EN60454-3-1.PDF

14
Test Report No. TSNEC1602189001 Date: 21 December, 2016 Page 1 of 14 ZHENGZHOU YOU TRUST TECH CO.,LTD ROOM09,5 FLOOR,UNIT2,BUILDING 13, NO.1 CHAOFENG ROAD, ZHENGZHOU ECONOMIC&TECHNICAL DISTRICT 450016 The following sample(s) was/ were submitted and identified on behalf of the client as: Sample Name : PVC TAPE SGS Ref. No. : TP16-009285 -TJ Date of sample received : 09 December, 2016 Testing Period : 09 December, 2016 to 21 December, 2016 Test result(s) : For further details, please refer to the following page(s) Signed for and on behalf of SGS-CSTC Standards Technical Services (Tianjin) Co., Ltd. ______________________ Reabeca Zhou Approved Signatory

Transcript of EN60454-3-1.PDF

Page 1: EN60454-3-1.PDF

Test Report No. TSNEC1602189001 Date: 21 December, 2016 Page 1 of 14

ZHENGZHOU YOU TRUST TECH CO.,LTD ROOM09,5 FLOOR,UNIT2,BUILDING 13, NO.1 CHAOFENG ROAD, ZHENGZHOU ECONOMIC&TECHNICAL DISTRICT 450016 The following sample(s) was/ were submitted and identified on behalf of the client as:

Sample Name : PVC TAPE

SGS Ref. No. : TP16-009285 -TJ

Date of sample received : 09 December, 2016

Testing Period : 09 December, 2016 to 21 December, 2016

Test result(s) : For further details, please refer to the following page(s)

Signed for and on behalf of SGS-CSTC Standards Technical Services (Tianjin) Co., Ltd.

______________________ Reabeca Zhou Approved Signatory

Page 2: EN60454-3-1.PDF

Test Report No. TSNEC1602189001 Date: 21 December, 2016 Page 2 of 14

Summary of Results:

No. Test Item Test Method Result Conclusion

1 Corrosive Sulfur

Resistance

BS EN 60454-2:2007

Section 7.5

Copper

rod(adhesive

side downward)

No

visible

staining /

Copper

rod(adhesive

side upward)

No

visible

staining

2 Dielectric

Strength

EN 60454-3-

1:1998+A1:2001 & BS EN

60454-2:2007 Section 17 &

IEC 60243-1:2013 Short-

time (Rapid-rise) Test

61.3 kV/mm Pass

3

Dielectric

Strength after

Humidity

Conditioning

EN 60454-3-

1:1998+A1:2001 & BS EN

60454-2:2007 Section 18 &

IEC 60243-1:2013 Short-

time (Rapid-rise) Test

63.6 kV/mm Pass

4

Low

temperature

properties

EN 60454-3-

1:1998+A1:2001 & BS EN

60454-2:2007 Section 9

Flexibility No cracking,

no unwinding Pass

Electric

breakdown

No

breakdown Pass

5 180º Peel

Strength

EN 60454-3-

1:1998+A1:2001 & BS EN

60454-2:2007 Section 11

Method A

2.0N/10mm Pass

Page 3: EN60454-3-1.PDF

Test Report No. TSNEC1602189001 Date: 21 December, 2016 Page 3 of 14

No. Test Item Test Method Result Conclusion

6

Adhesion to

backing at

low

temperature

With reference to EN

60454-3-1:1998+A1:2001

& BS EN 60454-2:2007

Section 12 & client’s

requirement

2.9N/10mm Pass

7 Flame test

EN 60454-3-

1:1998+A1:2001 & BS EN

60454-2:2007 Section 20

Flame retardant Pass

8 Length ASTM D1000-10 Section

30-32 Method A 20.7m /

9

Shear

adhesion to

backing

after liquid

immersion

EN 60454-3-

1:1998+A1:2001 & BS EN

60454-2:2007 Section 13

20.8N Pass

Page 4: EN60454-3-1.PDF

Test Report No. TSNEC1602189001 Date: 21 December, 2016 Page 4 of 14

No. Test Item Test Method Result Conclusion

10 Tensile Test

EN 60454-3-

1:1998+A1:2001 & BS EN

60454-2:2007 Section 8

Breaking

Strength

229N/10mm per

millimetre of

tape thickness

Pass

Elongation at

Break 255% Pass

11 Thickness

EN 60454-3-

1:1998+A1:2001 & BS EN

60454-2:2007 Section 4

0.128mm Pass

12 Width

EN 60454-3-

1:1998+A1:2001 & BS EN

60454-2:2007 Section 5

Method A

18.4mm /

Note: Pass : Meet the requirements;

Fail : Does not meet the requirements;

/ : Not Apply to the judgment.

Original Sample Photo:

Page 5: EN60454-3-1.PDF

Test Report No. TSNEC1602189001 Date: 21 December, 2016 Page 5 of 14

1. Test item: Corrosive sulfur resistance

Sample description: See photo

Test method: BS EN 60454-2:2007 Section 7.5

Test condition:

Copper rod diameter: 6 mm, length: 75 mm

Wind the copper rods(as follows)→100±2 ℃, 16 h

Test result(s):

Test item Test results

Corrosive sulfur resistance Copper rod(adhesive side downward) No visible staining

Copper rod(adhesive side upward) No visible staining

Note: Test specimens were cut from the sample.

