Operating Instructions Position Switch type 07-2931-1 ***/**
BARTECGmbH Max-Eyth-Strae 16D-97980 Bad Mergentheim
Tel.: +49 7931 597-0Fax: +49 7931 597-119
Reservation Technical data subject to change without notice. Changes, errors andmisprints may not be used as a basis for any claim for damages.
1/7
Position switch without actuator Actuator
Explosion protection Technical data
Weightdepends on the model
Tightening torque
Actuator screws 0.9 Nm
Further technical informationTypes of contact, contact assignments andswitching examples: see page 5
Ex protection type
II 2G Ex d IIC T6II 2D Ex tD A21 IP66 T80 C
0044Certification
PTB 09 ATEX 1048 X
Ambient temperatureOperation: -20 C to +60 CStorage, transport: -20 C to +80 C
Approved for zones1/21 and 2/22
Cable entry
Description Technical data Technical data
Position switches are used wherever movableparts on machinery and systems have to bepositioned, controlled and monitored. Theycontrol and facilitate signal transmission inswitching gear or function as switches in regu-lating and control devices.
The flameproof encapsulated BARTEC positionswitches can be used in hazardous (potentiallyexplosive areas in Zones 1 and 2 in accor-dance with the certified explosion subgroupsIIA, IIB and IIC and the temperature class T6and in Zones 21 and 22 according to thecertified maximum surface temperature.
NOTE
See page 4 for the designations of the compo-nents in the position switch.
01-2
930-7
D0001-A.0
1-B
ARTECAdvertisingAgency-2
91427
E
Dimensions in mmEnclosure without actuators
ca. 103
60
1,5
30
SW 24
8
42,5
46
,3
17
5,
5
5,5
12,5
Protection classIP 66 (IEC 60529)
Weightca. 160 g
Mechanical switching unitRated insulation voltage400 VRated operating voltage/currentAC 15:400 V/4 AAC 15: 24V and 240 V/6 ADC 13: 24V/3 ADC 13:110 V/0.8 A
DC 13:220 V/0.3 ARated impulse strength4 kV ACSwitching rateup to 6000/h depending on typeService lifeelectrical: depending on loadmechanical: max. 106switching cycles (de-pending on actuation angle/speed)
Electronic switching unitRated voltageup to 30 V DCRated operating voltage/currentDC 12 V/0.015 ADC 24V/0.018 ADC 30 V/0.019 A
Tightening torquesLid screws: max. 0.9 NmPressure screw: 5 Nm
Enclosure /plunger materialInjection moulding made of thermoplastic
Pressure screwM 20 x 1.5
Cable diameter 5 to 8.4 mmWasher:Outside diameter 18.3 mmInside diameter 8.7 mmThickness 1 mm
Sealing ring:(fitted, without marking)Outside diameter 18.5 mmInside diameter: 8.4 mmHeight: 13 mm
Cable diameter 8 to 12 mmWasher:Outside diameter 18.3 mmInside diameter of 12.2 mmThickness 1 mm
Sealing ring:(with marking 20S)Outside diameter 18.5 mmInside diameter of 11.7 mmHeight 13 mm
NOTE
For a picture of the cable entry see also theassembly illustrations on page 4.
-
8/11/2019 En Position Switch 07-2931
2/7
Operating Instructions Position Switch type 07-2931-1 ***/**
BARTECGmbH Max-Eyth-Strae 16D-97980 Bad Mergentheim
Tel.: +49 7931 597-0Fax: +49 7931 597-119
Reservation Technical data subject to change without notice. Changes, errors andmisprints may not be used as a basis for any claim for damages.
2/7
01-2
930-7
D00
01-A.0
1-B
ARTECAdvertisingAgency-2
91427E
Safety Instructions
Incorrect installation can cause mal unctioningand the loss of protection against explosions.
The position switch may be connected andassembled only by qualified personnel who areauthorised and trained to assemble elec rical
devices in hazardous (poten ially explosive)areas.
The position switch with actuation may neverbe operated without the actuator. Only usesealing rings and washers that suit the conduc-tor diameter. Utilisation without a sealing ring /washer or with an incorrect sealing ring /washer will lead to the loss of protection classand explosion -proofness. The fully installedposition switches must close tightly (observingtorques).
Do not open position switches if the atmos-phere is explosive. Always disconnect theactuator from voltage before assembly
/disassembly.Utilisation in areas other than those specified orthe alteration of the product by anyone otherthan the manu acturer will exempt BARTECfrom liability for defects or from any furtherliability.
