire-clips beforeattaching to bracket.
Mounting multiple units
Mounting on wall with bracket
Connect String lead cable to output connector of Pixel Distributor. 2. NOTE: Once connected, lower the String gently to avoid damaging lead cables. If surface mounting is required for String via the String Dot Clip (see 2.2.3 String Dot Clip, P. 7), secure the dots before connecting the lead cable.
Tightening Torque: 0.48~0.69Nm (5~7kgfcm)
Connect lead cables from Strings to Pixel Distributor and daisy chain Pixel Distributors and power supplies as 3. described in Wiring Diagram (FIGs 9-10, P.17-18).
Any Data and Power cables leading to/from internal power supply units or signal control units have to be installed 4. through conduits/trunking.
Start up each unit and verify correct function.5.
-
String and Mesh Installation Guide www.traxontechnologies.com 06/12 v0.2 10
2.3.2 Mesh InstallationSecure Mounting Wires to installation surface (FIG 4) and mount Pixel Distributor. Thread Mounting Wires 1. through wire clips on either side of Pixel Distributor and tighten (FIG 5). Pixel Distributor can also be installed behind the Mesh grid (see FIG 5).
FIG 4: Preparing the stainless steel Mounting Wires
A
C
B
Slide the wire stopperswith the spacings shown.
Use spirit level to ensuretop wire stoppersare horizontal.
Fix mounting wires withthe distances shown.
For easier mounting, allow wires to hang loose.Bolt wires at bottom after all units are mounted.
Wire stopper slidesfreely in direction A.
Wire stopper can slide in direction C by squeezing plunger into body (B).
1 Prepare the mounting wires.
340mm/26.8
312.5mm/12.3 312.5mm/12.3
125mm/5
125mm/5
155mm/6
FIG 5: Mounting Pixel Distributor to Mounting Wires
2mm/0.08 stainless steel wires
Tighten wire-clipswith 5mm hex key
Mounting multiple units
Pixel Distributor alternative mountingposition behind the Mesh grid.
2mm/0.08 stainless steel wires
Tighten wire-clipswith 5mm hex key
Mounting multiple units
Pixel Distributor alternative mountingposition behind the Mesh grid.
-
String and Mesh Installation Guide www.traxontechnologies.com 06/12 v0.2 11
Assemble the Mesh unit by clipping each grid section together at an angle as shown below. NOTE: Be careful 2. not to damage cables.
Clip the Mesh grids togetherat an angle.
String cable
Attach Mesh units to Mounting Wires and slide wire stoppers into place to secure the units.3.
(C) Slide wire stopper down.(A) Clip Mesh unit onto wire. (B) Rest mesh unit on top stoppers.
Top stoppers
(D) Wire stoppers shown in position.
3 Attach Mesh unit onto mounting wires.
Attach adjacent Mesh unit, align with previous Mesh unit and readjust wire stoppers to secure the units. 4. Repeat until all Mesh units have been mounted.
-
String and Mesh Installation Guide www.traxontechnologies.com 06/12 v0.2 12
If more Mesh units are needed, first clip to the unit above then align with the unit adjacent. Always remember 5. to slide the wire stoppers into place to secure the Mesh units.
X
Y
Mounting additional Mesh units.
X: Attach to above unit first.
Y: Clip wire holders to wire and
rest on adjacent unit.
Slide wire stoppers in place.
Mount Mesh units from left to right.
Mesh units can also be installed back-to-back.6. FIG 6: Mounting Mesh units back to backMounting back-to-back Mesh units.
Use provided screws to
secure the units together.
For single-row back-to-back installations:
1. Remove the wire holders on the back unit.
2. Pre-assemble back-to-back units.
3. Hang the back-to-back units using the
same method as above.
For two-row back-to-back installations:
(Second row Mesh units require customized
lead cable length of 2.5m)
1. Hang Mesh units on one side.
2. Remove the wire holders on the back units.
3. Attach and screw on second row back units.
4. Hide second row lead cables in above units.
5. Attach and screw on first row back units.
Wire holder on
front unit only.