Page 6: EN60454-3-1.PDF

Test Report No. TSNEC1602189001 Date: 21 December, 2016 Page 6 of 14

2. Test Item: Dielectric Strength

Sample Description: See photo

Test Method: EN 60454-3-1:1998+A1:2001 & BS EN 60454-2:2007 Section 17 & IEC 60243-1:2013 Short-time

(Rapid-rise) Test

Test Condition:

Precondition: 23 ± 2 ℃, 50 ± 5 % RH, 48 h

Thickness of specimen: 0.127 mm

Test condition: 23 ± 2 ℃, 50 ± 5 % RH

Surround medium: Air

Similar electrode: Electrode diameter: 6.4 mm

Frequency of voltage application: 50 Hz

Rate-of-rise: 500 V/s

Test Result:

Test Item Test Result

Requirement in EN

60454-3-

1:1998+A1:2001

Conclusion

Dielectric Strength 61.3 kV/mm ≥40 kV/mm Pass

Note: Test specimens were cut from the sample.

Page 7: EN60454-3-1.PDF

Test Report No. TSNEC1602189001 Date: 21 December, 2016 Page 7 of 14

3. Test Item: Dielectric Strength after Humidity Conditioning

Sample Description: See photo

Test Method: EN 60454-3-1:1998+A1:2001 & BS EN 60454-2:2007 Section 18 & IEC 60243-1:2013 Short-time

(Rapid-rise) Test

Test Condition:

Precondition: 23 ± 2 ℃, 93 ± 2 % RH, 24 h

Thickness of specimen: 0.132 mm

Test condition: 23 ± 2 ℃, 50 ± 5 % RH

Surround medium: Air

Similar electrode: Electrode diameter: 6.4 mm

Frequency of voltage application: 50 Hz

Rate-of-rise: 500 V/s

Test Result:

Test Item Test Result

Requirement in EN

60454-3-

1:1998+A1:2001

Conclusion

Dielectric Strength 63.6 kV/mm ≥35 kV/mm Pass

Note: Test specimens were cut from the sample.

Page 8: EN60454-3-1.PDF

Test Report No. TSNEC1602189001 Date: 21 December, 2016 Page 8 of 14

4. Test item: Low temperature properties

Sample description: See photo

Test method: EN 60454-3-1:1998+A1:2001 & BS EN 60454-2:2007 Section 9

Test condition:

Flexibility:

Precondition: -18 ℃, 3 h

Test temperature: -18 ℃

Bent angle: 180°

Mandrel diameter: 8 mm

Electric breakdown:

Precondition: After flexibility test→23±2 ℃, 4h→Immerse the bent portion in tap water, 23±2℃, 1h

Surround medium: Tap water

Test temperature: 23±2 ℃

Test voltage: AC, 1500 V

Electrification time: 1min

Test result(s):

Test item Test Result

Requirement in EN

60454-3-

1:1998+A1:2001

Conclusion

Flexibility No cracking, no

unwinding

No cracking, no

unwinding Pass

Electric breakdown No breakdown No breakdown Pass

Note: Test specimens were cut from the sample.

Page 9: EN60454-3-1.PDF

Test Report No. TSNEC1602189001 Date: 21 December, 2016 Page 9 of 14

5. Test Item: 180º Peel Strength

Sample Description: See photo

Test Method: EN 60454-3-1:1998+A1:2001 & BS EN 60454-2:2007 Section 11 Method A

Test Condition:

Specimen width: 18.4mm

Testing speed: 300mm/min

Lab Environmental Condition: (23±2)℃, (50±5)%RH

Test Result:

Test Item Test Result

Requirement in EN

60454-3-

1:1998+A1:2001

Conclusion

180º Peel Strength (to steel panel) 2.0N/10mm ≥1.8N/10mm Pass

Note: Test specimens were cut from the sample.

6. Test Item: Adhesion to backing at low temperature

Sample Description: See photo

Test Method: With reference to EN 60454-3-1:1998+A1:2001 & BS EN 60454-2:2007 Section 12 & client’s

requirement

Test Condition:

Precondition: -10℃, 2h → Prepare the specimen at -10℃ → -10℃, 17h → Take out and do the 180º Peel

adhesion test immediately

Specimen width: 18.4mm

Testing speed: 300mm/min

Lab Environmental Condition: (23±2)℃, (50±5)%RH

Test Result:

Test Item Test Result Client’s requirement Conclusion

Adhesion to backing at low

temperature 2.9N/10mm ≥1.5N/10mm Pass

Note: Test specimens were cut from the sample.

