1
Endian4i Edge Series
Endian 4i Edge Series
GETTING STARTED
-
8/9/2019 Endian Guidebook 4i-Screen
2/21
32
Endian4i Edge SeriesContents
Contents4i Edge 200 Hardware 4
4i Edge 300 Hardware 64i Edge 500 Hardware 8
4i Edge 500 Regulatory Compliance 104i Edge Series Specifications 12Quick Start 14
What you have and what you need 14
Mounting the 4i Edge device 15
Connecting the 4i Edge device 15
Installation 16
Web interface 17
Choose your Internet Connection Mode 17
Network settings 18
Endian Network Account 19
How to get Support 21Support case workflow 21
Maintenance Advantage 22Whats Included with Endian Maintenance? 22
4i Maintenance 24
Tips to Use your Endian 4i 24Update your Endian 4i Appliance 24
How to connect to the Console 25
What if you dont remember your password? 26
What if you dont remember the GREEN interface IP address? 27
What you can do with the Serial Console! 27
Factory reset 28
Software Update 28
Software Release Upgrade 29
Endian end user license agreement 30
Follow the Documentation on: http://docs.endian.com/
-
8/9/2019 Endian Guidebook 4i-Screen
3/21
54
Endian4i Edge Series4i Edge 200 Hardware
4i Edge 200 Hardware
Ethernet Activity LedmicroSD Slot Hard Disk Activity LedPower Led Power Supply Ethernet 10/100/1000 (RJ-45)USB Console
-
8/9/2019 Endian Guidebook 4i-Screen
4/21
76
Endian4i Edge Series4i Edge 300 Hardware
4i Edge 300 Hardware24V power input
USB
Serial Console
Ethernet 10/100 (RJ-45)
Rail mounting
Hard Disk Activity Led
Hard Disk Activity Led
-
8/9/2019 Endian Guidebook 4i-Screen
5/21
98
Endian4i Edge Series4i Edge 500 Hardware
4i Edge 500 Hardware
Edge 500
Ethernet 2 x 10/100 Mbps
12 - 48VDC Redundant Input
USB
Serial Console
Serial Console
Rail mounting
-
8/9/2019 Endian Guidebook 4i-Screen
6/21
1110
Endian4i Edge Series4i Edge 500 Regulatory Compliance
4i Edge 500 Regulatory Compliance
Safety UL508UL60950-1
EN60950-1
IEC60950-1
EMS EN61000-6-2EN61000-4-2 (ESD standards)
Contact: +/- 6 KV; criteria B
Air: +/- 8 KV; criteria B
EN61000-4-3 (radiated RFI standards)
10V/m, 80 to 1000 MHz; 80% AM criteria A
EN61000-4-4 (burst standards) Signal ports: +/- 2 KV; criteria B
DC power ports: +/- 2 KV; criteria B
EN61000-4-5 (surge standards) Signal ports: +/- 1 KV; line-to-line; criteria B
DC power ports: +/- 0.5 KV; line-to-earth; criteria B EN61000-
4-6 (induced RFI standards) Signal ports: 10 Vrms @ 0.15 ~ 80 MHz; 80% AM criteria A
DC power ports: 10 Vrms @ 0.15 ~ 80 MHz; 80% AM criteria
A EN61000-4-8 (magnetic field standards)
30 A/m @ 50, 60 Hz; criteria A
EMI FCC part 15, class AEN61000-6-4
EN55022
EN61000-3-2
EN61000-3-3
Environmental Test IEC60068-2-6 Fc (vibration resistance) 5 g @ 10 ~ 150 Hz,
amplitude 0.35 mm (operation/storage/transport)
IEC60068-2-27 Ea (shock) 25 g @ 11 ms (half-sine shock
pulse; operation); 50 g @ 11 ms (half-sine shock pulse; sto-
rage/transport)
IEC60068-2-32 Ed (free fall) 1 M (3.281ft)
-
8/9/2019 Endian Guidebook 4i-Screen
7/21
1312
Endian4i Edge Series4i Edge Series Specifications
4i Edge Series Specifications
4i Edge 200 4i Edge 300 4i Edge 500
CPU ARM (SoC) 1.2GHz AMD LX800 AMD LX800
Memory 512 MB 256 MB 512MB DDR 400 (Wide Temperature)
Ethernet 5x 10/100/1000 Mbps 4 x 10 /100 Mbps 2 x 10/100 Mbps
Storage 512 MB (Onboard) / 4 GB (MicroSD) 1GB Flash 4GB Compact Flash (Wide Temperature)
Console 1 RJ-45 (Serial) 1 x RS232 (Serial) 1 x RS232 (Serial)
USB Ports 1 2 2
Power External 12V 1.25A External 24V DC 12 - 48VDC Redundant Input
DIN-Rail Mountable - Yes Yes
Cooling Fanless Fanless Fanless
