1 AXIS SOLAR TRACKER TECHNICAL DATASHEET
Tracker axis Principal rotation axis G1 North - South Horizontal axis
Control System Master PLC which communicates with a series of slaves PLC´s using a protocol designed by ERCAM. System free of shadows using a tracking algorithm
Rotation Capacity
G1 = + / - 55 º
Tracking System
PLC astronomic programming
Solar modules per beam
Total length of Panel Frames
Maximum number of consecutive beams
18, 24 solar modules ( depending on external dimensions) up to 5 meters ( 196.85 in)
up to 10 beams ( depending on field slope)
Internal Communication External Communication
Standard electrical wiring between PLC master and slaves using ERCAM_ BU S protocol
The master PLC has Ethernet interface making easy to monitoring and actuating on the trackers
Beam weight
Aprox. 353 Kg (778 lb) full equipped without panels
Solar Tracker max. height 5701 mm ( 224.45 in) for maximum inclination angle
( G1 = 55 º )
Monitoring - Tracker Control ( real & theoretical position ).Standard - Inverter Production .ERCAM development under demand - Speed wind monitoring. Software under demand
Principal axis drive
Hydraulic lineal actuator
Protections
- Electrical over current protection for control system - High wind speed protection system ( Programmable)
Hydraulic Pump (1 per tracker)
Power 0.375 Kw , monofasic 220/ 110 Volts AC
Master control box Slave control box
Fully wired IP 65 .Capable to control up 25 trackers Fully wired IP 65
Principal Structure Hot dip galvanized steel according to ISO 1461
Solar modules structure Aluminium 6061 T6
Defense position Horizontal positioning at speed upper 60 Kmh ( 37.28 mph)
Screws Hot dip galvanized steel and/ or steel with anti corrosion
high resistance surface treatment .
CE marking
Complies with the principal design, calculus and safety European standards
Foundation
Footings, typically 0.5 x 1 meters ( 19.69 x 39.37 in ) and 2 m (78.74 in) deep
Guarantee
Up to 3 years on parts, extendable under contract
ERCAM USA ErcamSo lar Tracking System, Inc. 230 California St, 5 th floor. San Francisco-California, USA Contact name : Adrian Inchaurza +1 415 640 1058 [email protected]
P. I. Cabanilla s Nº 1 Parcela 1, nave nº 66 C/ Frco. de Medina y Mendoza 19171 Guadalajara - Spain Tfn: + 34 949 20 17 26 Fax: + 34 949 20 06 99 www.ercam.es