Page 10: EN60454-3-1.PDF

Test Report No. TSNEC1602189001 Date: 21 December, 2016 Page 10 of 14

7. Test Item: Flammability

Sample Description: See photo

Test Method: EN 60454-3-1:1998+A1:2001 & BS EN 60454-2:2007 Section 20

Test Condition:

Specimen width: 18mm

Metal wire diameter: 3.5mm

Test Result:

Specimen No. 1 2 3

Number of Flame

application 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5

Flame time after each

application (s) 1.0 0 0 0 1.0 0 2.1 0 1.0 1.0 1.0 0 0 1.0 0

Whether or not any

specimen continues to

flame longer than 60 s after

application of the gas flame

No No No

Whether or not any

specimen shows more than

25% of the indicator flag

burned away or charred

No No No

Whether or not any

specimen emits flaming or

glowing particles or flaming

drops at any time that ignite

the cotton

No No No

Judgment

a) Flame retardant. (See note 1)

b) Can’t convey flame along its length. (See note 2)

c) Can’t convey flame to combustible materials in its vicinity. (See note 3)

Requirement in EN 60454-3-1:1998+A1:2001: Flame retardant

Conclusion: Pass

Page 11: EN60454-3-1.PDF

Test Report No. TSNEC1602189001 Date: 21 December, 2016 Page 11 of 14

Note:

1. If the specimen shows less than 25 % of the indicator flag burned or charred (soot that can be

removed with a cloth or fingers and brown scorching is to be ignored), does not emit flaming or glowing

particles or flaming drops at any time that ignite the cotton on the burner, wedge, or floor of the

enclosure (flameless charring of the cotton shall be ignored) and continues to flame less than 60 s after

application of the gas flame, the tape shall be judged flame retardant.

2. If the specimen shows more than 25 % of the indicator flag burned or charred (soot that can be

removed with a cloth or fingers and brown scorching is to be ignored) after any of the five applications

of flame, the tape is to be judged capable of conveying flame along its length.

3. If the specimen emits flaming or glowing particles or flaming drops at any time that ignites the cotton on

the burner, wedge, or floor of the enclosure (flameless charring of the cotton shall be ignored), the tape

is judged capable of conveying flame to combustible materials in its vicinity.

4. Test specimens were cut from the sample.

Page 12: EN60454-3-1.PDF

Test Report No. TSNEC1602189001 Date: 21 December, 2016 Page 12 of 14

8. Test Item: Length

Sample Description: See photo

Test Method: ASTM D1000-10 Section 30~32 Method A

Test Condition:

Measured by digital balance

Lab Environment Condition: (23±2)℃, (50±5)%RH

Test Result:

Test Item Test Result

Length 20.7m

Note: Test specimens were cut from the sample.

9. Test Item: Shear adhesion to backing after liquid immersion

Sample Description: See photo

Test Method: EN 60454-3-1:1998+A1:2001 & BS EN 60454-2:2007 Section 13

Test Condition:

Precondition: Immerse in water, 23±2℃, 16h → Wipe off water, do the test after 5min

Adhesion area: 12×12mm2

Testing speed: 300mm/min

Lab Environmental Condition: (23±2)℃, (50±5)%RH

Test Result:

Test Item Test Result

Requirement in EN

60454-3-

1:1998+A1:2001

Conclusion

Shear adhesion to backing after

liquid immersion 20.8N ≥18N Pass

Note: Test specimens were cut from the sample.

Page 13: EN60454-3-1.PDF

Test Report No. TSNEC1602189001 Date: 21 December, 2016 Page 13 of 14

10. Test Item: Tensile Test

Sample Description: See photo

Test Method: EN 60454-3-1:1998+A1:2001 & BS EN 60454-2:2007 Section 8

Test Condition:

Specimen width: 18.4mm

Specimen thickness: 0.128mm

Testing speed: 300mm/min

Grip separation: 100mm

Lab Environmental Condition: (23±2)℃, (50±5)%RH

Test Result:

Test Item Test Result

Requirement in EN

60454-3-

1:1998+A1:2001

Conclusion

Breaking Strength

229N/10mm per

millimetre of

tape thickness

≥150N/10mm per

millimetre of

tape thickness

Pass

Elongation at Break 255% ≥125% Pass

Note: Test specimens were cut from the sample.

Page 14: EN60454-3-1.PDF

Test Report No. TSNEC1602189001 Date: 21 December, 2016 Page 14 of 14

11. Test Item: Thickness

Sample Description: See photo

Test Method: EN 60454-3-1:1998+A1:2001 & BS EN 60454-2:2007 Section 4

Test Condition:

Pressure: 54.4kPa

Nominal thickness: 0.13mm (Provided by client)

Lab Environmental Condition: (23±2)℃, (50±5)%RH

Test Result:

Test Item Test Result Client’s requirement Conclusion

Thickness 0.128mm 0.13±0.025mm Pass

Note: Test specimens were cut from the sample.

12. Test Item: Width

Sample Description: See photo

Test Method: EN 60454-3-1:1998+A1:2001 & BS EN 60454-2:2007 Section 5 Method A

Lab Environmental Condition: (23±2)℃, (50±5)%RH

Test Result:

Test Item Test Result

Width 18.4mm

Note: Test specimens were cut from the sample.

Appendix information: The above test was carried out by a SGS internal laboratory.

******** End of report********