enclosures to ATEX and enclosures for special custom ... · Worldwide availability without delays....

16
R enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets) Stainless steel and plastic enclosures for use in potentially explosive environments

Transcript of enclosures to ATEX and enclosures for special custom ... · Worldwide availability without delays....

Page 1: enclosures to ATEX and enclosures for special custom ... · Worldwide availability without delays. International approvals and certification. Faster + better + cost-effective: That

R

enclosures to ATEX and enclosures

for special custom design (EEx p and NEMA cabinets)

S t a i n l e s s s t e e l a n d

p l a s t i c e n c l o s u r e s f o r u s e

i n p o t e n t i a l l y e x p l o s i v e

e n v i r o n m e n t s

Page 2: enclosures to ATEX and enclosures for special custom ... · Worldwide availability without delays. International approvals and certification. Faster + better + cost-effective: That

Rittal – system partnersPerfect comprehensive solutions

2 Rittal Ex enclosures to ATEX

The demands placed on Ex enclosures are particularly

high. For this reason, Rittal accepts no compromises, and

adapts tried and tested enclosure concepts to meet the

specific requirements of potentially explosive environments.

The result is a series of Ex enclosures providing ideal

conditions for applications in the chemicals and petro-

chemicals industries, in the offshore sector and in the foods

industry.

The added value of our integral solutionsEnclosures for every application in numerous sizes and designs.

Fast, cost-effective system integration through comprehensive accessories.

High product quality ensuring reliability.

Worldwide availability without delays.

International approvals and certification.

Faster + better + cost-effective: That is the formula for a modular configuration concept and individual Rittal solutions. Ex enclosures to ATEX

satisfy approval criteria to the fullZone 1 and 2 to EN 50 014 and EN 50 019.

Zone 21 and 22 to EN 50 281.

Partial certification to ATEX 100a (EC Directive 94/9/EC).

Ambient operating temperature: Maximum: +80 °C Minimum: –20 °C (–40 °C on request)

Protection category: With IP 56 or IP 66 to EN 60 529, the required level of protection is reliably exceeded.

Constantly high quality is guaranteed by production and routine testing procedures with ISO 9001 certification.

Perfect response to special demandsWorldwide implementation of explosion protection is based essentially on the European standards.

Special approvals for the American market – to Class I, Zone I acc. to NEC – upon request.

Practically all Rittal enclosure systems can also be prepared for pressurisation to EN 50 016 upon request.

Further dimensions and versions upon request, also to meet individual certification requirements.(NEMA 4, NEMA 4x, IP65)

Page 3: enclosures to ATEX and enclosures for special custom ... · Worldwide availability without delays. International approvals and certification. Faster + better + cost-effective: That

Ex enclosures

Rittal Ex enclosures to ATEX 3

Plastic Ex enclosure with hinged door Type Examination Certificate No. PTB 03 ATEX 1011U (for empty enclosures KEL)PTB 03 ATEX 1012 (for terminal enclosures KE)

For wall mounting: 4 press-fit screw bushes M8.

Double seal at top and bottom edges of the door through additional integrated rain protection strip.

Enclosure can be rotated to switch door hinging to the other side.

Door opening angle 180°.

Double-bit insert in the lock, exchangeable for other lock inserts.

Manufactured in fibre-glass-reinforced, unsaturated polyester with a high graphite content: Surface resistance: < 109 Ohm.

Stainless steel Ex enclosure with hinged door Type Examination Certificate No. PTB 02 ATEX 1082U (for empty enclosures KEL)PTB 02 ATEX 1083(for terminal enclosures KE)

For wall mounting: 4 blind rivet nuts M8.

To discharge possible static charges: Blind rivet nut M8 on the outside.

Door is simple to remove when open.

Double-bit insert in the cam lock, exchangeable for other lock inserts.

Mounting plate both sides with pitch pattern for easier configuration.

PE conductor connection in enclosure and door.

Stainless steel Ex enclosure with screw fastened lid Type Examination Certificate No. PTB 03 ATEX 1013U (for empty enclosures KEL)PTB 03 ATEX 1014 (for terminal enclosures KE)

For wall mounting: 4 blind rivet nuts M8.

To discharge possible static charges: Blind rivet nut M8 on the outside.

For simple attachment of support rails or mounting plates in the enclosure: Profile strips with mounting holes on both sides.

PE conductor connection in enclosure and cover.

Captive-mounted cover attachment.

Three enclosure types to meet differing demandsThe enclosures in this brochure are approved for use in potentially explosive atmospheres attributable to gases and/or dusts.

Our own accredited laboratories and the latest manufacturing technologies, paired with comprehensive quality management, guarantee constantly high standards worldwide.

Page 4: enclosures to ATEX and enclosures for special custom ... · Worldwide availability without delays. International approvals and certification. Faster + better + cost-effective: That

Stainless steel Ex enclosures

4 Rittal Ex enclosures to ATEX

With screw fastened lid

Material:Stainless steel 1.4301/1.4404 (304/316L)

Surface finish:Brushed

Protection category:IP 66 to EN 60 529/10.91

Certificates: PTB 03 ATEX 1013U (for empty enclosures KEL)PTB 03 ATEX 1014 (for terminal enclosures KE)

Supply includes:Enclosure, lid with all-round foamed-in PU seal.

