Enhancements in Pulsed Eddy Current Examination

of Insulated Component

Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE, Marc GRENIER,

Charles TREMBLAY, Dr. Marco Michele SISTO, Martin TURGEON

Presented by: Michel BEZEMER

Page 2: Enhancements in Pulsed Eddy Current ... - NDT Sweden · Enhancements in Pulsed Eddy Current Examination of Insulated Component Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE,

PEC Working Principle (1/3)

• PEC consists in the analysis of the transient eddy current inside a conductive

component following a sharp electromagnetic transition. There are 3 phases:

1. The emission phase (the pulse) during which the probe injects magnetic fields that penetrate and stabilize in

the component thickness

2 © Eddyfi NDT Inc. 2009–2016

Excitation pulse

Magnetic response

Time

Time

1

1

Page 3: Enhancements in Pulsed Eddy Current ... - NDT Sweden · Enhancements in Pulsed Eddy Current Examination of Insulated Component Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE,

PEC Working Principle (2/3)

• PEC consists in the analysis of the transient eddy current inside a conductive

component following a sharp electromagnetic transition. There are 3 phases:

2. The cut-off phase which induces strong eddy currents into the component when the magnetic field emission is

stopped abruptly

3 © Eddyfi NDT Inc. 2009–2016

Excitation pulse

Magnetic response

Time

Time

2

2

Page 4: Enhancements in Pulsed Eddy Current ... - NDT Sweden · Enhancements in Pulsed Eddy Current Examination of Insulated Component Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE,

PEC Working Principle (3/3)

• PEC consists in the analysis of the transient eddy current inside a conductive

component following a sharp electromagnetic transition. There are 3 phases:

3. The reception phase during which magnetic sensors measure the decay of the eddy currents as they diffuse

into the material thickness

4 © Eddyfi NDT Inc. 2009–2016

Excitation pulse

Magnetic response

Time

Time

3

3

Page 5: Enhancements in Pulsed Eddy Current ... - NDT Sweden · Enhancements in Pulsed Eddy Current Examination of Insulated Component Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE,

A-Scan in Reception Phase

Early in the A-scan:

• Eddy currents diffuse in the WT as if they are in an infinite wall

• The decay rate follows a “power law” relation that:

• Produces a straight line in a Log-Log scale

• Produces a rapid drop in a Log-Lin scale

5 © Eddyfi NDT Inc. 2009–2016

1 10 100

Vo

ltag

e -

Log

scal

e (v

)

Time - Log scale (ms)

Log-Log Scale

0 50 100 150

Vo

ltag

e -

Log

scal

e (v

)

Time - Linear scale (ms)

Log-Lin Scale

𝑉 ∝ 𝑡−𝑎 𝑉 ∝ 𝑡−𝑎

Page 6: Enhancements in Pulsed Eddy Current ... - NDT Sweden · Enhancements in Pulsed Eddy Current Examination of Insulated Component Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE,

0 50 100 150

Vo

ltag

e -

Log

scal

e (v

)

Time - Linear scale (ms)

Log-Lin Scale

A-Scan in Reception Phase

Later in the A-scan

• Eddy currents reach the far side of the WT

• The decay rate follows an “exponential” relation that:

• Produces a rapid drop in a Log-Log scale

• Produces a straight line in a Log-Lin scale

6 © Eddyfi NDT Inc. 2009–2016

1 10 100

Vo

ltag

e -

Log

scal

e (v

)

Time - Log scale (ms)

Log-Log Scale

𝑉 ∝ 𝑒−𝑡

𝜏 𝑉 ∝ 𝑒−𝑡

𝜏

Page 7: Enhancements in Pulsed Eddy Current ... - NDT Sweden · Enhancements in Pulsed Eddy Current Examination of Insulated Component Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE,

0 50 100 150

Vo

ltag

e -

Log

scal

e (v

)

Time - Linear scale (ms)

Log-Lin Scale

A-Scan in Reception Phase

Thinner wall thicknesses change the shape of the A-scan

• Shorter eddy current diffusion time

• Quicker signal drop in a Log-Log scale

• Different slope in a Log-Lin scale

7 © Eddyfi NDT Inc. 2009–2016

1 10 100

Vo

ltag

e -

Log

scal

e (v

)

Time - Log scale (ms)

Log-Log Scale

0 50 100 150

Vo

ltag

e -

Log

scal

e (v

)

Time - Linear scale (ms)