Connect lead cables from Mesh unit to Pixel Distributor and daisy chain Pixel Distributors and power supplies 7. as described in Wiring Diagram (FIGs 11-12, P.19-20).
Any Data and Power cables leading to/from internal power supply units or signal control units have to be installed 8. through conduits/trunking.
Start up each unit and verify correct function.9.
-
String and Mesh Installation Guide www.traxontechnologies.com 06/12 v0.2 13
3. SAFETY AND OPERATION
CAUTION UNPLUG THE POWER SUPPLY FROM THE MAINS POWER BEFORE
CONNECTING ANY CABLES AS THIS CAN DAMAGE THE PRODUCTS.
CAUTION AVOID LOOkING DIRECTLY INTO THE LED LIGHT SOURCE AT CLOSE RANGE
FOR YOUR OWN SAFETY.
ANY PERSONS INSTALLING THIS PRODUCT SHOULD COMPLY WITH LOCAL STANDARDS
AND REGULATIONS AND MUST BE qUALIFIED FOR THE HANDLING OF ELECTRICAL
EqUIPMENT.
Do not attempt to install or use the product until installation instructions and safety labels are fully understood. This product is designed for indoor and outdoor use.
Ensure product operates within the specified temperature range. (Refer to 7. TECHNICAL SPECIFICATION, P.22 for more details.)
Do not attempt to open the product. Not user serviceable.
Do not use the product if any part of it, or the power cables are damaged.
Only use product for specified voltage, do not exceed. (Refer to 7. TECHNICAL SPECIFICATION, P.22 for more details.)
Always maintain connection to ensure waterproofing.
If the product has been subjected to drastic temperature variances, for example, following transportation, do not connect the fixture until it has reached room temperature, as moisture condensation may cause electric shock and product damages.
When installing the products and system power supplies, please ensure they will not be exposed to moisture and extreme heat (and direct sunlight for outdoor products). Besides, keep a clean operating environment for the fixtures and system power supplies.
Please study this Installation Guide thoroughly and check the latest Technical Specification Sheets available from the Traxon website www.traxontechnologies.com before setup.
Any non-compliance of the Installation Guide will void the Traxon warranty.
-
String and Mesh Installation Guide www.traxontechnologies.com 06/12 v0.2 14
3.1 Surge Protection
1. Individual Power Supply Surge Protective Device (SPD)a. UL 1499 Type 1 or Type 2 SPD up to IEEE & ANSI C62.41.2 requirement should be installed in the
main incoming area of the Power Source.b. UL 1499 Type 3 SPD up to IEEE & ANSI C62.41.2 should be installed in individual PSU, individual
LED Engine and individual Data Control Engine to protect the device from abnormal power surge and lightning surge.
2. Product Earthinga. The exposed metal of the product body (eg. wire clips of Pixel Distributor) should be earthed with
resistance less than 1 ohm to the Master Ground according to the ANSI/ESD S6.1 and IEEE standard 142-1982 requirement.
3. Mesh or Mechanical Fixture Earthinga. All the mesh or mechanical fixture (eg. wire stoppers and stainless steel Mounting Wires) to fix the
product should be earthed with less than 1 ohm resistance to Master Ground.4. Shielding of the cable
a. Data Cables or Power Cables of length longer than 10m or Cables to be mounted on Roof Top Area should be shielded to protect the cable from picking up the induced surge from outside environment.
b. The shielding resistance to the Master Ground should be less than 1 ohm.5. System working environment requirement
a. Traxon product complies with IEC 61000 Power Surge and Fast Transient Test requirements.b. Contractor should ensure that the ambient environment should comply with IEC 61000
requirements.6. PSU and Data Control System Rack Earthing
a. All the racks for PSU and Data Control System should be properly earthed with less than 1 ohm resistance to Master Ground.
b. Use short and thick wiring when connecting the equipment to earth ground on the equipment rack to assure safety and prevent noise and leakage current.