The generally applicable statutory rules andother binding directives relating to workplacesafety, accident prevention and environmentalprotection must be adhered to.
The position switch may be used only if it isclean and free of any damage. The positionswitch may not be used as a mechanical stop.
Standards conformed to
EN 60079-0:2006EN 60079-1:2007EN 61241-0:2006EN 61241-1:2004EN 60947-5-1:2004EN 61000-4-2:2001EN 61000-4-3:2001EN 61000-4-4:2002EN 61000-4-5:2001EN 61000-4-6:2001
Marking
Particularly important points in these instruc-tions are marked with a symbol:
DANGER
Non-observance leads to death or seriousphysical injury. The necessary safety measuresmust be implemented.
CAUTION
Warning of damage to property and financialand penal disadvantages (e.g. loss of guaran-tee rights, liability claims etc.).
ATTENTION
Important instructions and information onpreventing disadvantageous behaviour.
NOTE
Important instructions and information oneffective, economical and environmentallycompatible handling.
Assembly and CommissioningATTENTION
Only authorised and qualified personnel maydo any of the assembly, disassembly, installa-tion and commissioning work.
CAUTION
The relevant installation and operating regula-tions must be observed when setting up oroperating explosion-proof electric systems.
Assembly/Disassembly
ATTENTIONIf the position switches / actuators are stored ina cold environment, condensation may occur inthe site of installation. Only mount componentswithout condensation.Dust deposits exceeding 5 mm must be re-moved.
At least two 5-mm-diameter screws must beused for mounting the position switch.
A strain relief device (e.g. SILVYN-RKS cableclamp from Lapp or equivalent) must be fittedapprox 50 mm after the screwed connection.Observe the minimum bending radius for thecable.
NOTE
The assembly steps are illustrated on page 4.
Installation
DANGER
The supply cable must be selected so that itsatisfies the thermal and mechanical require-ments in the area of use. It is important not todamage the core insulation during installation.
Only the conductors listed in the table on page3 may be used.
When shielded conductors are used, thesheathing must be cut off flush with the oute
jacket.
When connecting multi-wire or fine-strandedconductors, prepare the conductor ends first.
Supply cable, cross-section:0.75 - 2.5 mm2 (one-wire)0.75 - 1.5 mm2 (fine-wired, wire end ferrule)
DANGER
Always use the sealing ring and washer in-cluded in the scope of supply that suit theconductor diameter.Only use parts included in the scope of supply.Never use cable entries or parts from anothemanufacturer.
The max. torque for the lid fixing screws is 0.9Nm.
Commissioning
Before commissioning check that:
the device has been installed in compli-ance with regulations
the device is not damaged there is no foreign matter in the device
the junction box is clean the connection has been establishedproperly
the cable has been run in properly all screws are tightened securely the cable entry, sealing ring and sealings
have been fitted correctly the flameproof enclosure is not damaged
Switching point setting
CAUTION
Do not open position switches in an explosiveatmosphere.
The switching point in the elec ronic switchingunit can be set in the range from 0.5 mm to 5.5mm:
Loosen the lid screws and take off the lid Move the actuator to the switching position Press the set button on the switching unit
for 1 s LED must flash with a high frequency Put on the lid, tighten the lid screws
-
8/11/2019 En Position Switch 07-2931
3/7
Operating Instructions Position Switch type 07-2931-1 ***/**
BARTECGmbH Max-Eyth-Strae 16D-97980 Bad Mergentheim
Tel.: +49 7931 597-0Fax: +49 7931 597-119
Reservation Technical data subject to change without notice. Changes, errors andmisprints may not be used as a basis for any claim for damages.
3/7
Operation
DANGER
The position switch may be operated onlywithin the technical limits that apply to it (seethe Explosion Protection and Technical Data
sections).
Maintenance
The operator of the position switch must keep itin an orderly condition, operate it correctly,monitor it and clean it regularly. The enclosure,sealings and cable entry must be checkedregularly for cracks and damage.
NOTE
Dirty enclosures/actuators can be cleaned withdry and clean compressed air.
Fault clearanceDANGER
If the conductor to the position switch is re-placed, a new sealing ring and a new washemust be inserted too.
Always use a sealing ring and washer that suithe conductor diameter.
The position switch is defective if the switchingunit does not perform the switching function orthe actuator does not activate the switchingunit any longer. Defective position switchescannot be repaired; they must be replaced.Only original parts (e.g. sealings, sealing rings,washers, pressure screw) may be used asreplacements.Defective actuators can be taken off the posi-ion switches and replaced by functioning
actuators of the same type.
