Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ......
Transcript of Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ......
![Page 1: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/1.jpg)
Energy Efficiency Masterclass
for Industry
![Page 2: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/2.jpg)
2Government of South Australia
ICN Gateway
• Pivotal link between major project
requirements and suppliers
• ~70,000 company listings
• ~$400 billion in projects
![Page 3: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/3.jpg)
Setting the Scene
Industry and Energy Efficiency
• Competitive Business Environment
• Industry Productivity
• Energy Prices
• Industry Response
![Page 4: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/4.jpg)
Industry Response
• Focused Assessments (AS/NZS 3598.2)
• Type 1 Audit - to identify key opportunities
• Type 3 Audit – focusing on key areas only
• Business Case for Investment
• Competes with other industry investments
• Finance for implementation
![Page 5: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/5.jpg)
Aim
Participants will leave this session with a clear
understanding of key energy efficiency
improvements that can be implemented within their
organisations.
![Page 6: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/6.jpg)
Objectives
Masterclass Objectives address three themes:
• Financial
• Practical
• Technical
![Page 7: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/7.jpg)
Kevin JonesBranch Manager, CAPS
![Page 8: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/8.jpg)
SUBHEADING
ENERGY EFFICIENT COMPRESSED AIR SYSTEMSPresented by Kevin Jones, CAPS Australia
![Page 9: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/9.jpg)
1. Why Compressed Air?
2. 5 x Facts About Compressed Air
3. Review Maintenance & Managing Leaks
4. Compressed Air Energy Auditing
5. Case Studies & Upgrading Equipment
AGENDA
![Page 10: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/10.jpg)
MOST INDUSTRIES DEPENDHEAVILY ON COMPRESSED AIR.
![Page 11: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/11.jpg)
COMPRESSEDAIR.
Flexible Convenient
Clean Safe
Highly Energy Intensive!
![Page 12: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/12.jpg)
5 FACTS ABOUTCOMPRESSED AIR.
![Page 13: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/13.jpg)
FACT#1
Compressed air is used
extensively by industry.
10-15% of all industrial electricity is used to generate compressed air.
ALL OTHER ELECTRICITY DEMANDS.
COMPRESSED AIR
![Page 14: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/14.jpg)
FACT#2
Compressed air is an inefficient form of energy.
90% of input electrical energy is discharged as waste heat. 10% Compressed Air
90% Waste HeatAir Compressor
![Page 15: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/15.jpg)
FACT#3
Compressors can be inefficient at part load.
At 50% load, typical controls consume 85% power.
WA
STE
![Page 16: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/16.jpg)
FACT#4
Compressed air is wasted profusely.
Typically, only 50% of compressed air is used for productive demands.
Productive Demands
LeaksInnappropriate
Uses
System Losses
Artificial Demands
![Page 17: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/17.jpg)
FACT#5
Electricity is by far the greatest cost of compressed air.
Over 10 years, the energy cost will be 10 to 30 times the initial capital cost.
Capital
InstallationMaintenance
Energy
![Page 18: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/18.jpg)
REVIEW &MAINTENANCE.
Why servicing pays.
• Less prone to breakdown
• Efficiency drops
![Page 19: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/19.jpg)
REVIEW &MAINTENANCE.Leak Detection – Leak Management
![Page 20: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/20.jpg)
WHY ARE AIR SYSTEMSINEFFICIENT?
Old and inefficient equipmen
t
![Page 21: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/21.jpg)
HOW CAN THEYBE IMPROVED?
![Page 22: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/22.jpg)
8kW LossesH
igh
Eff
icie
ncy
Var
iab
le S
pee
d
Air
Co
mp
ress
or
Op
erat
ing
at 5
0%
Lo
ad
70
kW
Inp
ut
Elec
tric
ity
60
kW
Load
ed P
ow
er
Typ
ical
Air
Co
mp
ress
or
Op
erat
ing
at 5
0%
Lo
ad
Systems Approach
24
46kW
Heat Recovery System
Transmission
System
1kW Non-Productive Waste
5kW Productive
Demands
10
0kW
Load
ed P
ow
er
6kW
Compressed Air Generated
Transmission
System
5kW Non-Productive
Waste
5kW Productive Demands
18
0kW
Inp
ut
Elec
tric
ity
10kWCompressed Air Generated
90kWWasted Heat
60% Reduction in Energy
Consumption!6
0kW
Un
load
ed
Po
wer
60kWLosses &
Unusable
Waste Heat
![Page 23: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/23.jpg)
AIR ENERGYAUDITING.