With hinged door

Material:Stainless steel 1.4301/1.4404(304/316L)Mounting plate: Sheet steel

Surface finish:Brushed Mounting plate: Zinc-plated

Protection category:IP 66 to EN 60 529/10.91

Certificates: PTB 02 ATEX 1082U (for empty enclosures KEL)PTB 02 ATEX 1083 (for terminal enclosures KE)

Supply includes:Enclosure, door with all-round foamed-in PU seal, mounting plate.

Wall brackets for enclosure attachment of the series KE/KEL 9301.600 – 9306.600.

Material:Stainless steel 1.4301/1.4404*

Wall brackets for enclosure attachment of the series KE/KEL 9401.600 – 9409.600.

Material:Stainless steel 1.4301/1.4404*

Packs of Model No. KL

4 1594.000

4 on request*

Packs of Model No. SZ

4 2433.000

4 2433.500*

EMC concept on request.

Page 5: enclosures to ATEX and enclosures for special custom ... · Worldwide availability without delays. International approvals and certification. Faster + better + cost-effective: That

5Rittal Ex enclosures to ATEX

B4

B6

B3

M8

x 20

50B5

H1

B1

20

44

20

79.515.5H

4

H3

H2

15

120

44

H3

H2

H4

15

80

39.5

15.5

2020

2.5

B3

B5

2.5

100

B6

B1

50

32

100

37.

5

H1

20

2020

H4

T1

H2

2.5

H3

2.5

30

50

Ø 9

138

225

6.5

275

260

162

122

122

9

12.5

F1

18.5

23.

5

F2

8.2

6.6

G1

42.

5

F2

14.

5

1

KEL 9301.000 – KEL 9306.000: with screw fastened lid

KEL 9301.000 – KEL 9306.000: with screw fastened lid

KEL 9401.600 – KEL 9409.600: with hinged door

B1 Width mm

H1 Height mm

T1 Depth mm

Packs of B3 B4 B5 B6 H2 H3 H4

Dimensions of mounting plate Weight

(kg)Model No.

KEL

Accessories: Mounting plates KLG1 F1 F2

150 150 80 1 132 109 125 148 148 132 100 135 125 – 1.3 9301.000 1560.700

200 200 80 1 182 159 175 198 198 182 150 185 175 50 1.8 9303.000 1562.700

300 150 80 1 282 259 275 298 148 132 100 285 125 – 1.8 9302.000 1561.700

300 200 80 1 282 259 275 298 198 182 150 285 175 50 2.4 9304.000 1563.700

300 300 120 1 282 259 275 298 298 282 250 285 275 50 3.9 9306.000 1567.700

400 200 120 1 382 359 375 398 198 182 150 385 175 50 3.6 9305.000 1564.700

To order Ex enclosures in 1.4404 (AISI 316L), change the last three digits of the Model No. to .500.

B1 Width mm

H1 Height mm

T1 Depth mm

Packs of B3 B5 B6 H2 H3 H4

Dimensions of mounting plate No. of fasteners

Weight (kg)

Model No. KELG1 G2 F1 F2

200 300 155 1 167 122 – 295 274 260 – – – – 1 3.8 9401.600

300 380 210 1 260 250 175 375 340 295 275 250 334 295 1 7.7 9409.600

380 300 155 1 340 295 255 295 260 250 275 250 334 295 1 7.4 9402.600

380 380 210 1 340 295 255 375 340 330 355 330 334 295 1 9.7 9403.600

380 600 210 1 340 295 255 595 560 545 570 545 334 295 2 13.3 9404.600

600 600 210 1 560 510 475 595 560 545 570 545 549 510 2 15.6 9405.600

600 760 210 1 560 510 475 755 720 705 730 705 549 510 2 22.3 9406.600

760 760 300 1 720 665 635 755 720 705 730 705 704 665 2 30.5 9407.600

800 1000 300 1 760 700 675 995 960 930 955 930 739 700 2 36.3 9408.600

To order Ex enclosures in 1.4404 (AISI 316L), change the last three digits of the Model No. to .500.

1

2

G2

10

90

F1

F2

G1

Mounting plate

= only attaching in the centre for 125 mm wide plates

1

KEL 9401.600 – KEL 9409.600: with hinged door Mounting plate KEL 9401.600

Mounting plate KEL 9402.600 – KEL 9408.600

= Only for KEL 9408.6001 = 20 for KEL 9409.6002

Installation position of the mounting plate is rotated through 90° for KEL 9409.600.

Page 6: enclosures to ATEX and enclosures for special custom ... · Worldwide availability without delays. International approvals and certification. Faster + better + cost-effective: That

Ex enclosuresStainless steel enclosures with screw fastened lid

6 Rittal Ex enclosures to ATEX

KEL 9301.000 empty enclosuresEx II 2 G EEx e II

KE 9301.000 terminal enclosuresEx II 2 G EEx e ia II C T6 or T5

Wall mountingSee page 4.

Max. number of screwed cable glands

Equipment of terminal enclosure KE 9301.000Max. number of cables depending on the cross-section and the permissible permanent current.

KEL 9302.000 empty enclosuresEx II 2 G EEx e II

KE 9302.000 terminal enclosuresEx II 2 G EEx e ia II C T6 or T5

Wall mountingSee page 4.

Max. number of screwed cable glands

Equipment of terminal enclosure KE 9302.000Max. number of cables depending on the cross-section and the permissible permanent current.

KEL 9303.000 empty enclosuresEx II 2 G EEx e II

KE 9303.000 terminal enclosuresEx II 2 G EEx e ia II C T6 or T5

Wall mountingSee page 4.