It is highly recommended that proper surge protection is implemented into the final installation. See FIG 7 (P. 15) for wiring details.
-
String and Mesh Installation Guide www.traxontechnologies.com 06/12 v0.2 15
FIG 7: Surge Protection Block DiagramIMPORTANT NOTE: This is a general outline including String and Mesh using PSUs and Power/Data Injector Boxes for both indoor and
outdoor applications.
To G
loba
l Ear
th C
onne
ctio
n
AC P
ower
AC P
ower
Sign
alco
ntro
l sys
tem
(But
ler)
Surg
e Pr
otec
tor
Pow
er s
uppl
ym
odul
es(L
ED E
ngin
e Sm
art 1
50W
Indo
or)
TX C
onne
ct S
mar
tIn
door
Pow
er/D
ata
Inje
ctor
Box
Surg
e Pr
otec
tor
Ensu
re p
rope
r ear
thin
g of
the
prod
uct
and
its c
orre
spon
ding
mec
hani
cal f
ixtur
e.
**bl
ocks
in b
lue
( )
are
addi
tiona
l dev
ices
to
sec
ure
equi
pmen
t fro
m s
urge
pow
er.
DIN
Rail
Conn
ect G
loba
l Ear
thto
Pixe
l Dis
tribu
tor
via W
ire C
lips
Conn
ect G
loba
l Ear
thto
sta
inle
ss s
teel
Mou
ntin
g W
ires
TX C
onne
ct S
mar
tOu
tdoo
r Pow
er/D
ata
Inje
ctor
Box
Pow
er s
uppl
y m
odul
es(L
ED E
ngin
e Sm
art 1
50W
Out
door
)
Cabl
e Sh
ield
ing
is re
quire
d. (S
ee it
em 4
a on
P.1
4)
Any
expo
sed
met
al p
arts
(e
g. S
tain
less
ste
el M
ount
ing
Wire
s, D
IN
Rails
) use
d to
fix
the
Strin
g/M
esh
units
m
ust h
ave
a pr
oper
con
nect
ion
to th
e Gl
obal
Ear
th C
onne
ctio
n.
INDO
OROU
TDOO
R
-
String and Mesh Installation Guide www.traxontechnologies.com 06/12 v0.2 16
4. SYSTEM CONFIGURATION
4.1 TYPICAL CONNECTION COMPONENTS
The String and Mesh systems are connected using a daisy chain method via power and data on the same cable and distributed to the dots via the Pixel Distributor. FIG 8 shows some typical components for the String/Mesh Systems.
FIG 8: Connection Components for Monochrome Tube System
LED Engine Smart 150W Outdoor(PS.OA.0010000)
TX Connect Smart OutdoorPower/Data Injector Box(TE.ZI.0000100)
TX Connect Data Indoor/Outdoor Bridge Cable (5m/16.4ft)(DE.AC.0000100)
TX Connect Smart Outdoor Interconnection Cable(TE.IC.0500000) 5m/16.4ft(TE.IC.1500000) 15m/49.2ft(TE.IC.3000000) 30m/98.4ft
Butler160001
Mesh/String Lead Extension Cable (2.5m/8.2ft)(DO.AC.0000700)(Max. 2 extensions per lead)
AC Power Cord(PS.AC.xxxxxxx)
TX Connect Data Cable(DI.IC.xxxxxxx)
TX Connect Smart IndoorPower/Data Injector Box(TI.ZI.0000100)
TX Connect SmartInterconnection Cable(TI.IC.xxxxxxx)
LED Engine Smart 150W Indoor(PS.IC.0010000)
PS.IC.0010000 includes 1x 30cmTX Connect Smart Interconnection Cable
TX Connect Smart IndoorExtension Cable (TI.EC.xxxxxxx)Available in 0.5m, 1m, 3m, 5m, 10m
-
String and Mesh Installation Guide www.traxontechnologies.com 06/12 v0.2 17
FIG 9: String Typical Connection Example Indoors
Part
Num
bers
for I
ND
OO
R S
tring
RG
B S
yste
m
DO
.SA
.701
4000
St
ring
RG
B
PS.IC
.001
0000
LE
D E
ngin
e Sm
art 1
50W
Indo
or
1600
01
But
ler
TI.Z
I.000
0100
TX
Con
nect
Sm
art I
ndoo
r Pow
er/D
ata
Inje
ctor
Box
TE.A
C.0
0001
00
TX C
onne
ct S
mar
t Ind
oor/O
utdo
or B
ridge
Cab
le (5
m/1
6.4f
t)
DO
.AC
.000
0700
M
esh/
Strin
g Le
ad E
xten
sion
Cab
le (2
.5m
/8.2
ft)
DI.I
C.x
xxxx
xx
TX C
onne
ct D
ata
Cab
le
PS.A
C.x
xxxx
xx
AC
Pow
er C
ord
AC
110
V/22
0V 5
0/60
Hz
AC
Pow
er C
ord
(PS.
