Enabling Design Freedom - Fire & Safety Hometfppemea.com/en/_layouts/fsassets/Docs/Water Based...

4
Safer. Smarter. Tyco Window Sprinklers Enabling Design Freedom

Transcript of Enabling Design Freedom - Fire & Safety Hometfppemea.com/en/_layouts/fsassets/Docs/Water Based...

Safer. Smarter. Tyco

Window Sprinklers

Enabling Design Freedom

In all of today’s iconic buildings, glass is one of the major design elements used by architects.

Protecting buildings primarily made of glass against fire can be challenging for fire protection consultants and means many architects limit their designs, but thanks to Tyco Fire Protection Products innovative window sprinklers there is a solution where every floor can be considered as an independent fire sector, allowing building design to further evolve.

The success of the model WS Window Sprinkler is based on its fast response, thermal sensitivity and its specially designed deflector which ensures that the spray pattern wets the entire surface of the window. An important aspect of these sprinklers is that they are fitted with calculated spacing, which means they don’t comprise each other when they are activated.

Based on rigorous testing by the NFPA, the model WS Window Sprinkler has been approved for use with windows or glazing in all applications. During ASTM E119 tests windows protected by our window sprinklers where exposed to direct fire for more than two hours without showing any signs of damage.

Our sprinklers are used in some of the most widely recognized buildings. The Gas Natural building in Barcelona is recognized throughout the world and is an architectural masterpiece that is protected by the WS Series sprinklers. By using our sprinklers, the architect was free to create a futuristic design while still complying with safety requirements.

Model WS Specific Application Window

Sprinklers

FIRE PROTECTED

GLAZING

Enabling Design

Freedom

Photography - Peter Bennett

Although UL Listed, if there are additional local or jurisdictional installation standards/codes for window sprinklers on glazed windows systems, this approval dose not relieve the designer/installer from these requirements. Consult you local jurisdiction to verify if or when these additional guidelines must be followed.

Technical Data:

Advantages of the WS Series sprinklers• First sprinklers to be specifically listed to provide complete wetting

and coverage for heat strengthened or tempered glass windows

• Every floor within a building can be considered as an independent fire sector allowing more design freedom for Architects

• Fast response and thermal sensitivity preventing thermal shock of glass

Approvals• UL, C-UL and ULC Listed

• NYC under MEA 289-04-E Additional Recognition

• Ontario Building Code

TY3388 - Horizontal Sidewall

Connections: 1/2” NPT

Discharge Coefficient: K=80,6 LPM/ bar 1/2 5.6 GPM/psi 1/2

Temperature Ratings: 68°C (155°F) • 93°C (200°F)

Finish: Polyester Coated / Chrome Plated / Natural Brass

TY3388: Horizontal Sidewall

TY3488: Pendent Vertical Sidewall

Datasheet: For complete technical data refer to technical datasheet TFP620

TY3488 - Pendent Vertical Sidewall

WORLDWIDE HEADQUARTERSTyco Fire Protection Products, 1400 Pennbrook Parkway, Lansdale, PA 19446,Tel: +1 215-362-0700, (Toll Free) Tel: +1 800-558-5236, Fax: +1 800-877-1295 www.tyco-fire.com

SINGAPORETyco Fire Protection Products, 2 Serangoon North Avenue 5, #07-01, Singapore 554911 Tel. +65-6577-4360, Fax: +65-6481-8791www.tyco-fire.com

ENSCHEDEKopersteden 1, P.O. Box 198, 7500 AD Enschede, The Netherlands, Tel. +31 (0)53-428-4444www.tfppemea.com

www.tfppemea.com

Safer. Smarter. Tyco

Global Strength. Local expertise.At your service