Max. number of screwed cable glands

Equipment of terminal enclosure KE 9303.000Max. number of cables depending on the cross-section and the permissible permanent current.

Size A B C D

M12 x 1.5 4 2 4 4

M16 x 1.5 3 1 3 3

M20 x 1.5 3 1 3 3

M25 x 1.5 – – 2 2

M32 x 1.5 – – 2 2

M40 x 1.5 – – – –

M50 x 1.5 – – – –

M63 x 1.5 – – – –

Current in A

Cross-section in mm2

1.5 2.5 4 6 10

10 43

16 15 29 112

20 6 17 32

25 8 18 35

35 5 14 34

50 2 11

63 3

80

100

125

Max. number of terminals 18 18 18 13 11

Size A B C D

M12 x 1.5 4 2 11 11

M16 x 1.5 3 1 10 10

M20 x 1.5 3 1 8 8

M25 x 1.5 – – 7 7

M32 x 1.5 – – 5 5

M40 x 1.5 – – – –

M50 x 1.5 – – – –

M63 x 1.5 – – – –

Current in A

Cross-section in mm2

1.5 2.5 4 6 10

10 48

16 16 32 124

20 6 18 36

25 8 20 39

35 6 15 38

50 2 12

63 4

80

100

125

Max. number of terminals 47 47 44 33 27

Size A B C D

M12 x 1.5 6 4 6 6

M16 x 1.5 5 3 5 5

M20 x 1.5 4 2 4 4

M25 x 1.5 – – 4 4

M32 x 1.5 – – 3 3

M40 x 1.5 – – – –

M50 x 1.5 – – – –

M63 x 1.5 – – – –

Current in A

Cross-section in mm2

1.5 2.5 4 6 10

10 50

16 17 33 131

20 7 19 38

25 9 21 41

35 6 16 40

50 2 13

63 4

80

100

125

Max. number of terminals 57 57 28 21 17

Page 7: enclosures to ATEX and enclosures for special custom ... · Worldwide availability without delays. International approvals and certification. Faster + better + cost-effective: That

Stainless steel enclosures with screw fastened lid

Ex enclosures

7Rittal Ex enclosures to ATEX

KEL 9304.000 empty enclosuresEx II 2 G EEx e II

KE 9304.000 terminal enclosuresEx II 2 G EEx e ia II C T6 or T5

Wall mountingSee page 4.

Max. number of screwed cable glands

Equipment of terminal enclosure KE 9304.000Max. number of cables depending on the cross-section and the permissible permanent current.

KEL 9305.000 empty enclosuresEx II 2 G EEx e II

KE 9305.000 terminal enclosuresEx II 2 G EEx e ia II C T6 or T5

Wall mountingSee page 4.

Max. number of screwed cable glands

Equipment of terminal enclosure KE 9305.000Max. number of cables depending on the cross-section and the permissible permanent current.

KEL 9306.000 empty enclosuresEx II 2 G EEx e II

KE 9306.000 terminal enclosuresEx II 2 G EEx e ia II C T6 or T5

Wall mountingSee page 4.

Max. number of screwed cable glands

Equipment of terminal enclosure KE 9306.000Max. number of cables depending on the cross-section and the permissible permanent current.

Size A B C D

M12 x 1.5 6 4 11 11

M16 x 1.5 5 3 10 10

M20 x 1.5 4 2 8 8

M25 x 1.5 – – 7 7

M32 x 1.5 – – 5 5

M40 x 1.5 – – – –

M50 x 1.5 – – – –

M63 x 1.5 – – – –

Current in A

Cross-section in mm2

1.5 2.5 4 6 10

10 55

16 19 36 143

20 7 21 41

25 10 23 45

35 6 17 44

50 2 14

63 4

80

100

125

Max. number of terminals 89 89 48 36 29

Size A B C D

M12 x 1.5 18 16 48 48

M16 x 1.5 9 7 41 41

M20 x 1.5 8 6 22 22

M25 x 1.5 7 5 19 19

M32 x 1.5 3 1 13 13

M40 x 1.5 2 – 6 6

M50 x 1.5 2 – 5 5

M63 x 1.5 – – – –

Current in A

Cross-section in mm2

1.5 2.5 4 6 10 16 25 35

10 68

16 23 45 175

20 9 26 51

25 12 29 55

35 8 21 54

50 3 17 44

63 6 20 73

80 8 23 82

100 10 21

125 8

Max. number of terminals 118 118 59 44 35 30 24 24

Size A B C D

M12 x 1.5 33 31 33 33

M16 x 1.5 19 17 29 29

M20 x 1.5 16 14 16 16

M25 x 1.5 13 11 13 13

M32 x 1.5 4 2 9 9

M40 x 1.5 3 1 3 3

M50 x 1.5 2 1 2 2

M63 x 1.5 – – – –

Current in A

Cross-section in mm2

1.5 2.5 4 6 10 16 25 35

10 76

16 26 50 197

20 10 29 57

25 14 32 62

35 9 24 60

50 3 19 50

63 6 23 82

80 9 26 92

100 11 24

125 9

Max. number of terminals 129 129 43 32 26 21 17 17

Page 8: enclosures to ATEX and enclosures for special custom ... · Worldwide availability without delays. International approvals and certification. Faster + better + cost-effective: That

Ex enclosuresStainless steel enclosures with hinged door

8 Rittal Ex enclosures to ATEX

KEL 9401.600 empty enclosuresEx II 2 G EEx e II

KE 9401.600 terminal enclosuresEx II 2 G EEx e ia II C T6 or T5

Wall mountingSee page 4.