FLOW POWER PRESSURE
What you don’t measure, you can’t improve!
What are the
savings with an
upgrade in
technology?
How much does it cost
to operate your system
annually?
How does your system vary?
Daily, weekly, monthly, quarterly,
annually?
Develop an
understanding of
the system
How do we
compare with
best practice?
![Page 24: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/24.jpg)
AIR ENERGYAUDITING.
• Relatively simple and low costs
• Collect system data during typical operational week
• Determine equipment and capabilities
• Develop a baseline of demand and performance
• Review and confirm appropriate service regime
• Uncover compressed air issues (i.e. pressure or quality)
![Page 25: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/25.jpg)
WHAT ARE THEOPPORTUNITIES?
SUPPLY SIDE• Efficient part-load
compressors• Multi-stage compression• Storage and controls• Pressure set points• Maintenance• Heat recovery
DEMAND SIDE• Detect and fix leaks• Inappropriate demands• Central sequence control• Pressure drop issues• Pressure regulation• Demand anomalies
![Page 26: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/26.jpg)
CASE STUDY #1SIMPLE MANUFACTURING APPLICATION.
• Manufacturing facility seeking energy savings opportunities
• Only one compressor in operation
• Data logging and analysis undertaken
• Along with a demand-side review
![Page 27: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/27.jpg)
Freq
uen
cy (
%)
Demand Profile
Po
we
r (k
W)
Efficiency Profile
Actual Demand
Equipment Capacity
![Page 28: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/28.jpg)
HOLISTICSOLUTION.
SUPPLY SIDE• Smaller Compressor
with Variable Speed installed
• Reduced pressure set point
DEMAND SIDESmall reduction in demand via identification and repair of a few leaks, plus change in usage practises
![Page 29: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/29.jpg)
OUTCOMES.
• Implemented solution saves $45k/annum in electricity.
• Additional savings in maintenance.
• Payback on total project cost within 1.7years.
• More reliable equipment.
• Delivers more stable pressure and less wear and tear on downstream equipment.
![Page 30: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/30.jpg)
CASE STUDY #2KILCOY PASTORAL.
• Abattoir seeking compressor upgrade with energy savings
• Three compressors in operation (3 constant speed unloading)
• Data logging and analysis undertaken
• Project recommendations undertaken by client
• One new large VSD compressor with two existing compressors
• Data logging for verification purposes confirmed savings
![Page 31: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/31.jpg)
PLANT ROOMBEFORE.
![Page 32: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/32.jpg)
STACKED AVERAGE POWER CHART.
PRESSURE RANGE CHART.
![Page 33: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/33.jpg)
PLANT ROOMAFTER.
![Page 34: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/34.jpg)
AVG. POWER BEFORE VS AFTER
PRESSURE BEFORE VS AFTER
![Page 35: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/35.jpg)
SYSTEM EFFICIENCYIMPROVEMENT.
Theoretical Ideal
System before upgrade
System after upgrade
Demand profile
![Page 36: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/36.jpg)
BEFORE & AFTERSTATISTICS.
July 2012
3 x 75kWFixed Speed units
February 2013
1 x 160kW VSD +2 x 75 kW fixed speed
Change
Average Flow (m3/min) 23.8 26.2 +10 %
Average Power (kW) 201.1 159.6 - 20.6 %
Average Pressure (kPa) 744.8 735.7 - 1.2 %
Air Production Efficiency (kW/m3/min) 8.4 6.1 - 27.4 %
Overall System Efficiency (kW/m3/min) 10.1 6.8 - 32.7 %
▪ Slight increase in average flow
▪ Vast improvement on overall system efficiency
▪ Savings in the region of $15,000 per month
![Page 37: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/37.jpg)
OUTCOMES.
• Implemented solution saves $15k/month in electricity
• Additional savings in maintenance
• Payback on capital cost within 2 years
• More reliable equipment
• Delivering more stable pressure and less wear and tear on downstream equipment
![Page 38: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/38.jpg)
IN CLOSING.
• Compressed air a very costly ‘invisible’ energy.
• Significant opportunities exist for substantial cost savings with fast payback on solutions.