Dimension 37mm x 175mm x 175mm 45mm x 214mm x 150mm 81mm x 110mm x 135mm
Weight 1 kg 1,6 kg 1.38kg / 172kg (Net / Gross)
Housing Extruded Aluminum Extruded Aluminum Extruded Aluminum & Heavy-Duty Steel
Operating Temp 0 C to + 40 C (+32 F to +105 F) 0 C to + 40 C (+32 F to +105 F) -40 C to +70 C (-40 F to +158 F)
Storage Temp 0 C to + 40 C (+32 F to +105 F) 0 C to + 40 C (+32 F to +105 F) -45 C to +85 C (-49 F to +185 F)
Humidity 5% - 95% 5% - 95% 5% - 95%
Hardware Warranty 36 Months 36 Months 36 Months
-
8/9/2019 Endian Guidebook 4i-Screen
8/21
1514
Endian4i Edge SeriesQuick Start
Quick Start
What you have and what you need
With your 4i Edge box you receive:
4i 200:
AC Adaptor + AC Plug (EU, US, AU, UK)
Serial Cable (DB9 female to RJ45)
RJ45 twisted pair cable
4i 300:
RJ45 twisted pair cable
Serial Cable (female to female)
AC Plug (green, 3 pin) 4i 500:
RJ45 twisted pair cable
Serial Cable (female to female)
AC Plug (green, 8 pin)
To connect and operate your 4i Edge you need:
Power socket
Ethernet switch (connected to your network) DIN Rails (4i Edge 300 and 500 only)
Mounting the 4i Edge device
4i Edge 200:
Place your 4i Edge device on a steady surface Power cable
4i Edge 300 and 500:
mount rail adapters
mount 4i Edge on the rails
Connecting the 4i Edge device1. Plug the ethernet cable in to a switch or hub using a standard patch cable
2. Plug the serial console cable into a remote console server (optional)
3. Plug in the AC power cable to the AC power socket
-
8/9/2019 Endian Guidebook 4i-Screen
9/21
1716
Endian4i Edge SeriesQuick Start
Web interface1. Configure your PC Ethernet interface with an IP address belonging to the
192.168.0.0/24 subnet that is different from 192.168.0.15 (4i Edge IP
address)2. Open your Internet browser (e.g. Mozilla Firefox) and go to address
192.168.0.15
The system will redirect you tohttps://192.168.0.15:10443/and
ask you for your preferred language, and your time zone. After that you
need to accept the license agreement.
The system will now ask you to choose 2 passwords (admin for webin-
terface and root for console).
Choose your Internet Connection Mode1. Now its time to configure your Internet access:
Ethernet Static or DHCP (if your firewall is directly connected to theInternet, for example to a router or modem)
PPPoE
ADSL or ISDN (if you are using a DSL/ISDN modem)
Analog / UMTS modem
Gateway (use only if you dont need the WAN interface)
Installation
Warning! The default IP address of the Endian Appliance GREEN
interface (port 1) is 192.168.0.15. Make sure there is no othermachine with this address in your network; should you have such
a machine, turn it off or disconnect it from the switch during the
installation and initial configuration of your Endian Appliance.
You can find step-by-step HOWTOs to set up your 4i Edge deviceon the website http://endian.zendesk.com/forums/
-
8/9/2019 Endian Guidebook 4i-Screen
10/21
1918
Endian4i Edge SeriesQuick Start
REDexternal network (WAN). Usually this is the interface connected to
the Internet.
BLUEwireless network. This kind of network is usually not as safe as awired one.
ORANGEnetwork for servers connected to the Internet (DMZ). It is
meant for the servers that have to provide services on RED(Internet). This
way, even if the security of one of these servers has been compromised,
the GREENarea will remain safe.
2. Choose your configuration and assign network interfaces to every zone (select
one or more network interfaces for each zone). Follow all the wizard steps to
configure Endian Appliance and protect your network.
