EMI/EMC TEST FACILITY - ERDA635351447175011466.pdf&realfile=emiemc.pdf · EMI/EMC TEST FACILITY ......

4
FOUR DECADES OF SERVICE TO ELECTRICAL UTILITIES & INDUSTRIES FOUR DECADES OF SERVICE TO ELECTRICAL UTILITIES & INDUSTRIES ELECTRICAL RESEARCH AND DEVELOPMENT ASSOCIATION (Accredited by NABL, Govt. of India) (Accredited by NABL, Govt. of India) EMI/EMC TEST FACILITY (10M- SEMI ANECHOIC CHAMBER)

Transcript of EMI/EMC TEST FACILITY - ERDA635351447175011466.pdf&realfile=emiemc.pdf · EMI/EMC TEST FACILITY ......

Page 1: EMI/EMC TEST FACILITY - ERDA635351447175011466.pdf&realfile=emiemc.pdf · EMI/EMC TEST FACILITY ... (EMI) emission and susceptibility characteristics of electronic, ... RE 102 Radiated

FOUR DECADES OF SERVICE TO ELECTRICAL UTILITIES & INDUSTRIESFOUR DECADES OF SERVICE TO ELECTRICAL UTILITIES & INDUSTRIES

ELECTRICAL RESEARCH ANDDEVELOPMENT ASSOCIATION

(Accredited by NABL, Govt. of India)(Accredited by NABL, Govt. of India)

EMI/EMC TEST FACILITY(10M- SEMI ANECHOIC CHAMBER)

Page 2: EMI/EMC TEST FACILITY - ERDA635351447175011466.pdf&realfile=emiemc.pdf · EMI/EMC TEST FACILITY ... (EMI) emission and susceptibility characteristics of electronic, ... RE 102 Radiated

ERDA's EMI/EMC Laboratory: A Capability Profile

Laboratory RecognitionsIntegrated Headquarters, Ministry of Defense (Navy) for EMI/EMC testing of Naval Equipment

National Accreditation Board for Testing and Calibration Laboratories (NABL)

Bureau of Indian Standards (BIS)

Major EMI/EMC Certification Test ServicesI) As Per Department of Defense (DoD) Test Codes:

Capability exists for conducting tests as per MIL-STD-461E/F. These standards establish interface and are associated for the verification of requirements for the control of electromagnetic interference (EMI) emission and susceptibility characteristics of electronic, electrical and electromagnetic equipment and subsystems designed or produced for the use by activities and agencies of the Department of Defense (DOD). Such equipment and subsystems may be used independently or as an integral part of other subsystems or systems.

Modern electrical/electronic equipment & instrumentation make use of ever increasing sophisticated electronics, making

them prone to malfunctioning/misoperation due to issues related to electromagnetic interference (EMI) /electromagnetic

compatibility (EMC) which can either permanently damage the equipment or can even cause damage to the larger system

in which the equipment may be embedded/networked. To ensure that such failures do not occur, stringent EMI/EMC

compatibility test codes & procedures have been developed by the relevant National/ International standards as per which

all electrical/electronic products must be evaluated to meet the required minimal specified level of EMI/EMC compliance.

To enable the industry to have their electrical/electronic products tested for EMI/EMC compliance requirements, ERDA has

set up a sophisticated state-of-the-art 10 meter semi-anechoic chamber and the test facilities as per IS/IEC and MIL

standards. Relevant highlights of this laboratory are as below:

CE 101 Conducted Emission, power leads: 30 Hz to 10 kHz

CE 102 Conducted Emission, power leads: 10 kHz to 10 MHz

RE 102 Radiated Emission-electric field: 10 kHz to 18 GHz

CS 101 Conducted Susceptibility, power leads: 30 Hz to 150 kHz

CS 114 Conducted Susceptibility: bulk cable injection: 10 kHz to 200 MHz

RS 103: Radiated Susceptibility: electric field- 10 kHz to 18 GHz

CS 115 Conducted Susceptibility bulk cable injection impulse excitation

CS 116 Conducted Susceptibility: Damped sinusoid transients, cable & power leads: 10 kHz to 100 MHz

RS 101 Radiated Susceptibility, magnetic field, 30 Hz to 100 KHz

RE 101 Radiated emission, magnetic field, 30 Hz to 100 KHz

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

I ) As Per Various Commercial Test Codes:I

Radio Interference / Disturbance Measurement

Electrical Fast Transient/Burst Immunity test

Electrostatic Discharge Immunity test

Radiated, Radio Frequency, Electro- Magnetic Field Immunity test up to 6GHz

Immunity to Conducted Disturbances, Induced by Radio Frequency Fields

Surge Immunity test

1.

2.

3.

4.

5.

6.