• Seek assistance from specialised professional services providers
![Page 39: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/39.jpg)
THANK YOU
![Page 40: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/40.jpg)
Craig DurrheimBusiness Development Manager, Danfoss Drives
![Page 41: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/41.jpg)
43 | Danfoss Drives
Electrical Motor ControlsEnergy Efficiency Expo22nd August 2018
Craig Durrheim
BDM SA / NT
![Page 42: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/42.jpg)
Overview1) Developments in motor technology2) Considerations when using VSDs3) Enhancements in VSD technology
![Page 43: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/43.jpg)
45 | Danfoss Drives
![Page 44: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/44.jpg)
46 | Danfoss Drives
BasicSystem
AlternativeSystem
AdvancedSystem
VLT®
FlexConceptTM
Mechanicalefficiency
Worm gear 70% Helical gear 89% Bevel gear 95%Optimized bevel gear
96%
Electrical Efficiency
AC MotorIE1 1.5 kW
77,2%AC Motor
IE1 1.5 kW77,2%
AC MotorIE2 1.5 kW
82,8% PM motor 96%
Inverterefficiency
StandardInverter
95% FC(D)302 97% FC(D)302 97% FC(D)302 97%
Chain efficiency
88%
TOTALefficiency
51,3% 62,6% 71,5% 89,4%
ENERGY SAVING
Efficiency comparison:
IE classes Gears
![Page 45: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/45.jpg)
47 | Danfoss Drives
Energy Savings:
63%!
from 4 kW
to 1.48kW
Assuming 3000 Hrs/year and 15c/kWh savings approx. = $1,134 / year
A Coca Cola Plant
![Page 46: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/46.jpg)
48 | Danfoss Drives
![Page 47: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/47.jpg)
Considerations when utilising Variable Speed Drives
![Page 48: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/48.jpg)
50 | Danfoss Drives
Relationship Flow, Pressure & Power for Centrifugal Motors
100kW load at 90% speed, running 10% longer, savings approx. = $9,000 / year.
Cost of 110kW VSD approx. = $10k
![Page 49: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/49.jpg)
51 | Danfoss Drives
LCC =Cic+Cin+Ce+Co+Cn+Cs+Cenv+Cd Cic = initial capital cost
Cin = installation & commissioning costs
Ce = energy costs Co = operating costs
Cm = maintenance costs Cs = downtime & lost production costs
Cenv = environmental costs
Cd = de-commissioning & disposal costs
Two most significant factors: Energy costs Maintenance costs
Variable Speed Drive (VSD) / Power
Drive System (PDS) design can
significantly impact on Life-Cycle Costs
Typical VSD Life-Cycle Costs
![Page 50: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/50.jpg)
52 | Danfoss Drives
Radiated noise
Motor cable
VFD Motor
Motor cable type & length impact RFI conducted emissions on mains supply
Harmonics: 50-2500Hz, Conducted:
9kHz-50MHz, Radiated: 50MHz-2GHz …..
The length & type of motor cable effect the level of conducted RFI emissions on the mains supply
![Page 51: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/51.jpg)
53 | Danfoss Drives
RFI Environment & Product Standards (Note *)
(Note *: Or equivalent local standard)
Generic Environment standard* VSD Product standard
- Facility operators must comply with EN 55011*
- VSD manufacturers must conform with EN 61800-3
1st Environment / Class B Residential Environment: All sites directly connected to the public low voltage power grid, including light industrial areas, are classified as residential or business & commercial environments. (I.E.: do NOT have their own HV/MV distribution transformer)
2nd Environment / Class A Industrial Environment: Operating sites NOT directly connected to the public low voltage power grid, which do have their own HV/MV distribution transformer
![Page 52: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/52.jpg)
54 | Danfoss Drives
Harmonics: causes Harmonics are primarily caused
by loads that draw current in a non-sinusoidal manner. I.E: Non-linear loads, E.G.: UPS, Computer power supplies, VFD, Etc.
Variable Speed Drives (VSD)
Most common design uses 6 pulse rectifier (6 diodes)
5th & 7th harmonic currents
The level of harmonic current depends on:
DC bus capacitor size
Load
Dc / AC chokes, or other filters used??
![Page 53: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/53.jpg)
55 | Danfoss Drives
EMC: Harmonics EffectsCurrent Distortion
Adds to system losses, E.G.:
Overloading / premature aging of transformers, cables & switchgear
Stressing of PF correction caps.
Nuisance tripping of protection relays & circuit breakers, etc
Voltage distortion
Can disturb other equipment:
Malfunction, erratic operation & breakdown of electronic equipment
Increased eddy current losses & torque ripple in DOL connected motors connected to same grid
![Page 54: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/54.jpg)
56 | Danfoss Drives
Output Waveforms (dV/dt vs Sinewave filters)
![Page 55: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/55.jpg)
57 | Danfoss Drives
Our standard Product
Danfoss VLT® Drives have peak voltage and rise
time values compliant with IEC60034-25.