Endian Network AccountTo activate your Endian Network subscription and keep your Endian
Appliance always up-to-date with the latest features and security
updates follow these steps:
A. If you already have an Endian Network Account
1. When the system asks you if you have an Endian Network account
choose yes and go to the next step.
Network settings1. Every network zone is assigned to a colour:
GREENlocal network (LAN). This is the safe area where your trusted
computers are located.
-
8/9/2019 Endian Guidebook 4i-Screen
11/21
2120
Endian4i Edge SeriesHow to get Support
How to get SupportSupport for your 4i Edge device includes:
Endian Network subscription
Software updates and upgrades
Technical support
3 years full replacement warranty
Support case workflowContact your Endian Partner
Check: http://docs.endian.com/
Check: http://help.endian.com/
open a ticket request on: http://help.endian.com/
2. Now fill in the form using your data and the activation key (see the label
on the back of this Guidebook).
B. If you dont have an Endian Network Account
1. When the system asks you if you have an Endian Network account
choose no and go to the next step.
2. Click on the Endian Network account link (https://network.endian.com/
register.php) and insert the activation key (see the label on the back of this
Guidebook).
3.Fill in the registration form and create your account.
4. Close the registration window and go to the next step.
5. Now fill in the form using your data and the activation key.
Your Endian 4i Appliance is now ready!
-
8/9/2019 Endian Guidebook 4i-Screen
12/21
2322
Endian4i Edge SeriesMaintenance Advantage
Endian Upgrades
Why is Endian Appliance the best open source 4i on the market? Its simple,
were always looking to make our product better and enhance the functionality
of our software whether its through our own development or utilizing the power
of the Endian (and open source) community! With Endian Maintenance, you get
each and every upgrade and improvement we make to our product and Endian
Network makes the deployment to your device(s) as simple as point-and-click.
Endian Support
Endian Support is comprised of the best and brightest Endian support engineers
who are devoted to supporting the rapidly growing number of Endian 4i Appli-
ances all over the world. We offer a broad range of support options that range
from a basic support package to our premium support services that
include direct phone assistance as well as remote live assistance from an
Endian support engineer.
Maintenance AdvantageWhats Included with Endian Maintenance?
Endian Network
The Endian Network is a centralized portal to monitor and manage all of
your Endian Firewall devices. If one of you Endian 4i Appliance devices has
hardware or software service issues, Endian Network will alert you so you can
react fast and mitigate issues before they cause significant problems. A great
tool for Endian resellers as well since it also allows you to completely manage
user administration and determine Endian Network access you (as a reseller)
provide to your customers.
Endian Updates
Keep your Endian 4i Appliance devices as up-to-date as possible to keep your
networks and users protected from modern day threats. This includes all Endian
security services like antivirus, intrusion detection signatures, and URL blacklists
(content filtering). Just as importantly, Endian maintenance includes all security
updates to every Endian application so that you can keep the devices protect-
ing your network safe from security vulnerabilities.
-
8/9/2019 Endian Guidebook 4i-Screen
13/21
2524
Endian4i Edge SeriesTips to Use your Endian 4i
4i Maintenance
Endian offers highly qualified support services that come along with all
our security solutions, being included in the Maintenance subscription.Distributors and Partners get support directly from Endian while end us-
ers receive assistance through one of our worldwide Partners, according
to the Maintenance and Support SLA.
Advanced Maintenance is designed for companies that require a high pri-
ority level of support. This package includes quickreaction support service that
guarantees the lowest downtime impact on your network in case of problems or
hardware failure.
Tips to Use your Endian 4iUpdate your Endian 4i Appliance By web interface: System gUpdates
Just click on Check for new updates!, and click on Start update process NOW!
By console:
Log into your firewall by SSH
run the command smart update && smart upgrade
How to connect to the ConsoleRequirements:
1. a serial null modem cable
2. a workstation with serial interface
3. a terminal program
Connect the serial nullmodem cable to the console port of your Endian 4i and the
other end to your workstations serial port (COM1).
Use a terminal program (Minicom for Unix/Linux, PuTTY for Windows) in order to
connect to the Firewall. The necessary parameters are:
115200 baud
8 bit
No parity bit
1 stop bit
After successfully connect, if the firewall is up and running, you should find a menu.
