Transcript of EMPYREAN ALPHA-1 - Malvern Panalytical Alpha1 bro… · The Empyrean Alpha-1 is a member of Malvern...

Page 1: EMPYREAN ALPHA-1 - Malvern Panalytical Alpha1 bro… · The Empyrean Alpha-1 is a member of Malvern Panalytical’s family of Empyrean X-ray diffraction systems. In the Alpha-1, a

EMPYREAN ALPHA-1Unrivalled data quality from a laboratory XRD system

Page 2: EMPYREAN ALPHA-1 - Malvern Panalytical Alpha1 bro… · The Empyrean Alpha-1 is a member of Malvern Panalytical’s family of Empyrean X-ray diffraction systems. In the Alpha-1, a

3

PreFIX: TRUE FLEXIBILITY FOR ALL OF YOUR CRYSTALLOGRAPHIC NEEDSThe key to the Alpha-1’s flexibility is its ingenious use of Malvern Panalytical’s PreFIX (Pre-aligned Fast Interchangeable X-ray) technology. This kinematic mounting system is applied to optics, stages and even the tube housing, and allows the diffractometer to be reconfigured in minutes without realignment.

In five minutes or less, the high-resolution Alpha-1 diffractometer becomes a multipurpose diffraction system ready to tackle a variety of analytical challenges.

ENGINEERED TO BE THE BEST The Empyrean Alpha-1 is a member of Malvern Panalytical’s family of Empyrean X-ray diffraction systems. In the Alpha-1, a unique symmetric Johansson monochromator provides data with unrivalled resolution, excellent peak symmetry, and ultra-low background - perfect for structural analysis needs.

Superior Johansson monochromator design

Whereas some Johansson monochromators use an asymmetrically cut crystal, Malvern Panalytical employs a symmetrically cut, curved Ge (111) crystal to deliver superior resolution and spectral purity.

The Kα1 X-ray beam is concentrated on the virtual line focus position of the Bragg-Brentano geometry.

Malvern Panalytical’s unique monochromator positioning motor allows easy fine-tuning of the monochromator alignment without the need for outdated practices which compromise the safety of the system.

Copper or cobalt X-rays – your choice

The Alpha-1 system can be set up with either a copper (Cu) or a cobalt (Co) X-ray tube, depending on the type of materials analyzed most frequently. For iron and cobalt bearing materials, the use of Co radiation instead of Cu results in higher peak intensities and therefore a much improved peak-to-background ratio when analyzing these materials.

2

Conclusion:The Empyrean Alpha-1 is ideal for: • solving structures from powder data• searching for polymorphic phases where peak overlap is a hinderance•  studying nanomaterial peak profiles to extract crystallite size, dislocation densities, and residual

stress• preparing materials for synchrotron beam time

2theta [deg.]21 21.50

Inte

nsity

[cou

tns]

2000

0

4000

6000

0.026°

LaB6

Figure 1. SRM660a lanthanum boride plotted on square root scale, exhibiting an exceptionally low (32 counts) and flat background, and an unsurpassed resolution of 0.026° FWHM of the first reflection.

Figure 2. Measurement of LaB6 using cobalt Kα1 radiation. The FWHM is as low as 0.027° when extrapolated to 2θ = 20°.

Page 3: EMPYREAN ALPHA-1 - Malvern Panalytical Alpha1 bro… · The Empyrean Alpha-1 is a member of Malvern Panalytical’s family of Empyrean X-ray diffraction systems. In the Alpha-1, a

Grovewood Road, Malvern, Worcestershire, WR14 1XZ, United Kingdom

Tel. +44 1684 892456Fax. +44 1684 892789

Lelyweg 1, 7602 EA Almelo, The Netherlands

Tel. +31 546 534 444Fax. +31 546 534 598

[email protected]

MALVERN PANALYTICAL

WHY CHOOSEMALVERN PANALYTICAL? Malvern Panalytical provides the global training,

service and support you need to continuously drive your analytical processes at the highest level. We help you increase the return on your investment with us, and ensure that as your laboratory and analytical needs grow, we are there to support you.

Our worldwide team of specialists adds value to your business processes by ensuring applications expertise, rapid response and maximum instrument uptime.

• Local and remote support

• Full and flexible range of support agreements

• Compliance and validation support

• Onsite or classroom-based training courses

• e-Learning training courses and web seminars

• Sample and application consultancy

We are global leaders in materials characterization, creating superior, customer-focused solutions and services which supply tangible economic impact through chemical, physical and structural analysis.

Our aim is to help you develop better quality products and get them to market faster. Our solutions support excellence in research, and help maximize productivity and process efficiency.

Malvern Panalytical is part of Spectris, the productivity-enhancing instrumentation and controls company.

www.spectris.com

SERVICE & SUPPORT

Dis

clai

mer

: Alth

ough

dili

gent

car

e ha

s be

en u

sed

to e

nsur

e th

at th

e in

form

atio

n in

this

mat

eria

l is

accu

rate

, not

hing

her

ein

can

be c

onst

rued

to im

ply

any

repr

esen

tatio

n or

war

rant

y as

to th

e ac

cura

cy, c

orre

ctne

ss o

r com

plet

enes

s of

this

info

rmat

ion

and

we

shal

l not

be

liabl

e fo

r err

ors

cont

aine

d he

rein

or f

or d

amag

es in

con

nect

ion

with

the

use

of th

is m

ater

ial.

Mal

vern

Pan

alyt

ical

rese

rves

the

right

to c

hang

e th

e co

nten

t in

this

mat

eria

l at a

ny ti

me

with

out n

otic

e.

Copy

right

: © 2

019

Mal

vern

Pan

alyt

ical

. Thi

s pu

blic

atio

n or

any

por

tion

ther

eof m

ay n

ot b

e co

pied

or t

rans

mitt

ed w

ithou

t our

exp

ress

writ

ten

perm

issi

on.

PN12

074

www.malvernpanalytical.com