CISPR 14, CISPR 22, CISPR 11,CISPR 15

IEC 61000-4-4

IEC 61000-4-2

IEC 61000-4-3

IEC 61000-4-6

IEC 61000-4-5

Page 3: EMI/EMC TEST FACILITY - ERDA635351447175011466.pdf&realfile=emiemc.pdf · EMI/EMC TEST FACILITY ... (EMI) emission and susceptibility characteristics of electronic, ... RE 102 Radiated

Major Instrumentation & Equipment

EMI Test Receivers

Artificial Mains Network

Signal Generators

Power Amplifier

Antenna

Absorbing Clamp

Isotropic E Field Probe

1.

2.

3.

4.

5.

6.

7.

9 kHz to 2.75 GHz & 20Hz to 26.5 GHz

100 A, 9KHz to 30MHz

9KHz to 1.1 GHz, 1 GHz to 22 GHz

10kHz to 250MHz, 500W

10kHz to 18GHz

30MHz to 1000MHz

10KHz to 1GHz, 800V/m

10KHz to 40GHz

0.2GHz to 1GHz, 250W

1GHz to 6GHz, 75W/45W

6GHz to 18GHz, 4W

GTEM Cell – DC to 20GHz Pulse Generator Transient Pulse Generator

ESD (0.2kV to 30kV)CDN (150KHz to 230MHz)EFT (200V to 4.4kV)

Partial List of Products Tested for EMI/EMC Compliance?Energy Meters, CFLs, Electronics Ballasts, RCCBs & RCBOs?Relays (Feeder Protection Over Current & Earth Fault

Relay, High Impedance Relay, Directional Over Current Protection Relay, Trip Circuit Supervision Relay, Voltage Monitoring Relay, Digital Line Monitoring Relay)

?Timers?LED Based 3 Line Passenger Information Display System?65 kW Permanent Magnet Frequency Converter

Controller. ?IGBT Based Auxiliary Converter

?Bridge Console for Steering Gear System?Hydraulic Power Pack- Control Panel?Assemblies for Rocket Launcher?VDSL – Ethernet Modem?Control Panel for Window Wiper with RCU (Remote

Control Unit)?Tube Light Fitting, Weather Deck Light Fitting &

Pendant Light Fitting?Air Conditioners?150 KVA UPS System

Page 4: EMI/EMC TEST FACILITY - ERDA635351447175011466.pdf&realfile=emiemc.pdf · EMI/EMC TEST FACILITY ... (EMI) emission and susceptibility characteristics of electronic, ... RE 102 Radiated

?Starter/Control Panel for Refrigeration Plant (P-25)?ECS (Electric Control System) for Air Inflation System?15 KVA & 40 KVA Rotary Converter?Squirrel Cage Induction Motor with EM Brake?Control Panel for 3 Dimensional Mixer?S-Line Automatic Colorant Dispenser

?Alarm Annunciator?Gunner Console?Power Distribution Unit?Yarn Winding Machine

Accreditations & Recognitions

? Intertek (ASTA) for Switchgear, Cables & Transformers.? Underwriters' Laboratories (UL) for Certification Testing of Switchgear Products.? TÜV Rheinland (India) Pvt. Ltd.? Certification after Recognition of Agent's Testing (CARAT), TÜV-PS, Germany.

?National Accreditation Board for Testing & Calibration Laboratories (NABL) Government of India.

?Bureau of Indian Standards (BIS).

?Department of Atomic Energy (DAE), Government of India for LOCA Qualification and Seismic testing of electrical equipment.

?Bureau of energy efficiency for standards & labeling program for motors & pumps, geysers, refrigerators, lamps, transformers etc.

?Department of Scientific & Industrial Research (DSIR), Government of India.

?Gujarat Electricity Regulatory Commission, Madhya Pradesh Electricity Regulatory Commission and Rajasthan State Electricity Regulatory Commission for Energy Meters.

?Director of boilers, Government of Gujarat.

?Charity commissioner, Government of Maharashtra.

?Bureau of Energy Efficiency (BEE), Petroleum Conservation Research Association (PCRA), Gujarat Energy Development Agency(GEDA), Maharashtra Energy Development Agency (MEDA), Office of Chief Electrical Inspector, Government of Gujarat,

?Energy Management Centre (EMC), Kerala in their respective jurisdictions for Energy Audit.

?Directorate General - Factory Advice Service and Labor Institute (DGFASLI), Mumbai for increased safety motors.

?Petroleum Explosive & Safety Organization (PESO).

?Well Known Remnant Life Assessment Organization under Indian Boiler Regulations, 1950.

?Integrated Headquarters, Ministry of Defense (Navy) for EMI/EMC testing of Naval Equipment in Western Region.

Main Laboratory Complex

Tel. +91(0265) 2642942, 2642964, 2642377,

3043128-3043131, Fax: +91 (0265) 2638382

[email protected] | [email protected]

www.erda.org

ERDA Road, GIDC, Makarpura, Vadodara–390 010, India

ERDA is Accredited / Recognized as under:

International Accreditations/Recognitions

National Accreditations/Recognitions