-
8/9/2019 Endian Guidebook 4i-Screen
14/21
2726
Endian4i Edge SeriesTips to Use your Endian 4i
What if you dont remember your password?
If you forgot the Web admin password:
but you remember the ROOT Console password connect to the serial console
and choose the Change Admin Password (Option #3) from the menu
If you forgot the ROOT console password:
but you remember the Web admin password you can set a new ROOT
password from the web interface using the System -> Password menu
If you forgot BOTH admin and root passwords:
For security reasons, resetting the password is not permitted. You can restore
the factory default setting using the serial console by choosing Restore
Factory Defaults (Option #4) from the menu (look at the documentation on
www.endian.com, for more help on using the serial console)
What if you dont remember the GREEN interface IPaddress?
By console:
the console menu will show you the management URL and the Green IP address
(look at the documentation on www.endian.com for more help on using the
serial console)
What you can do with the Serial Console! use the bash shell (choosing the Option #0). You will need the root password
restore to factory defaults status
reboot the system
change your web or console passwords
-
8/9/2019 Endian Guidebook 4i-Screen
15/21
2928
Endian4i Edge SeriesTips to Use your Endian 4i
IMPORTANT
Endian updates will never be applied automatically to your 4i device.
Trough the Web Interface or the Endian Network you can update at the most
appropriate time for you.
Software Release Upgrade
As Endian Maintenance customer your are entitled to upgrade your software to the
next release.
This service is part of your initial Maintenance package you can extend your main-
tenance option by purchasing additional one or three year maintenance.
IMPORTANT
Endian version upgrades will never be applied automatically to your 4i device.
Trough Endian Network you have the option to upgrade at the time that is most
appropriate for you.
Factory reset
In case you wish to reset your 4i Edge device to factory settings you have 2 options:
1) Web Interface go to Menubar -> System -> Backup , scroll down to the box
Reset configuration to factory defaults and reboot
then click on factory defaults
This option will wipe out all configurations and settings done so far
and automatically reboot the system with the default configuration.
2) Serial Console
Connect via serial console then choose the option restore to factory defaults
Your root password will be required.
The system will automatically reboot with the default configuration.
Software Update
Software updates include security updates and bugfixes for packages in your current
Software release. Endian will release security enhancement and bugfixes whenever
available.
E di 4i Ed S i
-
8/9/2019 Endian Guidebook 4i-Screen
16/21
3130
Endian4i Edge SeriesEndian end user license agreement
Endian end user license agreementBY USING THE ENDIAN PRODUCT, YOU AGREE TO BE BOUND BY THE TERMS OF THIS
AGREEMENT. IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT, YOU MAY
NOT USE THE ENDIAN PRODUCT NOR ANY OTHER SOFTWARE LICENSED UNDER THISAGREEMENT, AND YOU MAY RETURN THE UNUSED ENDIAN PRODUCT TO THE VENDOR
FROM WHICH YOU ACQUIRED IT WITHIN THIRTY (30) DAYS FOR A FULL REFUND.
Article 1 - Definitions
1.1 You shall mean the natural person or the entity that is agreeing to be bound by this
Agreement, their employees and third party contractors that provide services to you.
YOU SHALL BE LIABLE FOR ANY FAILURE BY SUCH EMPLOYEES AND THIRD PARTY
CONTRACTORS TO COMPLY WITH THE TERMS OF THIS AGREEMENT.
1.2 ENDIAN Shall mean Endian s.r.l., a corporation organized under the laws of Italy,
whose registered office is at Appiano (BZ), Bergweg 41 (via Monte), I-39057, Italy,
Tax code IT02472130216-
1.3 ENDIAN Product: Shall mean t he ENDIAN software or hardware/software product(s)
purchased by You through an authorized ENDIAN distributor or reseller.
1.4 Copyleft License: Shall mean any software license which grants any recipient of the
software the right to copy, modify and redistribute modified versions of the software, but
provided that all copies and modified versions are distributed under the same terms and
conditions provided in the Copyleft License it self.
1.5 Copyleft Software: Shall mean any software covered by any Copyleft License and
included in or provided with the ENDIAN Product.
1.6 Copyleft Source Code: Shall mean the source code corresponding to the binaries for
the Copyleft Software.
1.7 Software: Shall mean all software and/or firmware (including its Graphical UserInterface and any accompanying documentation) included in (or otherwise provided to
You with) the ENDIAN Product and any updates and maintenance releases there to, with
the exception of Copyleft Software.