AC
.xxx
xxxx
)
TX C
onne
ct D
ata
Cab
le(D
I.IC
.xxx
xxxx
)
TX C
onne
ct D
ata
Cab
le(D
I.IC
.xxx
xxxx
)To
add
ition
al u
nit.
TX C
onne
ct S
mar
t Ind
oor
Pow
er/D
ata
Inje
ctor
Box
(TI.Z
I.000
0100
)
TX C
onne
ct S
mar
tIn
terc
onne
ctio
n C
able
(TI.I
C.x
xxxx
xx)
LED
Eng
ine
Smar
t 150
W In
door
(PS.
IC.0
0100
00)
PS.IC
.001
0000
incl
udes
1x
30cm
TX C
onne
ct S
mar
t Int
erco
nnec
tion
Cab
le
TX C
onne
ct S
mar
t Ind
oor/O
utdo
or B
ridge
Cab
le (5
m/1
6.4f
t)(T
E.A
C.0
0001
00)
IND
OO
RO
UTD
OO
R
TX C
onne
ct S
mar
t Ind
oor
Exte
nsio
n C
able
(TI.E
C.x
xxxx
xx)
Ava
ilabl
e in
0.5
m, 1
m, 3
m, 5
m, 1
0m
Exte
nd u
sing
Pixe
l Dis
tribu
tor
(Incl
uded
with
Stri
ng R
GB
)
Strin
g R
GB
(DO
.SA
.701
4000
)
512
DM
X C
hann
els
per o
utpu
t
But
ler
1600
01
CO
NTR
OLL
ERPo
wer
ed v
ia T
X C
onne
ct D
ata
Cab
le
62.5
mm
/2.4
6D
ot P
itch:
5 D
ots
1937
.5m
m/7
6.28
32 D
ots
Mes
h/St
ring
Lead
Ex
tens
ion
Cab
le (2
.5m
/8.2
ft)(D
O.A
C.0
0007
00)
(Max
. 2 e
xten
sion
s pe
r lea
d)
A
B
C
D
A to
B: 1
00 m
eter
s
C
ON
TRO
LLER
to F
IXTU
RE.
C to
D: 3
5 m
eter
s
PO
WER
SU
PPLY
to F
IXTU
RE.
CA
BLI
NG
LEN
GTH
S
CA
UTI
ON
: P
LEA
SE
EN
SU
RE
TH
AT
THE
PO
WE
R IS
SW
ITC
HE
D O
FF W
HE
N T
HE
DA
TA C
AB
LES
AR
E B
EIN
G C
ON
NE
CTE
D.
FAIL
UR
E T
O D
O S
O W
ILL
RE
SU
LT IN
DA
MA
GE
TO
TH
E P
RO
DU
CTS
AN
D V
OID
TH
E P
RO
DU
CT
WA
RR
AN
TY.