Max. number of screwed cable glands

Equipment of terminal enclosure KE 9401.600Max. number of cables depending on the cross-section and the permissible permanent current.

KEL 9402.600 empty enclosuresEx II 2 G EEx e II

KE 9402.600 terminal enclosuresEx II 2 G EEx e ia II C T6 or T5

Wall mountingSee page 4.

Max. number of screwed cable glands

Equipment of terminal enclosure KE 9402.600Max. number of cables depending on the cross-section and the permissible permanent current.

KEL 9409.600 empty enclosuresEx II 2 G EEx e II

KE 9409.600 terminal enclosuresEx II 2 G EEx e ia II C T6 or T5

Wall mountingSee page 4.

Max. number of screwed cable glands

Equipment of terminal enclosure KE 9409.600Max. number of cables depending on the cross-section and the permissible permanent current.

Size A B C D

M12 x 1.5 60 54 40 40

M16 x 1.5 44 40 28 28

M20 x 1.5 36 32 24 24

M25 x 1.5 23 20 14 14

M32 x 1.5 11 10 7 7

M40 x 1.5 10 8 6 6

M50 x 1.5 8 7 6 6

M63 x 1.5 – – – –

Current in A

Cross-section in mm2

1.5 2.5 4 6 10 16

10 77

16 26 51 198

20 11 30 57

25 14 32 62

35 9 24 61

50 3 20 50

63 6 23

80 9

100

125

Max. number of terminals 40 40 40 30 24 20

Size A B C D

M12 x 1.5 60 54 80 80

M16 x 1.5 44 41 60 60

M20 x 1.5 36 32 48 48

M25 x 1.5 24 21 30 30

M32 x 1.5 12 10 16 16

M40 x 1.5 10 8 12 12

M50 x 1.5 8 6 9 9

M63 x 1.5 3 2 4 4

Current in A

Cross-section in mm2

1.5 2.5 4 6 10 16 25 35

10 91

16 31 60 236

20 13 35 68

25 16 38 74

35 11 29 72

50 4 23 60

63 8 28 99

80 10 31 111

100 13 29

125 11

Max. number of terminals 77 77 77 58 46 39 31 31

Size A B C D

M12 x 1.5 128 124 96 96

M16 x 1.5 102 99 77 77

M20 x 1.5 72 68 54 54

M25 x 1.5 50 48 40 40

M32 x 1.5 32 30 24 24

M40 x 1.5 18 17 15 15

M50 x 1.5 10 9 8 8

M63 x 1.5 8 7 6 6

Current in A

Cross-section in mm2

1.5 2.5 4 6 10 16 25 35

10 107

16 36 71 276

20 15 41 80

25 19 45 87

35 13 34 85

50 5 27 70

63 9 32 116

80 12 36 130

100 15 34

125 13

Max. number of terminals 77 77 77 58 46 39 31 31

Page 9: enclosures to ATEX and enclosures for special custom ... · Worldwide availability without delays. International approvals and certification. Faster + better + cost-effective: That

Stainless steel enclosures with hinged door

Ex enclosures

9Rittal Ex enclosures to ATEX

KEL 9403.600 empty enclosuresEx II 2 G EEx e II

KE 9403.600 terminal enclosuresEx II 2 G EEx e ia II C T6 or T5

Wall mountingSee page 4.

Max. number of screwed cable glands

Equipment of terminal enclosure KE 9403.600Max. number of cables depending on the cross-section and the permissible permanent current.

KEL 9404.600 empty enclosuresEx II 2 G EEx e II

KE 9404.600 terminal enclosuresEx II 2 G EEx e ia II C T6 or T5

Wall mountingSee page 4.

Max. number of screwed cable glands

Equipment of terminal enclosure KE 9404.600Max. number of cables depending on the cross-section and the permissible permanent current.

KEL 9405.600 empty enclosuresEx II 2 G EEx e II

KE 9405.600 terminal enclosuresEx II 2 G EEx e ia II C T6 or T5

Wall mountingSee page 4.

Max. number of screwed cable glands

Equipment of terminal enclosure KE 9405.600Max. number of cables depending on the cross-section and the permissible permanent current.