1.8 Hardware: Shall mean the hardware part (where present) of the ENDIAN Product,
with exclusion of Software and of Copyleft Software.
1.9 Business Use: Shall mean use of the Software by business entities (including profes-
sionals) which independently carry out the supply of goods and services, whatever the
purpose or results of such economic activities, with express exclusion of private use by
consumers.
1.10 Users: Shall mean all users in the computer network which is protected and/or man-
aged through the ENDIAN Product, including without limitation workstations, clients,
servers and devices that communicate through the ENDIAN Product to reach the Internet,as well as VPN connections from remote VPN clients or from remote VPN gateways
(each remote gateway counts as one user).
1.11 ENDIAN Network: Shall mean ENDIANs software and database facilities for inte-
grated Customer Relationship, Support and Service Management.
E di 4i Ed S i
-
8/9/2019 Endian Guidebook 4i-Screen
17/21
3332
Endian4i Edge SeriesEndian end user license agreement
1.12 Applicable Additional License Terms: Shall mean any possible additional license terms
applicable to the specific ENDIAN Product purchased by You, where enclosed with this
Agreement.
Article 2 - License Grant
2.1 Whereas. ENDIAN provides network security services through ENDIAN Network
(hereinafter, ENDIAN Services), which You can access and use only through ENDIAN
Product. The license provided in this Article 2 is granted to You in order to enable You to
use ENDIAN Services.
2.2 License. Subject to the terms of this Agreement, to the Applicable Additional License
Terms, and to proper and ongoing payment of the applicable service and maintenance
fees, ENDIAN hereby grants You a non-exclusive, non-transferable license, without rights
to sublicense, to use the Software only for Business Use.
2.3 Registration. You shall register Your ENDIAN Product with ENDIAN Network within thirty
days from its first boot. Should you fail to register within such deadline, terminal remote
access to ENDIAN Product, web management interface and hotspot functionality will be
temporarily disabled until You register Your ENDIAN Product. During such temporary dis-
abling of the above- mentioned features, all other functionalities of ENDIAN Product willnot be compromised, and ENDIAN Product will keep performing its functions (except for
hotspot functionality), even if it will not be possible to change its configuration through
web interface or terminal remote access, but only by editing internal configuration files.
The above-mentioned limitations shall apply also in case You fail to renew maintenance
services within thirty days from t heir expiration.
2.4 License Limitations. You may not copy the Software except for a reasonable number of
machine-readable copies of the Software for backup or archival purposes. You may
not remove any titles, trademarks or trade names, copyright notices, legends, or other
proprietary markings on the Software. You are not granted any rights to any trademarks
or service marks of ENDIAN. ENDIAN retains all rights not expressly granted to You.
2.5 Restrictions. You may not (i) sell, lease, license, sublicense, distribute or otherwise trans-
fer in whole or in part the Software to another party; (ii) provide, disclose, divulge or
make available to, or permit use of the Software in whole or in part by, any third party
without ENDIANs prior written consent; or (iii) modify or create derivative works based
upon the Software. Except to the extent expressly permitted by applicable law, and to
the extent that ENDIAN is not permitted by that applicable law to exclude or limit the
following rights, you may not decompile, disassemble, reverse engineer, or otherwise
attempt to derive source code from the Software, in whole or in part. For the sake of
clarity, these Restrictions do not apply to any Copyleft Software or any part of the Endian
Product (but only those parts) which are under a copyright license that permit otherwise.
2.6 Number of Users. You acknowledge and accept that the number of Users may be
monitored by ENDIAN through ENDIAN Network. If the number of Users exceed the
maximum possibly provided by the Applicable Additional License Terms, ENDIAN
may suspend any support and maintenance services by disabling access to ENDIAN
Network, with 30 days prior notice, unless You upgrade Your license to the new number
of Users within 30 days from receipt of ENDIANs notice. During the period of time from
when the number of users has been exceeded to when the deficiency has been cured,
ENDIAN shall have no responsibility for malfunctioning or lack of upgrades, unless in
the event that ENDIAN acted with malicious intent or gross negligence.