-
String and Mesh Installation Guide www.traxontechnologies.com 06/12 v0.2 18
FIG 10: Optional String Outdoor Connection Example
Part
Num
bers
for O
UTD
OO
R S
tring
RG
B S
yste
m
DO
.SA
.701
4000
St
ring
RG
B
PS.O
A.0
0100
00
LED
Eng
ine
Smar
t 150
W O
utdo
or
1600
01
But
ler
TE.Z
I.000
0100
TX
Con
nect
Sm
art O
utdo
or P
ower
/Dat
a In
ject
or B
ox
TE.IC
.xx0
0000
TX
Con
nect
Sm
art O
utdo
or In
terc
onne
ctio
n C
able
DE.
AC
.000
0100
TX
Con
nect
Dat
a In
door
/Out
door
Brid
ge C
able
(5m
/16.
4ft)
DO
.AC
.000
0700
M
esh/
Strin
g Le
ad E
xten
sion
Cab
le (2
.5m
/8.2
ft)
LED
Eng
ine
Smar
t 150
W O
utdo
or(P
S.O
A.0
0100
00)
AC
110
V/22
0V 5
0/60
Hz
TX C
onne
ct S
mar
t Out
door
Pow
er/D
ata
Inje
ctor
Box
(TE.
ZI.0
0001
00)
IND
OO
RO
UTD
OO
R
TX C
onne
ct D
ata
Indo
or/O
utdo
or B
ridge
Cab
le (5
m/1
6.4f
t)(D
E.A
C.0
0001
00)
TX C
onne
ct D
ata
Indo
or/O
utdo
or B
ridge
Cab
le (5
m/1
6.4f
t)(D
E.A
C.0
0001
00)
TX C
onne
ct S
mar
t Out
door
Inte
rcon
nect
ion
Cab
le(T
E.IC
.050
0000
) 5m
/16.
4ft
(TE.
IC.1
5000
00) 1
5m/4
9.2f
t(T
E.IC
.300
0000
) 30m
/98.
4ft
To a
dditi
onal
uni
t.
To c
onst
ruct
a lo
nger
Dat
a B
ridge
Cab
le,
use
Indo
or D
ata
Cab
le a
nd O
utdo
or R
J45
Hou
sing
.
RJ4
5 M
ale
Con
nect
or H
ousi
ng IP
67D
E.A
C.0
1000
00
Pixe
l Dis
tribu
tor
(Incl
uded
with
Stri
ng R
GB
)
Strin
g R
GB
(DO
.SA
.701
4000
)
512
DM
X C
hann
els
per o
utpu
t
But
ler
1600
01
CO
NTR
OLL
ERPo
wer
ed v
ia T
X C
onne
ct D
ata
Cab
le
62.5
mm
/2.4
6D
ot P
itch:
5 D
ots
1937
.5m
m/7
6.28
32 D
ots
Mes
h/St
ring
Lead
Ex
tens
ion
Cab
le (2
.5m
/8.2
ft)(D
O.A
C.0
0007
00)
(Max
. 2 e
xten
sion
s pe
r lea
d)
A
B
C
D
A to
B: 1
00 m
eter
s
C
ON
TRO
LLER
to F
IXTU
RE.
C to
D: 3
5 m
eter
s
PO
WER
SU
PPLY
to F
IXTU
RE.
CA
BLI
NG
LEN
GTH
S
CA
UTI
ON
: P
LEA
SE
EN
SU
RE
TH
AT
THE
PO
WE
R IS
SW
ITC
HE
D O
FF W
HE
N T
HE
DA
TA C
AB
LES
AR
E B
EIN
G C
ON
NE
CTE
D.
FAIL
UR
E T
O D
O S
O W
ILL
RE
SU
LT IN
DA
MA
GE
TO
TH
E P
RO
DU
CTS
AN
D V
OID
TH
E P
RO
DU
CT
WA
RR
AN
TY.