Size A B C D

M12 x 1.5 128 122 128 128

M16 x 1.5 105 101 105 105

M20 x 1.5 72 67 72 72

M25 x 1.5 48 46 48 48

M32 x 1.5 30 28 30 30

M40 x 1.5 18 15 18 18

M50 x 1.5 10 8 10 10

M63 x 1.5 8 7 8 8

Current in A

Cross-section in mm2

1.5 2.5 4 6 10 16 25 35

10 114

16 39 76 294

20 16 44 85

25 21 48 93

35 14 36 90

50 5 29 75

63 10 35 123

80 13 38 138

100 16 36

125 16

Max. number of terminals 102 102 102 77 62 52 41 41

Size A B C D

M12 x 1.5 216 208 128 128

M16 x 1.5 161 156 98 98

M20 x 1.5 114 108 72 72

M25 x 1.5 80 77 50 50

M32 x 1.5 48 46 32 32

M40 x 1.5 30 28 18 18

M50 x 1.5 16 14 10 10

M63 x 1.5 14 12 8 8

Current in A

Cross-section in mm2

1.5 2.5 4 6 10 16 25 35

10 123

16 42 82 318

20 17 48 92

25 22 52 100

35 15 39 98

50 5 32 81

63 10 37 133

80 14 42 149

100 18 39

125 16

Max. number of terminals 172 172 172 130 104 87 70 70

Size A B C D

M12 x 1.5 216 208 216 216

M16 x 1.5 161 155 161 161

M20 x 1.5 114 108 114 114

M25 x 1.5 80 77 80 80

M32 x 1.5 48 46 48 48

M40 x 1.5 30 28 30 30

M50 x 1.5 16 14 16 16

M63 x 1.5 14 12 14 14

Current in A

Cross-section in mm2

1.5 2.5 4 6 10 16 25 35

10 145

16 50 97 375

20 20 56 109

25 27 62 119

35 18 46 115

50 6 37 95

63 12 44 157

80 17 49 176

100 21 46

125 2 19

Max. number of terminals 258 258 258 195 157 131 105 105

Page 10: enclosures to ATEX and enclosures for special custom ... · Worldwide availability without delays. International approvals and certification. Faster + better + cost-effective: That

Ex enclosuresStainless steel enclosures with hinged door

10 Rittal Ex enclosures to ATEX

KEL 9406.600 empty enclosuresEx II 2 G EEx e II

KE 9406.600 terminal enclosuresEx II 2 G EEx e ia II C T6 or T5

Wall mountingSee page 4.

Max. number of screwed cable glands

Equipment of terminal enclosure KE 9406.600Max. number of cables depending on the cross-section and the permissible permanent current.

KEL 9407.600 empty enclosuresEx II 2 G EEx e II

KE 9407.600 terminal enclosuresEx II 2 G EEx e ia II C T6 or T5

Wall mountingSee page 4.

Max. number of screwed cable glands

Equipment of terminal enclosure KE 9407.600Max. number of cables depending on the cross-section and the permissible permanent current.

KEL 9408.600 empty enclosuresEx II 2 G EEx e II

KE 9408.600 terminal enclosuresEx II 2 G EEx e ia II C T6 or T5

Wall mountingSee page 4.

Max. number of screwed cable glands

Equipment of terminal enclosure KE 9408.600Max. number of cables depending on the cross-section and the permissible permanent current.

Size A B C D

M12 x 1.5 272 264 216 216

M16 x 1.5 210 205 161 161

M20 x 1.5 150 144 114 114

M25 x 1.5 100 97 80 80

M32 x 1.5 64 62 48 48

M40 x 1.5 39 37 30 30

M50 x 1.5 22 20 16 16

M63 x 1.5 18 16 14 14

Current in A

Cross-section in mm2

1.5 2.5 4 6 10 16 25 35

10 154

16 53 103 399

20 22 60 116

25 28 65 126

35 19 49 123

50 7 40 101

63 13 47 167

80 18 52 187

100 22 49

125 2 20

Max. number of terminals 335 335 335 253 204 170 136 136

Size A B C D

M12 x 1.5 408 402 408 408

M16 x 1.5 330 324 330 330

M20 x 1.5 225 219 225 225

M25 x 1.5 156 151 156 156

M32 x 1.5 94 91 94 94

M40 x 1.5 76 73 76 76

M50 x 1.5 44 42 44 44

M63 x 1.5 27 25 27 27

Current in A

Cross-section in mm2

1.5 2.5 4 6 10 16 25 35

10 194

16 66 129 501

20 27 75 145

25 36 82 158

35 24 62 154

50 9 50 127

63 7 59 210

80 23 66 235

100 28 62

125 3 25

Max. number of terminals 335 335 335 253 204 170 136 136

Size A B C D

M12 x 1.5 552 544 432 432

M16 x 1.5 429 423 341 341

M20 x 1.5 324 320 252 252

M25 x 1.5 189 189 154 154

M32 x 1.5 126 124 108 108

M40 x 1.5 83 81 68 68

M50 x 1.5 56 54 44 44

M63 x 1.5 35 34 27 27

Current in A

Cross-section in mm2

1.5 2.5 4 6 10 16 25 35

10 211

16 72 140 545

20 30 82 158

25 39 90 172

35 26 67 168

50 10 55 139

63 18 64 229

80 25 71 256

100 31 67

125 3 27

Max. number of terminals 444 444 444 336 270 225 181 181

Page 11: enclosures to ATEX and enclosures for special custom ... · Worldwide availability without delays. International approvals and certification. Faster + better + cost-effective: That

Plastic Ex enclosures with hinged door

11Rittal Ex enclosures to ATEX

KS 1423.600 and KS 1432.600 with only one cam lock in the centreModel No. B1 B2 B3 B4 B5 B7 B8 H1 H2 H3 H5 H6 H7 T1 T3 T4 m1 m2 m3 F1 G1