Endian 4i Edge Series
-
8/9/2019 Endian Guidebook 4i-Screen
18/21
3534
Endian4i Edge SeriesEndian end user license agreement
2.7 Copyleft Software. You can redistribute and/or modify the Copyleft Software under the
terms of the applicable Copyleft Licenses. For the sake of clarity, nothing in this license
shall have the effect to reduce or deprive You of any of the rights or liberties granted by
the relevant Copyleft License. You may obtain a copy of the Copyleft Source Code by
downloading the source files from ENDIANs Web site at http://www.endian.com/it/
community/download/, or by sending a request, with your name and address, to EN-DIAN at the address specified in section 1.2, in which case ENDIAN will mail a copy of
the Copyleft Source Code to you on a CD or equivalent physical medium reserving the
right to demand payment of reasonable shipping and storage expenses before shipping
the copy of the Copyleft Source Code. This offer to obtain a copy of the Copyleft Source
Code is valid for three years from the date you acquired this Software product.
Article 3 - Support and Maintenance
3.1 Support and Maintenance Services. Subject to proper and ongoing payment of the
applicable service and maintenance fees, ENDIAN will provide to You support and
maintenance services under the Service Level Agreement posted on ENDIANs Web site
at http://www.endian.com/en/support/maint enance/ and by accepting the terms of
this Agreement you are accepting such Service Level Agreement.
3.2 Supplemental Software. Any supplemental software or related materials that ENDIANprovides to you as part of any support and maintenance services (except for supplemen-
tal software covered by Copyleft Licenses) are to be considered part of the Software
and are subject to the terms and conditions of this Agreement.
Article 4 - Term and Termination
4.1 Term. Except for evaluation and beta licenses, where the term is limited according to
the Applicable Additional License Terms, the term of the license is for the duration of
ENDIANs copyright in the Software.
4.2 Termination. ENDIAN may terminate this Agreement immediately and without notice ifYou fail to comply with any term of this Agreement.
4.3 Effect of Termination. In the event of termination, You must destroy all copies of the
Software, including all backup copies, and remove it from all computers and terminals
on which it is installed. The provisions of this Agreement, except for the license granted
in Section 2 (License Grant) but including section 2.7 (Copyleft Software), shall
survive termination.
Article 5 - Limited Warranty and Limitation of Liability
5.1 Limited Warranty. ENDIAN warrants that Hardware, if any, is free of defects in design,
materials and workmanship that materially affect their performance for a period of 1 year,
provided that You may extend such warranty period according to the terms posted on EN-
DIANs Web site at http://www.endian.com/en/company/legals-and-policies/. ENDIANs
sole obligation shall be to repair or replace the defective Hardware at no charge to You. EN-DIAN may replace the defective Hardware (or any part thereof) even with a different model
or part, either new or reconditioned, provided that the replacement hardware is substantially
equivalent or superior in all material respects to the defective Hardware. Such obligation
is exclusive of transport fees, installation costs and any other costs which are not directly
associated with the product. Hardware repair or replacement shall be carried out according
to the then-current ENDIANs Warranty and RMA Procedures, posted on ENDIANs Web
Endian 4i Edge Series
-
8/9/2019 Endian Guidebook 4i-Screen
19/21
3736
Endian4i Edge SeriesEndian end user license agreement
site at http://www.endian.com/en/company/legals-and-policies/. Software and Copyleft
Software is licensed on a AS IS basis, without warranties or conditions of any kind, either
express or implied. ENDIAN shall be responsible only for willful acts and gross negligence
with respect to damages caused by any ENDIAN Products. THE LIMITED WARRANTIES
SET FORTH ABOVE ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, BY
STATUTE OR OTHERWISE, ALL OF WHICH ARE HEREBY DISCLAIMED AND EXCLUDED BYENDIAN, INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE OR USE AND ALL OBLIGATIONS OR LIABILI-
TIES ON THE PART OF ENDIAN FOR DAMAGES ARISING OUT OF OR IN CONNECTION
WITH THE USE, REPAIR OR PERFORMANCE OF THE PRODUCTS.
5.2 Excluded Claims. ENDIAN shall have no obligation under any warranty in the event that:
5.2.1 repair or replacement of any ENDIAN Product shall have been required by
normal wear and tear or necessitated in whole or in part by events attributable to
force majeure or the negligence of any party other than ENDIAN;
5.2.2 the ENDIAN Product has been modified in any manner without prior written
consent of ENDIAN, except for the configuration available and intended to be
made through the interfaces of the ENDIAN Product;
5.2.3 the ENDIAN Product has not been maintained or used in accordance withENDIANs applicable operating and/or maintenance manuals;
5.2.4 damages or defects result from improper handling and/or non-usage of the
original packing and the applicable packing instruction.