Log-Lin Scale

1 2

3 4

Region of interest

with Lyft™

Page 8: Enhancements in Pulsed Eddy Current ... - NDT Sweden · Enhancements in Pulsed Eddy Current Examination of Insulated Component Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE,

PEC Reinvented

8 © Eddyfi NDT Inc. 2009–2016

15 25 35 45 55 65 75 85

Vo

ltag

e -

Log

scal

e (v

)

Time - Linear scale (ms)

Log-Lin Scale

1 2

3 4

Two major advantages:

• Shorter acquisition time

• Mostly immune to signal amplitude variations

Page 9: Enhancements in Pulsed Eddy Current ... - NDT Sweden · Enhancements in Pulsed Eddy Current Examination of Insulated Component Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE,

What is Pulsed Eddy Current?

9 © Eddyfi NDT Inc. 2009–2016

Pulse Stop Listen

Excitation pulse

Magnetic response

Time

Time

1

1

Excitation pulse

Magnetic response

Time

Time

2

2

Excitation pulse

Magnetic response

Time

Time

3

3

Allows the measurement of wall thickness at high lift off

Page 10: Enhancements in Pulsed Eddy Current ... - NDT Sweden · Enhancements in Pulsed Eddy Current Examination of Insulated Component Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE,

A World of Applications

10 © Eddyfi NDT Inc. 2009–2016

Corrosion under Insulation

(CUI) Flow Accelerated Corrosion

(FAC)

Scab Corrosion

Page 11: Enhancements in Pulsed Eddy Current ... - NDT Sweden · Enhancements in Pulsed Eddy Current Examination of Insulated Component Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE,

A World of Applications

11 © Eddyfi NDT Inc. 2009–2016

Corrosion under Insulation

(CUI)

Potential applications include:

• Insulated pipes

• Tanks

• Vessels

• Sphere legs

• Any carbon steel with

insulation or cladding

Page 12: Enhancements in Pulsed Eddy Current ... - NDT Sweden · Enhancements in Pulsed Eddy Current Examination of Insulated Component Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE,

Introducing Lyft™ - PEC Reinvented

FAST

• Dynamic mode (unique to Lyft):

• Probe moving speed up to 100mm/s (4in/s)

• No need for grid marking the sample, just straight lines

RELIABLE

• Less operator-dependent

• Less affected by lift-off variations and weather jacket overlaps

• Not sensitive to probe motion

VERSATILE

• Galvanized steel weather jacket, and scab/blistering-capable

• Works at lift offs up to 12’’ (300 mm)

• Wall thickness up to 4” (100 mm)

• Through concrete, polymer coating and chicken wire

• Near metallic structures such as nozzles, flanges, pipe supports

12 © Eddyfi NDT Inc. 2009–2016

Lyft™ system

Page 13: Enhancements in Pulsed Eddy Current ... - NDT Sweden · Enhancements in Pulsed Eddy Current Examination of Insulated Component Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE,

What Pulsed Eddy Currents doesn’t do

Pulsed Eddy Current work best on large corrosion patches, especially at high lift off.

Pulsed Eddy Current does not detect:

• Cracks

• Small pitting

13 © Eddyfi NDT Inc. 2009–2016

Page 14: Enhancements in Pulsed Eddy Current ... - NDT Sweden · Enhancements in Pulsed Eddy Current Examination of Insulated Component Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE,

Where does Lyft ™ fit in the NDE Tool Belt?

• Permits expansion of inspection scope and frequency without

increasing schedule

• Can inspect in-service components

• Monitoring without shut down (high or low temperature components)

• Does not require removal insulation or cladding

• Broader screening permits more focused application of RT

and UT

14 © Eddyfi NDT Inc. 2009–2016

Page 15: Enhancements in Pulsed Eddy Current ... - NDT Sweden · Enhancements in Pulsed Eddy Current Examination of Insulated Component Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE,

Measuring Defects Through Insulation

15 © Eddyfi NDT Inc. 2009–2016

What happens when the probe scans

over a defect?

Wall Thickness 2’’ 1.5’’ 1’’ 0.75’’ 0.5’’ 0.25’’

Wall Relative Thickness 100% 75% 50% 37.5% 25% 12.5%

Measured Thickness 100% 77.2% 49.8% 36.0% 24.9% 13.1%

Page 16: Enhancements in Pulsed Eddy Current ... - NDT Sweden · Enhancements in Pulsed Eddy Current Examination of Insulated Component Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE,

Measuring Defects Through Insulation

16 © Eddyfi NDT Inc. 2009–2016

What happens when the probe scans

over a defect?