KEL 9201.600 200 140 150 – 100 150 25 300 280 256 200 245 250 150 80 – 110/117 119 2,0 3,0 3,0 145 250

KEL 9202.600 250 190 200 75 150 200 50 350 330 306 250 295 300 150 80 – 110/117 119 2,0 3,0 3,0 195 300

KEL 9203.600 300 240 249 100 200 250 50 400 380 355 300 345 350 200 80 – 160/167 169 2,0 3,0 3,0 245 350

KEL 9204.600 400 340 348 200 300 350 100 400 380 354 300 345 350 200 80 – 159/166 168,5 2,5 3,2 3,2 345 350

KEL 9205.600 400 340 348 200 300 350 100 600 580 554 500 545 550 200 80 – 158/165 168 2,5 3,5 3,5 345 550

KEL 9206.600 600 540 548 400 500 550 200 600 580 554 500 545 550 200 80 – 158/165 168 2,5 3,5 3,5 545 550

KEL 9207.600 500 440 434 300 400 450 150 500 480 454 400 445 450 300 80 – 258/265 268 2,5 3,5 3,5 417 450

Model No. B1 B2 B3 B4 B5 B7 H1 H2 H3 H5 H6 H7 m2 m3 G1 F1

KEL 9208.600 600 485 533 400 500 550 800 780 753 700 740 750 3,7 3,7 750 517

KEL 9209.600 800 685 733 600 700 750 1000 980 953 900 940 950 3,7 4,0 950 717

B452

B2

B7

B1

B3

B5

H3

100

H6

H5

4.5

H2

H1

H7

25

T1

m1

m2

3

T4

T3

12.5

42.5

42.5

12.5

12.5G

1

10

50

10.

5

F1

16

60

10.5

8.5

B8

3

m3

17.5 B7 = Separation width for wall mounting holeH7 = Separation height for wall mounting hole

Mounting plate

Inside view of door

Only KEL 9201.600

and KEL 9202.600

Material:Enclosure: Fibre-glass-reinforced unsaturated polyesterSurface resistance: < 103 ΩMounting plate: Sheet steel, zinc-plated, passivated

Colour:RAL 9011

Protection category:IP 66 to EN 60 529/10.91KEL 9209.600:IP 56 to EN 60 529/10.91

Certificates: PTB 03 ATEX 1011U (for empty enclosures KEL)PTB 03 ATEX 102 (for terminal enclosures KE)

Supply includes:Enclosure, door with all-round foamed-in PU seal, mounting plate.

Wall brackets for safe enclosure attachment of the series KE/KEL 9201.600 – 9209.600. Colour similar to RAL 9011.

Material:Durethan

Packs of Model No. KE

4 9266.000

Page 12: enclosures to ATEX and enclosures for special custom ... · Worldwide availability without delays. International approvals and certification. Faster + better + cost-effective: That

Ex enclosuresPlastic enclosures with hinged door

12 Rittal Ex enclosures to ATEX

KEL 9201.600 empty enclosuresEx II 2 G EEx e II

KE 9201.600 terminal enclosuresEx II 2 G EEx e ia II C T6 or T5

Wall mountingSee page 11.

Max. number of screwed cable glands

Equipment of terminal enclosure KE 9201.600Max. number of cables depending on the cross-section and the permissible permanent current.

KEL 9202.600 empty enclosuresEx II 2 G EEx e II

KE 9202.600 terminal enclosuresEx II 2 G EEx e ia II C T6 or T5

Wall mountingSee page 11.

Max. number of screwed cable glands

Equipment of terminal enclosure KE 9202.600Max. number of cables depending on the cross-section and the permissible permanent current.

KEL 9203.600 empty enclosuresEx II 2 G EEx e II

KE 9203.600 terminal enclosuresEx II 2 G EEx e ia II C T6 or T5

Wall mountingSee page 11.

Max. number of screwed cable glands

Equipment of terminal enclosure KE 9203.600Max. number of cables depending on the cross-section and the permissible permanent current.

Size A B C D

M12 x 1.5 24 24 24 24

M16 x 1.5 16 16 16 16

M20 x 1.5 4 4 8 8

M25 x 1.5 2 2 6 6

M32 x 1.5 2 2 2 2

M40 x 1.5 – – 2 2

M50 x 1.5 – – – –

M63 x 1.5 – – – –

Current in A

Cross-section in mm2

1.5 2.5 4 6 10 16

10 75

16 26 50 195

20 10 29 56

25 14 32 61

35 9 24 60

50 3 19 49

63 6 23

80 8

100

125

Max. number of terminals 40 40 40 30 24 20

Size A B C D

M12 x 1.5 32 32 32 32

M16 x 1.5 22 22 22 22

M20 x 1.5 8 8 12 12

M25 x 1.5 8 8 10 10

M32 x 1.5 2 2 4 4

M40 x 1.5 2 2 2 2

M50 x 1.5 2 2 2 2

M63 x 1.5 – – – –

Current in A

Cross-section in mm2

1.5 2.5 4 6 10 16 25 35

10 83

16 28 55 215

20 11 32 62

25 15 35 68

35 10 26 66

50 4 21 54

63 7 25 90

80 9 28 101

100 12 26

125 10

Max. number of terminals 44 44 44 33 27 22 18 18

Size A B C D

M12 x 1.5 60 60 60 60

M16 x 1.5 46 46 46 46

M20 x 1.5 24 24 32 32

M25 x 1.5 22 22 24 24

M32 x 1.5 12 12 12 12

M40 x 1.5 4 4 8 8

M50 x 1.5 4 4 4 4

M63 x 1.5 2 2 2 2

Current in A

Cross-section in mm2

1.5 2.5 4 6 10 16 25 35

10 105

16 36 69 270

20 15 40 78

25 19 44 85

35 13 33 83

50 5 27 69

63 9 32 113

80 12 35 127

100 15 33

125 13

Max. number of terminals 60 60 60 46 37 30 24 24

Page 13: enclosures to ATEX and enclosures for special custom ... · Worldwide availability without delays. International approvals and certification. Faster + better + cost-effective: That

Plastic enclosures with hinged door

Ex enclosures

13Rittal Ex enclosures to ATEX

KEL 9204.600 empty enclosuresEx II 2 G EEx e II

KE 9204.600 terminal enclosuresEx II 2 G EEx e ia II C T6 or T5

Wall mountingSee page 11.