-
String and Mesh Installation Guide www.traxontechnologies.com 06/12 v0.2 19
FIG 11: Mesh Typical Connection Example Indoors
Part
Num
bers
for I
ND
OO
R M
esh
RG
B S
yste
m
DO
.MA
.701
4000
M
esh
RG
B
PS.IC
.001
0000
LE
D E
ngin
e Sm
art 1
50W
Indo
or
1600
01
But
ler
TI.Z
I.000
0100
TX
Con
nect
Sm
art I
ndoo
r Pow
er/D
ata
Inje
ctor
Box
TE.A
C.0
0001
00
TX C
onne
ct S
mar
t Ind
oor/O
utdo
or B
ridge
Cab
le (5
m/1
6.4f
t)
DO
.AC
.000
0700
M
esh/
Strin
g Le
ad E
xten
sion
Cab
le (2
.5m
/8.2
ft)
DI.I
C.x
xxxx
xx
TX C
onne
ct D
ata
Cab
le
PS.A
C.x
xxxx
xx
AC
Pow
er C
ord
AC
110
V/22
0V 5
0/60
Hz
AC
Pow
er C
ord
(PS.
AC
.xxx
xxxx
)
TX C
onne
ct D
ata
Cab
le(D
I.IC
.xxx
xxxx
)
TX C
onne
ct D
ata
Cab
le(D
I.IC
.xxx
xxxx
)To
add
ition
al u
nit.
TX C
onne
ct S
mar
t Ind
oor
Pow
er/D
ata
Inje
ctor
Box
(TI.Z
I.000
0100
)
TX C
onne
ct S
mar
tIn
terc
onne
ctio
n C
able
(TI.I
C.x
xxxx
xx)
LED
Eng
ine
Smar
t 150
W In
door
(PS.
IC.0
0100
00)
PS.IC
.001
0000
incl
udes
1x
30cm
TX C
onne
ct S
mar
t Int
erco
nnec
tion
Cab
le
TX C
onne
ct S
mar
t Ind
oor/O
utdo
or B
ridge
Cab
le (5
m/1
6.4f
t)(T
E.A
C.0
0001
00)
IND
OO
RO
UTD
OO
R
TX C
onne
ct S
mar
t Ind
oor
Exte
nsio
n C
able
(TI.E
C.x
xxxx
xx)
Ava
ilabl
e in
0.5
m, 1
m, 3
m, 5
m, 1
0m
Exte
nd u
sing
Pixe
l Dis
tribu
tor
(Incl
uded
with
Mes
h R
GB
)
Mes
h R
GB
(DO
.MA
.701
4000
)
62.5
mm
/2.4
6D
ot P
itch:
512
DM
X C
hann
els
per o
utpu
t
But
ler
1600
01
CO
NTR
OLL
ERPo
wer
ed v
ia T
X C
onne
ct D
ata
Cab
le
62.5
mm
/2.4
6D
ot P
itch:
5 D
ots
1937
.5m
m/7
6.28
32 D
ots
Mes
h/St
ring
Lead
Ex
tens
ion
Cab
le (2
.5m
/8.2
ft)(D
O.A
C.0
0007
00)
(Max
. 2 e
xten
sion
s pe
r lea
d)
A
B
C
D
A to
B: 1
00 m
eter
s
C
ON
TRO
LLER
to F
IXTU
RE.
C to
D: 3
5 m
eter
s
PO
WER
SU
PPLY
to F
IXTU
RE.
CA
BLI
NG
LEN
GTH
S
CA
UTI
ON
: P
LEA
SE
EN
SU
RE
TH
AT
THE
PO
WE
R IS
SW
ITC
HE
D O
FF W
HE
N T
HE
DA
TA C
AB
LES
AR
E B
EIN
G C
ON
NE
CTE
D.
FAIL
UR
E T
O D
O S
O W
ILL
RE
SU
LT IN
DA
MA
GE
TO
TH
E P
RO
DU
CTS
AN
D V
OID
TH
E P
RO
DU
CT
WA
RR
AN
TY.
