ENER.G50 Technical Data Sheet

1
5 GENERAL DESCRIPTION: - Enclosure Type: Internal - Fuel Type: Natural Gas - Minimum Methane Number: 80 - Electrical Output: 51 kW - Heat Output (Exhaust Temp Cooled to120°C): 78 kW - Fuel Input Net/Gross (CV 10 kWh/Nm³): 163/180 kW - Min/Max Dynamic Gas Pressure: 20/45 mbar - Max Flow/Return Water Temp: 90/80°C PRIME MOVER: - Type: Reciprocating Engine - Combustion Cycle: 4-stroke Spark Ignition - Cylinders: 4 - Speed: 1500 rpm - Nox Emissions with/without Cat: 250/6500 mg/Nm³ - CO Emissions with/without Cat: 350/6500 mg/Nm³ - Aspiration: Natural GENERATOR: - Type: Synchronous - Frequency: 50 Hz - Voltage: 400 V - Efficiency: 92.6 % HEAT RECOVERY SYSTEM: - Fully closed primary water circuit - Exhaust gas heat exchanger in primary circuit - PHE between primary & secondary circuits - Primary water pump - Auto heat output modulation CONTROL & PROTECTION: - On board computer control, protection and monitoring - Engine stop/start, synchronising, modulation - Mechanical, electrical and thermal protection - 70+ parameters monitored, historical data recorded - 2 way communication between unit and head office - BMS interface signals STANDARD EQUIPMENT: - Exhaust silencers (industrial & residential grade) - Secondary water pump OPTIONAL EQUIPMENT / CONFIGURATION: - Heat rejection equipment / controls - Export control panel - Heat and gas metering - Modbus Interface Card - Catalytic converters for very low emissions - Generator only (no heat recovery) - Island mode operation - CHP absorption chiller packages - Noise levels stated are free field. - Electrical output is based on output at the generator terminals at a power factor of 0.95. - Energy quantities subject to reduction when modulating in response to external conditions. - We reserve the right to alter the Engine Type, at any time, to meet the system specifications. - Performance figures are subject to original Engine manufacturer's declared performance, tolerances and test conditions. - Technical Datasheets are subject to change, without notice, due to out commitment to ongoing product improvement. ENER·G Combined power Limited are part of the ENER·G Group. Issued: 26/07/2010 ENER·G House, Daniel Adamson Road, Manchester M50 1DT - T: 00 44 161 745 7450 E: [email protected] W: www.energ.co.uk ENERG 50M (Integral to Unit) ENER-G 50M Technical Datasheet

description

ASDAS

Transcript of ENER.G50 Technical Data Sheet

  • 50M

    GENERAL DESCRIPTION:

    - Enclosure Type: Internal

    - Fuel Type: Natural Gas

    - Minimum Methane Number: 80

    - Electrical Output: 51 kW

    - Heat Output (Exhaust Temp Cooled to120C): 78 kW

    - Fuel Input Net/Gross (CV 10 kWh/Nm): 163/180 kW

    - Min/Max Dynamic Gas Pressure: 20/45 mbar

    - Max Flow/Return Water Temp: 90/80C

    PRIME MOVER:

    - Type: Reciprocating Engine

    - Combustion Cycle: 4-stroke Spark Ignition

    - Cylinders: 4

    - Speed: 1500 rpm

    - Nox Emissions with/without Cat: 250/6500 mg/Nm

    - CO Emissions with/without Cat: 350/6500 mg/Nm

    - Aspiration: Natural

    GENERATOR:

    - Type: Synchronous

    - Frequency: 50 Hz

    - Voltage: 400 V

    - Efficiency: 92.6 %

    HEAT RECOVERY SYSTEM:

    - Fully closed primary water circuit

    - Exhaust gas heat exchanger in primary circuit

    - PHE between primary & secondary circuits

    - Primary water pump

    - Auto heat output modulation

    CONTROL & PROTECTION:

    - On board computer control, protection and monitoring

    - Engine stop/start, synchronising, modulation

    - Mechanical, electrical and thermal protection

    - 70+ parameters monitored, historical data recorded

    - 2 way communication between unit and head office

    - BMS interface signals

    STANDARD EQUIPMENT:

    - Exhaust silencers (industrial & residential grade)

    - Secondary water pump

    OPTIONAL EQUIPMENT / CONFIGURATION:

    - Heat rejection equipment / controls

    - Export control panel

    - Heat and gas metering

    - Modbus Interface Card

    - Catalytic converters for very low emissions

    - Generator only (no heat recovery)

    - Island mode operation

    - CHP absorption chiller packages

    - Noise levels stated are free field.

    - Electrical output is based on output at the generator terminals at a power factor of 0.95.

    - Energy quantities subject to reduction when modulating in response to external conditions.

    - We reserve the right to alter the Engine Type, at any time, to meet the system specifications.

    - Performance figures are subject to original Engine manufacturer's declared performance, tolerances and test conditions.

    - Technical Datasheets are subject to change, without notice, due to out commitment to ongoing product improvement.

    ENERG Combined power Limited are part of the ENERG Group.

    Issued: 26/07/2010 ENERG House, Daniel Adamson Road, Manchester M50 1DT - T: 00 44 161 745 7450 E: [email protected] W: www.energ.co.uk