5.3 Modifications to ENDIAN Products. Without first obtaining the written approval from
ENDIAN, You shall not make (nor allow any other third party to make) any modifications
to any ENDIAN Products or any parts of Products, other than installing ENDIANs official
Software/Firmware updates. Notwithstanding the foregoing provision, any modification
rights, which are granted by Copyleft Licenses of Copyleft Software, may be always
exercised by any recipient of such software, but in such case ENDIAN shall not haveany warranty or support obligations with respect to such modified ENDIAN Products and
all fees for already purchased support and maintenance services shall remain due.
5.4 Cryptographic Software Notice. Some Copyleft Software may include cryptographic software.
The country in which You currently reside may have restrictions on the import, possession, use,
and/or re-export to another country, of cryptographic software. BEFORE using any crypto-
graphic software, please check your countrys laws, regulations and policies concerning the
import, possession, or use, and re-export of encryption software, to see if this is permitted.
5.5 Data Retention, Anti-Terrorism, You acknowledge that use of ENDIAN Products, first
and foremost when used to provide services to the public and/or third parties, may be
subject to legal restrictions provided by Data Retention Laws, Anti-Terrorism Acts and
similar laws, statutes or regulations applicable in Your country. Such restrictions may
significantly vary depending on the context of use and other circumstances. It is your
sole responsibility to use and configure ENDIAN Products in order to comply with such
laws, statutes or regulations. Any legal texts and/or disclaimers possibly displayed or
otherwise provided by and/or included in ENDIAN Products are exemplary texts pro-
vided on a courtesy basis, without warranties or conditions of any kind, either express
or implied, and it is your sole responsibility to modify such texts or substitute them with
other appropriate texts depending on the context of use and on the laws and regulations
applicable in Your country.
Endian 4i Edge Series
-
8/9/2019 Endian Guidebook 4i-Screen
20/21
3938
Endian4i Edge SeriesEndian end user license agreement
Standard Conformance
This device is CE and FCC-certified and meets European and US health, safety, and
environmental standards.
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in
a commercial environment. This equipment generates, uses, and can radiate radio fre-
quency energy and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense
Contains FCC ID:PPD-AR5BXB92 (WiFi Model Only)
Disposal of the device
This device is subject to European Directive 2002/96/EC and may not be disposedof with general household garbage. If you do not know where you may dispose of the
device at the end of its lifespan, contact your municipality, your local waste management
provider, or your seller.
Article 6 - General Provisions
6.1 Entire Agreement. This Agreement sets forth ENDIANs entire liability and your exclusive
remedy with respect to the ENDIAN Product and supersedes the terms of any purchase
orders and any other communications or advertising with respect to the Software. You
acknowledge that this Agreement is a complete statement of the agreement between youand ENDIAN with respect to the ENDIAN Product, and that there are no other prior or
contemporaneous understandings, promises, representations, or descriptions with respect
to the ENDIAN Product.
6.2 Waiver and Modification. No failure of either party to exercise or enforce any of its
rights under this Agreement will act as a waiver of those rights. This Agreement may only
be modified, or any rights under it waived, by a written document executed by the party
against which it is asserted.
6.3 Severability. If any provision of this Agreement is found void or unenforceable, it will be
enforced to the maximum extent permissible, and the legality and enforceability of the
other provisions of this Agreement will not be affected.
6.4 Governing Law and Jurisdiction. This Agreement and any legal matters that may
arise out of or in connection with this Agreement shall be subject to, and construed
exclusively in accordance with the laws of the Republic of Austria, except for its of laws
provisions (Internationales Privatrecht) and without application of the Convention on
the International Sales of Goods (Wiener Kaufrechtsbereinkommen). The courts of
Bolzano, Italy, shall have exclusive jurisdiction.
-
8/9/2019 Endian Guidebook 4i-Screen
21/21
40
EndianUnified Network SecurityEndian end user license agreement
www.endian.com
2012 Endian SRL. Subject to change without notice. Endian and Endian Firewall aretrademarks of Endian SRL. All other trademarks and registered trademarks are the propertyof their respective owners.