Max. number of screwed cable glands

Equipment of terminal enclosure KE 9204.600Max. number of cables depending on the cross-section and the permissible permanent current.

KEL 9205.600 empty enclosuresEx II 2 G EEx e II

KE 9205.600 terminal enclosuresEx II 2 G EEx e ia II C T6 or T5

Wall mountingSee page 11.

Max. number of screwed cable glands

Equipment of terminal enclosure KE 9205.600Max. number of cables depending on the cross-section and the permissible permanent current.

KEL 9206.600 empty enclosuresEx II 2 G EEx e II

KE 9206.600 terminal enclosuresEx II 2 G EEx e ia II C T6 or T5

Wall mountingSee page 11.

Max. number of screwed cable glands

Equipment of terminal enclosure KE 9206.600Max. number of cables depending on the cross-section and the permissible permanent current.

Size A B C D

M12 x 1.5 60 60 96 96

M16 x 1.5 46 46 66 66

M20 x 1.5 24 24 40 40

M25 x 1.5 22 22 36 36

M32 x 1.5 12 12 24 24

M40 x 1.5 4 4 12 12

M50 x 1.5 4 4 8 8

M63 x 1.5 2 2 4 4

Current in A

Cross-section in mm2

1.5 2.5 4 6 10 16 25 35

10 114

16 39 76 294

20 16 44 85

25 21 48 93

35 14 36 90

50 5 29 75

63 10 35 123

80 13 38 138

100 16 36

125 14

Max. number of terminals 99 99 99 75 60 50 40 40

Size A B C D

M12 x 1.5 120 120 96 96

M16 x 1.5 82 82 62 62

M20 x 1.5 52 52 40 40

M25 x 1.5 39 39 35 35

M32 x 1.5 20 20 20 20

M40 x 1.5 10 10 10 10

M50 x 1.5 10 10 8 8

M63 x 1.5 4 4 4 4

Current in A

Cross-section in mm2

1.5 2.5 4 6 10 16 25 35

10 123

16 42 82 317

20 17 48 92

25 22 52 100

35 15 39 98

50 5 32 81

63 10 37 133

80 14 41 149

100 18 39

125 16

Max. number of terminals 172 172 172 130 104 87 70 70

Size A B C D

M12 x 1.5 120 120 156 156

M16 x 1.5 82 82 109 109

M20 x 1.5 52 52 72 72

M25 x 1.5 38 38 58 58

M32 x 1.5 18 18 32 32

M40 x 1.5 9 9 16 16

M50 x 1.5 9 9 12 12

M63 x 1.5 4 4 6 6

Current in A

Cross-section in mm2

1.5 2.5 4 6 10 16 25 35

10 142

16 49 95 368

20 20 55 107

25 26 60 116

35 18 45 113

50 6 37 94

63 12 43 154

80 16 48 173

100 20 45

125 2 18

Max. number of terminals 258 258 258 195 157 131 105 105

Page 14: enclosures to ATEX and enclosures for special custom ... · Worldwide availability without delays. International approvals and certification. Faster + better + cost-effective: That

Ex enclosuresPlastic enclosures with hinged door

14 Rittal Ex enclosures to ATEX

KEL 9207.600 empty enclosuresEx II 2 G EEx e II

KE 9207.600 terminal enclosuresEx II 2 G EEx e ia II C T6 or T5

Wall mountingSee page 11.

Max. number of screwed cable glands

Equipment of terminal enclosure KE 9207.600Max. number of cables depending on the cross-section and the permissible permanent current.

KEL 9208.600 empty enclosuresEx II 2 G EEx e II

KE 9208.600 terminal enclosuresEx II 2 G EEx e ia II C T6 or T5

Wall mountingSee page 11.

Max. number of screwed cable glands

Equipment of terminal enclosure KE 9208.600Max. number of cables depending on the cross-section and the permissible permanent current.

KEL 9209.600 empty enclosuresEx II 2 G EEx e II

KE 9209.600 terminal enclosuresEx II 2 G EEx e ia II C T6 or T5

Wall mountingSee page 11.

Max. number of screwed cable glands

Equipment of terminal enclosure KE 9209.600Max. number of cables depending on the cross-section and the permissible permanent current.