Depending on motor cable type and length on
400V systems, Danfoss VLT® Drives have typical
peak voltage and rise time values compliant with
IEC60034- 17 (curve C in figure 17) Rotating
electrical machines – General Requirements –
Rating and Performance.
Simulation Tools
Danfoss with assistance of SABER software
estimates the dv/dt and Vpeak at the motor
terminals.
Sine Wave Output Filters
Complies with IEC 60034-17
requirements for general purpose
motors with cables up to 500M
<90Kw (1kM for >110kw)
Guaranteed EMC performance
up to 300 M of unshielded cable
Dv/dt Filters
dv/dt<500V/microsec
Upeak <900V
max cable 150m
HF-CM Core
The filter reduces the high-
frequency noise radiated by
motor cables shielded/unshielded
Output Filter Types
![Page 56: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/56.jpg)
58 | Danfoss Drives
Ingress Protection Standards
• IP rating according to IEC 60529
IP54 typically suitable for switch
room. IP55 / 66 may be possible in plant
area <90kW – check conditions
![Page 57: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/57.jpg)
59 | Danfoss Drives
Corrosion Protection
• Levels of contaminants according to IEC 60721-3-3
Note: Class 3C3 protection offers the
high level of protection &
potentially lower maintenance cost
![Page 58: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/58.jpg)
Enhancements in VSD technology
![Page 59: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/59.jpg)
61 | Danfoss Drives
Maintenance functionality
Inverter protection
Motor Side monitoring:
• Earth Fault• Short Circuit• Missing Motor Phase• Motor thermal • Over Current• Electronic Shear pin
Line Side:• Missing supply phase
protection • Transient Protection
Inverter protection
Motor Side monitoring:
• Field Isolator • Short circuit• Earth fault
Line Side:• Missing supply • Transient Protection
Load torque monitoring
(profile data external)
Functions at Run Predictive actionsFunctions at Stop
Helps warn of issues before productions starts reducing
start-up delays.
Minimises damage to plant and equipment during
production
Allows external application profiling to predict application
performance
![Page 60: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/60.jpg)
62 | Danfoss Drives
Application - Filter monitoring & Airflow control (Volume[m3/h] or Pressure[Pa])
1) Filter clog monitoring:• Reduce energy
comsumption• Clean air & indoor
climate
PID Pressure regulation:2. Volume flow3. Pressure level
(air channel)1 2
3
2
31
AHU/RTU
![Page 61: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/61.jpg)
63 | Danfoss Drives
VLT® drive with enclosure size EExtremely compact and powerful
Back-channel cooling with heat pipe technology
• Unique ducted back-channel passes cooling air over heat sinks
• 90% of heat losses are exhausted directly outside of the enclosure
• Dramatically reduces temperature rise
• Reduces contamination of the electroniccomponents.
Built-in options• Fuses
• Disconnect and fuses
• Mains shield
• Brake chopper
• Regen terminals
• Load share terminals
• RFI filter
• Space heater
• USB through door
• Heat sink access panel
• Corrosion-resistant back-
New E Frame Drives:355 to 450kW: 600 W x 2043H500 & 560kW: 700 W x 2043H
![Page 62: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/62.jpg)
64 | Danfoss Drives
Average 85% heat dissipated via segregated back channel using outside cooling air (>/= 110kW)
D–Frame (110-315kW) = 90%E-Frame (355-450kW) = 85%F-Frame (>/500kW) = 80%(400V, 6P drives)
Average 15% heat dissipated into switch room = average 85% reduction in switch room A/C heat load. (>/= 110kW)
85% average lower switch room A/C heat load using thru wall Back Channel Cooling (BCC)
![Page 63: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/63.jpg)
65 | Danfoss Drives
The size of and heat load from AC drives often impacts the cost of switchrooms
4m Shorter
![Page 64: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/64.jpg)
66 | Danfoss Drives
Hypothetical ROI ExampleConsidering BCC (Back Channel Cooling) & Physical size reduction.
• 6 x 450kW, 6 x 110kW, 4 x 55kW VSDs.