DANGER
A new sealing must be inserted whenever theactuator is replaced.
Accessories, Spare Partson request
Disposal
The components in the position switch and theactuator contain metal and plastic parts.For that reason the statutory requirements forelectronic scrap must be adhered to whendisposing of them (e.g. disposal by an ap-proved disposal company).
Service Address
BARTEC GmbHMax-Eyth-Strae 16D-97980 Bad MergentheimTel.: +49 7931 597-0Fax: +49 7931 597-119
Supply cables to be used
DANGER
Only the following supply cables may be used. Equivalent conductors (i.e. from other manufacturers) are permitted.
Cable Max. ambient temperatur Min. conductor cross-section
H07RN-F / A07RN-F 40 C 0.75 mm2
H05RN-F / A05RN-F 40 C 0.75 mm2
H05VV-F / A05VV-F 40 C 0.75 mm2
lflex (shielded also) 40 C 0.75 mm2Unitronic-LiyCY 40 C 0.75 mm2
H05VV-F / A05VV-F 60 C 1.5 mm2
lflex (shielded also) 60 C 1.5 mm2
NSSHu 60 C 1 mm2
Ozoflex plus H07RN-F 60 C 1 mm2
H05GG-F 60 C 1 mm2
01-2
930-7
D0001-A.0
1-B
ARTECAdvertisingAgency-2
91427E
Radox (shielded also) 60 C 1 mm2
-
8/11/2019 En Position Switch 07-2931
4/7
Operating Instructions Position Switch type 07-2931-1 ***/**
BARTECGmbH Max-Eyth-Strae 16D-97980 Bad Mergentheim
Tel.: +49 7931 597-0Fax: +49 7931 597-119
Reservation Technical data subject to change without notice. Changes, errors andmisprints may not be used as a basis for any claim for damages.
4/7
Components in the Position Switch
1 Lid
2 Switching unit
3 Lid sealing
4 Sealing on the actuator side
5 Actuator with screws (exam-ple)
6 Enclosure
7 Sealing ring
8 Washer
1
5
2 4
6789
3
9 Pressure screw
Assembly
2
4 x
3
5
4 x
1
**)
*)
max. 0,9 Nm
4
6 mm
40 mm
01-2
930-7
D0001
-A.0
1-B
ARTECAdvertisingAgency-2
91427E
Explanations
*) The sealing ring for large conductor diameters is marked 20S.
**) Only when changing or turning the actuator. Adjustment and insertion depend on the actuator being used.
-
8/11/2019 En Position Switch 07-2931
5/7
-
8/11/2019 En Position Switch 07-2931
6/7
Operating Instructions Position Switch type 07-2931-1 ***/**
BARTECGmbH Max-Eyth-Strae 16D-97980 Bad Mergentheim
Tel.: +49 7931 597-0Fax: +49 7931 597-119
Reservation Technical data subject to change without notice. Changes, errors andmisprints may not be used as a basis for any claim for damages.
6/7
LED Mode of Operation
A lamp tube for the LED display for the switching unit (A) is fitted into the lid. This display shows the operating status of the switching unit.
A
Types 07-2931-1411/** and 07-2931-1421/**
The electronic position switches have a self-test function. The Q1 and Q2 outputs are constantly monitored for overload, short circuit against 0 V and short circuitagainst +Ue. The LED display in the lid indicates the operating status as well as the plunger actuation and set button:
Plunger not actuated Plunger actuated Set button actuated,new operating position accepted
Fault in the device
1x 2x 3x
Types 07-2931-1500/** and 07-2931-1600/**
The electronic position switches have a self-test function. The Q1 and Q2 outputs are constantly monitored for overload, short circuit against 0 V and short circuitagainst +Ue. The LED display in the lid indicates the operating status:
Type 07-2931-1500/** Type 07-2931-1600/**
Normal case:Q1 = 4 - 20 mAQ2 Ue
Fault:Q1 = 0 mAQ2 = 0 V
Normal case:Q1 = 0 - 10 VQ2 Ue
Fault:Q1 = 0 VQ2 = 0 V
01
-2930-7
D0001-A.0
1-B
ARTECAdvertisingAgency-2
91427E
-
8/11/2019 En Position Switch 07-2931
7/7
Operating Instructions Position Switch type 07-2931-1 ***/**
BARTECGmbH Max-Eyth-Strae 16D-97980 Bad Mergentheim
Tel.: +49 7931 597-0Fax: +49 7931 597-119
Reservation Technical data subject to change without notice. Changes, errors andmisprints may not be used as a basis for any claim for damages.
7/7