Size A B C D

M12 x 1.5 165 165 220 220

M16 x 1.5 120 120 152 152

M20 x 1.5 72 72 112 112

M25 x 1.5 55 55 91 91

M32 x 1.5 25 25 45 45

M40 x 1.5 15 15 32 32

M50 x 1.5 10 10 16 16

M63 x 1.5 7 7 10 10

Current in A

Cross-section in mm2

1.5 2.5 4 6 10 16 25 35

10 157

16 54 104 405

20 22 61 117

25 29 66 128

35 19 50 124

50 7 40 103

63 13 48 170

80 18 53 190

100 23 50

125 2 20

Max. number of terminals 197 197 197 149 120 100 80 80

Size A B C D

M12 x 1.5 308 308 286 286

M16 x 1.5 232 232 187 187

M20 x 1.5 152 152 144 144

M25 x 1.5 102 102 102 102

M32 x 1.5 54 54 54 54

M40 x 1.5 31 31 35 35

M50 x 1.5 17 17 21 21

M63 x 1.5 17 17 16 16

Current in A

Cross-section in mm2

1.5 2.5 4 6 10 16 25 35

10 181

16 62 121 468

20 26 70 136

25 33 77 148

35 22 58 144

50 8 47 119

63 16 55 197

80 21 61 220

100 26 58

125 2 23

Max. number of terminals 343 343 343 259 208 174 139 139

Size A B C D

M12 x 1.5 418 418 308 308

M16 x 1.5 290 290 222 222

M20 x 1.5 200 200 144 144

M25 x 1.5 144 144 102 102

M32 x 1.5 82 82 54 54

M40 x 1.5 46 46 36 36

M50 x 1.5 27 27 20 20

M63 x 1.5 22 22 16 16

Current in A

Cross-section in mm2

1.5 2.5 4 6 10 16 25 35

10 211

16 72 140 545

20 30 82 158

25 39 90 172

35 26 67 168

50 10 55 139

63 18 64 229

80 25 71 256

100 31 67

125 3 27

Max. number of terminals 444 444 444 336 270 225 181 181

Page 15: enclosures to ATEX and enclosures for special custom ... · Worldwide availability without delays. International approvals and certification. Faster + better + cost-effective: That

Prepared for Ex pressurisation or indoor and outdoor solutions

Baying systems TS 8 with side panel

15Rittal Ex enclosures to ATEX

Prepared for Ex pressurisation

Prepared for NEMA 4x, NEMA 4

Width mm 600 800 600 800 600 800 1000 600 800 600 –

Height mm 1400 1400 1600 1600 1800 1800 1800 1800 1800 1800 –

Depth mm 500 500 500 500 400 400 400 500 500 600 –

Model No. TS sheet steel 8645.660 8845.660 8665.660 8865.660 8684.660 8884.660 8084.660 8685.660 8885.660 8686.660 –

Width mm 800 600 800 600 800 600 800 600 800 600 800

Height mm 1800 2000 2000 2000 2000 2000 2000 2000 2000 2200 2200

Depth mm 600 400 400 500 500 600 600 800 800 600 600

Model No. TS sheet steel 8886.660 8604.660 8804.660 8605.660 8805.660 8606.660 8806.660 8608.660 8808.660 8626.660 8826.660

Width mm 800 1000 600 800 600 600 800 800 – – –

Height mm 1800 1800 1800 1800 1800 2000 2000 2000 – – –

Depth mm 400 400 500 500 600 600 600 800 – – –

Model No. TS stainless steel 8454.660 8461.660 8457.660 8455.660 8458.660 8452.660 8450.660 8460.660 – – –

Packs of NEMA 4x, stainless steel NEMA 4, sheet steel

Width mm 600 800 600 800 600 800 600 800

Height mm 1800 1800 2000 2000 1800 1800 2000 2000

Depth mm 600 600 600 600 600 600 600 600

Clearance width mm 512 712 512 712 512 712 512 712

Clearance height mm 1712 1712 1912 1912 1712 1712 1912 1912

Clearance depth mm 512 512 512 512 512 512 512 512

Door clearance available for installation 455 655 455 655 455 655 455 655

Door clearance available for installation 1630 1630 1830 1830 1630 1630 1830 1830

Mounting plate width 499 699 499 699 499 699 499 699

Mounting plate height 1696 1696 1896 1896 1696 1696 1896 1896

Model No. TS 1 8458.640 8459.640 8452.640 8450.640 8686.640 8886.640 8606.640 8806.640

Door 1 1 1 1 1 1 1 1

Design: Base as for roof Door with additional cams top

and bottom (only EEx p models)

Door r/h or l/h hinged on request

Front and back door on request

3 mm zinc-plated mounting plate (sheet steel)

Customer-specific design and solutions on request

Price and delivery times on request

Protection category:Complies with Nema 4, Nema 4x, IP 65

Material:Sheet steel, dipcoat primed and powder-coated on the outside in textured RAL 7035or stainless steel 1.4301 (AISI 304)or stainless steel 1.4401 (AISI 316L)

Page 16: enclosures to ATEX and enclosures for special custom ... · Worldwide availability without delays. International approvals and certification. Faster + better + cost-effective: That

R

Switch to perfection

Small enclosures Compact enclosures Large enclosuresPC enclosure and case systems Console systems Industrial Workstations Command Panel systems Support arm systems Stainless steel enclosures EMC-shielded enclosures Ex enclosures

All in all – solutions from Rittal

Rittal has one of the largest ranges of enclosures available for immediate delivery. However, Rittal also supplies integrated solutions – up to Level 4. This comprises mechanical installation, power supply, electronic components, climate control and central monitoring. For all

of your requirements. Fully assembled and functional. Wherever in the world you develop and implement solutions for yourself and your customers, we are close at hand. The global alliance between production, distribution and service guarantees closeness to the customer. Worldwide!

10/0

4 E

145

Electronic packaging

IT solutions

Communication systems

System climate control

Power distribution

Industrial enclosures

Rittal bv Hengelder 56 Postbus 246 6900 AE ZevenaarTel.: (0316) 591660 Fax: (0316) 525145 E-mail: [email protected] www.rittal.nl