Scanning a defect smaller than the footprint

leads to undersizing

Page 17: Enhancements in Pulsed Eddy Current ... - NDT Sweden · Enhancements in Pulsed Eddy Current Examination of Insulated Component Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE,

Lab mockup sample – Flat bottom holes

Plate WT 0.5’’ (12.7 mm)

Insulation height 2’’ (50.8 mm)

Sample

What is Undersizing?

17 © Eddyfi NDT Inc. 2009–2016

Page 18: Enhancements in Pulsed Eddy Current ... - NDT Sweden · Enhancements in Pulsed Eddy Current Examination of Insulated Component Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE,

Lab mockup sample – Flat bottom holes

Plate WT 0.5’’ (12.7 mm)

Insulation height 2’’ (50.8 mm)

What is Undersizing?

18 © Eddyfi NDT Inc. 2009–2016

Defect Diameter Real WT Measured

WT

A 3’’ 66% 89.5%

B 6’’ 33% 66.8%

C 3’’ 33% 85.7%

A B

C

Page 19: Enhancements in Pulsed Eddy Current ... - NDT Sweden · Enhancements in Pulsed Eddy Current Examination of Insulated Component Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE,

What is the signal like when we undersize?

19 © Eddyfi NDT Inc. 2009–2016

Nominal + Defect = Actual Signal

2 20

Sign

al -

Lo

g Sc

ale

(V)

Time - Log Scale (ms)

Log - Log Scale

2 22 42

Sign

al -

Lo

g Sc

ale

(V)

Time - Lin Scale (ms)

Log - Lin Scale

Page 20: Enhancements in Pulsed Eddy Current ... - NDT Sweden · Enhancements in Pulsed Eddy Current Examination of Insulated Component Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE,

Compensated Wall Thickness

Isolate the defect contribution from the signal

We use an analytical equation for each component of the signal

Analyze a defective region rather than a single data point

20 © Eddyfi NDT Inc. 2009–2016

2 22 42

Sign

al -

Lo

g Sc

ale

(V)

Time - Log Scale (ms)

Log - Lin Scale

Page 21: Enhancements in Pulsed Eddy Current ... - NDT Sweden · Enhancements in Pulsed Eddy Current Examination of Insulated Component Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE,

Lab mockup sample – Flat bottom holes

Plate WT 0.5’’ (12.7 mm)

Insulation height 2’’ (50.8 mm)

Compensating for the Undersizing Phenomenon

21 © Eddyfi NDT Inc. 2009–2016

Defect Diameter Real WT Measured

WT

Compensated

WT

A 3’’ 66% 89.5% 67.1%

B 6’’ 33% 66.8% 36.7%

C 3’’ 33% 85.7% 39.8%

Page 22: Enhancements in Pulsed Eddy Current ... - NDT Sweden · Enhancements in Pulsed Eddy Current Examination of Insulated Component Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE,

Compensated Wall Thickness on Real Corrosion

22 © Eddyfi NDT Inc. 2009–2016

Scab corrosion

Plate WT 0.35’’ (8.9 mm)

Insulation None

Sample

Page 23: Enhancements in Pulsed Eddy Current ... - NDT Sweden · Enhancements in Pulsed Eddy Current Examination of Insulated Component Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE,

Compensated Wall Thickness on Real Corrosion

23 © Eddyfi NDT Inc. 2009–2016

Scab corrosion

Plate WT 0.35’’ (8.9 mm)

Insulation None

Sample

29%

32%

52%

57%

Page 24: Enhancements in Pulsed Eddy Current ... - NDT Sweden · Enhancements in Pulsed Eddy Current Examination of Insulated Component Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE,

Compensated Wall Thickness on Real Corrosion

24 © Eddyfi NDT Inc. 2009–2016

Scab corrosion

Plate WT 0.35’’ (8.9 mm)

Insulation None

Sample

29%

32%

30% 31%

Page 25: Enhancements in Pulsed Eddy Current ... - NDT Sweden · Enhancements in Pulsed Eddy Current Examination of Insulated Component Dr. Vincent DEMERS-CARPENTIER, Dr. Maxime ROCHETTE,

Conclusions

• Lyft™ is a fast, flexible and reliable screening

tool which measures wall thickness through

insulation and cladding

• Compensated Wall Thickness tool addresses

the main weakness of PEC: undersizing

• Compensated Wall Thickness gives optimal

results when applied to high resolution, low

noise data sets

25 © Eddyfi NDT Inc. 2009–2016