-
String and Mesh Installation Guide www.traxontechnologies.com 06/12 v0.2 20
FIG 12: Optional Mesh Outdoor Connection Example
Part
Num
bers
for O
UTD
OO
R M
esh
RG
B S
yste
m
DO
.MA
.701
4000
M
esh
RG
B
PS.O
A.0
0100
00
LED
Eng
ine
Smar
t 150
W O
utdo
or
1600
01
But
ler
TE.Z
I.000
0100
TX
Con
nect
Sm
art O
utdo
or P
ower
/Dat
a In
ject
or B
ox
TE.IC
.xx0
0000
TX
Con
nect
Sm
art O
utdo
or In
terc
onne
ctio
n C
able
DE.
AC
.000
0100
TX
Con
nect
Dat
a In
door
/Out
door
Brid
ge C
able
(5m
/16.
4ft)
DO
.AC
.000
0700
M
esh/
Strin
g Le
ad E
xten
sion
Cab
le (2
.5m
/8.2
ft)
LED
Eng
ine
Smar
t 150
W O
utdo
or(P
S.O
A.0
0100
00)
AC
110
V/22
0V 5
0/60
Hz
TX C
onne
ct S
mar
t Out
door
Pow
er/D
ata
Inje
ctor
Box
(TE.
ZI.0
0001
00)
IND
OO
RO
UTD
OO
R
TX C
onne
ct D
ata
Indo
or/O
utdo
or B
ridge
Cab
le (5
m/1
6.4f
t)(D
E.A
C.0
0001
00)
TX C
onne
ct D
ata
Indo
or/O
utdo
or B
ridge
Cab
le (5
m/1
6.4f
t)(D
E.A
C.0
0001
00)
TX C
onne
ct S
mar
t Out
door
Inte
rcon
nect
ion
Cab
le(T
E.IC
.050
0000
) 5m
/16.
4ft
(TE.
IC.1
5000
00) 1
5m/4
9.2f
t(T
E.IC
.300
0000
) 30m
/98.
4ft
To a
dditi
onal
uni
t.
To c
onst
ruct
a lo
nger
Dat
a B
ridge
Cab
le,
use
Indo
or D
ata
Cab
le a
nd O
utdo
or R
J45
Hou
sing
.
RJ4
5 M
ale
Con
nect
or H
ousi
ng IP
67D
E.A
C.0
1000
00
Pixe
l Dis
tribu
tor
(Incl
uded
with
Mes
h R
GB
)
Mes
h R
GB
(DO
.MA
.701
4000
)
62.5
mm
/2.4
6D
ot P
itch:
512
DM
X C
hann
els
per o
utpu
t
But
ler
1600
01
CO
NTR
OLL
ERPo
wer
ed v
ia T
X C
onne
ct D
ata
Cab
le
62.5
mm
/2.4
6D
ot P
itch:
5 D
ots
1937
.5m
m/7
6.28
32 D
ots
Mes
h/St
ring
Lead
Ex
tens
ion
Cab
le (2
.5m
/8.2
ft)(D
O.A
C.0
0007
00)
(Max
. 2 e
xten
sion
s pe
r lea
d)
A
B
C
D
A to
B: 1
00 m
eter
s
C
ON
TRO
LLER
to F
IXTU
RE.
C to
D: 3
5 m
eter
s
PO
WER
SU
PPLY
to F
IXTU
RE.
CA
BLI
NG
LEN
GTH
S
CA
UTI
ON
: P
LEA
SE
EN
SU
RE
TH
AT
THE
PO
WE
R IS
SW
ITC
HE
D O
FF W
HE
N T
HE
DA
TA C
AB
LES
AR
E B
EIN
G C
ON
NE
CTE
D.
FAIL
UR
E T
O D
O S
O W
ILL
RE
SU
LT IN
DA
MA
GE
TO
TH
E P
RO
DU
CTS
AN
D V
OID
TH
E P
RO
DU
CT
WA
RR
AN
TY.