•Total VSD Power = 3580kW
•Total Watt loss approx. = 90kW
•No BCC AC Power required approx. = 30kW
•With BCC AC Power required approx. = 6kW
•No BCC: AC Power = $13.5k/annum (+6x5kW AC units)
•With BCC: AC Power = $2.5k/annum (+2x5kW AC units)
•Space saving = 4 linear m @ $12k / m = $48k
![Page 65: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/65.jpg)
67 | Danfoss Drives
Solar Pump Drive
AC 3P TERMINATION
Change over switchAC – 0 – DC
M3
˜
400V, 50Hz 3 PHASEAC SUPPLY
˜
˜
=
DC SUPPLY FROM SOLAR PV CELLS
DC 2P TERMINATION
SPD
DI
20X-100X
Switch enclosur
e
![Page 66: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/66.jpg)
Driven by Drives
![Page 67: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/67.jpg)
Vikram KenjleEnergy Manager, University of Adelaide
![Page 68: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/68.jpg)
Vikram Kenjle – Energy ManagerThe University of Adelaide
2018 Energy Efficiency Expo and Seminar
![Page 69: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/69.jpg)
Cogeneration & Heat Recovery
Topic -
![Page 70: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/70.jpg)
Agenda
• Overview
• Value of Cogeneration & Heat Recovery
• Key Benefits & Pitfalls
• Improving Existing Systems
University of Adelaide 72
![Page 71: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/71.jpg)
What is Cogeneration / CHP?
University of Adelaide 73
Source: Carbon Trust UK, 2012
(80%) ....OVERALL EFFICIENCY…. (55%)
Cogeneration or Combined Heat &Power (CHP) is the simultaneousproduction and use of electricity andheat energy to provide high energyefficiencies (> 80%)
Efficiency can be further boosted(~90%) by adding an absorptionchiller to form a Tri-generation unitor Combined Cooling, Heat & Power(CCHP)
![Page 72: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/72.jpg)
Typical components of a CHP / CCHP
University of Adelaide 74
Source: Adapted from CIBSE, UK CHP Group
Natural gas / LPG / Diesel / Biomass / Waste Oil etc
Turbine / Reciprocating Engine
Grade of heat recovered
![Page 73: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/73.jpg)
Value proposition of CHP / CCHP
University of Adelaide 75
If sized and used appropriately, CHP / CCHP can deliver:
• Reduced energy costs – extract more value from input fuel • Reduced network costs – peak demand management• Improved energy security – island mode (may not be for
whole site)• Improved environmental footprint – depending on choice of
input fuel• Semi-dispatchable power plant – user controlled and not
depended on intermittent sources
![Page 74: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/74.jpg)
UoA Trigen Systems
University of Adelaide 76
Plant Accelerator Building (2009)
• 3 x 65kWe micro-turbinescoupled with an absorptionchiller as first stage
• High efficiency chillers &condensing boilers as support
• Operating 24/7 – serving theplant growth rooms
![Page 75: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/75.jpg)
UoA Trigen Systems
University of Adelaide 77
Ingkarni Wardli Building (2010)
• 337kWe reciprocating gas engine coupled with an absorption chiller as primary
• High efficiency electric chiller as secondary (or backup)
• Further enhanced by geo-thermal cooling and cooling tower heat recovery
![Page 76: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/76.jpg)
Potentials pitfalls of CHP / CCHP
• Under utilisation due to changes to business operations– Staged system can provide some flexibility, but can add upfront cost
– Shared system (Industrial Parks)
• Grid connection complexity and cost – Early engagement SAPN can save a lot $$$ downstream
• Variation to supply / price of input fuel
– Multi-fuel system can provide flexibility, but comes at a cost
University of Adelaide 78
![Page 77: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/77.jpg)
Heat Recovery
Opportunities:
• Boiler flue losses and blowdowns
• Cooling Towers
• Air compressors
• Ventilation systems
• Heat stored in products leaving the process
• Heat in cooling hydraulic oil systems
• Heat emitted by Data Centres / Communication rooms
University of Adelaide 79
![Page 78: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/78.jpg)
Heat Recovery
Economics:
• Understand quantity and quality of waste heat
• Identify heat demands in your facility and assess if these can be met directly (or as pre-heat)
• Identify if supply & demand are coincident, as adding storage can prove costly
University of Adelaide 80
![Page 79: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/79.jpg)
Example: air-compressor heat recovery
University of Adelaide 81
Source: Atlas Copco, Sweden
Applications
Domestic hot water
Space Heating
Product Drying
It is there for the taking!
![Page 80: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/80.jpg)
Microgrids, Storage and Smart Technologies
Topic -
![Page 81: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/81.jpg)
Agenda
• Overview
• Establishing Microgrids
• Energy Storage Systems
• Benefits for Early Adopters
University of Adelaide 83
![Page 82: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/82.jpg)
SA Power prices compared to OECD
University of Adelaide 84
Source: Carbon + Energy Markets (CME), 2017
![Page 83: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/83.jpg)
0.00
5.00
10.00
15.00
20.00
25.00
30.00
0
10
20
30
40
50
60
Ave
rage
wei
ghte
d r
ate
(ce
nts
/kW
h)
Tota
l co
nsu
mp
tio
n (
kWh
/ye
ar)
Mill
ion
s
Year
TOTAL (kWh) AVERAGE WEIGHTED RATE (c/kWh)
UoA 20 year electricity & cost trend
NEM commencement
150% increase in unit rate (2008 – 2018)
![Page 84: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/84.jpg)
Traditional centralised electricity supply model
University of Adelaide 86
Source: Adopted from the US Dept of Energy
![Page 85: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/85.jpg)
Rapid disruption to the centralised model
University of Adelaide 87
Source: Energy Networks Association, Australia
![Page 86: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/86.jpg)
Understanding your load profile
University of Adelaide 88
![Page 87: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/87.jpg)
Load Duration Curve
University of Adelaide 89
![Page 88: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/88.jpg)
Role of energy storage
University of Adelaide 90
Source: Adopted from the US Dept of Energy
‘Firming up & Grid Stabilisation’ ‘Energy Price Arbitrage, Demand Management & Security’
![Page 89: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/89.jpg)
Is it the right time to invest in storage?Lithium-ion battery pack ($/kWh)
University of Adelaide 91
Source: Deutsche Bank, 2018
![Page 90: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/90.jpg)
Batteries are not the only storage solutions
University of Adelaide 92
Source: University of Birmingham, Energy Storage Centre
Optimal choice of storage technology depends on end nature of application, criticality, risk appetite and overall business case
![Page 91: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/91.jpg)
Microgrid
University of Adelaide 93
A microgrid can be defined as a distributed power system with the ability to self-supply, manage, and operate with or without the main utility grid as required (US Dept of Energy, 2016)
![Page 92: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/92.jpg)
Typical architecture of a microgrid
University of Adelaide 94
Source: Reilly, Cleveland OH, Grid of the Future, 2017
![Page 93: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/93.jpg)
Microgrid management system
University of Adelaide 95
Source: Dashboard, Siemens Australia 2018
![Page 94: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/94.jpg)
Microgrid Ownership Structures
University of Adelaide 96
Source: WBCSD, Microgrid for C&I customers, 2017
![Page 95: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/95.jpg)
UoA Roseworthy Project (commenced)
University of Adelaide 97
• 1.2MW Solar PV farm
• 500kW / 2000kWh vanadium flow battery
• Partial campus microgrid
![Page 96: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/96.jpg)
Benefits
- Demand Management (and hence lower network costs)
- Reduced electricity cost (load shift during high price event)
- Island mode (increased resilience & faster recovery)
- Lower carbon footprint (depending on choice of DERs)
- Increased cybersecurity (for defence sector)
University of Adelaide 98
![Page 97: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/97.jpg)
Early Adopters – Risk versus Reward
• Potential risk
– Higher upfront cost
– Technical issues and disruptions
– Microgrid standardisation still under works
• Potential rewards
– Possible grants from various government agencies
– Potential cost subsidisation from Tier 1 suppliers to demonstrate proof-of-concept as well as gain market leadership
– Easier network connections due to interest and will from grid operators to learn from pilot projects
– Improved energy security and price fluctuations
University of Adelaide 99
![Page 98: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/98.jpg)
THANK YOU
University of Adelaide 100
Vikram Kenjle
Energy Manager - The University of Adelaide
Email: [email protected]
Tel: (08) 8313 5556
![Page 99: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/99.jpg)
![Page 100: Energy Efficiency Masterclass for IndustrySetting the Scene Industry and Energy Efficiency ... Danfoss VLT® Drives have peak voltage and rise ... estimates the dv/dt and Vpeak at](https://reader031.fdocuments.in/reader031/viewer/2022042005/5e6f497399e3a138e4437135/html5/thumbnails/100.jpg)
Thank You for AttendingPlease ensure you have filled in the evaluation form and
leave face down on the table.