-
String and Mesh Installation Guide www.traxontechnologies.com 06/12 v0.2 21
5. CARE AND MAINTENANCE
TRAXON PRODUCTS ARE OF SUPERIOR DESIGN AND qUALITY AND SHOULD BE
TREATED WITH CARE. THE RECOMMENDATIONS BELOW WILL HELP FULFILL ANY
WARRANTY OBLIGATIONS AND GAIN GOOD USE AND LONGEVITY FROM THE PRODUCTS.
Do not attempt or use the product(s) until you read and understand the installation instructions. Failure to adhere to these instructions could result in serious injury or property damage.
Do not use product(s) if cables are damaged.
Do not connect cables and connectors when wet or in wet area. Moisture on bare connectors can cause electric shock and damage to product(s).
Do not use product(s) in extreme heat environment. Ensure there is sufficient airflow and use cool air circulation if required.
Do not drop, knock, or shake product(s). Rough handling can damage the electronics and void the warranty.
Do not use harsh chemicals, cleaning solvents, or strong detergents to clean products. Wipe with a damp cloth on housings and a dry cloth on electronics to remove dirt or dust.
Do not attempt to service or repair the product(s) unless done by an authorized service personnel. Contact your local Traxon office or distributor for details.
6. TROUBLESHOOTING
CAUTION: ENSURE POWER SUPPLY IS OFF WHEN DISCONNECTING/CONNECTING CABLES
Problem Cause Possible Solutions
Product does NOT light up after installation
Incorrect power connection Check Mains Power
Check power supply leads and wire connections
Check status lights on Pixel Distributor
Ensure output wires are connected with proper polarity
Shadowing Light source covered Check for cables, wires or unwanted debris covering LED light source
Modules are dim Excess products connected Ensure the power supplies are not overloaded due to an excess of products connected
Flickering Incorrect power input/Excess products connected
Ensure the input voltage is correct
Ensure the power supplies are not overloaded due to an excess of products connected
If problems persist or the product is not working as specified, please contact your nearest authorized service center or Traxon Technologies office for assistance.
-
String and Mesh Installation Guide www.traxontechnologies.com 06/12 v0.2 22
7. TECHNICAL SPECIFICATION
Light Source: 32 High intensity Nichia SMD LEDs on each string. Total 160 LEDs on 5 strings
Beam Angle: 120
Power Input*: 24V DC
Power Consumption: 88W max. (Pixel Distributor and 5 Strings/Mesh unit)
Weight: 300g (0.66lbs) per string, 4.2kg (9.2lbs) Mesh unit0.9kg (2lbs) Pixel Distributor, 0.3kg (0.66lbs) Mounting wires
Operating Temperature: 20C to 50C (4F to 122F)
Storage Temperature: 40C to 70C (40F to 158F)*For use with TRAXON LED Engine Smart 150W Indoor (PS.IC.0010000), LED Engine Smart 150W Outdoor (PS.OA.0010000) power units.
As with all electronic devices, LED output degrades over time - a term called lumen depreciation. This also explains why it is nearly impossible to expect photometric performances of two LED products with different service life spans to be the same. The rate of LED degradation is a complex function of many factors such as operating efficiency, duration of continuous operation, and operating conditions (e.g. ambient temperature).Because LEDs are semiconductor devices, their performances are subject to inherent variability commonly found in semiconductor industry. To improve consistency in performance across the same product. LED manufacturers sort LEDs into bins according to different preset parameters, such as forward driving voltage, illumination, etc. Whereas binning is a sorting function, it is not a correction process. Inherent variability in the manufacturing process always results in different binning distributions according to different production lots. Traxon uses automatically binned LEDs on its products, thereby minimizing output variations within the model range.
8. WARRANTY STATEMENTTraxon warrants its Products against material or workmanship defects for a period of three (3) years from date of purchase, provided that the purchased items are used under the conditions stated in this user manual.
Please refer www.traxontechnologies.com for all warranty terms and conditions.
-
Please check for the latest updates and changes on the Traxon website. 2012 TRAXON TECHNOLOGIES ALL RIGHTS RESERVED. Information is subject to change without prior notice.WWW.TRAXONTECHNOLOGIES.COM